Considering that 75% of the information used by physicians to make a diagnosis is derived from laboratory test results, it is vital that
laboratories perform regular checks to ensure the results released are accurate and reliable.
The objective of Quality Control is to detect laboratory errors and ultimately, prevent the release of inaccurate test results which
could lead to misdiagnosis, inappropriate treatment or treatment delays, all of which could be potentially life threatening for the
patient. Quality Control will also decrease the need for repeat tests, directly reducing costs as a result.
A good Quality Control programme should incorporate both Internal Quality Control (IQC)
and External Quality Assessment (EQA).
The use of IQC alone is not a sufficient measure of laboratory performance. Participation in an EQA scheme is also required to
ensure confidence in patient results.
While IQC will effectively monitor the reproducibility or precision of laboratory testing, it doesn’t enable laboratories to monitor
bias or accuracy. Accuracy refers to how close the result generated by the laboratory is to the true value of the sample. In order
to effectively monitor accuracy, laboratories must participate in an EQA programme.
Best Laboratory Prctices
‘The laboratory shall participate in interlaboratory comparisons such as those organised by
external quality assessment programmes. Laboratory management shall monitor the results
of external quality assessment and participate in the implementation of corrective actions
when performance criteria are not fulfilled’
ISO 15189:2012 Medical Laboratories: Requirements for quality and competence
Internal
Quality
Control
External
Quality
Assessment
Total Quality Assurance
EQA: an Essential Tool for Laboratory Quality
Implementation of an EQA scheme,although appearing to represent additional costs to the laboratory’s budget,will in the long term
decrease expenditure, increase productivity and, most importantly, improve performance and minimise patient risk.
Benefits of EQA
EQA – More than just Accreditation
• Provides management with an holistic view of test system performance that IQC alone cannot provide
• Identify potential equipment or reagent faults as well as staff training requirements and issues with staff competency
• Reduce the cost and time associated with expensive repeat tests
• Compare performance with other analytical methods on the market
• Initiate corrective action and evaluate the effectiveness of corrective actions
• Provides an independent assessment of laboratory accuracy for added confidence in patient test results
What Medical Professionals Say About EQA
The following real life testimonials show how EQA has helped laboratories in Africa to improve quality and performance.
“EQA has proved to be of huge benefit to our laboratory. This is mainly because of the narrow SD which ensures
that only accurate results are acceptable. EQA has been an eye opener to the shortfalls of our lab. We expect our
performance to improve and subsequently our reliability to clinicians.”
Tinei Makurumure, Quality Assurance Manager, Multi-Tech Diagnostics, Harare, Zimbabwe
“EQA has helped me and my team to identify problems associated with the calibration of my analyser. This has been
extremely beneficial in running my lab. It gives me confidence in my results and indicates where problems may arise.”
Mrs Anya, Laboratory Manager, Reddington Hospital, Lagos Nigeria
“EQA has improved our laboratory performance and increased our confidence. A good EQA scheme has the potential
to offer a wide range of parameters, covering a broad spectrum, rapid turnaround of results and user-friendly reports.
It should provide Multi – Instrument reports, allowing a laboratory to compare accuracy between their instruments.”
Dr Veena Vyas, Head of Department (Pathology) The Aga Khan Hospital, Dar es Salaam, Tanzania
“The Nairobi hospital has been using EQA for more than two decades and throughout this period we have been happy
partners. EQA provides samples that cover our entire test panel including; blood gas, therapeutic drugs, immunoassay,
biochemistry, urinalysis & haematology. Frequent samples are most appropriate for our hospital enabling us to identify
non-conforming tests quickly. A good EQA scheme will provide a good reporting format to interpret results and enable
us to sustain our ISO 15189 accreditation.”
Dr Peter Kariuki, Deputy Manager of Laboratory Services, The Nairobi Hospital, Nairobi, Kenya
“Our laboratory is a hospital and clinical lab which seeks high technical quality to ensure reliable results. That is why we
enrolled for an EQA programme, aware that it provides valuable data and information which will ensure accurate results
for our customers, e.g., physicians, patients, health authorities and NGOs alike. EQA provides early warning to problems
in laboratory practices, allowing appropriate corrective action and continuous quality improvement.”
Mrs Maria Santo, Laboratory Manager, ICOR - Instituto do Coração Maputo, Mozambique
Real Life Case Studies Highlighting the Importance of Running Both IQC and EQA in a Laboratory
The following case studies highlight the importance of participating in a reputable EQA scheme in addition to daily IQC to ensure
laboratory quality and prevent the release of incorrect patient results, which could be potentially life threatening.
Detecting Concentration Issues
• Upon the review of their EQA report, Laboratory
‘A’ observed poor performance for Procalcitonin.
This was evident from the report’s Levey-Jennings chart,
which showed erratic dispersal of results.The
laboratory’s 1st Party IQC results however, remained
within acceptable ranges
• On examining the 1st
party IQC kit inserts it was
evident that the level 1 and level 3 were not at
clinically relevant levels and were not accurately
assessing the full range of the assay
Conclusion
A good EQA scheme provides samples covering a wider
spread of concentrations. Therefore, the EQA highlighted
the weaknesses of the range of the Procalcitonin assay
which the laboratory’s 1st Party IQC failed to detect.
Detecting Issues Hidden by Inadequate IQC
• Laboratory ‘B’ received EQA reports highlighting poor
EQA performance for Amylase but their IQC results
were within 2SD limits
•The laboratory contacted their EQA provider who
explained that although their IQC results were within
2SD, when the % deviation from the target is calculated
2SD was equal to 20%
•The acceptable limits of performance used by the EQA
scheme were much narrower, where 2SD was equal to
10% of the target value
•Therefore EQA proved to be a more stringent assessment
of the laboratory’s performance
Conclusion
In this example, participation in an EQA scheme
highlighted that the acceptable ranges provided by the QC
manufacturer were unrealistically wide, thus masking an
issue with the test system and ultimately resulting in the
laboratory falsely believing that its results were accurate.
Financial and Human Impact of Misdiagnosis
Avoidable repeat tests cost the
US $200 million every year
“Globally, best estimates put the
incidence of diagnostic error in
assessing patients in the range of
