This presentation describes the operating efficiency improvements and cost savings that users can obtain by applying an Altivar™ 212 AC drive on centrifugal pump and fan applications in place of typical AC drives and the technology designed into the Altivar 212 that provides these additional savings.
Improve Operating Efficiency and Reduce Installed Cost with Altivar™ 212 AC Drives
1. Improve Operating Efficiency and
Reduce Installed Cost with
Altivar 212 and S-Flex Drives
Ivan Spronk
Schneider Electric
Industry NOW Express
2. Altivar® 212 AC Drives with Reduced
Harmonic Technology (RHT)
What is the reduced harmonic technology the Altivar 212 offers?
The Altivar 212 AC drive offer
●A unique optimized power
section
●Powerful motor control
method
●60% reduction in
harmonic currents
(Equivalent signature to
standard Diode Bridge &
Swing Choke)
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 2
3. Altivar® 212 AC Drives with RHT
●AC drive (with line or bus reactor)
100HP example
● Typical 6 pulse AC drive
● With 3% line reactor
● Input voltage: orange
● Input current: cyan
● Lower current spikes due to capacitors charging
● Peak currents = 190 amps
● Harmonic current distortion
● Significant double humped current waveform
contributes to harmonic content.
● THDI = 38% distortion in this example
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 3
4. Altivar® 212 AC Drives with RHT
●Altivar 212 AC Drive
100HP example
● Input voltage: orange
● Input current: cyan
● Low current spikes due to capacitors charging
● Peak currents = 190 amps
● Harmonic current distortion
● Input current is a square shaped waveform.
● Eliminating the large double humped waveform
● Reducing harmonic content
● THDI = 33% in this example
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 4
5. Altivar® 212 AC Drives with RHT
●Altivar 212 output power section
● Output Currents
●Sinusoidal
●Very little distortion
●Due to high speed micro controller
●Due to superior PWM motor control
algorithm
●Completely manages motor protection
●Superior catch-on-the fly algorithm
– Minimize the effect of voltage sags
– Useful for wind-milling fan loads
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012
2012 5
6. Altivar® 212 AC Drives with RHT
Efficiency Comparison Less Capacitance means
Lower Input Amps
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012
2012 6
7. Altivar® 212 AC Drives with RHT
Bottom Line – MORE EFFICIENT !!!!
$$$ Annual Savings $$$
can add up
Averages $10/HP per Year !!
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012
2012 7
8. Altivar® 212 AC Drives with RHT
Benefits of RHT:
● Reduces harmonic distortion
● Reduces enclosure size requirements
● No line reactor or other external filtering
● Reduced capacitance
● Reduces heat dissipation
● No line reactor or other external filtering
● Reduced capacitance
● Improved efficiency
● No losses due to line reactor or other external filtering
● Lower input currents
● Reduces cost of installation
● Save installation time
● Wire size minimized
● Reduces wiring between components
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 8
9. Product Highlights – ATV212(S-Flex)
● Released March 2011, replaced ATV21 F--- : EXTENDED MENU
F100 : Freq. 1 reached
F101 : Freq. 2 reached
● Added Communication Protocols for HVAC
F102 : Freq. 2 bandw.
F108 : Logic Funct. 1active
F109 : VIAselection
Rem Loc/Rem
● (Built-in - Metasys,P1,BacNet,Modbus, option for
LonWorks)
● 1-40 HP 200V, 1-100HP 460V
● Nema 1 and Nema 12 (460V Only)
● 3 Phase VT Fan & Pump ONLY – will not operate on CT
loads
● LED Keypad Standard (low end), Option for LCD mounting
in panel or on S-Flex
● Reduced Harmonic Technology (RHT) built-in with low
capacitance dc bus
● Soon – AC Line Reactor Option where required to provide
per specification.
