WHITE PAPER
Molex Premise Networks
CHOOSING THE RIGHT HORIZONTAL CABLING SYSTEM
FOR HEALTHCARE ENVIRONMENTS
Samuel Huber, Global Product Manager
EXECUTIVE
SUMMARY
Installation of a cabling system in healthcare facilities involves
consideration of many factors. The healthcare field provides one of the
most demanding environments for a structured cabling system. Facilities
are designed to operate for 50 years or longer. Healthcare facilities have
many sources of electromagnetic interference (EMI) and radio frequency
interference (RFI) such as medical equipment, wireless communications,
and generators that can significantly impact the performance of an
Unshielded Twisted Pair (UTP) structured cabling system.
Infection control risk procedures and the nature of the healthcare
environment place many restrictions on how and when changes to
installed cabling can proceed. Recabling a healthcare facility can cost 4
to 5 times the initial installation cost due to the environment of working
in a 24/7 healthcare facility.
IP convergence of Voice, Paging, Security, and Building Automation
Systems are adding to the diversity of systems structured cabling
must support. Patient Monitoring and Interactive Patient Systems are
continually increasing in sophistication. Applications running over
healthcare networks such as Picture Archiving and Communication
Systems, laboratory and radiological information, and Physician
Order Entry systems require significant bandwidth. Adoption and
implementation of Power over Ethernet (POE) devices increases the
temperature of the cabling system which adversely affects performance.
Adoption of 10GBase-T Ethernet is rapidly increasing and is expected to
be the standard for the foreseeable future in healthcare facilities.
All of these factors point toward adoption of Category 6A shielded cable
as the best solution when installing horizontal copper cable for your
network infrastructure in healthcare facilities.
“Rapid adoption of
10GBase-T....over
the next few years”
10GBase-T Adoption; Supports the Installation of Category 6A
Cabling
A research report issued by The Linley Group (www.linleygroup.com)
forecasts more than 2.7 million ports of 10GBase-T to ship in 2012
compared to the 182,000 ports shipped in 2011. The Linley Group’s
forecast shows a rapid increase in adoption of 10GBase-T for several
different types of 10-Gbit/sec Ethernet applications over the next few
years with 10GBase-T expected to become the most popular 10G
application in 2014.
The Dell’Oro Group reports a similar increase in adoption of 10GBase-T.
The Controller and Adapter 5-Year Forecast Report states that 10-Gbit/
sec devices will grow at a compound annual growth rate of 33 percent
over the next five years and exceed shipments of 1-Gbit/sec measured
by ports in 2014. Adoption of Category 6A cable provides the foundation
of a 10Gbase-T capable network that lower capacity Category 6 cable
cannot support.
1
2
Healthcare Applications; Supports the Installation of Category
6A Cabling
The increasing adoption and use of electronic health information is
contributing to a massive increase in traffic across healthcare networks.
File sizes of digital x-ray images, MRI images and CT scans can reach 30
Gigabytes. Adoption of 10 Gigabit Ethernet can decrease transmission
times by 90%. A 30 Gigabyte file that takes 4 minutes to transmit at
1 Gigabit / second will take only 24 seconds at 10 Gigabits / second.
Quicker transmission of medical images improves the productivity of the
medical staff and contributes to improved patient outcomes. Adoption
of Category 6A cable ensures the lowest transmission times across all
channel lengths. The following table demonstrates the difference in
transmission times for the same file across different categories of cable.
Cable Cable Speed Transmission Time- 30 Gb file
Category 5e 100 Megabits / second 40 minutes
Category 6 1 Gigabit / second 4 minutes
Category 6A 10 Gigabits / second 24 seconds
IP convergence is also becoming a reality. Multiple cable systems will
be consolidated on the structured cabling to support applications such
as AV systems, facility controls, and patient monitoring systems. The
increase in the diversity of applications on the cable plant suggests the
most robust and longest lifespan cable should be installed to minimise
disruption of operations. The adoption of Category 6A cable supports this
dynamic.
Infection Control Impacts on Structured Cabling; Supports the
Installation of Category 6A Cabling
Infection control is taking on increasing importance as the scope of
Healthcare Associated Infections (HAI) has become known. A 2009 paper
by the United States Centre for Disease Control and Prevention (CDC)
estimated the total cost for HAI in the year 2007 to be between 28
and 33 billion dollars. About 10% of patients acquire an infection after
admission, according to the CDC, resulting in over 1.7 million HAIs.
Approximately one-third of all hospital infection threats are airborne. To
reduce the potential of airborne HAIs, Infection-control measures in a
hospital environment include stringent regulations to contain airborne
particles when removing ceiling tiles or other access to the plenum space
is required. When performing moves, adds, or changes (MACs) to cable
“A 30 Gigabyte file
that takes 4 minutes
to transmit at 1
Gigabit / second will
take only 24 seconds
at 10 Gigabits /
second”
3
“Shielded cabling
will minimise or
eliminate the
negative effects of
EMI on the network”
located in a plenum, the access areas to the plenum must be enclosed in
a tent or the entire area around the access space may require isolation
from the rest of the floor to prevent the spread of airborne contaminants.
