SlideShare uma empresa Scribd logo
1 de 22
Baixar para ler offline
1
TECHNICAL COMMUNICATION No. TC1319 Ed. 01
OmniPCX Enterprise Nb of pages : 22 Date : 05 March 2010
URGENT
NOT URGENT TEMPORARY PERMANENT
SUBJECT: INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26
SOFTWARE
CONTENTS
1. INTRODUCTION..........................................................................3
2. RECOMMENDATIONS BEFORE THE INSTALLATION .....................3
2.1. PC requirements and OS compatibility...................................................... 3
2.2. Before beginning the installation.............................................................. 3
3. RECOMMENDATIONS BEFORE THE UPGRADE .............................4
4. INSTALLATION ............................................................................4
5. MANAGEMENT............................................................................8
5.1. Other Servers detection ............................................................................ 8
5.2. Installing a patch ...................................................................................... 9
5.3. Installing Linux on an inactive partition .................................................. 10
5.4. Standard installation of a complete version ............................................ 11
5.5. Installing the GD/GA/rGD/GD3/INTIP3 binary....................................... 16
6. UNINSTALLING THE PC INSTALLER............................................19
7. EXTENDED FEATURES ................................................................21
8. CORRECTIONS ..........................................................................21
9. KNOWN RESTRICTIONS ............................................................21
2
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 3 TC1319
1. INTRODUCTION
The software OmniPCX Enterprise PC Installer allows to install versions, patches, Linux on inactive
partition and GD/GA/rGD/GD3/INTIP3 binary on an OmniPCX Enterprise Releases 5.1.x, 6.x and
higher.
2. RECOMMENDATIONS BEFORE THE INSTALLATION
2.1. PC requirements and OS compatibility
− 20 MB disk space.
− IP Network Configuration:
network board,
TCP/IP protocol,
IP static address.
− Windows NT4 SP6, Windows 2000, Windows XP.
From version V2.19 the OmniPCX Enterprise PC Installer software is not
compatible with Windows 98. When the installation begins? an information
window indicates that the software cannot be installed on this operating system.
CAUTION
If a Firewall is available on the server PC, the OmniPCX Enterprise PC Installer application cannot
operate as long as the filtering rules of firewall have not been changed to allow the application to
receive packets on 67/UDP (BOOTP/DHCP), 69/UDP, 20/TCP and 21/TCP (FTP) ports from any
system on the subnetwork of the PC.
If an other application of DHCP, TFTP or FTP server type is installed on the server PC, the associated
server(s) must not be started.
2.2. Before beginning the installation
Before installing the software:
− a local administrator session needs to be run to have the good rights,
− you should stop all the programs that are running.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 4 Ed. 01 / 05 March 2010
3. RECOMMENDATIONS BEFORE THE UPGRADE
Before upgrading the software, uninstall the existing version ; refer to section 6 then install the new
one using setup.exe ; refer to section 4 .
4. INSTALLATION
The installation of the software OmniPCX Enterprise PC Installer is done with InstallShield with
the help of setup.exe.
In this example, the installation is done in the default directory
C:/Program Files/Alcatel/OmniPCX Enterprise PC Installer
− Select the CD-ROM of the software OmniPCX Enterprise PC Installer or the drive on which the
OmniPCX Enterprise version is located (under repertory
/dhs3mgr/"version or patch"/pcmao/boot_res/pcinstall)
− Run setup exe . The following window is displayed:
− Select the language of the installation, French or English and click on OK.
The following window is displayed:
followed by this Welcome window:
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 5 TC1319
− Click on Next.
The following window is displayed:
− Click on Next.
Note
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 6 Ed. 01 / 05 March 2010
If the size of PATH variable in environment parameter is higher than 250 characters a warning
window appears, click on OK.
A new information window shows modifications of the value in PATH system variable (delete
several same variables Value), click on OK.
The following window is displayed:
During the installation a warning window can appear:
− Click on OK and validate the automatic start of "Computer Browser" windows service at the end
of software installation.
At the end of installation, the following window is displayed:
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 7 TC1319
At the end of the installation process you can view the README.txt file that contains the
delivery note with the list of new corrections, paragraph 7 & 8.
− Click on Finish.
An icon OmniPCX Enterprise PC Installer is created on the desktop and an OmniPCX
Enterprise PC Installer entry in the Start/OmniPCX Enterprise PC Installer
menu.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 8 Ed. 01 / 05 March 2010
5. MANAGEMENT
5.1. Other Servers detection
At startup a test detecting other DHCP, FTP or TFTP server is completed on the PC Server. The user is
informed of the presence of an active server and he is asked to inactivate manually the service. The
following window is displayed on the screen:
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 9 TC1319
5.2. Installing a patch
