Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com 
ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 
www.ijera.com 141 | P a g e 
Performance Analysis of a Shell Tube Condenser for a Model Organic Rankine Cycle for Use in Geothermal Power Plant Haile Araya Nigusse1, Hiram M. Ndiritu1, Robert Kiplimo1 1Department of Mechanical Engineering, Jomo Kenyatta University of Agriculture and Technology, Kenya ABSTRACT The global energy demand increases with the economic growth and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining. In addition to this harmful combustion byproducts are resulting global warming. However, the increase of environmental concerns and energy crisis can be minimized by sustainable utilization of the low to medium temperature heat resources. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. Heat exchangers are the main components of the Organic Rankine Cycle power plant which receives heat energy from the heat source to evaporate and condense the low boiling temperature organic working fluid which in turn drives the turbine to generate power. This paper presents a simplified approach to the design, fabrication and performance assessment of a shell tube heat exchanger designed for condenser in a model Organic Rankine Cycle geothermal power plant. The design involved sizing of heat exchanger (condenser) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated geothermal brine. The results of the experiment indicated that the heat exchanger is thermally suitable for the condenser of the model power plant. 
Keywords - Shell tube heat Exchanger, Heat transfer Co-efficient, LMTD. 
I. Introduction 
Energy consumption increases with growth in economies and population. The increase in energy demand will occur mainly in developing countries, where economic growth rates are high and people are shifting from biomass energy sources like wood and agricultural waste to electricity. However, the increase of environmental concerns and energy crisis has resulted in need for a sustainable approach to the utilization of the earth's energy resources. Worldwide, geothermal power plants have a capacity of about 12 GW power generations as of 2013 and in practice supply only about 0.3% of global power demand [1]. However, the conventional geothermal power plants utilize the high temperature and pressure geo-fluid and operate at low efficiency due to the heat loss in the exhausted steam and brine. The Organic Rankine Cycle power plant is a very attractive option for utilization of low-grade geothermal heat sources for power generation. Heat exchangers are the main components of the Organic Rankine Cycle geothermal power plant to receives heat energy from the hot water (brine) and vaporize and condense the low boiling temperature organic working fluid which drives the turbine to generate power. 
This paper presents design, fabrication and performance assessment test of the shell and tube heat exchanger designed for the condenser of a model Organic Rankine Cycle power plant. Performance tests of the heat exchanger were conducted by relating the inlet and outlet temperatures and the overall heat transfer coefficient to the rate of heat transfer between the working fluid (n-pentane) and the cooling water. Heat exchanger is an apparatus or equipment built for efficient heat transfer between two or more fluid streams at different temperatures. The shell tube heat exchanger is widely used in many binary cycle power plants. This widespread application can be justified by the availability of codes and standards for design and fabrication; it can be manufactured from a wide variety of materials and ability to be produced in the widest variety of sizes and styles. Moreover, It can be designed for a wide range of limits on the operating temperature and pressure [2, 3]. A typical counter flow shell and tube heat exchanger is shown in figure 1 
RESEARCH ARTICLE OPEN ACCESS
Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com 
ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 
www.ijera.com 142 | P a g e 
Figure 1: Counter flow shell and tube heat exchanger 
[1] 
The three most commonly used types of shell and 
tube heat exchanger designs are fixed tube sheet, U-tube, 
and the floating head type. In all types, the front 
end head is stationary, while the rear-end head could 
be either stationary or floating depending upon the 
thermal stresses in the shell, tube, or tube sheet due to 
temperature differences as a result of heat transfer. 
The heat exchangers are built in accordance with 
three mechanical standards that specify design, 
fabrication, and materials of unfired shell and tube 
heat exchangers. The two most common heat 
exchanger design problems are those of sizing and 
rating of the heat exchanger [4]. 
Different types of heat exchangers have been 
developed to meet the widely varying application 
based on, operating principles, flow arrangement, 
compactness, number of fluids and constructional 
design features. Among the heat exchangers are plate, 
shell tube and shell coil heat exchangers. Shell and 
tube heat exchangers are basically non compact 
exchangers. Generally the Heat transfer surface area 
per unit volume is high ranging from about 50m2/m3 
to 100m2/m3. Thus, they require a considerable 
amount of space, supporting structure, and higher 
capital and installation costs. The shell and tube heat 
exchangers are more effective for applications in 
which compactness is not a priority [4]. 
Madhawa [5] investigated the at plate and shell tube 
heat exchangers and found that at plate type heat 
exchangers are effective in the evaporator and 
condenser when considering low-temperature heat 
sources in which large heat exchanger area (per unit 
power output) is required. The plate type heat 
exchangers are preferred due to their compactness 
and high heat transfer co-efficient which result to less 
heat transfer area than would be needed using shell 
and tube heat exchanger. However, at plate 
exchanger involves high manufacturing cost and 
maintenance cost. Hence it affects the overall cost of 
the power plant. 
Bambang [6] also compared the at plate and shell 
tube heat exchangers and found that the shell tube 
type is advantageous due to simplicity in geometry, 
well established design procedure, can be constructed 
from a wide range of materials, uses well-established 
fabrication techniques and is easily cleaned. 
Moreover the shell tube heat exchanger can be 
designed and manufactured locally from a wide range 
of materials. However the heat transfer optimization 
and minimizing the pressure drop within the shell and 
tube exchanger need to be addressed. 
The design of heat exchangers involves establishing 
the right flow configuration of interacting fluids. 
Parallel and counter flows are the two common flow 
configuration of a shell tube heat exchanger. The 
counter flow configuration is the predominantly 
preferred flow direction in liquid to liquid heat 
exchangers since it results in a higher temperature 
difference driving the heat transfer within the heat 
exchanger, smaller heat transfer surface area required 
[7]. Moreover counter flow configuration is most 
effective design when there is a temperature cross. A 
temperature cross occurs when the desired outlet 
temperature of one fluid is between the inlet and 
outlet temperatures of the other fluid [8]. 
Furthermore, various studies have been carried out on 
optimization of the performance of shell and tube 
heat exchangers using the performance parameters 
approach. The heat transfer coefficient values are 
evaluated using the log mean temperature difference 
(LMTD) method from the temperature difference and 
the heat transfer area for known inlet and outlet 
temperature heat exchangers [9]. Thundil et al. [10] 
investigated the effect of inclination of baffles in the 
shell by simulating a model shell and tube heat 
exchanger. He compared the impact of baffle 
inclination on fluid flow, pressure drop and the heat 
transfer characteristics of a shell tube heat exchanger 
using three different inclination angles (0o, 10o and 
20o). They concluded that shell and tube heat 
exchanger with 20o baffle inclination angle results in 
better performance compared to 10o and 0o 
inclination angles. 
A. Singh et al. [11] also conducted an experimental 
analysis on the performance of a shell tube heat 
exchanger with segmented baffles at three different 
orientations (0o, 30o and 60o). They analyzed the 
system for laminar flow with varying Reynold 
number and concluded that the heat transfer 
coefficient increases with increase in Reynold 
number in shell tube heat exchanger for both hot fluid 
and cold fluids. They observed that, with the 
introduction of the baffles, the heat transfer 
coefficient increases leading to more heat transfer 
rate due to introduction of swirl and more convective 
surface area.
Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com 
ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 
www.ijera.com 143 | P a g e 
In general, conventional shell tube heat exchangers 
result in high shell side pressure drop and formation 
of recirculation zones near the baffles. To overcome 
the challenge helical baffles, which gives better 
performance than single segmental baffles, can be 
used. But these baffles involve high manufacturing 
and maintenance cost. Hence the effectiveness and 
cost must be considered in the heat exchanger design 
[10]. 
II. Methodology 
2.1 Heat exchanger selection 
Heat is transferred from one fluid to other in the heat 
exchanger. The process was studied by taking into 
account the energy balance. Studies in the application 
of heat exchangers leads to the selection of three 
important attributes related to the performance of 
ORC. Which are heat transfer area, overall heat 
transfer coefficient and temperature difference [13]. 
Different type of heat exchanger (plates, tubular, 
shell and tube etc) can be used for the condenser of 
an Organic Rankine Cycle geothermal power plant. 
For indirect heat transfer between two fluids, the 
shell tube heat exchangers are more effective. In this 
study, due to the advantages of fairly simple 
geometry, well established design procedure, can be 
fabricated from a wide range of materials, uses well 
established fabrication techniques and ease of 
cleaning, a shell tube type heat exchanger was 
selected for the condenser of the model power plant. 
The design of heat exchanger involves establishing 
the right flow configuration of interacting fluids. 
Parallel flow and counter flows are the two most 
commonly used flow configuration of shell tube heat 
exchanger. The counter-flow configuration is the 
predominantly preferred flow direction in liquid to 
liquid heat exchangers since it results in a higher 
temperature difference driving the heat transfer 
within the heat exchanger, smaller heat transfer 
surface area required. Moreover counter flow 
configuration is most effective design when there is a 
temperature cross. A temperature cross occurs when 
the desired outlet temperature of one fluid is between 
the inlet and outlet temperatures of the other fluid. 
Figure 2: The design of copper tube configuration 
and baffle spacing 
The design of the condenser is a fixed tube counter 
flow shell and tube heat exchanger as shown in figure 
1. Moreover, the fluids flow pattern in the exchanger 
is in such way that the cooling water flows in the tube 
side and the secondary fluid (n-pentane) condenses in 
the shell side of the heat exchanger. This type of fluid 
pattern allows fouling fluid to flow through the tubes 
(easier to clean) and the organic working fluid (n-pentane) 
to flow through the shell side where a 
turbulent flow is obtained on the shell side due the 
baffles. 
2.2 Design and construction of the heat exchanger 
In design of short heat exchangers it is reasonable to 
assume a constant value of overall heat transfer 
coefficient (U). The log-mean temperature difference 
(LMTD) method is useful for the sizing and rating of 
heat exchanger of known mass flow rate and range of 
temperature difference between the inlet and outlet of 
fluid streams. The following equations have been 
used in relating the heat transfer surface area through 
which heat flow occurs under the driving force of 
temperature difference, amount of heat transferred 
and overall heat transfer coefficient. 
Figure 3: Schematic diagram of flow configuration 
of counter flow shell and tube heat exchanger
Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com 
ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 
www.ijera.com 144 | P a g e 
(1) 
Where heat capacity rate for hot or cold fluid, C = 
mCp, and Cp is specific heat capacity at constant 
pressure. 
During the heat transfer process energy is conserved 
therefore for the cold and hot fluid; 
(2) 
Where heat capacity rate for hot or cold fluid C = 
mcp, subscripts hi and ho represent inlet and outlet of 
hot fluid respectively and Ci and Co represent cold 
fluid inlet and outlet respectively. 
Heat transferred in the process (Q) may be related to 
the overall heat transfer coefficient U and the mean 
temperature difference ΔTlmtd by: 
(3) 
Where A is heat transfer surface area and ΔTlmtd is 
the log mean temperature difference. The log mean 
temperature difference of the heat exchanger can be 
determined as follows: 
(4) 
Where, ΔT1 and ΔT2 represent the temperature 
differences at the inlet and exit of the heat exchanger 
respectively as shown in figure 3. 
The heat exchanger was designed using the design 
equations 1-4. The details of the designed shell tube 
heat exchanger are shown in Table 1. Figure 2 shows 
the assembly of the copper tubes to the tube sheet and 
the baffles placed on the respective position. 
Table 1: Design details of the condenser 
Description Tube side Shell side 
Fluid pattern pentane 
cooling 
water 
Number of tubes 21 
Total tube length 8.4 
Tube diameter 
(DO/DI)(mm) 
12.7/10.9 
150 
Heat transfer area (m2) 0.2634 
Number of pass 1 
Tube configuration 
300 
triangular 
Tube pitch 16 
Material Copper 
Galvanized 
steel 
The shell of the heat exchanger was constructed by 
rolling a plate of galvanized steel. The plate was cut 
to a rectangular shape of size 471mm by 750mm and 
four holes were drilled for the inlet and outlet of the 
two fluids before the plate was rolled. The plate was 
then rolled and brazed using gas welding and 
produced a cylinder of 150mm in diameter and height 
of 750mm. The tube sheets were made from a round 
at piece of galvanized steel with holes drilled for the 
tube ends in a precise location and pattern relative to 
one another. 
Figure 4: The shell and tube heat exchanger tube 
bundle 
Two baffles were also provided as shown with a 
baffle pitch of 150mm. The optimum baffle pitch 
(spacing between segmental baffles) and the baffle 
cut were applied to determine the cross flow velocity 
and hence the rate of heat transfer and minimize 
pressure drop. A baffle spacing of 0.2 to 1 times the 
inside shell diameter is commonly used. A baffle cut 
of 20 to 25% provides a good heat-transfer with the 
reasonable pressure drop [14]. A 20% baffle cut was 
applied for this particular shell tube heat exchanger. 
The % cut for segmental baffle refers to the cut away 
height from its diameter. 
Copper tubes were cut at a length of 400mm and each 
tube was brazed using a gas welding to the hole 
provided on the tube sheet to produce a tube bundle 
as shown in figure 4. The tube bundle was then 
inserted to the main shell and the two tube sheets 
were brazed to provide air tight joints. 
2.3 Heat exchanger leakage test 
It is important to test the leak tightness of the heat 
exchanger at the operating temperature and pressure 
before carrying out a performance test. Leak 
tightness test was carried out to ensure that the heat 
exchanger performs adequately at the design 
temperatures and pressures. The heat exchanger was 
tested for its leak tightness at room temperature and 
the design pressure of 2.5 bar using water circulating
Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com 
ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 
www.ijera.com 145 | P a g e 
in the tube side. After inspecting for the leak, water was circulated on the shell side of the exchanger with the help of a water pump. During the tests, leaks were mainly detected on the welded joints between the shell and the tube sheet, copper tubes and tube sheet joints and on the joints of the inlet and exit pipes of the heat exchanger. A sealing material called STAG was applied on the leaking edges and test was carried again until no further leakage was detected. STAG is easy break, smooth consistency and lead-free jointing compound. It is commonly used for sealing of high pressure and temperature pipes. It is a non-poisonous and resists to organic chemicals. 
2.4 Performance test of the heat exchanger 
The performance test unit consists of an overhead cooling water tank, the heat exchanger, secondary fluid tank and feed pump. A schematic sketch showing valves, pressure gauges, flow meters, and the location of temperature sensors is given in Figure 5. The cooling water flow rate was controlled by opening valve HV1. The feed pump supplies the organic working fluid (n-pentane) at constant flow rate of 0.12kg/s to the exchanger (evaporator) through the flow meter and condenses on the shell side in a counter-current to the cooling water flow. The condensed working fluid from the exchanger was then directed back to the secondary fluid tank. Figure 5: Schematic sketch of the heat exchanger performance test experiment. 
