1.
2. By
A . S. Powar & M . S . Salunkhe
Guide
Dr. B. P. Ladgaonkar
Prof. S. K.Tilekar
VLSI Design and Research Center
Post Graduate Department of Electronics
Shankarrao Mohite Mahavidyalaya, Akluj
Tal - Malshiras , Dist. - Solapur – 413 101
3. 1. Introduction
A) Origin of the Problem
B) Aim & Objectives
2. Designing of the System
Hardware Co-design
3. Result and Discussion
4. Conclusion
4. It is found that, the humidity, CO2 in the polyhouse is not
measured precisely with the help of unskilled person.
This may adversely affect the yield of the crops.
Therefore, it is found that this agriculture field is mostly
demanding the sophisticated instrument to monitor the
parameters of polyhouse.
Hence considering this fact and the social demands, it is
proposed to develop an electronic system to measure the
environmental parameters of polyhouse.
5. To study the architectural details of PSoC1.
To study the PSoC designer IDE.
To configure the hardware using PSoC1.
Co development of necessary software.
Implementation of the system.
Interpretation of result.
6. Polyhouse or Green house provides a controlled and
favourable environment for the crops to grow in all
seasons. The important parameters are:
Humidity
CO2
14. Overall chemical reaction:Li2CO3 + 2Na + = Na2O + 2Li + + CO2
EMF = Ec - (R x T) / (2F) ln (P(CO2))
Where, P(CO2) - CO2 partial Pressure, Ec - Constant Volume, R - Gas
Constant volume, T - Absolute Temperature (K), F- Faraday constant
15. PSoC Device Features:
• Configurable Analog Blocks
Implement ADCs, DACs, filters,
amplifiers,
comparators, etc.
• Configurable Digital Blocks
Implement timers, counters, PWMs,
UART, SPI, IrDA, etc.
• 4KB to 32KB of Flash memory for
program storage
• 256B to 2KB of SRAM for data storage
• M8C Microcontroller: 4 Million
Instructions Per Sec
16. Inputs :
Each pin can sink 25mA
Programmable filters
Flexible sensor interface I/O
3 types of ADCs, up to 4
Processing :
Fast M8 Microcontroller Core
Multiply Accumulate
Outputs :
Each pin can source 10mA
Up to 16 PWMs, Timers, Counters
Up to 9-bit DACs, 14-bit ADCs
Support Functions :
EEPROM
Sleep Options
Watch Dog Timer
Low voltage detect
17.
18.
19.
20.
21.
22.
23.
24. i = V/R
Q = CV
I average = Q/T = Qfs = CVfs
R equivalent = V/I average = 1/Cfs
25.
26. Determine system requirements
Choose User Modules
Place User Modules
Set global and User Module parameters
Define the pin-out for the device
Generate the application
Review generated code
Demonstrate working configuration
36. B) Application programme routine
A) Boot programme algorithm Void main()
{
Start system timers;
Execute boot program: Initialise application specific
--initialise general purpose resources; modules;
--configure application specific Initialise global variables;
modules; Initialise application specific
--initialise run time environment; channels;
--disable interrupt; Enable interrupts;
call main application routine; While(1)
{
Wait for events(Enabled interrupts);
Read values from input channels;
Execute control
procedure & compute
actuation data;
output actuation data to output
channels;
}
}
37. Start
Initialization of
all modules
Get ADC reading
SoftwareHumidity for Flow Of
Design
Calibrate data
Our System
Convert in ASCII
Display reading
Get reading for CO2
If
count<0x65(
Yes 200mv) No
Display as Undetected Display as Detected
STOP
38. A
Initialize ADC1
NO
When ADC 1
Data Available
YES
Calibrate the Data
Convert in to ASCII
Display
B
39. B
Initialize ADC2
When ADC
2 Data
Available
YES
If Count
<0x65(200m
v)
NO
Display as Display as
Undetected Detected
Return Return
48. System is designed for measurement of humidity and CO2 gas
The humidity observations shown by the system are highly reliable and
precise. Moreover, the presence of CO2 gas is also exhibited by the
present system.
System works successfully and gives the data regarding environmental
parameters very precisely.
49. Particularly for measurement of carbon
dioxide (CO2) gas concentration, the
calibration in the respective units is
required. However, presently due to
unavailability of CO2 gas chamber the
calibration of carbon dioxide gas
concentration is left as future work.