Improvements in Data Center
Management
How to Save Energy and Reduce Greenhouse Gases, and Also
Save Money Through Data Center Optimization
November 2010
Contact: jkerner@scottmadden.com
Copyright © 2010 by ScottMadden. All rights reserved.
Purpose
1
◆ Effective data center management is crucial to corporate operations, with several key drivers
— Business continuity
— Data management and security
— Data center operating costs
— Energy usage and GHG management
◆ ScottMadden merges three unique knowledge and skill sets to assist companies in optimizing data center operations and
maintenance costs and performance
— Direct experience in IT systems and data center management
— Multiple people certified in IPMVP Measurement and Verification (M&V) and facility energy audit
— Certification with the Point Carbon/GHG Institute in GHG management
◆ ScottMadden has significant performance management experience with energy companies and Fortune 500 non-energy
corporations and understands how to develop and bring to bear performance management solutions
Copyright © 2010 by ScottMadden. All rights reserved.
Introduction to Data Centers
2
◆ A data center is a centralized repository, either physical or virtual, for the storage, management, and dissemination of data and
information organized around a particular body of knowledge or pertaining to a particular business
◆ A data center generally includes redundant or backup power supplies, redundant data communications connections,
environmental controls (e.g., air conditioning, fire suppression) and security devices
◆ The expanded use of data centers came during 1980’s and 1990’s. Companies needed fast Internet connectivity and nonstop
operation to deploy systems and establish a presence on the Internet. New technologies and practices were designed to handle
the scale and the operational requirements of such large-scale operations
◆ Data centers are typically very expensive to build and maintain, with large company installations costing up to $100 million and
exceeding 100,000 sq ft
◆ Data center design, construction, and operation have developed into an established discipline. Standard documents from
accredited professional groups, specify the requirements for data center design. Well-known operational metrics for data center
availability can be used to evaluate the business impact of a disruption
◆ IT operations are a crucial aspect of most organizational operations. It is necessary to provide a reliable infrastructure for IT
operations, in order to minimize any chance of disruption. Data centers have to offer a secure environment which minimizes the
chances of a security breach
◆ A data center must also maintain high standards for assuring the integrity and functionality of its hosted computer environment.
This is accomplished through redundancy of both fiber optic cables and power, which includes emergency backup power
generation
Effective data center management is crucial to management of corporate business continuity, IT spend, energy
consumption and GHG emissions
Copyright © 2010 by ScottMadden. All rights reserved.
Introduction to Data Centers (Cont’d)
3
The figure below shows the major elements that make up the data center environment.
Source: Pike Research: Green Data Centers, Q3, 2010
Copyright © 2010 by ScottMadden. All rights reserved.
Today’s Data Center Environment
4
◆ The demand for computing power has increased the electrical power required for data centers1: according to an EPA
report to Congress, demand for data processing and storage is driven by several factors:
— The increased use of electronic transactions in financial services, such as online banking and electronic trading
— The growing use of Internet communication and entertainment
— The shift to electronic medical records for healthcare
— The growth in global commerce and services
— The adoption of Smart Meters in Smart Grid applications can increase data points by a significant factor over
traditional electric meters (estimates are from hundreds to thousands of times more data)
— The adoption of satellite navigation and electronic shipment tracking in transportation
— Today’s data centers account for 25 percent of the corporate IT budget for companies
◆ Managing Moore’s Law: the doubling of computer power every18 months defines the fundamental forces that have shaped
the modern data center. There is no sign of an end to this process, but the IT industry is being forced to think about how it
manages the rising demand for data center power2
◆ The virtualized data center: virtualization exploits modern processor power to consolidate servers, saving both energy and
space. Historical server utilization rates were typically under 20 percent. Virtualization pushes server utilization above 80
percent, making better use of hardware investments and supporting energy and cooling costs. Virtualization tools are now
relatively mature and becoming widely adopted. Their impact includes:
— Dramatic reductions in the number of servers required to support a given platform and a corresponding reduction in
the platform’s data center square footage requirements
— Servers used for virtualization are often blade servers – less expensive Intel-based machines running MS Windows or
Linux – with smaller footprints, so more servers can be supported per data center square foot
— Fewer, smaller servers mean less overall space consumed – allowing for data center consolidation:
• Remaining data centers become densely populated (more servers/square foot), increasing total server power
consumption and overall data center cooling requirements (which also consumes more power) – this can limit
how much space a data center can use (data center sq footage previously was the data center’s constraining
factor, it is now power and cooling capacity) – so energy efficiency gains can increase data center capacity
• The resulting denser environment can result in higher data center power consumption
Source: (1) EPA’s “2007 Report to Congress”; (2) Pike Research
Copyright © 2010 by ScottMadden. All rights reserved.
Today’s Data Center Environment (Cont’d)
5
◆ Chip manufacturers are providing more efficient chips
— AMD sensed an opportunity a few years ago and took market share away from Intel by rolling out with more efficient
and cooler chips
— Intel leveraged their R&D machinery to reverse this trend and now evaluates new performance gains against the cost
of power use
◆ Cloud computing continues to grow as a data center consideration – as companies move from private data centers and
private platforms to managed service provider cloud environments, an individuals data center’s power consumption will be
reduced – and offset by the cloud providers potentially more efficient power consumption
◆ Dynamic infrastructure: the difference in refresh rates between IT equipment and the power and cooling infrastructure is a
critical pressure point in the modern data center. While IT servers might be replaced every three years, the infrastructure is
expected to last 10 to 15 years. As IT provisioning becomes more dynamic under the influence of virtualization and cloud
computing, a static view of the infrastructure is no longer feasible. In addition, there is strong financial pressure to avoid
spending hundreds of millions of dollars on new data centers – pressure that is fueling the retrofit of older data centers to
improve energy efficiency and extend their cooling capacity
◆ Integrated management and monitoring systems: a dynamic data center is a much more complex operation than a
traditional static model. As such, it requires more sophisticated management tools and a holistic view of the entire ecosystem. It
also requires much closer working between facilities and IT professionals, which means the data and tools must be able to work
together to optimize the use of power, cooling, and IT resources
◆ Data center inefficiency still remains a problem:
— Despite their immense energy consumption, non-virtualized server utilization rarely exceeds 6 percent and facility
utilization can be as low as 50 percent1
— Data center emissions are expected to quadruple by 2020 - data center electricity consumption is almost 0.2 percent
of world consumption2
— In 2006, the volume server was responsible for the majority (68 percent) of electricity consumed by IT equipment1
— The power and cooling infrastructure that supports the IT equipment accounted for roughly 50 percent of the total
energy consumption of data centers1
Source: (1) McKinsey & Company, “Revolutionizing Data Center Energy Efficiency”; (2) EPA’s “2007 Report to Congress”
Copyright © 2010 by ScottMadden. All rights reserved.
Today’s Data Center Environment (Cont’d)
6
Source: McKinsey & Company, “Revolutionizing Data Center Energy Efficiency”
Copyright © 2010 by ScottMadden. All rights reserved.
Data Center Opportunities
7
◆ Green data center market: The term “green data center” does not lend itself to precise definition. It is broad label for a range of
initiatives that address the environmental impact of data centers, particularly their energy efficiency. The green data center may
also be referred to as a low-carbon data center, an energy-efficient data center, or even a sustainable data center1:
— The green data center market can be defined as the revenue opportunity generated by the operational improvements
