SlideShare uma empresa Scribd logo
1 de 49
A SEMINAR ON
TENSEGRITY STRUCTURE-
RESPONSE TO DYNAMIC LOADING
BY
SHRIDHAN (170918023)
Kurilpa Bridge,
Brisbane, Australia
CONTENT
• INTRODUCTION
• ADVANTAGES
• DISADVANTAGES
• APPLICATION
• METHODOLOGY
• CONCLUSION
• REFERENCES
INTRODUCTION
• Tensegrity means Tension Integrity structure.
• It is one type of truss structure which consist of pin-jointed tension and
compression members.
• A strict tensegrity is composed of a set of continuous cables in tension, and
a set of discontinuous struts in compression.
• Tensegrity structure are spatial, reticulated and light weight structures.
• Stability is provided by the self stress state in tensioned and compressed
members.
• The simple tensegrity structure is a 3-bar tensegrity system contains 3 struts
and 12 pre-stress cables.
[2, 4, 5, 7]
• Tensegrity structures exist as a
pre-stressed stable connection
of bars and strings. [4]
Fig-1: The Simplest 3-bar Tensegrity system, 1: Bar, 2:
Declining string, 3: Upper level string, 4: Lower level string, [11]
ADVANTAGES
• It offering maximum amount of strength for a given amount of building
material.
• Due to short length of components in compression, buckling is very rare.
• Very useful in terms of absorption of shocks and seismic vibration so
desirable in areas where earthquake are a problem.
• For large construction, the process would be easy to carry out, since the
structure is self-scaffolding.
• It provides minimal mass structures for a variety of loading conditions.
[2, 10]
DISADVANTAGES
• Difficulties during manufacturing process.
• There is no specific standard design code.
• In addition to material cost, tensegrities require additional pre-tensioning
labour and careful assembling on site.
• Higher labour cost.
[7]
APPLICATION
• It is used for light weight structures.
• Solar facades and wind generators.
• Satellite solar panel.
• Light weight footbridge, roof truss, domes, stadium.
• This tensegrity concept is also used in architecture, biology, robotics and
aerospace engineering.
• Elegant appearance with high strength to weight ratios.
[7, 10]
1. Static and dynamic analysis of Tensegrity
structures. Part-1. Nonlinear equation of motion by
Murakami (2001)
• Objectives:
A linearized equation of motion are used to conduct modal analysis of a three
bar Tensegrity module and a Tensegrity beam.
• Tensegrity structure:
Here, Bars and cables are assumed to be made of steel with Young’s modulus Y0
=200 GPa, and mass density ρ=7860 kg/m3. Height of three bar module is 1 m.
The radius of cables 0.001 m and the inner and outer radii of hollow circular
cylindrical bars 0.018 m and 0.022 m.
The element force of cables changed from -200 N to -1000 N.
The corresponding compressive force in bar was between 0.4 and 1.99 MPa.
For beam six-stage Tensegrity system is considered. It built by stacking the three
bar modules with alternating twisting directions and by adding additional
strings.
Methodology:
The dynamic response can be investigated by conducting modal analysis.
Linearized equations of motion is given by:
MLŸ+KTY-fL(t)=ç(0)
Where, ML= mass matrix,
KT= Tangent stiffness matrix,
fL= External force vector
Consider a harmonic motion of the form : u=ū exp(iωt),
Where, ū=amplitude, ω=angular frequency.
Ktū=ω2Mū
Fig-2: Three bar Tensegrity module
• Conclusion:
Table-1: The natural frequency of the lowest four modes for various pre-stress.
Fig-3: (a) The first mode and (b) The second mode of the Three-bar Tensegrity module.
• In the first mode the axial
Deformation accomplished
by adjacent counter-twisting
sets of three bars. Therefore
the first mode is globally
Longitudinal mode.
• The second mode appears as
A flexural mode.
• The first mode represents
an infinitesimal mechanism
mode of beam so natural
frequency is much smaller Fig-4: (a) The first mode and (b) the second mode of a six-stage
than second mode. Tensegrity beam.
2. Design optimization and dynamic analysis of
a tensegrity-based footbridge by Nizar et al. (2010)
• Objectives:
This paper presents design optimization and dynamic analysis of a tensegrity-
based civil structure.
A pentagonal hollow rope is used as a structural system for a 21.6 m-span
footbridge.
The dynamic behaviour of the tensegrity-based footbridge is also analysed.
Footbridge model:
The used steel grade is S355 with modulus of elasticity of 210,000 MPa and yield
stress of 355 MPa. Cables are made of stainless steel with a modulus of elasticity
of 120,000 Mpa. Footbridge deck weight assumed as 100 kg/m2.
This footbridge is designed so as to have 2.0 width internal space for walking and
a clearance of 2.5 m.
A six pentagon module used which contains 15 struts and 30 cables.
The length of pentagon is 360 cm, Length of diagonal and intermediate struts are
488 cm. Layer cable have a length of 330 cm and while x-cables are 250 cm
length.
As per Swiss code SIA 261: Consider UDL of 4kN/m2 and Point load 10kN.
Considering uniform wind pressure of 1.3kN/m2 to 1.4kN/m2.
The nodes of the structure at both extremities are supposed to be fixed in all
three translation directions.
Fig-5: The tensegrity footbridge
Fig-6: Illustration of pentagon module members
• Methodology:
The linearized equation of motion of a tensegrity structure is given as:
[M] {ű} + [KT] {u} = {F}
Where, [M] and [KT] are mass and tangent stiffness matrix.
{F} is a applied load vector,
{ű} and {u} are vector of nodal acceleration and displacement.
For a small harmonic motion {u} = {ū} sin(ωt)
Where, ω= angular frequency, {ū}= Displacement amplitude vector.
[KT] {ū}= ω2[M]{ū}
The weight of footbridge deck is taken into account in the mass matrix.
The self weight of the pedestrian is taken as 2pedestrian/m2 to 4pedestrian/m2.
• Load combination:
1. For Ultimate Limit State (ULS):
1.35G+1.5Q+0.8P+0.6W and 1.35G+1.5Q+1.2P+0.6W
2. For Serviceability of Limit State (SLS):
1.0G+0.4Q+1.0P+0.6W
Where,
G= Dead load, Q= Live load, P= Loads due to self stress, W= Wind load
• Conclusion:
• This study shows that tensegrity
system with connected compression Table-2: Natural frequency of Tensegrity footbridge
elements could compete with
traditional structural system
• Eigen-frequency analysis results
showed that the tensegrity based
footbridge can withstand
dynamic loads induced by a small
number of pedestrians.
Fig-7: Variation of natural frequency w.r.t. the no. of
pedestrian on the footbridge
• Fundamental frequency of tensegrity footbridge is not directly influenced by the
self-stress level.
• Frequency influenced by other design parameters such as the c/s sizes of x-
cables.
Fig-8: Variation of natural frequency w.r.t. the Fig-9: Variation of natural frequency w.r.t. the
c/s area of diagonal struts. c/s area of layer cable.
Fig-10: Variation of natural frequency w.r.t. the Fig-11: Variation of natural frequency w.r.t. the
c/s area of intermediate struts. c/s area of x-cable.
3. Dynamic behaviour and vibration control of a
Tensegrity structures by Hadj Ali, and Smith (2010)
• Objectives:
Dynamic behaviour of the Tensegrity structure is experimentally and analytically
identified through testing under dynamic excitation.
Laboratory testing is carried out for multiple self-stress levels and for different
excitation frequencies.
• Tensegrity structure:
There was 5 modules and rest on 3 supports. Surface area=15 m2, Height=1.2 m,
Distributed DL=300 N/m2, There is composed of 30 struts and 120 tendons.
Struts are fibre reinforced polymer tubes with modulus of elasticity of 28 GPa,
and a specific mass of 2420 Kg/m2 with dia. Of 60 mm and c/s area of 703 mm2.
Tendons are stainless steel cables with modulus of elasticity of 115 GPa and c/s
area of 13.85 mm2.
Also equipped with 10 active actuated struts are used for strut length
controlling by the way self-stress state in Tensegrity structure.
• Methodology:
• Analytical Method:
1. Equation of motion.
2. Stiffness matrix is a combination of
Linear stiffness matrix (K) and
Geometrical stiffness matrix (Kg).
3. Convert the mass and the stiffness
Matrix to global co-ordinates. Fig-12: Experimental Tensegrity system (model)
4. The generalised Eigen problem is then obtained considering a small harmonic
motion of the form: u=ū sin(ωt)
Where, ω=Angular frequency and ū=Amplitude vector.
Ktū=ω2Mū
Evaluate the first 5 natural frequencies is studied with respect to the self stress
level.
Then active strut length varied from 1295.5 mm to 1308.5 mm by the steps of 1
mm. This length changes the geometry of the system.
• Free vibration Test:
The load is applied and suddenly removed and measured the displacement.
The load value, Loaded node and
Measured nodes shown in table.
Table-3: Loading for free vibration testing
• Forced vibration test:
The shaker is used in this study was an electro-magnetic device composed of an
electric motor to a linearly activated mass.
For all test the shaker was connected to node-43 and displacement measured at
the top surface nodes.
Stress levels are varied around a reference stress (Ref) through increments of mm
elongations and contractions.
Fig-13: Active struts of tensegrity structure Fig-14: Basic module of Tensegrity structure.
• Conclusion:
For Analytical model:
Table-4: Natural frequency for FEM method
Due to active strut movement: Fig-15: Number of slack cables for different struts
Fig-16: Tension in a reference cable for different active strut movements
• Movements
Table-5: Natural frequencies compared with
Free vibration
Fig-17: First natural frequency for different active strut movement.
Fig-18: Time history of vertical displacement of node 39 (600 N at Node-16)
Fig-19: Time history of vertical displacement of node 50 (600 N at Node-16)
• Comparison with theoretical and experimental data
Fig-20: Evaluations of first natural frequency with respect to self-stress level
4. Analysis of tensegrity structures subjected to
dynamic loading using a Newmark approach by
Faroughi and Lee (2015)
• Objective:
The main objective is to highlight the Newmark approach, as a direct time
integration scheme, can be adopted to investigate the behaviour of tensegrity
structures subjected to dynamic loading.
• Assumptions:
1. The materials are assumed linear elastic and members are prismatic.
2. Struts are elements that carry compressive forces.
3. Strings are elements that carry only axial tensile forces.
4. The tensegrity systems are subjected to external load only at nodes.
• Methodology:
Three numerical examples are considered, Two examples are 3-D grid structure
and the other is 2-D cantilever problem.
1. 6 x 6 quadruplex tensegrity model
2. 5 x 4 quadruplex tensegrity model
3. 3 module cantilever model
• Assume Boundary conditions:
1) The one lower corner node is completely fixed,
2) All nodes along the two edges are fixed in the Z and Y directions only.
• From the equation of motion:
• Here Mg, Cg, and KT
g are respectively mass, damping and tangent stiffness
matrices in global direction and F is external dynamic loading.
KT
g = KE
g + KG
g
• KT
g is composed of 2 parts. (1) KE
g material stiffness matrix and
(2) KG
g geometrical stiffness matrix.
Where, Cl = β1 ml +β2 KT
l
Here β1 and β2 denotes Rayleigh damping coefficients.
• Initial neglect damping and external force vector.
ω2= (KT
g )(Mg )-1
• From this equation calculate the eigenvalues for all three types of models.
Newmark’s time integration formula:
Where, ∆t= time interval,
α and β= Constant for estimation approach,
This Newmark’s method is stable if β≥0.5 and α≥0.5β
• Out of 3 models first discussing 5 x 4 quadruplex model.