10% to 15%” (1)
Studies put the number of diagnostic
errors in Australia at 140,000 cases a
year, with 21,000 cases of serious harm
and between 2000 and 4000 deaths.
In 2008, medical errors cost the United States $19.5 billion.
About 87% or $17 billion were directly associated with additional
medical cost, including: ancillary services, prescription drug
services, and inpatient and outpatient care. (2)
1. http://theconversation.com/the-hidden-problem-of-medical-misdiagnosis-and-how-to-fix-it-14662
2. J Health Care Finance. 2012 fall; 39(1):39-50.The economics of health care quality and medical errors. Andel C1, Davidow
SL, Hollander M, Moreno DA
How does EQA Work?
EQA provides a means of periodically assessing laboratory performance in comparison with other laboratories using the same
method and instrument. Unlike IQC, EQA provides an effective method of monitoring a laboratory’s bias or accuracy through the
analysis of samples of unknown concentrations, otherwise known as ‘blind samples’. It also enables assessment of the complete
testing process including pre-analytical, analytical and post analytical phases.
After analysis,results are submitted to the scheme organiser for statistical evaluation. Laboratories will subsequently receive a report
comparing their performance to that of other participants in the programme.The diagram below illustrates how EQA works.
REGISTER
1
36.000 mg/dl
84.800 IU/ml
132.000 ng/ml
Certificate of Participation
Stephen Doherty
RIQAS Manager
Randox International Quality Assessment Scheme
Randox Laboratories Ltd., 55 Diamond Road, Crumlin, Co.Antrim, BT29 4QY, United Kingdom
PR-281APR15
<Name>
<Laboratory/Hospital>
abc
Place an order with your local
Randox representative. Register by
completing enrolment document and
submit at least 3 weeks before the
cycle starts
1
You will receive a
set of numbered
samples for the
cycle along with a
username/password
for RIQAS.Net *
2
Analyse the sample on the
recommended date
3
Enter and submit
results online
before the final
deadline
4 Receive report
within 72 hours and
review to assess
performance
5
Certificates will be awarded
at the end of the cycle
providing that more than half
of the results are returned
6
QUALITY CONTROL
* Provision can be made for labs without internet access
Levey-Jennings
Levey-Jennings charts are useful for
monitoring performance over time,
allowing instant identification of any
trends or bias. Ideally, results should fall
within 1SD (white region) either side of
the mean.
Participation in an EQA scheme alone will not automatically improve quality or performance. Perhaps the main value of participating
in an EQA scheme lies in the report generated by the scheme provider. Not only should reports be comprehensive, covering a
wide range of statistics and charts, it is also important that they are user-friendly and easy to interpret. The ability to understand an
EQA report will maximise the benefits of participating in an EQA scheme.
Understanding EQA Reports: the key to improving performance and quality
Histogram
Histograms provide a quick, visual
indication of how your laboratory
performs in relation to the instrument
mean, method mean and all method
mean.
% Deviation by concentration chart
Helps to quickly and easily identify any
concentration related bias within a test
system.
Target score chart
Unique to RIQAS, theTarget Score
chart provides a visual indication of
performance for the last 20 samples. A
target score of 50 or more is considered
acceptable.
When choosing an EQA scheme to complement your IQC there are several factors to be considered. The below checklist is
designed to help you choose, not only the most cost effective, but the highest quality EQA scheme.
Essential Criteria for Choosing an EQA Scheme
• Large number of participants increasing statistical
validity and ensuring availability of peer group data
for a wide range of analytical methods
• Accreditation to ISO/IEC 17043:2010
• Frequent analysis ensuring system errors are
identified as early as possible
• Rapid report turnaround allowing corrective
actions to be taken immediately with minimum risk
to patients
• Samples that cover the complete clinical range and
behave in the same manner as patient samples
• Ability to register multiple instruments
• Multi-analyte programmes allowing effective
consolidation
• User-friendly yet comprehensive reports allowing
at-a-glance performance assessment
For EQA to be fully effective in improving laboratory performance, we must train laboratory staff on the importance
of Quality Management, and more specifically on the application of EQA programmes and the interpretation of the
reports that are generated. Training modules available to participating laboratories include:
• Importance of Quality Assurance and Quality Control in the Laboratory Setting
• Eliminating Analytical Error: Identifying Random and Systematic error
• Quality tools to reduce cost and improve the quality of patient results
• ISO15189 & ISO 17043- Quality Accreditation in the Clinical Laboratory
• Troubleshooting laboratory errors - workshop
• EQA report interpretation - workshop
• Pre-analytical, analytical and post analytical error - workshop
Randox continues to bring innovative new products to the IVD market every year, investing up to 16% of revenue in
R&D. With around 25% of the company’s personnel focused on research and engineering, Randox is, and will continue
to be, at the cutting edge of a fast moving dynamic industry.
Randox: Committed to Training and Education
The only provider to fully meet these requirements is RIQAS; the world’s EQA scheme of choice
Randox Laboratories Ltd, 55 Diamond Road, Crumlin, County Antrim, BT29 4QY, United Kingdom
+44 (0) 28 9442 2413 +44 (0) 28 9445 2912 marketing@randox.com randoxqc.com
Information correct at time of print. Randox Laboratories Ltd is a subsidiary of Randox Holdings Limited a company registered within Northern Ireland with company number N.I. 614690. VAT Registered Number: GB 151
6827 08. Product availability may vary from country to country. Please contact your local Randox representative for information. Products may be for Research Use Only and not for use in diagnostic procedures in the USA.
QUALITY CONTROL
find out more
LT649JUN15
Comprising almost 360 routine and esoteric parameters in 24 comprehensive
and flexible EQA programmes, RIQAS is designed to cover all areas of clinical
testing. Each programme benefits from a wide range of concentrations, frequent
reporting and comprehensive yet user-friendly reports.
The largest global EQA scheme with over 31,000 lab participants
mail@riqas.com riqas.net riqas.com
abc
RIQAS
Programme
Parameter
Options
RIQAS
Programme
Parameter
Options
Ammonia/Etanol 2 Immunoassay Speciality II 5
Blood Gas 10 Lipid 3/7
BNP 1 Liquid Cardiac 9
Cardiac 2/7 Maternal Screening 6
Coagulation 5/17 Serology (EBV) 3
ESR 1 Serology (HIV/Hepatitis) 10
General Clinical Chemistry 10/17/50 Serology (Syphilis) 1
Glycated Haemoglobin 2 Serology (ToRCH) 12
Haematology 11 Specific Proteins 26
Human Urine 25 Therapeutic Drugs 18
Immunoassay 4/13/55 Urinalysis 14
Immunoassay Speciality I 10 Urine Toxicology 20