The installation of a patch is carried out with the OmniPCX Enterprise PC Installer and swinst
software on the OmniPCX Enterprise.
− On the desktop, double click on the icon OmniPCX Enterprise PC Installer. The following
window is displayed:
− In the menu Preferences, select the drive that contains the patch.
− In the field Installation type, select the type of installation to "Call handling or
patch only".
Note
A TFTP server and a FTP server are running during all the installation of the patch and are stopped
only when the window OmniPCX Enterprise PC Installer is closed.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 10 Ed. 01 / 05 March 2010
5.3. Installing Linux on an inactive partition
The installation of Linux on an inactive partition is carried out with the OmniPCX Enterprise PC
Installer and swinst software on the OmniPCX Enterprise.
− Open the application OmniPCX Enterprise PC Installer as described in section § 5.2 .
− In the menu Preferences, select the drive that contains the PABX version.
− In the field Installation type, select the type of installation Linux on inactive
partition
Note
A FTP server is running during all the installation of the patch and is stopped only when the window
OmniPCX Enterprise PC Installer is closed.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 11 TC1319
5.4. Standard installation of a complete version
The standard installation of a complete version is carried out with:
− the OmniPCX Enterprise PC Installer software and,
− either CPU bios standard installation menu of a A4400 Call Server or automatically after a
network boot of an Alize, Appliance Server, Blade Server or CS-2.
Procedure
− Open the application OmniPCX Enterprise PC Installer as described in section § 5.2 .
− In the menu Preferences, select the drive that contains the PABX version to be installed.
− In the field Installation type, select the type of installation Linux + Call_handling
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 12 Ed. 01 / 05 March 2010
− The window Parameters Installation is displayed:
− In Call Server Type, select the type of the CPU to install (Alize, 4400, Appliance_server,
Blade Server or CS-2).
− In Call handling version, select the complete version or the complete version+
patch,
− In Country, select the country.
− In Installation type, select Standard installation.
− In Network type, select the type of installation to Direct cable.
− In Network Interface, select the network board interface used.
− In Client IP Address, the IP address allocated to the Call Server is displayed.
− In Ethernet Address, don’t set the Ethernet address (_not needed_) of the CPU.
− Click on Apply and the following window is displayed with the greyed button Apply.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 13 TC1319
− On Call Server V24 configuration port:
For Alize, Appliance Server, Blade Server or CS-2 Call Server
If the no software version is loaded on the server, the Bios default parameters will force the
server to reboot continuously on its Ethernet interface.
If a software version is loaded on the server, use following process to force the boot on the
Ethernet interface:
♦ Login as root account.
♦ Launch grubboot ETHER then shutdown –r now command.
Standard installation begins after the Call Server performs a network boot.
For CPU7 Call Server
Two methods of installation are possible, the Alize method or 4400 method, see Note 2.
If the no software version is loaded on the server, the Bios default parameters will force the
CPU7 to reboot on its Ethernet interface using the Alize method of installation.
If a software version is loaded on the server, use following process to force the boot on the
Ethernet interface using the Alize method of installation:
♦ Login as root account.
♦ Launch grubboot ETHER then shutdown –r now command.
Standard installation begins after the Call Server performs a network boot.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 14 Ed. 01 / 05 March 2010
For A4400 (CPU5, CPU6, CPU7 with 4400 method) Call Server
During the boot process it is mandatory to enter the Bios menu to force the boot on the
Ethernet using the following process:
♦ From CPU5 or CPU6 bios boot menu, select 5 - Booting from Ethernet
Network or from CPU7 BIOS Loader Menu, select 03 - Load From Ethernet
(4400 method) ; see Note 2.
♦ Select Standard Installation.
♦ Enter the complete version (+ patch if necessary) and the country.
♦ Enter the Linux version preceded by % (Linux version can be read under
dhs3mgrversionpcmaoboot_resbootplinux)
Boot
Boot Menu :
1 - Booting From Floppy #0
2 - Booting From Floppy #1
3 - Booting From Hard Disk #0
4 - Booting From Hard Disk #1
5 - Booting From Ethernet Network
6 - Default Boot Sequence
> 5
Booting From Ethernet Network
Updating bootinfo
ACT4400 specific INSTALLATION data input:
=========================================
Standard installation (y/n, default is y) ? : y
TEL version ? : f16023c.ca
Phase 1: address determination and bootfile selection
=====================================================
NB: All parameters below are optional.
Default internet Address : *** Unknown ***
New Internet Address :
Name of default BOOTP/TFTP server : *** Unknown ***
Name of a new BOOTP/TFTP server :
Default loaded file :
New loaded file : %15.0
BOOTP request in progress .....................
Note 1
In addition of TFTP and FTP servers, a DHCP server is activated during a standard installation and
stops only when the window Installation Parameters is closed.
Closing the application OmniPCX Enterprise PC Installer stops the three servers TFTP, FTP and
DHCP.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 15 TC1319
Note 2: Case for CPU7
