OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 1/10
OMICRON PTL
XRIO Converter
Siemens 7SA513 V3.3
User Manual
V1.000
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 2/10
Contents
1 General Information..................................................................................................................................3
2 Quick Start Information ............................................................................................................................3
3 Using the Converter..................................................................................................................................4
4 Required Software Version ......................................................................................................................4
5 Functional Range......................................................................................................................................4
6 Not Supported Functions.........................................................................................................................5
7 OMICRON Test Strategy...........................................................................................................................5
8 Converter Structure ..................................................................................................................................5
8.1 7SA513 Section....................................................................................................................................5
8.1.1 Relay Parameter Section Block......................................................................................................5
8.1.1.1 Additional Information .............................................................................................................6
8.1.1.2 Helper Parameters/Template Controller (Advanced view) .....................................................6
8.1.2 RIOPlus (Advanced view)...............................................................................................................7
8.1.2.1 NamePlate...............................................................................................................................7
8.1.2.2 PowerSystemParameters .......................................................................................................7
8.1.2.3 Distance Protection .................................................................................................................7
8.1.2.4 Overcurrent Protection Phase-Phase .....................................................................................7
8.1.2.5 Overcurrent Protection Phase-Ground ...................................................................................7
8.1.2.6 SwitchOnToFault Function......................................................................................................8
8.1.2.7 Circuit Breaker.........................................................................................................................8
8.2 RIO .......................................................................................................................................................8
8.2.1 Distance..........................................................................................................................................8
8.2.2 DMT/IDMT Overcurrent..................................................................................................................8
8.2.3 V/I-Phi Starting L-N.........................................................................................................................9
8.2.4 V/I-Phi Starting L-L .........................................................................................................................9
8.3 Activating the RIO Functions................................................................................................................9
8.4 Specific Features................................................................................................................................10
8.4.1 Distance Protection Controlled Zone Z1L ....................................................................................10
8.5 Handling the Infinity Value..................................................................................................................10
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 3/10
1 General Information
The Siemens 7SA513 XRIO converter is designed for testing Siemens 7SA513 distance protection relays
by using the OMICRON Test Universe 2.11 software. The converter provides all necessary data for
testing the distance protection functions (see section 2 ) of the 7SA513 relays. The converter is tested
with the following relay:
• 7SA513 V3.2
• MLFB: 7SA51315CA230CH1
Note: This converter is tested with the relay described above. It will work with 7SA513 relay series. It may
work with similar relays, too.
2 Quick Start Information
To work with the Siemens 7SA513 XRIO converter:
1. Start a new OMICRON Control Center (OCC) document or open an existing OCC document.
2. Insert a new test object or open the existing test object.
3. On the File menu, click Import.
4. Browse to the 7SA513.xrio file.
5. Click Open.
6. Enter all necessary settings in the Customer Input section (see section 8.1 ).
7. Insert +inf (infinity) to disable settings/functions, if necessary.
8. Click OK.
9.
Figure 1: Opening and importing the Siemens 7SA513 XRIO converter
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 4/10
3 Using the Converter
The Siemens 7SA513 XRIO converter can be used as a stand-alone converter or in association with a
