SlideShare uma empresa Scribd logo
1 de 12
Baixar para ler offline
We measure it.




VAC measuring
instrument
testo 445 – The service
instrument for ventilation and air
conditioing systems


Point and timed mean value calculation
                                                                             °C

Direct display of the volume flow

Automatic allocation of duct cross-section area to                           %RH

measurement site (max. 99 measurement sites)

Internal measurement value store (3,000 measurement                          m/s

values)

PC software for the analysis, archiving and documentation                    hPa

of the measurement values (option)
                                                                             ppm
Measurement of up to 6 measurement parameters                                CO 2
simultaneously
                                                                             ppm
                                                                             CO
testo 445                                                                                                       We measure it.




Technical data


                                                                       General technical data
 testo 445                                                             Oper. temp.               0 to +50 °C

                                                                       Storage temp.             -20 to +70 °C
 testo 445, VAC measuring instrument, incl.                            Display                   LCD, 4 lines
 TopSafe, battery and calibration protocol
                                                                       Battery type              9V block battery

                                                                       Battery life              45 h

                                                                       PC                        RS232 interface
 Part no. 0560 4450                                                    Weight                    255 g

                                                                       Material/Housing          ABS

                                                                       Warranty                  2 years

                                                                       Memory                    3000

                                                                       Dimensions                215 x 68 x 47 mm

                                                                       Battery life: 6-45 h (depending on probe)
                                                                       Mains conn. and batt. rech. in instr.
                                                                       Calculated humidity parameters: td, g/m3, g/kg pressure-
                                                                       compensated, J/g
                                                                       Calculated volume flow: m3/h (e.g. 0 to 99999 m3/h), m3/min, m3/s,
                                                                       I/s, cfm
                                                                       Calculated velocity values (density-compensated): 0 to 100 m/s; 0 to
                                                                       99999 m3/h
                                                                       Humidity measurement: Measuring range -50 to 180°C; See Probes
                                                                       for accuracy
                                                                       Accuracy of Type K, J: Additional error via operation temperature 0.2
                                                                       °C (adjustment point)




This service instrument is s real multi-talent: the testo 445         At the simple press of a button, the testo 445 displays the
has two probe inputs for the connection of a broad range              last measurment value measured as well as minimum,
of probes for measurements on ventilation/air conditioning            maximum and mean values. In addition to this,
systems. The instrument records flow velocity values in a             measurement data can be stored according to
duct, at a duct outlet or on extraction systems. In addition          measurement site and analyzed on a PC, or documented on
to this, the allrounder measures or calculates the                    site with the Testo fast printer.
parameters volume flow, Indoor Air Quality, temperature,
relative humidity, dewpoint, absolute humidity, degree of
humidity, enthalpy, pressure and CO.




Display of 2 measurement             Simultaneous measurement of up
parameters                           to 6 parameters
testo 445                                                                                                                   We measure it.




Technical data / Accessories


 Sensor type                Meas. range                                 Accuracy ±1 digit                           Resolution

 Type K (NiCr-Ni)           -200 to +1370 °C                            ±0.5% of mv (-200 to 60 °C)                 0.1 °C (-200 to +1370 °C)
                                                                        ±0.5% of mv (+60 to +1370 °C)
                                                                        ±0.3 °C (-60 to +60 °C)
 Type J (Fe-CuNi)           -200 to +1000 °C                            ±0.5% of mv (-200 to 60 °C)                 0.1 °C (-200 to +1000 °C)
                                                                        ±0.5% of mv (+60 to +1000 °C)
                                                                        ±0.3 °C (-60 to +60 °C)
 NTC                        -50 to +150 °C                              ±0.5% of mv (+100 to +150 °C)               0.1 °C (-50 to +150 °C)
                                                                        ±0.2 °C (-25 to +74.9 °C)
                                                                        ±0.4 °C (-50 to -25.1 °C)
                                                                        ±0.4 °C (+75 to +99.9 °C)
 Testo humid. sensor,       0 to +100 %RH                               See probe data                              0.1 %RH (0 to +100 %RH)
 cap.

 Vane                       0 to +60 m/s                                See probe data                              0.01 m/s (0 to +60 m/s)



 Thermal                    0 to +20 m/s                                See probe data                              0.01 m/s (0 to +10 m/s)
                                                                                                                    0.1 m/s (+10.1 to +20 m/s)

 Pressure                   See pressure probes                         ±0.1% of mv                                 0.001 hPa (Sonde 0638 1345)
                                                                                                                    0.001 hPa (Sonde 0638 1445)
                                                                                                                    0.01 hPa (Sonde 0638 1545)
                                                                                                                    1 hPa (Sonde 0638 1645)
 CO2 probe                  0 to +1 Vol. % CO2                          See probe data                              0 Vol. % CO2(0 to +1 Vol. % CO2)



 CO2 probe                  0 to +10000 ppm CO2                         ±(100 ppm CO2 ±3% of mv) (+5000 to          1 ppm CO2 (0 to +10000 ppm CO2)
                                                                        +10000 ppm CO2)
                                                                        ±(500 ppm CO2 ±2% of mv) (0 to
                                                                        +5000 ppm CO2)
 CO probe                   0 to +500 ppm CO                            ±5% of mv (+100 to +500 ppm CO)             1 ppm CO (0 to +500 ppm CO)
                                                                        ±5 ppm CO (0 to +100 ppm CO)




 Transport and Protection                                                                                                           Part no.

 Transport case (plastic) for measuring instrument, probes and accessories                                                        0516 0445
 for safe and orderly storage
 System case (plastic) for measuring instrument, probes and accessories                                                           0516 0400
 probes in lid make it easy to find parts in case (540 x 440 x 130 mm)
 System case (aluminium) for measuring instrument, probes and accessories                                                         0516 0410
 probes in lid make it easy to find parts in case
 TopSafe (indestructible protection case), with bench stand and belt clip                                                         0516 0410



 Printer and Accessories

 Testo fast printer IRDA with wireless infrared interface; 1 roll thermal paper; 4 AA batteries; for printing out                 0554 0549
 measurements on site
 External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries with individual cell charging and charge         0554 0610
 control display, incl. impulse trickle charging, integrated discharge function, with built-in international mains plug, 100-
 240 V, 300 mA, 50/60 Hz
 Spare thermal paper for printer (6 rolls)                                                                                        0554 0569

 Spare thermal paper for printer (6 rolls), permanent ink                                                                         0554 0568
 measurement data documentation legible for up to 10 years


 Software and Accessories

 ComSoft Professional 4 Pro software incl. data archiving                                                                         0554 1704

 RS232 cable connects instrument to PC (1.8 m) for data transfer                                                                  0409 0178
testo 445                                                                                                            We measure it.




Accessories


 Additional accessories and spare parts                                                                                   Part no.

 9V rech. battery for instrument, instead of battery                                                                     0515 0025

 Desk-top power supply with international connection options                                                             0554 1143

 Professional telescopic handle for plug-in vane probes, max. 1 m long                                                   0430 0941

 Handle for plug-in vane probes                                                                                          0430 3545

 Extension cable, 5 m long, between plug-in head cable and instrument, PUR coating material                              0409 0063

 Connection hose; silicone; 5 m long; max. load 700hPa (mbar)                                                            0554 0440

 Cover plugs for test holes (50 off)                                                                                     0554 4001

 Connection hose set, 2 x 1 m, coiled, incl. 1/8" screw connection                                                       0554 0441

 Silicone heat paste (14g), Tmax = +260°C, improves heat transfer in surface probes                                      0554 0004

 Cable, 1.5 m long, connects probe with plug-in head to meas. instrument, PUR coating material                           0430 0143

 Cable, 5 m long, connects probe with plug-in head to measuring instrument, PUR coating material                         0430 0145

 Adapter to connect NiCr-Ni thermocouples and probes with open wire ends                                                 0600 1693

 Control and adjustment set for Testo humidity probes, salt solution with 11.3% RH and 75.3% RH, incl. adapter for       0554 0660
 Testo humidity probes
 Control/adjustment containers (75.3%RH) for 1 point control and adjustment of instrument                                0554 0638

 testo saline solution pot for checking humidity probes, 33 %RH                                                          0554 0636



 Calibration Certificates

 ISO calibration certificate velocity                                                                                    0520 0004
 hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s
 ISO calibration certificate velocity                                                                                    0520 0034
 hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s
 DAkkS calibration certificate velocity                                                                                  0520 0244
 hot wire, vane anemometer; calibration points 0.5; 1; 2; 5; 10 m/s
 DAkkS calibration certificate/velocity                                                                                  0520 0204
 hot wire, vane anemometer, Pitot tube; calibration points 2; 5; 10; 15; 20 m/s
 ISO calibration certificate humidity                                                                                    0520 0006
 Calibration points 11.3 %RH and 75.3 %RH at +25°C
 ISO calibration certificate/humidity                                                                                    0520 0013
 saturated saline solutions: calibration point 11.3%RH
 ISO calibration certificate/humidity                                                                                    0520 0083
 saturated saline solutions, calibration point 75.3%RH
 DAkkS calibration certificate/humidity                                                                                  0520 0206
 electronic hygrometers; calibration points 11.3%RH and 75.3%RH at +25°C
 DAkkS calibration certificate/humidity                                                                                  0520 0213
 saturated saline solutions; calibration point 11.3%RH
 DAkkS calibration certificate/humidity                                                                                  0520 0283
 saturated saline solutions; calibration point 75.3%RH
testo 445                                                                                                                    We measure it.