The length of one test section was set to be two minutes. A set of four thermocouples were provided to record pertinent temperatures at the inlet and exit of each fluid as shown in the figure 5. The thermocouples were connected to a data logger of type TDS-530. The data logger was set to print each temperature in the test section of two minutes. A set of five measurements were conducted by varying the cooling water mass flow rate and maintaining the secondary fluid (n-pentane) flow rate constant. The temperature indicators on the data logger displayed the following temperatures. 
 T1 Cooling water inlet temperature to condenser 
 T2 Cooling water exit temperature from condenser 
 T3 Secondary fluid temperature inlet to condenser 
 T4 Secondary fluid temperature exit from condenser 
2.5 Experimental procedure 
The overhead cooling water tank was filled with water. The valve HV1 was opened and cooling water was allowed into the shell side of the heat exchanger (condenser). The feed pump was switched on and the secondary fluid (n-pentane) allowed to flow into the tube side of the heat exchanger. It was waited until the steady state has been reached. At steady state, all the four temperatures and flow rates of cooling water and secondary fluid were noted down. The flow rate of cooling water was changed and waited for new steady state to be reached. 
2.6 Thermal parameters evaluation 
The following relations were applied to evaluate the remaining performance parameters of the heat exchanger. The LMTD method was used since the inlet and outlet temperatures of both the cooling water and the secondary fluid are known. (5) (6) Where subscripts c and h represent cold and hot fluid respectively, i and o represent for inlet and outlet respectively. Heat capacity rate for hot or cold fluid C = mCp, A is the heat transfer area and U is overall heat transfer coefficient and TLMTD is the log mean temperature difference. 
1. Pressure drop of pentane, ıPp = Pi - Po 
2. Cooling water temperature difference, ıTw = Twi - Two 
3. Pentane Temperature difference, ıTp = Tpi - Tpo 
4. Log mean temperature difference TLMTD for counter flow heat exchanger: 
Where: Twi is cooling water inlet temperature; Two is Cooling water outlet temperature, Tpi is pentane inlet temperature, and Tpo is pentane outlet temperature.
Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com 
ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 
www.ijera.com 146 | P a g e 
III. Results and discussions 
Performance test of the heat exchanger (condenser) was carried out. Three parameters were studied to investigate the performance of the heat exchanger. The heat transferred, overall heat transfer coefficient and pressure drop within the shell and tube heat exchanger having secondary fluid (n-pentane) in tube side and cooling water in the shell side in counter flow configuration. Five experiments were conducted at different cooling water mass flow rates. Figure 6: Variation of overall heat transfer coefficient with increase in cooling water mass flow rate In the process, increase in the flow rate of cooling water resulted in increase in the overall heat transfer coefficient as can be seen from curve in figure 6. The curve shows that an increase of cooling water flow rate from 0.15kg/s to 0.35kg/s increased the overall heat transfer coefficient of the heat exchanger by 1.21%. This is because increase in the mass flow rate of cooing water increases the heat energy transferred. Since the specific heat remains almost constant, cooling water outlet temperature should increase to comply with law of conservation of energy and hence as the flow rate of the cooling water is increased, the tube side overall heat transfer coefficient also increases. 
Figure 7: Variation of heat duty with increase in cooling water mass flow rate Similarly, the variation of heat transferred (heat duty) with mass flow rate of the cooling water is shown in Figure 7. The curve shows that heat transferred increased by 4.26% with an increase of cooling water flow rate from 0.15kg/s to 0.35kg/s. This is because increase in the cooling water mass flow rate increases over all heat transfer coefficient in a lower rate than the heat energy transferred. Figure 8: Variation of pressure drop with increase in cooling water mass flow rate 
The curve in figure 8 shows the variation of pressure drop values with increase in cooling water mass flow rate. It was observed that the pressure drop increased from 1.5kPa to 3.5kPa in the tube side and in the shell side pressure drop increased from 1.3kPa to 2.4kPa with increase in cooling water flow rate in heat exchanger. Shell and tube heat exchangers generally experience pressure drop mainly due to friction, change in thermodynamic properties like viscosity and density through the heat exchanger as a result of heating or cooling, acceleration and deceleration of fluid with change is flow cross section etc. This pressure drop may increase pumping power and may affect the service time of structural
Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com 
ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 
www.ijera.com 147 | P a g e 
components of the heat exchanger. However compared to rate of change of the heat transferred the rate of increase in pressure drop is reasonable. 
IV. Conclusion 
Shell and tube heat exchanger was designed; fabricated and experimental test was conducted to examine the performance of the heat exchanger (condenser). The performance parameters, the overall heat transfer coefficient, heat transferred and pressure drop at different cooling water mass flow rates were evaluated. The main points are summarized as follows. 
 The pressure drop gradually increased with increase in cooling water flow rate in heat exchanger. This may increase pumping power which in turn decreases the efficiency of the model power plant. However, the rate of increase in pressure drop is very small compared to rate of increase in heat transfer. Hence the rate of increase in pump work is reasonably minimal. 
 The results of the performance test indicated that the overall heat transfer coefficient is greater than the assumed overall heat transfer coefficient of heat exchanger in the design. This implies that the heat exchanger is thermally suitable for the evaporator of the model power plant. 
 The results of the performance test revealed that the heat exchanger is working satisfactorily under standard conditions. The test results were compared with the design data and the performance parameters reasonably close to the design performance data. Thus the heat exchanger is reliable and can be applied for the evaporator of the model Organic Rankine Cycle power plant. 
References 
[1] A. Hadidi, “A new design approach for shell and tube heat exchangers using competitive algorithm (ICA) from economic point of view,” Energy Conversion and Management, vol. 67, pp. 66 - 74, 2013 
[2] S. Vangapally, “Design, Fabrication and Testing of FRP shell Counter-flow heat Exchanger,” International Journal of Engineering Science and Innovative Technology (IJESIT), vol. 3. 2014. 
[3] R. K. Shah, “Heat Exchangers” University of Kentueky 
[4] H.D. Madhawa Hettiarachchi, “Optimum design criteria for an Organic Rankine cycle using low-temperature geothermal heat sources,” Energy, vol. 32, pp 1698- 1706,2007 
[5] Bambang P., “Model of Binary Cycle Power Plant using Brine as thermal Energy Source 
and Development Potential in Sibayaka,” International Journal of Electrical and Computer Science IJECS-IJENS, vol. 11, pp. 02. 
[6] T. Kuppan, Heat Exchanger Design Handbook. Marcel Dekker,200 
[7] Akash Pandey, “Performance Analysis of a Compact Heat Exchanger,” Master’s thesis, National Institute of technology Rourkela, 2011. 
[8] F.P Incropera and D. P.Dewitt, Introduction to Heat Transfer. New York, USA, 2006. 
[9] B. Gay “Shell-side heat transfer in baffled cylinderical Shell and tube exchangers an electrochemical mass- trasfer modelling technique, ” international Journal of Heat and Mass transfer, vol. 19, pp. 995-1002, 1976 
[10] M. A. Mehrabian, “The overall hat transfer characterstics of doublé pepe hat exchanger: Comparison of experimental data with preditions of standard correlations,” International Journal of Engineering, vol. 15, pp. 395-406, 2012 
[11] R. Thundil, “Shell side numerical analysis of a Shell and tube heat exchanger considering the effect of bafle inclination angle on fluid flow,” International Journal of Thermal Science. vol. 16, no.4, pp. 1165- 1174 
[12] Amarjit Singh and Satbir S. Sehgal, “Thermohydraulic Analysis of Shell and tube Heat Exchanger with Segmental Baffles,” Hindawi Publishing corporation, vol.(Article ID) 548676, pp. 5 pages, 2013 
[13] Umesh K ,”Optimization and selection of Organic Rankine cycle for low grade heat recovery by using graph theoretical approach,” Department of Mechanical Engineering, Faculty of Engineering and Technology, Jamia Millia Isllia, New Delhi, India. 
[14] Patel, “Shell and Tube Heat Exchanger Thermal Design with optimization of mass flow rate and baffle spacing,” International Journal of Advanced Engineering Research and Studies, E- ISSN2249-8974

