I gave this slideshow presentation on 10/17/09 at the 4th annual North American Passive House Conference in Urbana, IL. It is mostly focused on the "Passive House in the Woods" project.
The slideshow contains a lot of full-screen images but no subtitles, therefore omitting some of the information which would have been given verbally during the presentation.
6. N
1
UP DN
DOWN UP
1 PARK
2 LIVE
5 3 DINE
7 DN
4 COOK
5 ENTER
4 6 POWDER
3
2 6 7 BE
U SE
HO
E s
IV o od
SS he w
PA in t
FIRST FLOOR
7. N
UP
UP 1 STORE, VENTILATE
1 2 HANG OUT
3 MAKE
2 4 BATHE
5 STORE, HEAT WATER
3 4 5
U SE
HO
E s
IV o od
SS he w
PA in t
WALK-OUT
8. N
UP DN
6 DOWN
1 SLEEP
2 STUDY/SLEEP
3 WALK/DRESS
3 5
4 BATHE
1 5 LAUNDER
6 MEDITATE
2 4
U SE
HO
E s
IV o od
SS he w
PA in t
SECOND FLOOR
9. N
1 STAR-GAZE
DN
2
2 ENERGIZE
DN
1
U SE
HO
E s
IV o od
SS he w
PA in t
ROOFTOP TERRACE
10. SCHEDULED BASE
SCHEDULED FLOORING
SCHEDULED 1/4" SELF-LEVELING COMPOUND
WITH ELECTRIC IN-FLOOR HEATING MATS PER MECH. PLAN
3/4 PLYWOOD SUBFLOOR
STO 1.0 / FINE (EIFS)
11-7/8" I-JOIST
11" EPS (EIFS)
3-1/2" RECYCLED COTTON FIBER INSULATION
STO GUARD: AIR TIGHT, DIFFUSION OPEN
3-1/8" INSULATED RIM
5/8" T&G OSB SHEATHING
SEE FIRST FLOOR FRAMING PLAN
FOR CONNECTION
3-1/2" RECYCLED COTTON FIBER INSULATION
(SOUND ATTENUATION)
5/8" WALL BOARD, TYP.
POLY URETHANE GLUE CONNECTION
RESILIENT CHANNEL
AIR-TIGHT SEAL AT SILL
FOAM-PLUG @ SILL PLATE
EARTHEN PLASTER, TYP.
STO FINISH COAT 1/2" WALL BOARD, TYP.
NUDURA ICF (2-5/8" XPS—6" CONC—2-5/8" XPS),
1'-6" THICKNESS OF CONCRETE LAYER PER
STRUCTURAL ENGINEER
STEEL LANDSCAPE
GRADE, MIN. 1/4" PER 1' SLOPE EDGING
2"
GEO-TEXTILE
SCHEDULED BASE
FABRIC
SCHEDULED FLOORING
STO FLEXYL BELOW-GRADE WATER PROOFING
SCHEDULED 1/4" SELF-LEVELING COMPOUND
WITH ELECTRIC IN-FLOOR HEATING MATS
PER MECH. PLAN
4" CONCRETE SLAB (EXPOSED WHERE SCHEDULED)
20 MIL POLY, SEAL JOINTS
GRAVEL BACKFILL
12" XPS INSULATION, DOW SQUARE EDGE, COMPRESSION
STRENGTH PER STRUCTURAL ENGINEER
DRAIN TILE, DRAIN TO DAYLIGHT
COMPACTED SOIL
FTGS, SEE FOUNDATION PLAN
2" XPS INSULATION @ FOOTING, SEAL JOINTS
UNDISTURBED NATIVE SOIL
4 3/8" 11 1/4" 4 3/8"
U SE
HO
E
IV o od
s CONSTRUCTION LINE - OUTSIDE FACE OF ICF
SS he w
PA in t
TYPICAL ASSEMBLY
11. FLASHING
VENTILATION SLOTS
UNDER FLASHING
MIN. 3'-0"
STO 1.0 / FINE (EIFS)
2" EPS INSULATION (EIFS)
WIND WASH BARRIER (EIFS)
PEDESTAL PAVER SYSTEM
5/8" PLYWOOD SHEATHING SLOPE 1/8" PER 1'-0"
CONTINUOUS VENTILATION SPACE,
2X8 @ 24" O.C. FABRIC PROTECTION MAT
2" XPS WITH DRAINAGE CHANNEL
60 MIL REINFORCED EPDM MEMBRANE
WITH STRIPPED-IN SEAMS
3/4" PLYWOOD DECK @
1/4" PER 1'-0" SLOPE
FLAT ROOF FLASHING VENTILATION SPACE
TAPERED FURR FRAMING
USP RT7A TIES @ EACH,
TOP & BTM.