Probes


 Probe type                            Dimensions                                  Measuring         Accuracy                                     Part no.
                                       Probe shaft/probe shaft tip                 range



 Flow velocity probes

 Vane/temperature probe, Ø 16 mm,                                                  +0.4 to +60 m/s   ±(0.2 m/s +1% of mv) (+0.4 to +40 m/s)      0635 9540
                                                  180 mm                           -30 to +140 °C    ±(0.2 m/s +2% of mv) (+40.1 to +50 m/s)
 attachable to 0430 3545 handle or
 0430 0941 telescopic handle
                                                                     Ø 16 mm


 Vane/temperature probe, Ø 25 mm,                                                  +0.4 to +40 m/s   ±(0.2 m/s ±1% of mv) (+0.4 to +40 m/s)      0635 9640
                                                  180 mm                           -30 to +140 °C
 can be attached to 0430 3545
 handle or 0430 0941 telescopic
 handle                                                              Ø 25 mm

 Bendable vane probe (can be bent                                                  +0.25 to +20      ±(0.1 m/s ±1.5% of mv) (+0.25 to +20 m/s)   0635 9440
                                                                                   m/s
 by 90°), Ø 60 mm, attachable to
 handle 0430 3545 or telescopic                            Ø 60 mm                 Oper. temp.
 handle 0430 0941, for meas. on                                                    0 to +60 °C
 ventilation outlets
 Bendable vane probe (can be bent                                                  +0.1 to +15 m/s   ±(0.1 m/s ±1.5% of mv) (+0.1 to +15 m/s)    0635 9340
 by 90°), Ø 100 mm, attachable to                                                  Oper. temp.
 handle 0430 3545 or telescopic                                         Ø 100 mm   0 to +60 °C
 handle 0430 0941, for
 measurements on ventilation outlets
 Affordable, robust hot bulb probe,                                                0 to +10 m/s      ±(0.03 m/s ±5% of mv) (0 to +10 m/s)        0635 1549
                                                             150 mm                -20 to +70 °C
 Ø 3 mm, for measurements in the
 lower velocity range, with handle
                                                             Ø 4 mm      Ø 3 mm


 Robust hot bulb probe, Ø 3 mm,                                                    0 to +10 m/s      ±(0.03 m/s ±5% of mv) (0 to +10 m/s)        0635 1049
                                                      850 mm                       -20 to +70 °C
 with handle and telescopic handle
 for measurements in the lower
 velocity range                                                          Ø 3 mm


 Quick-action hot wire probe, Ø 10                                                 0 to +20 m/s      ±(0.03 m/s ±4% of mv) (0 to +20 m/s)        0635 1041
                                                      760 mm                       -20 to +70 °C
 mm, with telescopic handle, for
 measurements in the lower velocity
 range with direction recognition                                        Ø 10 mm


 Robust hot bulb probe, Ø 3 mm, for                                                0 to +10 m/s      ±(0.03 m/s ±5% of mv) (0 to +10 m/s)        0628 0035
                                                      150 mm                       -20 to +70 °C
 measurements in the lower velocity
 range, 2m cable (PVC)
                                                      Ø 3 mm


 Thermal anemometer probe, Ø 10                                                    0 to +5 m/s       ±(0.02 m/s ±5% of mv) (0 to +5 m/s)         0635 1047
                                                      760 mm                       0 to +50 °C
 mm, w. telescopic handle,
 measures air flow in lab fume
 cupboards to DIN EN 14175                                               Ø 10 mm


 Vane probe, Ø 16 mm, with                                                         +0.6 to +40 m/s   ±(0.2 m/s ±1.5% of mv) (+0.6 to +40 m/s)    0628 0005
                                                      700 mm
 telescopic handle, Tmax +60°C

                                                                         Ø 16 mm


 High temperature vane probe, Ø 25                                                 +0.6 to +20 m/s   ±(0.3 m/s ±1% of fsv) (+0.6 to +20 m/s)     0635 6045
                                                      560 mm                       -40 to +350 °C
 mm, with handle for continuous
 measurements up to +350°C
                                                                      Ø 25 mm


 testovent 415, volume flow funnel, Ø 210 mm/210x210 mm, incl. case                                                                              0554 0415



 testovent 410, volume flow funnel, Ø 340 mm/330x330 mm, incl. case                                                                              0554 0410
testo 445                                                                                                                We measure it.




Probes


 Probe type                              Dimensions                           Measuring        Accuracy                                    Part no.
                                         Probe shaft/probe shaft tip          range



 Pressure

 Precision pressure probe, 100 Pa,                                            0 to +100 Pa     ±(0.3 Pa ±0.5% of mv) (0 to +100 Pa)       0638 1345
 measures differential pressure and
 velocities (in combination with Pitot
 tube)



 Pressure probe, 10 hPa, measures                                             0 to +10 hPa     ±0.03 hPa (0 to +10 hPa)                   0638 1445
 differential pressure and velocities
 (in combination with Pitot tube)




 Pressure probe, 100 hPa, measures                                            0 to +100 hPa    ±0.5% of mv (+20 to +100 hPa)              0638 1545
                                                                                               ±0.1 hPa (0 to +20 hPa)
 differential pressure and velocities
 (in combination with Pitot tube)




 Pressure probe, 2000 hPa,                                                    0 to +2000 hPa   ±5 hPa (0 to +2000 hPa)                    0638 1645
 measures absolute pressure




 Pressure transmitter 0 to 10 bar, to measure pressure in liquid substances                                                               0554 5254
 (please also order 1/8" adapter 0554 5200 for pressure range up to 7 bar)
testo 445                                                                                       We measure it.




Probes


 Probe type                             Dimensions                             Measuring                          Part no.
                                        Probe shaft/probe shaft tip            range



 Pitot tubes

 Pitot tube, 500 mm long, Ø 7 mm,                                              Oper. temp.                       0635 2045
                                                                               0 to +600 °C
 stainless steel, measures flow                        500 mm
                                                                      Ø 7 mm
 speed


 Pitot tube, 350 mm long, Ø 7 mm,                                              Oper. temp.                       0635 2145
                                                                               0 to +600 °C
 stainless steel, measures flow                        350 mm
                                                                      Ø 7 mm
 speed


 Pitot tube, 300 mm long, Ø 4 mm,                                              Oper. temp.                       0635 2245
                                                                               0 to +600 °C
 stainless steel, measures flow                        300 mm
                                                                      Ø 4 mm
 speed


 Pitot tube, 1000 mm long, stainless                                           Oper. temp.                       0635 2345
                                                                               0 to +600 °C
 steel, measures flow speed                            1000 mm
                                                                      Ø 7 mm




 Pitot tube, stainless steel, 1000 mm                                          Probe type                        0635 2240
                                                                               Type K (NiCr-
 long, measures velocity with                                                  Ni)
 temperature, for pressure probes                                              -40 to +600 °C
 0638 1345/..1445/..1545                               1000 mm        Ø 8 mm




 Pitot tube, stainless steel, 500 mm                                           Probe type                        0635 2140
                                                                               Type K (NiCr-
 long, measures velocity with                                                  Ni)
 temperature, for pressure probes                                              -40 to +600 °C
 0638 1345/..1445/..1545                               500 mm         Ø 8 mm




 Pitot tube, stainless steel, 360 mm                                           Probe type                        0635 2040
                                                                               Type K (NiCr-
 long, measures velocity with                                                  Ni)
 temperature, for pressure probes                                              -40 to +600 °C
 0638 1345/..1445/..1545                               360 mm         Ø 8 mm
testo 445                                                                                                                      We measure it.




Probes


 Probe type                            Dimensions                                   Measuring         Accuracy                          t90      Part no.
                                       Probe shaft/probe shaft tip                  range



 More probes

 3-function probe for simultaneous                                                  0 to +10 m/s      ±(0.03 m/s ±5% of mv)(0 to 10             0635 1540
                                                      270 mm                        0 to +100 %RH     m/s)
 measurement of temperature,                                                        -20 to +70 °C     ±2 %RH (+2 to +98 %RH)
 humidity and velocity. With plug-in                                                                  ±0.4 °C (0 to +50 °C)
 head, 0430 0143 connection cable                                        Ø 21 mm
                                                                                                      ±0.5 °C (remaining range)
 required


 Comfort level probe for measuring                                                  0 to +5 m/s       ±(0.03 m/s ±4% of mv) (0 to +5            0628 0009
                                             890 mm                                 0 to +50 °C       m/s)
 degree of turbulence, with                                                                           ±0.3 °C (0 to +50 °C)
 telescopic handle and stand.                                            Ø 90 mm
 Fulfills EN 13779 requirements

 Ambient CO2 probe, Plug-in head,                                                   0 ... +1 Vol. %   ±(50 ppm CO2 ±2% of mv) (0 to             0632 1240
                                                                                    CO2               +5000 ppm CO2)
 connection cable 0430 0143 or                                                      0 ... +10000      ±(100 ppm CO2 ±3% of mv)
 0430 0145 required                                                                 ppm CO2           (+5001 to +10000 ppm CO2)