Mais conteúdo relacionado

Mais procurados

A Study on Various Heat Transfer Enhancement Techniques
A Study on Various Heat Transfer Enhancement TechniquesA Study on Various Heat Transfer Enhancement Techniques
A Study on Various Heat Transfer Enhancement TechniquesIRJET Journal
 
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...IRJET Journal
 
IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...
IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...
IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...IRJET Journal
 
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...IRJET Journal
 
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...IRJET Journal
 
Numerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnelsNumerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnelseSAT Journals
 
Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...
Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...
Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...IJAEMSJORNAL
 
IRJET- A Review of Solar Water Heater Performance Factors
IRJET- A Review of Solar Water Heater Performance FactorsIRJET- A Review of Solar Water Heater Performance Factors
IRJET- A Review of Solar Water Heater Performance FactorsIRJET Journal
 
Exergy analysis of inlet water temperature of condenser
Exergy analysis of inlet water temperature of condenserExergy analysis of inlet water temperature of condenser
Exergy analysis of inlet water temperature of condenserIJERA Editor
 
COPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC Summary
COPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC SummaryCOPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC Summary
COPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC SummaryYoussef Tlem
 
ayush balagopal final ppt
ayush balagopal final pptayush balagopal final ppt
ayush balagopal final pptAYUSH BALAGOPAL
 
Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...
Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...
Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...Ijrdt Journal
 
Analysis of various designing parameters for earth air tunnel heat exchanger ...
Analysis of various designing parameters for earth air tunnel heat exchanger ...Analysis of various designing parameters for earth air tunnel heat exchanger ...
Analysis of various designing parameters for earth air tunnel heat exchanger ...Sudhakar kumar
 
Natural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinderNatural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinderIAEME Publication
 
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...IAEME Publication
 

Mais procurados (18)

A Study on Various Heat Transfer Enhancement Techniques
A Study on Various Heat Transfer Enhancement TechniquesA Study on Various Heat Transfer Enhancement Techniques
A Study on Various Heat Transfer Enhancement Techniques
 
30120140507001
3012014050700130120140507001
30120140507001
 
C502021133
C502021133C502021133
C502021133
 
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
IRJET-Numerical Investigation on Performance of VCR System using Shell and Tu...
 
IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...
IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...
IRJET- A Review on Thermal Analysis and Optimization of Heat Exchanger Design...
 
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
 
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
 
Numerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnelsNumerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnels
 
Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...
Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...
Parametric and Quantitative Analysis on the Development of Shell and Tube Hea...
 
IRJET- A Review of Solar Water Heater Performance Factors
IRJET- A Review of Solar Water Heater Performance FactorsIRJET- A Review of Solar Water Heater Performance Factors
IRJET- A Review of Solar Water Heater Performance Factors
 
Exergy analysis of inlet water temperature of condenser
Exergy analysis of inlet water temperature of condenserExergy analysis of inlet water temperature of condenser
Exergy analysis of inlet water temperature of condenser
 
COPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC Summary
COPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC SummaryCOPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC Summary
COPRODUCTION OF GEOTHERMAL POWER FROM OIL AND GAS FIELDS - EXC Summary
 
Gd3411261132
Gd3411261132Gd3411261132
Gd3411261132
 
ayush balagopal final ppt
ayush balagopal final pptayush balagopal final ppt
ayush balagopal final ppt
 
Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...
Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...
Enhancement of heat transfer in tube in-tube heat exchangers using twisted in...
 
Analysis of various designing parameters for earth air tunnel heat exchanger ...
Analysis of various designing parameters for earth air tunnel heat exchanger ...Analysis of various designing parameters for earth air tunnel heat exchanger ...
Analysis of various designing parameters for earth air tunnel heat exchanger ...
 
Natural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinderNatural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinder
 
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
 

Destaque

6563.nuclear models
6563.nuclear models6563.nuclear models
6563.nuclear modelsakshay garg
 
Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...
Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...
Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...theijes
 
Master's Thesis Report
Master's Thesis ReportMaster's Thesis Report
Master's Thesis ReportMohamed Shahin
 
Make power out of your waste heat - Organic Rankine Cycle
Make power out of your waste heat - Organic Rankine Cycle Make power out of your waste heat - Organic Rankine Cycle
Make power out of your waste heat - Organic Rankine Cycle Sindhu Maiyya
 
Word Problem Solver for Probability
Word Problem Solver for ProbabilityWord Problem Solver for Probability
Word Problem Solver for ProbabilityIJERA Editor
 
Liquid crystal bio-based epoxy coating with enhanced performance
Liquid crystal bio-based epoxy coating with enhanced performanceLiquid crystal bio-based epoxy coating with enhanced performance
Liquid crystal bio-based epoxy coating with enhanced performanceIJERA Editor
 
Single Mode Optical Fiber in Rof System Using DWDM
Single Mode Optical Fiber in Rof System Using DWDMSingle Mode Optical Fiber in Rof System Using DWDM
Single Mode Optical Fiber in Rof System Using DWDMIJERA Editor
 
Performance Analysis of Wireless Networks With MDQOS
Performance Analysis of Wireless Networks With MDQOSPerformance Analysis of Wireless Networks With MDQOS
Performance Analysis of Wireless Networks With MDQOSIJERA Editor
 
Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...
Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...
Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...IJERA Editor
 
Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...
Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...
Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...IJERA Editor
 

Destaque (20)

6563.nuclear models
6563.nuclear models6563.nuclear models
6563.nuclear models
 
Infinity rankine
Infinity rankineInfinity rankine
Infinity rankine
 
Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...
Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...
Enhancing the Performance of 75mw Steam Power Plant with Second Law Efficienc...
 