and technical innovations that are increasing the energy efficiency of data centers
— The need for a modular, adaptable, and energy-efficient model for the data center is opening opportunities across the
data center supply chain
— Power, cooling, and IT infrastructure suppliers have an enormous opportunity over the next five years to support the
reengineering of the data center infrastructure
— Short-term focus will remain on the technologies developed over the last four or five years that address shortfalls in
the performance of older products
— Going forward, new opportunities are emerging that are centered on greater integration between the data center
infrastructure and the IT assets, which will involve new forms of monitoring, more sophisticated management tools and
greater automation
◆ Real-world efforts to implement energy-efficiency upgrades in data centers have proven highly cost effective. This is illustrated
by a collection of 36 examples from a major telecommunications company. A total one-time investment of over $500,000
yielded $2,000,000 per year in energy savings, for an average payback time of only three months. In ten of the cases, the
improvements were made at no cost (e.g., changes in operations and maintenance procedures)1
◆ According to an EPA data center study, site infrastructure and volume servers continue to be the top contributors to a data
center’s energy usage. Through locating inefficiencies in the systems, data centers can greatly reduce their energy usage. The
Lawrence Berkeley National Laboratory has identified several best practices for optimizing energy efficiency and facility
performance for data centers including: airflow management, air handler systems, humidification, plant optimization, IT
equipment selection, electrical infrastructure, lighting, and commissioning and retrocommissioning2
Source: (1) The Green Grid, “Datacenter Metrics: Describing Datacenter Power Efficiency; (2) Pacific Gas and Electric ,“High Performance Data Centers” and Lawrence Berkeley
National Laboratory
Copyright © 2010 by ScottMadden. All rights reserved.
8
Data Center Upgrades and Improvements
◆ Airflow management – The efficiency and effectiveness of a data center conditioning system is heavily influenced by the path,
temperature, and quantity of cooling air delivered to the IT equipment and waste hot air removed from the equipment
— Eliminate mixing and recirculation of hot equipment exhaust air (e.g., hot aisle/cold aisle configuration, ventilated
racks, flexible barriers, etc.)
— Maintain a larger temperature difference between hot air return and cold air intake
— Maximize return air temperature by supplying air directly to the loads
◆ Air handler systems – The air handler fan is typically the second largest energy use in the mechanical system, and can even
exceed the energy use of the cooling plant in some cases. Optimizing the air handler system for data center use, as opposed to
relying on traditional air handler design rules developed over years of office system design, is essential to achieve an efficient
and cost effective system
— Minimize fan power requirements
— Use an optimized airside economizer
— Use large centralized air handlers
◆ Humidification – Humidification specifications and systems have often been found to be excessive and/or wasteful in data
center facilities. A careful, site specific design approach to these energy-intensive systems is usually needed to avoid energy
waste:
— Eliminate over humidification and/or dehumidification
— Use efficient humidification technology and develop monitoring and testing intervals
◆ Plant optimization – When a chilled water plant is used, all the standard design best practices apply, with a few additions. The
unusual nature of a data center load, which is mostly independent of outside air temperature and solar loads, makes free
cooling very attractive and increases the importance of efficiency over first cost
◆ Uninterruptible power supplies (UPS) — Efficiency losses in a data center's UPS represent about 5 percent to 12 percent of
all the energy consumed in data centers and can total hundreds of thousands of kwh per year. Manufacturer specifications can
differ widely from measured results because of differences in loading conditions and test procedures. There may also be
differences between efficiencies measured under reference conditions and under "in-use" conditions in data centers. Work is
underway to estimate how much energy could be saved by improving UPS efficiency, develop standardized efficiency testing
Source: Pacific Gas and Electric, “High Performance Data Centers,” and Lawrence Berkeley National Laboratory
Copyright © 2010 by ScottMadden. All rights reserved.
9
Data Center Upgrades and Improvements (Cont’d)
protocols, measure the efficiencies of UPS's across a range of load conditions, and propose efficiency metrics for use by the
marketplace in comparing units for purchase
◆ Electrical infrastructure – Protection from power loss is a common characteristic of data center facilities. Such protection
comes at a significant first cost price, and also carries a continuous power usage cost that can be reduced through careful
design and selection
— Design an uninterruptible power supply (UPS) system for efficiency and select most efficient UPS possible
— Use self-generation for large installation
◆ Direct liquid cooling – Water can hold and transfer heat faster than air. It would take 140 cubic feet of air (equivalent to 1280
gallons) to transfer 1kWh as opposed to only 1 gallon of water to transfer 1kWh. As technology advances, data centers are
looking towards direct liquid cooling options for their server racks and ideally each individual component in IT equipment
◆ Lighting – Data centers are typically lightly occupied. While lighting is a small portion of the total power usage of a data center,
it can be often be safely reduced through mature, inexpensive technologies and designs
— Use active sensors to shut off lights when data center is unoccupied
— Design light circuiting and switching to allow for greater manual control
◆ Power supplies - Power supplies convert high voltage AC power into the low voltage data center power needed by the circuitry
found within servers, routers, hubs, switches, data storage units, and other electronic equipment used in data centers and
commercial buildings. Typical server power supplies operate at roughly 65 percent to 75 percent efficiency, meaning that 25 to
35 percent of all the energy consumed by servers is wasted (converted to heat) within their power supplies. The technology
exists to achieve efficiencies of 80 percent to 90 percent in conventional server power supplies
◆ Direct data center power — Even greater efficiencies might be possible by systematically replacing the chain of AC power
generation, AC-data center-AC uninterruptible power supplies, and AC-data center power supplies with a direct data center
power system in data centers. Work is underway to categorize current server power supplies by type, characterize the energy
savings opportunity, develop standardized efficiency testing protocols, measure efficiencies across a range of load conditions,
and propose efficiency metrics that can be employed by power supply buyers, manufacturers, and utilities to accelerate sales of
efficient designs for use in data centers
Source: Pacific Gas and Electric, “High Performance Data Centers,” and Lawrence Berkeley National Laboratory
Copyright © 2010 by ScottMadden. All rights reserved.
10
Data Center Upgrades and Improvements (Cont’d)
◆ Commissioning and retro-commissioning – An efficient data center not only requires a reliable and efficient design, it also
requires proper construction and operation of the space. Commissioning is a methodical and thorough process to ensure the
systems are installed and operating correctly in all aspects, including efficiency
— Engage additional design expertise for review and guidance
— Perform system commissioning and retro-commissioning
— Utilize appropriate measurement and verification (M&V) programs for ongoing performance management
◆ IT equipment selection - The IT equipment is the reason for the facility. Increasingly, there are reasonable opportunities to
increase the efficiency of IT equipment, reducing the need for mechanical infrastructure and ongoing energy use directly at the
load level through the selection of IT equipment
— Efficient microprocessors
• Multiple-core processors
• Dynamic frequency and voltage
• Virtualization opportunities
— Efficient server equipment
• Power management and virtualization
• High efficiency power supplies
• Internal variable speed fans for on-demand cooling
— Cool equipment racks
◆ Fundamental process change — In addition to a host of promising hardware "fixes,” more fundamental innovations have
been proposed, such as shifting all software to the server farms (and away from desktop personal computers). While this would
not save energy in the data center itself, it could reduce the overall demand by simplifying and reducing the power requirements
of hundreds of millions of personal computers. It could also enable more people to telecommute
Source: Pacific Gas and Electric, “High Performance Data Centers,” and Lawrence Berkeley National Laboratory
Copyright © 2010 by ScottMadden. All rights reserved.
Potential GHG Reduction in Data Center Improvements
11