 Ambient CO probe, for detecting                                                    0 to +500 ppm     ±5% of mv (+100.1 to +500                 0632 3331
                                                                                    CO                ppm CO)
 CO in buildings and rooms; 0 to                                                                      ±5 ppm CO (0 to +100 ppm CO)
 +500 ppm




 Humidity probes

 Standard ambient air probe up to                                                   0 to +100 %RH     ±2 %RH (+2 to +98 %RH)            12 s    0636 9740
                                                                                    -20 to +70 °C     ±0.4 °C (-10 to +50 °C)
 +70°C, Plug-in head. connection                                                                      ±0.5 °C (remaining range)
 cable 0430 0143 or 0430 0145
 required                                                      Ø 12 mm


 Duct humidity/temperature probe,                                                   0 to +100 %RH     ±2 %RH (+2 to +98 %RH)            12 s    0636 9715
                                                      180 mm                        -20 to +70 °C     ±0.4 °C (-10 to +50 °C)
 Fixed cable 3 m                                                                                      ±0.5 °C (remaining range)

                                                      Ø 12 mm


 Thin humidity probe incl. 4                                                        0 to +100 %RH     ±2 %RH (+2 to +98 %RH)            15 s    0636 2130
                                                      250 mm                        -20 to +70 °C     ±0.4 °C (-10 to +50 °C)
 attachable protection caps for                                                                       ±0.5 °C (-20 to -10.1 °C)
 ambient air measurements,                                                                            ±0.5 °C (+50.1 to +70 °C)
 measurements in exhaust air ducts                    Ø 4 mm
 and equilibrium moisture
 measurements , Plug-in head.
 connection cable 0430 0143 or
 0430 0145 required

 Highly accurate reference                                                          0 to +100 %RH     ±1 %RH (+10 to +90 %RH)*          12 s    0636 9741
                                                                                    -20 to +70 °C     ±2 %RH (remaining range)
 humidity/temp. probe, Plug-in                                                                        ±0.2 °C (+10 to +40 °C)
 head. connection cable 0430 0143                                         Ø 21 mm                     ±0.4 °C (remaining range)
 or 0430 0145 required                                                                                * in the temperature range from
                                                                                                      +15°C to +30°C

 Sword probe for measuring                                                          0 to +100 %RH     ±2 %RH (+2 to +98 %RH)            12 s    0636 0340
                                                      320 mm                        -20 to +70 °C     ±0.4 °C (-10 to +50 °C)
 humidity and temperature in                                                                          ±0.5 °C (-20 to -10.1 °C)
 stacked material, Plug-in head.                                                                      ±0.5 °C (+50.1 to +70 °C)
 connection cable 0430 0143 or                        18 mm x 5 mm
 0430 0145 required


 High humidity level probe w/                                                       0 to +100 %RH     ±2.5   %RH (0 to +100 %RH)        30 s    0636 2142
                                                      300 mm                        -20 to +85 °C     ±0.4   °C (-10 to +50 °C)
 heated sensor element, no humidity                                                                   ±0.5   °C (-20 to -10.1 °C)
 on sensor, Plug-in head.                                                                             ±0.5   °C (+50.1 to +100 °C)
 connection cable 0430 0143 or                        Ø 12 mm
 0430 0145 required
testo 445                                                                                                               We measure it.




Probes


 Probe type                            Dimensions                              Measuring        Accuracy                           t99     Part no.
                                       Probe shaft/probe shaft tip             range



 Humidity probes

 Robust humidity probe e.g. for                                                0 to +100 %RH    ±2 %RH (+2 to +98 %RH)             30 s   0636 2140
                                                      300 mm                   -20 to +120 °C   ±0.4 °C (-10 to +50 °C)
 measuring equilibrium moisture or                                                              ±0.5 °C (remaining range)
 for measurements in exhaust ducts
 to +120°C, Plug-in head.                             Ø 12 mm
 connection cable 0430 0143 or
 0430 0145 required



 Robust high temperature/humidity                                              0 to +100 %RH    ±2 %RH (+2 to +98 %RH)             30 s   0628 0021
                                                      300 mm                   -20 to +180 °C   ±0.4 °C (+0.1 to +50 °C)
 probe up to +180°C , Plug-in head.                                                             ±0.5 °C (remaining range)
 connection cable 0430 0143 or
 0430 0145 required                                   Ø 12 mm


 Flexible humidity probe (does not                                             0 to +100 %RH    ±2 %RH (+2 to +98 %RH)             30 s   0628 0022
                                                      1500 mm   100 mm         -20 to +180 °C   ±0.4 °C (+0.1 to +50 °C)
 retain shape) for measurements in                                                              ±0.5 °C (-20 to 0 °C)
 inaccessible places , Plug-in head.                                                            ±0.5 °C (+50.1 to +180 °C)
 connection cable 0430 0143 or                                  Ø 12 mm
 0430 0145 required
 Standard pressure dewpoint probe                                              0 to +100 %RH    ±0.9 °C tpd (+0.1 to +50 °C tpd)          0636 9840
                                                      300 mm                   -30 to +50 °C    ±1 °C tpd (-4.9 to 0 °C tpd)
 for measurements in compressed                                                tpd              ±2 °C tpd (-9.9 to -5 °C tpd)
 air systems , Plug-in head.                                                                    ±3 °C tpd (-19.9 to -10 °C tpd)
 connection cable 0430 0143 or                                                                  ±4 °C tpd (-30 to -20 °C tpd)
 0430 0145 required
 Precision pressure dewpoint probe                                             0 to +100 %RH    ±0.8 °C tpd (-4.9 to +50 °C tpd)          0636 9841
                                                      300 mm                   -60 to +50 °C    ±1 °C tpd (-9.9 to -5 °C tpd)
 for measurements in compressed                                                tpd              ±2 °C tpd (-19.9 to -10 °C tpd)
 air systems incl. cert. with test                                                              ±3 °C tpd (-29.9 to -20 °C tpd)
 point -40°C tpd, Plug-in head.                                                                 ±4 °C tpd (-40 to -30 °C tpd)
 connection cable 0430 0143 or
 0430 0145 required

 Humidity/temperature probe , Plug-                                            0... +100 %RH    ±2 %RH (+2... +98 %RH)             12 s   0636 9742
                                                                               -20 to +70 °C    ±0.4 °C (+0.1 to +50 °C)
 in head. connection cable 0430                                                                 ±0.5 °C (-20 to 0 °C)
 0143 or 0430 0145 required                                          Ø 21 mm                    ±0.5 °C (+50.1 to +70 °C)




 Probes aw value

 aw value set: pressure-tight                                                  0 to +1 aW       ±0.01 aW (+0.1 to +0.9 aW)                0628 0024
                                                                               0 to +100 %RH    ±0.02 aW (+0.9 to +1 aW)
 precision humidity probe with                                                 -20 to +70 °C    ±1 %RH (+10 to +90 %RH)
 certificate, measurement chamber                                                               ±2 %RH (0 to +10 %RH)
 and 5 sample bowls (plastic),                                                                  ±2 %RH (+90 to +100 %RH)
                                                                                                ±0.4 °C (-10 to +50 °C)
 Reproducibility of aw value ±0.003                                                             ±0.5 °C (remaining range)
testo 445                                                                                                                            We measure it.




Probes


 Probe type                                      Dimensions                                           Measuring         Accuracy           t99         Part no.
                                                 Probe shaft/probe shaft tip                          range



 Type K (NiCr-Ni)

 Quick-action surface probe, Plug-in                                                                  -200 to +300 °C   Class 2 1)         3s         0604 0194
                                                                      150 mm
 head. connection cable 0430 0143
 or 0430 0145 required
                                                                                       Ø 10 mm


 Super quick-action                                                                                   -200 to +600 °C   Class 1 1)         1s         0604 0493
                                                                      150 mm
 immersion/penetration probe for
 measurements in liquids , Plug-in
 head. connection cable 0430 0143                                     Ø 1.5 mm
 or 0430 0145 required
 Super quick-action                                                                                   -200 to +600 °C   Class 1 1)         1s         0604 9794
                                                                      150 mm           20 mm
 immersion/penetration probe for
 measurements in gases and liquids
 with a low-mass tip, Plug-in head.                                   Ø 1.4 mm         Ø 0.5 mm
 connection cable 0430 0143 or
 0430 0145 required

 Robust surface probe , Plug-in                                                                       -200 to +600 °C   Class 1 1)         25 s       0604 9993
                                                                      150 mm
 head. connection cable 0430 0143
 or 0430 0145 required                                                                   Ø 4 mm




 Fast response                                                                                        -200 to +400 °C   Class 1 1)         3s         0604 0293
                                                                      150 mm
 immersion/penetration probe ,
 Plug-in head. connection cable
 0430 0143 or 0430 0145 required                                      Ø 3 mm


 Super quick-action                                                                                   -200 to           Class 1 1)         1s         0604 0593
                                                                      470 mm                          +1100 °C
 immersion/penetration probe for
 high temperatures , Plug-in head.
 connection cable 0430 0143 or                                        Ø 1.5 mm
 0430 0145 required
 Spare meas. head for pipe wrap                          35 mm                                        -60 to +130 °C    Class 2 1)         5s         0602 0092
 probe, TC Type K
                                                                    15 mm



 Plug-in measuring tip, 750mm long,                                                                   -200 to +900 °C   Class 1 1)         4s         0600 5393
                                                                      750 mm
 flexible, for high temperatures,
 outer casing: stainless steel 1.4541
 . Please order handle with Part no.                                  Ø 3 mm
 0600 5593


 Plug-in measuring tip, 1200 mm                                                                       -200 to +900 °C   Class 1 1)         4s         0600 5493
                                                                      1200 mm
 long, flexible, for high
 temperatures, outer casing:
 stainless steel 1.4541 . Please                                      Ø 3 mm
 order handle with Part no. 0600
 5593

 Plug-in measuring tip, 550mm long,                                                                   -200 to           Class 1 1)         4s         0600 5793
                                                                      550 mm                          +1100 °C
 flexible, for high temperatures,
 outer casing: Inconel 2.4816 .
 Please order handle with Part no.                                    Ø 3 mm
 0600 5593


 Plug-in measuring tip, 1030mm                                                                        -200 to           Class 1 1)         4s         0600 5893
                                                                      1030 mm                         +1100 °C
 long, flexible, for high
 temperatures, outer casing: Inconel
 2.4816 . Please order handle with                                    Ø 3 mm
 Part no. 0600 5593


 1) According to standard EN 60584-2, the accuracy of Classes 1 / 2 refer to -40 to +1000/+1200 °C.
testo 445                                                                                                    We measure it.