relay specific test template, for example with the OMICRON Distance template for the 7SA513 relay.
In any way the converter is used, follow the quick start instructions and create your test by using
LinkToXRIO or start using the relay specific test template (for more information, see the test template
documentation).
See sections 8.1 - 8.4 for more information about using the XRIO converter with the OMICRON
Distance test module.
4 Required Software Version
To use this converter, you must have a valid license for the OMICRON Test Universe 2.11 SR1 software.
5 Functional Range
The Siemens 7SA513 XRIO converter implements the following functions:
• 21 Distance (quadrilateral)
• 50, 50N, 51, 51N BUOC
• 79 Autoreclosure
Figure 2: Functional range of the Siemens 7SA513 XRIO converter
For some of the functions listed above use the RIO interface of the Test Universe software. Consequently,
the test modules are configured automatically without using LinkToXRIO.
The following functions are using the RIO interface:
• 21 Distance (quadrilateral)
• 21 Distance starting (Overcurrent ''Always ON '' , Impedance , and V/I/Phi Starting)
• 50/51 BUOC
For testing the other functions, you must use LinkToXRIO.
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 5/10
6 Not Supported Functions
The following functions are currently not supported:
• 68 Power Swing Detection
• Teleprotection Interface (PUTT/POTT)
• Weak infeed protection
• Ground Fault Detection in Non-Grounded Systems
• High-Resistance Ground Fault Protection in Solidly Ground Systems
• 79 Auto-reclosure function
• 25 Synchronism and Voltage Check
• Overcurrent protection (DTL/IDMTL)
• Overvoltage protection
• 50 Breaker failure protection.
7 OMICRON Test Strategy
The OMICRON test strategy is described in the OMICRON Protection Test Template (PTT) Distance
documentation. For detailed information, see the PTT Distance documentation.
8 Converter Structure
The converter is divided into two sections: the 7SA513 section and the RIO section. Both sections consist
of several function blocks. The converter comes up in the standard view; the RIOplus section and the
template controller section can only be seen in the advanced view.
8.1 7SA513 Section
The Customer Input section includes parameters which can be changed by the user. All relay
parameters are included in this section and can be set to the actual relay values.
8.1.1 Relay Parameter Section Block
In this block, setting parameters are included. The parameters are grouped and named as in the Siemens
DIGSI software. Each parameter in this block can be identified by a Foreign ID, which is identical to the
parameter ID in DIGSI.
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 6/10
Figure 3: Setting the parameters in the Customer Input section
8.1.1.1 Additional Information
This block has been added for relay specific parameters such as tolerances or angles of directional
elements which cannot be set by the user, because they are constant values. All values set in this block
can be found in the chapter "Technical Data" of the relay's documentation. Typically, these blocks do not
have to be changed (except the General Information and Circuit Breaker Information block), as they are
already set to the values given in the user manual of the relay.
Figure 4: Setting general information
The General Information block contains the parameters which are important for the test report, e.g.
information about the substation and the feeder. Furthermore it contains power system parameters which
are important for the test modules. These parameters are linked to the device part of the RIO section and
are available in the test report.
8.1.1.2 Helper Parameters/Template Controller (Advanced view)
The Helper Parameters block contains special values which are needed for some tests, especially for
tests using LinkToXRIO. These are mainly calculated values which cannot be calculated by using
LinkToXRIO and therefore have to be stored in this section. Other values needed for customer designed
tests can be stored in this block.
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 7/10
8.1.2 RIOPlus (Advanced view)
The RIOplus block contains the interface, which provides the link between the XRIO converter and all test
modules which have no access to RIO functions. All tests using basic test modules like Ramping or State
Sequencer have to be linked to the parameters in the RIOplus section of the converter.
8.1.2.1 NamePlate
The NamePlate block contains all necessary information to identify the protection device to be tested. This
block contains the relay vendor, serial number, model, the relay location and a description.
8.1.2.2 PowerSystemParameters
The number of phases, phase rotation and the nominal frequency are stored in this block.
8.1.2.3 Distance Protection
This block contains all necessary data to test the distance protection quadrilateral zones. The nominal
values and the CT / VT settings used by the distance protection functions can be found here. All zones of
the distance quadrilateral protection function in the relay are modeled as subblocks of the
ImpedanceZoneElements blocks. Each zone subblock stores information about:
• the grounding factors in the GroundingFactor subblock
• the impedances in the BorderElements and GenericShape subblocks
• the reach and Phi values and tolerances in the Reach subblock
• the operating and reset delay time values and tolerances in the OperateDelayTime and
ResetDelayTime subblocks
All necessary data for testing the overcurrent, impedance, and V/I-Phi starting signals are stored in the
StartingElements subblock.
8.1.2.4 Overcurrent Protection Phase-Phase
