SlideShare uma empresa Scribd logo
1 de 97
ANIL PALAMWAR
RETIRED
CHIEF ENGINEER, KHAPERKHEDA TPS.
DIRECTOR (OPERATION) MAHAVITARAN
• NEED FOR ENERGY AUDIT.
• AUDIT PROCEEDURES
• ENERGY AUDIT –
• MACRO LEVEL
• AND
• MICRO LEVEL.
1
Energy Audit ?????
• We know Financial Audit.
• Audit of Public Enterprises.
• Balancing of Income & Expenses.
• Whether rules are followed ?
• E.A. is slightly different.
• Energy Audit deals with -
• Losses – Efficiency – Conservation
• Promotes :- Economy, competitiveness &
Environment.
2
ENERGY CONSERVATION
ENERGY IS THE CAPACITY TO DO WORK.
ENERGY IS AVAILABLE FROM
WIND-WATER-SUN -FOSSIL FUEL
MOSTLY WE WORK WITH ELECTRICAL OR THERMAL
ENERGY.
Why Conserve?
1. - RESOURCES ARE LIMITED.
2.-COST REDUCTION TO REMAIN VIABLE IN
COMPETITION.
3.- Environment - Global warming - GHGs
3
EFFICIENCY OF RANKINE CYCLE IS LIMITED TO 35-40 %.
C.C.G.T. PLANTS GO UP TO 52-55 %.Efficiency. [Combined Cycle Gas
Turbines]
SO IF HEAT IS USED DIRECTLY,
[WITHOUT CONVERTING TO ELECTRICITY],
CYCLE EFFICIENCY WILL INCREASE.
CO-GENERATION ADOPTS THIS PRINCIPLE.
Industrial units must explore the possibility of use of waste heat.
Where ever a furnace is used,
lot of waste heat is available for use in some way or other.
IN SIMPLE WORDS –
WHEN 100 M.T. OF FUEL IS USED, ONLY 40 MT IS USED TO
PRODUCE ELECTRICITY,
HEAT VALUE OF REMAINING 60 M.T. GOES UNUSED TO THE
ATMOSPHERE.
4
ALSO- CONSIDER THE SYSTEM LOSSES-
Transmission
Three Transformers-220/33; 33/11 ; 11/0.415 KV---
Efficiency=0.99 x0.99 x 0.99 =0.97 or 97%
Transmission Efficiency= 94 %,
Distribution Efficiency=85%
Motor Efficiency=80 %
Pump Efficiency = 80%
Total system Efficiency=
0.97x0.94x0.85x0.80x0.80=0.4960 or 49.60%
5
It means that for every unit consumed, two units are
generated and sent from a power station.
Conservation is therefore necessary. Waste must be
avoided .
Cost is the most powerful motivating factor for
conservation.
Maharashtra State needs approximately 300 MU of
electricity per day. (Average)
Only about 150 MU are really utilized.
Efficiency is of utmost importance.
Every process needs thorough check to identify losses.
6
Transformers- Losses within limits-e.g. MSEDCL
Motors-Pumps-Fans- e.g. Feed Pump and P.A. Fans at KPKD
TPS.
Procurement-Installation-O&M -
All these affect performance-and losses.
Ducting and its aerodynamics- Eddy formation
Selection of correct pipe dia and cleanliness of pipes.
Air conditioning- use of vapour cycles
where waste heat is used.
Properly set thermostats.
Maximum use of daylight and Natural ventilation.
7
ENERGY AUDIT
FRIENDS & ENEMIES
8
NEGATIVE FORCES
GOAL -TO REDUCE ENERGY CONSUMPTION
POSITIVE FORCES
HIGH PRICEOF ENERGY
EFFICIENTTECHNOLOGY
TAX ON ENERGY
TOP MANAGEMENTSUPPORT
ENERGY INTENSIVE INDUSTRY
NO CORPORATE ENERGY POLICY
NO AWARENESS IN THE COMPANY
INSUFFICIENTSKILLS & KNOWLEDGE
COMPETING CORPORATE POLICIES
INSUFFICIENT FUNDS
FOUR PILLARS OF ENERGY
MANAGEMENT
9
TECHNICAL ABILITY
MONITORING
SYSTEM
STRATEGY
PLAN
TOP MANAGEMENT
SUPPORT
ENERGY MANAGEMENT
MATERIAL BALANCE
10
SOLID WASTE FOR
STORAGE &
DISPOSAL
WATER / AIR
PROCESS
OPERATIONS
REUSABLE WASTE
GASEOUS EMISSION
PRODUCT
BYE PRODUCT
WASTE WATER
LIQUID WASTE FOR
STORAGE &
RAW MATERIALS
CHEMICALS
ENERGY BALANCE
11
ENERGY IN HOT RESIDUE
ENERGY IN CONDENSATE
COMPRESSED AIR
ENERGY IN COOLING
WATERENERGY IN RAW MATERIAL
ENERGY IN VAPOUR
ELECTRICITY
STEAM RADIATION LOSS
PROCESS
OPERATIONSCOOLING WATER ENERGY IN HOT PRODUCTS
12
13
14
NON Renewable Energy Sources
15
Renewable Energy Sources
16
17
It took more than 3 million years to convert to Fossil
Fuels.
INTRODUCTIONINTRODUCTION
Conventional source of energy such as coal,
oil and gas are scarce and exhaustible.
Energy prices will rise in the long run to
reflect their relative scarcity and high cost
of exploration and extraction.
Hence, all attempts must be made
expeditiously to ensure the optimal use of
the available resources to manage the
viability and availability of energy.
18
INTRODUCTION (contd.)INTRODUCTION (contd.)
 Government of India enacted the Energy
Conservation Act – 2001.
 For efficient use of energy and its conservation to
mitigate the gap between demand and supply and to
promote economic competitiveness.
 The Act provides for
 Institutionalizing and strengthening delivery
mechanisms for energy efficiency services in the
country and
 Provides the much-needed coordination between the
various organizations and stakeholders,
 Within the Government and in the private sector.
19
Enacted in October 2001Enacted in October 2001
Become effective from 1st March 2002Become effective from 1st March 2002
Bureau of Energy Efficiency (BEE) operationalizedBureau of Energy Efficiency (BEE) operationalized
from 1from 1stst
March 2002.March 2002.
MISSION OF BEEMISSION OF BEE
Develop policy and strategies with aDevelop policy and strategies with a
thrust on self regulation and marketthrust on self regulation and market
principles, within the overall framework of theprinciples, within the overall framework of the
EC Act with the primary objective of reducingEC Act with the primary objective of reducing
energy intensity of the Indian economy.energy intensity of the Indian economy. 20
1. DESIGNATED CONSUMERS1. DESIGNATED CONSUMERS
( Energy Intensive Industries and other Establishments)( Energy Intensive Industries and other Establishments)
A programme to initially focus on energy policyA programme to initially focus on energy policy
issues of energy efficiency improvement,issues of energy efficiency improvement,
 in organized sectors such asin organized sectors such as
 energy intensive industries and.energy intensive industries and.
 commercial sector,commercial sector,
 through establishment of energy managementthrough establishment of energy management
system,system,
 capacity building of energy professionals,capacity building of energy professionals,
implementation of energy audits,implementation of energy audits,
establishments of specific energy consumption normsestablishments of specific energy consumption norms
 support to consumers on providing information onsupport to consumers on providing information on
authentic energy dataauthentic energy data
21
Designated Industries Schedule - Responsibilities
 Schedule to EC Act provides list of 15 energySchedule to EC Act provides list of 15 energy
intensive industries and other establishments to beintensive industries and other establishments to be
notified as designated consumers (DC).notified as designated consumers (DC).
 Designated Consumers to -Designated Consumers to -
Appoint or designate energy managersAppoint or designate energy managers
Get energy audits conducted by accreditedGet energy audits conducted by accredited
energy auditorsenergy auditors
Implement techno-economic viableImplement techno-economic viable
recommendationsrecommendations
Comply with norms of specific energyComply with norms of specific energy
consumption fixedconsumption fixed
Submit report on steps takenSubmit report on steps taken
22
1)
Designated Consumers
Thermal Power Stations- 30,000 Million tonne of oil
equivalent (MTOE) per year and above
2) Fertilizer- 30,000 MTOE per year and above
3) Cement- 30,000 MTOE per year and above
4) Iron & Steel- 30,000 MTOE per year and above
5) Chlor-Alkali- 12,000MTOE per year and above
6) Alluminium- 7,500 MTOE per year and above
7)
Railways- One traction substation in each Zonal Railway ,
Production units and Workshops of Indian Railways having
total annual energy consumption of 30,000 MTOE or more
under Ministry of Railways
8) Textile-3,000 MTOE per year and above
9) Pulp & Paper-30,000 MTOE per year and above
23
WHY ENERGY EFFICIENCY IS IMPORTANT ?WHY ENERGY EFFICIENCY IS IMPORTANT ?
• We do something to enjoy, save money &
resources and finally because it is the LAW.
• So Energy Audit – Because,
• Depleting fossil fuel-Resources are scarce
• Optimum plant utilization-Competitiveness.
• Global warming-Carbon Credit
• Designated consumer-E.A. is Mandatory.
• Generate more energy with same quantity of
fuel 24
PERIOD STEAM
PRESSURE&
TEMPERATURE
UNIT SIZE
(MW)
TURBINE
Heat Rate
(Kcal/kWh)
Unit Heat Rate
(Kcal/kWh)/
Efficiency
1951-60 60 kg/cm2
, 482o
C 30 – 57.5 2470
1961-75 70 kg/cm2
, 496o
C to
90 ata 538o
C
60 – 100 2370
1961-75 130 ata 535/535o
C 110 – 120 2170 – 2060 2552-2423
1977-82 130 ata 535/535o
C 210
(Russian)
2060 2423/
35.4%
1983+ 150 ata 535/535o
C 210
(Siemens)
2024 2335
36.8%
1984+ 170 ata 535/535o
C 500 1950 (TDBFP) 2294
37.4%
1990+ 150 ata 535/535o
C
170 ata 538/538 o
C
210/ 250
250/ 500
1950
(MDBFP)
1950 (TDBFP)
2294
2294
THIS CHART SHOWS THE GRADUAL IMPROVEMENT
IN HEAT RATE
TO ACHIEVE ECONOMY
25
EFFICIENCY IMPROVEMENT
CAN GIVE YOU