◆ In 2007 the entire information and communication technologies (ICT) sector was estimated to be responsible for roughly 2
percent of global carbon emissions with data centers accounting for 14 percent of the ICT footprint
◆ The U.S. EPA estimates that servers and data centers are responsible for up to 1.5 percent of the total U.S. electricity
consumption, or roughly .5 percent of U.S. GHG emissions for 20071
◆ Although data centers are not a primary source of GHG emissions, due to their high level of electricity consumption, the rapid
growth of data centers’ energy consumption threatens GHG emissions reduction initiatives1
◆ Corporate responsibility initiatives in the U.S. have produced reporting of greenhouse gas emissions, and government agencies
are striving to meet energy goals – it is expected that GHG initiatives will focus on data center efficiency improvements1
Source: (1) EPA, “2007 Report to Congress,” (2) Uptime Institute, “Four Metrics Define Data Center ‘Greenness,’” (3) McKinsey & Company, “Data Centers: How to Cut Carbon
Emissions AND Costs”
◆ According to an analysis by McKinsey &
Company, data center GHG emissions totaled 80
MMTCO2, and are expected to increase by
approximately 425 percent by 20203
◆ Business decisions by companies could result in a
higher data center carbon footprint (e.g., new
growth, new products and services, merger and
acquisition activity, macroeconomic stock, etc.)2
◆ Through locating energy inefficiencies in a data
center’s energy consumption, the carbon footprint
can be minimized
◆ There is a growing trend for LEED certification of
data centers which has shown to be a driver for
increased energy reductions
Copyright © 2010 by ScottMadden. All rights reserved.
Potential GHG Reduction in Data Center Improvements
(Cont’d)
12
◆ Given a business as usual (BAU) scenario greenhouse gas emissions from data centers is projected to more than double from
2007 levels by 20202
— However, in a 2007 Report to Congress, the EPA suggested that energy efficient improvements could decrease
carbon dioxide emissions by 15-47 MMTCO2 given three different levels of energy efficiency scenarios1
◆ Data center GHG reduction opportunities
— Siting is one of the factors that affect the energy consumption and environmental effects of a data center. In areas
where climate favors cooling and renewable electricity is available, the environmental effects could be more moderate
- thus countries with favorable conditions, such as Finland, Sweden, and Switzerland, are trying to attract cloud
computing data centers
— Cloud computing – Many companies have experienced thousands of dollars in annual savings by outsourcing their
computing needs to third parties. Since third parties focus on maximizing performance and efficiency of their
computing operations, they are able to operate at higher levels of utilization than individual companies, thus
decreasing greenhouse gas emissions. An Accenture case study of a Microsoft comparison of onsite carbon
emissions vs. cloud computing carbon emissions showed a reduction of more than 90 percent for small deployments
of about 100 users, 60 to 90 percent for medium-sized deployments of about 1,000 users, and 30 to 60 percent for
large deployments of about 10,000 users when using cloud computing3
— CHP (Combined Heat and Power Systems) and DG (Distributed Generations) – Installation of CHP and DG systems
with absorption cooling can reduce energy costs by producing power more cheaply onsite than if purchased from a
utility. In addition, it can reduce air pollutants through increased efficiency and use of cleaner technologies, which in
turn results in lower levels of fossil fuels combustion and reduced emissions of CO2
1
Improved operation: Operational improvements, no
capital investment
Best practice: Widespread adoption of practices and
technologies used in the most energy efficient facilities
State of the art: Operating at maximum possible energy
efficiency; using the most efficient technologies and best
management practices available today
Source: (1) EPA, “2007 Report to Congress,” (2) Uptime Institute, “Four Metrics Define Data Center ‘Greenness,’” (3) Accenture, “Cloud Computing and Sustainability: The
Environmental Benefits of Moving to the Cloud”
Copyright © 2010 by ScottMadden. All rights reserved.
M&V Requirements in Data Center Improvements
13
◆ Several metrics have been defined in order to measure data center efficiency, locate improvement opportunities, and
benchmark data centers competitively
◆ The Uptime Institute metrics1
— Established the Data Center-EER (Data Center Energy Efficiency Ratio) which is comprised of:
▪ SI-EER (Site Infrastructure Energy Efficiency Ratio) – the ratio of power consumed by the entire facility to the
power consumed by the IT equipment (see PUE)
▪ IT-EER (Information Technology Energy Efficiency Ratio) – the computed performance of IT equipment per
embedded watt of power consumption
— Established four metrics for data center “greenness” – which provide accountabilities for management, IT, and
corporate real estate
• IT strategy
• IT hardware asset utilization
• IT energy and power efficient
hardware deployment
• Site physical infrastructure overhead
— Established three data center sites where
measures can be taken to determine energy
inefficiencies in practices and technologies
• At the meter – determines the demand
charge the data center must pay to the
utility
• At the plug – determines the alternating
current (AC) power consumption at the
hardware plug
• Hardware compute load – determines
the number of watts of direct current
(data center) power that are consumed
within the IT equipment
Source: Uptime Institute, “ Four Metrics Define Data Center ‘Greenness’”
Copyright © 2010 by ScottMadden. All rights reserved.
14
M&V Requirements in Data Center Improvements
(Cont’d)
◆ Lawrence Berkeley National Labs (LBNL)1
— Proposed an overall energy performance benchmark for data centers:
• EUI = kWh / Sq. Ft. / Year / Per Facility
◆ The Green Grid consortium2
— Proposed a formula to benchmark a data center’s energy efficiency as well as to locate opportunities to improve a
data center’s operational efficiency
— PUE (Power Usage Effectiveness) = Total facility power / IT equipment power
— Data Center E (Data Center Efficiency) = IT equipment power / Total facility power
— Explaining the variables
• IT equipment power – the load associated with all of the IT equipment (e.g., compute, storage, and network
equipment) as well as supplemental equipment (KVM switches, monitors, etc.)
• Everything that supports the IT equipment load (e.g., UPS, PDUs, batteries, generators, etc.)
— The Green Grid has a more defined PUE metric system for dedicated data centers, and PUE metrics for data centers
in mixed-use buildings are being defined
◆ ASHRAE3
— Established metrics for determining a data center’s thermal performance
— RCI (Rack Cooling Index) is a measure of the absence of over-temperatures, the lower the percentage the greater
probability that equipment experiences temperatures above the maximum allowable temperature
— RTI (Return Temperature Index) is a measure of the energy performance of the air management system, deviations
from 100 percent are a sign of declining performance
Source: (1) Schneider Electric ,“Tackling Data Center Energy Efficiency Challenges,” (2) The Green Grid, “Green Grid Metrics: Describing Datacenter Power Efficiency,”
(3) ASHRAE, “Airflow and Cooling Performance of Data Centers: Two Performance Metrics”
Copyright © 2010 by ScottMadden. All rights reserved.
ScottMadden Data Center Optimization Methodology
15
Optimizing data center performance requires careful examination of capacity, costs, energy usage, cooling
requirements, and greenhouse gas reduction goals as well as a careful projection of capital outlays and
implementation milestones
◆ Data center capacity
◆ Power and cooling
requirements
◆ Current energy
usage
◆ Current data center
cost structure
◆ Current GHG
emissions
Assess current data
center operations
Project future
data center
operations
Develop
options for
data center
improvements
Develop
strategy for
data center
optimization
Develop data
center
improvement
implementation
plan
◆ Future capacity needs
◆ Future computing
needs
- Security
requirements
- Business continuity
requirements
- Growth of existing
offerings
- Impacts of potential
new service
offerings (internally
identified and/or
market change
driven)
◆ Future IT budgets
◆ Energy efficiency
targets
◆ Server virtualization
options
◆ Computing power
requirements (e.g.,
cloud computing, etc.)
◆ Power consumption
improvement options
◆ Data center cooling
options
◆ GHG requirements
◆ M&V and carbon
management
◆ Explore investments in
power saving
technologies
◆ Plan for data center
scaling requirements
◆ Plan for data center
Power and cooling
usages
◆ Plan for M&V and
carbon management
◆ Plan for attaining
budgeted data center
requirements
◆ Evaluate potential for
LEED certification
◆ Develop gap analysis
◆ Build gap closure plan
- Cost
- Schedule
- Milestones
- M&V implementation
- Energy/carbon
performance
monitoring
◆ Establish data center
metrics and goals
For more information on data centers, please contact us.
Contact Us
Jon D. Kerner
Partner
ScottMadden, Inc.
Ten Piedmont Center
Suite 805
Atlanta, GA 30305
Phone: 678-702-8346
Mobile: 904-718-8935
jkerner@scottmadden.com
16