In administrative and non-patient service areas where healthcare
operations are not 24/7, work can be done after hours to reduce the
impact on facility operations. In areas where operations occur 24/7,
patient care and activities may be impacted and downtime for rooms
and equipment connected to the cable plant may need to be scheduled.
In either case, complying with infection control procedures will add time
and cost to MACs for structured cabling. Installing the highest-performing
cabling up front allows for the longest possible life cycle of the cable
plant and minimises the effect on patient care. Adoption of Category 6A
cable supports the longest cable lifespan.
EMI in the Healthcare Environment; Supports the Installation of
Category 6A Shielded Cabling
The adoption and use of technology in healthcare creates an
environment full of electromagnetic interference (EMI). EMI is generated
from diagnostic and radiology equipment, wireless networks, and many
other sources. This results in performance degradation on the network.
Some of these devices in turn may be affected by EMI generated from
the structured cabling. The TIA-1179 Healthcare Cabling standard
recognizes the potential effects of EMI and suggests additional measures
including isolation from or routing of cables around equipment capable of
generating EMI. In addition TIA-1179 suggests testing cable performance
while equipment is operating. Shielded cabling will minimise or eliminate
the negative effects of EMI on the network as well as protect equipment
from EMI generated by the network. Shielded cable includes a foil
sheath around each wire pair that shields the cable from external EMI
from other cables as well as other devices such as medical equipment
that generates EMI. The benefits and advantages of using shielded
cabling increases as the use of EMI generating equipment increases.
Power over Ethernet; Supports the Installation of Category 6A
Shielded Cabling
The IEEE 802.3at-2009 PoE standard, commonly known as PoE Plus,
provides up to 25.5 W of power to a PoE device over a 4 pair cable.
PoE Plus provides the capability for many more devices such as LCD
displays, door access controls, pan-tilt-zoom cameras, and biometric
sensors to receive power over the network. PoE allows for convergence
of many systems that previously required separate cable systems to the
structured cable system used by the network.
4
“The TIA standard
addresses insertion
loss by de-rating
the cable as the
temperature of the
cable increases.”
Delivering power via the cable causes a temperature rise within the
cabling, which can result in increased insertion loss and potentially
reduce network performance. The TIA standard addresses insertion loss
by de-rating the cable as the temperature of the cable increases. As can
be seen in the following graph, C6A shielded cable is de-rated less than
unshielded cable. This allows shielded cable to support longer channels
as temperatures and/or provide additional headroom on the channel.
TIA De-rating for Different Temperatures
Maximum Horizontal Cable Length (m)
Temperature (˚C)
The superior performance of Category C6A shielded cable over
unshielded cable at higher temperatures makes supporting POE and IP
convergence easier.
TIA-1179 Recommendations; Supports the Installation of
Category 6A Cabling
The TIA-1179 Healthcare Facility Telecommunications Infrastructure
Standard accounts for the special needs and requirements presented in a
healthcare environment. The topics discussed in this paper factored into
the recommendations contained in TIA-1179. Following are a summary of
recommendations that impact the choice of cabling.
•	 Category 6A cable is recommended for new construction to allow for
the longest possible life cycle. This is consistent with the TIA 942 and
IEC 24764 Data Centre standards.
65
70
75
80
85
90
95
20 25 30 35 40 45 50 55 60
Cat 6A UTP
Cat 6A F/UTPShielded
5
“Shielded cable
eliminates the need
to test for AXT”
•	 Enclosed pathways for cable should be considered in air-handling
spaces to meet infection control requirements.
•	 Design cabling systems to support the longest possible lifespan to
support the bandwidth requirements and mission critical nature of
data transmission within healthcare facilities.
Advantages of Shielded Shielded vs. Unshielded UTP Cable
Previous sections have discussed the advantage shielded cable has
over UTP cable with respect to superior EMI performance, superior
performance in high temperature environments, and elimination of signal
radiation from the cable. In addition, shielded cable offers additional
advantages.
•	 Reduced Outer Diameter for shielded cable compared to unshielded cable
The smaller diameter of shielded cable allows for more cables in
each pathway or a reduction in the size of the pathway for the same
number of cables.
•	 Elimination of Alien Cross Talk (AXT) testing
Shielded cable eliminates the need to test for AXT. This reduces the
cost and time required for testing of the cable plant. UTP cabling
requires extensive testing for AXT.
•	 Ability to mix different categories of cable in the same pathway
Category 6A Unshielded Twisted Pair (C6A UTP) cable cannot be mixed
with other categories of cable because of interference from alien cross
talk. Networks using C6A UTP cable along with other categories of
cable must employ separate pathways for C6A UTP cable. Shielded
cable can be mixed with other category cable in the same pathway.
•	 No issue with deformation of the jacket
UTP cable relies on the cable jacket to reduce AXT. Bending of the
cable or deformation of the cable jacket by crushing in the cable
pathway may reduce the effectiveness of the AXT protection provided
by the jacket and create problems with transmission. Shielded cable