For an average increase of 1 % in the Efficiency would
result in:-
 Coal savings of approx. 11 million tons per annum
worth Rs.13,000 Million
 CO2 reduction about 13.5 million tons per annum
 Lower generation cost per kWh- as more efficient the
unit works, the more economical it is
 1% increase in efficiency for 210 Mw unit with heat
rate 2335 kcal/kwh means heat rate improvement to
2275 kcal/kwh
26
MAJOR CAUSE OF INEFFICENCY IN POWER PLANTMAJOR CAUSE OF INEFFICENCY IN POWER PLANT
• High Flue gas exit Temp
• Excessive amount of excess air(O2)(Increases dry flue gas
loss)
• Poor Mill/Burners performance causing high unburnt
carbon in fly and bottom ash.
• Poor insulation.
• Poor house Keeping.
• Poor instrumentation and automation
27
MAJOR CAUSE OF INEFFICENCY INMAJOR CAUSE OF INEFFICENCY IN
POWER PLANTPOWER PLANT (Cont…)
• Not running the units on design parameter
• Heaters not in service or poor performance
of regenerative system
• Poor condenser vacuum
• Excessive DM water consumption- passing
and leakages
• Use of Reheat spray to control Reheat
Temperature
• Poor Cylinder Efficiency of turbine
28
CONTROLLABLE PLANT
PARAMETERS
• M.S. & R.H. Steam Temperatures
• M.S. Steam Pressure
• Condenser Vacuum
• Final Feed Water Temperature
• DP Across Feed Regulation Station
• Auxiliary Power Consumption
• Make Up Water Consumption
29
HOW TO ACHIEVE ENERGYHOW TO ACHIEVE ENERGY
EFFICIENCY ?EFFICIENCY ?
• Adopt state of the art technologies
• Adopt cutting edge technologies
• Review & Re-engineering of the existing
systems
• Bench Marking
• Energy Auditing
30
CAN WE IMPROVECAN WE IMPROVE
EFFICIENCY?EFFICIENCY?
 Yes, provided we shed the myths and
believe in applying result oriented
efforts
 Workout to identify & quantify the cost
of hidden losses
 Bring in requisite operational
behavioral change
31
SOME OF THE MYTHS
 High PLF & availability translates into
Optimum Efficiency
 Heat rate is the responsibility of Efficiency
Management Group at Stations
 Equipment maintenance to be taken-up based
on periodic overhaul schedule
 Boiler performance degradations has no
relation to Turbine Cycle performance
32
Some of the Myths contd…
• Design heat rate is the best achievable heat rate
• Efficiency tests are the same as performance guarantee
test
• Heat rate improvement requires large investment.
• Results follow immediately after testing is completed
• Heat rate is the responsibility of Energy & Efficiency
Management Group (EEMG) at Stations
• Station instruments are accurate for monitoring heat
rate parameters
33
Some of the Myths contd…
“Design” is not the best achievable performance
• Predicted performance based on Turbine Heat Balance
Diagrams and Boiler Efficiency at different loads
• ‘Design’ is based on specific ambient conditions that vary
throughout the year
• Actual initial performance could be different from design or
changes might have been made to plant
• Current performance to be compared to an achievable
‘expected’ value to establish efficiency gaps
34
SYNERGIZE OPERATION
OF UNIT
Need to clearly understand the relation between
performance & fuel, operation and design
parameters
Operational behavior and performance
Impacts of operating efficiency of Boiler, Turbine
and their auxiliaries on Net Unit Heat Rate
Maximum Achievable Load, Maintenance &
Availability
35
SOME CRITICAL FACTORS AFFECTING
BOILER PERFORMANCE
• Fuel:- Heating Value, Moisture Contents, Ash
Composition, Ash Contents,& Volatile Matter.
• Operational Parameter:- Level of Excess Air, &
operating Condition of Burner Tilt Mechanism.
• Design:- Heating input per plan area, Height of Boiler,
Platens & pendants heat transfer Surfaces, Burner & wind
Box design.
36
BEHAVIOURAL IMPACTS
• Low heat value results in over firing of fuel causing more heat
availability for super heater and re-heater thus more attempration
spray requirement. Hence increase in THR, overloading of ash
handling system, fans and increased soot blowing
• Moisture content increase causes increase in heat transfer to S.H, and
R.H. Hence again increase in attempration spray and THR (Turbine
Heat Rate)
• Ash composition and contents increases damage to pressure parts
surfaces because of melting behavior of low fusion ash temperature of
blended coal in particular
• In consistency in fired fuel characteristics results in variation in excess
air requirement thereby increasing stack loss and hence boiler
efficiency reduction, overloading of ID Fan and ultimately unit load
limitation
• High heat value causes excessive radiant heat transfer to water walls
thereby leaving lesser heat for super heater and re-heater
• .
37
Normally excess air ranges from 15% to 30% of
stoichiometric air.
• High O2 % and presence of CO at ID Fan outlet are indicator
of air in leakages and improper combustion in furnace
• Poorly effective damper control also is the cause of higher
SEC of fans both primary and secondary
• The quality and purity of feed water and make up water is also
required to be maintained in a meticulous way by limiting
blow down losses to nearly 1% and by checking the passing
and leakages of valves. However, maximum 3% of flow can
be taken as make up for these causes including soot blowing
requirements
• Soot blowing is dependent on ash contents and is unit specific.
Intelligently devised soot blowing can result in saving the fuel
BEHAVIOURAL IMPACTS
38
• Cascading effects on efficiency, loading and
availability because of following systems and
equipments performance also needed to be looked
into. The systems are:-
Fuel receiving, preparation and handling systems.
Pulverizing system
Air Heater
Fans
Electrostatic Precipitator
Fly ash handling system
Bottom ash handling system
Waste disposal system
BEHAVIOURAL IMPACTS
39
PERFORMANCE IMPACTS ON STEAM
CYCLE , UNIT HEAT RATE & OUTPUT
• Various design & operating parameters of a
unit are responsible for its cycle
performance, heat rate,& out put
40
CRITICAL FACTORS AFFECTING
CYCLE PERFORMANCE
1. Re-heater & its system pressure drop
2. Extraction line pressure drop
3. Make up
4. Turbine exhaust pressure
5. Air preheat
6. Condensate sub-cooling
7. S/H & R/H spray flows
8. Wet Bulb Temp
9. Top Heaters out of service
10. H.P. heater drain pump
11. Type of BFP drives & method of flow control 41
RH & ITS SYSTEM PRESSURE DROP….
• Every one 1% decrease in drop can improve
THR and output by 0.1% & 0.3%
respectively
• Normally designed for pressure drop
equivalent to 10% of HP exhaust pressure
• Causes are
Feed Heater abnormalities
R/H safety valve passing
42
EXTRACTION LINE PRESSURE
DROP…
• Permissible pressure drop between stage
pressure & Shell pressure is maximum 6%
• For every 2% increase in this pressure drop,
THR would be poorer by 0.09%
43
CYCLE MAKE-UP….
• Acceptable value of make up water is 3% to
offset cycle water losses
• For every 1% increase in make up 0.4%
increase in THR & 0.2% reduction on
output is there
44
EXHAUST PRESSURE…
• Increase & decrease in exhaust pressure do
affect the THR.
• Though no valid thumb rule has been devised
so far, however last stage blade design &
exhaust area of turbine do affect the impact of
changing exhaust pressure.
45
AIR PRE-HEAT….
• Air preheating of combustion air before entry to
regenerative air heater is done with either steam coil
air pre - heater or hot water pre heating coil to
maintain Average Cold End Temperature (ACET) to
escape dew point temperature complications
• Condensate retrieval is necessary to avoid
deterioration to THR depending upon unit load and
combustion pre heating duty
46
CONDENSATE SUB-COOLING…
• For 30% total flow and 2.5 deg C sub-
cooling ,an increase of 0.001% in THR can
be there for every subsequent 10% increase
in flow
47
R.H & S.H. SPRAY FLOW…
• Spray water whether drawn from BFP or
after the final heater, it is always less the
generative and less productive as well
• Every 1% spray flow, correction need to be
done in THR & load computed from the
curves supplied with the machine
48
TOP HEATER OUT OF SERVICE….
• Extraction steam flow meant for top heater
passes through the turbine thereby increasing
the output.
• But at the same time final feed water temp is
lowered resulting in poor Total Heat Return.
• More fuel must be used in the boiler to add the
sensible heat (Not imparted by the feed heater)
• The % loss increases from lowest stage (.5 to .6 )
to highest stage (1.2 to 1.5%)
• Roughly each Deg C in TTD will result in a loss
of 0.25% efficiency.
49
PERFORMANCE MONITORING
• Analyze the poor efficiency areas from previous record
• Go down to specific system and then to component
• Carry out performance/diagnostic study as suggested in
the Auditing Manual & operating manual
• Devise a unit specific efficiency control sheet for few