Mais conteúdo relacionado

Mais procurados

Datacenter best practices design and implementation
Datacenter best practices design and implementationDatacenter best practices design and implementation
Datacenter best practices design and implementationAnton An
 
Data Center Efficiency Workshop 2016
Data Center Efficiency Workshop 2016Data Center Efficiency Workshop 2016
Data Center Efficiency Workshop 2016stexxe
 
Data center design 2
Data center design 2Data center design 2
Data center design 2Aditya Gupta
 
Importance of data centers
Importance of data centersImportance of data centers
Importance of data centersTyrone Systems
 
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...Maria Demitras
 
Datacenter Strategy, Design, and Build
Datacenter Strategy, Design, and BuildDatacenter Strategy, Design, and Build
Datacenter Strategy, Design, and BuildChristopher Kelley
 
Essential elements of data center operations
Essential elements of data center operationsEssential elements of data center operations
Essential elements of data center operationsSchneider Electric
 
Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...
Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...
Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...Upsite Technologies
 
European Data Centre Standards
European Data Centre StandardsEuropean Data Centre Standards
European Data Centre StandardsICT FOOTPRINT .eu
 
Data center maintenance
Data center maintenanceData center maintenance
Data center maintenanceanilinvns
 
Multi tiered hybrid data center design
Multi tiered hybrid data center designMulti tiered hybrid data center design
Multi tiered hybrid data center designMehmet Cetin
 
Data center presentation toi -28022013
Data center presentation   toi -28022013Data center presentation   toi -28022013
Data center presentation toi -28022013Sanjay Belulkar
 
Data center architecture
Data center architecture Data center architecture
Data center architecture RajuPrasad33
 

Mais procurados (20)

Datacenter best practices design and implementation
Datacenter best practices design and implementationDatacenter best practices design and implementation
Datacenter best practices design and implementation
 
Data Center Efficiency Workshop 2016
Data Center Efficiency Workshop 2016Data Center Efficiency Workshop 2016
Data Center Efficiency Workshop 2016
 
Data center design 2
Data center design 2Data center design 2
Data center design 2
 
Importance of data centers
Importance of data centersImportance of data centers
Importance of data centers
 
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
Data Center Floor Design - Your Layout Can Save of Kill Your PUE & Cooling Ef...
 
Modular Data Center Design
Modular Data Center DesignModular Data Center Design
Modular Data Center Design
 
Datacenter Strategy, Design, and Build
Datacenter Strategy, Design, and BuildDatacenter Strategy, Design, and Build
Datacenter Strategy, Design, and Build
 
Data center tier standards
Data center tier standardsData center tier standards
Data center tier standards
 
Data center
Data centerData center
Data center
 
Essential elements of data center operations
Essential elements of data center operationsEssential elements of data center operations
Essential elements of data center operations
 
Data center
Data centerData center
Data center
 
Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...
Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...
Clarifying ASHRAE's Recommended Vs. Allowable Temperature Envelopes and How t...
 
European Data Centre Standards
European Data Centre StandardsEuropean Data Centre Standards
European Data Centre Standards
 
Best Practices for Planning your Datacenter
Best Practices for Planning your DatacenterBest Practices for Planning your Datacenter
Best Practices for Planning your Datacenter
 
Data center maintenance
Data center maintenanceData center maintenance
Data center maintenance
 
Data Center
Data CenterData Center
Data Center
 
Ashrae thermal guidelines svlg 2015 (1)
Ashrae thermal guidelines  svlg 2015 (1)Ashrae thermal guidelines  svlg 2015 (1)
Ashrae thermal guidelines svlg 2015 (1)
 
Multi tiered hybrid data center design
Multi tiered hybrid data center designMulti tiered hybrid data center design
Multi tiered hybrid data center design
 
Data center presentation toi -28022013
Data center presentation   toi -28022013Data center presentation   toi -28022013
Data center presentation toi -28022013
 
Data center architecture
Data center architecture Data center architecture
Data center architecture
 

Semelhante a Improvements in Data Center Management

Commercial Overview DC Session 4 Introduction To Energy In The Data Centre
Commercial Overview   DC Session 4   Introduction To Energy In The Data CentreCommercial Overview   DC Session 4   Introduction To Energy In The Data Centre
Commercial Overview DC Session 4 Introduction To Energy In The Data Centrepaul_mathews
 
Green data center_rahul ppt
Green data center_rahul pptGreen data center_rahul ppt
Green data center_rahul pptRAHUL KAUSHAL
 
Compu Dynamics White Paper - Essential Elements for Data Center Optimization
Compu Dynamics White Paper - Essential Elements for Data Center OptimizationCompu Dynamics White Paper - Essential Elements for Data Center Optimization
Compu Dynamics White Paper - Essential Elements for Data Center OptimizationDan Ephraim
 
The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...
The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...
The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...Heiko Joerg Schick
 
PlanningDataCenterFacilities
PlanningDataCenterFacilitiesPlanningDataCenterFacilities
PlanningDataCenterFacilitiesJoseph Kassl
 
Full chapter in a single perfect format 2
Full chapter in a single perfect format 2Full chapter in a single perfect format 2
Full chapter in a single perfect format 2Snehasis Panigrahi
 
BLOG-POST_DATA CENTER INCENTIVE PROGRAMS
BLOG-POST_DATA CENTER INCENTIVE PROGRAMSBLOG-POST_DATA CENTER INCENTIVE PROGRAMS
BLOG-POST_DATA CENTER INCENTIVE PROGRAMSDaniel Bodenski
 
Grow a Greener Data Center
Grow a Greener Data CenterGrow a Greener Data Center
Grow a Greener Data CenterJamie Shoup
 
Competitive Strategies Benchmarking in Datacenter Infra Industry
Competitive Strategies Benchmarking in Datacenter Infra IndustryCompetitive Strategies Benchmarking in Datacenter Infra Industry
Competitive Strategies Benchmarking in Datacenter Infra IndustryAmit Singh
 
Green Data Centre for banks
Green Data Centre for banksGreen Data Centre for banks
Green Data Centre for banksPritam Raha Roy
 
Data Centre Overview
Data Centre OverviewData Centre Overview
Data Centre OverviewLogicalis
 
Logicalis - Data Centre Overview
Logicalis - Data Centre OverviewLogicalis - Data Centre Overview
Logicalis - Data Centre OverviewLogicalis
 
UK Data Centre Capabilty Presentation Rev.A
UK Data Centre Capabilty Presentation Rev.AUK Data Centre Capabilty Presentation Rev.A
UK Data Centre Capabilty Presentation Rev.AGary Marshall
 

Semelhante a Improvements in Data Center Management (20)

Commercial Overview DC Session 4 Introduction To Energy In The Data Centre
Commercial Overview   DC Session 4   Introduction To Energy In The Data CentreCommercial Overview   DC Session 4   Introduction To Energy In The Data Centre
Commercial Overview DC Session 4 Introduction To Energy In The Data Centre
 
Green data center_rahul ppt
Green data center_rahul pptGreen data center_rahul ppt
Green data center_rahul ppt
 
Express Computer
Express ComputerExpress Computer
Express Computer
 
Compu Dynamics White Paper - Essential Elements for Data Center Optimization
Compu Dynamics White Paper - Essential Elements for Data Center OptimizationCompu Dynamics White Paper - Essential Elements for Data Center Optimization
Compu Dynamics White Paper - Essential Elements for Data Center Optimization
 
The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...
The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...
The 2025 Huawei trend forecast gives you the lowdown on data centre facilitie...
 
PlanningDataCenterFacilities
PlanningDataCenterFacilitiesPlanningDataCenterFacilities
PlanningDataCenterFacilities
 
Full chapter in a single perfect format 2
Full chapter in a single perfect format 2Full chapter in a single perfect format 2
Full chapter in a single perfect format 2
 
The next wave of GreenIT
The next wave of GreenITThe next wave of GreenIT
The next wave of GreenIT
 
Going Modular? Lessons learned from 500 modular data center implementations
Going Modular?  Lessons learned from 500 modular data center implementations Going Modular?  Lessons learned from 500 modular data center implementations
Going Modular? Lessons learned from 500 modular data center implementations
 
BLOG-POST_DATA CENTER INCENTIVE PROGRAMS
BLOG-POST_DATA CENTER INCENTIVE PROGRAMSBLOG-POST_DATA CENTER INCENTIVE PROGRAMS
BLOG-POST_DATA CENTER INCENTIVE PROGRAMS
 
Grow a Greener Data Center
Grow a Greener Data CenterGrow a Greener Data Center
Grow a Greener Data Center
 
009
009009
009
 
Google ppt. mis
Google ppt. misGoogle ppt. mis
Google ppt. mis
 
Competitive Strategies Benchmarking in Datacenter Infra Industry
Competitive Strategies Benchmarking in Datacenter Infra IndustryCompetitive Strategies Benchmarking in Datacenter Infra Industry
Competitive Strategies Benchmarking in Datacenter Infra Industry
 
Green Data Centre for banks
Green Data Centre for banksGreen Data Centre for banks
Green Data Centre for banks
 
Data Centre Overview
Data Centre OverviewData Centre Overview
Data Centre Overview
 
Logicalis - Data Centre Overview
Logicalis - Data Centre OverviewLogicalis - Data Centre Overview
Logicalis - Data Centre Overview
 
Executive DCIM
Executive DCIMExecutive DCIM
Executive DCIM
 
UK Data Centre Capabilty Presentation Rev.A
UK Data Centre Capabilty Presentation Rev.AUK Data Centre Capabilty Presentation Rev.A
UK Data Centre Capabilty Presentation Rev.A
 
Green IT
Green IT Green IT
Green IT
 

Mais de ScottMadden, Inc.