Mais conteúdo relacionado

Mais procurados

Monitoring EQA / PT Performance
Monitoring EQA / PT PerformanceMonitoring EQA / PT Performance
Monitoring EQA / PT PerformanceRandox
 
Quality control in the medical laboratory
Quality control in the medical laboratoryQuality control in the medical laboratory
Quality control in the medical laboratoryAdnan Jaran
 
(IQC) - Internal Quality Control.pptx
(IQC) - Internal Quality Control.pptx(IQC) - Internal Quality Control.pptx
(IQC) - Internal Quality Control.pptxDr.Rajeev Ranjan
 
Laboratory Internal Quality Control presentation master revision, 2014
Laboratory Internal Quality Control presentation master revision, 2014Laboratory Internal Quality Control presentation master revision, 2014
Laboratory Internal Quality Control presentation master revision, 2014Adel Elazab Elged
 
Post analytical variables in Laboratory
Post analytical variables in LaboratoryPost analytical variables in Laboratory
Post analytical variables in Laboratorywww.jaailab.com
 
Internal quality control in clinical laboratories hematology(2)
Internal quality control in clinical laboratories hematology(2)Internal quality control in clinical laboratories hematology(2)
Internal quality control in clinical laboratories hematology(2)NAZAR ABU-DULLA
 
Pre analytical errors
Pre analytical errorsPre analytical errors
Pre analytical errorsNasir Nazeer
 
Quality assurance in the department of clinical biochemistry
Quality assurance in the department of clinical biochemistryQuality assurance in the department of clinical biochemistry
Quality assurance in the department of clinical biochemistryDipesh Tamrakar
 
Presentation on ISO 15189 documentation
Presentation on ISO 15189 documentationPresentation on ISO 15189 documentation
Presentation on ISO 15189 documentationGlobal Manager Group
 
Point of care testing ( POCT)
Point of care testing ( POCT)Point of care testing ( POCT)
Point of care testing ( POCT)binaya tamang
 
PRE AND POST ANALYTICAL ERRORS
PRE AND POST ANALYTICAL ERRORSPRE AND POST ANALYTICAL ERRORS
PRE AND POST ANALYTICAL ERRORSMoustafa Rezk
 
quality control in clinical pathology
quality control in clinical pathologyquality control in clinical pathology
quality control in clinical pathologyIshaque Vadakkethil
 
Automation in the Clinical Lab
Automation in the Clinical LabAutomation in the Clinical Lab
Automation in the Clinical LabAli Raza Ph.D
 

Mais procurados (20)

Total Quality Management in Medical Laboratories
Total Quality Management in Medical LaboratoriesTotal Quality Management in Medical Laboratories
Total Quality Management in Medical Laboratories
 
Monitoring EQA / PT Performance
Monitoring EQA / PT PerformanceMonitoring EQA / PT Performance
Monitoring EQA / PT Performance
 
Quality control in the medical laboratory
Quality control in the medical laboratoryQuality control in the medical laboratory
Quality control in the medical laboratory
 
(IQC) - Internal Quality Control.pptx
(IQC) - Internal Quality Control.pptx(IQC) - Internal Quality Control.pptx
(IQC) - Internal Quality Control.pptx
 
Quality management
Quality managementQuality management
Quality management
 
Laboratory Internal Quality Control presentation master revision, 2014
Laboratory Internal Quality Control presentation master revision, 2014Laboratory Internal Quality Control presentation master revision, 2014
Laboratory Internal Quality Control presentation master revision, 2014
 
Post analytical variables in Laboratory
Post analytical variables in LaboratoryPost analytical variables in Laboratory
Post analytical variables in Laboratory
 
Laboratory management
Laboratory managementLaboratory management
Laboratory management
 
Quality assurance in a medical laboratory
Quality assurance in a medical laboratoryQuality assurance in a medical laboratory
Quality assurance in a medical laboratory
 
Internal quality control in clinical laboratories hematology(2)
Internal quality control in clinical laboratories hematology(2)Internal quality control in clinical laboratories hematology(2)
Internal quality control in clinical laboratories hematology(2)
 
Pre analytical errors
Pre analytical errorsPre analytical errors
Pre analytical errors
 
Troubleshooting IQC / EQAS
Troubleshooting IQC / EQASTroubleshooting IQC / EQAS
Troubleshooting IQC / EQAS
 
Quality Control
Quality ControlQuality Control
Quality Control
 
Quality assurance in the department of clinical biochemistry
Quality assurance in the department of clinical biochemistryQuality assurance in the department of clinical biochemistry
Quality assurance in the department of clinical biochemistry
 
Presentation on ISO 15189 documentation
Presentation on ISO 15189 documentationPresentation on ISO 15189 documentation
Presentation on ISO 15189 documentation
 
Troubleshooting iqc eqas 19.07.2018
Troubleshooting iqc eqas 19.07.2018Troubleshooting iqc eqas 19.07.2018
Troubleshooting iqc eqas 19.07.2018
 
Point of care testing ( POCT)
Point of care testing ( POCT)Point of care testing ( POCT)
Point of care testing ( POCT)
 
PRE AND POST ANALYTICAL ERRORS
PRE AND POST ANALYTICAL ERRORSPRE AND POST ANALYTICAL ERRORS
PRE AND POST ANALYTICAL ERRORS
 
quality control in clinical pathology
quality control in clinical pathologyquality control in clinical pathology
quality control in clinical pathology
 
Automation in the Clinical Lab
Automation in the Clinical LabAutomation in the Clinical Lab
Automation in the Clinical Lab
 

Destaque

Troubleshooting Poor EQA/QC Performance in the Laboratory
Troubleshooting Poor EQA/QC Performance in the Laboratory Troubleshooting Poor EQA/QC Performance in the Laboratory
Troubleshooting Poor EQA/QC Performance in the Laboratory Randox
 
Troubleshooting QC Problems: Your QC has failed, what do you do next?
Troubleshooting QC Problems: Your QC has failed, what do you do next?Troubleshooting QC Problems: Your QC has failed, what do you do next?
Troubleshooting QC Problems: Your QC has failed, what do you do next?Randox
 
Designing an appropriate QC procedure for your laboratory
Designing an appropriate QC procedure for your laboratoryDesigning an appropriate QC procedure for your laboratory
Designing an appropriate QC procedure for your laboratoryRandox
 