terminal conditions (Actual vs Design)
• Monitor once per shift to know the operating efficiency
and check any deterioration
50
Coal Handling Plant
• Coal Crushers-
• If significant quantity of coal >20 mm size is
observed on down side of crusher then it may led to
substantial decrease in mill performance.
• Identification of combination of various least power
consuming equipment and recommending merit
order operation.
• Use of natural daylight through conveyor galleries
and use of fire resistant translucent sheet.
51
Soft Starters- V.F.D.
• Explore Installation of power saver device in
major LT motors. (Conveyor belt etc.):
• Major HT /LT motors i.e. conveyors, crushers
etc. are often partially loaded & also there are
frequent starts /stops.
• Explore the possibility of providing power
saver devices (soft starters) in major motors.
52
Power Factor of Motors.
• Power factor correction possibility:
• Induction motors may have vey low power factor,
leading to lower overall efficiency.
• Capacitors connected in parallel with the motor are
used to improve the power factor.
• The PF correction reduces KVA demand,
• reduced I2
R losses in cable upstream of capacitor,
• reduced voltage drop in cables (leading to improved
voltage regulation),
• and an increase in the overall efficiency of the plant
electrical system.
53
Chemicals for Dust Suppression
• Explore the possibility of using chemicals for
reduced water spray:
• Mixing of chemical compounds in water provides
much better atomization of water spray, by
reduction in surface tension of water.
• Thus for the given application of dust
suppression, less quantity of water is sprayed
which also results into less wastage of latent heat
in the steam generator.
54
Use of Bull Dozers ?
• Maximum Mechanical Handling:
• Minimum Bulldozing: Receipt, unloading, stacking
and reclaiming and the selection of machinery should
be such that all the handling operations are
accomplished without the use of semi mechanized
means like bulldozers which are more energy
intensive equipment.
• When coal is stocked in yard for more than
incubation period (duration between coal mined and
getting self ignited), special precautions like
compacting, water spraying must be taken.
  55
Bunkering Frequency
• Reduced Number of Fillings:
• Live storage capacity of raw coal bunkers and the
filling pattern of bunkers is so planned that,
• 24 hours coal requirement of the generating units
is met by not more than two fillings per day.
• This will eliminate frequent starting and stopping
of the CHP system.
56
Boiler Scheme
57
Energy audit of Boiler
• Coal quality - composition and calorific value
• Coal milling aspects
• Combustion and excess air
• Re-heaters
• Heat recovery units – Economisers, air preheaters, etc,
• Insulation aspects
• Boiler blow down aspects- Water Chemistry
• Soot blowing aspects- Effectiveness
• Operation and maintenance features which affect the energy
efficiency
• Condition & status of boiler and their internals
• Feed water system aspects
• Air and flue gas system aspects 58
STEPS  IN  ENERGY AUDIT 
• Data collection
• Observations and Analysis
• Exploration for energy conservation measures
• Report preparation
– DATA COLLECTION
• The first step in energy audit of boiler is to collect the
design / PG test parameters pertaining to boiler,
economiser, air preheaters, coal and coal milling, soot
blowing and other key associated equipment.
59
Particulars Unit
Details at Normal
cont. rating, NCR
Make BHEL
Type Water tube single
drum
Capacity tph 627.32
Main Steam pressure kg/ cm2 155
Main Steam temperature 0C 540
Boiler efficiency % 87.16
Super heater outlet flow tph 627.32
Reheater outlet flow tph 565.6
Coal Calorific value –GCV kcal/ kg 4350
Coal consumption tph 106.2
Total combustion air tph 822
LTSH outlet temperature 0C 420
Reheater outlet temperature 0C 540
Water- economizer inlet
temperature
0C 241
Water- economizer outlet
temperature
0C 280
Oxygen content at Economizer
outlet
% 4.23
60
Unit Design NCR Actual
Make
Type
Year of Installation
Main Steam Pressure kg/ cm2
Main Steam Temperature oC
Main Steam Flow tph
Steam pressure at LTSH out let kg/ cm2
Steam temperature at reheater inlet oC
Steam temperature at reheater outlet oC
Steam pressure at reheater inlet kg/ cm2
Steam pressure at reheater outlet kg/ cm2
Steam temperature at LTSH out oC
Saturated steam temperature in drum oC
Super heater platen outlet temperature oC
Pressure drop in reheater Kg/ cm2
Super heater spray tph
Reheater Spray tph
Design ambient temperature oC
Coal consumption tph
DESIGN DATA
61
ECONOMISER DATA
Unit Design Actual
Feed water pressure at the inlet kg/ cm2
Feed water pressure at the outlet kg/ cm2
Feed water flow Tph
Feed water temperature at the inlet oC
Feed water temperature at the out let oC
Oxygen content in flue gas before
economizer %
Excess air % in flue gas before
economizer %
Exhaust gas inlet temperature oC
Exhaust gas outlet temperature oC
Exhaust gas quantity Tph
62
AIR PRE HEATER DATA
Unit Design Actual
Air quantity at APH outlet (primary) Tph
Tempering air Tph
Air heater outlet (secondary) Tph
Total combustion air Tph
Air temperature at fan outlet oC
Air outlet temperature of APH – primary oC
Air outlet temperature of APH– secondary oC
Oxygen content in flue gas before APH %
Oxygen content in flue gas after APH %
Excess air % in flue gas before
APH %
Flue gas inlet temperature oC
Flue gas outlet temperature oC
Flue gas quantity Tph
Others
63
EXHAUST GAS TEMPERATURE PROFILE
Unit Design Actual
Temperatures at different location oC
Super heater platen outlet oC
RH front inlet oC
RH rear inlet oC
SH final inlet oC
LTSH inlet oC
Economizer inlet oC
APH inlet oC
APH outlet oC
ID Fan inlet oC
ID fan outlet oC
64
BOILER HEAT BALANCE
Unit Design
Ambient temperature oC
Excess air %
Dry flue gas loss %
Hydrogen loss %
Moisture in fuel loss %
Moisture in air loss %
Unburnt combustible loss %
Radiation loss %
Un accounted loss %
Gross boiler efficiency on HHV %
Guaranteed efficiency %
65
Feed water & Boiler water limits
Unit Feed water Remarks
pH at 25oC
Oxygen – maximum ppm
Total iron- maximum ppm
Total silica – maximum ppm
Conductivity at 25oC Microsiemens
Hydrazine residual ppm
Total solids – maximum ppb
Chlorides ppm
Copper – maximum ppm
Permanganite consumption ppm
66
MILLS AND BURNERS PERFORMANCE
Unit
Requirement
at MCR
Actual Remarks
No of coal burners No
PA flow tph
No of mills in operation No
Mill loading %
Air temperature at mill inlet
after tempering
oC
Air – fuel mixture temperature
after leaving mills
oC
Total coal fired tph
Air Coal ratio
67
Mill specifications:
• Type of mill :
• Make :
• Capacity : __________tph at coal
________grind
• Fineness : ___________% through
________mesh
• Motor rating :____________kW
• Motor voltage :________ V
• No of mills :__________
• Running /Standby :_________/________
68
COAL DATA
• Design coal parameter
• Moisture :_____%
• Ash :_____%
• Volatile matter :_____%
• Fixed carbon :______%
• HGI :_____%
69
SOOT BLOWERS
Type number
Soot blowers for furnace
Soot blowers for super heaters
Soot blowers for reheaters
Soot blowers for air preheaters
Medium of blow
Steam pressure before reduction
Steam pressure after reduction
Steam consumption
70
Instruments For Energy Audit
• The following instruments are required for conducting the
boiler energy audit.
• Power Analyser: Used for measuring electrical parameters
such as kW, kVA, pf, V, A and Hz
• Temperature Indicator & Probe
• Stroboscope: To measure the speed of the driven equipment
and motor
• Sling hygrometer or digital hygrometer
• Anemometer
• Available On line instruments at the site ( Calibrated )
• Digital Manometer of suitable range and appropriate probes
for measurement of pressure head and velocity head.
•
71
• Additional pressure gauges with appropriate
range of measurement and calibrated before
audit.
• Flue gas analysers / Orsat apparatus
• Infrared pyrometers
• Pressure gauges
• Steam trap tester / Ultra sonic leak detectors
• Instrument to measure coal velocity in coal
feed pipe
72
MEASUREMENTS & OBSERVATIONS
• Average GCV of coal during audit period
• Coal analysis – ultimate and proximate
• Coal consumption details
• Performance parameters of coal mills
• Steam parameters of main steam, reheat, super
heater, LTSH (flow, pressure and temperature)
• Air – flow, temperature, pressures
73
MEASUREMENTS & OBSERVATIONS
• Flue gas – Flow, temperature and pressure
• Flue gas analysis
• Ambient temperature
• Boiler loading
• Motor electrical parameters (kW, kVA, Pf, A, V, Hz,
THD)
• Surface temperatures of insulation and boiler surfaces
• Un-burnt coal (in fly ash and bottom ash)
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97