The standard installation of a complete version on a CPU7 Call Server can be done indifferently with
the CPU 4400 or CPU Alize methods.
This choice is done in the BIOS Loader Menu accessible with the commands Ctrl B and Ctrl
i. The menu offers two methods of loading from Ethernet, the Alize method or the CPU 4400 method.
BIOS Loader Menu
01 - Load From Hdisk #0
02 - Load From Ethernet (Alize method)
03 - Load From Ethernet (4400 method)
04 - Load From Hdisk #0 and Bootp
05 - MAC Address
06 - PCMS id
07 - System informations
08 - Set interface KENDIN to default(auto-nego)
09 - Interface KENDIN state
10 - Set Interface KENDIN
11 - Ethernet embedded interface state
12 - Full Option Menu
13 - Reset System
CPU7 >
The configuration of the Installation parameters of the OmniPCX Enterprise PC Installer
application should be adapted to the loading method chosen.
Option: 02 - Load From Ethernet (Alize method)
Preliminary you have to select the Call Server type: Alize, the Call handling version and the
country in the Installation parameters window of the OmniPCX Enterprise PC Installer.
Option: 03 - Load from Ethernet (4400 method)
Preliminary you have to select the Call Server type: A4400 in the Installation parameters
window of the OmniPCX Enterprise PC Installer.
The other fields are not accessible because they are selected through BIOS such as a CPU5 or CPU6
loading.
Note 3: Bios access for CS-2
For CS boards, the Bios can be accessed at startup using the commands Ctrl+B and Ctrl+i.
For the CS-2 boards, the Bios MUST only be accessed at startup using the single command Ctrl+B.
It is strickly forbidden to add the command Ctrl+i. For more details consult technical
communication TC1212 CS-2 board introduction.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 16 Ed. 01 / 05 March 2010
5.5. Installing the GD/GA/rGD/GD3/INTIP3 binary
Installation of a GD/GA/rGD/GD3/INTIP3 binary is only done with the OmniPCX Enterprise PC
Installer and a GD/GA/rGD/GD3/INTIP3 which operates a network boot on the PC server.
− Open the application OmniPCX Enterprise PC Installer as described in section § 5.2 .
− In the menu Preferences, select the drive that contains the PABX version to be installed.
− The version must have the directories:
• /dhs3mgr/"version"/pcmao/boot_res/DHS3bin/downbin/emg which contains
the GD/GA/rGD binaries.
• /dhs3mgr/"version"/pcmao/boot_res/DHS3bin/downbin/mg3 which contains
the GD3 binaries.
• /dhs3mgr/"version"/pcmao/boot_res/DHS3bin/downbin/intip3 which
contains the INTIP3 binaries.
− In the field Installation type, select the type of installation GD/GA/rGD/GD3/INTIP3
binary
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 17 TC1319
− The Installation Parameters window is displayed:
− In Media Gateway board designation, select the board type (GD/GA or rGD).
− In Media Gateway binary versions, select the version.
− In Network type, select the type of installation to Direct cable.
− In Network Interface, select the network board interface used.
− In IP Address, the IP address allocated to the GD/GA is displayed.
− In Ethernet Address don’t set the Ethernet address (_not needed_) of the GD/GA.
− Click on Apply and the following window is displayed with the greyed button Apply.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 18 Ed. 01 / 05 March 2010
Note
In addition of TFTP server, a DHCP server is activated during installation of a
GD/GA/rGD/GD3/INTIP3 binaries and stops only when the Installation Parameters window
is closed.
Closing the application OmniPCX Enterprise PC Installer stops the two servers TFTP and DHCP.
The complete process for reformatting and reloading Flash NAND memory of
GD/GA/rGD/GD3/INTIP3 is explained in technical communication TC0521 Reformatting and
reloading the e-MGD Nand Flash with PC Installer.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 19 TC1319
6. UNINSTALLING THE PC INSTALLER
To uninstall the software on the PC, follow the procedure below.
− Close all the applications that are used.
− In the taskbar, click on Start/Programs/OmniPCX Enterprise PC Installer/
Uninstall OmniPCX Enterprise PC Installer.
The following window is displayed:
− Confirm the deletion: click on Yes.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 20 Ed. 01 / 05 March 2010
The following window is displayed:
− At the end of the uninstallation, a message indicates that the uninstallation is completed, but
some elements could not be removed: A program will delete automatically these elements by
clicking on OK.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
Ed. 01 / 05 March 2010 21 TC1319
7. EXTENDED FEATURES
− From version 2.23, PC Installer supports a new country K2, used for the BiCS installation.
− From version 2.24, PC Installer supports a new client: CS-2.
− From version 2.26, PC Installer supports a new client: GD3, INTIP3.
8. CORRECTIONS
crms00197834 PC Installer 2.26: NGP PC Installer - INTIP3 Picklist NOK.
Abstract: Do the desired modifications for the INTIP3 pick list to display the required
version number.
crms00182355 PC Installer 2.25 : NGP PC Installer.
Abstract: Make Enhance PC installer to support with GD3, INTIP3A, INTIP3B, GA3
boards.
crms00043284 PC Installer 2.25: Linux 55.0: Installation Complete Not OK.
Abstract: Remove: Linux+call handling"/"Reload Linux" menu in PC Installer.
crms00159859 PC Installer 2.24: Add CS-2 to the pick list.
Abstract: Addition of CS-2 to the dropdown list and generation of of the dhcpd.conf
file for the requested configuration.
9. KNOWN RESTRICTIONS
No known restriction.
OmniPCX Enterprise
INSTALLING AND USING THE OmniPCX
Enterprise PC INSTALLER V2.26 SOFTWARE
TC1319 22 Ed. 01 / 05 March 2010