Covering caps


                                                                           Abbildung             For humidity probes              Part no.




 Caps for humidity probes Ø 12m and 21mm

 Metal protection cage, Ø 12 mm for humidity probes, for measurement in                          0636 9740, 0636 9715            0554 0755
 flow velocities of less than 10 m/s
                                                                                       Ø 12 mm




 Cap with wire mesh filter, Ø 12 mm                                                              All humidity probes with Ø 12   0554 0757
                                                                                                 mm




 PTFE sintered filter, Ø 21 mm, for corrosive substances, high humidity                          All humidity probes with Ø 21   0554 0666
                                                                                                 mm
 range (long-term measurements), high velocities
                                                                                       Ø 21 mm




 Sintered PTFE filter, Ø 12 mm, for corrosive media, High humidity range                         0636 9769, 0636 9740, 0636      0554 0756
                                                                                                 9715
 (long-term measurements), high flow velocities.
                                                                                       Ø 12 mm




 PTFE sintered filter, Ø 12 mm, for corrosive substances, high humidity                          0628 0021, 0628 0022, 0636      0554 0758
                                                                                                 2140, 0636 2142
 range (non-stop measurements), high flow speeds
                                                                                       Ø 12 mm




 Stainless steel sintered cap, Ø 21 mm, can be screwed onto humidity                             All humidity probes Ø 21 mm     0554 0640
 probe, protection in case of high mechanical load and high velocities
                                                                                       Ø 21 mm




 Stainless steel sintered cap, Ø 12 mm, is screwed onto humidity probe,                          0636 9740, 0636 9715            0554 0647
 for measurements at higher flow velocities or in contaminated air
                                                                                       Ø 12 mm




 PTFE cap, Ø 5 mm, attachable, PTFE material, (5 off) PTFE, Dust                                 0636 2130                       0554 1031
 protection, high humidity measurements, high velocities
                                                                                       Ø 5 mm
testo 445




www.testo.co.uk
                                                              We measure it.




Subject to change without notice.   0981 9714/msp/A/01.2012

Mais conteúdo relacionado

Mais procurados

Testo 327 datasheet 2012
Testo 327 datasheet 2012Testo 327 datasheet 2012
Testo 327 datasheet 2012Testo Limited
 
Testo 845 datasheet 2012
Testo 845 datasheet 2012Testo 845 datasheet 2012
Testo 845 datasheet 2012Testo Limited
 
Testo 925 datasheet 2012
Testo 925 datasheet 2012Testo 925 datasheet 2012
Testo 925 datasheet 2012Testo Limited
 
Testo 316 4 datasheet 2012
Testo 316 4 datasheet 2012Testo 316 4 datasheet 2012
Testo 316 4 datasheet 2012Testo Limited
 
Testo 314 datasheet 2012
Testo 314 datasheet 2012Testo 314 datasheet 2012
Testo 314 datasheet 2012Testo Limited
 
Testo 360 datasheet 2012
Testo 360 datasheet 2012Testo 360 datasheet 2012
Testo 360 datasheet 2012Testo Limited
 
Testo 340 flue gas analyser datasheet
Testo 340 flue gas analyser datasheetTesto 340 flue gas analyser datasheet
Testo 340 flue gas analyser datasheetTesto Limited
 
Hướng dẫn sử dụng máy đo hạt bụi Testo 380
Hướng dẫn sử dụng máy đo hạt bụi Testo 380Hướng dẫn sử dụng máy đo hạt bụi Testo 380
Hướng dẫn sử dụng máy đo hạt bụi Testo 380Tenmars Việt Nam
 
Thermohygrometers
ThermohygrometersThermohygrometers
Thermohygrometerslink2013
 
Analisis de harinas dumas
Analisis de harinas dumasAnalisis de harinas dumas
Analisis de harinas dumasEDGARDO QUINDE
 
MG 2030 CEM Datasheet
MG 2030 CEM DatasheetMG 2030 CEM Datasheet
MG 2030 CEM Datasheetjimbelanger33
 
Lighthouse Overview Presentation Linkedin2
Lighthouse Overview Presentation Linkedin2Lighthouse Overview Presentation Linkedin2
Lighthouse Overview Presentation Linkedin2golighthouse
 
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas AnalyzerMRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas AnalyzerDiamond Scientific
 
SWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas AnalyzerSWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas AnalyzerDiamond Scientific
 
Vaisala webinar - Common pitfalls in industrial humidity measurements
Vaisala webinar - Common pitfalls in industrial humidity measurementsVaisala webinar - Common pitfalls in industrial humidity measurements
Vaisala webinar - Common pitfalls in industrial humidity measurementsVaisala Group
 

Mais procurados (20)

Testo 327 datasheet 2012
Testo 327 datasheet 2012Testo 327 datasheet 2012
Testo 327 datasheet 2012
 
Testo 845 datasheet 2012
Testo 845 datasheet 2012Testo 845 datasheet 2012
Testo 845 datasheet 2012
 
Testo 925 datasheet 2012
Testo 925 datasheet 2012Testo 925 datasheet 2012
Testo 925 datasheet 2012
 
Testo 316 4 datasheet 2012
Testo 316 4 datasheet 2012Testo 316 4 datasheet 2012
Testo 316 4 datasheet 2012
 
Testo 314 datasheet 2012
Testo 314 datasheet 2012Testo 314 datasheet 2012
Testo 314 datasheet 2012
 
Testo 360 datasheet 2012
Testo 360 datasheet 2012Testo 360 datasheet 2012
Testo 360 datasheet 2012
 
Testo 340 flue gas analyser datasheet
Testo 340 flue gas analyser datasheetTesto 340 flue gas analyser datasheet
Testo 340 flue gas analyser datasheet
 
Hướng dẫn sử dụng máy đo hạt bụi Testo 380
Hướng dẫn sử dụng máy đo hạt bụi Testo 380Hướng dẫn sử dụng máy đo hạt bụi Testo 380
Hướng dẫn sử dụng máy đo hạt bụi Testo 380
 
Mixed Gas Permeability Analyzer
Mixed Gas Permeability AnalyzerMixed Gas Permeability Analyzer
Mixed Gas Permeability Analyzer
 
Practical concerns in ega
Practical concerns in egaPractical concerns in ega
Practical concerns in ega
 
Testo 330
Testo 330Testo 330
Testo 330
 
G2/110 Separation Membrane Permeability Analyzer
G2/110 Separation Membrane Permeability AnalyzerG2/110 Separation Membrane Permeability Analyzer
G2/110 Separation Membrane Permeability Analyzer
 
Thermohygrometers
ThermohygrometersThermohygrometers
Thermohygrometers
 
Analisis de harinas dumas
Analisis de harinas dumasAnalisis de harinas dumas
Analisis de harinas dumas
 
MG 2030 CEM Datasheet
MG 2030 CEM DatasheetMG 2030 CEM Datasheet
MG 2030 CEM Datasheet
 
Lighthouse Overview Presentation Linkedin2
Lighthouse Overview Presentation Linkedin2Lighthouse Overview Presentation Linkedin2
Lighthouse Overview Presentation Linkedin2
 
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas AnalyzerMRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
 
En20110403 3-4
En20110403 3-4En20110403 3-4
En20110403 3-4
 
SWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas AnalyzerSWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas Analyzer
 
Vaisala webinar - Common pitfalls in industrial humidity measurements
Vaisala webinar - Common pitfalls in industrial humidity measurementsVaisala webinar - Common pitfalls in industrial humidity measurements
Vaisala webinar - Common pitfalls in industrial humidity measurements
 

Destaque

Testo - Multifunction Measuring Instruments
Testo - Multifunction Measuring InstrumentsTesto - Multifunction Measuring Instruments
Testo - Multifunction Measuring InstrumentsTesto Limited
 
Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014Testo Limited
 
Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014Testo Limited
 
Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014Testo Limited
 
Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014Testo Limited
 
Cloud based monitoring
Cloud based monitoringCloud based monitoring
Cloud based monitoringTesto Limited
 
Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014Testo Limited
 
Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014Testo Limited
 
Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014Testo Limited
 

Destaque (9)

Testo - Multifunction Measuring Instruments
Testo - Multifunction Measuring InstrumentsTesto - Multifunction Measuring Instruments
Testo - Multifunction Measuring Instruments
 
Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014
 
Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014
 
Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014
 
Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014
 
Cloud based monitoring
Cloud based monitoringCloud based monitoring
Cloud based monitoring
 
Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014
 
Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014
 
Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014
 

Semelhante a Testo 445 datasheet 2012

Testo 922 datasheet 2012
Testo 922 datasheet 2012Testo 922 datasheet 2012
Testo 922 datasheet 2012Testo Limited
 
Testo 810 datasheet 2012
Testo 810 datasheet 2012Testo 810 datasheet 2012
Testo 810 datasheet 2012Testo Limited
 
Testo huminator datasheet 2012
Testo huminator datasheet 2012Testo huminator datasheet 2012
Testo huminator datasheet 2012Testo Limited
 
Testo 535 datasheet 2012
Testo 535 datasheet 2012Testo 535 datasheet 2012
Testo 535 datasheet 2012Testo Limited
 
Testo 512 datasheet 2012
Testo 512 datasheet 2012Testo 512 datasheet 2012
Testo 512 datasheet 2012Testo Limited
 
Testo 605 datasheet 2012
Testo 605 datasheet 2012Testo 605 datasheet 2012
Testo 605 datasheet 2012Testo Limited
 
Testo 176 p1 datasheet
Testo 176 p1 datasheetTesto 176 p1 datasheet
Testo 176 p1 datasheetTesto Limited
 
Testo 417 datasheet 2012
Testo 417 datasheet 2012Testo 417 datasheet 2012
Testo 417 datasheet 2012Testo Limited
 
Testo 610 datasheet 2012
Testo 610 datasheet 2012Testo 610 datasheet 2012
Testo 610 datasheet 2012Testo Limited
 
Testo 926 datasheet 2012
Testo 926 datasheet 2012Testo 926 datasheet 2012
Testo 926 datasheet 2012Testo Limited
 
Testo 905 datasheet 2012
Testo 905 datasheet 2012Testo 905 datasheet 2012
Testo 905 datasheet 2012Testo Limited
 
Testo 625 datasheet 2012
Testo 625 datasheet 2012Testo 625 datasheet 2012
Testo 625 datasheet 2012Testo Limited
 
Testo 511 datasheet 2012
Testo 511 datasheet 2012Testo 511 datasheet 2012
Testo 511 datasheet 2012Testo Limited
 
Testo 465 datasheet 2012
Testo 465 datasheet 2012Testo 465 datasheet 2012
Testo 465 datasheet 2012Testo Limited
 
Testo 623 datasheet 2012
Testo 623 datasheet 2012Testo 623 datasheet 2012
Testo 623 datasheet 2012Testo Limited
 
Testo 112 datasheet 2012
Testo 112 datasheet 2012Testo 112 datasheet 2012
Testo 112 datasheet 2012Testo Limited
 
Kimo 200 HRS Thermo Hygrometer Datasheet
Kimo 200 HRS Thermo Hygrometer DatasheetKimo 200 HRS Thermo Hygrometer Datasheet
Kimo 200 HRS Thermo Hygrometer Datasheetdarrellwattswif
 
Testo 510 datasheet 2012
Testo 510 datasheet 2012Testo 510 datasheet 2012
Testo 510 datasheet 2012Testo Limited
 

Semelhante a Testo 445 datasheet 2012 (20)

Testo 922 datasheet 2012
Testo 922 datasheet 2012Testo 922 datasheet 2012
Testo 922 datasheet 2012
 
Testo 810 datasheet 2012
Testo 810 datasheet 2012Testo 810 datasheet 2012
Testo 810 datasheet 2012
 
Testo huminator datasheet 2012
Testo huminator datasheet 2012Testo huminator datasheet 2012
Testo huminator datasheet 2012
 
Testo 535 datasheet 2012
Testo 535 datasheet 2012Testo 535 datasheet 2012
Testo 535 datasheet 2012
 
Testo 512 datasheet 2012
Testo 512 datasheet 2012Testo 512 datasheet 2012
Testo 512 datasheet 2012
 
Testo 605 datasheet 2012
Testo 605 datasheet 2012Testo 605 datasheet 2012
Testo 605 datasheet 2012
 
Testo 176 p1 datasheet
Testo 176 p1 datasheetTesto 176 p1 datasheet
Testo 176 p1 datasheet
 
Testo 417 datasheet 2012
Testo 417 datasheet 2012Testo 417 datasheet 2012
Testo 417 datasheet 2012
 
Testo 610 datasheet 2012
Testo 610 datasheet 2012Testo 610 datasheet 2012
Testo 610 datasheet 2012
 
Testo 926 datasheet 2012
Testo 926 datasheet 2012Testo 926 datasheet 2012
Testo 926 datasheet 2012
 
Testo 905 datasheet 2012
Testo 905 datasheet 2012Testo 905 datasheet 2012
Testo 905 datasheet 2012
 
Testo 625 datasheet 2012
Testo 625 datasheet 2012Testo 625 datasheet 2012
Testo 625 datasheet 2012
 
Testo 511 datasheet 2012
Testo 511 datasheet 2012Testo 511 datasheet 2012
Testo 511 datasheet 2012
 
Testo 270 datasheet
Testo 270 datasheetTesto 270 datasheet
Testo 270 datasheet
 
Testo 465 datasheet 2012
Testo 465 datasheet 2012Testo 465 datasheet 2012
Testo 465 datasheet 2012
 
Testo 623 datasheet 2012
Testo 623 datasheet 2012Testo 623 datasheet 2012
Testo 623 datasheet 2012
 
Testo 112 datasheet 2012
Testo 112 datasheet 2012Testo 112 datasheet 2012
Testo 112 datasheet 2012
 
Kimo 200 HRS Thermo Hygrometer Datasheet
Kimo 200 HRS Thermo Hygrometer DatasheetKimo 200 HRS Thermo Hygrometer Datasheet
Kimo 200 HRS Thermo Hygrometer Datasheet
 
Testo 510 datasheet 2012
Testo 510 datasheet 2012Testo 510 datasheet 2012
Testo 510 datasheet 2012
 
Testo 720 datasheet
Testo 720 datasheetTesto 720 datasheet
Testo 720 datasheet
 

Mais de Testo Limited

Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014Testo Limited
 
Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014Testo Limited
 
Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014Testo Limited
 
Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014Testo Limited
 
Testo (PWE) Jan 2014
Testo (PWE) Jan 2014Testo (PWE) Jan 2014
Testo (PWE) Jan 2014Testo Limited
 
Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014Testo Limited
 
Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014Testo Limited
 
Testo (mepca) Jan 2014
Testo (mepca) Jan 2014Testo (mepca) Jan 2014
Testo (mepca) Jan 2014Testo Limited
 
Testo (meat management) Jan 2014
Testo (meat management) Jan 2014Testo (meat management) Jan 2014
Testo (meat management) Jan 2014Testo Limited
 
Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014Testo Limited
 
Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014Testo Limited
 
Testo (installer) Jan 2014
Testo (installer) Jan 2014Testo (installer) Jan 2014
Testo (installer) Jan 2014Testo Limited
 
Testo (hvr) Jan 2014
Testo (hvr) Jan 2014Testo (hvr) Jan 2014
Testo (hvr) Jan 2014Testo Limited
 
Testo (hvp) Jan 2014
Testo (hvp) Jan 2014Testo (hvp) Jan 2014
Testo (hvp) Jan 2014Testo Limited
 
Testo (haccp international) Jan 2014
Testo (haccp international) Jan 2014Testo (haccp international) Jan 2014
Testo (haccp international) Jan 2014Testo Limited
 
Testo (food management today) Jan 2014
Testo (food management today) Jan 2014Testo (food management today) Jan 2014
Testo (food management today) Jan 2014Testo Limited
 
Testo (electrical sourcing) Jan 2014
Testo (electrical sourcing) Jan 2014Testo (electrical sourcing) Jan 2014
Testo (electrical sourcing) Jan 2014Testo Limited
 
Testo (cesa buyers guide) Jan 2014
Testo (cesa buyers guide) Jan 2014Testo (cesa buyers guide) Jan 2014
Testo (cesa buyers guide) Jan 2014Testo Limited
 
Testo (acr today) Jan 2014
Testo (acr today) Jan 2014Testo (acr today) Jan 2014
Testo (acr today) Jan 2014Testo Limited
 
Testo (acr news) Jan 2014
Testo (acr news) Jan 2014Testo (acr news) Jan 2014
Testo (acr news) Jan 2014Testo Limited
 

Mais de Testo Limited (20)

Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014
 
Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014
 
Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014
 
Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014
 
Testo (PWE) Jan 2014
Testo (PWE) Jan 2014Testo (PWE) Jan 2014
Testo (PWE) Jan 2014
 
Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014
 
Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014
 
Testo (mepca) Jan 2014
Testo (mepca) Jan 2014Testo (mepca) Jan 2014
Testo (mepca) Jan 2014
 
Testo (meat management) Jan 2014
Testo (meat management) Jan 2014Testo (meat management) Jan 2014
Testo (meat management) Jan 2014
 
Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014
 
Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014
 
Testo (installer) Jan 2014
Testo (installer) Jan 2014Testo (installer) Jan 2014
Testo (installer) Jan 2014
 
Testo (hvr) Jan 2014
Testo (hvr) Jan 2014Testo (hvr) Jan 2014
Testo (hvr) Jan 2014
 
Testo (hvp) Jan 2014
Testo (hvp) Jan 2014Testo (hvp) Jan 2014
Testo (hvp) Jan 2014
 
Testo (haccp international) Jan 2014
Testo (haccp international) Jan 2014Testo (haccp international) Jan 2014
Testo (haccp international) Jan 2014
 
Testo (food management today) Jan 2014
Testo (food management today) Jan 2014Testo (food management today) Jan 2014
Testo (food management today) Jan 2014
 
Testo (electrical sourcing) Jan 2014
Testo (electrical sourcing) Jan 2014Testo (electrical sourcing) Jan 2014
Testo (electrical sourcing) Jan 2014
 
Testo (cesa buyers guide) Jan 2014
Testo (cesa buyers guide) Jan 2014Testo (cesa buyers guide) Jan 2014
Testo (cesa buyers guide) Jan 2014
 
Testo (acr today) Jan 2014
Testo (acr today) Jan 2014Testo (acr today) Jan 2014
Testo (acr today) Jan 2014
 
Testo (acr news) Jan 2014
Testo (acr news) Jan 2014Testo (acr news) Jan 2014
Testo (acr news) Jan 2014
 

Último

Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherRemote DBA Services
 
Cyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfCyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfOverkill Security
 
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...Zilliz
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsNanddeep Nachan
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...DianaGray10
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...apidays
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDropbox
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...Zilliz
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistandanishmna97
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Victor Rentea
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWERMadyBayot
 
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Jeffrey Haguewood
 
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKSpring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKJago de Vreede
 
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...apidays
 
Corporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptxCorporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptxRustici Software
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc
 
Exploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusExploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusZilliz
 
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Angeliki Cooney
 

Último (20)

Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Cyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfCyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdf
 
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectors
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor Presentation
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
 
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
 
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKSpring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
 
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
 
Corporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptxCorporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptx
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
Exploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusExploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with Milvus
 