This block contains all necessary data to test the phase-phase emergency overcurrent protection. The
nominal values and the CT/VT settings used by this protection function can be found here. All stages of
the phase-phase emergency overcurrent protection function in the relay are modeled as subblocks of the
overcurrent protection phase-phase block. Each stage subblock stores information about the directional
element, pickup value, operating time, pickup-drop off ratio and the curve type of the modeled overcurrent
stage.
8.1.2.5 Overcurrent Protection Phase-Ground
This block contains all necessary data to test the phase-ground emergency overcurrent protection. The
nominal values and the CT/VT settings used by this protection function can be found here. All stages of
the phase-ground emergency overcurrent protection function in the relay are modeled as subblocks of the
OverCurrentProtection Phase – Ground block. Each stage subblock stores information about the
directional element, pickup value, operating time, pickup-drop off ratio and the curve type of the modeled
overcurrent stage.
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 8/10
8.1.2.6 SwitchOnToFault Function
This block contains all necessary data to test the switch on to fault protection. The nominal values and the
CT/VT settings used by this protection function can be found here. The main data parameters of the
switch on to fault are:
• MinOperateTime
• MaxOperateTime
• OperateDelayTime
• ResetDelayTime
• CurrentDetectorValue
These main data parameters are stored in the SwitchOnToFaultElement1 of the
SwitchOnToFaultElements block. The voltage and current values of the pre-fault and post-fault states are
stored in the TestCondition block.
8.1.2.7 Circuit Breaker
The circuit breaker block contains all necessary data for testing protection functions together with the
circuit breaker. The modeled parameters are 52abPercentage, CloseTime, Forced3PoleOperatingTime,
SinglePoleTripping, TripTime, TripCommandDuration and ClosedBreakerMinCurrentThreshold.
8.2 RIO
The RIO section of the converter contains all specialized RIO functions which are needed to use the more
specialized test modules (like Advanced Distance or Overcurrent) provided by the OMICRON Test
Universe software.
Warning: Do not change any values in this section. The values have been set using the relay settings of
the Customer Input section.
Note: Do not activate the former test object view in the advanced mode of the XRIO test object. Changing
parameters in this view will disable formulas in the RIO section.
8.2.1 Distance
This RIO distance function provides the necessary values for testing the distance protection functions of
the 7SA513 relay with the Advanced Distance test module. The protection functions supported by this RIO
function include:
• 21 Distance quadrilateral
The following RIO function for testing these distance protection functions is available:
• Distance
8.2.2 DMT/IDMT Overcurrent
This RIO overcurrent function provides the necessary values for testing the emergency overcurrent
protection functions of the 7SA513 relay with the Overcurrent test module. The protection functions
supported by this RIO function include:
• DMT / IDMT Phase/Ground overcurrent
The following RIO function for testing these overcurrent protection functions is available:
• Overcurrent
The three stages with the smallest pickup values are combined and the resulting characteristic curve is
shown in the RIO overcurrent function block.
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 9/10
8.2.3 V/I-Phi Starting L-N
This RIO distance starting function provides the necessary values for testing the distance starting
functions of the 7SA6x relay with the VI Starting test module. The starting functions supported by this RIO
function include:
• 21 Distance Starting V/I-Phi LN
The following RIO function for testing these distance protection functions is available:
• V/I Starting
8.2.4 V/I-Phi Starting L-L
This RIO distance starting function provides the necessary values for testing the distance starting
functions of the 7SA6x relay with the VI Starting test module. The starting functions supported by this RIO
function include:
• 21 Distance Starting V/I-Phi LL
The following RIO function for testing these distance protection functions is available:
• V/I Starting
8.3 Activating the RIO Functions
The RIO functions have to be set to active manually in each VIPhi Starting test module if the converter is
used in the stand-alone mode. Activate the RIO function you intend to use in the local hardware
configuration as shown in figure 5.
Figure 5: Activating a RIO function
OMICRON PTL Siemens 7SA513 XRIO Converter User Manual
© OMICRON electronics GmbH 10/10
8.4 Specific Features
This section deals with special requirements of some of the converter's functions. Functions not listed
here have no known limitations to their functionalities.
8.4.1 Distance Protection Controlled Zone Z1L
The overreach zone Z1L, activated by multi-shot AR (2
nd
and further cycles, so-called DAR) or controlled
via binary input, is mapped in RioPlus and Rio and can be tested. At the moment no test procedure for
testing the Z1L zone is implemented in the PTT (Protection Test Template). To test the trip time and the
reach of zone Z1L implement for each test condition an Advanced Distance module in the PTT, e.g. see
the test procedure Testing Z1B.
8.5 Handling the Infinity Value
The infinity value has to be set to +inf in the 7SA513 section of the converter. It is used in the same way
as the "+*" in the DIGSI software. Consequently, the protection functions which are disabled by setting
them to infinity in DIGSI, behave the same way in the converter.