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 9
10. Altivar 212 Targeted Applications
●Targeted at the following
● Supply and return fans
● Exhaust and ventilation fans
● Cooling tower fans and pumps
● Chiller water and hot water pumps
● Domestic water pumps
● Refrigeration
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 10
11. Altivar 212 Targeted Applications
●Targeted at the following:
● Supply and return fans
● Exhaust and ventilation fans
● Cooling tower fans and pumps
● Chiller water and hot water pumps
● Domestic water pumps
● Refrigeration
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 11
12. Altivar 212
for Building applications
Included building function management
Fire mode
- Motor evacuates smokes with default inhibition
Damper control
- Motor does not start while dampers are not in open
position
Mechanical Protection Function
- Mechanical shock limitation with customized ramp
- Mechanical resonances limitation
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 12
13. Altivar 212
Enclosure : Robust, Compact & Certified
IP20 / UL Type1 IP55 / Type12
IP20
Type 1 conduit available as option
Type 12 available in 460 Vac range
UL 1995 Plenum Rated
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 13
14. Altivar 212: Voltage and HP range
208/230Vac (3 phase input) 1- 40 HP
460Vac (3 phase input) 1- 100 HP 75 to 100 Hp
30 to 60 Hp
20 to 25 Hp
10 to 15 Hp
5 to 7.5 Hp
1 to 3 Hp
Type 12 available in 460 Vac range
Very Small Footprint below 25 HP
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 14
15. Altivar 212
User-friendly
Universal LCD Keypad :
F--- : EXTENDED MENU
F100 : Freq. 1 reached
F101 : Freq. 2 reached - Plain Text clear display
F102 : Freq. 2 bandw. Daisy
F108 : Logic Funct. 1active
F109 : VIA selection
Chain - Structured Menu
Rem Loc/Rem
- 8 Languages (Ch, Sp, It, Fr, Ger, Ru, En, Turkish)
- Fully compatible with other Schneider Electric
drives
- The same part number as ATV 312/32/61/71
- Advanced Menus still have Codes
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 15
16. Altivar 212 : Fan dedicated features
ATV212
Functions Description Location Benefit Parameters
stair well pressurisation Fire Mode
Ensure smoke exhaust
Fire mode inhibiting all default car park ventilation
Security F650-F659
F294
Open or close the Damper Cut-off HVAC in Damper Control
Damper control according to motor run unused area / room
Energy saving
F580-3
Resonance Manage frequency band to
Room ventilation Skip Frequencies
remove fans resonances Comfort
Air distribution
suppression occurs in ventilation system. F270-5
The drive reduces audible occupied rooms in
Noise reduction motor noise building, public area Comfort Noise reduction
Switching frequency
close to people
pre-selected speed enables
Simple system without
Preset speed simple regulation
analogue signal Comfort 8 Preset Speeds
sequence automatically.
Automatically compensate
ventilation distribution, PID Regulator
Flow variation, in order to
Flow compensation follow with high precision
ventilation system, Energy saving
Flow regulation
the system curve
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – October 18, 2012
2012 16
17. ATV212 : Pump dedicated Features
ATV212
Functions Description Location Benefit Parameters
Avoid pump/motor damage
Pump Jam when Jam accumulates into outside pumping, Overload
Open loop pumping Security Over torque
management pump
Pump load Auto adaptation to load
cooling system, water Security
variation, in order to provide PID Regulator
management booster
the pressure or flow reference.
Drive stops the pump when
Sleep/wake detecting low/no flow for preset Chilled Water or Energy saving &
Sleep/Wake up
time, the drive automatically starts Condenser Water pump operating cost
mode
Minimum water The drive provides water supply Alarm detection
HVAC system Security relay+ preset
supply in case of broken pipe or leakage
forced speed
Mechanical shock Avoid mechanical shocks during
Feed water pump, boiler,Acquisition cost Ramps
the start. With a soft start
suppression building cooling system & security S ramp
management, avoid water hammers
Automatically compensate water distribution,
Pressure water supply, Energy saving PID Regulator
pressure variation, follow high
compensation precision of the system curve pressure regulation
pre-selected speed for auto Comfort
Preset speed simple regulation sequence
tank/pipe filling 8 Preset Speeds
of installation
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – October 18, 2012 17
18. The Product Offer
HVAC features
Embedded Solutions
Low Harmonics Emissions : Low THDI = 30%
Cables size saving Limit Capacitor Effects Energy consumption reduction
limit voltage distortion Transformer losses reduction
EMC Immunity Protection
No additional system component (C2/classA)
Comply Building requirement with IEC61000-3-12
Noise reductions : High switch Freq 8khz or 12khz (up to 16khz)
Motor electric noise Mechanical resonance suppression
Audible noise
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 18
19. Altivar® 212 Sales Tools
● Brochure 8800BR1102
● Selection Guide 8800HO1101
● ATV21 to ATV212 Transition Guide
● Guide and Cross Reference file
● 3D CAD Drawings
● PC Soft software
● ATV212 ATV61 Competitors ppt
● iPad and Smart phone Start-up Apps
● (coming soon!)