This structure composed of 79 nodes, 209 cables and 80 struts.
The harmonic load applied in a form of: f(t)= f0 sin(2πω1t)
Where, f0 = 10 N, magnitude of harmonic input.
ω1= 2.2023 Hz, First Eigen value of Tensegrity structure
Then analyse the structure up to 10 s with time step 10e-4 s.
Fig-21: (5 X 4) quadruplex modules
Table-6: Properties of module parameters
• Results:
Fig-22: Behaviour of the 5x4 tensegrity grid under external loads
Table-7. Comparison the first six eigen values of tensegrity grid structure
Comparison between all three 6 x 6 quadruplex model, 5 x 4 quadruplex model
and 3-module cantilever beam.
Table-8: Initial properties for all three models
Hggghgh
Fig-23: 2D 3-module cantilever model
Fig-24: 3D 6 x 6 quadruplex module.
Conclusion
• The effect of damping and slackening condition on the dynamic analysis of
tensegrity structure were addressed.
• Through comparison with classical method, Newmark method is efficient to
solve the linearized tensegrity structure.
5. Dynamic behaviour and vibration mitigation
of a spatial Tensegrity beam by Feng et al. (2018)
• Objectives:
This paper focuses on employing an efficient control strategy to vibration
mitigation for a spatial Tensegrity beam.
To evaluate the differences between the nonlinear and linear models.
• Assumptions:
1. Cables and struts are connected by pin joins,
2. Strut members carry compressive forces,
3. Cable members only carry axial tensile forces,
4. The external loads only act on the nodes of whole system,
5. The local and global bucking of struts are neglected.
• Methodology:
Consider 5 single quadruplex modules consisting 28 nodes, 56 cables and 20 struts
as shown in Fig. 1.
The Boundary conditions are: Node 1 is fixed in all direction, Node-2 has motion
along Z-axis, Node-26 is only fixed in Z-direction, Node-27 is free to move in Y-
direction.
• Table-9: Geometric and mechanical Fig-25: Spatial quadruplex beam with 5 units
Properties of beam
Dynamic load applied: F(t)=8sin(2t+50) in all direction.
Time step: 0.02 s
Unit-3 (U3) was selected for load and displacement calculation.
In the U3 unit node-13 and node-16 are selected for results of displacement and for
force calculation a cable (node 11-16) and a strut (node 11-15) was used.
There are 5 different cases depends on the values of α and β which are the
coefficient for weighting matrices.
Based on the position of actuator there are 5 different cases.
Table-10: Control scenario for struts and cables
Table-11: Initial forces for spatial Tensegrity beam
• Conclusion:
Fig-26: Response of displacement scenario A: (a) full record of displacement of node 13, (b) zoomed view 40–50
s of node 13, (c) full record of displacement of node 16, (d) zoomed view 40–50 s of node 16.
Fig-27: Response of displacement scenario A: (a) full record of displacement of node 13, (b) zoomed view 40–
50 s of node 13, (c) full record of displacement of node 16, (d) zoomed view 40–50 s of node 16.
• The dynamic response of nonlinearTensegrity system are depends on the actuator
number, placement, and parameters of linear quadratic regulator.
• The placement of actuators in struts give better performance than in cable for both
displacement and internal force.This is mainly due to weight of strut.
• For a largeTensegrity systems, the controls using continuous cables seems much more
reasonable.
Table-12: Response of displacement scenario A
Conclusion
• The stability and natural frequency of tensegrity structure is directly depends on
the length of cables.
• Tensegrity structures promise to be highly efficient in the ratio of material to
both performance and maintenance.
• It is the light weight structure so material time saving.
• It is acts as a scaffolding so no need to use a scaffolding.
• There was no any specific code related to tensegrity structure so design of
structure is critical.
REFERENCES
[1] H. Murakami, Static and dynamic analysis of Tensegrity structures. Part-1.
Nonlinear equation of motion, International Journal of Solids and
Structures, 38 (2001) 3599-3613.
[2] R. E. Skelton et. al, An introduction to the mechanics of Tensegrity
structures, IEEE conference, (2001) USA.
[3] C. Sultan, M. Corless, E. Skelton, Linear dynamics of Tensegrity structures,
Engineering Structures, 24 (2002) 671-685.
[4] D. Williamson, R. E. Skelton, J. Han, Equilibrium conditions of a tensegrity
structure, International Journal of Solids and Structures, 40 (2003) 6347-
6367.
[5] J. Y. Zhang, M. Ohsaki, Y. Kanno, A direct approach to design of geometry
and forces of tensegrity systems, International Journal of Solids and
Structures, 43 (2006) 2260-2278.
[6] N. Bel Hadj Ali, I.F.C. Smith, Dynamic behavior and vibration control of a
tensegrity structure, International Journal of Solids and Structures, 47
(2010) 1285-1296.
[7] N. Bel Hadj Ali, L. Rhode Barbarigos, Alberto A. Pascual Albi, Ian F. C. Smith,
Design optimization and dynamic analysis of a tensegrity-based footbridge,
Engineering Structures, 32 (2010) 3650-3659.
[8] S. Faroughi, J. Lee, Analysis of tensegrity structures subject to dynamic
loading using a Newmark approach, Journal of Building Engineering, 2
(2015) 1–8.
[9] F. Fabbrocino, G. Carpentieri, Three-dimensional modeling of the wave
dynamics of tensegrity lattices, Composite Structures, 173 (2017) 9–16.
[10] M. C. Cimmino et. al, Composite solar facades and wind generators with
Tensegrity architecture, Composites Part-B, 115 (2017) 275-281.
[11] H. Liu, J. Zhang, M. Ohsaki, New 3-bar prismatic tensegrity units, Composite
Structures, 184 (2018) 306-313.
[12] Xiaodong Feng, Mohammad S. Miah, Yaowen Ou, Dynamic behaviour and
vibration mitigation of a spatial tensegrity beam, Engineering Structures, (2018).
Warnow tower,
Germany
White rhino, Japan