Improving Laboratory Performance Through Quality Control - The role of EQA in...
Improving Laboratory Performance Through Quality Control - The role of EQA in...Improving Laboratory Performance Through Quality Control - The role of EQA in...
Improving Laboratory Performance Through Quality Control - The role of EQA in...Randox
 
RIQAS External Quality Assessment for Medical Laboratories
RIQAS External Quality Assessment for Medical Laboratories RIQAS External Quality Assessment for Medical Laboratories
RIQAS External Quality Assessment for Medical Laboratories Randox
 
ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...
ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...
ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...Randox
 
Monitoring EQA/PT Performance (Polish)
Monitoring EQA/PT Performance (Polish)Monitoring EQA/PT Performance (Polish)
Monitoring EQA/PT Performance (Polish)Randox
 
Quality control in clinical laboratory
Quality control in clinical laboratoryQuality control in clinical laboratory
Quality control in clinical laboratorydrgomi basar
 
EAS Overview Presentation
EAS Overview PresentationEAS Overview Presentation
EAS Overview PresentationIan Grant-Smith
 
New summary interlaboratory & summary instrument group reports mar15 ita
New summary interlaboratory & summary instrument group reports mar15 itaNew summary interlaboratory & summary instrument group reports mar15 ita
New summary interlaboratory & summary instrument group reports mar15 itaRandox
 
New summary interlaboratory & summary instrument group reports mar15 rus
New summary interlaboratory & summary instrument group reports mar15 rusNew summary interlaboratory & summary instrument group reports mar15 rus
New summary interlaboratory & summary instrument group reports mar15 rusRandox
 
New summary interlaboratory & summary instrument group reports mar15 svk
New summary interlaboratory & summary instrument group reports mar15 svkNew summary interlaboratory & summary instrument group reports mar15 svk
New summary interlaboratory & summary instrument group reports mar15 svkRandox
 
Consolidate & Save
Consolidate & SaveConsolidate & Save
Consolidate & SaveRandox
 
ACB Focus 2015 Poster
ACB Focus 2015 PosterACB Focus 2015 Poster
ACB Focus 2015 PosterRandox
 
Guide to running QC
Guide to running QCGuide to running QC
Guide to running QCRandox
 
How often is Right for Laboratory Quality Control?
How often is Right for Laboratory Quality Control?How often is Right for Laboratory Quality Control?
How often is Right for Laboratory Quality Control?Randox
 
Acusera Third Party Quality Controls for Medical Laboratories
Acusera Third Party Quality Controls for Medical Laboratories Acusera Third Party Quality Controls for Medical Laboratories
Acusera Third Party Quality Controls for Medical Laboratories Randox
 
New summary interlaboratory & summary instrument group reports mar15 prt
New summary interlaboratory & summary instrument group reports mar15 prtNew summary interlaboratory & summary instrument group reports mar15 prt
New summary interlaboratory & summary instrument group reports mar15 prtRandox
 
Uso de Multireglas CC
Uso de Multireglas CCUso de Multireglas CC
Uso de Multireglas CCRandox
 

Destaque (20)

Troubleshooting Poor EQA/QC Performance in the Laboratory
Troubleshooting Poor EQA/QC Performance in the Laboratory Troubleshooting Poor EQA/QC Performance in the Laboratory
Troubleshooting Poor EQA/QC Performance in the Laboratory
 
Troubleshooting QC Problems: Your QC has failed, what do you do next?
Troubleshooting QC Problems: Your QC has failed, what do you do next?Troubleshooting QC Problems: Your QC has failed, what do you do next?
Troubleshooting QC Problems: Your QC has failed, what do you do next?
 
Designing an appropriate QC procedure for your laboratory
Designing an appropriate QC procedure for your laboratoryDesigning an appropriate QC procedure for your laboratory
Designing an appropriate QC procedure for your laboratory
 
Improving Laboratory Performance Through Quality Control - The role of EQA in...
Improving Laboratory Performance Through Quality Control - The role of EQA in...Improving Laboratory Performance Through Quality Control - The role of EQA in...
Improving Laboratory Performance Through Quality Control - The role of EQA in...
 
RIQAS External Quality Assessment for Medical Laboratories
RIQAS External Quality Assessment for Medical Laboratories RIQAS External Quality Assessment for Medical Laboratories
RIQAS External Quality Assessment for Medical Laboratories
 
ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...
ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...
ISO 15189 Accreditation Guide - Improving Laboratory Performance Through Qual...
 
Monitoring EQA/PT Performance (Polish)
Monitoring EQA/PT Performance (Polish)Monitoring EQA/PT Performance (Polish)
Monitoring EQA/PT Performance (Polish)
 
Quality control in clinical laboratory
Quality control in clinical laboratoryQuality control in clinical laboratory
Quality control in clinical laboratory
 
EAS Overview Presentation
EAS Overview PresentationEAS Overview Presentation
EAS Overview Presentation
 
Iqc Eqa Pt มน
Iqc Eqa Pt มนIqc Eqa Pt มน
Iqc Eqa Pt มน
 
New summary interlaboratory & summary instrument group reports mar15 ita
New summary interlaboratory & summary instrument group reports mar15 itaNew summary interlaboratory & summary instrument group reports mar15 ita
New summary interlaboratory & summary instrument group reports mar15 ita
 
New summary interlaboratory & summary instrument group reports mar15 rus
New summary interlaboratory & summary instrument group reports mar15 rusNew summary interlaboratory & summary instrument group reports mar15 rus
New summary interlaboratory & summary instrument group reports mar15 rus
 
New summary interlaboratory & summary instrument group reports mar15 svk
New summary interlaboratory & summary instrument group reports mar15 svkNew summary interlaboratory & summary instrument group reports mar15 svk
New summary interlaboratory & summary instrument group reports mar15 svk
 
Consolidate & Save
Consolidate & SaveConsolidate & Save
Consolidate & Save
 
ACB Focus 2015 Poster
ACB Focus 2015 PosterACB Focus 2015 Poster
ACB Focus 2015 Poster
 
Guide to running QC
Guide to running QCGuide to running QC
Guide to running QC
 
How often is Right for Laboratory Quality Control?
How often is Right for Laboratory Quality Control?How often is Right for Laboratory Quality Control?
How often is Right for Laboratory Quality Control?
 