Creating IT Value-A Better Way to Make IT Investment Decisions
Creating IT Value-A Better Way to Make IT Investment DecisionsCreating IT Value-A Better Way to Make IT Investment Decisions
Creating IT Value-A Better Way to Make IT Investment DecisionsScottMadden, Inc.
 
Benchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCsBenchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCsScottMadden, Inc.
 
Benchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCsBenchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCsScottMadden, Inc.
 
ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis ScottMadden, Inc.
 
Overcoming the Challenges of Large Capital Programs/Projects
Overcoming the Challenges of Large Capital Programs/ProjectsOvercoming the Challenges of Large Capital Programs/Projects
Overcoming the Challenges of Large Capital Programs/ProjectsScottMadden, Inc.
 
ScottMadden HR Shared Services Benchmarking Study Highlights 2019
ScottMadden HR Shared Services Benchmarking Study Highlights 2019ScottMadden HR Shared Services Benchmarking Study Highlights 2019
ScottMadden HR Shared Services Benchmarking Study Highlights 2019ScottMadden, Inc.
 
ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis ScottMadden, Inc.
 
ScottMadden Finance Shared Services Benchmark Highlights 2020
ScottMadden Finance Shared Services Benchmark Highlights 2020ScottMadden Finance Shared Services Benchmark Highlights 2020
ScottMadden Finance Shared Services Benchmark Highlights 2020ScottMadden, Inc.
 
The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...
The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...
The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...ScottMadden, Inc.
 
ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...
ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...
ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...ScottMadden, Inc.
 
Energy Industry Update Webcast: Don't Stop Believin'
Energy Industry Update Webcast: Don't Stop Believin'Energy Industry Update Webcast: Don't Stop Believin'
Energy Industry Update Webcast: Don't Stop Believin'ScottMadden, Inc.
 
Technology for HR Shared Services
Technology for HR Shared ServicesTechnology for HR Shared Services
Technology for HR Shared ServicesScottMadden, Inc.
 
Building a Business Case for Shared Services
Building a Business Case for Shared ServicesBuilding a Business Case for Shared Services
Building a Business Case for Shared ServicesScottMadden, Inc.
 
Fundamentals of Designing, Building, & Implementing a Service Delivery Center
Fundamentals of Designing, Building, & Implementing a Service Delivery CenterFundamentals of Designing, Building, & Implementing a Service Delivery Center
Fundamentals of Designing, Building, & Implementing a Service Delivery CenterScottMadden, Inc.
 
Next Generation Shared Services Centers
Next Generation Shared Services CentersNext Generation Shared Services Centers
Next Generation Shared Services CentersScottMadden, Inc.
 
California’s Combined Cycle Costs in the Age of the Duck Curve
California’s Combined Cycle Costs in the Age of the Duck CurveCalifornia’s Combined Cycle Costs in the Age of the Duck Curve
California’s Combined Cycle Costs in the Age of the Duck CurveScottMadden, Inc.
 
Capital Program Assessment Overview
Capital Program Assessment OverviewCapital Program Assessment Overview
Capital Program Assessment OverviewScottMadden, Inc.
 
Value of Strategic Direction
Value of Strategic DirectionValue of Strategic Direction
Value of Strategic DirectionScottMadden, Inc.
 
Generation Trends: What are the Impacts on Transmission?
Generation Trends: What are the Impacts on Transmission? Generation Trends: What are the Impacts on Transmission?
Generation Trends: What are the Impacts on Transmission? ScottMadden, Inc.
 

Mais de ScottMadden, Inc. (20)

Creating IT Value-A Better Way to Make IT Investment Decisions
Creating IT Value-A Better Way to Make IT Investment DecisionsCreating IT Value-A Better Way to Make IT Investment Decisions
Creating IT Value-A Better Way to Make IT Investment Decisions
 
Benchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCsBenchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCs
 
Benchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCsBenchmarking for Natural Gas LDCs
Benchmarking for Natural Gas LDCs
 
ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis
 
Overcoming the Challenges of Large Capital Programs/Projects
Overcoming the Challenges of Large Capital Programs/ProjectsOvercoming the Challenges of Large Capital Programs/Projects
Overcoming the Challenges of Large Capital Programs/Projects
 
ScottMadden HR Shared Services Benchmarking Study Highlights 2019
ScottMadden HR Shared Services Benchmarking Study Highlights 2019ScottMadden HR Shared Services Benchmarking Study Highlights 2019
ScottMadden HR Shared Services Benchmarking Study Highlights 2019
 
ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis ScottMadden Fossil Benchmarking Analysis
ScottMadden Fossil Benchmarking Analysis
 
ScottMadden Finance Shared Services Benchmark Highlights 2020
ScottMadden Finance Shared Services Benchmark Highlights 2020ScottMadden Finance Shared Services Benchmark Highlights 2020
ScottMadden Finance Shared Services Benchmark Highlights 2020
 
The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...
The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...
The ScottMadden Energy Industry Update Webcast: Everything Counts ... In Larg...
 
ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...
ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...
ScottMadden's Energy Industry Update for the 2019 Utility Supply Chain Confer...
 
Energy Industry Update Webcast: Don't Stop Believin'
Energy Industry Update Webcast: Don't Stop Believin'Energy Industry Update Webcast: Don't Stop Believin'
Energy Industry Update Webcast: Don't Stop Believin'
 
Combined Cycles
Combined CyclesCombined Cycles
Combined Cycles
 
Technology for HR Shared Services
Technology for HR Shared ServicesTechnology for HR Shared Services
Technology for HR Shared Services
 
Building a Business Case for Shared Services
Building a Business Case for Shared ServicesBuilding a Business Case for Shared Services
Building a Business Case for Shared Services
 
Fundamentals of Designing, Building, & Implementing a Service Delivery Center
Fundamentals of Designing, Building, & Implementing a Service Delivery CenterFundamentals of Designing, Building, & Implementing a Service Delivery Center
Fundamentals of Designing, Building, & Implementing a Service Delivery Center
 
Next Generation Shared Services Centers
Next Generation Shared Services CentersNext Generation Shared Services Centers
Next Generation Shared Services Centers
 
California’s Combined Cycle Costs in the Age of the Duck Curve
California’s Combined Cycle Costs in the Age of the Duck CurveCalifornia’s Combined Cycle Costs in the Age of the Duck Curve
California’s Combined Cycle Costs in the Age of the Duck Curve
 
Capital Program Assessment Overview
Capital Program Assessment OverviewCapital Program Assessment Overview
Capital Program Assessment Overview
 
Value of Strategic Direction
Value of Strategic DirectionValue of Strategic Direction
Value of Strategic Direction
 
Generation Trends: What are the Impacts on Transmission?
Generation Trends: What are the Impacts on Transmission? Generation Trends: What are the Impacts on Transmission?
Generation Trends: What are the Impacts on Transmission?
 