Mais conteúdo relacionado

Mais procurados

energy Audit and types of audit
energy Audit and types of auditenergy Audit and types of audit
energy Audit and types of auditAbhishekLalkiya
 
Demand side management,
Demand side management, Demand side management,
Demand side management, Suriya Naidu
 
8: Energy Accounting, Metering & Monitoring
8: Energy Accounting, Metering & Monitoring8: Energy Accounting, Metering & Monitoring
8: Energy Accounting, Metering & MonitoringAlliance To Save Energy
 
Energy audit report presentation
Energy audit report presentationEnergy audit report presentation
Energy audit report presentationKyambadde Francisco
 
Tips for energy conservation for industries
Tips for energy conservation for industriesTips for energy conservation for industries
Tips for energy conservation for industriesKamlesh Hariyani
 
Industrial energy efficiency techniques and energy management (1)
Industrial energy efficiency techniques and energy management (1)Industrial energy efficiency techniques and energy management (1)
Industrial energy efficiency techniques and energy management (1)Anish Maman
 
Practical approach of ENERGY MANAGEMENT to sustain profitability
Practical approach of ENERGY MANAGEMENT to sustain profitabilityPractical approach of ENERGY MANAGEMENT to sustain profitability
Practical approach of ENERGY MANAGEMENT to sustain profitabilityZAINI ABDUL WAHAB
 
Energy management & audit
Energy management & auditEnergy management & audit
Energy management & auditPINAKI ROY
 
Case Study of Energy Audit
Case Study of Energy Audit Case Study of Energy Audit
Case Study of Energy Audit Darshan Vithani
 
Energy management and energy audit
Energy management and energy auditEnergy management and energy audit
Energy management and energy auditSajid Nasar
 
demand side management
demand side managementdemand side management
demand side managementKomal Nigam
 
Energy management system
Energy management systemEnergy management system
Energy management systemkashbhat
 
demand side management
demand side managementdemand side management
demand side managementanushsourabh
 
Integration of smart grid with renewable energy
Integration of smart grid with renewable energyIntegration of smart grid with renewable energy
Integration of smart grid with renewable energySAGAR D
 
Energy Auditing/ Energy conservation ppt by Varun Pratap Singh
Energy Auditing/ Energy conservation ppt by Varun Pratap SinghEnergy Auditing/ Energy conservation ppt by Varun Pratap Singh
Energy Auditing/ Energy conservation ppt by Varun Pratap SinghVarun Pratap Singh
 

Mais procurados (20)

energy Audit and types of audit
energy Audit and types of auditenergy Audit and types of audit
energy Audit and types of audit
 
Demand side management,
Demand side management, Demand side management,
Demand side management,
 
8: Energy Accounting, Metering & Monitoring
8: Energy Accounting, Metering & Monitoring8: Energy Accounting, Metering & Monitoring
8: Energy Accounting, Metering & Monitoring
 
Energy audit report presentation
Energy audit report presentationEnergy audit report presentation
Energy audit report presentation
 
Tips for energy conservation for industries
Tips for energy conservation for industriesTips for energy conservation for industries
Tips for energy conservation for industries
 
Demand side management: Demand response
Demand side management: Demand response Demand side management: Demand response
Demand side management: Demand response
 
Industrial energy efficiency techniques and energy management (1)
Industrial energy efficiency techniques and energy management (1)Industrial energy efficiency techniques and energy management (1)
Industrial energy efficiency techniques and energy management (1)
 
Energy management and audit
Energy management and auditEnergy management and audit
Energy management and audit
 
Practical approach of ENERGY MANAGEMENT to sustain profitability
Practical approach of ENERGY MANAGEMENT to sustain profitabilityPractical approach of ENERGY MANAGEMENT to sustain profitability
Practical approach of ENERGY MANAGEMENT to sustain profitability
 
Energy management & audit
Energy management & auditEnergy management & audit
Energy management & audit
 
Case Study of Energy Audit
Case Study of Energy Audit Case Study of Energy Audit
Case Study of Energy Audit
 
Energy management and energy audit
Energy management and energy auditEnergy management and energy audit
Energy management and energy audit
 
demand side management
demand side managementdemand side management
demand side management
 
Energy management system
Energy management systemEnergy management system
Energy management system
 
Energy audit ppt
Energy audit  pptEnergy audit  ppt
Energy audit ppt
 
Ems
Ems Ems
Ems
 
Energy Efficiency and Energy Audit
Energy Efficiency and Energy AuditEnergy Efficiency and Energy Audit
Energy Efficiency and Energy Audit
 
demand side management
demand side managementdemand side management
demand side management
 
Integration of smart grid with renewable energy
Integration of smart grid with renewable energyIntegration of smart grid with renewable energy
Integration of smart grid with renewable energy
 
Energy Auditing/ Energy conservation ppt by Varun Pratap Singh
Energy Auditing/ Energy conservation ppt by Varun Pratap SinghEnergy Auditing/ Energy conservation ppt by Varun Pratap Singh
Energy Auditing/ Energy conservation ppt by Varun Pratap Singh
 

Destaque

Energy efficient information and communication infrastructures in the smart g...
Energy efficient information and communication infrastructures in the smart g...Energy efficient information and communication infrastructures in the smart g...
Energy efficient information and communication infrastructures in the smart g...redpel dot com
 
Pump Audit Presentation
Pump  Audit PresentationPump  Audit Presentation
Pump Audit PresentationAnderson Cruz
 
Internal Audit Methodology
Internal Audit MethodologyInternal Audit Methodology
Internal Audit MethodologySalih Islam
 
Boiler accessories
Boiler accessoriesBoiler accessories
Boiler accessoriesrudrik joshi
 
Boiler Drum And Its Internals
Boiler Drum And Its InternalsBoiler Drum And Its Internals
Boiler Drum And Its InternalsAshrant Dass
 
A Brief Introduction to Boilers
A Brief Introduction to BoilersA Brief Introduction to Boilers
A Brief Introduction to BoilersSATYAKAM MOHAPATRA
 
Recommondation teleco(manufacturing)
Recommondation teleco(manufacturing)Recommondation teleco(manufacturing)
Recommondation teleco(manufacturing)bsmihd
 
Spanishpower point
Spanishpower pointSpanishpower point
Spanishpower pointguest3b9684d
 
Hold Hands Chicago Executive Summary
Hold Hands Chicago Executive SummaryHold Hands Chicago Executive Summary
Hold Hands Chicago Executive SummaryScott Taback
 
Espn wsummit blogpdf
Espn wsummit blogpdfEspn wsummit blogpdf
Espn wsummit blogpdfEmma Cookson
 
Knowledge Mobilization Lecture
Knowledge Mobilization LectureKnowledge Mobilization Lecture
Knowledge Mobilization LectureThom Kearney
 
Caber potensi besar
Caber potensi besarCaber potensi besar
Caber potensi besarbogasi
 

Destaque (17)

Energy conservation ppt
Energy conservation pptEnergy conservation ppt
Energy conservation ppt
 
Energy efficient information and communication infrastructures in the smart g...
Energy efficient information and communication infrastructures in the smart g...Energy efficient information and communication infrastructures in the smart g...
Energy efficient information and communication infrastructures in the smart g...
 
Pump Audit Presentation
Pump  Audit PresentationPump  Audit Presentation
Pump Audit Presentation
 
Audit Methodology
Audit MethodologyAudit Methodology
Audit Methodology
 
Internal Audit Methodology
Internal Audit MethodologyInternal Audit Methodology
Internal Audit Methodology
 
Boiler accessories
Boiler accessoriesBoiler accessories
Boiler accessories
 
Boiler Drum And Its Internals
Boiler Drum And Its InternalsBoiler Drum And Its Internals
Boiler Drum And Its Internals
 
A Brief Introduction to Boilers
A Brief Introduction to BoilersA Brief Introduction to Boilers
A Brief Introduction to Boilers
 
Energy Audit Report
Energy Audit ReportEnergy Audit Report
Energy Audit Report
 
Recommondation teleco(manufacturing)
Recommondation teleco(manufacturing)Recommondation teleco(manufacturing)
Recommondation teleco(manufacturing)
 
Spanishpower point
Spanishpower pointSpanishpower point
Spanishpower point
 
Hold Hands Chicago Executive Summary
Hold Hands Chicago Executive SummaryHold Hands Chicago Executive Summary
Hold Hands Chicago Executive Summary
 
Phuhlisa sancor 11 june 2013
Phuhlisa sancor 11 june 2013Phuhlisa sancor 11 june 2013
Phuhlisa sancor 11 june 2013
 
Espn wsummit blogpdf
Espn wsummit blogpdfEspn wsummit blogpdf
Espn wsummit blogpdf
 
Knowledge Mobilization Lecture
Knowledge Mobilization LectureKnowledge Mobilization Lecture
Knowledge Mobilization Lecture
 
Confirmation 18 & 19 done
Confirmation 18 & 19 doneConfirmation 18 & 19 done
Confirmation 18 & 19 done
 
Caber potensi besar
Caber potensi besarCaber potensi besar
Caber potensi besar
 

Semelhante a 001 conservation-Energy Audit -Methods

Energy Management System in Forging industries2
Energy Management System in Forging industries2Energy Management System in Forging industries2
Energy Management System in Forging industries2Avijit Choudhury
 
Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...
Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...
Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...The i-Capital Africa Institute
 
Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...
Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...
Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...ESD UNU-IAS
 
Energy Conservation By Mehfooz Qazi
Energy Conservation By Mehfooz QaziEnergy Conservation By Mehfooz Qazi
Energy Conservation By Mehfooz QaziIEEEP Karachi
 
Energy Efficiency for Malaysia-the way forward
Energy Efficiency for Malaysia-the way forwardEnergy Efficiency for Malaysia-the way forward
Energy Efficiency for Malaysia-the way forwardZAINI ABDUL WAHAB
 
Energy efficiency in the tennessee valley
Energy efficiency in the tennessee valleyEnergy efficiency in the tennessee valley
Energy efficiency in the tennessee valleyTNenergy
 
Modelling global macroeconomic impacts of a carbon constrained energy system ...
Modelling global macroeconomic impacts of a carbon constrained energy system ...Modelling global macroeconomic impacts of a carbon constrained energy system ...
Modelling global macroeconomic impacts of a carbon constrained energy system ...IEA-ETSAP
 
Energy Efficiency: A kenya power perspective
Energy Efficiency: A kenya power perspectiveEnergy Efficiency: A kenya power perspective
Energy Efficiency: A kenya power perspectiveACX
 
ENERGY CONSERVATION PPT by ee-63
ENERGY CONSERVATION PPT by ee-63ENERGY CONSERVATION PPT by ee-63
ENERGY CONSERVATION PPT by ee-63Dinesh Kumar
 
Energy conservation.pdf
Energy conservation.pdfEnergy conservation.pdf
Energy conservation.pdfssuser65cc68
 
ICTs to Reduce Energy Consumption and GHG Emissions.ppt
ICTs to Reduce Energy Consumption and GHG Emissions.pptICTs to Reduce Energy Consumption and GHG Emissions.ppt
ICTs to Reduce Energy Consumption and GHG Emissions.pptssuseradc0be1
 
Energy conservation in industry
Energy conservation in industryEnergy conservation in industry
Energy conservation in industrySameer Kumar Rout
 
Ensuring Maximum Operational Performance in Cement Plant
Ensuring Maximum Operational Performance in Cement PlantEnsuring Maximum Operational Performance in Cement Plant
Ensuring Maximum Operational Performance in Cement PlantFouad Ghoneim, PMP®, SSYB®
 
Bowman Power Innovation Showcase - Cleantech Forum Asia 19
Bowman Power Innovation Showcase - Cleantech Forum Asia 19Bowman Power Innovation Showcase - Cleantech Forum Asia 19
Bowman Power Innovation Showcase - Cleantech Forum Asia 19Bowman Power
 
Indian energy efficiency scene..a macro perspective.
Indian energy efficiency scene..a macro perspective.Indian energy efficiency scene..a macro perspective.
Indian energy efficiency scene..a macro perspective.D.Pawan Kumar
 

Semelhante a 001 conservation-Energy Audit -Methods (20)

Energy Management System in Forging industries2
Energy Management System in Forging industries2Energy Management System in Forging industries2
Energy Management System in Forging industries2
 
Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...
Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...
Eng. Demiss Alemu - Energy Efficiency Improvement and GHG Emission Reduction ...
 
EnMS Article, World Cement
EnMS Article, World CementEnMS Article, World Cement
EnMS Article, World Cement
 
Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...
Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...
Reducing energy intensity of the Indian economy, Saurabh Diddi, Bureau of Ene...
 
Energy Conservation By Mehfooz Qazi
Energy Conservation By Mehfooz QaziEnergy Conservation By Mehfooz Qazi
Energy Conservation By Mehfooz Qazi
 
Energy Efficiency for Malaysia-the way forward
Energy Efficiency for Malaysia-the way forwardEnergy Efficiency for Malaysia-the way forward
Energy Efficiency for Malaysia-the way forward
 
Energy efficiency in the tennessee valley
Energy efficiency in the tennessee valleyEnergy efficiency in the tennessee valley
Energy efficiency in the tennessee valley
 
Modelling global macroeconomic impacts of a carbon constrained energy system ...
Modelling global macroeconomic impacts of a carbon constrained energy system ...Modelling global macroeconomic impacts of a carbon constrained energy system ...
Modelling global macroeconomic impacts of a carbon constrained energy system ...
 
Energy Efficiency: A kenya power perspective
Energy Efficiency: A kenya power perspectiveEnergy Efficiency: A kenya power perspective
Energy Efficiency: A kenya power perspective
 
ENERGY CONSERVATION PPT by ee-63
ENERGY CONSERVATION PPT by ee-63ENERGY CONSERVATION PPT by ee-63
ENERGY CONSERVATION PPT by ee-63
 
Energy conservation.pdf
Energy conservation.pdfEnergy conservation.pdf
Energy conservation.pdf
 
ICTs to Reduce Energy Consumption and GHG Emissions.ppt
ICTs to Reduce Energy Consumption and GHG Emissions.pptICTs to Reduce Energy Consumption and GHG Emissions.ppt
ICTs to Reduce Energy Consumption and GHG Emissions.ppt
 
renewablle energy.ppt
renewablle energy.pptrenewablle energy.ppt
renewablle energy.ppt
 
Energy conservation in industry
Energy conservation in industryEnergy conservation in industry
Energy conservation in industry
 
Ensuring Maximum Operational Performance in Cement Plant
Ensuring Maximum Operational Performance in Cement PlantEnsuring Maximum Operational Performance in Cement Plant
Ensuring Maximum Operational Performance in Cement Plant
 
Is12615 2011
Is12615 2011Is12615 2011
Is12615 2011
 
Bowman Power Innovation Showcase - Cleantech Forum Asia 19
Bowman Power Innovation Showcase - Cleantech Forum Asia 19Bowman Power Innovation Showcase - Cleantech Forum Asia 19
Bowman Power Innovation Showcase - Cleantech Forum Asia 19
 
Indian energy efficiency scene..a macro perspective.
Indian energy efficiency scene..a macro perspective.Indian energy efficiency scene..a macro perspective.
Indian energy efficiency scene..a macro perspective.
 
Ee opportunities
Ee opportunities Ee opportunities
Ee opportunities
 
PCRASR
PCRASRPCRASR
PCRASR
 

Último

social pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajansocial pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajanpragatimahajan3
 
Arihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdfArihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdfchloefrazer622
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxheathfieldcps1
 
General AI for Medical Educators April 2024
General AI for Medical Educators April 2024General AI for Medical Educators April 2024
General AI for Medical Educators April 2024Janet Corral
 
Disha NEET Physics Guide for classes 11 and 12.pdf
Disha NEET Physics Guide for classes 11 and 12.pdfDisha NEET Physics Guide for classes 11 and 12.pdf
Disha NEET Physics Guide for classes 11 and 12.pdfchloefrazer622
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Sapana Sha
 
9548086042 for call girls in Indira Nagar with room service
9548086042  for call girls in Indira Nagar  with room service9548086042  for call girls in Indira Nagar  with room service
9548086042 for call girls in Indira Nagar with room servicediscovermytutordmt
 
Class 11th Physics NEET formula sheet pdf
Class 11th Physics NEET formula sheet pdfClass 11th Physics NEET formula sheet pdf
Class 11th Physics NEET formula sheet pdfAyushMahapatra5
 
Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfciinovamais
 
Unit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptxUnit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptxVishalSingh1417
 
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...Sapna Thakur
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactdawncurless
 
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhikauryashika82
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdfQucHHunhnh
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfagholdier
 
1029 - Danh muc Sach Giao Khoa 10 . pdf
1029 -  Danh muc Sach Giao Khoa 10 . pdf1029 -  Danh muc Sach Giao Khoa 10 . pdf
1029 - Danh muc Sach Giao Khoa 10 . pdfQucHHunhnh
 
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptxSOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptxiammrhaywood
 
fourth grading exam for kindergarten in writing
fourth grading exam for kindergarten in writingfourth grading exam for kindergarten in writing
fourth grading exam for kindergarten in writingTeacherCyreneCayanan
 

Último (20)

social pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajansocial pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajan
 
Arihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdfArihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdf
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptx
 
General AI for Medical Educators April 2024
General AI for Medical Educators April 2024General AI for Medical Educators April 2024
General AI for Medical Educators April 2024
 
Disha NEET Physics Guide for classes 11 and 12.pdf
Disha NEET Physics Guide for classes 11 and 12.pdfDisha NEET Physics Guide for classes 11 and 12.pdf
Disha NEET Physics Guide for classes 11 and 12.pdf
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
 
9548086042 for call girls in Indira Nagar with room service
9548086042  for call girls in Indira Nagar  with room service9548086042  for call girls in Indira Nagar  with room service
9548086042 for call girls in Indira Nagar with room service
 
Class 11th Physics NEET formula sheet pdf
Class 11th Physics NEET formula sheet pdfClass 11th Physics NEET formula sheet pdf
Class 11th Physics NEET formula sheet pdf
 
Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdf
 
Unit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptxUnit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptx
 
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impact
 
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
 
Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdf
 
1029 - Danh muc Sach Giao Khoa 10 . pdf
1029 -  Danh muc Sach Giao Khoa 10 . pdf1029 -  Danh muc Sach Giao Khoa 10 . pdf
1029 - Danh muc Sach Giao Khoa 10 . pdf
 