Acusera Third Party Quality Controls for Medical Laboratories
Acusera Third Party Quality Controls for Medical Laboratories Acusera Third Party Quality Controls for Medical Laboratories
Acusera Third Party Quality Controls for Medical Laboratories
 
New summary interlaboratory & summary instrument group reports mar15 prt
New summary interlaboratory & summary instrument group reports mar15 prtNew summary interlaboratory & summary instrument group reports mar15 prt
New summary interlaboratory & summary instrument group reports mar15 prt
 
Uso de Multireglas CC
Uso de Multireglas CCUso de Multireglas CC
Uso de Multireglas CC
 

Semelhante a EQA: An Essential Tool for Laboratory Quality - Africa LT649

Quality control in a virology laboratory.pdf
Quality control in a virology laboratory.pdfQuality control in a virology laboratory.pdf
Quality control in a virology laboratory.pdfsamwel18
 
Group_3_M - Cancer Research Laboratory.pptx
Group_3_M - Cancer Research Laboratory.pptxGroup_3_M - Cancer Research Laboratory.pptx
Group_3_M - Cancer Research Laboratory.pptxNafeesaHanif1
 
Point Of Care Testing
Point Of Care TestingPoint Of Care Testing
Point Of Care TestingLAB IDEA
 
Significance of CAP accreditation
Significance of CAP accreditationSignificance of CAP accreditation
Significance of CAP accreditationBilal Al-kadri
 
Clia final regulations
Clia final regulationsClia final regulations
Clia final regulationsMoustafa Rezk
 
Quality Assurance Qual Indicators.ppt
Quality Assurance Qual Indicators.pptQuality Assurance Qual Indicators.ppt
Quality Assurance Qual Indicators.pptSUNILDhatwalia1
 
Quality Assurance and Quality Control
Quality Assurance and Quality ControlQuality Assurance and Quality Control
Quality Assurance and Quality ControlECRD IN
 
Quality assurance and quality control
Quality assurance and quality controlQuality assurance and quality control
Quality assurance and quality controlECRD2015
 
Chapter 12
Chapter 12Chapter 12
Chapter 12ECRD IN
 
Improving Laboratory Performance Through QC - Commutability
Improving Laboratory Performance Through QC - CommutabilityImproving Laboratory Performance Through QC - Commutability
Improving Laboratory Performance Through QC - CommutabilityRandox
 
Total Quality Management (TQM) by Dr Anurag Yadav
Total Quality Management (TQM) by Dr Anurag YadavTotal Quality Management (TQM) by Dr Anurag Yadav
Total Quality Management (TQM) by Dr Anurag YadavDr Anurag Yadav
 
Perez.pptx
Perez.pptxPerez.pptx
Perez.pptxjnrkwesi
 
Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...
Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...
Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...Randox
 
Medical Laboratory Accreditation and its utilization in Japan - Katsuo Kubono
Medical Laboratory Accreditation and its utilization in Japan - Katsuo KubonoMedical Laboratory Accreditation and its utilization in Japan - Katsuo Kubono
Medical Laboratory Accreditation and its utilization in Japan - Katsuo KubonoMara International
 
White Paper Quality Control for Point of Care Testing
White Paper Quality Control for Point of Care TestingWhite Paper Quality Control for Point of Care Testing
White Paper Quality Control for Point of Care TestingRandox
 
Quality Control for Point of Care Testing - White Paper
Quality Control for Point of Care Testing - White PaperQuality Control for Point of Care Testing - White Paper
Quality Control for Point of Care Testing - White PaperRandox
 
Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stround
 Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stround Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stround
Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stroundhydrologywebsite1
 

Semelhante a EQA: An Essential Tool for Laboratory Quality - Africa LT649 (20)

What is the EQA process.pdf
What is the EQA process.pdfWhat is the EQA process.pdf
What is the EQA process.pdf
 
Quality control in a virology laboratory.pdf
Quality control in a virology laboratory.pdfQuality control in a virology laboratory.pdf
Quality control in a virology laboratory.pdf
 
Group_3_M - Cancer Research Laboratory.pptx
Group_3_M - Cancer Research Laboratory.pptxGroup_3_M - Cancer Research Laboratory.pptx
Group_3_M - Cancer Research Laboratory.pptx
 
Point Of Care Testing
Point Of Care TestingPoint Of Care Testing
Point Of Care Testing
 
Significance of CAP accreditation
Significance of CAP accreditationSignificance of CAP accreditation
Significance of CAP accreditation
 
Clia final regulations
Clia final regulationsClia final regulations
Clia final regulations
 
Quality Assurance Qual Indicators.ppt
Quality Assurance Qual Indicators.pptQuality Assurance Qual Indicators.ppt
Quality Assurance Qual Indicators.ppt
 
Quality Assurance and Quality Control
Quality Assurance and Quality ControlQuality Assurance and Quality Control
Quality Assurance and Quality Control
 
Quality assurance and quality control
Quality assurance and quality controlQuality assurance and quality control
Quality assurance and quality control
 
Chapter 12
Chapter 12Chapter 12
Chapter 12
 
Improving Laboratory Performance Through QC - Commutability
Improving Laboratory Performance Through QC - CommutabilityImproving Laboratory Performance Through QC - Commutability
Improving Laboratory Performance Through QC - Commutability
 
Total Quality Management (TQM) by Dr Anurag Yadav
Total Quality Management (TQM) by Dr Anurag YadavTotal Quality Management (TQM) by Dr Anurag Yadav
Total Quality Management (TQM) by Dr Anurag Yadav
 
Perez.pptx
Perez.pptxPerez.pptx
Perez.pptx
 
Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...
Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...
Basic QC Statistics - Improving Laboratory Performance Through Quality Contro...
 
AWARE - Providin High Value
AWARE - Providin High ValueAWARE - Providin High Value
AWARE - Providin High Value
 
Medical Laboratory Accreditation and its utilization in Japan - Katsuo Kubono
Medical Laboratory Accreditation and its utilization in Japan - Katsuo KubonoMedical Laboratory Accreditation and its utilization in Japan - Katsuo Kubono
Medical Laboratory Accreditation and its utilization in Japan - Katsuo Kubono
 
White Paper Quality Control for Point of Care Testing
White Paper Quality Control for Point of Care TestingWhite Paper Quality Control for Point of Care Testing
White Paper Quality Control for Point of Care Testing
 
Quality Control for Point of Care Testing - White Paper
Quality Control for Point of Care Testing - White PaperQuality Control for Point of Care Testing - White Paper
Quality Control for Point of Care Testing - White Paper
 
Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stround
 Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stround Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stround
Download-manuals-water quality-wq-manuals-within-labaqcfindings-1stround
 