1" EPS INSULATION (EIFS)
2X4 PINCH BLOCK BTWN.
FURR FRAMING. NAIL TO
STUDS & RIM
11-7/8" I-JOIST @ 24" O.C.
2X10 @ 24" O.C. FURR FRAMING, 10d NAIL EACH
INSULATE CAVITIES TIGHTLY
DENSE-PACK CELLULOSE
INSULATION
SEE ROOF FRAMING PLAN
FOR CONNECTION 14" I-JOIST @ 24" O.C.
3-1/8" INSULATED RIM
2X10 PINCH BLOCK STO GUARD,
BTWN. STUDS AIR TIGHT, DIFFUSION OPEN
1/2" EXPANSION JOINT PER STO,
INSULATE CAVITY
ADVANCED FRAMING, 5/8" WALL BOARD
SINGLE PLT. 3/4" FURR FRAMING (INSTALLATION)
5/8" OSB, AIR BARRIER, VAPOR RETARDER
5-1/2" DENSE-PACK CELLULOSE INSULATION,
2X6 FRAMING @ 24" O.C. ADVANCED
STICK FRAMING
SCHEDULED BASE
SCHEDULED FLOORING
SCHEDULED 1/4" SELF-LEVELING COMPOUND
WITH ELECTRIC IN-FLOOR HEATING MATS PER MECH. PLAN
3/4 PLYWOOD SUBFLOOR
11-7/8" I-JOIST
3-1/2" RECYCLED COTTON FIBER INSULATION
3-1/8" INSULATED RIM, R-11
E
US
HO
E s
IV o od
SS he w
PA in t
ADVANCED FRAMING,
SINGLE PLT.
TYPICAL ASSEMBLY
3-1/2" RECYCLED COTTON FIBER INSULATION
(SOUND ATTENUATION)
5/8" WALL BOARD
RESILIENT CHANNEL
5-1/2" DENSE-PACK CELLULOSE INSULATION,
2X6 FRAMING @ 16" O.C. OR ADVANCED
STICK FRAMING
12. R.O.
EXT. ALUM. SILL
EXT. ALUM. SILL
R.O.
INT. WOOD SILL
INT. WOOD SILL
TRACK
TRACK
DC260
DECK CONNECTION?
U SE
HO
E s
IV o od
SS he w
PA in t
TYPICAL WINDOW DETAILS
4:57 PM; TE Studio, Ltd.
13. U SE
HO
E s
IV o od
SS he w
PA in t
VENTILATION - SCHEMATIC
14.
15. DESIGN HEATLOAD
HEATLOAD BASED
RESERVE FACTOR
FOR HEATING (SF)
HEATED SF (W/SF)
AREA AVAILABLE
HEATLOAD WITH
PER HEATED SF
HEATLOAD PER
ENVELOPE (W)
ON HEATLOSS
RESERVE (W)
EXTERIOR
THROUGH
FLOOR
(W/SF)
BSMT 2 337.00 1169.19 2338.37 3.469 6.939
1ST FLR 2 573.00 724.10 1448.20 1.264 2.527
2ND FLR 2 439.00 1217.71 2435.43 2.774 5.548
CHECK 1349.00 3111.00 6222.00
REQ'D AREA OF MAT
MANF. CATALOGUE)
WATTS PER FLOOR
ACTUAL RESERVE
CORRESPONDING
(SELECTED FROM
HEATLOAD WITH
MATT AREA (SF)
(SF AT 12 W/SF)
HEATLOAD (W)
THERMOSTAT
RESERVE (W)
(@ 12 W/SF)
WATTAGE
SIZE (SF)
FLOOR
ROOM
VOLT
AMP
MASTER BEDROOM 177.00 490.97 981.94 81.83 81 972 98% 240 4.1 X
2ND FLR STUDY/ GUEST 120.00 332.86 665.72 55.48 56 672 102% 240 2.8 2469.6 X
2ND FLR BATH 142.00 393.88 787.77 65.65 68.8 825.6 110% 240 3.4 X
LIVING 177.67 224.52 449.03 37.42 39.3 471.6 110% 240 2.0
DINING 177.67 224.52 449.03 37.42 36 432 92% 240 1.8 X
1ST FLR 1515.6
KITCHEN 177.67 224.52 449.03 37.42 36 432 92% 240 1.8
POWDER ROOM 40.00 50.55 101.10 8.42 15 180 256% 240 0.8 X
FAMILY 111.00 385.10 770.21 64.18 64 768 99% 240 3.2
FAMILY 111.00 385.10 770.21 64.18 64 768 99% 240 3.2 X
BASEMENT 2352
HOBBY 68.00 235.92 471.84 39.32 40 480 103% 240 2.0
BATH 47.00 163.06 326.12 27.18 28 336 106% 240 1.4 X
TOTALS 1349.00 3111.00 6222.00 518.50 528.1 6337.2 26.5
U SE
ACTUAL RESERVE WATTAGE 3226.20
HO
S SI
VE o ods
PA in t
w
he
ACTUAL OVERALL RESERVE FACTOR 104%
HEATING SYSTEM
16. U SE
HO
E s
IV o od
SS he w
PA in t
DOMESTIC HOT WATER - SCHEMATIC
17. Utilisation Factor Heat Generator (Project)
Annual Energy Demand, Space Heating 0.0 0.0 0.0
Annual Energy Demand, DHW (without DHW Wash&Dish) 0.0 0.0 0.0