Mais conteúdo relacionado

Mais procurados

Composite structure of concrete and steel.
Composite structure of concrete and steel.Composite structure of concrete and steel.
Composite structure of concrete and steel.Suhailkhan204
 
Types of structures
Types of structuresTypes of structures
Types of structurescarnipe
 
Stucture large span area
Stucture large span areaStucture large span area
Stucture large span areaAbhishek Mewada
 
structure analysis by PUC GRP 3
structure analysis by PUC GRP 3structure analysis by PUC GRP 3
structure analysis by PUC GRP 3promitchowdhury1
 
Structural systems notes
Structural systems notesStructural systems notes
Structural systems notesAaqib Iqbal
 
Lateral stability of building structures
Lateral stability of building structuresLateral stability of building structures
Lateral stability of building structuresWolfgang Schueller
 
Classification of Loads on Structures
Classification of Loads on StructuresClassification of Loads on Structures
Classification of Loads on Structureszameer1979
 
Multi storey structural steel structures
Multi storey structural steel structuresMulti storey structural steel structures
Multi storey structural steel structuresThomas Britto
 
Large span structures
Large span structuresLarge span structures
Large span structuresaduiti
 
Buckling restrained braced frames
Buckling restrained braced framesBuckling restrained braced frames
Buckling restrained braced framesashlinvilson
 
Analysis of cable stayed bridges
Analysis of cable stayed bridgesAnalysis of cable stayed bridges
Analysis of cable stayed bridgesParamaAthmeka
 
BRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKEBRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKESajid Iqbal
 
Analysis and design of high rise building frame using staad pro
Analysis and design of high rise building frame using staad proAnalysis and design of high rise building frame using staad pro
Analysis and design of high rise building frame using staad proeSAT Journals
 
DESIGN PHILOSOPHY OF LSM.pptx
DESIGN PHILOSOPHY OF LSM.pptxDESIGN PHILOSOPHY OF LSM.pptx
DESIGN PHILOSOPHY OF LSM.pptxprasath k s
 
Profiled deck composite floors
Profiled deck composite floorsProfiled deck composite floors
Profiled deck composite floorsElamathy Murugan
 
Truss bridge final presentation
Truss bridge final presentationTruss bridge final presentation
Truss bridge final presentationkaiumbhai
 

Mais procurados (20)

Composite structure of concrete and steel.
Composite structure of concrete and steel.Composite structure of concrete and steel.
Composite structure of concrete and steel.
 
Types of structures
Types of structuresTypes of structures
Types of structures
 
Structures presentation
Structures presentationStructures presentation
Structures presentation
 
Stucture large span area
Stucture large span areaStucture large span area
Stucture large span area
 
Tuned mass damper
Tuned mass damperTuned mass damper
Tuned mass damper
 
structure analysis by PUC GRP 3
structure analysis by PUC GRP 3structure analysis by PUC GRP 3
structure analysis by PUC GRP 3
 
Structural systems notes
Structural systems notesStructural systems notes
Structural systems notes
 
Lateral stability of building structures
Lateral stability of building structuresLateral stability of building structures
Lateral stability of building structures
 
Types of loads
Types of loadsTypes of loads
Types of loads
 
Classification of Loads on Structures
Classification of Loads on StructuresClassification of Loads on Structures
Classification of Loads on Structures
 
Multi storey structural steel structures
Multi storey structural steel structuresMulti storey structural steel structures
Multi storey structural steel structures
 
Large span structures
Large span structuresLarge span structures
Large span structures
 
Buckling restrained braced frames
Buckling restrained braced framesBuckling restrained braced frames
Buckling restrained braced frames
 
Analysis of cable stayed bridges
Analysis of cable stayed bridgesAnalysis of cable stayed bridges
Analysis of cable stayed bridges
 
BRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKEBRACED STEEL FRAMES IN EARTHQUAKE
BRACED STEEL FRAMES IN EARTHQUAKE
 
Buckling types
Buckling typesBuckling types
Buckling types
 
Analysis and design of high rise building frame using staad pro
Analysis and design of high rise building frame using staad proAnalysis and design of high rise building frame using staad pro
Analysis and design of high rise building frame using staad pro
 
DESIGN PHILOSOPHY OF LSM.pptx
DESIGN PHILOSOPHY OF LSM.pptxDESIGN PHILOSOPHY OF LSM.pptx
DESIGN PHILOSOPHY OF LSM.pptx
 
Profiled deck composite floors
Profiled deck composite floorsProfiled deck composite floors
Profiled deck composite floors
 
Truss bridge final presentation
Truss bridge final presentationTruss bridge final presentation
Truss bridge final presentation
 

Semelhante a Tensegrity structure

Design and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridgesDesign and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridgeseSAT Journals
 
Design and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridgesDesign and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridgeseSAT Journals
 