GLOBAL CEMENT ARTICLE
GLOBAL CEMENT ARTICLEGLOBAL CEMENT ARTICLE
GLOBAL CEMENT ARTICLE
 
Master's Thesis Report
Master's Thesis ReportMaster's Thesis Report
Master's Thesis Report
 
Make power out of your waste heat - Organic Rankine Cycle
Make power out of your waste heat - Organic Rankine Cycle Make power out of your waste heat - Organic Rankine Cycle
Make power out of your waste heat - Organic Rankine Cycle
 
Thermal engineering by rk rajput chapter 15
Thermal engineering by rk rajput   chapter 15Thermal engineering by rk rajput   chapter 15
Thermal engineering by rk rajput chapter 15
 
Ai04606213215
Ai04606213215Ai04606213215
Ai04606213215
 
Word Problem Solver for Probability
Word Problem Solver for ProbabilityWord Problem Solver for Probability
Word Problem Solver for Probability
 
Liquid crystal bio-based epoxy coating with enhanced performance
Liquid crystal bio-based epoxy coating with enhanced performanceLiquid crystal bio-based epoxy coating with enhanced performance
Liquid crystal bio-based epoxy coating with enhanced performance
 
Single Mode Optical Fiber in Rof System Using DWDM
Single Mode Optical Fiber in Rof System Using DWDMSingle Mode Optical Fiber in Rof System Using DWDM
Single Mode Optical Fiber in Rof System Using DWDM
 
N046018089
N046018089N046018089
N046018089
 
Performance Analysis of Wireless Networks With MDQOS
Performance Analysis of Wireless Networks With MDQOSPerformance Analysis of Wireless Networks With MDQOS
Performance Analysis of Wireless Networks With MDQOS
 
H49034147
H49034147H49034147
H49034147
 
Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...
Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...
Enhancement in Power Quality With Grid Interconnection of Renewable Energy So...
 
L411018386
L411018386L411018386
L411018386
 
B411010819
B411010819B411010819
B411010819
 
M046037378
M046037378M046037378
M046037378
 
E046012533
E046012533E046012533
E046012533
 
Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...
Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...
Thermal Instability of Chemically Reacting Maxwell Fluid in a Horizontal Poro...
 

Semelhante a Performance Analysis of a Shell Tube Condenser for a Model Organic Rankine Cycle for Use in Geothermal Power Plant

A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat ExchangersA Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangersijtsrd
 
CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...
CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...
CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...ijtsrd
 
Analysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical FinsAnalysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical FinsIRJET Journal
 
Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...
Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...
Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...ijsrd.com
 
Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...
Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...
Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...IRJET Journal
 
IRJET- Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...
IRJET-  	  Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...IRJET-  	  Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...
IRJET- Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...IRJET Journal
 
J047077085
J047077085J047077085
J047077085inventy
 
Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...
Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...
Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...IJERA Editor
 
Comparative Study of ECONOMISER Using the CFD Analysis
Comparative Study of ECONOMISER Using the CFD Analysis Comparative Study of ECONOMISER Using the CFD Analysis
Comparative Study of ECONOMISER Using the CFD Analysis IJMER
 
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...IRJET Journal
 
Study on Effect of Twisted Tape Insert Geometry in Heat Exchanger
Study on Effect of Twisted Tape Insert Geometry in Heat ExchangerStudy on Effect of Twisted Tape Insert Geometry in Heat Exchanger
Study on Effect of Twisted Tape Insert Geometry in Heat Exchangerijtsrd
 
Experimentation of Heat Pipe Used In Nano-Fluids
Experimentation of Heat Pipe Used In Nano-FluidsExperimentation of Heat Pipe Used In Nano-Fluids
Experimentation of Heat Pipe Used In Nano-Fluidspaperpublications3
 
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin InclinationsCFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin InclinationsIJERA Editor
 

Semelhante a Performance Analysis of a Shell Tube Condenser for a Model Organic Rankine Cycle for Use in Geothermal Power Plant (20)

A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat ExchangersA Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
 
CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...
CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...
CFD Analysis of Heat Transfer Enhancement in Shell and Tube Type Heat Exchang...
 
D031201025031
D031201025031D031201025031
D031201025031
 
Analysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical FinsAnalysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical Fins
 
Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...
Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...
Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental a...
 
Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...
Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...
Heat Transfer Analysis of a Biomimetic Plate Heat Exchanger with Bird Feather...
 
IRJET- Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...
IRJET-  	  Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...IRJET-  	  Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...
IRJET- Thermal Analysis of Corrugated Plate Heat Exchanger by using Ansys...
 
J047077085
J047077085J047077085
J047077085
 
Ijmet 10 01_108
Ijmet 10 01_108Ijmet 10 01_108
Ijmet 10 01_108
 
Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...
Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...
Experimental Investigation on the Heat Transfer Coefficient of the Thermosyph...
 
Comparative Study of ECONOMISER Using the CFD Analysis
Comparative Study of ECONOMISER Using the CFD Analysis Comparative Study of ECONOMISER Using the CFD Analysis
Comparative Study of ECONOMISER Using the CFD Analysis
 
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
 
M012628386
M012628386M012628386
M012628386
 
M012628386
M012628386M012628386
M012628386
 
IJET-V2I6P2
IJET-V2I6P2IJET-V2I6P2
IJET-V2I6P2
 
Study on Effect of Twisted Tape Insert Geometry in Heat Exchanger
Study on Effect of Twisted Tape Insert Geometry in Heat ExchangerStudy on Effect of Twisted Tape Insert Geometry in Heat Exchanger
Study on Effect of Twisted Tape Insert Geometry in Heat Exchanger
 
W04405127131
W04405127131W04405127131
W04405127131
 
Kn3618041809
Kn3618041809Kn3618041809
Kn3618041809
 
Experimentation of Heat Pipe Used In Nano-Fluids
Experimentation of Heat Pipe Used In Nano-FluidsExperimentation of Heat Pipe Used In Nano-Fluids
Experimentation of Heat Pipe Used In Nano-Fluids
 
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin InclinationsCFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
 

Último

Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
Electronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfElectronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfme23b1001
 
Risk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfRisk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfROCENODodongVILLACER
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxk795866
 
Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...121011101441
 
8251 universal synchronous asynchronous receiver transmitter
8251 universal synchronous asynchronous receiver transmitter8251 universal synchronous asynchronous receiver transmitter
8251 universal synchronous asynchronous receiver transmitterShivangiSharma879191
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfAsst.prof M.Gokilavani
 
Churning of Butter, Factors affecting .
Churning of Butter, Factors affecting  .Churning of Butter, Factors affecting  .
Churning of Butter, Factors affecting .Satyam Kumar
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...asadnawaz62
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxbritheesh05
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEINFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEroselinkalist12
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 

Último (20)

Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
Electronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfElectronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdf
 
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
 
Risk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfRisk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdf
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptx
 
Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...
 