Mais conteúdo relacionado

Mais procurados

Asterisk sach asterisk tieng viet
Asterisk sach asterisk tieng vietAsterisk sach asterisk tieng viet
Asterisk sach asterisk tieng viet
laonap166
 
Global Payment System- Reference Architecture
Global Payment System- Reference ArchitectureGlobal Payment System- Reference Architecture
Global Payment System- Reference Architecture
Ramadas MV
 
Khái niệm thông tin và dữ liệu
Khái niệm thông tin và dữ liệuKhái niệm thông tin và dữ liệu
Khái niệm thông tin và dữ liệu
minhhai07b08
 
Hệ điều hành (chương 5)
Hệ điều hành (chương 5)Hệ điều hành (chương 5)
Hệ điều hành (chương 5)
realpotter
 
PHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNG
PHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNGPHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNG
PHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNG
Thùy Linh
 
Chuyển mạch nhãn đa giao thức mpls
Chuyển mạch nhãn đa giao thức mplsChuyển mạch nhãn đa giao thức mpls
Chuyển mạch nhãn đa giao thức mpls
successnguyen86
 

Mais procurados (20)

Giải pháp quản trị và vận hành hệ thống CNTT theo tiêu chuẩn ITIL/ ISO 20000
Giải pháp quản trị và vận hành hệ thống CNTT theo tiêu chuẩn ITIL/ ISO 20000Giải pháp quản trị và vận hành hệ thống CNTT theo tiêu chuẩn ITIL/ ISO 20000
Giải pháp quản trị và vận hành hệ thống CNTT theo tiêu chuẩn ITIL/ ISO 20000
 
Tìm hiểu về cảm biến nhiệt độ
Tìm hiểu về cảm biến nhiệt độTìm hiểu về cảm biến nhiệt độ
Tìm hiểu về cảm biến nhiệt độ
 
VoIP
VoIPVoIP
VoIP
 
Tài liệu Full VOIP
Tài liệu Full VOIPTài liệu Full VOIP
Tài liệu Full VOIP
 
Asterisk sach asterisk tieng viet
Asterisk sach asterisk tieng vietAsterisk sach asterisk tieng viet
Asterisk sach asterisk tieng viet
 
Huong dan ghost hdh linux qua g4 l
Huong dan ghost hdh linux qua g4 lHuong dan ghost hdh linux qua g4 l
Huong dan ghost hdh linux qua g4 l
 
Global Payment System- Reference Architecture
Global Payment System- Reference ArchitectureGlobal Payment System- Reference Architecture
Global Payment System- Reference Architecture
 
Khái niệm thông tin và dữ liệu
Khái niệm thông tin và dữ liệuKhái niệm thông tin và dữ liệu
Khái niệm thông tin và dữ liệu
 
Đề tài: Nghiệm hữu hiệu và điều kiện cho bài toán cân bằng vectơ
Đề tài: Nghiệm hữu hiệu và điều kiện cho bài toán cân bằng vectơĐề tài: Nghiệm hữu hiệu và điều kiện cho bài toán cân bằng vectơ
Đề tài: Nghiệm hữu hiệu và điều kiện cho bài toán cân bằng vectơ
 
Hệ điều hành (chương 5)
Hệ điều hành (chương 5)Hệ điều hành (chương 5)
Hệ điều hành (chương 5)
 
Thiết kế mạng cảm biến không dây cho giám sát sức khỏe, HAY
Thiết kế mạng cảm biến không dây cho giám sát sức khỏe, HAYThiết kế mạng cảm biến không dây cho giám sát sức khỏe, HAY
Thiết kế mạng cảm biến không dây cho giám sát sức khỏe, HAY
 
Mau bao cao project 1
Mau bao cao project 1Mau bao cao project 1
Mau bao cao project 1
 
Luận văn: Thiết kế hệ thống tưới cây tự động, HAY
Luận văn: Thiết kế hệ thống tưới cây tự động, HAYLuận văn: Thiết kế hệ thống tưới cây tự động, HAY
Luận văn: Thiết kế hệ thống tưới cây tự động, HAY
 
Qlda
QldaQlda
Qlda
 
PHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNG
PHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNGPHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNG
PHÂN TÍCH THIẾT KẾ HỆ THỐNG BÁN HÀNG QUA MẠNG
 
Đề tài: Ứng dụng Iot giám sát mức tiêu thụ điện – nước, HAY
Đề tài: Ứng dụng Iot giám sát mức tiêu thụ điện – nước, HAYĐề tài: Ứng dụng Iot giám sát mức tiêu thụ điện – nước, HAY
Đề tài: Ứng dụng Iot giám sát mức tiêu thụ điện – nước, HAY
 
[BTL] Cảm biến nhiệt độ
[BTL] Cảm biến nhiệt độ[BTL] Cảm biến nhiệt độ
[BTL] Cảm biến nhiệt độ
 
Chuyển mạch nhãn đa giao thức mpls
Chuyển mạch nhãn đa giao thức mplsChuyển mạch nhãn đa giao thức mpls
Chuyển mạch nhãn đa giao thức mpls
 
Ask fsk-psk-qpsk-qam-modulation-demolation
Ask fsk-psk-qpsk-qam-modulation-demolationAsk fsk-psk-qpsk-qam-modulation-demolation
Ask fsk-psk-qpsk-qam-modulation-demolation
 
Dân số việt nam 2015 phan 1
Dân số việt nam 2015 phan 1Dân số việt nam 2015 phan 1
Dân số việt nam 2015 phan 1
 

Destaque

даниленкороман+фитнесзал+предприниматели
даниленкороман+фитнесзал+предпринимателиданиленкороман+фитнесзал+предприниматели
даниленкороман+фитнесзал+предприниматели
Роман Даниленко
 
3. Professional Certificate - MPM I
3. Professional Certificate - MPM I3. Professional Certificate - MPM I
3. Professional Certificate - MPM I
Poonam Sood
 