Forces on a Magnet Moving Past Figure-Eight Coils
Forces on a Magnet Moving Past Figure-Eight CoilsForces on a Magnet Moving Past Figure-Eight Coils
Forces on a Magnet Moving Past Figure-Eight CoilsChristopher Klaus
 
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 StrandEnergy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strandtheijes
 
Monitoring of strain and seismic vibrations in structures
Monitoring of strain and seismic vibrations in structuresMonitoring of strain and seismic vibrations in structures
Monitoring of strain and seismic vibrations in structureskalyanabooshnam
 
Behavior of RC Beams Retrofitted/Strengthened With External Post-Tension System
Behavior of RC Beams Retrofitted/Strengthened With External Post-Tension SystemBehavior of RC Beams Retrofitted/Strengthened With External Post-Tension System
Behavior of RC Beams Retrofitted/Strengthened With External Post-Tension SystemINFOGAIN PUBLICATION
 
Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...
Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...
Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...IRJET Journal
 
Axial Forces of a Half-spherical Space Truss Structure with Opening
Axial Forces of a Half-spherical Space Truss Structure with OpeningAxial Forces of a Half-spherical Space Truss Structure with Opening
Axial Forces of a Half-spherical Space Truss Structure with OpeningIRJET Journal
 
Behaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical ModelsBehaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical ModelsIJERDJOURNAL
 
strength of materials TUTORIAL 1
strength of materials TUTORIAL 1strength of materials TUTORIAL 1
strength of materials TUTORIAL 1musadoto
 

Semelhante a Tensegrity structure (20)

I012274853
I012274853I012274853
I012274853
 
Design and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridgesDesign and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridges
 
Design and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridgesDesign and analysis of stress ribbon bridges
Design and analysis of stress ribbon bridges
 
Forces on a Magnet Moving Past Figure-Eight Coils
Forces on a Magnet Moving Past Figure-Eight CoilsForces on a Magnet Moving Past Figure-Eight Coils
Forces on a Magnet Moving Past Figure-Eight Coils
 
Ijsea04031013
Ijsea04031013Ijsea04031013
Ijsea04031013
 
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 StrandEnergy’s Method for Experimental Life Prediction of a 1 + 6 Strand
Energy’s Method for Experimental Life Prediction of a 1 + 6 Strand
 
Structural analysis 2 lab manual
Structural analysis 2 lab manualStructural analysis 2 lab manual
Structural analysis 2 lab manual
 
Monitoring of strain and seismic vibrations in structures
Monitoring of strain and seismic vibrations in structuresMonitoring of strain and seismic vibrations in structures
Monitoring of strain and seismic vibrations in structures
 
Behavior of RC Beams Retrofitted/Strengthened With External Post-Tension System
Behavior of RC Beams Retrofitted/Strengthened With External Post-Tension SystemBehavior of RC Beams Retrofitted/Strengthened With External Post-Tension System
Behavior of RC Beams Retrofitted/Strengthened With External Post-Tension System
 
F012213639
F012213639F012213639
F012213639
 
Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...
Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...
Effect of Prestressing Force, Cable Profile and Eccentricity on Post Tensione...
 
Project 2b (1) (2)
Project 2b  (1) (2)Project 2b  (1) (2)
Project 2b (1) (2)
 
Gh3511131117
Gh3511131117Gh3511131117
Gh3511131117
 
Axial Forces of a Half-spherical Space Truss Structure with Opening
Axial Forces of a Half-spherical Space Truss Structure with OpeningAxial Forces of a Half-spherical Space Truss Structure with Opening
Axial Forces of a Half-spherical Space Truss Structure with Opening
 
2581
25812581
2581
 
Instron machine
Instron machineInstron machine
Instron machine
 
Behaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical ModelsBehaviour Analysis of Corroded Wires Based on Statistical Models
Behaviour Analysis of Corroded Wires Based on Statistical Models
 
[IJET-V2I1P8] Authors:Mr. Mayur k Nemade , Porf. S.I.Kolhe
[IJET-V2I1P8] Authors:Mr. Mayur k Nemade , Porf. S.I.Kolhe[IJET-V2I1P8] Authors:Mr. Mayur k Nemade , Porf. S.I.Kolhe
[IJET-V2I1P8] Authors:Mr. Mayur k Nemade , Porf. S.I.Kolhe
 
Graduation project presentation
Graduation project presentationGraduation project presentation
Graduation project presentation
 
strength of materials TUTORIAL 1
strength of materials TUTORIAL 1strength of materials TUTORIAL 1
strength of materials TUTORIAL 1
 

Último

Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Christo Ananth
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdfSuman Jyoti
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSISrknatarajan
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxfenichawla
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...roncy bisnoi
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756dollysharma2066
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdfankushspencer015
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSUNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSrknatarajan
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01KreezheaRecto
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesPrabhanshu Chaturvedi
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 

Último (20)

Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICSUNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
UNIT-IFLUID PROPERTIES & FLOW CHARACTERISTICS
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 