360˚ foil maintains shielding in all circumstances.
•	 Simplified grounding and bonding
6
“installing cable in
a live healthcare
environment can
cost up to five times
the installation cost
when the facility is
built”
Shielded cable provides a grounding and bonding mechanism within
the cable. Unshielded cable does not provide this and requires
external grounding and bonding.
Even if the C6A UTP cable passes testing during commissioning, any
subsequent MAC can disturb the cabling and introduce AXT issues. These
issues may be easy to detect but difficult to fix since the source of the
AXT failure could be anywhere along the cable path. The potential of
AXT failures coupled with the restrictions placed on accessing the cable
plant in a healthcare environment and the TIA-1179 recommendation
to enclose some cable pathways makes remediating AXT issues
problematic.
Total Cost of Ownership
When installing a cabling system, costs beyond the initial purchase,
installation, and testing costs must be considered. The cable plant is
expected to be the longest living component of the network. Initial
construction costs of a cable system are a fraction of the ongoing
operation costs and costs to complete MACs. Replacement of cable in
a live healthcare environment is the most difficult and potentially most
costly component when upgrading an operational network. The cost
of installing cable in a live healthcare environment can cost up to five
times the installation cost when the facility is built. This is due to costs
associated with working around the requirements and restrictions of an
active healthcare facility. Any savings gained from installing a lower cost
cable plant initially will be lost many times over after consideration of full
life cycle costs.
The expected lifespan of the cabling system significantly impacts the
total cost of the solution. If an organisation plans to occupy a building
longer than the expected lifespan of the cable plant, removal costs of the
existing cable must be included as part of the total cost evaluation as
well as the purchase, installation, and testing costs of the replacement
cable. Lost revenue caused by replacement of the cable system and
incremental costs of replacing the cable plant in the existing facility must
also be considered. For active facilities that operate 24/7 or are subject
to Infection Control Requirements (ICR) procedures, replacement of the
cable plant will impose addition costs of complying with ICR procedures
and/or forcing downtime of patient serving areas.
Below is an analysis of installation costs for Category 6 UTP and Category
6A shielded cable at a healthcare facility showed per port installation
7
cost.
Labour costs are based on a standard rate of $65/hour. Costs may vary
by region.
Installation Costs
Cable Type Cost Notes
C6 UTP $700 per port Includes the cost of the cable,
hardware, and installation and testing
costs.
C6A Shielded $1,050 per port Includes the cost of the cable,
hardware, and installation and testing
costs.
Estimated Lifespan
Cable Type Cost Notes
C6 UTP 5 years Assumption is requirements of
healthcare applications and upgrades
of network equipment will require an
upgrade to a 10Gb capable system in
5 years.
C6A Shielded 15 years Estimates for the lifespan of a C6A
cable plant is 15 years.
Removal Cost
Cable Type Cost Notes
C6 UTP $140 per port Estimate of cost of labour and setup
costs to meet infection control
procedures and actual removal costs.
Upgrade Cost
Cable Type Cost Notes
C6 UTP $4,000 per port Assumption is C6 UTP cable will be
replaced with C6A shielded cable.
Facility Downtime Cost
Cable Type Cost Notes
8
“Consider the effect
of the recabling
project on patient
and staff morale”
C6 UTP $? per port Costs will vary with each installation.
Potential costs include:
•	 Lost productivity of workers
disrupted by the recabling project
•	 Lost revenue from any patient
facilities that are closed during
the recabling project
While not included, consideration of the effect of the recabling project
on patient and staff morale and the potential effect on patient outcomes
represents an additional cost to the healthcare provider.
Summary of costs over the 15 year lifespan of C6A cable.
Activity Cost - C6A
shielded
Cost – C6 UTP
Initial Purchase, Installation,
and Testing
$1,050 per port $700 per port
Removal of Abandoned C6
Cable
N/A $140 per port
Purchase , Installation and
Testing of 10G cable
N/A $4,000 per port
Facility Downtime Cost N/A ?
Total $1,050 per port $4,840 per port +
Facility Downtime
© 2012 Molex
9
CONCLUSION
www.molexpn.com
This paper has discussed the advantages of a Category 6A shielded
cable solution over Category 6 cable and C6A UTP cable. Network
products, healthcare applications, and infection control procedures
support the adoption of 10GBase-T networks which require C6A cable.
TIA-1179 recommends C6A cable for any new construction in healthcare
facilities. EMI generated in healthcare environments and the adoption
of PoE devices supports the adoption of shielded cable to minimise
disruption and maximise performance on the network. The risks and
issues associated with UTP cable and the restrictions in the healthcare
environment that make remediating these issues more costly and
difficult provides a strong case for installing C6A shielded cable.
An analysis of Total Cost of Ownership shows the initial additional cost
of installing a C6A shielded system is insignificant compared to the cost
savings and efficiencies provided over the lifetime of the cable plant.
The adoption of C6A shielded cable is the best solution when installing
horizontal copper cable for your network infrastructure in healthcare
facilities.