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
 

Testo 445 datasheet 2012

  • 1. We measure it. VAC measuring instrument testo 445 – The service instrument for ventilation and air conditioing systems Point and timed mean value calculation °C Direct display of the volume flow Automatic allocation of duct cross-section area to %RH measurement site (max. 99 measurement sites) Internal measurement value store (3,000 measurement m/s values) PC software for the analysis, archiving and documentation hPa of the measurement values (option) ppm Measurement of up to 6 measurement parameters CO 2 simultaneously ppm CO
  • 2. testo 445 We measure it. Technical data General technical data testo 445 Oper. temp. 0 to +50 °C Storage temp. -20 to +70 °C testo 445, VAC measuring instrument, incl. Display LCD, 4 lines TopSafe, battery and calibration protocol Battery type 9V block battery Battery life 45 h PC RS232 interface Part no. 0560 4450 Weight 255 g Material/Housing ABS Warranty 2 years Memory 3000 Dimensions 215 x 68 x 47 mm Battery life: 6-45 h (depending on probe) Mains conn. and batt. rech. in instr. Calculated humidity parameters: td, g/m3, g/kg pressure- compensated, J/g Calculated volume flow: m3/h (e.g. 0 to 99999 m3/h), m3/min, m3/s, I/s, cfm Calculated velocity values (density-compensated): 0 to 100 m/s; 0 to 99999 m3/h Humidity measurement: Measuring range -50 to 180°C; See Probes for accuracy Accuracy of Type K, J: Additional error via operation temperature 0.2 °C (adjustment point) This service instrument is s real multi-talent: the testo 445 At the simple press of a button, the testo 445 displays the has two probe inputs for the connection of a broad range last measurment value measured as well as minimum, of probes for measurements on ventilation/air conditioning maximum and mean values. In addition to this, systems. The instrument records flow velocity values in a measurement data can be stored according to duct, at a duct outlet or on extraction systems. In addition measurement site and analyzed on a PC, or documented on to this, the allrounder measures or calculates the site with the Testo fast printer. parameters volume flow, Indoor Air Quality, temperature, relative humidity, dewpoint, absolute humidity, degree of humidity, enthalpy, pressure and CO. Display of 2 measurement Simultaneous measurement of up parameters to 6 parameters
  • 3. testo 445 We measure it. Technical data / Accessories Sensor type Meas. range Accuracy ±1 digit Resolution Type K (NiCr-Ni) -200 to +1370 °C ±0.5% of mv (-200 to 60 °C) 0.1 °C (-200 to +1370 °C) ±0.5% of mv (+60 to +1370 °C) ±0.3 °C (-60 to +60 °C) Type J (Fe-CuNi) -200 to +1000 °C ±0.5% of mv (-200 to 60 °C) 0.1 °C (-200 to +1000 °C) ±0.5% of mv (+60 to +1000 °C) ±0.3 °C (-60 to +60 °C) NTC -50 to +150 °C ±0.5% of mv (+100 to +150 °C) 0.1 °C (-50 to +150 °C) ±0.2 °C (-25 to +74.9 °C) ±0.4 °C (-50 to -25.1 °C) ±0.4 °C (+75 to +99.9 °C) Testo humid. sensor, 0 to +100 %RH See probe data 0.1 %RH (0 to +100 %RH) cap. Vane 0 to +60 m/s See probe data 0.01 m/s (0 to +60 m/s) Thermal 0 to +20 m/s See probe data 0.01 m/s (0 to +10 m/s) 0.1 m/s (+10.1 to +20 m/s) Pressure See pressure probes ±0.1% of mv 0.001 hPa (Sonde 0638 1345) 0.001 hPa (Sonde 0638 1445) 0.01 hPa (Sonde 0638 1545) 1 hPa (Sonde 0638 1645) CO2 probe 0 to +1 Vol. % CO2 See probe data 0 Vol. % CO2(0 to +1 Vol. % CO2) CO2 probe 0 to +10000 ppm CO2 ±(100 ppm CO2 ±3% of mv) (+5000 to 1 ppm CO2 (0 to +10000 ppm CO2) +10000 ppm CO2) ±(500 ppm CO2 ±2% of mv) (0 to +5000 ppm CO2) CO probe 0 to +500 ppm CO ±5% of mv (+100 to +500 ppm CO) 1 ppm CO (0 to +500 ppm CO) ±5 ppm CO (0 to +100 ppm CO) Transport and Protection Part no. Transport case (plastic) for measuring instrument, probes and accessories 0516 0445 for safe and orderly storage System case (plastic) for measuring instrument, probes and accessories 0516 0400 probes in lid make it easy to find parts in case (540 x 440 x 130 mm) System case (aluminium) for measuring instrument, probes and accessories 0516 0410 probes in lid make it easy to find parts in case TopSafe (indestructible protection case), with bench stand and belt clip 0516 0410 Printer and Accessories Testo fast printer IRDA with wireless infrared interface; 1 roll thermal paper; 4 AA batteries; for printing out 0554 0549 measurements on site External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries with individual cell charging and charge 0554 0610 control display, incl. impulse trickle charging, integrated discharge function, with built-in international mains plug, 100- 240 V, 300 mA, 50/60 Hz Spare thermal paper for printer (6 rolls) 0554 0569 Spare thermal paper for printer (6 rolls), permanent ink 0554 0568 measurement data documentation legible for up to 10 years Software and Accessories ComSoft Professional 4 Pro software incl. data archiving 0554 1704 RS232 cable connects instrument to PC (1.8 m) for data transfer 0409 0178
  • 4. testo 445 We measure it. Accessories Additional accessories and spare parts Part no. 9V rech. battery for instrument, instead of battery 0515 0025 Desk-top power supply with international connection options 0554 1143 Professional telescopic handle for plug-in vane probes, max. 1 m long 0430 0941 Handle for plug-in vane probes 0430 3545 Extension cable, 5 m long, between plug-in head cable and instrument, PUR coating material 0409 0063 Connection hose; silicone; 5 m long; max. load 700hPa (mbar) 0554 0440 Cover plugs for test holes (50 off) 0554 4001 Connection hose set, 2 x 1 m, coiled, incl. 1/8" screw connection 0554 0441 Silicone heat paste (14g), Tmax = +260°C, improves heat transfer in surface probes 0554 0004 Cable, 1.5 m long, connects probe with plug-in head to meas. instrument, PUR coating material 0430 0143 Cable, 5 m long, connects probe with plug-in head to measuring instrument, PUR coating material 0430 0145 Adapter to connect NiCr-Ni thermocouples and probes with open wire ends 0600 1693 Control and adjustment set for Testo humidity probes, salt solution with 11.3% RH and 75.3% RH, incl. adapter for 0554 0660 Testo humidity probes Control/adjustment containers (75.3%RH) for 1 point control and adjustment of instrument 0554 0638 testo saline solution pot for checking humidity probes, 33 %RH 0554 0636 Calibration Certificates ISO calibration certificate velocity 0520 0004 hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s ISO calibration certificate velocity 0520 0034 hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s DAkkS calibration certificate velocity 0520 0244 hot wire, vane anemometer; calibration points 0.5; 1; 2; 5; 10 m/s DAkkS calibration certificate/velocity 0520 0204 hot wire, vane anemometer, Pitot tube; calibration points 2; 5; 10; 15; 20 m/s ISO calibration certificate humidity 0520 0006 Calibration points 11.3 %RH and 75.3 %RH at +25°C ISO calibration certificate/humidity 0520 0013 saturated saline solutions: calibration point 11.3%RH ISO calibration certificate/humidity 0520 0083 saturated saline solutions, calibration point 75.3%RH DAkkS calibration certificate/humidity 0520 0206 electronic hygrometers; calibration points 11.3%RH and 75.3%RH at +25°C DAkkS calibration certificate/humidity 0520 0213 saturated saline solutions; calibration point 11.3%RH DAkkS calibration certificate/humidity 0520 0283 saturated saline solutions; calibration point 75.3%RH
  • 5. testo 445 We measure it. Probes Probe type Dimensions Measuring Accuracy Part no. Probe shaft/probe shaft tip range Flow velocity probes Vane/temperature probe, Ø 16 mm, +0.4 to +60 m/s ±(0.2 m/s +1% of mv) (+0.4 to +40 m/s) 0635 9540 180 mm -30 to +140 °C ±(0.2 m/s +2% of mv) (+40.1 to +50 m/s) attachable to 0430 3545 handle or 0430 0941 telescopic handle Ø 16 mm Vane/temperature probe, Ø 25 mm, +0.4 to +40 m/s ±(0.2 m/s ±1% of mv) (+0.4 to +40 m/s) 0635 9640 180 mm -30 to +140 °C can be attached to 0430 3545 handle or 0430 0941 telescopic handle Ø 25 mm Bendable vane probe (can be bent +0.25 to +20 ±(0.1 m/s ±1.5% of mv) (+0.25 to +20 m/s) 0635 9440 m/s by 90°), Ø 60 mm, attachable to handle 0430 3545 or telescopic Ø 60 mm Oper. temp. handle 0430 0941, for meas. on 0 to +60 °C ventilation outlets Bendable vane probe (can be bent +0.1 to +15 m/s ±(0.1 m/s ±1.5% of mv) (+0.1 to +15 m/s) 0635 9340 by 90°), Ø 100 mm, attachable to Oper. temp. handle 0430 3545 or telescopic Ø 100 mm 0 to +60 °C handle 0430 0941, for measurements on ventilation outlets Affordable, robust hot bulb probe, 0 to +10 m/s ±(0.03 m/s ±5% of mv) (0 to +10 m/s) 0635 1549 150 mm -20 to +70 °C Ø 3 mm, for measurements in the lower velocity range, with handle Ø 4 mm Ø 3 mm Robust hot bulb probe, Ø 3 mm, 0 to +10 m/s ±(0.03 m/s ±5% of mv) (0 to +10 m/s) 0635 1049 850 mm -20 to +70 °C with handle and telescopic handle for measurements in the lower velocity range Ø 3 mm Quick-action hot wire probe, Ø 10 0 to +20 m/s ±(0.03 m/s ±4% of mv) (0 to +20 m/s) 0635 1041 760 mm -20 to +70 °C mm, with telescopic handle, for measurements in the lower velocity range with direction recognition Ø 10 mm Robust hot bulb probe, Ø 3 mm, for 0 to +10 m/s ±(0.03 m/s ±5% of mv) (0 to +10 m/s) 0628 0035 150 mm -20 to +70 °C measurements in the lower velocity range, 2m cable (PVC) Ø 3 mm Thermal anemometer probe, Ø 10 0 to +5 m/s ±(0.02 m/s ±5% of mv) (0 to +5 m/s) 0635 1047 760 mm 0 to +50 °C mm, w. telescopic handle, measures air flow in lab fume cupboards to DIN EN 14175 Ø 10 mm Vane probe, Ø 16 mm, with +0.6 to +40 m/s ±(0.2 m/s ±1.5% of mv) (+0.6 to +40 m/s) 0628 0005 700 mm telescopic handle, Tmax +60°C Ø 16 mm High temperature vane probe, Ø 25 +0.6 to +20 m/s ±(0.3 m/s ±1% of fsv) (+0.6 to +20 m/s) 0635 6045 560 mm -40 to +350 °C mm, with handle for continuous measurements up to +350°C Ø 25 mm testovent 415, volume flow funnel, Ø 210 mm/210x210 mm, incl. case 0554 0415 testovent 410, volume flow funnel, Ø 340 mm/330x330 mm, incl. case 0554 0410
  • 6. testo 445 We measure it. Probes Probe type Dimensions Measuring Accuracy Part no. Probe shaft/probe shaft tip range Pressure Precision pressure probe, 100 Pa, 0 to +100 Pa ±(0.3 Pa ±0.5% of mv) (0 to +100 Pa) 0638 1345 measures differential pressure and velocities (in combination with Pitot tube) Pressure probe, 10 hPa, measures 0 to +10 hPa ±0.03 hPa (0 to +10 hPa) 0638 1445 differential pressure and velocities (in combination with Pitot tube) Pressure probe, 100 hPa, measures 0 to +100 hPa ±0.5% of mv (+20 to +100 hPa) 0638 1545 ±0.1 hPa (0 to +20 hPa) differential pressure and velocities (in combination with Pitot tube) Pressure probe, 2000 hPa, 0 to +2000 hPa ±5 hPa (0 to +2000 hPa) 0638 1645 measures absolute pressure Pressure transmitter 0 to 10 bar, to measure pressure in liquid substances 0554 5254 (please also order 1/8" adapter 0554 5200 for pressure range up to 7 bar)