Tensegrity structure

  • 1. A SEMINAR ON TENSEGRITY STRUCTURE- RESPONSE TO DYNAMIC LOADING BY SHRIDHAN (170918023) Kurilpa Bridge, Brisbane, Australia
  • 2. CONTENT • INTRODUCTION • ADVANTAGES • DISADVANTAGES • APPLICATION • METHODOLOGY • CONCLUSION • REFERENCES
  • 3. INTRODUCTION • Tensegrity means Tension Integrity structure. • It is one type of truss structure which consist of pin-jointed tension and compression members. • A strict tensegrity is composed of a set of continuous cables in tension, and a set of discontinuous struts in compression. • Tensegrity structure are spatial, reticulated and light weight structures. • Stability is provided by the self stress state in tensioned and compressed members. • The simple tensegrity structure is a 3-bar tensegrity system contains 3 struts and 12 pre-stress cables. [2, 4, 5, 7]
  • 4. • Tensegrity structures exist as a pre-stressed stable connection of bars and strings. [4] Fig-1: The Simplest 3-bar Tensegrity system, 1: Bar, 2: Declining string, 3: Upper level string, 4: Lower level string, [11]
  • 5. ADVANTAGES • It offering maximum amount of strength for a given amount of building material. • Due to short length of components in compression, buckling is very rare. • Very useful in terms of absorption of shocks and seismic vibration so desirable in areas where earthquake are a problem. • For large construction, the process would be easy to carry out, since the structure is self-scaffolding. • It provides minimal mass structures for a variety of loading conditions. [2, 10]
  • 6. DISADVANTAGES • Difficulties during manufacturing process. • There is no specific standard design code. • In addition to material cost, tensegrities require additional pre-tensioning labour and careful assembling on site. • Higher labour cost. [7]
  • 7. APPLICATION • It is used for light weight structures. • Solar facades and wind generators. • Satellite solar panel. • Light weight footbridge, roof truss, domes, stadium. • This tensegrity concept is also used in architecture, biology, robotics and aerospace engineering. • Elegant appearance with high strength to weight ratios. [7, 10]
  • 8. 1. Static and dynamic analysis of Tensegrity structures. Part-1. Nonlinear equation of motion by Murakami (2001) • Objectives: A linearized equation of motion are used to conduct modal analysis of a three bar Tensegrity module and a Tensegrity beam. • Tensegrity structure: Here, Bars and cables are assumed to be made of steel with Young’s modulus Y0 =200 GPa, and mass density ρ=7860 kg/m3. Height of three bar module is 1 m. The radius of cables 0.001 m and the inner and outer radii of hollow circular cylindrical bars 0.018 m and 0.022 m. The element force of cables changed from -200 N to -1000 N. The corresponding compressive force in bar was between 0.4 and 1.99 MPa.
  • 9. For beam six-stage Tensegrity system is considered. It built by stacking the three bar modules with alternating twisting directions and by adding additional strings. Methodology: The dynamic response can be investigated by conducting modal analysis. Linearized equations of motion is given by: MLŸ+KTY-fL(t)=ç(0) Where, ML= mass matrix, KT= Tangent stiffness matrix, fL= External force vector Consider a harmonic motion of the form : u=ū exp(iωt), Where, ū=amplitude, ω=angular frequency. Ktū=ω2Mū Fig-2: Three bar Tensegrity module
  • 10. • Conclusion: Table-1: The natural frequency of the lowest four modes for various pre-stress. Fig-3: (a) The first mode and (b) The second mode of the Three-bar Tensegrity module.
  • 11. • In the first mode the axial Deformation accomplished by adjacent counter-twisting sets of three bars. Therefore the first mode is globally Longitudinal mode. • The second mode appears as A flexural mode. • The first mode represents an infinitesimal mechanism mode of beam so natural frequency is much smaller Fig-4: (a) The first mode and (b) the second mode of a six-stage than second mode. Tensegrity beam.
  • 12. 2. Design optimization and dynamic analysis of a tensegrity-based footbridge by Nizar et al. (2010) • Objectives: This paper presents design optimization and dynamic analysis of a tensegrity- based civil structure. A pentagonal hollow rope is used as a structural system for a 21.6 m-span footbridge. The dynamic behaviour of the tensegrity-based footbridge is also analysed. Footbridge model: The used steel grade is S355 with modulus of elasticity of 210,000 MPa and yield stress of 355 MPa. Cables are made of stainless steel with a modulus of elasticity of 120,000 Mpa. Footbridge deck weight assumed as 100 kg/m2.
  • 13. This footbridge is designed so as to have 2.0 width internal space for walking and a clearance of 2.5 m. A six pentagon module used which contains 15 struts and 30 cables. The length of pentagon is 360 cm, Length of diagonal and intermediate struts are 488 cm. Layer cable have a length of 330 cm and while x-cables are 250 cm length. As per Swiss code SIA 261: Consider UDL of 4kN/m2 and Point load 10kN. Considering uniform wind pressure of 1.3kN/m2 to 1.4kN/m2. The nodes of the structure at both extremities are supposed to be fixed in all three translation directions.
  • 14. Fig-5: The tensegrity footbridge Fig-6: Illustration of pentagon module members
  • 15. • Methodology: The linearized equation of motion of a tensegrity structure is given as: [M] {ű} + [KT] {u} = {F} Where, [M] and [KT] are mass and tangent stiffness matrix. {F} is a applied load vector, {ű} and {u} are vector of nodal acceleration and displacement. For a small harmonic motion {u} = {ū} sin(ωt) Where, ω= angular frequency, {ū}= Displacement amplitude vector. [KT] {ū}= ω2[M]{ū} The weight of footbridge deck is taken into account in the mass matrix. The self weight of the pedestrian is taken as 2pedestrian/m2 to 4pedestrian/m2.