ACE @ 25 nomination
ACE @ 25 nominationACE @ 25 nomination
ACE @ 25 nomination
 

Mais de Randox

How to establish QC reference ranges - Randox QC Educational Guide
How to establish QC reference ranges - Randox QC Educational GuideHow to establish QC reference ranges - Randox QC Educational Guide
How to establish QC reference ranges - Randox QC Educational GuideRandox
 
Acusera Third Party Controls
Acusera Third Party ControlsAcusera Third Party Controls
Acusera Third Party ControlsRandox
 
Acusera 24.7 QC Data Management
Acusera 24.7 QC Data ManagementAcusera 24.7 QC Data Management
Acusera 24.7 QC Data ManagementRandox
 
Acusera 24.7 Interlaboratory Data Management - June 17 LT244
Acusera 24.7 Interlaboratory Data Management - June 17 LT244Acusera 24.7 Interlaboratory Data Management - June 17 LT244
Acusera 24.7 Interlaboratory Data Management - June 17 LT244Randox
 
Acusera Verify Linearity Verification - June 17 LT674
Acusera Verify Linearity Verification - June 17 LT674Acusera Verify Linearity Verification - June 17 LT674
Acusera Verify Linearity Verification - June 17 LT674Randox
 
LT033 RIQAS Explained MAY17
LT033 RIQAS Explained MAY17LT033 RIQAS Explained MAY17
LT033 RIQAS Explained MAY17Randox
 
LT027 Acusera Third Party Controls May17
LT027 Acusera Third Party Controls May17LT027 Acusera Third Party Controls May17
LT027 Acusera Third Party Controls May17Randox
 
Randox QC Pancake IFU
Randox QC Pancake IFURandox QC Pancake IFU
Randox QC Pancake IFURandox
 
RIQAS Calendar 2017
RIQAS Calendar 2017RIQAS Calendar 2017
RIQAS Calendar 2017Randox
 
Step by Step Guide to Preparing QC
Step by Step Guide to Preparing QCStep by Step Guide to Preparing QC
Step by Step Guide to Preparing QCRandox
 
The Importance of Third Party Controls
The Importance of Third Party ControlsThe Importance of Third Party Controls
The Importance of Third Party ControlsRandox
 
What format is best for your laboratory
What format is best for your laboratoryWhat format is best for your laboratory
What format is best for your laboratoryRandox
 
Designing an appropriate qc design procedure for your lab 5 mar15
Designing an appropriate qc design procedure for your lab 5 mar15Designing an appropriate qc design procedure for your lab 5 mar15
Designing an appropriate qc design procedure for your lab 5 mar15Randox
 
Using QC Multi-rules
Using QC Multi-rulesUsing QC Multi-rules
Using QC Multi-rulesRandox
 
QC Multi rules - Improving Laboratory Performance Through Quality Control
QC Multi rules - Improving Laboratory Performance Through Quality ControlQC Multi rules - Improving Laboratory Performance Through Quality Control
QC Multi rules - Improving Laboratory Performance Through Quality ControlRandox
 
Acusera Verify Presentation
Acusera Verify PresentationAcusera Verify Presentation
Acusera Verify PresentationRandox
 
FOCUS 2016 Poster: Specific Proteins
FOCUS 2016 Poster: Specific ProteinsFOCUS 2016 Poster: Specific Proteins
FOCUS 2016 Poster: Specific ProteinsRandox
 
How to Measure Uncertainty
How to Measure UncertaintyHow to Measure Uncertainty
How to Measure UncertaintyRandox
 

Mais de Randox (18)

How to establish QC reference ranges - Randox QC Educational Guide
How to establish QC reference ranges - Randox QC Educational GuideHow to establish QC reference ranges - Randox QC Educational Guide
How to establish QC reference ranges - Randox QC Educational Guide
 
Acusera Third Party Controls
Acusera Third Party ControlsAcusera Third Party Controls
Acusera Third Party Controls
 
Acusera 24.7 QC Data Management
Acusera 24.7 QC Data ManagementAcusera 24.7 QC Data Management
Acusera 24.7 QC Data Management
 
Acusera 24.7 Interlaboratory Data Management - June 17 LT244
Acusera 24.7 Interlaboratory Data Management - June 17 LT244Acusera 24.7 Interlaboratory Data Management - June 17 LT244
Acusera 24.7 Interlaboratory Data Management - June 17 LT244
 
Acusera Verify Linearity Verification - June 17 LT674
Acusera Verify Linearity Verification - June 17 LT674Acusera Verify Linearity Verification - June 17 LT674
Acusera Verify Linearity Verification - June 17 LT674
 
LT033 RIQAS Explained MAY17
LT033 RIQAS Explained MAY17LT033 RIQAS Explained MAY17
LT033 RIQAS Explained MAY17
 
LT027 Acusera Third Party Controls May17
LT027 Acusera Third Party Controls May17LT027 Acusera Third Party Controls May17
LT027 Acusera Third Party Controls May17
 
Randox QC Pancake IFU
Randox QC Pancake IFURandox QC Pancake IFU
Randox QC Pancake IFU
 
RIQAS Calendar 2017
RIQAS Calendar 2017RIQAS Calendar 2017
RIQAS Calendar 2017
 
Step by Step Guide to Preparing QC
Step by Step Guide to Preparing QCStep by Step Guide to Preparing QC
Step by Step Guide to Preparing QC
 
The Importance of Third Party Controls
The Importance of Third Party ControlsThe Importance of Third Party Controls
The Importance of Third Party Controls
 
What format is best for your laboratory
What format is best for your laboratoryWhat format is best for your laboratory
What format is best for your laboratory
 
Designing an appropriate qc design procedure for your lab 5 mar15
Designing an appropriate qc design procedure for your lab 5 mar15Designing an appropriate qc design procedure for your lab 5 mar15
Designing an appropriate qc design procedure for your lab 5 mar15
 
Using QC Multi-rules
Using QC Multi-rulesUsing QC Multi-rules
Using QC Multi-rules
 
QC Multi rules - Improving Laboratory Performance Through Quality Control
QC Multi rules - Improving Laboratory Performance Through Quality ControlQC Multi rules - Improving Laboratory Performance Through Quality Control
QC Multi rules - Improving Laboratory Performance Through Quality Control
 
Acusera Verify Presentation
Acusera Verify PresentationAcusera Verify Presentation
Acusera Verify Presentation
 