Último

This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.christianmathematics
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxDenish Jangid
 
On National Teacher Day, meet the 2024-25 Kenan Fellows
On National Teacher Day, meet the 2024-25 Kenan FellowsOn National Teacher Day, meet the 2024-25 Kenan Fellows
On National Teacher Day, meet the 2024-25 Kenan FellowsMebane Rash
 
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptxCOMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptxannathomasp01
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...pradhanghanshyam7136
 
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Pooja Bhuva
 
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptxOn_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptxPooja Bhuva
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxJisc
 
Graduate Outcomes Presentation Slides - English
Graduate Outcomes Presentation Slides - EnglishGraduate Outcomes Presentation Slides - English
Graduate Outcomes Presentation Slides - Englishneillewis46
 
Sociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning ExhibitSociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning Exhibitjbellavia9
 
How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17Celine George
 
Python Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxPython Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxRamakrishna Reddy Bijjam
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfagholdier
 
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptxHMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptxmarlenawright1
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...ZurliaSoop
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...Poonam Aher Patil
 
REMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptxREMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptxDr. Ravikiran H M Gowda
 
How to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSHow to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSCeline George
 
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptxExploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptxPooja Bhuva
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxheathfieldcps1
 

Último (20)

This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
 
On National Teacher Day, meet the 2024-25 Kenan Fellows
On National Teacher Day, meet the 2024-25 Kenan FellowsOn National Teacher Day, meet the 2024-25 Kenan Fellows
On National Teacher Day, meet the 2024-25 Kenan Fellows
 
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptxCOMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
 
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
 
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptxOn_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptx
 
Graduate Outcomes Presentation Slides - English
Graduate Outcomes Presentation Slides - EnglishGraduate Outcomes Presentation Slides - English
Graduate Outcomes Presentation Slides - English
 
Sociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning ExhibitSociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning Exhibit
 
How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17
 
Python Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxPython Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docx
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdf
 
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptxHMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...
 
REMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptxREMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptx
 
How to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSHow to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POS
 
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptxExploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
Exploring_the_Narrative_Style_of_Amitav_Ghoshs_Gun_Island.pptx
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptx
 