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptxSOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
 
fourth grading exam for kindergarten in writing
fourth grading exam for kindergarten in writingfourth grading exam for kindergarten in writing
fourth grading exam for kindergarten in writing
 
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptxINDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
 

001 conservation-Energy Audit -Methods

  • 1. ANIL PALAMWAR RETIRED CHIEF ENGINEER, KHAPERKHEDA TPS. DIRECTOR (OPERATION) MAHAVITARAN • NEED FOR ENERGY AUDIT. • AUDIT PROCEEDURES • ENERGY AUDIT – • MACRO LEVEL • AND • MICRO LEVEL. 1
  • 2. Energy Audit ????? • We know Financial Audit. • Audit of Public Enterprises. • Balancing of Income & Expenses. • Whether rules are followed ? • E.A. is slightly different. • Energy Audit deals with - • Losses – Efficiency – Conservation • Promotes :- Economy, competitiveness & Environment. 2
  • 3. ENERGY CONSERVATION ENERGY IS THE CAPACITY TO DO WORK. ENERGY IS AVAILABLE FROM WIND-WATER-SUN -FOSSIL FUEL MOSTLY WE WORK WITH ELECTRICAL OR THERMAL ENERGY. Why Conserve? 1. - RESOURCES ARE LIMITED. 2.-COST REDUCTION TO REMAIN VIABLE IN COMPETITION. 3.- Environment - Global warming - GHGs 3
  • 4. EFFICIENCY OF RANKINE CYCLE IS LIMITED TO 35-40 %. C.C.G.T. PLANTS GO UP TO 52-55 %.Efficiency. [Combined Cycle Gas Turbines] SO IF HEAT IS USED DIRECTLY, [WITHOUT CONVERTING TO ELECTRICITY], CYCLE EFFICIENCY WILL INCREASE. CO-GENERATION ADOPTS THIS PRINCIPLE. Industrial units must explore the possibility of use of waste heat. Where ever a furnace is used, lot of waste heat is available for use in some way or other. IN SIMPLE WORDS – WHEN 100 M.T. OF FUEL IS USED, ONLY 40 MT IS USED TO PRODUCE ELECTRICITY, HEAT VALUE OF REMAINING 60 M.T. GOES UNUSED TO THE ATMOSPHERE. 4
  • 5. ALSO- CONSIDER THE SYSTEM LOSSES- Transmission Three Transformers-220/33; 33/11 ; 11/0.415 KV--- Efficiency=0.99 x0.99 x 0.99 =0.97 or 97% Transmission Efficiency= 94 %, Distribution Efficiency=85% Motor Efficiency=80 % Pump Efficiency = 80% Total system Efficiency= 0.97x0.94x0.85x0.80x0.80=0.4960 or 49.60% 5
  • 6. It means that for every unit consumed, two units are generated and sent from a power station. Conservation is therefore necessary. Waste must be avoided . Cost is the most powerful motivating factor for conservation. Maharashtra State needs approximately 300 MU of electricity per day. (Average) Only about 150 MU are really utilized. Efficiency is of utmost importance. Every process needs thorough check to identify losses. 6
  • 7. Transformers- Losses within limits-e.g. MSEDCL Motors-Pumps-Fans- e.g. Feed Pump and P.A. Fans at KPKD TPS. Procurement-Installation-O&M - All these affect performance-and losses. Ducting and its aerodynamics- Eddy formation Selection of correct pipe dia and cleanliness of pipes. Air conditioning- use of vapour cycles where waste heat is used. Properly set thermostats. Maximum use of daylight and Natural ventilation. 7
  • 8. ENERGY AUDIT FRIENDS & ENEMIES 8 NEGATIVE FORCES GOAL -TO REDUCE ENERGY CONSUMPTION POSITIVE FORCES HIGH PRICEOF ENERGY EFFICIENTTECHNOLOGY TAX ON ENERGY TOP MANAGEMENTSUPPORT ENERGY INTENSIVE INDUSTRY NO CORPORATE ENERGY POLICY NO AWARENESS IN THE COMPANY INSUFFICIENTSKILLS & KNOWLEDGE COMPETING CORPORATE POLICIES INSUFFICIENT FUNDS
  • 9. FOUR PILLARS OF ENERGY MANAGEMENT 9 TECHNICAL ABILITY MONITORING SYSTEM STRATEGY PLAN TOP MANAGEMENT SUPPORT ENERGY MANAGEMENT
  • 10. MATERIAL BALANCE 10 SOLID WASTE FOR STORAGE & DISPOSAL WATER / AIR PROCESS OPERATIONS REUSABLE WASTE GASEOUS EMISSION PRODUCT BYE PRODUCT WASTE WATER LIQUID WASTE FOR STORAGE & RAW MATERIALS CHEMICALS
  • 11. ENERGY BALANCE 11 ENERGY IN HOT RESIDUE ENERGY IN CONDENSATE COMPRESSED AIR ENERGY IN COOLING WATERENERGY IN RAW MATERIAL ENERGY IN VAPOUR ELECTRICITY STEAM RADIATION LOSS PROCESS OPERATIONSCOOLING WATER ENERGY IN HOT PRODUCTS
  • 12. 12
  • 13. 13
  • 14. 14
  • 15. NON Renewable Energy Sources 15
  • 17. 17 It took more than 3 million years to convert to Fossil Fuels.
  • 18. INTRODUCTIONINTRODUCTION Conventional source of energy such as coal, oil and gas are scarce and exhaustible. Energy prices will rise in the long run to reflect their relative scarcity and high cost of exploration and extraction. Hence, all attempts must be made expeditiously to ensure the optimal use of the available resources to manage the viability and availability of energy. 18
  • 19. INTRODUCTION (contd.)INTRODUCTION (contd.)  Government of India enacted the Energy Conservation Act – 2001.  For efficient use of energy and its conservation to mitigate the gap between demand and supply and to promote economic competitiveness.  The Act provides for  Institutionalizing and strengthening delivery mechanisms for energy efficiency services in the country and  Provides the much-needed coordination between the various organizations and stakeholders,  Within the Government and in the private sector. 19
  • 20. Enacted in October 2001Enacted in October 2001 Become effective from 1st March 2002Become effective from 1st March 2002 Bureau of Energy Efficiency (BEE) operationalizedBureau of Energy Efficiency (BEE) operationalized from 1from 1stst March 2002.March 2002. MISSION OF BEEMISSION OF BEE Develop policy and strategies with aDevelop policy and strategies with a thrust on self regulation and marketthrust on self regulation and market principles, within the overall framework of theprinciples, within the overall framework of the EC Act with the primary objective of reducingEC Act with the primary objective of reducing energy intensity of the Indian economy.energy intensity of the Indian economy. 20
  • 21. 1. DESIGNATED CONSUMERS1. DESIGNATED CONSUMERS ( Energy Intensive Industries and other Establishments)( Energy Intensive Industries and other Establishments) A programme to initially focus on energy policyA programme to initially focus on energy policy issues of energy efficiency improvement,issues of energy efficiency improvement,  in organized sectors such asin organized sectors such as  energy intensive industries and.energy intensive industries and.  commercial sector,commercial sector,  through establishment of energy managementthrough establishment of energy management system,system,  capacity building of energy professionals,capacity building of energy professionals, implementation of energy audits,implementation of energy audits, establishments of specific energy consumption normsestablishments of specific energy consumption norms  support to consumers on providing information onsupport to consumers on providing information on authentic energy dataauthentic energy data 21
  • 22. Designated Industries Schedule - Responsibilities  Schedule to EC Act provides list of 15 energySchedule to EC Act provides list of 15 energy intensive industries and other establishments to beintensive industries and other establishments to be notified as designated consumers (DC).notified as designated consumers (DC).  Designated Consumers to -Designated Consumers to - Appoint or designate energy managersAppoint or designate energy managers Get energy audits conducted by accreditedGet energy audits conducted by accredited energy auditorsenergy auditors Implement techno-economic viableImplement techno-economic viable recommendationsrecommendations Comply with norms of specific energyComply with norms of specific energy consumption fixedconsumption fixed Submit report on steps takenSubmit report on steps taken 22
  • 23. 1) Designated Consumers Thermal Power Stations- 30,000 Million tonne of oil equivalent (MTOE) per year and above 2) Fertilizer- 30,000 MTOE per year and above 3) Cement- 30,000 MTOE per year and above 4) Iron & Steel- 30,000 MTOE per year and above 5) Chlor-Alkali- 12,000MTOE per year and above 6) Alluminium- 7,500 MTOE per year and above 7) Railways- One traction substation in each Zonal Railway , Production units and Workshops of Indian Railways having total annual energy consumption of 30,000 MTOE or more under Ministry of Railways 8) Textile-3,000 MTOE per year and above 9) Pulp & Paper-30,000 MTOE per year and above 23
  • 24. WHY ENERGY EFFICIENCY IS IMPORTANT ?WHY ENERGY EFFICIENCY IS IMPORTANT ? • We do something to enjoy, save money & resources and finally because it is the LAW. • So Energy Audit – Because, • Depleting fossil fuel-Resources are scarce • Optimum plant utilization-Competitiveness. • Global warming-Carbon Credit • Designated consumer-E.A. is Mandatory. • Generate more energy with same quantity of fuel 24
  • 25. PERIOD STEAM PRESSURE& TEMPERATURE UNIT SIZE (MW) TURBINE Heat Rate (Kcal/kWh) Unit Heat Rate (Kcal/kWh)/ Efficiency 1951-60 60 kg/cm2 , 482o C 30 – 57.5 2470 1961-75 70 kg/cm2 , 496o C to 90 ata 538o C 60 – 100 2370 1961-75 130 ata 535/535o C 110 – 120 2170 – 2060 2552-2423 1977-82 130 ata 535/535o C 210 (Russian) 2060 2423/ 35.4% 1983+ 150 ata 535/535o C 210 (Siemens) 2024 2335 36.8% 1984+ 170 ata 535/535o C 500 1950 (TDBFP) 2294 37.4% 1990+ 150 ata 535/535o C 170 ata 538/538 o C 210/ 250 250/ 500 1950 (MDBFP) 1950 (TDBFP) 2294 2294 THIS CHART SHOWS THE GRADUAL IMPROVEMENT IN HEAT RATE TO ACHIEVE ECONOMY 25