Non-Electric Demand, DHW Wash&Dish (Electricity worksheet) 0.0 0.0 0.0
Non-Electric Demand Cooking/Drying (Gas) (Blatt Strom) 0.0 0.0 0.0
Total - Other 0.0 0.0 0.0
CO2 -Emission Factor (CO2 -
Cooling with Electric Heat Pump PE Value
Equivalent)
kWh/kWh g/kWh
Covered Fraction of Cooling Demand (Project) 100% 2.7 680
Heat Source Electricity
Annual Cooling COP 3.2
Energy Demand Space Cooling 0.3 0.8 0.2
Heating, Cooling, DHW, Auxiliary and Household Electricity 26.8 72.4 18.2
Total PE Value 72.4 kWh/(m!a)
Total Emissions CO2-Equivalent 18.2 kg/(m!a) (Yes/No)
Primary Energy Requirement 120 kWh/(m!a) Yes
Heating, DHW, Auxiliary Electricity (No Household Applications) 17.5 47.3 11.9
Specific PE Demand - Mechanical System 47.3 kWh/(m!a)
Total Emissions CO2-Equivalent 11.9 kg/(m!a)
Solar Electricity kWh/a PE Value (Savings) CO2 -Emission Factor
Planned Annual Electricity Generation Separate Calculation 6500 kWh/kWh g/kWh
0.7 250
Specific Demand 42.5 29.7 10.6
PE Value: Conservation by Solar Electricity 84.9 kWh/(m!a)
CO2 -Emissions Avoided Due to Solar Electricity 18.3 kg/(m!a)
E
HO
U
s
SE
Konk
IV o od
SS he w
PA in t
ENERGY
18. Passive House Verification
Photo or Drawing
Building: Passive House in the Woods
Location and Climate: Town of Hudson, WI Minneapolis TMY3
Street: Kirkwood Way North
Postcode/City: Town of Hudson, WI 54016
Country: USA
Building Type: Single Family Detached
Home Owner(s) / Client(s): Gary Konkol
Street: 1 Kinsman
Postcode/City: Hudson, WI 54016
Architect: Tim Eian/TE Studio, Ltd.
Street: 3429 Benjamin St. NE
Postcode/City: Minneapolis, MN 55418
Mechanical System: TE Studio, Ltd.
Street: 3429 Benjamin St. NE
Postcode/City: Minneapolis, MN 55418
Year of Construction: 2009 0.17
A/V Ratio:
Number of Dwelling Units: 1 Interior Temperature: 20.0 °C
Enclosed Volume Ve: 916.8 m3 Internal Heat Gains: 2.1 W/m2
Number of Occupants: 2.0
Specific Demands with Reference to the Treated Floor Area
Treated Floor Area: 153.1 m2
Applied: Annual Method PH Certificate: Fulfilled?
Specific Space Heat Demand: 14 kWh/(m2 a) 15 kWh/(m2 a) Yes
Annual Heat Demand QH 2208 kWh/a
Pressurization Test Result: 0.6 h-1 0.6 h-1 Yes
Specific Primary Energy Demand
(DHW, Heating, Cooling, Auxiliary and Household Electricity) :
73 kWh/(m2 a) 120 kWh/(m2a) Yes
Specific Primary Energy Demand
(DHW, Heating and Auxiliary Electricity):
48 kWh/(m2 a)
Specific Primary Energy Demand
Energy Conservation by Solar Electricity: 74 kWh/(m2 a)
Heating Load: 20 W/m2
Heating Load PH 3111 W
Frequency of Overheating: 2 % over 25 °C
Specific Useful Cooling Energy Demand: 1 kWh/(m a)2 15 kWh/(m2a) Yes
E
US
E
HO
s
Cooling Load: 7 W/m2
IV o od
SS he w
PA in t
VERIFICATION PAGE
We confirm that the values given herein have been Issued on:
determined following the PHPP methodology and based
on the characteristic values of the building. The calculations signed:
with PHPP are attached to this application.
19. TM
U SE
HO
E s
IV o od
SS he w
PA in t
CERTIFICATION GOALS