Drawing samples 1063, 1670, 1673, 1674 SolidWorks ACAD
Drawing samples 1063, 1670, 1673, 1674 SolidWorks ACADDrawing samples 1063, 1670, 1673, 1674 SolidWorks ACAD
Drawing samples 1063, 1670, 1673, 1674 SolidWorks ACAD
Gary mccoy
 
Architecture d'entreprise
Architecture d'entrepriseArchitecture d'entreprise
Architecture d'entreprise
Rational_France
 

Destaque (11)

hoveddokument
hoveddokumenthoveddokument
hoveddokument
 
даниленкороман+фитнесзал+предприниматели
даниленкороман+фитнесзал+предпринимателиданиленкороман+фитнесзал+предприниматели
даниленкороман+фитнесзал+предприниматели
 
Etapas
EtapasEtapas
Etapas
 
3. Professional Certificate - MPM I
3. Professional Certificate - MPM I3. Professional Certificate - MPM I
3. Professional Certificate - MPM I
 
hIgh 5 Mon process d’innovation
hIgh 5   Mon process d’innovationhIgh 5   Mon process d’innovation
hIgh 5 Mon process d’innovation
 
Food for All on a Changing Planet
Food for All on a Changing PlanetFood for All on a Changing Planet
Food for All on a Changing Planet
 
Drawing samples 1063, 1670, 1673, 1674 SolidWorks ACAD
Drawing samples 1063, 1670, 1673, 1674 SolidWorks ACADDrawing samples 1063, 1670, 1673, 1674 SolidWorks ACAD
Drawing samples 1063, 1670, 1673, 1674 SolidWorks ACAD
 
Architecture d'entreprise
Architecture d'entrepriseArchitecture d'entreprise
Architecture d'entreprise
 
Grape wine introduction for the class-ok
Grape wine  introduction for the class-okGrape wine  introduction for the class-ok
Grape wine introduction for the class-ok
 
Architecture d' Entreprise - AE Navigateur
Architecture d' Entreprise  - AE NavigateurArchitecture d' Entreprise  - AE Navigateur
Architecture d' Entreprise - AE Navigateur
 
Sistemas Informaticos
Sistemas InformaticosSistemas Informaticos
Sistemas Informaticos
 

Semelhante a Installing and using the omni pcx enterprise pc installer v2.26 software

SOP - 2013 Server Build
SOP - 2013 Server BuildSOP - 2013 Server Build
SOP - 2013 Server Build
Robert Jones
 
Motorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guideMotorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guide
Advantec Distribution
 
Paper less-pro-sb-quick-start-guide
Paper less-pro-sb-quick-start-guidePaper less-pro-sb-quick-start-guide
Paper less-pro-sb-quick-start-guide
rb pn
 
Ovms ops manager_admin
Ovms ops manager_adminOvms ops manager_admin
Ovms ops manager_admin
sati1981
 
M vci esi-2.0_sfp_installation_guide
M vci esi-2.0_sfp_installation_guideM vci esi-2.0_sfp_installation_guide
M vci esi-2.0_sfp_installation_guide
Jordy Alva Guarniz
 
Motorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guideMotorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guide
Advantec Distribution
 

Semelhante a Installing and using the omni pcx enterprise pc installer v2.26 software (20)

Pws altboot
Pws altbootPws altboot
Pws altboot
 
Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...
Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...
Fault tolerance ease of setup comparison: NEC hardware-based FT vs. software-...
 
manual vvtk camera_st7501
manual vvtk camera_st7501manual vvtk camera_st7501
manual vvtk camera_st7501
 
SOP - 2013 Server Build
SOP - 2013 Server BuildSOP - 2013 Server Build
SOP - 2013 Server Build
 
Motorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guideMotorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guide
 
KB Article 1-FINAL
KB Article 1-FINALKB Article 1-FINAL
KB Article 1-FINAL
 
creative 1130
creative 1130creative 1130
creative 1130
 
Paper less-pro-sb-quick-start-guide
Paper less-pro-sb-quick-start-guidePaper less-pro-sb-quick-start-guide
Paper less-pro-sb-quick-start-guide
 
Bluetooth quick start_guide / Controlanything India
Bluetooth quick start_guide / Controlanything IndiaBluetooth quick start_guide / Controlanything India
Bluetooth quick start_guide / Controlanything India
 
AltiGen Max In Sight Manual
AltiGen Max In Sight  ManualAltiGen Max In Sight  Manual
AltiGen Max In Sight Manual
 
Eding_CNC_Software_installation_manual.pdf
Eding_CNC_Software_installation_manual.pdfEding_CNC_Software_installation_manual.pdf
Eding_CNC_Software_installation_manual.pdf
 
Project Pt1
Project Pt1Project Pt1
Project Pt1
 
Ovms ops manager_admin
Ovms ops manager_adminOvms ops manager_admin
Ovms ops manager_admin
 
Esm rel notes_6.0cp1
Esm rel notes_6.0cp1Esm rel notes_6.0cp1
Esm rel notes_6.0cp1
 
M vci esi-2.0_sfp_installation_guide
M vci esi-2.0_sfp_installation_guideM vci esi-2.0_sfp_installation_guide
M vci esi-2.0_sfp_installation_guide
 
Axe027
Axe027Axe027
Axe027
 
Motorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guideMotorola air defense mobile 6.1 install guide
Motorola air defense mobile 6.1 install guide
 
1 K E Y2
1 K E Y21 K E Y2
1 K E Y2
 
RepSM Model Import Connector v5.2.7.6581.0 Configuration Guide for ArcSight E...
RepSM Model Import Connector v5.2.7.6581.0 Configuration Guide for ArcSight E...RepSM Model Import Connector v5.2.7.6581.0 Configuration Guide for ArcSight E...
RepSM Model Import Connector v5.2.7.6581.0 Configuration Guide for ArcSight E...
 