  • 26. EFFICIENCY IMPROVEMENT CAN GIVE YOU For an average increase of 1 % in the Efficiency would result in:-  Coal savings of approx. 11 million tons per annum worth Rs.13,000 Million  CO2 reduction about 13.5 million tons per annum  Lower generation cost per kWh- as more efficient the unit works, the more economical it is  1% increase in efficiency for 210 Mw unit with heat rate 2335 kcal/kwh means heat rate improvement to 2275 kcal/kwh 26
  • 27. MAJOR CAUSE OF INEFFICENCY IN POWER PLANTMAJOR CAUSE OF INEFFICENCY IN POWER PLANT • High Flue gas exit Temp • Excessive amount of excess air(O2)(Increases dry flue gas loss) • Poor Mill/Burners performance causing high unburnt carbon in fly and bottom ash. • Poor insulation. • Poor house Keeping. • Poor instrumentation and automation 27
  • 28. MAJOR CAUSE OF INEFFICENCY INMAJOR CAUSE OF INEFFICENCY IN POWER PLANTPOWER PLANT (Cont…) • Not running the units on design parameter • Heaters not in service or poor performance of regenerative system • Poor condenser vacuum • Excessive DM water consumption- passing and leakages • Use of Reheat spray to control Reheat Temperature • Poor Cylinder Efficiency of turbine 28
  • 29. CONTROLLABLE PLANT PARAMETERS • M.S. & R.H. Steam Temperatures • M.S. Steam Pressure • Condenser Vacuum • Final Feed Water Temperature • DP Across Feed Regulation Station • Auxiliary Power Consumption • Make Up Water Consumption 29
  • 30. HOW TO ACHIEVE ENERGYHOW TO ACHIEVE ENERGY EFFICIENCY ?EFFICIENCY ? • Adopt state of the art technologies • Adopt cutting edge technologies • Review & Re-engineering of the existing systems • Bench Marking • Energy Auditing 30
  • 31. CAN WE IMPROVECAN WE IMPROVE EFFICIENCY?EFFICIENCY?  Yes, provided we shed the myths and believe in applying result oriented efforts  Workout to identify & quantify the cost of hidden losses  Bring in requisite operational behavioral change 31
  • 32. SOME OF THE MYTHS  High PLF & availability translates into Optimum Efficiency  Heat rate is the responsibility of Efficiency Management Group at Stations  Equipment maintenance to be taken-up based on periodic overhaul schedule  Boiler performance degradations has no relation to Turbine Cycle performance 32
  • 33. Some of the Myths contd… • Design heat rate is the best achievable heat rate • Efficiency tests are the same as performance guarantee test • Heat rate improvement requires large investment. • Results follow immediately after testing is completed • Heat rate is the responsibility of Energy & Efficiency Management Group (EEMG) at Stations • Station instruments are accurate for monitoring heat rate parameters 33
  • 34. Some of the Myths contd… “Design” is not the best achievable performance • Predicted performance based on Turbine Heat Balance Diagrams and Boiler Efficiency at different loads • ‘Design’ is based on specific ambient conditions that vary throughout the year • Actual initial performance could be different from design or changes might have been made to plant • Current performance to be compared to an achievable ‘expected’ value to establish efficiency gaps 34
  • 35. SYNERGIZE OPERATION OF UNIT Need to clearly understand the relation between performance & fuel, operation and design parameters Operational behavior and performance Impacts of operating efficiency of Boiler, Turbine and their auxiliaries on Net Unit Heat Rate Maximum Achievable Load, Maintenance & Availability 35
  • 36. SOME CRITICAL FACTORS AFFECTING BOILER PERFORMANCE • Fuel:- Heating Value, Moisture Contents, Ash Composition, Ash Contents,& Volatile Matter. • Operational Parameter:- Level of Excess Air, & operating Condition of Burner Tilt Mechanism. • Design:- Heating input per plan area, Height of Boiler, Platens & pendants heat transfer Surfaces, Burner & wind Box design. 36
  • 37. BEHAVIOURAL IMPACTS • Low heat value results in over firing of fuel causing more heat availability for super heater and re-heater thus more attempration spray requirement. Hence increase in THR, overloading of ash handling system, fans and increased soot blowing • Moisture content increase causes increase in heat transfer to S.H, and R.H. Hence again increase in attempration spray and THR (Turbine Heat Rate) • Ash composition and contents increases damage to pressure parts surfaces because of melting behavior of low fusion ash temperature of blended coal in particular • In consistency in fired fuel characteristics results in variation in excess air requirement thereby increasing stack loss and hence boiler efficiency reduction, overloading of ID Fan and ultimately unit load limitation • High heat value causes excessive radiant heat transfer to water walls thereby leaving lesser heat for super heater and re-heater • . 37
  • 38. Normally excess air ranges from 15% to 30% of stoichiometric air. • High O2 % and presence of CO at ID Fan outlet are indicator of air in leakages and improper combustion in furnace • Poorly effective damper control also is the cause of higher SEC of fans both primary and secondary • The quality and purity of feed water and make up water is also required to be maintained in a meticulous way by limiting blow down losses to nearly 1% and by checking the passing and leakages of valves. However, maximum 3% of flow can be taken as make up for these causes including soot blowing requirements • Soot blowing is dependent on ash contents and is unit specific. Intelligently devised soot blowing can result in saving the fuel BEHAVIOURAL IMPACTS 38
  • 39. • Cascading effects on efficiency, loading and availability because of following systems and equipments performance also needed to be looked into. The systems are:- Fuel receiving, preparation and handling systems. Pulverizing system Air Heater Fans Electrostatic Precipitator Fly ash handling system Bottom ash handling system Waste disposal system BEHAVIOURAL IMPACTS 39
  • 40. PERFORMANCE IMPACTS ON STEAM CYCLE , UNIT HEAT RATE & OUTPUT • Various design & operating parameters of a unit are responsible for its cycle performance, heat rate,& out put 40
  • 41. CRITICAL FACTORS AFFECTING CYCLE PERFORMANCE 1. Re-heater & its system pressure drop 2. Extraction line pressure drop 3. Make up 4. Turbine exhaust pressure 5. Air preheat 6. Condensate sub-cooling 7. S/H & R/H spray flows 8. Wet Bulb Temp 9. Top Heaters out of service 10. H.P. heater drain pump 11. Type of BFP drives & method of flow control 41
  • 42. RH & ITS SYSTEM PRESSURE DROP…. • Every one 1% decrease in drop can improve THR and output by 0.1% & 0.3% respectively • Normally designed for pressure drop equivalent to 10% of HP exhaust pressure • Causes are Feed Heater abnormalities R/H safety valve passing 42
  • 43. EXTRACTION LINE PRESSURE DROP… • Permissible pressure drop between stage pressure & Shell pressure is maximum 6% • For every 2% increase in this pressure drop, THR would be poorer by 0.09% 43
  • 44. CYCLE MAKE-UP…. • Acceptable value of make up water is 3% to offset cycle water losses • For every 1% increase in make up 0.4% increase in THR & 0.2% reduction on output is there 44
  • 45. EXHAUST PRESSURE… • Increase & decrease in exhaust pressure do affect the THR. • Though no valid thumb rule has been devised so far, however last stage blade design & exhaust area of turbine do affect the impact of changing exhaust pressure. 45
  • 46. AIR PRE-HEAT…. • Air preheating of combustion air before entry to regenerative air heater is done with either steam coil air pre - heater or hot water pre heating coil to maintain Average Cold End Temperature (ACET) to escape dew point temperature complications • Condensate retrieval is necessary to avoid deterioration to THR depending upon unit load and combustion pre heating duty 46
  • 47. CONDENSATE SUB-COOLING… • For 30% total flow and 2.5 deg C sub- cooling ,an increase of 0.001% in THR can be there for every subsequent 10% increase in flow 47
  • 48. R.H & S.H. SPRAY FLOW… • Spray water whether drawn from BFP or after the final heater, it is always less the generative and less productive as well • Every 1% spray flow, correction need to be done in THR & load computed from the curves supplied with the machine 48
  • 49. TOP HEATER OUT OF SERVICE…. • Extraction steam flow meant for top heater passes through the turbine thereby increasing the output. • But at the same time final feed water temp is lowered resulting in poor Total Heat Return. • More fuel must be used in the boiler to add the sensible heat (Not imparted by the feed heater) • The % loss increases from lowest stage (.5 to .6 ) to highest stage (1.2 to 1.5%) • Roughly each Deg C in TTD will result in a loss of 0.25% efficiency. 49
  • 50. PERFORMANCE MONITORING • Analyze the poor efficiency areas from previous record • Go down to specific system and then to component • Carry out performance/diagnostic study as suggested in the Auditing Manual & operating manual • Devise a unit specific efficiency control sheet for few terminal conditions (Actual vs Design) • Monitor once per shift to know the operating efficiency and check any deterioration 50