  • 16. • Load combination: 1. For Ultimate Limit State (ULS): 1.35G+1.5Q+0.8P+0.6W and 1.35G+1.5Q+1.2P+0.6W 2. For Serviceability of Limit State (SLS): 1.0G+0.4Q+1.0P+0.6W Where, G= Dead load, Q= Live load, P= Loads due to self stress, W= Wind load
  • 17. • Conclusion: • This study shows that tensegrity system with connected compression Table-2: Natural frequency of Tensegrity footbridge elements could compete with traditional structural system • Eigen-frequency analysis results showed that the tensegrity based footbridge can withstand dynamic loads induced by a small number of pedestrians. Fig-7: Variation of natural frequency w.r.t. the no. of pedestrian on the footbridge
  • 18. • Fundamental frequency of tensegrity footbridge is not directly influenced by the self-stress level. • Frequency influenced by other design parameters such as the c/s sizes of x- cables. Fig-8: Variation of natural frequency w.r.t. the Fig-9: Variation of natural frequency w.r.t. the c/s area of diagonal struts. c/s area of layer cable.
  • 19. Fig-10: Variation of natural frequency w.r.t. the Fig-11: Variation of natural frequency w.r.t. the c/s area of intermediate struts. c/s area of x-cable.
  • 20. 3. Dynamic behaviour and vibration control of a Tensegrity structures by Hadj Ali, and Smith (2010) • Objectives: Dynamic behaviour of the Tensegrity structure is experimentally and analytically identified through testing under dynamic excitation. Laboratory testing is carried out for multiple self-stress levels and for different excitation frequencies. • Tensegrity structure: There was 5 modules and rest on 3 supports. Surface area=15 m2, Height=1.2 m, Distributed DL=300 N/m2, There is composed of 30 struts and 120 tendons. Struts are fibre reinforced polymer tubes with modulus of elasticity of 28 GPa, and a specific mass of 2420 Kg/m2 with dia. Of 60 mm and c/s area of 703 mm2.
  • 21. Tendons are stainless steel cables with modulus of elasticity of 115 GPa and c/s area of 13.85 mm2. Also equipped with 10 active actuated struts are used for strut length controlling by the way self-stress state in Tensegrity structure. • Methodology: • Analytical Method: 1. Equation of motion. 2. Stiffness matrix is a combination of Linear stiffness matrix (K) and Geometrical stiffness matrix (Kg). 3. Convert the mass and the stiffness Matrix to global co-ordinates. Fig-12: Experimental Tensegrity system (model)
  • 22. 4. The generalised Eigen problem is then obtained considering a small harmonic motion of the form: u=ū sin(ωt) Where, ω=Angular frequency and ū=Amplitude vector. Ktū=ω2Mū Evaluate the first 5 natural frequencies is studied with respect to the self stress level. Then active strut length varied from 1295.5 mm to 1308.5 mm by the steps of 1 mm. This length changes the geometry of the system. • Free vibration Test: The load is applied and suddenly removed and measured the displacement. The load value, Loaded node and Measured nodes shown in table. Table-3: Loading for free vibration testing
  • 23. • Forced vibration test: The shaker is used in this study was an electro-magnetic device composed of an electric motor to a linearly activated mass. For all test the shaker was connected to node-43 and displacement measured at the top surface nodes. Stress levels are varied around a reference stress (Ref) through increments of mm elongations and contractions. Fig-13: Active struts of tensegrity structure Fig-14: Basic module of Tensegrity structure.
  • 24. • Conclusion: For Analytical model: Table-4: Natural frequency for FEM method Due to active strut movement: Fig-15: Number of slack cables for different struts Fig-16: Tension in a reference cable for different active strut movements
  • 25. • Movements Table-5: Natural frequencies compared with Free vibration Fig-17: First natural frequency for different active strut movement.
  • 26. Fig-18: Time history of vertical displacement of node 39 (600 N at Node-16)
  • 27. Fig-19: Time history of vertical displacement of node 50 (600 N at Node-16)
  • 28. • Comparison with theoretical and experimental data Fig-20: Evaluations of first natural frequency with respect to self-stress level
  • 29. 4. Analysis of tensegrity structures subjected to dynamic loading using a Newmark approach by Faroughi and Lee (2015) • Objective: The main objective is to highlight the Newmark approach, as a direct time integration scheme, can be adopted to investigate the behaviour of tensegrity structures subjected to dynamic loading. • Assumptions: 1. The materials are assumed linear elastic and members are prismatic. 2. Struts are elements that carry compressive forces. 3. Strings are elements that carry only axial tensile forces. 4. The tensegrity systems are subjected to external load only at nodes.
  • 30. • Methodology: Three numerical examples are considered, Two examples are 3-D grid structure and the other is 2-D cantilever problem. 1. 6 x 6 quadruplex tensegrity model 2. 5 x 4 quadruplex tensegrity model 3. 3 module cantilever model • Assume Boundary conditions: 1) The one lower corner node is completely fixed, 2) All nodes along the two edges are fixed in the Z and Y directions only.
  • 31. • From the equation of motion: • Here Mg, Cg, and KT g are respectively mass, damping and tangent stiffness matrices in global direction and F is external dynamic loading. KT g = KE g + KG g • KT g is composed of 2 parts. (1) KE g material stiffness matrix and (2) KG g geometrical stiffness matrix. Where, Cl = β1 ml +β2 KT l Here β1 and β2 denotes Rayleigh damping coefficients. • Initial neglect damping and external force vector. ω2= (KT g )(Mg )-1 • From this equation calculate the eigenvalues for all three types of models.