CCTV Nu client user_manual
CCTV Nu client user_manualCCTV Nu client user_manual
CCTV Nu client user_manual
 

Último

FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 

Último (20)

The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 

Installing and using the omni pcx enterprise pc installer v2.26 software

  • 1. 1 TECHNICAL COMMUNICATION No. TC1319 Ed. 01 OmniPCX Enterprise Nb of pages : 22 Date : 05 March 2010 URGENT NOT URGENT TEMPORARY PERMANENT SUBJECT: INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE CONTENTS 1. INTRODUCTION..........................................................................3 2. RECOMMENDATIONS BEFORE THE INSTALLATION .....................3 2.1. PC requirements and OS compatibility...................................................... 3 2.2. Before beginning the installation.............................................................. 3 3. RECOMMENDATIONS BEFORE THE UPGRADE .............................4 4. INSTALLATION ............................................................................4 5. MANAGEMENT............................................................................8 5.1. Other Servers detection ............................................................................ 8 5.2. Installing a patch ...................................................................................... 9 5.3. Installing Linux on an inactive partition .................................................. 10 5.4. Standard installation of a complete version ............................................ 11 5.5. Installing the GD/GA/rGD/GD3/INTIP3 binary....................................... 16 6. UNINSTALLING THE PC INSTALLER............................................19 7. EXTENDED FEATURES ................................................................21 8. CORRECTIONS ..........................................................................21 9. KNOWN RESTRICTIONS ............................................................21
  • 2. 2
  • 3. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 3 TC1319 1. INTRODUCTION The software OmniPCX Enterprise PC Installer allows to install versions, patches, Linux on inactive partition and GD/GA/rGD/GD3/INTIP3 binary on an OmniPCX Enterprise Releases 5.1.x, 6.x and higher. 2. RECOMMENDATIONS BEFORE THE INSTALLATION 2.1. PC requirements and OS compatibility − 20 MB disk space. − IP Network Configuration: network board, TCP/IP protocol, IP static address. − Windows NT4 SP6, Windows 2000, Windows XP. From version V2.19 the OmniPCX Enterprise PC Installer software is not compatible with Windows 98. When the installation begins? an information window indicates that the software cannot be installed on this operating system. CAUTION If a Firewall is available on the server PC, the OmniPCX Enterprise PC Installer application cannot operate as long as the filtering rules of firewall have not been changed to allow the application to receive packets on 67/UDP (BOOTP/DHCP), 69/UDP, 20/TCP and 21/TCP (FTP) ports from any system on the subnetwork of the PC. If an other application of DHCP, TFTP or FTP server type is installed on the server PC, the associated server(s) must not be started. 2.2. Before beginning the installation Before installing the software: − a local administrator session needs to be run to have the good rights, − you should stop all the programs that are running.
  • 4. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 4 Ed. 01 / 05 March 2010 3. RECOMMENDATIONS BEFORE THE UPGRADE Before upgrading the software, uninstall the existing version ; refer to section 6 then install the new one using setup.exe ; refer to section 4 . 4. INSTALLATION The installation of the software OmniPCX Enterprise PC Installer is done with InstallShield with the help of setup.exe. In this example, the installation is done in the default directory C:/Program Files/Alcatel/OmniPCX Enterprise PC Installer − Select the CD-ROM of the software OmniPCX Enterprise PC Installer or the drive on which the OmniPCX Enterprise version is located (under repertory /dhs3mgr/"version or patch"/pcmao/boot_res/pcinstall) − Run setup exe . The following window is displayed: − Select the language of the installation, French or English and click on OK. The following window is displayed: followed by this Welcome window:
  • 5. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 5 TC1319 − Click on Next. The following window is displayed: − Click on Next. Note
  • 6. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 6 Ed. 01 / 05 March 2010 If the size of PATH variable in environment parameter is higher than 250 characters a warning window appears, click on OK. A new information window shows modifications of the value in PATH system variable (delete several same variables Value), click on OK. The following window is displayed: During the installation a warning window can appear: − Click on OK and validate the automatic start of "Computer Browser" windows service at the end of software installation. At the end of installation, the following window is displayed:
  • 7. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 7 TC1319 At the end of the installation process you can view the README.txt file that contains the delivery note with the list of new corrections, paragraph 7 & 8. − Click on Finish. An icon OmniPCX Enterprise PC Installer is created on the desktop and an OmniPCX Enterprise PC Installer entry in the Start/OmniPCX Enterprise PC Installer menu.
  • 8. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 8 Ed. 01 / 05 March 2010 5. MANAGEMENT 5.1. Other Servers detection At startup a test detecting other DHCP, FTP or TFTP server is completed on the PC Server. The user is informed of the presence of an active server and he is asked to inactivate manually the service. The following window is displayed on the screen:
  • 9. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 9 TC1319 5.2. Installing a patch The installation of a patch is carried out with the OmniPCX Enterprise PC Installer and swinst software on the OmniPCX Enterprise. − On the desktop, double click on the icon OmniPCX Enterprise PC Installer. The following window is displayed: − In the menu Preferences, select the drive that contains the patch. − In the field Installation type, select the type of installation to "Call handling or patch only". Note A TFTP server and a FTP server are running during all the installation of the patch and are stopped only when the window OmniPCX Enterprise PC Installer is closed.
  • 10. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 10 Ed. 01 / 05 March 2010 5.3. Installing Linux on an inactive partition The installation of Linux on an inactive partition is carried out with the OmniPCX Enterprise PC Installer and swinst software on the OmniPCX Enterprise. − Open the application OmniPCX Enterprise PC Installer as described in section § 5.2 . − In the menu Preferences, select the drive that contains the PABX version. − In the field Installation type, select the type of installation Linux on inactive partition Note A FTP server is running during all the installation of the patch and is stopped only when the window OmniPCX Enterprise PC Installer is closed.
  • 11. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 11 TC1319 5.4. Standard installation of a complete version The standard installation of a complete version is carried out with: − the OmniPCX Enterprise PC Installer software and, − either CPU bios standard installation menu of a A4400 Call Server or automatically after a network boot of an Alize, Appliance Server, Blade Server or CS-2. Procedure − Open the application OmniPCX Enterprise PC Installer as described in section § 5.2 . − In the menu Preferences, select the drive that contains the PABX version to be installed. − In the field Installation type, select the type of installation Linux + Call_handling
  • 12. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 12 Ed. 01 / 05 March 2010 − The window Parameters Installation is displayed: − In Call Server Type, select the type of the CPU to install (Alize, 4400, Appliance_server, Blade Server or CS-2). − In Call handling version, select the complete version or the complete version+ patch, − In Country, select the country. − In Installation type, select Standard installation. − In Network type, select the type of installation to Direct cable. − In Network Interface, select the network board interface used. − In Client IP Address, the IP address allocated to the Call Server is displayed. − In Ethernet Address, don’t set the Ethernet address (_not needed_) of the CPU. − Click on Apply and the following window is displayed with the greyed button Apply.
  • 13. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 13 TC1319 − On Call Server V24 configuration port: For Alize, Appliance Server, Blade Server or CS-2 Call Server If the no software version is loaded on the server, the Bios default parameters will force the server to reboot continuously on its Ethernet interface. If a software version is loaded on the server, use following process to force the boot on the Ethernet interface: ♦ Login as root account. ♦ Launch grubboot ETHER then shutdown –r now command. Standard installation begins after the Call Server performs a network boot. For CPU7 Call Server Two methods of installation are possible, the Alize method or 4400 method, see Note 2. If the no software version is loaded on the server, the Bios default parameters will force the CPU7 to reboot on its Ethernet interface using the Alize method of installation. If a software version is loaded on the server, use following process to force the boot on the Ethernet interface using the Alize method of installation: ♦ Login as root account. ♦ Launch grubboot ETHER then shutdown –r now command. Standard installation begins after the Call Server performs a network boot.
  • 14. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 14 Ed. 01 / 05 March 2010 For A4400 (CPU5, CPU6, CPU7 with 4400 method) Call Server During the boot process it is mandatory to enter the Bios menu to force the boot on the Ethernet using the following process: ♦ From CPU5 or CPU6 bios boot menu, select 5 - Booting from Ethernet Network or from CPU7 BIOS Loader Menu, select 03 - Load From Ethernet (4400 method) ; see Note 2. ♦ Select Standard Installation. ♦ Enter the complete version (+ patch if necessary) and the country. ♦ Enter the Linux version preceded by % (Linux version can be read under dhs3mgrversionpcmaoboot_resbootplinux) Boot Boot Menu : 1 - Booting From Floppy #0 2 - Booting From Floppy #1 3 - Booting From Hard Disk #0 4 - Booting From Hard Disk #1 5 - Booting From Ethernet Network 6 - Default Boot Sequence > 5 Booting From Ethernet Network Updating bootinfo ACT4400 specific INSTALLATION data input: ========================================= Standard installation (y/n, default is y) ? : y TEL version ? : f16023c.ca Phase 1: address determination and bootfile selection ===================================================== NB: All parameters below are optional. Default internet Address : *** Unknown *** New Internet Address : Name of default BOOTP/TFTP server : *** Unknown *** Name of a new BOOTP/TFTP server : Default loaded file : New loaded file : %15.0 BOOTP request in progress ..................... Note 1 In addition of TFTP and FTP servers, a DHCP server is activated during a standard installation and stops only when the window Installation Parameters is closed. Closing the application OmniPCX Enterprise PC Installer stops the three servers TFTP, FTP and DHCP.