Mais conteúdo relacionado

Mais procurados

Comparative analysis of traditional telephone and voice over-internet protocol
Comparative analysis of traditional telephone and voice over-internet protocolComparative analysis of traditional telephone and voice over-internet protocol
Comparative analysis of traditional telephone and voice over-internet protocol
Omaima_Ismail
 

Mais procurados (20)

3G&4G
3G&4G3G&4G
3G&4G
 
A 3G Femtocell Radio - Analog Devices VON Boston Networking Conference Oct 29...
A 3G Femtocell Radio - Analog Devices VON Boston Networking Conference Oct 29...A 3G Femtocell Radio - Analog Devices VON Boston Networking Conference Oct 29...
A 3G Femtocell Radio - Analog Devices VON Boston Networking Conference Oct 29...
 
Comparative analysis of traditional telephone and voice over-internet protocol
Comparative analysis of traditional telephone and voice over-internet protocolComparative analysis of traditional telephone and voice over-internet protocol
Comparative analysis of traditional telephone and voice over-internet protocol
 
ANKIT final
ANKIT finalANKIT final
ANKIT final
 
ZyXEL Success Story: Carnegie Telephone helps local hospital go wireless with...
ZyXEL Success Story: Carnegie Telephone helps local hospital go wireless with...ZyXEL Success Story: Carnegie Telephone helps local hospital go wireless with...
ZyXEL Success Story: Carnegie Telephone helps local hospital go wireless with...
 
ppt on femtocell
ppt on femtocellppt on femtocell
ppt on femtocell
 
Femtocells
FemtocellsFemtocells
Femtocells
 
Loose tube vs. tight-buffered fiber optic cable
Loose tube vs. tight-buffered fiber optic cableLoose tube vs. tight-buffered fiber optic cable
Loose tube vs. tight-buffered fiber optic cable
 
Cse gi-fi-technology-report
Cse gi-fi-technology-reportCse gi-fi-technology-report
Cse gi-fi-technology-report
 
“Design of Efficient Mobile Femtocell by Compression and Aggregation Technolo...
“Design of Efficient Mobile Femtocell by Compression and Aggregation Technolo...“Design of Efficient Mobile Femtocell by Compression and Aggregation Technolo...
“Design of Efficient Mobile Femtocell by Compression and Aggregation Technolo...
 
Femtocell
FemtocellFemtocell
Femtocell
 
Gifi
GifiGifi
Gifi
 
Small cells I : Femto cell
Small cells I :  Femto cellSmall cells I :  Femto cell
Small cells I : Femto cell
 
Report on Gi-Fi
Report on Gi-FiReport on Gi-Fi
Report on Gi-Fi
 
3g and 4g
3g and 4g3g and 4g
3g and 4g
 
Capitulo 5
Capitulo 5Capitulo 5
Capitulo 5
 
3G Technology
3G Technology 3G Technology
3G Technology
 
4 g wireless technology
4 g wireless technology4 g wireless technology
4 g wireless technology
 
4G wireless system
4G wireless system4G wireless system
4G wireless system
 
Femtocell
FemtocellFemtocell
Femtocell
 

Destaque

PSYmetaphors_presentation_2015(1)
PSYmetaphors_presentation_2015(1)PSYmetaphors_presentation_2015(1)
PSYmetaphors_presentation_2015(1)
Maxim Perevezentsev
 

Destaque (18)

OST to PST Software
OST to PST Software OST to PST Software
OST to PST Software
 
PSYmetaphors_presentation_2015(1)
PSYmetaphors_presentation_2015(1)PSYmetaphors_presentation_2015(1)
PSYmetaphors_presentation_2015(1)
 
Lectura diaria 4°b
Lectura diaria 4°bLectura diaria 4°b
Lectura diaria 4°b
 
Cyclic Redundancy Check (CRC) Error
Cyclic Redundancy Check (CRC) Error Cyclic Redundancy Check (CRC) Error
Cyclic Redundancy Check (CRC) Error
 
Week 2 Hospitality
Week 2 HospitalityWeek 2 Hospitality
Week 2 Hospitality
 
"Will you play upon this"?: Designing Auditory Displays for Early Modern Drama
"Will you play upon this"?: Designing Auditory Displays for Early Modern Drama"Will you play upon this"?: Designing Auditory Displays for Early Modern Drama
"Will you play upon this"?: Designing Auditory Displays for Early Modern Drama
 
урок 4 excel
урок 4 excelурок 4 excel
урок 4 excel
 
Balbuzie
BalbuzieBalbuzie
Balbuzie
 
inss-dir-adm-perdigao
inss-dir-adm-perdigaoinss-dir-adm-perdigao
inss-dir-adm-perdigao
 
Real estate and lease financing
Real estate and lease financingReal estate and lease financing
Real estate and lease financing
 
City and digital spaces
City and digital spacesCity and digital spaces
City and digital spaces
 
Sviluppo Psicomotorio
Sviluppo PsicomotorioSviluppo Psicomotorio
Sviluppo Psicomotorio
 
Introduction to Hospitality Industry-Definition & Orign
Introduction to Hospitality Industry-Definition & OrignIntroduction to Hospitality Industry-Definition & Orign
Introduction to Hospitality Industry-Definition & Orign
 
presentación afrikable Día de la Mujer
presentación afrikable Día de la Mujerpresentación afrikable Día de la Mujer
presentación afrikable Día de la Mujer
 
Not All Customer Experience Variation is Equal - Use Control Charts to Identi...
Not All Customer Experience Variation is Equal - Use Control Charts to Identi...Not All Customer Experience Variation is Equal - Use Control Charts to Identi...
Not All Customer Experience Variation is Equal - Use Control Charts to Identi...
 