Improvements in Data Center Management

  • 1. Copyright © 2010 by ScottMadden. All rights reserved. Improvements in Data Center Management How to Save Energy and Reduce Greenhouse Gases, and Also Save Money Through Data Center Optimization November 2010 Contact: jkerner@scottmadden.com
  • 2. Copyright © 2010 by ScottMadden. All rights reserved. Purpose 1 ◆ Effective data center management is crucial to corporate operations, with several key drivers — Business continuity — Data management and security — Data center operating costs — Energy usage and GHG management ◆ ScottMadden merges three unique knowledge and skill sets to assist companies in optimizing data center operations and maintenance costs and performance — Direct experience in IT systems and data center management — Multiple people certified in IPMVP Measurement and Verification (M&V) and facility energy audit — Certification with the Point Carbon/GHG Institute in GHG management ◆ ScottMadden has significant performance management experience with energy companies and Fortune 500 non-energy corporations and understands how to develop and bring to bear performance management solutions
  • 3. Copyright © 2010 by ScottMadden. All rights reserved. Introduction to Data Centers 2 ◆ A data center is a centralized repository, either physical or virtual, for the storage, management, and dissemination of data and information organized around a particular body of knowledge or pertaining to a particular business ◆ A data center generally includes redundant or backup power supplies, redundant data communications connections, environmental controls (e.g., air conditioning, fire suppression) and security devices ◆ The expanded use of data centers came during 1980’s and 1990’s. Companies needed fast Internet connectivity and nonstop operation to deploy systems and establish a presence on the Internet. New technologies and practices were designed to handle the scale and the operational requirements of such large-scale operations ◆ Data centers are typically very expensive to build and maintain, with large company installations costing up to $100 million and exceeding 100,000 sq ft ◆ Data center design, construction, and operation have developed into an established discipline. Standard documents from accredited professional groups, specify the requirements for data center design. Well-known operational metrics for data center availability can be used to evaluate the business impact of a disruption ◆ IT operations are a crucial aspect of most organizational operations. It is necessary to provide a reliable infrastructure for IT operations, in order to minimize any chance of disruption. Data centers have to offer a secure environment which minimizes the chances of a security breach ◆ A data center must also maintain high standards for assuring the integrity and functionality of its hosted computer environment. This is accomplished through redundancy of both fiber optic cables and power, which includes emergency backup power generation Effective data center management is crucial to management of corporate business continuity, IT spend, energy consumption and GHG emissions
  • 4. Copyright © 2010 by ScottMadden. All rights reserved. Introduction to Data Centers (Cont’d) 3 The figure below shows the major elements that make up the data center environment. Source: Pike Research: Green Data Centers, Q3, 2010
  • 5. Copyright © 2010 by ScottMadden. All rights reserved. Today’s Data Center Environment 4 ◆ The demand for computing power has increased the electrical power required for data centers1: according to an EPA report to Congress, demand for data processing and storage is driven by several factors: — The increased use of electronic transactions in financial services, such as online banking and electronic trading — The growing use of Internet communication and entertainment — The shift to electronic medical records for healthcare — The growth in global commerce and services — The adoption of Smart Meters in Smart Grid applications can increase data points by a significant factor over traditional electric meters (estimates are from hundreds to thousands of times more data) — The adoption of satellite navigation and electronic shipment tracking in transportation — Today’s data centers account for 25 percent of the corporate IT budget for companies ◆ Managing Moore’s Law: the doubling of computer power every18 months defines the fundamental forces that have shaped the modern data center. There is no sign of an end to this process, but the IT industry is being forced to think about how it manages the rising demand for data center power2 ◆ The virtualized data center: virtualization exploits modern processor power to consolidate servers, saving both energy and space. Historical server utilization rates were typically under 20 percent. Virtualization pushes server utilization above 80 percent, making better use of hardware investments and supporting energy and cooling costs. Virtualization tools are now relatively mature and becoming widely adopted. Their impact includes: — Dramatic reductions in the number of servers required to support a given platform and a corresponding reduction in the platform’s data center square footage requirements — Servers used for virtualization are often blade servers – less expensive Intel-based machines running MS Windows or Linux – with smaller footprints, so more servers can be supported per data center square foot — Fewer, smaller servers mean less overall space consumed – allowing for data center consolidation: • Remaining data centers become densely populated (more servers/square foot), increasing total server power consumption and overall data center cooling requirements (which also consumes more power) – this can limit how much space a data center can use (data center sq footage previously was the data center’s constraining factor, it is now power and cooling capacity) – so energy efficiency gains can increase data center capacity • The resulting denser environment can result in higher data center power consumption Source: (1) EPA’s “2007 Report to Congress”; (2) Pike Research
  • 6. Copyright © 2010 by ScottMadden. All rights reserved. Today’s Data Center Environment (Cont’d) 5 ◆ Chip manufacturers are providing more efficient chips — AMD sensed an opportunity a few years ago and took market share away from Intel by rolling out with more efficient and cooler chips — Intel leveraged their R&D machinery to reverse this trend and now evaluates new performance gains against the cost of power use ◆ Cloud computing continues to grow as a data center consideration – as companies move from private data centers and private platforms to managed service provider cloud environments, an individuals data center’s power consumption will be reduced – and offset by the cloud providers potentially more efficient power consumption ◆ Dynamic infrastructure: the difference in refresh rates between IT equipment and the power and cooling infrastructure is a critical pressure point in the modern data center. While IT servers might be replaced every three years, the infrastructure is expected to last 10 to 15 years. As IT provisioning becomes more dynamic under the influence of virtualization and cloud computing, a static view of the infrastructure is no longer feasible. In addition, there is strong financial pressure to avoid spending hundreds of millions of dollars on new data centers – pressure that is fueling the retrofit of older data centers to improve energy efficiency and extend their cooling capacity ◆ Integrated management and monitoring systems: a dynamic data center is a much more complex operation than a traditional static model. As such, it requires more sophisticated management tools and a holistic view of the entire ecosystem. It also requires much closer working between facilities and IT professionals, which means the data and tools must be able to work together to optimize the use of power, cooling, and IT resources ◆ Data center inefficiency still remains a problem: — Despite their immense energy consumption, non-virtualized server utilization rarely exceeds 6 percent and facility utilization can be as low as 50 percent1 — Data center emissions are expected to quadruple by 2020 - data center electricity consumption is almost 0.2 percent of world consumption2 — In 2006, the volume server was responsible for the majority (68 percent) of electricity consumed by IT equipment1 — The power and cooling infrastructure that supports the IT equipment accounted for roughly 50 percent of the total energy consumption of data centers1 Source: (1) McKinsey & Company, “Revolutionizing Data Center Energy Efficiency”; (2) EPA’s “2007 Report to Congress”
  • 7. Copyright © 2010 by ScottMadden. All rights reserved. Today’s Data Center Environment (Cont’d) 6 Source: McKinsey & Company, “Revolutionizing Data Center Energy Efficiency”
  • 8. Copyright © 2010 by ScottMadden. All rights reserved. Data Center Opportunities 7 ◆ Green data center market: The term “green data center” does not lend itself to precise definition. It is broad label for a range of initiatives that address the environmental impact of data centers, particularly their energy efficiency. The green data center may also be referred to as a low-carbon data center, an energy-efficient data center, or even a sustainable data center1: — The green data center market can be defined as the revenue opportunity generated by the operational improvements and technical innovations that are increasing the energy efficiency of data centers — The need for a modular, adaptable, and energy-efficient model for the data center is opening opportunities across the data center supply chain — Power, cooling, and IT infrastructure suppliers have an enormous opportunity over the next five years to support the reengineering of the data center infrastructure — Short-term focus will remain on the technologies developed over the last four or five years that address shortfalls in the performance of older products — Going forward, new opportunities are emerging that are centered on greater integration between the data center infrastructure and the IT assets, which will involve new forms of monitoring, more sophisticated management tools and greater automation ◆ Real-world efforts to implement energy-efficiency upgrades in data centers have proven highly cost effective. This is illustrated by a collection of 36 examples from a major telecommunications company. A total one-time investment of over $500,000 yielded $2,000,000 per year in energy savings, for an average payback time of only three months. In ten of the cases, the improvements were made at no cost (e.g., changes in operations and maintenance procedures)1 ◆ According to an EPA data center study, site infrastructure and volume servers continue to be the top contributors to a data center’s energy usage. Through locating inefficiencies in the systems, data centers can greatly reduce their energy usage. The Lawrence Berkeley National Laboratory has identified several best practices for optimizing energy efficiency and facility performance for data centers including: airflow management, air handler systems, humidification, plant optimization, IT equipment selection, electrical infrastructure, lighting, and commissioning and retrocommissioning2 Source: (1) The Green Grid, “Datacenter Metrics: Describing Datacenter Power Efficiency; (2) Pacific Gas and Electric ,“High Performance Data Centers” and Lawrence Berkeley National Laboratory
  • 9. Copyright © 2010 by ScottMadden. All rights reserved. 8 Data Center Upgrades and Improvements ◆ Airflow management – The efficiency and effectiveness of a data center conditioning system is heavily influenced by the path, temperature, and quantity of cooling air delivered to the IT equipment and waste hot air removed from the equipment — Eliminate mixing and recirculation of hot equipment exhaust air (e.g., hot aisle/cold aisle configuration, ventilated racks, flexible barriers, etc.) — Maintain a larger temperature difference between hot air return and cold air intake — Maximize return air temperature by supplying air directly to the loads ◆ Air handler systems – The air handler fan is typically the second largest energy use in the mechanical system, and can even exceed the energy use of the cooling plant in some cases. Optimizing the air handler system for data center use, as opposed to relying on traditional air handler design rules developed over years of office system design, is essential to achieve an efficient and cost effective system — Minimize fan power requirements — Use an optimized airside economizer — Use large centralized air handlers ◆ Humidification – Humidification specifications and systems have often been found to be excessive and/or wasteful in data center facilities. A careful, site specific design approach to these energy-intensive systems is usually needed to avoid energy waste: — Eliminate over humidification and/or dehumidification — Use efficient humidification technology and develop monitoring and testing intervals ◆ Plant optimization – When a chilled water plant is used, all the standard design best practices apply, with a few additions. The unusual nature of a data center load, which is mostly independent of outside air temperature and solar loads, makes free cooling very attractive and increases the importance of efficiency over first cost ◆ Uninterruptible power supplies (UPS) — Efficiency losses in a data center's UPS represent about 5 percent to 12 percent of all the energy consumed in data centers and can total hundreds of thousands of kwh per year. Manufacturer specifications can differ widely from measured results because of differences in loading conditions and test procedures. There may also be differences between efficiencies measured under reference conditions and under "in-use" conditions in data centers. Work is underway to estimate how much energy could be saved by improving UPS efficiency, develop standardized efficiency testing Source: Pacific Gas and Electric, “High Performance Data Centers,” and Lawrence Berkeley National Laboratory