  • 32. Newmark’s time integration formula: Where, ∆t= time interval, α and β= Constant for estimation approach, This Newmark’s method is stable if β≥0.5 and α≥0.5β • Out of 3 models first discussing 5 x 4 quadruplex model. This structure composed of 79 nodes, 209 cables and 80 struts. The harmonic load applied in a form of: f(t)= f0 sin(2πω1t) Where, f0 = 10 N, magnitude of harmonic input. ω1= 2.2023 Hz, First Eigen value of Tensegrity structure Then analyse the structure up to 10 s with time step 10e-4 s.
  • 33. Fig-21: (5 X 4) quadruplex modules Table-6: Properties of module parameters
  • 34. • Results: Fig-22: Behaviour of the 5x4 tensegrity grid under external loads Table-7. Comparison the first six eigen values of tensegrity grid structure
  • 35. Comparison between all three 6 x 6 quadruplex model, 5 x 4 quadruplex model and 3-module cantilever beam. Table-8: Initial properties for all three models
  • 36. Hggghgh Fig-23: 2D 3-module cantilever model Fig-24: 3D 6 x 6 quadruplex module.
  • 37. Conclusion • The effect of damping and slackening condition on the dynamic analysis of tensegrity structure were addressed. • Through comparison with classical method, Newmark method is efficient to solve the linearized tensegrity structure.
  • 38. 5. Dynamic behaviour and vibration mitigation of a spatial Tensegrity beam by Feng et al. (2018) • Objectives: This paper focuses on employing an efficient control strategy to vibration mitigation for a spatial Tensegrity beam. To evaluate the differences between the nonlinear and linear models. • Assumptions: 1. Cables and struts are connected by pin joins, 2. Strut members carry compressive forces, 3. Cable members only carry axial tensile forces, 4. The external loads only act on the nodes of whole system, 5. The local and global bucking of struts are neglected.
  • 39. • Methodology: Consider 5 single quadruplex modules consisting 28 nodes, 56 cables and 20 struts as shown in Fig. 1. The Boundary conditions are: Node 1 is fixed in all direction, Node-2 has motion along Z-axis, Node-26 is only fixed in Z-direction, Node-27 is free to move in Y- direction. • Table-9: Geometric and mechanical Fig-25: Spatial quadruplex beam with 5 units Properties of beam
  • 40. Dynamic load applied: F(t)=8sin(2t+50) in all direction. Time step: 0.02 s Unit-3 (U3) was selected for load and displacement calculation. In the U3 unit node-13 and node-16 are selected for results of displacement and for force calculation a cable (node 11-16) and a strut (node 11-15) was used. There are 5 different cases depends on the values of α and β which are the coefficient for weighting matrices. Based on the position of actuator there are 5 different cases.
  • 41. Table-10: Control scenario for struts and cables Table-11: Initial forces for spatial Tensegrity beam
  • 42. • Conclusion: Fig-26: Response of displacement scenario A: (a) full record of displacement of node 13, (b) zoomed view 40–50 s of node 13, (c) full record of displacement of node 16, (d) zoomed view 40–50 s of node 16.
  • 43. Fig-27: Response of displacement scenario A: (a) full record of displacement of node 13, (b) zoomed view 40– 50 s of node 13, (c) full record of displacement of node 16, (d) zoomed view 40–50 s of node 16.
  • 44. • The dynamic response of nonlinearTensegrity system are depends on the actuator number, placement, and parameters of linear quadratic regulator. • The placement of actuators in struts give better performance than in cable for both displacement and internal force.This is mainly due to weight of strut. • For a largeTensegrity systems, the controls using continuous cables seems much more reasonable. Table-12: Response of displacement scenario A
  • 45. Conclusion • The stability and natural frequency of tensegrity structure is directly depends on the length of cables. • Tensegrity structures promise to be highly efficient in the ratio of material to both performance and maintenance. • It is the light weight structure so material time saving. • It is acts as a scaffolding so no need to use a scaffolding. • There was no any specific code related to tensegrity structure so design of structure is critical.
  • 46. REFERENCES [1] H. Murakami, Static and dynamic analysis of Tensegrity structures. Part-1. Nonlinear equation of motion, International Journal of Solids and Structures, 38 (2001) 3599-3613. [2] R. E. Skelton et. al, An introduction to the mechanics of Tensegrity structures, IEEE conference, (2001) USA. [3] C. Sultan, M. Corless, E. Skelton, Linear dynamics of Tensegrity structures, Engineering Structures, 24 (2002) 671-685. [4] D. Williamson, R. E. Skelton, J. Han, Equilibrium conditions of a tensegrity structure, International Journal of Solids and Structures, 40 (2003) 6347- 6367.
  • 47. [5] J. Y. Zhang, M. Ohsaki, Y. Kanno, A direct approach to design of geometry and forces of tensegrity systems, International Journal of Solids and Structures, 43 (2006) 2260-2278. [6] N. Bel Hadj Ali, I.F.C. Smith, Dynamic behavior and vibration control of a tensegrity structure, International Journal of Solids and Structures, 47 (2010) 1285-1296. [7] N. Bel Hadj Ali, L. Rhode Barbarigos, Alberto A. Pascual Albi, Ian F. C. Smith, Design optimization and dynamic analysis of a tensegrity-based footbridge, Engineering Structures, 32 (2010) 3650-3659. [8] S. Faroughi, J. Lee, Analysis of tensegrity structures subject to dynamic loading using a Newmark approach, Journal of Building Engineering, 2 (2015) 1–8.
  • 48. [9] F. Fabbrocino, G. Carpentieri, Three-dimensional modeling of the wave dynamics of tensegrity lattices, Composite Structures, 173 (2017) 9–16. [10] M. C. Cimmino et. al, Composite solar facades and wind generators with Tensegrity architecture, Composites Part-B, 115 (2017) 275-281. [11] H. Liu, J. Zhang, M. Ohsaki, New 3-bar prismatic tensegrity units, Composite Structures, 184 (2018) 306-313. [12] Xiaodong Feng, Mohammad S. Miah, Yaowen Ou, Dynamic behaviour and vibration mitigation of a spatial tensegrity beam, Engineering Structures, (2018).