  • 7. testo 445 We measure it. Probes Probe type Dimensions Measuring Part no. Probe shaft/probe shaft tip range Pitot tubes Pitot tube, 500 mm long, Ø 7 mm, Oper. temp. 0635 2045 0 to +600 °C stainless steel, measures flow 500 mm Ø 7 mm speed Pitot tube, 350 mm long, Ø 7 mm, Oper. temp. 0635 2145 0 to +600 °C stainless steel, measures flow 350 mm Ø 7 mm speed Pitot tube, 300 mm long, Ø 4 mm, Oper. temp. 0635 2245 0 to +600 °C stainless steel, measures flow 300 mm Ø 4 mm speed Pitot tube, 1000 mm long, stainless Oper. temp. 0635 2345 0 to +600 °C steel, measures flow speed 1000 mm Ø 7 mm Pitot tube, stainless steel, 1000 mm Probe type 0635 2240 Type K (NiCr- long, measures velocity with Ni) temperature, for pressure probes -40 to +600 °C 0638 1345/..1445/..1545 1000 mm Ø 8 mm Pitot tube, stainless steel, 500 mm Probe type 0635 2140 Type K (NiCr- long, measures velocity with Ni) temperature, for pressure probes -40 to +600 °C 0638 1345/..1445/..1545 500 mm Ø 8 mm Pitot tube, stainless steel, 360 mm Probe type 0635 2040 Type K (NiCr- long, measures velocity with Ni) temperature, for pressure probes -40 to +600 °C 0638 1345/..1445/..1545 360 mm Ø 8 mm
  • 8. testo 445 We measure it. Probes Probe type Dimensions Measuring Accuracy t90 Part no. Probe shaft/probe shaft tip range More probes 3-function probe for simultaneous 0 to +10 m/s ±(0.03 m/s ±5% of mv)(0 to 10 0635 1540 270 mm 0 to +100 %RH m/s) measurement of temperature, -20 to +70 °C ±2 %RH (+2 to +98 %RH) humidity and velocity. With plug-in ±0.4 °C (0 to +50 °C) head, 0430 0143 connection cable Ø 21 mm ±0.5 °C (remaining range) required Comfort level probe for measuring 0 to +5 m/s ±(0.03 m/s ±4% of mv) (0 to +5 0628 0009 890 mm 0 to +50 °C m/s) degree of turbulence, with ±0.3 °C (0 to +50 °C) telescopic handle and stand. Ø 90 mm Fulfills EN 13779 requirements Ambient CO2 probe, Plug-in head, 0 ... +1 Vol. % ±(50 ppm CO2 ±2% of mv) (0 to 0632 1240 CO2 +5000 ppm CO2) connection cable 0430 0143 or 0 ... +10000 ±(100 ppm CO2 ±3% of mv) 0430 0145 required ppm CO2 (+5001 to +10000 ppm CO2) Ambient CO probe, for detecting 0 to +500 ppm ±5% of mv (+100.1 to +500 0632 3331 CO ppm CO) CO in buildings and rooms; 0 to ±5 ppm CO (0 to +100 ppm CO) +500 ppm Humidity probes Standard ambient air probe up to 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 12 s 0636 9740 -20 to +70 °C ±0.4 °C (-10 to +50 °C) +70°C, Plug-in head. connection ±0.5 °C (remaining range) cable 0430 0143 or 0430 0145 required Ø 12 mm Duct humidity/temperature probe, 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 12 s 0636 9715 180 mm -20 to +70 °C ±0.4 °C (-10 to +50 °C) Fixed cable 3 m ±0.5 °C (remaining range) Ø 12 mm Thin humidity probe incl. 4 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 15 s 0636 2130 250 mm -20 to +70 °C ±0.4 °C (-10 to +50 °C) attachable protection caps for ±0.5 °C (-20 to -10.1 °C) ambient air measurements, ±0.5 °C (+50.1 to +70 °C) measurements in exhaust air ducts Ø 4 mm and equilibrium moisture measurements , Plug-in head. connection cable 0430 0143 or 0430 0145 required Highly accurate reference 0 to +100 %RH ±1 %RH (+10 to +90 %RH)* 12 s 0636 9741 -20 to +70 °C ±2 %RH (remaining range) humidity/temp. probe, Plug-in ±0.2 °C (+10 to +40 °C) head. connection cable 0430 0143 Ø 21 mm ±0.4 °C (remaining range) or 0430 0145 required * in the temperature range from +15°C to +30°C Sword probe for measuring 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 12 s 0636 0340 320 mm -20 to +70 °C ±0.4 °C (-10 to +50 °C) humidity and temperature in ±0.5 °C (-20 to -10.1 °C) stacked material, Plug-in head. ±0.5 °C (+50.1 to +70 °C) connection cable 0430 0143 or 18 mm x 5 mm 0430 0145 required High humidity level probe w/ 0 to +100 %RH ±2.5 %RH (0 to +100 %RH) 30 s 0636 2142 300 mm -20 to +85 °C ±0.4 °C (-10 to +50 °C) heated sensor element, no humidity ±0.5 °C (-20 to -10.1 °C) on sensor, Plug-in head. ±0.5 °C (+50.1 to +100 °C) connection cable 0430 0143 or Ø 12 mm 0430 0145 required
  • 9. testo 445 We measure it. Probes Probe type Dimensions Measuring Accuracy t99 Part no. Probe shaft/probe shaft tip range Humidity probes Robust humidity probe e.g. for 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 30 s 0636 2140 300 mm -20 to +120 °C ±0.4 °C (-10 to +50 °C) measuring equilibrium moisture or ±0.5 °C (remaining range) for measurements in exhaust ducts to +120°C, Plug-in head. Ø 12 mm connection cable 0430 0143 or 0430 0145 required Robust high temperature/humidity 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 30 s 0628 0021 300 mm -20 to +180 °C ±0.4 °C (+0.1 to +50 °C) probe up to +180°C , Plug-in head. ±0.5 °C (remaining range) connection cable 0430 0143 or 0430 0145 required Ø 12 mm Flexible humidity probe (does not 0 to +100 %RH ±2 %RH (+2 to +98 %RH) 30 s 0628 0022 1500 mm 100 mm -20 to +180 °C ±0.4 °C (+0.1 to +50 °C) retain shape) for measurements in ±0.5 °C (-20 to 0 °C) inaccessible places , Plug-in head. ±0.5 °C (+50.1 to +180 °C) connection cable 0430 0143 or Ø 12 mm 0430 0145 required Standard pressure dewpoint probe 0 to +100 %RH ±0.9 °C tpd (+0.1 to +50 °C tpd) 0636 9840 300 mm -30 to +50 °C ±1 °C tpd (-4.9 to 0 °C tpd) for measurements in compressed tpd ±2 °C tpd (-9.9 to -5 °C tpd) air systems , Plug-in head. ±3 °C tpd (-19.9 to -10 °C tpd) connection cable 0430 0143 or ±4 °C tpd (-30 to -20 °C tpd) 0430 0145 required Precision pressure dewpoint probe 0 to +100 %RH ±0.8 °C tpd (-4.9 to +50 °C tpd) 0636 9841 300 mm -60 to +50 °C ±1 °C tpd (-9.9 to -5 °C tpd) for measurements in compressed tpd ±2 °C tpd (-19.9 to -10 °C tpd) air systems incl. cert. with test ±3 °C tpd (-29.9 to -20 °C tpd) point -40°C tpd, Plug-in head. ±4 °C tpd (-40 to -30 °C tpd) connection cable 0430 0143 or 0430 0145 required Humidity/temperature probe , Plug- 0... +100 %RH ±2 %RH (+2... +98 %RH) 12 s 0636 9742 -20 to +70 °C ±0.4 °C (+0.1 to +50 °C) in head. connection cable 0430 ±0.5 °C (-20 to 0 °C) 0143 or 0430 0145 required Ø 21 mm ±0.5 °C (+50.1 to +70 °C) Probes aw value aw value set: pressure-tight 0 to +1 aW ±0.01 aW (+0.1 to +0.9 aW) 0628 0024 0 to +100 %RH ±0.02 aW (+0.9 to +1 aW) precision humidity probe with -20 to +70 °C ±1 %RH (+10 to +90 %RH) certificate, measurement chamber ±2 %RH (0 to +10 %RH) and 5 sample bowls (plastic), ±2 %RH (+90 to +100 %RH) ±0.4 °C (-10 to +50 °C) Reproducibility of aw value ±0.003 ±0.5 °C (remaining range)
  • 10. testo 445 We measure it. Probes Probe type Dimensions Measuring Accuracy t99 Part no. Probe shaft/probe shaft tip range Type K (NiCr-Ni) Quick-action surface probe, Plug-in -200 to +300 °C Class 2 1) 3s 0604 0194 150 mm head. connection cable 0430 0143 or 0430 0145 required Ø 10 mm Super quick-action -200 to +600 °C Class 1 1) 1s 0604 0493 150 mm immersion/penetration probe for measurements in liquids , Plug-in head. connection cable 0430 0143 Ø 1.5 mm or 0430 0145 required Super quick-action -200 to +600 °C Class 1 1) 1s 0604 9794 150 mm 20 mm immersion/penetration probe for measurements in gases and liquids with a low-mass tip, Plug-in head. Ø 1.4 mm Ø 0.5 mm connection cable 0430 0143 or 0430 0145 required Robust surface probe , Plug-in -200 to +600 °C Class 1 1) 25 s 0604 9993 150 mm head. connection cable 0430 0143 or 0430 0145 required Ø 4 mm Fast response -200 to +400 °C Class 1 1) 3s 0604 0293 150 mm immersion/penetration probe , Plug-in head. connection cable 0430 0143 or 0430 0145 required Ø 3 mm Super quick-action -200 to Class 1 1) 1s 0604 0593 470 mm +1100 °C immersion/penetration probe for high temperatures , Plug-in head. connection cable 0430 0143 or Ø 1.5 mm 0430 0145 required Spare meas. head for pipe wrap 35 mm -60 to +130 °C Class 2 1) 5s 0602 0092 probe, TC Type K 15 mm Plug-in measuring tip, 750mm long, -200 to +900 °C Class 1 1) 4s 0600 5393 750 mm flexible, for high temperatures, outer casing: stainless steel 1.4541 . Please order handle with Part no. Ø 3 mm 0600 5593 Plug-in measuring tip, 1200 mm -200 to +900 °C Class 1 1) 4s 0600 5493 1200 mm long, flexible, for high temperatures, outer casing: stainless steel 1.4541 . Please Ø 3 mm order handle with Part no. 0600 5593 Plug-in measuring tip, 550mm long, -200 to Class 1 1) 4s 0600 5793 550 mm +1100 °C flexible, for high temperatures, outer casing: Inconel 2.4816 . Please order handle with Part no. Ø 3 mm 0600 5593 Plug-in measuring tip, 1030mm -200 to Class 1 1) 4s 0600 5893 1030 mm +1100 °C long, flexible, for high temperatures, outer casing: Inconel 2.4816 . Please order handle with Ø 3 mm Part no. 0600 5593 1) According to standard EN 60584-2, the accuracy of Classes 1 / 2 refer to -40 to +1000/+1200 °C.
  • 11. testo 445 We measure it. Covering caps Abbildung For humidity probes Part no. Caps for humidity probes Ø 12m and 21mm Metal protection cage, Ø 12 mm for humidity probes, for measurement in 0636 9740, 0636 9715 0554 0755 flow velocities of less than 10 m/s Ø 12 mm Cap with wire mesh filter, Ø 12 mm All humidity probes with Ø 12 0554 0757 mm PTFE sintered filter, Ø 21 mm, for corrosive substances, high humidity All humidity probes with Ø 21 0554 0666 mm range (long-term measurements), high velocities Ø 21 mm Sintered PTFE filter, Ø 12 mm, for corrosive media, High humidity range 0636 9769, 0636 9740, 0636 0554 0756 9715 (long-term measurements), high flow velocities. Ø 12 mm PTFE sintered filter, Ø 12 mm, for corrosive substances, high humidity 0628 0021, 0628 0022, 0636 0554 0758 2140, 0636 2142 range (non-stop measurements), high flow speeds Ø 12 mm Stainless steel sintered cap, Ø 21 mm, can be screwed onto humidity All humidity probes Ø 21 mm 0554 0640 probe, protection in case of high mechanical load and high velocities Ø 21 mm Stainless steel sintered cap, Ø 12 mm, is screwed onto humidity probe, 0636 9740, 0636 9715 0554 0647 for measurements at higher flow velocities or in contaminated air Ø 12 mm PTFE cap, Ø 5 mm, attachable, PTFE material, (5 off) PTFE, Dust 0636 2130 0554 1031 protection, high humidity measurements, high velocities Ø 5 mm
  • 12. testo 445 www.testo.co.uk We measure it. Subject to change without notice. 0981 9714/msp/A/01.2012