  • 10. Copyright © 2010 by ScottMadden. All rights reserved. 9 Data Center Upgrades and Improvements (Cont’d) protocols, measure the efficiencies of UPS's across a range of load conditions, and propose efficiency metrics for use by the marketplace in comparing units for purchase ◆ Electrical infrastructure – Protection from power loss is a common characteristic of data center facilities. Such protection comes at a significant first cost price, and also carries a continuous power usage cost that can be reduced through careful design and selection — Design an uninterruptible power supply (UPS) system for efficiency and select most efficient UPS possible — Use self-generation for large installation ◆ Direct liquid cooling – Water can hold and transfer heat faster than air. It would take 140 cubic feet of air (equivalent to 1280 gallons) to transfer 1kWh as opposed to only 1 gallon of water to transfer 1kWh. As technology advances, data centers are looking towards direct liquid cooling options for their server racks and ideally each individual component in IT equipment ◆ Lighting – Data centers are typically lightly occupied. While lighting is a small portion of the total power usage of a data center, it can be often be safely reduced through mature, inexpensive technologies and designs — Use active sensors to shut off lights when data center is unoccupied — Design light circuiting and switching to allow for greater manual control ◆ Power supplies - Power supplies convert high voltage AC power into the low voltage data center power needed by the circuitry found within servers, routers, hubs, switches, data storage units, and other electronic equipment used in data centers and commercial buildings. Typical server power supplies operate at roughly 65 percent to 75 percent efficiency, meaning that 25 to 35 percent of all the energy consumed by servers is wasted (converted to heat) within their power supplies. The technology exists to achieve efficiencies of 80 percent to 90 percent in conventional server power supplies ◆ Direct data center power — Even greater efficiencies might be possible by systematically replacing the chain of AC power generation, AC-data center-AC uninterruptible power supplies, and AC-data center power supplies with a direct data center power system in data centers. Work is underway to categorize current server power supplies by type, characterize the energy savings opportunity, develop standardized efficiency testing protocols, measure efficiencies across a range of load conditions, and propose efficiency metrics that can be employed by power supply buyers, manufacturers, and utilities to accelerate sales of efficient designs for use in data centers Source: Pacific Gas and Electric, “High Performance Data Centers,” and Lawrence Berkeley National Laboratory
  • 11. Copyright © 2010 by ScottMadden. All rights reserved. 10 Data Center Upgrades and Improvements (Cont’d) ◆ Commissioning and retro-commissioning – An efficient data center not only requires a reliable and efficient design, it also requires proper construction and operation of the space. Commissioning is a methodical and thorough process to ensure the systems are installed and operating correctly in all aspects, including efficiency — Engage additional design expertise for review and guidance — Perform system commissioning and retro-commissioning — Utilize appropriate measurement and verification (M&V) programs for ongoing performance management ◆ IT equipment selection - The IT equipment is the reason for the facility. Increasingly, there are reasonable opportunities to increase the efficiency of IT equipment, reducing the need for mechanical infrastructure and ongoing energy use directly at the load level through the selection of IT equipment — Efficient microprocessors • Multiple-core processors • Dynamic frequency and voltage • Virtualization opportunities — Efficient server equipment • Power management and virtualization • High efficiency power supplies • Internal variable speed fans for on-demand cooling — Cool equipment racks ◆ Fundamental process change — In addition to a host of promising hardware "fixes,” more fundamental innovations have been proposed, such as shifting all software to the server farms (and away from desktop personal computers). While this would not save energy in the data center itself, it could reduce the overall demand by simplifying and reducing the power requirements of hundreds of millions of personal computers. It could also enable more people to telecommute Source: Pacific Gas and Electric, “High Performance Data Centers,” and Lawrence Berkeley National Laboratory
  • 12. Copyright © 2010 by ScottMadden. All rights reserved. Potential GHG Reduction in Data Center Improvements 11 ◆ In 2007 the entire information and communication technologies (ICT) sector was estimated to be responsible for roughly 2 percent of global carbon emissions with data centers accounting for 14 percent of the ICT footprint ◆ The U.S. EPA estimates that servers and data centers are responsible for up to 1.5 percent of the total U.S. electricity consumption, or roughly .5 percent of U.S. GHG emissions for 20071 ◆ Although data centers are not a primary source of GHG emissions, due to their high level of electricity consumption, the rapid growth of data centers’ energy consumption threatens GHG emissions reduction initiatives1 ◆ Corporate responsibility initiatives in the U.S. have produced reporting of greenhouse gas emissions, and government agencies are striving to meet energy goals – it is expected that GHG initiatives will focus on data center efficiency improvements1 Source: (1) EPA, “2007 Report to Congress,” (2) Uptime Institute, “Four Metrics Define Data Center ‘Greenness,’” (3) McKinsey & Company, “Data Centers: How to Cut Carbon Emissions AND Costs” ◆ According to an analysis by McKinsey & Company, data center GHG emissions totaled 80 MMTCO2, and are expected to increase by approximately 425 percent by 20203 ◆ Business decisions by companies could result in a higher data center carbon footprint (e.g., new growth, new products and services, merger and acquisition activity, macroeconomic stock, etc.)2 ◆ Through locating energy inefficiencies in a data center’s energy consumption, the carbon footprint can be minimized ◆ There is a growing trend for LEED certification of data centers which has shown to be a driver for increased energy reductions
  • 13. Copyright © 2010 by ScottMadden. All rights reserved. Potential GHG Reduction in Data Center Improvements (Cont’d) 12 ◆ Given a business as usual (BAU) scenario greenhouse gas emissions from data centers is projected to more than double from 2007 levels by 20202 — However, in a 2007 Report to Congress, the EPA suggested that energy efficient improvements could decrease carbon dioxide emissions by 15-47 MMTCO2 given three different levels of energy efficiency scenarios1 ◆ Data center GHG reduction opportunities — Siting is one of the factors that affect the energy consumption and environmental effects of a data center. In areas where climate favors cooling and renewable electricity is available, the environmental effects could be more moderate - thus countries with favorable conditions, such as Finland, Sweden, and Switzerland, are trying to attract cloud computing data centers — Cloud computing – Many companies have experienced thousands of dollars in annual savings by outsourcing their computing needs to third parties. Since third parties focus on maximizing performance and efficiency of their computing operations, they are able to operate at higher levels of utilization than individual companies, thus decreasing greenhouse gas emissions. An Accenture case study of a Microsoft comparison of onsite carbon emissions vs. cloud computing carbon emissions showed a reduction of more than 90 percent for small deployments of about 100 users, 60 to 90 percent for medium-sized deployments of about 1,000 users, and 30 to 60 percent for large deployments of about 10,000 users when using cloud computing3 — CHP (Combined Heat and Power Systems) and DG (Distributed Generations) – Installation of CHP and DG systems with absorption cooling can reduce energy costs by producing power more cheaply onsite than if purchased from a utility. In addition, it can reduce air pollutants through increased efficiency and use of cleaner technologies, which in turn results in lower levels of fossil fuels combustion and reduced emissions of CO2 1 Improved operation: Operational improvements, no capital investment Best practice: Widespread adoption of practices and technologies used in the most energy efficient facilities State of the art: Operating at maximum possible energy efficiency; using the most efficient technologies and best management practices available today Source: (1) EPA, “2007 Report to Congress,” (2) Uptime Institute, “Four Metrics Define Data Center ‘Greenness,’” (3) Accenture, “Cloud Computing and Sustainability: The Environmental Benefits of Moving to the Cloud”
  • 14. Copyright © 2010 by ScottMadden. All rights reserved. M&V Requirements in Data Center Improvements 13 ◆ Several metrics have been defined in order to measure data center efficiency, locate improvement opportunities, and benchmark data centers competitively ◆ The Uptime Institute metrics1 — Established the Data Center-EER (Data Center Energy Efficiency Ratio) which is comprised of: ▪ SI-EER (Site Infrastructure Energy Efficiency Ratio) – the ratio of power consumed by the entire facility to the power consumed by the IT equipment (see PUE) ▪ IT-EER (Information Technology Energy Efficiency Ratio) – the computed performance of IT equipment per embedded watt of power consumption — Established four metrics for data center “greenness” – which provide accountabilities for management, IT, and corporate real estate • IT strategy • IT hardware asset utilization • IT energy and power efficient hardware deployment • Site physical infrastructure overhead — Established three data center sites where measures can be taken to determine energy inefficiencies in practices and technologies • At the meter – determines the demand charge the data center must pay to the utility • At the plug – determines the alternating current (AC) power consumption at the hardware plug • Hardware compute load – determines the number of watts of direct current (data center) power that are consumed within the IT equipment Source: Uptime Institute, “ Four Metrics Define Data Center ‘Greenness’”
  • 15. Copyright © 2010 by ScottMadden. All rights reserved. 14 M&V Requirements in Data Center Improvements (Cont’d) ◆ Lawrence Berkeley National Labs (LBNL)1 — Proposed an overall energy performance benchmark for data centers: • EUI = kWh / Sq. Ft. / Year / Per Facility ◆ The Green Grid consortium2 — Proposed a formula to benchmark a data center’s energy efficiency as well as to locate opportunities to improve a data center’s operational efficiency — PUE (Power Usage Effectiveness) = Total facility power / IT equipment power — Data Center E (Data Center Efficiency) = IT equipment power / Total facility power — Explaining the variables • IT equipment power – the load associated with all of the IT equipment (e.g., compute, storage, and network equipment) as well as supplemental equipment (KVM switches, monitors, etc.) • Everything that supports the IT equipment load (e.g., UPS, PDUs, batteries, generators, etc.) — The Green Grid has a more defined PUE metric system for dedicated data centers, and PUE metrics for data centers in mixed-use buildings are being defined ◆ ASHRAE3 — Established metrics for determining a data center’s thermal performance — RCI (Rack Cooling Index) is a measure of the absence of over-temperatures, the lower the percentage the greater probability that equipment experiences temperatures above the maximum allowable temperature — RTI (Return Temperature Index) is a measure of the energy performance of the air management system, deviations from 100 percent are a sign of declining performance Source: (1) Schneider Electric ,“Tackling Data Center Energy Efficiency Challenges,” (2) The Green Grid, “Green Grid Metrics: Describing Datacenter Power Efficiency,” (3) ASHRAE, “Airflow and Cooling Performance of Data Centers: Two Performance Metrics”
  • 16. Copyright © 2010 by ScottMadden. All rights reserved. ScottMadden Data Center Optimization Methodology 15 Optimizing data center performance requires careful examination of capacity, costs, energy usage, cooling requirements, and greenhouse gas reduction goals as well as a careful projection of capital outlays and implementation milestones ◆ Data center capacity ◆ Power and cooling requirements ◆ Current energy usage ◆ Current data center cost structure ◆ Current GHG emissions Assess current data center operations Project future data center operations Develop options for data center improvements Develop strategy for data center optimization Develop data center improvement implementation plan ◆ Future capacity needs ◆ Future computing needs - Security requirements - Business continuity requirements - Growth of existing offerings - Impacts of potential new service offerings (internally identified and/or market change driven) ◆ Future IT budgets ◆ Energy efficiency targets ◆ Server virtualization options ◆ Computing power requirements (e.g., cloud computing, etc.) ◆ Power consumption improvement options ◆ Data center cooling options ◆ GHG requirements ◆ M&V and carbon management ◆ Explore investments in power saving technologies ◆ Plan for data center scaling requirements ◆ Plan for data center Power and cooling usages ◆ Plan for M&V and carbon management ◆ Plan for attaining budgeted data center requirements ◆ Evaluate potential for LEED certification ◆ Develop gap analysis ◆ Build gap closure plan - Cost - Schedule - Milestones - M&V implementation - Energy/carbon performance monitoring ◆ Establish data center metrics and goals
  • 17. For more information on data centers, please contact us. Contact Us Jon D. Kerner Partner ScottMadden, Inc. Ten Piedmont Center Suite 805 Atlanta, GA 30305 Phone: 678-702-8346 Mobile: 904-718-8935 jkerner@scottmadden.com 16