  • 15. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 15 TC1319 Note 2: Case for CPU7 The standard installation of a complete version on a CPU7 Call Server can be done indifferently with the CPU 4400 or CPU Alize methods. This choice is done in the BIOS Loader Menu accessible with the commands Ctrl B and Ctrl i. The menu offers two methods of loading from Ethernet, the Alize method or the CPU 4400 method. BIOS Loader Menu 01 - Load From Hdisk #0 02 - Load From Ethernet (Alize method) 03 - Load From Ethernet (4400 method) 04 - Load From Hdisk #0 and Bootp 05 - MAC Address 06 - PCMS id 07 - System informations 08 - Set interface KENDIN to default(auto-nego) 09 - Interface KENDIN state 10 - Set Interface KENDIN 11 - Ethernet embedded interface state 12 - Full Option Menu 13 - Reset System CPU7 > The configuration of the Installation parameters of the OmniPCX Enterprise PC Installer application should be adapted to the loading method chosen. Option: 02 - Load From Ethernet (Alize method) Preliminary you have to select the Call Server type: Alize, the Call handling version and the country in the Installation parameters window of the OmniPCX Enterprise PC Installer. Option: 03 - Load from Ethernet (4400 method) Preliminary you have to select the Call Server type: A4400 in the Installation parameters window of the OmniPCX Enterprise PC Installer. The other fields are not accessible because they are selected through BIOS such as a CPU5 or CPU6 loading. Note 3: Bios access for CS-2 For CS boards, the Bios can be accessed at startup using the commands Ctrl+B and Ctrl+i. For the CS-2 boards, the Bios MUST only be accessed at startup using the single command Ctrl+B. It is strickly forbidden to add the command Ctrl+i. For more details consult technical communication TC1212 CS-2 board introduction.
  • 16. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 16 Ed. 01 / 05 March 2010 5.5. Installing the GD/GA/rGD/GD3/INTIP3 binary Installation of a GD/GA/rGD/GD3/INTIP3 binary is only done with the OmniPCX Enterprise PC Installer and a GD/GA/rGD/GD3/INTIP3 which operates a network boot on the PC server. − Open the application OmniPCX Enterprise PC Installer as described in section § 5.2 . − In the menu Preferences, select the drive that contains the PABX version to be installed. − The version must have the directories: • /dhs3mgr/"version"/pcmao/boot_res/DHS3bin/downbin/emg which contains the GD/GA/rGD binaries. • /dhs3mgr/"version"/pcmao/boot_res/DHS3bin/downbin/mg3 which contains the GD3 binaries. • /dhs3mgr/"version"/pcmao/boot_res/DHS3bin/downbin/intip3 which contains the INTIP3 binaries. − In the field Installation type, select the type of installation GD/GA/rGD/GD3/INTIP3 binary
  • 17. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 17 TC1319 − The Installation Parameters window is displayed: − In Media Gateway board designation, select the board type (GD/GA or rGD). − In Media Gateway binary versions, select the version. − In Network type, select the type of installation to Direct cable. − In Network Interface, select the network board interface used. − In IP Address, the IP address allocated to the GD/GA is displayed. − In Ethernet Address don’t set the Ethernet address (_not needed_) of the GD/GA. − Click on Apply and the following window is displayed with the greyed button Apply.
  • 18. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 18 Ed. 01 / 05 March 2010 Note In addition of TFTP server, a DHCP server is activated during installation of a GD/GA/rGD/GD3/INTIP3 binaries and stops only when the Installation Parameters window is closed. Closing the application OmniPCX Enterprise PC Installer stops the two servers TFTP and DHCP. The complete process for reformatting and reloading Flash NAND memory of GD/GA/rGD/GD3/INTIP3 is explained in technical communication TC0521 Reformatting and reloading the e-MGD Nand Flash with PC Installer.
  • 19. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 19 TC1319 6. UNINSTALLING THE PC INSTALLER To uninstall the software on the PC, follow the procedure below. − Close all the applications that are used. − In the taskbar, click on Start/Programs/OmniPCX Enterprise PC Installer/ Uninstall OmniPCX Enterprise PC Installer. The following window is displayed: − Confirm the deletion: click on Yes.
  • 20. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 20 Ed. 01 / 05 March 2010 The following window is displayed: − At the end of the uninstallation, a message indicates that the uninstallation is completed, but some elements could not be removed: A program will delete automatically these elements by clicking on OK.
  • 21. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE Ed. 01 / 05 March 2010 21 TC1319 7. EXTENDED FEATURES − From version 2.23, PC Installer supports a new country K2, used for the BiCS installation. − From version 2.24, PC Installer supports a new client: CS-2. − From version 2.26, PC Installer supports a new client: GD3, INTIP3. 8. CORRECTIONS crms00197834 PC Installer 2.26: NGP PC Installer - INTIP3 Picklist NOK. Abstract: Do the desired modifications for the INTIP3 pick list to display the required version number. crms00182355 PC Installer 2.25 : NGP PC Installer. Abstract: Make Enhance PC installer to support with GD3, INTIP3A, INTIP3B, GA3 boards. crms00043284 PC Installer 2.25: Linux 55.0: Installation Complete Not OK. Abstract: Remove: Linux+call handling"/"Reload Linux" menu in PC Installer. crms00159859 PC Installer 2.24: Add CS-2 to the pick list. Abstract: Addition of CS-2 to the dropdown list and generation of of the dhcpd.conf file for the requested configuration. 9. KNOWN RESTRICTIONS No known restriction.
  • 22. OmniPCX Enterprise INSTALLING AND USING THE OmniPCX Enterprise PC INSTALLER V2.26 SOFTWARE TC1319 22 Ed. 01 / 05 March 2010