FOCUS 2016 Poster: Specific Proteins
FOCUS 2016 Poster: Specific ProteinsFOCUS 2016 Poster: Specific Proteins
FOCUS 2016 Poster: Specific Proteins
 
How to Measure Uncertainty
How to Measure UncertaintyHow to Measure Uncertainty
How to Measure Uncertainty
 

EQA: An Essential Tool for Laboratory Quality - Africa LT649

  • 1. External Quailty Assessment: an Essential Tool for Laboratory Quality QUALITY CONTROL Complete QC solutions for results you can trust
  • 2. Considering that 75% of the information used by physicians to make a diagnosis is derived from laboratory test results, it is vital that laboratories perform regular checks to ensure the results released are accurate and reliable. The objective of Quality Control is to detect laboratory errors and ultimately, prevent the release of inaccurate test results which could lead to misdiagnosis, inappropriate treatment or treatment delays, all of which could be potentially life threatening for the patient. Quality Control will also decrease the need for repeat tests, directly reducing costs as a result. A good Quality Control programme should incorporate both Internal Quality Control (IQC) and External Quality Assessment (EQA). The use of IQC alone is not a sufficient measure of laboratory performance. Participation in an EQA scheme is also required to ensure confidence in patient results. While IQC will effectively monitor the reproducibility or precision of laboratory testing, it doesn’t enable laboratories to monitor bias or accuracy. Accuracy refers to how close the result generated by the laboratory is to the true value of the sample. In order to effectively monitor accuracy, laboratories must participate in an EQA programme. Best Laboratory Prctices ‘The laboratory shall participate in interlaboratory comparisons such as those organised by external quality assessment programmes. Laboratory management shall monitor the results of external quality assessment and participate in the implementation of corrective actions when performance criteria are not fulfilled’ ISO 15189:2012 Medical Laboratories: Requirements for quality and competence Internal Quality Control External Quality Assessment Total Quality Assurance EQA: an Essential Tool for Laboratory Quality
  • 3. Implementation of an EQA scheme,although appearing to represent additional costs to the laboratory’s budget,will in the long term decrease expenditure, increase productivity and, most importantly, improve performance and minimise patient risk. Benefits of EQA EQA – More than just Accreditation • Provides management with an holistic view of test system performance that IQC alone cannot provide • Identify potential equipment or reagent faults as well as staff training requirements and issues with staff competency • Reduce the cost and time associated with expensive repeat tests • Compare performance with other analytical methods on the market • Initiate corrective action and evaluate the effectiveness of corrective actions • Provides an independent assessment of laboratory accuracy for added confidence in patient test results What Medical Professionals Say About EQA The following real life testimonials show how EQA has helped laboratories in Africa to improve quality and performance. “EQA has proved to be of huge benefit to our laboratory. This is mainly because of the narrow SD which ensures that only accurate results are acceptable. EQA has been an eye opener to the shortfalls of our lab. We expect our performance to improve and subsequently our reliability to clinicians.” Tinei Makurumure, Quality Assurance Manager, Multi-Tech Diagnostics, Harare, Zimbabwe “EQA has helped me and my team to identify problems associated with the calibration of my analyser. This has been extremely beneficial in running my lab. It gives me confidence in my results and indicates where problems may arise.” Mrs Anya, Laboratory Manager, Reddington Hospital, Lagos Nigeria “EQA has improved our laboratory performance and increased our confidence. A good EQA scheme has the potential to offer a wide range of parameters, covering a broad spectrum, rapid turnaround of results and user-friendly reports. It should provide Multi – Instrument reports, allowing a laboratory to compare accuracy between their instruments.” Dr Veena Vyas, Head of Department (Pathology) The Aga Khan Hospital, Dar es Salaam, Tanzania “The Nairobi hospital has been using EQA for more than two decades and throughout this period we have been happy partners. EQA provides samples that cover our entire test panel including; blood gas, therapeutic drugs, immunoassay, biochemistry, urinalysis & haematology. Frequent samples are most appropriate for our hospital enabling us to identify non-conforming tests quickly. A good EQA scheme will provide a good reporting format to interpret results and enable us to sustain our ISO 15189 accreditation.” Dr Peter Kariuki, Deputy Manager of Laboratory Services, The Nairobi Hospital, Nairobi, Kenya “Our laboratory is a hospital and clinical lab which seeks high technical quality to ensure reliable results. That is why we enrolled for an EQA programme, aware that it provides valuable data and information which will ensure accurate results for our customers, e.g., physicians, patients, health authorities and NGOs alike. EQA provides early warning to problems in laboratory practices, allowing appropriate corrective action and continuous quality improvement.” Mrs Maria Santo, Laboratory Manager, ICOR - Instituto do Coração Maputo, Mozambique
  • 4. Real Life Case Studies Highlighting the Importance of Running Both IQC and EQA in a Laboratory The following case studies highlight the importance of participating in a reputable EQA scheme in addition to daily IQC to ensure laboratory quality and prevent the release of incorrect patient results, which could be potentially life threatening. Detecting Concentration Issues • Upon the review of their EQA report, Laboratory ‘A’ observed poor performance for Procalcitonin. This was evident from the report’s Levey-Jennings chart, which showed erratic dispersal of results.The laboratory’s 1st Party IQC results however, remained within acceptable ranges • On examining the 1st party IQC kit inserts it was evident that the level 1 and level 3 were not at clinically relevant levels and were not accurately assessing the full range of the assay Conclusion A good EQA scheme provides samples covering a wider spread of concentrations. Therefore, the EQA highlighted the weaknesses of the range of the Procalcitonin assay which the laboratory’s 1st Party IQC failed to detect. Detecting Issues Hidden by Inadequate IQC • Laboratory ‘B’ received EQA reports highlighting poor EQA performance for Amylase but their IQC results were within 2SD limits •The laboratory contacted their EQA provider who explained that although their IQC results were within 2SD, when the % deviation from the target is calculated 2SD was equal to 20% •The acceptable limits of performance used by the EQA scheme were much narrower, where 2SD was equal to 10% of the target value •Therefore EQA proved to be a more stringent assessment of the laboratory’s performance Conclusion In this example, participation in an EQA scheme highlighted that the acceptable ranges provided by the QC manufacturer were unrealistically wide, thus masking an issue with the test system and ultimately resulting in the laboratory falsely believing that its results were accurate. Financial and Human Impact of Misdiagnosis Avoidable repeat tests cost the US $200 million every year “Globally, best estimates put the incidence of diagnostic error in assessing patients in the range of 10% to 15%” (1) Studies put the number of diagnostic errors in Australia at 140,000 cases a year, with 21,000 cases of serious harm and between 2000 and 4000 deaths. In 2008, medical errors cost the United States $19.5 billion. About 87% or $17 billion were directly associated with additional medical cost, including: ancillary services, prescription drug services, and inpatient and outpatient care. (2) 1. http://theconversation.com/the-hidden-problem-of-medical-misdiagnosis-and-how-to-fix-it-14662 2. J Health Care Finance. 2012 fall; 39(1):39-50.The economics of health care quality and medical errors. Andel C1, Davidow SL, Hollander M, Moreno DA
