1. ENCAP SYSTEMS INC. “Encapsulating and Protecting building systems for a stronger tomorrow” NEW & OLD CONSTRUCTION
2. Test Equipment and Procedure Used by the University of Central Florida to determine the reasons for water penetrations, new and old stucco construction during heaving rains and hurricanes. ASTM C1601 - 04 Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces (ASTM C1601 - 04 2004) is a pressurized water test that simulates wind driven rain. The test measures the rate of water flow out of a closed system under a given rate of air pressure and water flow that simulates wind speed and rainfall rate respectively.
3. The Encap Group, LLC Results after ASTM Test on ENCAP SEAL on the walls at the VA hospital. .083 Gallons/ hour intrusion (.375 Gallons/ hour intrusion considered excellent)
4. Application of water intrusion equipment being installed to the walls of the VA hospital prior to the application of the ENCAP SEAL System.
5. Water curtain attached to the wall of the VA hospital prior to the application of the ENCAP SEAL water proofing system.
6. Note water running down the wall prior to the application of the ENCAP SEAL system.
8. EXAMPLES OF PRODUCT USE OUC Water Storage Tank, Lake Highland Orlando, FL WATER PROOFING ON WALLS AND ROOFS Encap Seal was applied as a roof coating this water Tank. Allowing heavy lift crane to traverse without damage to The coating. As a water proof coating on concrete / stucco walls