Nc administracao-pub_teoria e questões_2015.1 - completa
 Nc administracao-pub_teoria e questões_2015.1 - completa Nc administracao-pub_teoria e questões_2015.1 - completa
Nc administracao-pub_teoria e questões_2015.1 - completa
 
ナルト
ナルトナルト
ナルト
 
Platinum Element group
Platinum Element groupPlatinum Element group
Platinum Element group
 

Semelhante a Choosing the Right Horzontal Cabling System for Healthcare - ROW

Structured Cabling Solution - White Paper
Structured Cabling Solution - White PaperStructured Cabling Solution - White Paper
Structured Cabling Solution - White Paper
Syed Firas
 
Network Cabling http://www.innovaglobal.com 877-448-4968
Network Cabling http://www.innovaglobal.com 877-448-4968Network Cabling http://www.innovaglobal.com 877-448-4968
Network Cabling http://www.innovaglobal.com 877-448-4968
Innova Global Technology
 
PCN InterMax IX1610-P Product Brochure rev 1-0 (1)
PCN InterMax IX1610-P Product Brochure rev 1-0 (1)PCN InterMax IX1610-P Product Brochure rev 1-0 (1)
PCN InterMax IX1610-P Product Brochure rev 1-0 (1)
Robert Rivenbark
 
Cat8 May 15 NCN
Cat8 May 15 NCNCat8 May 15 NCN
Cat8 May 15 NCN
Lee Stokes
 

Semelhante a Choosing the Right Horzontal Cabling System for Healthcare - ROW (20)

Structured Cabling Solution - White Paper
Structured Cabling Solution - White PaperStructured Cabling Solution - White Paper
Structured Cabling Solution - White Paper
 
Wireless Technology in Industrial Automation
Wireless Technology in Industrial AutomationWireless Technology in Industrial Automation
Wireless Technology in Industrial Automation
 
1308794-2_-_AMP_CO_Handbook_12-06[1].pdf
1308794-2_-_AMP_CO_Handbook_12-06[1].pdf1308794-2_-_AMP_CO_Handbook_12-06[1].pdf
1308794-2_-_AMP_CO_Handbook_12-06[1].pdf
 
10Gbs_Brochure_02-07[1].pdf
10Gbs_Brochure_02-07[1].pdf10Gbs_Brochure_02-07[1].pdf
10Gbs_Brochure_02-07[1].pdf
 
Copper and glass securing the foundation of your 10 gigabit data center
Copper and glass securing the foundation of your 10 gigabit data centerCopper and glass securing the foundation of your 10 gigabit data center
Copper and glass securing the foundation of your 10 gigabit data center
 
Ppt Dc 09
Ppt Dc 09Ppt Dc 09
Ppt Dc 09
 
Network Cabling http://www.innovaglobal.com 877-448-4968
Network Cabling http://www.innovaglobal.com 877-448-4968Network Cabling http://www.innovaglobal.com 877-448-4968
Network Cabling http://www.innovaglobal.com 877-448-4968
 
WIMAX Technology
WIMAX TechnologyWIMAX Technology
WIMAX Technology
 
Healthcare Infrastructure Solutions that Deliver Dramatic Savings
Healthcare Infrastructure Solutions that Deliver Dramatic SavingsHealthcare Infrastructure Solutions that Deliver Dramatic Savings
Healthcare Infrastructure Solutions that Deliver Dramatic Savings
 
PACE-IT: Introduction to Wired Network Standards
PACE-IT: Introduction to Wired Network StandardsPACE-IT: Introduction to Wired Network Standards
PACE-IT: Introduction to Wired Network Standards
 
PCN InterMax IX1610-P Product Brochure rev 1-0 (1)
PCN InterMax IX1610-P Product Brochure rev 1-0 (1)PCN InterMax IX1610-P Product Brochure rev 1-0 (1)
PCN InterMax IX1610-P Product Brochure rev 1-0 (1)
 
MELJUN CORTES networking structured_cabling
MELJUN CORTES networking structured_cablingMELJUN CORTES networking structured_cabling
MELJUN CORTES networking structured_cabling
 
Petro IndustryNews | 'Full redundant field wireless automation solutions base...
Petro IndustryNews | 'Full redundant field wireless automation solutions base...Petro IndustryNews | 'Full redundant field wireless automation solutions base...
Petro IndustryNews | 'Full redundant field wireless automation solutions base...
 