  • 51. Coal Handling Plant • Coal Crushers- • If significant quantity of coal >20 mm size is observed on down side of crusher then it may led to substantial decrease in mill performance. • Identification of combination of various least power consuming equipment and recommending merit order operation. • Use of natural daylight through conveyor galleries and use of fire resistant translucent sheet. 51
  • 52. Soft Starters- V.F.D. • Explore Installation of power saver device in major LT motors. (Conveyor belt etc.): • Major HT /LT motors i.e. conveyors, crushers etc. are often partially loaded & also there are frequent starts /stops. • Explore the possibility of providing power saver devices (soft starters) in major motors. 52
  • 53. Power Factor of Motors. • Power factor correction possibility: • Induction motors may have vey low power factor, leading to lower overall efficiency. • Capacitors connected in parallel with the motor are used to improve the power factor. • The PF correction reduces KVA demand, • reduced I2 R losses in cable upstream of capacitor, • reduced voltage drop in cables (leading to improved voltage regulation), • and an increase in the overall efficiency of the plant electrical system. 53
  • 54. Chemicals for Dust Suppression • Explore the possibility of using chemicals for reduced water spray: • Mixing of chemical compounds in water provides much better atomization of water spray, by reduction in surface tension of water. • Thus for the given application of dust suppression, less quantity of water is sprayed which also results into less wastage of latent heat in the steam generator. 54
  • 55. Use of Bull Dozers ? • Maximum Mechanical Handling: • Minimum Bulldozing: Receipt, unloading, stacking and reclaiming and the selection of machinery should be such that all the handling operations are accomplished without the use of semi mechanized means like bulldozers which are more energy intensive equipment. • When coal is stocked in yard for more than incubation period (duration between coal mined and getting self ignited), special precautions like compacting, water spraying must be taken.   55
  • 56. Bunkering Frequency • Reduced Number of Fillings: • Live storage capacity of raw coal bunkers and the filling pattern of bunkers is so planned that, • 24 hours coal requirement of the generating units is met by not more than two fillings per day. • This will eliminate frequent starting and stopping of the CHP system. 56
  • 58. Energy audit of Boiler • Coal quality - composition and calorific value • Coal milling aspects • Combustion and excess air • Re-heaters • Heat recovery units – Economisers, air preheaters, etc, • Insulation aspects • Boiler blow down aspects- Water Chemistry • Soot blowing aspects- Effectiveness • Operation and maintenance features which affect the energy efficiency • Condition & status of boiler and their internals • Feed water system aspects • Air and flue gas system aspects 58
  • 59. STEPS  IN  ENERGY AUDIT  • Data collection • Observations and Analysis • Exploration for energy conservation measures • Report preparation – DATA COLLECTION • The first step in energy audit of boiler is to collect the design / PG test parameters pertaining to boiler, economiser, air preheaters, coal and coal milling, soot blowing and other key associated equipment. 59
  • 60. Particulars Unit Details at Normal cont. rating, NCR Make BHEL Type Water tube single drum Capacity tph 627.32 Main Steam pressure kg/ cm2 155 Main Steam temperature 0C 540 Boiler efficiency % 87.16 Super heater outlet flow tph 627.32 Reheater outlet flow tph 565.6 Coal Calorific value –GCV kcal/ kg 4350 Coal consumption tph 106.2 Total combustion air tph 822 LTSH outlet temperature 0C 420 Reheater outlet temperature 0C 540 Water- economizer inlet temperature 0C 241 Water- economizer outlet temperature 0C 280 Oxygen content at Economizer outlet % 4.23 60
  • 61. Unit Design NCR Actual Make Type Year of Installation Main Steam Pressure kg/ cm2 Main Steam Temperature oC Main Steam Flow tph Steam pressure at LTSH out let kg/ cm2 Steam temperature at reheater inlet oC Steam temperature at reheater outlet oC Steam pressure at reheater inlet kg/ cm2 Steam pressure at reheater outlet kg/ cm2 Steam temperature at LTSH out oC Saturated steam temperature in drum oC Super heater platen outlet temperature oC Pressure drop in reheater Kg/ cm2 Super heater spray tph Reheater Spray tph Design ambient temperature oC Coal consumption tph DESIGN DATA 61
  • 62. ECONOMISER DATA Unit Design Actual Feed water pressure at the inlet kg/ cm2 Feed water pressure at the outlet kg/ cm2 Feed water flow Tph Feed water temperature at the inlet oC Feed water temperature at the out let oC Oxygen content in flue gas before economizer % Excess air % in flue gas before economizer % Exhaust gas inlet temperature oC Exhaust gas outlet temperature oC Exhaust gas quantity Tph 62
  • 63. AIR PRE HEATER DATA Unit Design Actual Air quantity at APH outlet (primary) Tph Tempering air Tph Air heater outlet (secondary) Tph Total combustion air Tph Air temperature at fan outlet oC Air outlet temperature of APH – primary oC Air outlet temperature of APH– secondary oC Oxygen content in flue gas before APH % Oxygen content in flue gas after APH % Excess air % in flue gas before APH % Flue gas inlet temperature oC Flue gas outlet temperature oC Flue gas quantity Tph Others 63
  • 64. EXHAUST GAS TEMPERATURE PROFILE Unit Design Actual Temperatures at different location oC Super heater platen outlet oC RH front inlet oC RH rear inlet oC SH final inlet oC LTSH inlet oC Economizer inlet oC APH inlet oC APH outlet oC ID Fan inlet oC ID fan outlet oC 64
  • 65. BOILER HEAT BALANCE Unit Design Ambient temperature oC Excess air % Dry flue gas loss % Hydrogen loss % Moisture in fuel loss % Moisture in air loss % Unburnt combustible loss % Radiation loss % Un accounted loss % Gross boiler efficiency on HHV % Guaranteed efficiency % 65
  • 66. Feed water & Boiler water limits Unit Feed water Remarks pH at 25oC Oxygen – maximum ppm Total iron- maximum ppm Total silica – maximum ppm Conductivity at 25oC Microsiemens Hydrazine residual ppm Total solids – maximum ppb Chlorides ppm Copper – maximum ppm Permanganite consumption ppm 66
  • 67. MILLS AND BURNERS PERFORMANCE Unit Requirement at MCR Actual Remarks No of coal burners No PA flow tph No of mills in operation No Mill loading % Air temperature at mill inlet after tempering oC Air – fuel mixture temperature after leaving mills oC Total coal fired tph Air Coal ratio 67
  • 68. Mill specifications: • Type of mill : • Make : • Capacity : __________tph at coal ________grind • Fineness : ___________% through ________mesh • Motor rating :____________kW • Motor voltage :________ V • No of mills :__________ • Running /Standby :_________/________ 68
  • 69. COAL DATA • Design coal parameter • Moisture :_____% • Ash :_____% • Volatile matter :_____% • Fixed carbon :______% • HGI :_____% 69
  • 70. SOOT BLOWERS Type number Soot blowers for furnace Soot blowers for super heaters Soot blowers for reheaters Soot blowers for air preheaters Medium of blow Steam pressure before reduction Steam pressure after reduction Steam consumption 70
  • 71. Instruments For Energy Audit • The following instruments are required for conducting the boiler energy audit. • Power Analyser: Used for measuring electrical parameters such as kW, kVA, pf, V, A and Hz • Temperature Indicator & Probe • Stroboscope: To measure the speed of the driven equipment and motor • Sling hygrometer or digital hygrometer • Anemometer • Available On line instruments at the site ( Calibrated ) • Digital Manometer of suitable range and appropriate probes for measurement of pressure head and velocity head. • 71
  • 72. • Additional pressure gauges with appropriate range of measurement and calibrated before audit. • Flue gas analysers / Orsat apparatus • Infrared pyrometers • Pressure gauges • Steam trap tester / Ultra sonic leak detectors • Instrument to measure coal velocity in coal feed pipe 72
  • 73. MEASUREMENTS & OBSERVATIONS • Average GCV of coal during audit period • Coal analysis – ultimate and proximate • Coal consumption details • Performance parameters of coal mills • Steam parameters of main steam, reheat, super heater, LTSH (flow, pressure and temperature) • Air – flow, temperature, pressures 73
  • 74. MEASUREMENTS & OBSERVATIONS • Flue gas – Flow, temperature and pressure • Flue gas analysis • Ambient temperature • Boiler loading • Motor electrical parameters (kW, kVA, Pf, A, V, Hz, THD) • Surface temperatures of insulation and boiler surfaces • Un-burnt coal (in fly ash and bottom ash) 74
  • 75. 75
  • 76. 76
  • 77. 77
  • 78. 78
  • 79. 79
  • 80. 80
  • 81. 81
  • 82. 82
  • 83. 83
  • 84. 84
  • 85. 85
  • 86. 86
  • 87. 87
  • 88. 88
  • 89. 89
  • 90. 90
  • 91. 91
  • 92. 92
  • 93. 93
  • 94. 94
  • 95. 95
  • 96. 96
  • 97. 97