Power Electronical provides Transformer Oil Testing and Oil Analysis services. Our lab is NABL accreditated, and provide IEC/IS/ASTM standard test services.
1. POWER ELECTRONICAL
Oil Testing Experts
http://www.powerelectronical.com/
Transformer Oil Testing
Oil suffers from electrical and mechanical stresses while a transformer is in operation. In addition there are contaminations caused due
to chemical interactions with windings and other solid insulations, catalyzed by high operating temperature. As a result the original
chemical properties of Transformer Oil changes gradually, rendering it ineffective for its intended purpose after many years. Hence this
oil has to be periodically tested to ascertain its basic electrical properties, and make sure it is suitable for further use or necessary
actions like filtration/regeneration has to be done.
Power Electronical
Transformer Oil Testing Laboratory (TOTL)
PE‐TOTL is India’s leading private laboratory for Transformer Oil testing. It is
located in the same premises as the HQ office, and this allows for constant
supervision and monitoring of test methods and testing procedures, and
constant upgradation to higher standards of testing. The NABL accreditation
for this test laboratory is the icing on the cake, and allows us to certify our
test results with authority that very few laboratories across India can match.
The testing is usually done as per IEC 17025:2000, but we have the capability
to test as per the customer’s requirements for any other local standard also.
Add the low turnaround time for sample testing, the precise and accurate
results, and the record maintenance; the high demand from our customers is
making us almost approach the end of spare capacity. The plan hence is to
replicate the high standards of Oil testing and set up a couple more of
regional laboratories across India and Mid‐East.
Tests profile
Sr. Tests IEC ASTM IS
1 Color & Appearance ISO 2049 D‐1524 IS 335
2 Breakdown Voltage IEC 60156 D‐877 IS 6792
3 Water Content IEC 60814 D‐1533 B IS 13567
4 Acidity (Neutralization Value) IEC 62021 D‐974 IS 1448 [P‐2]
5 Dielectric Dissipation Factor IS 6262
IEC 60247 D‐924
6 Resistivity IS 6103
7 Sediments & Sludge IEC 61125 D‐1524 IS 1866
8 Interfacial Tension ISO 6295 D‐971 IS 6104
9 Flash Point IEC 2719 D‐92 IS 1448
10 Pour Point ISO 3016 D‐97 IS 1448
11 Density IEC 60814 D‐1298 IS 1448
12 Kinematic Viscosity ISO 3104 D‐445 IS 1448 [P‐25]
13 Dissolved Gas Analysis NA D‐3612‐A IS 9434
15 Furan Analysis IEC 61198 D‐5837 ‐‐‐
D-24, Classic Indl Premises,
Timely & Correct Diagnosis saves efforts & money MIDC Ambad, Nasik – 422010, MH, India.
Tel : +91 253 6602387
Trust the experts!! Fax : +91 253 6602388
Email : contact@powerelectronical.com
2. POWER ELECTRONICAL
Oil Testing Experts
http://www.powerelectronical.com/
NABL Accreditation
Power Electronical’s TOTL has been certified for Transformer Oil
testing by NABL (T‐1424). It is only one of the few private labs in
India to be accorded this status. The NABL accreditation allows our
customers to be able to compare and use the test readings to a
scale comparable with National test laboratories. It is also a proof
of our unswerving commitment to highest levels of quality
standards for Oil testing. Under NABL, the following parameters are
under periodic scrutiny, thus allowing our customers to work
peacefully while we work for them 24X7
‐ our facilities
‐ test procedurals, and,
‐ record maintenance
ISO 9001 : 2000 Certification
We believe International systems accreditation contributes to our
better working and better quality of service for our customers.
Power Electronical’s TOTAL has been certified ISO 9001:2000
compliant for its procedures and Quality management systems
Transformer Oil testing by TUV SUD.
Certificate Regn No – 99 100 03494 valid until 23 Jan 2011
These certificates only prove our systems, calibration and testing
standards. But, it is our response system and the services we
render to our customers, that allows us to scale higher echelons of
reputation.
D-24, Classic Indl Premises,
Timely & Correct Diagnosis saves efforts & money MIDC Ambad, Nasik – 422010, MH, India.
Tel : +91 253 6602387
Trust the experts!! Fax : +91 253 6602388
Email : contact@powerelectronical.com
3. POWER ELECTRONICAL
Oil Testing Experts
http://www.powerelectronical.com/
Condition Monitoring Services
Testing is only half the work done….without correct and accurate analysis, it serves no worthwhile purpose. Our engineers and
laboratory staff are well equipped with knowledge and experience to be able to analyze the results and predict any kind of rapid
degradation of Oil parameters, or advise residual life expectancy or fault interpretation. We follow it up with site visit and testing of
other parameters of your equipment, to confirm the assessment, and help the customer take preventive and corrective measures
well within time. A maintenance contract signed with us for all your critical equipment gives you complete peace of mind, because
we look after them 24X7 thereafter, including scheduled and emergency visits.
Convenience with TOTL association
• Test results provided within 3 working days from sample receipt
• Urgent testing provision at additional 25% charge. Test result provided within 1 working day
• Logistic control and handling may be done by TOTL, on customer’s request
• All tests done under controlled temperature and humidity, to maintain test integrity
• All testing data records maintained for a period of 6 years
• Statistical trending & analysis, on request
• Experienced persons handling test operations, on continual basis since past 5 years
• Single point communication window established for all customers
• Volume discount available to special customers with committed volumes
• Credit limits for special customers, post 6 months of association
Sample Procedure & Costs
• Sampling will be done by our person. Travelling to & fro charges from Nasik will be to customer’s account.
• Customer can issue sampling bottles from us, and do their sampling themselves. To & fro logistics cost of bottles, including
taxes/custom levies will be to customer’s account.
• Sampling bottle may be provided on request. Deposit per bottle is 7500 INR (150US$), on refundable basis.
• Test results will be provided by email. For any paper copy requirement, shipping within India is free, but outside India is to
customer’s account.
Contact PE‐TOTL for world class Transformer Oil Testing services,
exclusively at TOTL@powerelectronical.com
Note – Power Electronical reserves the right to change service specifications for continual improvement. Please order a fresh copy of service contract from
contact@powerelectronical.com, before placing new orders. Jurisdiction limits within territory of Republic of India only.
Our other Products are –
• Automatic Cap & Tan Delta test system 10kV / 12kV • Automatic Oil Resistivity & DF tester
• Manual C&DF test system 12kV • Insulation Testers (10M to 15T, 2% accuracy)
• Auto Oil Breakdown Voltage Tester 80kV / 100kV • High Voltage Breakdown testers (10kV‐50kV)
• Motorised Oil BDV set 0‐100kV • SF6 Gas filled Standard Capacitors (upto 1000kV)
D-24, Classic Indl Premises,
Timely & Correct Diagnosis saves efforts & money MIDC Ambad, Nasik – 422010, MH, India.
Tel : +91 253 6602387
Trust the experts!! Fax : +91 253 6602388
Email : contact@powerelectronical.com