Mais conteúdo relacionado

Mais procurados

Lecture 14 ME 176 7 Root Locus Technique
Lecture 14 ME 176 7 Root Locus TechniqueLecture 14 ME 176 7 Root Locus Technique
Lecture 14 ME 176 7 Root Locus Technique
Leonides De Ocampo
 
Power Plant Training Certificates
Power Plant Training CertificatesPower Plant Training Certificates
Power Plant Training Certificates
atavane
 
Chapter 6 power electronic-devices
Chapter 6 power electronic-devicesChapter 6 power electronic-devices
Chapter 6 power electronic-devices
mkazree
 

Mais procurados (20)

Programmable Logic Controller
Programmable Logic ControllerProgrammable Logic Controller
Programmable Logic Controller
 
Ipsa mv relay co-ordiantion shaik adam
Ipsa  mv relay  co-ordiantion shaik adamIpsa  mv relay  co-ordiantion shaik adam
Ipsa mv relay co-ordiantion shaik adam
 
POLLUTION TEST OF NATURALLY AND ARTIFICIALLY CONTAMINATED INSULATORS
POLLUTION TEST OF NATURALLY AND ARTIFICIALLY CONTAMINATED INSULATORSPOLLUTION TEST OF NATURALLY AND ARTIFICIALLY CONTAMINATED INSULATORS
POLLUTION TEST OF NATURALLY AND ARTIFICIALLY CONTAMINATED INSULATORS
 
Relay testing procedure
Relay testing procedure Relay testing procedure
Relay testing procedure
 
47526172-DIFFERENTIAL-PROTECTION-8.pptx
47526172-DIFFERENTIAL-PROTECTION-8.pptx47526172-DIFFERENTIAL-PROTECTION-8.pptx
47526172-DIFFERENTIAL-PROTECTION-8.pptx
 
Relay Setting Calculation For REF615/ REJ601
Relay Setting Calculation For REF615/ REJ601Relay Setting Calculation For REF615/ REJ601
Relay Setting Calculation For REF615/ REJ601
 
Power Quality
Power QualityPower Quality
Power Quality
 
CAM ladder logic diagram
CAM ladder logic diagramCAM ladder logic diagram
CAM ladder logic diagram
 
02 physical.system.modelling mechanical.systems.
02 physical.system.modelling mechanical.systems.02 physical.system.modelling mechanical.systems.
02 physical.system.modelling mechanical.systems.
 
REPORT ON INDUSTRIAL AUTOMATION
REPORT ON INDUSTRIAL AUTOMATIONREPORT ON INDUSTRIAL AUTOMATION
REPORT ON INDUSTRIAL AUTOMATION
 
Training Report on Automation
Training Report on AutomationTraining Report on Automation
Training Report on Automation
 
vcla
vclavcla
vcla
 
Lecture 14 ME 176 7 Root Locus Technique
Lecture 14 ME 176 7 Root Locus TechniqueLecture 14 ME 176 7 Root Locus Technique
Lecture 14 ME 176 7 Root Locus Technique
 
Power Plant Training Certificates
Power Plant Training CertificatesPower Plant Training Certificates
Power Plant Training Certificates
 
Chapter 6 power electronic-devices
Chapter 6 power electronic-devicesChapter 6 power electronic-devices
Chapter 6 power electronic-devices
 
7SA522 Distance Protection Relay For Transmission Lines
7SA522 Distance Protection Relay For Transmission Lines7SA522 Distance Protection Relay For Transmission Lines
7SA522 Distance Protection Relay For Transmission Lines
 
INTRODUCTIONTOPOWERELECTRONICS.pdf
INTRODUCTIONTOPOWERELECTRONICS.pdfINTRODUCTIONTOPOWERELECTRONICS.pdf
INTRODUCTIONTOPOWERELECTRONICS.pdf
 
Analogous system 4
Analogous system 4Analogous system 4
Analogous system 4
 
AUTO-RECLOSING & LOCAL SYSTEM RESTORATION
AUTO-RECLOSING & LOCAL SYSTEM RESTORATIONAUTO-RECLOSING & LOCAL SYSTEM RESTORATION
AUTO-RECLOSING & LOCAL SYSTEM RESTORATION
 
INTERNSHIP REPORT done by Didier Iradukunda (Electrical and Computer Engineer...
INTERNSHIP REPORT done by Didier Iradukunda (Electrical and Computer Engineer...INTERNSHIP REPORT done by Didier Iradukunda (Electrical and Computer Engineer...
INTERNSHIP REPORT done by Didier Iradukunda (Electrical and Computer Engineer...
 