BVH Network Technology Presentation
BVH   Network Technology PresentationBVH   Network Technology Presentation
BVH Network Technology Presentation
 
A Guide to Structured Cabling - DINTEK.pdf
A Guide to Structured Cabling - DINTEK.pdfA Guide to Structured Cabling - DINTEK.pdf
A Guide to Structured Cabling - DINTEK.pdf
 
Cat8 May 15 NCN
Cat8 May 15 NCNCat8 May 15 NCN
Cat8 May 15 NCN
 
"Islands of Connectivity" are harming profitability and slowing growth
"Islands of Connectivity" are harming profitability and slowing growth"Islands of Connectivity" are harming profitability and slowing growth
"Islands of Connectivity" are harming profitability and slowing growth
 
Network Technology Presentation Bvh V01
Network Technology Presentation   Bvh V01Network Technology Presentation   Bvh V01
Network Technology Presentation Bvh V01
 
6 Tips for Superior Cable Management
6 Tips for Superior Cable Management6 Tips for Superior Cable Management
6 Tips for Superior Cable Management
 
Dual patharchwp
Dual patharchwpDual patharchwp
Dual patharchwp
 

Choosing the Right Horzontal Cabling System for Healthcare - ROW

  • 1. WHITE PAPER Molex Premise Networks CHOOSING THE RIGHT HORIZONTAL CABLING SYSTEM FOR HEALTHCARE ENVIRONMENTS Samuel Huber, Global Product Manager
  • 2. EXECUTIVE SUMMARY Installation of a cabling system in healthcare facilities involves consideration of many factors. The healthcare field provides one of the most demanding environments for a structured cabling system. Facilities are designed to operate for 50 years or longer. Healthcare facilities have many sources of electromagnetic interference (EMI) and radio frequency interference (RFI) such as medical equipment, wireless communications, and generators that can significantly impact the performance of an Unshielded Twisted Pair (UTP) structured cabling system. Infection control risk procedures and the nature of the healthcare environment place many restrictions on how and when changes to installed cabling can proceed. Recabling a healthcare facility can cost 4 to 5 times the initial installation cost due to the environment of working in a 24/7 healthcare facility. IP convergence of Voice, Paging, Security, and Building Automation Systems are adding to the diversity of systems structured cabling must support. Patient Monitoring and Interactive Patient Systems are continually increasing in sophistication. Applications running over healthcare networks such as Picture Archiving and Communication Systems, laboratory and radiological information, and Physician Order Entry systems require significant bandwidth. Adoption and implementation of Power over Ethernet (POE) devices increases the temperature of the cabling system which adversely affects performance. Adoption of 10GBase-T Ethernet is rapidly increasing and is expected to be the standard for the foreseeable future in healthcare facilities. All of these factors point toward adoption of Category 6A shielded cable as the best solution when installing horizontal copper cable for your network infrastructure in healthcare facilities.
  • 3. “Rapid adoption of 10GBase-T....over the next few years” 10GBase-T Adoption; Supports the Installation of Category 6A Cabling A research report issued by The Linley Group (www.linleygroup.com) forecasts more than 2.7 million ports of 10GBase-T to ship in 2012 compared to the 182,000 ports shipped in 2011. The Linley Group’s forecast shows a rapid increase in adoption of 10GBase-T for several different types of 10-Gbit/sec Ethernet applications over the next few years with 10GBase-T expected to become the most popular 10G application in 2014. The Dell’Oro Group reports a similar increase in adoption of 10GBase-T. The Controller and Adapter 5-Year Forecast Report states that 10-Gbit/ sec devices will grow at a compound annual growth rate of 33 percent over the next five years and exceed shipments of 1-Gbit/sec measured by ports in 2014. Adoption of Category 6A cable provides the foundation of a 10Gbase-T capable network that lower capacity Category 6 cable cannot support. 1
  • 4. 2 Healthcare Applications; Supports the Installation of Category 6A Cabling The increasing adoption and use of electronic health information is contributing to a massive increase in traffic across healthcare networks. File sizes of digital x-ray images, MRI images and CT scans can reach 30 Gigabytes. Adoption of 10 Gigabit Ethernet can decrease transmission times by 90%. A 30 Gigabyte file that takes 4 minutes to transmit at 1 Gigabit / second will take only 24 seconds at 10 Gigabits / second. Quicker transmission of medical images improves the productivity of the medical staff and contributes to improved patient outcomes. Adoption of Category 6A cable ensures the lowest transmission times across all channel lengths. The following table demonstrates the difference in transmission times for the same file across different categories of cable. Cable Cable Speed Transmission Time- 30 Gb file Category 5e 100 Megabits / second 40 minutes Category 6 1 Gigabit / second 4 minutes Category 6A 10 Gigabits / second 24 seconds IP convergence is also becoming a reality. Multiple cable systems will be consolidated on the structured cabling to support applications such as AV systems, facility controls, and patient monitoring systems. The increase in the diversity of applications on the cable plant suggests the most robust and longest lifespan cable should be installed to minimise disruption of operations. The adoption of Category 6A cable supports this dynamic. Infection Control Impacts on Structured Cabling; Supports the Installation of Category 6A Cabling Infection control is taking on increasing importance as the scope of Healthcare Associated Infections (HAI) has become known. A 2009 paper by the United States Centre for Disease Control and Prevention (CDC) estimated the total cost for HAI in the year 2007 to be between 28 and 33 billion dollars. About 10% of patients acquire an infection after admission, according to the CDC, resulting in over 1.7 million HAIs. Approximately one-third of all hospital infection threats are airborne. To reduce the potential of airborne HAIs, Infection-control measures in a hospital environment include stringent regulations to contain airborne particles when removing ceiling tiles or other access to the plenum space is required. When performing moves, adds, or changes (MACs) to cable “A 30 Gigabyte file that takes 4 minutes to transmit at 1 Gigabit / second will take only 24 seconds at 10 Gigabits / second”