8251 universal synchronous asynchronous receiver transmitter
8251 universal synchronous asynchronous receiver transmitter8251 universal synchronous asynchronous receiver transmitter
8251 universal synchronous asynchronous receiver transmitter
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
 
Churning of Butter, Factors affecting .
Churning of Butter, Factors affecting  .Churning of Butter, Factors affecting  .
Churning of Butter, Factors affecting .
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptx
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEINFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 

Performance Analysis of a Shell Tube Condenser for a Model Organic Rankine Cycle for Use in Geothermal Power Plant

  • 1. Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 www.ijera.com 141 | P a g e Performance Analysis of a Shell Tube Condenser for a Model Organic Rankine Cycle for Use in Geothermal Power Plant Haile Araya Nigusse1, Hiram M. Ndiritu1, Robert Kiplimo1 1Department of Mechanical Engineering, Jomo Kenyatta University of Agriculture and Technology, Kenya ABSTRACT The global energy demand increases with the economic growth and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining. In addition to this harmful combustion byproducts are resulting global warming. However, the increase of environmental concerns and energy crisis can be minimized by sustainable utilization of the low to medium temperature heat resources. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. Heat exchangers are the main components of the Organic Rankine Cycle power plant which receives heat energy from the heat source to evaporate and condense the low boiling temperature organic working fluid which in turn drives the turbine to generate power. This paper presents a simplified approach to the design, fabrication and performance assessment of a shell tube heat exchanger designed for condenser in a model Organic Rankine Cycle geothermal power plant. The design involved sizing of heat exchanger (condenser) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated geothermal brine. The results of the experiment indicated that the heat exchanger is thermally suitable for the condenser of the model power plant. Keywords - Shell tube heat Exchanger, Heat transfer Co-efficient, LMTD. I. Introduction Energy consumption increases with growth in economies and population. The increase in energy demand will occur mainly in developing countries, where economic growth rates are high and people are shifting from biomass energy sources like wood and agricultural waste to electricity. However, the increase of environmental concerns and energy crisis has resulted in need for a sustainable approach to the utilization of the earth's energy resources. Worldwide, geothermal power plants have a capacity of about 12 GW power generations as of 2013 and in practice supply only about 0.3% of global power demand [1]. However, the conventional geothermal power plants utilize the high temperature and pressure geo-fluid and operate at low efficiency due to the heat loss in the exhausted steam and brine. The Organic Rankine Cycle power plant is a very attractive option for utilization of low-grade geothermal heat sources for power generation. Heat exchangers are the main components of the Organic Rankine Cycle geothermal power plant to receives heat energy from the hot water (brine) and vaporize and condense the low boiling temperature organic working fluid which drives the turbine to generate power. This paper presents design, fabrication and performance assessment test of the shell and tube heat exchanger designed for the condenser of a model Organic Rankine Cycle power plant. Performance tests of the heat exchanger were conducted by relating the inlet and outlet temperatures and the overall heat transfer coefficient to the rate of heat transfer between the working fluid (n-pentane) and the cooling water. Heat exchanger is an apparatus or equipment built for efficient heat transfer between two or more fluid streams at different temperatures. The shell tube heat exchanger is widely used in many binary cycle power plants. This widespread application can be justified by the availability of codes and standards for design and fabrication; it can be manufactured from a wide variety of materials and ability to be produced in the widest variety of sizes and styles. Moreover, It can be designed for a wide range of limits on the operating temperature and pressure [2, 3]. A typical counter flow shell and tube heat exchanger is shown in figure 1 RESEARCH ARTICLE OPEN ACCESS
  • 2. Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 www.ijera.com 142 | P a g e Figure 1: Counter flow shell and tube heat exchanger [1] The three most commonly used types of shell and tube heat exchanger designs are fixed tube sheet, U-tube, and the floating head type. In all types, the front end head is stationary, while the rear-end head could be either stationary or floating depending upon the thermal stresses in the shell, tube, or tube sheet due to temperature differences as a result of heat transfer. The heat exchangers are built in accordance with three mechanical standards that specify design, fabrication, and materials of unfired shell and tube heat exchangers. The two most common heat exchanger design problems are those of sizing and rating of the heat exchanger [4]. Different types of heat exchangers have been developed to meet the widely varying application based on, operating principles, flow arrangement, compactness, number of fluids and constructional design features. Among the heat exchangers are plate, shell tube and shell coil heat exchangers. Shell and tube heat exchangers are basically non compact exchangers. Generally the Heat transfer surface area per unit volume is high ranging from about 50m2/m3 to 100m2/m3. Thus, they require a considerable amount of space, supporting structure, and higher capital and installation costs. The shell and tube heat exchangers are more effective for applications in which compactness is not a priority [4]. Madhawa [5] investigated the at plate and shell tube heat exchangers and found that at plate type heat exchangers are effective in the evaporator and condenser when considering low-temperature heat sources in which large heat exchanger area (per unit power output) is required. The plate type heat exchangers are preferred due to their compactness and high heat transfer co-efficient which result to less heat transfer area than would be needed using shell and tube heat exchanger. However, at plate exchanger involves high manufacturing cost and maintenance cost. Hence it affects the overall cost of the power plant. Bambang [6] also compared the at plate and shell tube heat exchangers and found that the shell tube type is advantageous due to simplicity in geometry, well established design procedure, can be constructed from a wide range of materials, uses well-established fabrication techniques and is easily cleaned. Moreover the shell tube heat exchanger can be designed and manufactured locally from a wide range of materials. However the heat transfer optimization and minimizing the pressure drop within the shell and tube exchanger need to be addressed. The design of heat exchangers involves establishing the right flow configuration of interacting fluids. Parallel and counter flows are the two common flow configuration of a shell tube heat exchanger. The counter flow configuration is the predominantly preferred flow direction in liquid to liquid heat exchangers since it results in a higher temperature difference driving the heat transfer within the heat exchanger, smaller heat transfer surface area required [7]. Moreover counter flow configuration is most effective design when there is a temperature cross. A temperature cross occurs when the desired outlet temperature of one fluid is between the inlet and outlet temperatures of the other fluid [8]. Furthermore, various studies have been carried out on optimization of the performance of shell and tube heat exchangers using the performance parameters approach. The heat transfer coefficient values are evaluated using the log mean temperature difference (LMTD) method from the temperature difference and the heat transfer area for known inlet and outlet temperature heat exchangers [9]. Thundil et al. [10] investigated the effect of inclination of baffles in the shell by simulating a model shell and tube heat exchanger. He compared the impact of baffle inclination on fluid flow, pressure drop and the heat transfer characteristics of a shell tube heat exchanger using three different inclination angles (0o, 10o and 20o). They concluded that shell and tube heat exchanger with 20o baffle inclination angle results in better performance compared to 10o and 0o inclination angles. A. Singh et al. [11] also conducted an experimental analysis on the performance of a shell tube heat exchanger with segmented baffles at three different orientations (0o, 30o and 60o). They analyzed the system for laminar flow with varying Reynold number and concluded that the heat transfer coefficient increases with increase in Reynold number in shell tube heat exchanger for both hot fluid and cold fluids. They observed that, with the introduction of the baffles, the heat transfer coefficient increases leading to more heat transfer rate due to introduction of swirl and more convective surface area.