  • 5. How does EQA Work? EQA provides a means of periodically assessing laboratory performance in comparison with other laboratories using the same method and instrument. Unlike IQC, EQA provides an effective method of monitoring a laboratory’s bias or accuracy through the analysis of samples of unknown concentrations, otherwise known as ‘blind samples’. It also enables assessment of the complete testing process including pre-analytical, analytical and post analytical phases. After analysis,results are submitted to the scheme organiser for statistical evaluation. Laboratories will subsequently receive a report comparing their performance to that of other participants in the programme.The diagram below illustrates how EQA works. REGISTER 1 36.000 mg/dl 84.800 IU/ml 132.000 ng/ml Certificate of Participation Stephen Doherty RIQAS Manager Randox International Quality Assessment Scheme Randox Laboratories Ltd., 55 Diamond Road, Crumlin, Co.Antrim, BT29 4QY, United Kingdom PR-281APR15 <Name> <Laboratory/Hospital> abc Place an order with your local Randox representative. Register by completing enrolment document and submit at least 3 weeks before the cycle starts 1 You will receive a set of numbered samples for the cycle along with a username/password for RIQAS.Net * 2 Analyse the sample on the recommended date 3 Enter and submit results online before the final deadline 4 Receive report within 72 hours and review to assess performance 5 Certificates will be awarded at the end of the cycle providing that more than half of the results are returned 6 QUALITY CONTROL * Provision can be made for labs without internet access
  • 6. Levey-Jennings Levey-Jennings charts are useful for monitoring performance over time, allowing instant identification of any trends or bias. Ideally, results should fall within 1SD (white region) either side of the mean. Participation in an EQA scheme alone will not automatically improve quality or performance. Perhaps the main value of participating in an EQA scheme lies in the report generated by the scheme provider. Not only should reports be comprehensive, covering a wide range of statistics and charts, it is also important that they are user-friendly and easy to interpret. The ability to understand an EQA report will maximise the benefits of participating in an EQA scheme. Understanding EQA Reports: the key to improving performance and quality Histogram Histograms provide a quick, visual indication of how your laboratory performs in relation to the instrument mean, method mean and all method mean. % Deviation by concentration chart Helps to quickly and easily identify any concentration related bias within a test system. Target score chart Unique to RIQAS, theTarget Score chart provides a visual indication of performance for the last 20 samples. A target score of 50 or more is considered acceptable.
  • 7. When choosing an EQA scheme to complement your IQC there are several factors to be considered. The below checklist is designed to help you choose, not only the most cost effective, but the highest quality EQA scheme. Essential Criteria for Choosing an EQA Scheme • Large number of participants increasing statistical validity and ensuring availability of peer group data for a wide range of analytical methods • Accreditation to ISO/IEC 17043:2010 • Frequent analysis ensuring system errors are identified as early as possible • Rapid report turnaround allowing corrective actions to be taken immediately with minimum risk to patients • Samples that cover the complete clinical range and behave in the same manner as patient samples • Ability to register multiple instruments • Multi-analyte programmes allowing effective consolidation • User-friendly yet comprehensive reports allowing at-a-glance performance assessment For EQA to be fully effective in improving laboratory performance, we must train laboratory staff on the importance of Quality Management, and more specifically on the application of EQA programmes and the interpretation of the reports that are generated. Training modules available to participating laboratories include: • Importance of Quality Assurance and Quality Control in the Laboratory Setting • Eliminating Analytical Error: Identifying Random and Systematic error • Quality tools to reduce cost and improve the quality of patient results • ISO15189 & ISO 17043- Quality Accreditation in the Clinical Laboratory • Troubleshooting laboratory errors - workshop • EQA report interpretation - workshop • Pre-analytical, analytical and post analytical error - workshop Randox continues to bring innovative new products to the IVD market every year, investing up to 16% of revenue in R&D. With around 25% of the company’s personnel focused on research and engineering, Randox is, and will continue to be, at the cutting edge of a fast moving dynamic industry. Randox: Committed to Training and Education The only provider to fully meet these requirements is RIQAS; the world’s EQA scheme of choice
  • 8. Randox Laboratories Ltd, 55 Diamond Road, Crumlin, County Antrim, BT29 4QY, United Kingdom +44 (0) 28 9442 2413 +44 (0) 28 9445 2912 marketing@randox.com randoxqc.com Information correct at time of print. Randox Laboratories Ltd is a subsidiary of Randox Holdings Limited a company registered within Northern Ireland with company number N.I. 614690. VAT Registered Number: GB 151 6827 08. Product availability may vary from country to country. Please contact your local Randox representative for information. Products may be for Research Use Only and not for use in diagnostic procedures in the USA. QUALITY CONTROL find out more LT649JUN15 Comprising almost 360 routine and esoteric parameters in 24 comprehensive and flexible EQA programmes, RIQAS is designed to cover all areas of clinical testing. Each programme benefits from a wide range of concentrations, frequent reporting and comprehensive yet user-friendly reports. The largest global EQA scheme with over 31,000 lab participants mail@riqas.com riqas.net riqas.com abc RIQAS Programme Parameter Options RIQAS Programme Parameter Options Ammonia/Etanol 2 Immunoassay Speciality II 5 Blood Gas 10 Lipid 3/7 BNP 1 Liquid Cardiac 9 Cardiac 2/7 Maternal Screening 6 Coagulation 5/17 Serology (EBV) 3 ESR 1 Serology (HIV/Hepatitis) 10 General Clinical Chemistry 10/17/50 Serology (Syphilis) 1 Glycated Haemoglobin 2 Serology (ToRCH) 12 Haematology 11 Specific Proteins 26 Human Urine 25 Therapeutic Drugs 18 Immunoassay 4/13/55 Urinalysis 14 Immunoassay Speciality I 10 Urine Toxicology 20