  • 5. 3 “Shielded cabling will minimise or eliminate the negative effects of EMI on the network” located in a plenum, the access areas to the plenum must be enclosed in a tent or the entire area around the access space may require isolation from the rest of the floor to prevent the spread of airborne contaminants. In administrative and non-patient service areas where healthcare operations are not 24/7, work can be done after hours to reduce the impact on facility operations. In areas where operations occur 24/7, patient care and activities may be impacted and downtime for rooms and equipment connected to the cable plant may need to be scheduled. In either case, complying with infection control procedures will add time and cost to MACs for structured cabling. Installing the highest-performing cabling up front allows for the longest possible life cycle of the cable plant and minimises the effect on patient care. Adoption of Category 6A cable supports the longest cable lifespan. EMI in the Healthcare Environment; Supports the Installation of Category 6A Shielded Cabling The adoption and use of technology in healthcare creates an environment full of electromagnetic interference (EMI). EMI is generated from diagnostic and radiology equipment, wireless networks, and many other sources. This results in performance degradation on the network. Some of these devices in turn may be affected by EMI generated from the structured cabling. The TIA-1179 Healthcare Cabling standard recognizes the potential effects of EMI and suggests additional measures including isolation from or routing of cables around equipment capable of generating EMI. In addition TIA-1179 suggests testing cable performance while equipment is operating. Shielded cabling will minimise or eliminate the negative effects of EMI on the network as well as protect equipment from EMI generated by the network. Shielded cable includes a foil sheath around each wire pair that shields the cable from external EMI from other cables as well as other devices such as medical equipment that generates EMI. The benefits and advantages of using shielded cabling increases as the use of EMI generating equipment increases. Power over Ethernet; Supports the Installation of Category 6A Shielded Cabling The IEEE 802.3at-2009 PoE standard, commonly known as PoE Plus, provides up to 25.5 W of power to a PoE device over a 4 pair cable. PoE Plus provides the capability for many more devices such as LCD displays, door access controls, pan-tilt-zoom cameras, and biometric sensors to receive power over the network. PoE allows for convergence of many systems that previously required separate cable systems to the structured cable system used by the network.
  • 6. 4 “The TIA standard addresses insertion loss by de-rating the cable as the temperature of the cable increases.” Delivering power via the cable causes a temperature rise within the cabling, which can result in increased insertion loss and potentially reduce network performance. The TIA standard addresses insertion loss by de-rating the cable as the temperature of the cable increases. As can be seen in the following graph, C6A shielded cable is de-rated less than unshielded cable. This allows shielded cable to support longer channels as temperatures and/or provide additional headroom on the channel. TIA De-rating for Different Temperatures Maximum Horizontal Cable Length (m) Temperature (˚C) The superior performance of Category C6A shielded cable over unshielded cable at higher temperatures makes supporting POE and IP convergence easier. TIA-1179 Recommendations; Supports the Installation of Category 6A Cabling The TIA-1179 Healthcare Facility Telecommunications Infrastructure Standard accounts for the special needs and requirements presented in a healthcare environment. The topics discussed in this paper factored into the recommendations contained in TIA-1179. Following are a summary of recommendations that impact the choice of cabling. • Category 6A cable is recommended for new construction to allow for the longest possible life cycle. This is consistent with the TIA 942 and IEC 24764 Data Centre standards. 65 70 75 80 85 90 95 20 25 30 35 40 45 50 55 60 Cat 6A UTP Cat 6A F/UTPShielded
  • 7. 5 “Shielded cable eliminates the need to test for AXT” • Enclosed pathways for cable should be considered in air-handling spaces to meet infection control requirements. • Design cabling systems to support the longest possible lifespan to support the bandwidth requirements and mission critical nature of data transmission within healthcare facilities. Advantages of Shielded Shielded vs. Unshielded UTP Cable Previous sections have discussed the advantage shielded cable has over UTP cable with respect to superior EMI performance, superior performance in high temperature environments, and elimination of signal radiation from the cable. In addition, shielded cable offers additional advantages. • Reduced Outer Diameter for shielded cable compared to unshielded cable The smaller diameter of shielded cable allows for more cables in each pathway or a reduction in the size of the pathway for the same number of cables. • Elimination of Alien Cross Talk (AXT) testing Shielded cable eliminates the need to test for AXT. This reduces the cost and time required for testing of the cable plant. UTP cabling requires extensive testing for AXT. • Ability to mix different categories of cable in the same pathway Category 6A Unshielded Twisted Pair (C6A UTP) cable cannot be mixed with other categories of cable because of interference from alien cross talk. Networks using C6A UTP cable along with other categories of cable must employ separate pathways for C6A UTP cable. Shielded cable can be mixed with other category cable in the same pathway. • No issue with deformation of the jacket UTP cable relies on the cable jacket to reduce AXT. Bending of the cable or deformation of the cable jacket by crushing in the cable pathway may reduce the effectiveness of the AXT protection provided by the jacket and create problems with transmission. Shielded cable 360˚ foil maintains shielding in all circumstances. • Simplified grounding and bonding