● ATV212 Customer Presentation
● ATV212 RHT
● Product Data Bulletin 8800DB0702R06/11
● Customer presentation
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – October 18, 2012 19
20. New ATV212 Quick Start Videos
● New Quick Start Videos Release to provide customers visual guides to assist
them in applying ATV212 drives
● Releases on YouTube, iTunes Podcast, and on the Schneider product pages
● Beginning plans to create similar videos for remainder of DT&S Products
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – October 18, 2012 20
21. New ATV212 iPad App
First Select Drive Type and App Main Drive Screen with
will go through Automatic Self ID
Process ALL parameter access
● Engineering has custom cable communicating with drive
● All parameters will be available over the cable and complete configuration files may be
uploaded/downloaded and saved
● Custom configuration files for most commonly accessed parameters are being defined
for Quick Start mode
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – October 18, 2012 21
22. DT&S eTool Development
●1 iPad / Android App deployed
● Energy Savings Calculator
● New Visual Configurator to Include:
● Soft Start Selector
● Variable Torque Drives Selector
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – October 18, 2012 22
23. S-Flex™ 212 Enclosed Drive
S-FlexTM 212 Product Range:
208 Vac 1 - 40 hp
230 Vac 1 - 40 hp
460 Vac 1 - 100 hp
• Four package sizes
• Optional LCD Text Keypad
• Many sizes readily available from
stock
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 23
24. S-Flex 212 Enclosed Drive
What can the S-FlexTM 212 drive do for you?
TM
Square D® brand S-Flex 212 Enclosed Drive provides:
The right features for HVAC pump and fan applications.
Offers unmatched value in installed cost and functionality
Allows building owners, consulting engineers and contractors to
focus on the essentials for commercial building applications.
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 24
25. S-Flex 212 Enclosed Drive
What can the S-FlexTM 212 drive do for you?
TM
S-Flex 212 Enclosed Drive provides energy savings by
reducing motor speed and electricity usage for a quick
return on investment
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 25
26. TM
S-Flex 212 Enclosed Drive
What can the S-FlexTM 212 drive do for you?
Quick installation with
● EZ-M mounting channel for parallel mounting of multiple
drives
● Conduit knock-outs in bottom of enclosure
●Customer control wiring terminal block
Quick start-up with pre-programmed configurations for variable
torque motor applications
● Easy to use
● Reduced time to operation
Stock availability for quick delivery with D07 and B07 Options
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 26
27. What’s new in drives?
● S-Flex Enhancements
New MTE
● ATV212 already the lowest
harmonic generation drive on RLW
the market Reactor
● New AC Line Reactor Option
● Use with standard
harmonic signature of
3% impedance ATV212
● Factory Mounted and
Standard S-
Wired -- 1.5% Flex
Impedance
● Use where specifications - Bypass
require the addition of a
Reactor - Operator
● Remember….. Controls
● Adding Impedance =
Lower Efficiency - Main CB
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 27
28. What’s new in drives?
• S-Flex Enhancement Standard
Bypass now includes:
• True Damper Control circuit
- Kept smoke purge relay
- Added damper control
relay
• Operation
- Close start command
- Closes damper actuator S-Flex ByPass
relay
- Waits for feedback from -- Purge Relay
damper end switch for Fire and
Smoke
- Drive starts
Evacuation
- By-pass starts
- New Damper
Control Relay
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 28
29. New Standards
• AHRI Standard “VFD Performance
Ratings” will level the playing field for
Drive’s
• 3 Certified Tests Required for
compliance
• Drive Efficiency
• Harmonic Distortion
• Motor Output Waveform
• ATV212 Has……
• 3-5% Better Efficiency
• 35% or Lower Harmonic Distortion
• Equivalent dv/dt Motor Output
Schneider Electric - Industry Business – Improving Operating Efficiency and Reduce Installed Cost with Altivar 212 – 2012 29
30. Thank You!