  • 3. Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 www.ijera.com 143 | P a g e In general, conventional shell tube heat exchangers result in high shell side pressure drop and formation of recirculation zones near the baffles. To overcome the challenge helical baffles, which gives better performance than single segmental baffles, can be used. But these baffles involve high manufacturing and maintenance cost. Hence the effectiveness and cost must be considered in the heat exchanger design [10]. II. Methodology 2.1 Heat exchanger selection Heat is transferred from one fluid to other in the heat exchanger. The process was studied by taking into account the energy balance. Studies in the application of heat exchangers leads to the selection of three important attributes related to the performance of ORC. Which are heat transfer area, overall heat transfer coefficient and temperature difference [13]. Different type of heat exchanger (plates, tubular, shell and tube etc) can be used for the condenser of an Organic Rankine Cycle geothermal power plant. For indirect heat transfer between two fluids, the shell tube heat exchangers are more effective. In this study, due to the advantages of fairly simple geometry, well established design procedure, can be fabricated from a wide range of materials, uses well established fabrication techniques and ease of cleaning, a shell tube type heat exchanger was selected for the condenser of the model power plant. The design of heat exchanger involves establishing the right flow configuration of interacting fluids. Parallel flow and counter flows are the two most commonly used flow configuration of shell tube heat exchanger. The counter-flow configuration is the predominantly preferred flow direction in liquid to liquid heat exchangers since it results in a higher temperature difference driving the heat transfer within the heat exchanger, smaller heat transfer surface area required. Moreover counter flow configuration is most effective design when there is a temperature cross. A temperature cross occurs when the desired outlet temperature of one fluid is between the inlet and outlet temperatures of the other fluid. Figure 2: The design of copper tube configuration and baffle spacing The design of the condenser is a fixed tube counter flow shell and tube heat exchanger as shown in figure 1. Moreover, the fluids flow pattern in the exchanger is in such way that the cooling water flows in the tube side and the secondary fluid (n-pentane) condenses in the shell side of the heat exchanger. This type of fluid pattern allows fouling fluid to flow through the tubes (easier to clean) and the organic working fluid (n-pentane) to flow through the shell side where a turbulent flow is obtained on the shell side due the baffles. 2.2 Design and construction of the heat exchanger In design of short heat exchangers it is reasonable to assume a constant value of overall heat transfer coefficient (U). The log-mean temperature difference (LMTD) method is useful for the sizing and rating of heat exchanger of known mass flow rate and range of temperature difference between the inlet and outlet of fluid streams. The following equations have been used in relating the heat transfer surface area through which heat flow occurs under the driving force of temperature difference, amount of heat transferred and overall heat transfer coefficient. Figure 3: Schematic diagram of flow configuration of counter flow shell and tube heat exchanger
  • 4. Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 www.ijera.com 144 | P a g e (1) Where heat capacity rate for hot or cold fluid, C = mCp, and Cp is specific heat capacity at constant pressure. During the heat transfer process energy is conserved therefore for the cold and hot fluid; (2) Where heat capacity rate for hot or cold fluid C = mcp, subscripts hi and ho represent inlet and outlet of hot fluid respectively and Ci and Co represent cold fluid inlet and outlet respectively. Heat transferred in the process (Q) may be related to the overall heat transfer coefficient U and the mean temperature difference ΔTlmtd by: (3) Where A is heat transfer surface area and ΔTlmtd is the log mean temperature difference. The log mean temperature difference of the heat exchanger can be determined as follows: (4) Where, ΔT1 and ΔT2 represent the temperature differences at the inlet and exit of the heat exchanger respectively as shown in figure 3. The heat exchanger was designed using the design equations 1-4. The details of the designed shell tube heat exchanger are shown in Table 1. Figure 2 shows the assembly of the copper tubes to the tube sheet and the baffles placed on the respective position. Table 1: Design details of the condenser Description Tube side Shell side Fluid pattern pentane cooling water Number of tubes 21 Total tube length 8.4 Tube diameter (DO/DI)(mm) 12.7/10.9 150 Heat transfer area (m2) 0.2634 Number of pass 1 Tube configuration 300 triangular Tube pitch 16 Material Copper Galvanized steel The shell of the heat exchanger was constructed by rolling a plate of galvanized steel. The plate was cut to a rectangular shape of size 471mm by 750mm and four holes were drilled for the inlet and outlet of the two fluids before the plate was rolled. The plate was then rolled and brazed using gas welding and produced a cylinder of 150mm in diameter and height of 750mm. The tube sheets were made from a round at piece of galvanized steel with holes drilled for the tube ends in a precise location and pattern relative to one another. Figure 4: The shell and tube heat exchanger tube bundle Two baffles were also provided as shown with a baffle pitch of 150mm. The optimum baffle pitch (spacing between segmental baffles) and the baffle cut were applied to determine the cross flow velocity and hence the rate of heat transfer and minimize pressure drop. A baffle spacing of 0.2 to 1 times the inside shell diameter is commonly used. A baffle cut of 20 to 25% provides a good heat-transfer with the reasonable pressure drop [14]. A 20% baffle cut was applied for this particular shell tube heat exchanger. The % cut for segmental baffle refers to the cut away height from its diameter. Copper tubes were cut at a length of 400mm and each tube was brazed using a gas welding to the hole provided on the tube sheet to produce a tube bundle as shown in figure 4. The tube bundle was then inserted to the main shell and the two tube sheets were brazed to provide air tight joints. 2.3 Heat exchanger leakage test It is important to test the leak tightness of the heat exchanger at the operating temperature and pressure before carrying out a performance test. Leak tightness test was carried out to ensure that the heat exchanger performs adequately at the design temperatures and pressures. The heat exchanger was tested for its leak tightness at room temperature and the design pressure of 2.5 bar using water circulating
  • 5. Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 www.ijera.com 145 | P a g e in the tube side. After inspecting for the leak, water was circulated on the shell side of the exchanger with the help of a water pump. During the tests, leaks were mainly detected on the welded joints between the shell and the tube sheet, copper tubes and tube sheet joints and on the joints of the inlet and exit pipes of the heat exchanger. A sealing material called STAG was applied on the leaking edges and test was carried again until no further leakage was detected. STAG is easy break, smooth consistency and lead-free jointing compound. It is commonly used for sealing of high pressure and temperature pipes. It is a non-poisonous and resists to organic chemicals. 2.4 Performance test of the heat exchanger The performance test unit consists of an overhead cooling water tank, the heat exchanger, secondary fluid tank and feed pump. A schematic sketch showing valves, pressure gauges, flow meters, and the location of temperature sensors is given in Figure 5. The cooling water flow rate was controlled by opening valve HV1. The feed pump supplies the organic working fluid (n-pentane) at constant flow rate of 0.12kg/s to the exchanger (evaporator) through the flow meter and condenses on the shell side in a counter-current to the cooling water flow. The condensed working fluid from the exchanger was then directed back to the secondary fluid tank. Figure 5: Schematic sketch of the heat exchanger performance test experiment. The length of one test section was set to be two minutes. A set of four thermocouples were provided to record pertinent temperatures at the inlet and exit of each fluid as shown in the figure 5. The thermocouples were connected to a data logger of type TDS-530. The data logger was set to print each temperature in the test section of two minutes. A set of five measurements were conducted by varying the cooling water mass flow rate and maintaining the secondary fluid (n-pentane) flow rate constant. The temperature indicators on the data logger displayed the following temperatures.  