  • 8. 6 “installing cable in a live healthcare environment can cost up to five times the installation cost when the facility is built” Shielded cable provides a grounding and bonding mechanism within the cable. Unshielded cable does not provide this and requires external grounding and bonding. Even if the C6A UTP cable passes testing during commissioning, any subsequent MAC can disturb the cabling and introduce AXT issues. These issues may be easy to detect but difficult to fix since the source of the AXT failure could be anywhere along the cable path. The potential of AXT failures coupled with the restrictions placed on accessing the cable plant in a healthcare environment and the TIA-1179 recommendation to enclose some cable pathways makes remediating AXT issues problematic. Total Cost of Ownership When installing a cabling system, costs beyond the initial purchase, installation, and testing costs must be considered. The cable plant is expected to be the longest living component of the network. Initial construction costs of a cable system are a fraction of the ongoing operation costs and costs to complete MACs. Replacement of cable in a live healthcare environment is the most difficult and potentially most costly component when upgrading an operational network. The cost of installing cable in a live healthcare environment can cost up to five times the installation cost when the facility is built. This is due to costs associated with working around the requirements and restrictions of an active healthcare facility. Any savings gained from installing a lower cost cable plant initially will be lost many times over after consideration of full life cycle costs. The expected lifespan of the cabling system significantly impacts the total cost of the solution. If an organisation plans to occupy a building longer than the expected lifespan of the cable plant, removal costs of the existing cable must be included as part of the total cost evaluation as well as the purchase, installation, and testing costs of the replacement cable. Lost revenue caused by replacement of the cable system and incremental costs of replacing the cable plant in the existing facility must also be considered. For active facilities that operate 24/7 or are subject to Infection Control Requirements (ICR) procedures, replacement of the cable plant will impose addition costs of complying with ICR procedures and/or forcing downtime of patient serving areas. Below is an analysis of installation costs for Category 6 UTP and Category 6A shielded cable at a healthcare facility showed per port installation
  • 9. 7 cost. Labour costs are based on a standard rate of $65/hour. Costs may vary by region. Installation Costs Cable Type Cost Notes C6 UTP $700 per port Includes the cost of the cable, hardware, and installation and testing costs. C6A Shielded $1,050 per port Includes the cost of the cable, hardware, and installation and testing costs. Estimated Lifespan Cable Type Cost Notes C6 UTP 5 years Assumption is requirements of healthcare applications and upgrades of network equipment will require an upgrade to a 10Gb capable system in 5 years. C6A Shielded 15 years Estimates for the lifespan of a C6A cable plant is 15 years. Removal Cost Cable Type Cost Notes C6 UTP $140 per port Estimate of cost of labour and setup costs to meet infection control procedures and actual removal costs. Upgrade Cost Cable Type Cost Notes C6 UTP $4,000 per port Assumption is C6 UTP cable will be replaced with C6A shielded cable. Facility Downtime Cost Cable Type Cost Notes
  • 10. 8 “Consider the effect of the recabling project on patient and staff morale” C6 UTP $? per port Costs will vary with each installation. Potential costs include: • Lost productivity of workers disrupted by the recabling project • Lost revenue from any patient facilities that are closed during the recabling project While not included, consideration of the effect of the recabling project on patient and staff morale and the potential effect on patient outcomes represents an additional cost to the healthcare provider. Summary of costs over the 15 year lifespan of C6A cable. Activity Cost - C6A shielded Cost – C6 UTP Initial Purchase, Installation, and Testing $1,050 per port $700 per port Removal of Abandoned C6 Cable N/A $140 per port Purchase , Installation and Testing of 10G cable N/A $4,000 per port Facility Downtime Cost N/A ? Total $1,050 per port $4,840 per port + Facility Downtime
  • 11. © 2012 Molex 9 CONCLUSION www.molexpn.com This paper has discussed the advantages of a Category 6A shielded cable solution over Category 6 cable and C6A UTP cable. Network products, healthcare applications, and infection control procedures support the adoption of 10GBase-T networks which require C6A cable. TIA-1179 recommends C6A cable for any new construction in healthcare facilities. EMI generated in healthcare environments and the adoption of PoE devices supports the adoption of shielded cable to minimise disruption and maximise performance on the network. The risks and issues associated with UTP cable and the restrictions in the healthcare environment that make remediating these issues more costly and difficult provides a strong case for installing C6A shielded cable. An analysis of Total Cost of Ownership shows the initial additional cost of installing a C6A shielded system is insignificant compared to the cost savings and efficiencies provided over the lifetime of the cable plant. The adoption of C6A shielded cable is the best solution when installing horizontal copper cable for your network infrastructure in healthcare facilities.