T1 Cooling water inlet temperature to condenser  T2 Cooling water exit temperature from condenser  T3 Secondary fluid temperature inlet to condenser  T4 Secondary fluid temperature exit from condenser 2.5 Experimental procedure The overhead cooling water tank was filled with water. The valve HV1 was opened and cooling water was allowed into the shell side of the heat exchanger (condenser). The feed pump was switched on and the secondary fluid (n-pentane) allowed to flow into the tube side of the heat exchanger. It was waited until the steady state has been reached. At steady state, all the four temperatures and flow rates of cooling water and secondary fluid were noted down. The flow rate of cooling water was changed and waited for new steady state to be reached. 2.6 Thermal parameters evaluation The following relations were applied to evaluate the remaining performance parameters of the heat exchanger. The LMTD method was used since the inlet and outlet temperatures of both the cooling water and the secondary fluid are known. (5) (6) Where subscripts c and h represent cold and hot fluid respectively, i and o represent for inlet and outlet respectively. Heat capacity rate for hot or cold fluid C = mCp, A is the heat transfer area and U is overall heat transfer coefficient and TLMTD is the log mean temperature difference. 1. Pressure drop of pentane, ıPp = Pi - Po 2. Cooling water temperature difference, ıTw = Twi - Two 3. Pentane Temperature difference, ıTp = Tpi - Tpo 4. Log mean temperature difference TLMTD for counter flow heat exchanger: Where: Twi is cooling water inlet temperature; Two is Cooling water outlet temperature, Tpi is pentane inlet temperature, and Tpo is pentane outlet temperature.
  • 6. Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 www.ijera.com 146 | P a g e III. Results and discussions Performance test of the heat exchanger (condenser) was carried out. Three parameters were studied to investigate the performance of the heat exchanger. The heat transferred, overall heat transfer coefficient and pressure drop within the shell and tube heat exchanger having secondary fluid (n-pentane) in tube side and cooling water in the shell side in counter flow configuration. Five experiments were conducted at different cooling water mass flow rates. Figure 6: Variation of overall heat transfer coefficient with increase in cooling water mass flow rate In the process, increase in the flow rate of cooling water resulted in increase in the overall heat transfer coefficient as can be seen from curve in figure 6. The curve shows that an increase of cooling water flow rate from 0.15kg/s to 0.35kg/s increased the overall heat transfer coefficient of the heat exchanger by 1.21%. This is because increase in the mass flow rate of cooing water increases the heat energy transferred. Since the specific heat remains almost constant, cooling water outlet temperature should increase to comply with law of conservation of energy and hence as the flow rate of the cooling water is increased, the tube side overall heat transfer coefficient also increases. Figure 7: Variation of heat duty with increase in cooling water mass flow rate Similarly, the variation of heat transferred (heat duty) with mass flow rate of the cooling water is shown in Figure 7. The curve shows that heat transferred increased by 4.26% with an increase of cooling water flow rate from 0.15kg/s to 0.35kg/s. This is because increase in the cooling water mass flow rate increases over all heat transfer coefficient in a lower rate than the heat energy transferred. Figure 8: Variation of pressure drop with increase in cooling water mass flow rate The curve in figure 8 shows the variation of pressure drop values with increase in cooling water mass flow rate. It was observed that the pressure drop increased from 1.5kPa to 3.5kPa in the tube side and in the shell side pressure drop increased from 1.3kPa to 2.4kPa with increase in cooling water flow rate in heat exchanger. Shell and tube heat exchangers generally experience pressure drop mainly due to friction, change in thermodynamic properties like viscosity and density through the heat exchanger as a result of heating or cooling, acceleration and deceleration of fluid with change is flow cross section etc. This pressure drop may increase pumping power and may affect the service time of structural
  • 7. Haile Araya Nigusse et al Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 8( Version 3), August 2014, pp.141-147 www.ijera.com 147 | P a g e components of the heat exchanger. However compared to rate of change of the heat transferred the rate of increase in pressure drop is reasonable. IV. Conclusion Shell and tube heat exchanger was designed; fabricated and experimental test was conducted to examine the performance of the heat exchanger (condenser). The performance parameters, the overall heat transfer coefficient, heat transferred and pressure drop at different cooling water mass flow rates were evaluated. The main points are summarized as follows.  The pressure drop gradually increased with increase in cooling water flow rate in heat exchanger. This may increase pumping power which in turn decreases the efficiency of the model power plant. However, the rate of increase in pressure drop is very small compared to rate of increase in heat transfer. Hence the rate of increase in pump work is reasonably minimal.  The results of the performance test indicated that the overall heat transfer coefficient is greater than the assumed overall heat transfer coefficient of heat exchanger in the design. This implies that the heat exchanger is thermally suitable for the evaporator of the model power plant.  The results of the performance test revealed that the heat exchanger is working satisfactorily under standard conditions. The test results were compared with the design data and the performance parameters reasonably close to the design performance data. Thus the heat exchanger is reliable and can be applied for the evaporator of the model Organic Rankine Cycle power plant. References [1] A. Hadidi, “A new design approach for shell and tube heat exchangers using competitive algorithm (ICA) from economic point of view,” Energy Conversion and Management, vol. 67, pp. 66 - 74, 2013 [2] S. Vangapally, “Design, Fabrication and Testing of FRP shell Counter-flow heat Exchanger,” International Journal of Engineering Science and Innovative Technology (IJESIT), vol. 3. 2014. [3] R. K. Shah, “Heat Exchangers” University of Kentueky [4] H.D. Madhawa Hettiarachchi, “Optimum design criteria for an Organic Rankine cycle using low-temperature geothermal heat sources,” Energy, vol. 32, pp 1698- 1706,2007 [5] Bambang P., “Model of Binary Cycle Power Plant using Brine as thermal Energy Source and Development Potential in Sibayaka,” International Journal of Electrical and Computer Science IJECS-IJENS, vol. 11, pp. 02. [6] T. Kuppan, Heat Exchanger Design Handbook. Marcel Dekker,200 [7] Akash Pandey, “Performance Analysis of a Compact Heat Exchanger,” Master’s thesis, National Institute of technology Rourkela, 2011. [8] F.P Incropera and D. P.Dewitt, Introduction to Heat Transfer. New York, USA, 2006. [9] B. Gay “Shell-side heat transfer in baffled cylinderical Shell and tube exchangers an electrochemical mass- trasfer modelling technique, ” international Journal of Heat and Mass transfer, vol. 19, pp. 995-1002, 1976 [10] M. A. Mehrabian, “The overall hat transfer characterstics of doublé pepe hat exchanger: Comparison of experimental data with preditions of standard correlations,” International Journal of Engineering, vol. 15, pp. 395-406, 2012 [11] R. Thundil, “Shell side numerical analysis of a Shell and tube heat exchanger considering the effect of bafle inclination angle on fluid flow,” International Journal of Thermal Science. vol. 16, no.4, pp. 1165- 1174 [12] Amarjit Singh and Satbir S. Sehgal, “Thermohydraulic Analysis of Shell and tube Heat Exchanger with Segmental Baffles,” Hindawi Publishing corporation, vol.(Article ID) 548676, pp. 5 pages, 2013 [13] Umesh K ,”Optimization and selection of Organic Rankine cycle for low grade heat recovery by using graph theoretical approach,” Department of Mechanical Engineering, Faculty of Engineering and Technology, Jamia Millia Isllia, New Delhi, India. [14] Patel, “Shell and Tube Heat Exchanger Thermal Design with optimization of mass flow rate and baffle spacing,” International Journal of Advanced Engineering Research and Studies, E- ISSN2249-8974