Semelhante a Xrio converter manual 7 sa513 v3.3 enu tu2.11 v1.000

Selection of PMU functionality
Selection of PMU functionalitySelection of PMU functionality
Selection of PMU functionality
Power System Operation
 
1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured
1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured
1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured
Javier Cuzco
 
Applied motion products txm24 rs232 485 brochure
Applied motion products txm24 rs232 485 brochureApplied motion products txm24 rs232 485 brochure
Applied motion products txm24 rs232 485 brochure
Electromate
 

Semelhante a Xrio converter manual 7 sa513 v3.3 enu tu2.11 v1.000 (20)

Selection of PMU functionality
Selection of PMU functionalitySelection of PMU functionality
Selection of PMU functionality
 
single-phase-acr10r-d16te-manual.pdf
single-phase-acr10r-d16te-manual.pdfsingle-phase-acr10r-d16te-manual.pdf
single-phase-acr10r-d16te-manual.pdf
 
Mc9 s08sh8
Mc9 s08sh8Mc9 s08sh8
Mc9 s08sh8
 
1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured
1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured
1 mrk511232 ben-e_en_product_guide__rec670_1.2_pre-configured
 
lm555.pdf
lm555.pdflm555.pdf
lm555.pdf
 
Danfoss vlt fc 101 programming guide
Danfoss vlt fc 101 programming guideDanfoss vlt fc 101 programming guide
Danfoss vlt fc 101 programming guide
 
Hoja de datos lm 555 y configuraciones
Hoja de datos lm 555 y configuraciones Hoja de datos lm 555 y configuraciones
Hoja de datos lm 555 y configuraciones
 
Applied motion products txm24 rs232 485 brochure
Applied motion products txm24 rs232 485 brochureApplied motion products txm24 rs232 485 brochure
Applied motion products txm24 rs232 485 brochure
 
Applied motion products txm24 c brochure
Applied motion products txm24 c brochureApplied motion products txm24 c brochure
Applied motion products txm24 c brochure
 
Rb411ug a
Rb411ug aRb411ug a
Rb411ug a
 
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_cCataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
 
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_cCataloge ge 3.control and_automation-01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_c
 
Picaxe manual3 interfaces
Picaxe manual3 interfacesPicaxe manual3 interfaces
Picaxe manual3 interfaces
 
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
CW-15K_checkweigher User’s manual ( A p p l i c a b l e f o r M C G S + C 0 1...
 
Siemens catalog tong hop 3 uf simocode
Siemens catalog tong hop 3 uf simocodeSiemens catalog tong hop 3 uf simocode
Siemens catalog tong hop 3 uf simocode
 
PLC: Manual del PLC micro3 IDEC
PLC: Manual del PLC micro3 IDECPLC: Manual del PLC micro3 IDEC
PLC: Manual del PLC micro3 IDEC
 
Rej603 pg 1_mdb07217-yn_e_ne
Rej603 pg 1_mdb07217-yn_e_neRej603 pg 1_mdb07217-yn_e_ne
Rej603 pg 1_mdb07217-yn_e_ne
 
Hướng dẫn vận hành Danfoss VLT FC 300
Hướng dẫn vận hành Danfoss VLT FC 300Hướng dẫn vận hành Danfoss VLT FC 300
Hướng dẫn vận hành Danfoss VLT FC 300
 
Vlt fc 300 operating instructions
Vlt fc 300 operating instructionsVlt fc 300 operating instructions
Vlt fc 300 operating instructions
 
Ap 300 access port internal antenna model
Ap 300 access port   internal antenna modelAp 300 access port   internal antenna model
Ap 300 access port internal antenna model
 

Último

Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
jaanualu31
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
Kamal Acharya
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
MayuraD1
 

Último (20)

Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
 
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best ServiceTamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
 
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to ComputersComputer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptxA CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 

Xrio converter manual 7 sa513 v3.3 enu tu2.11 v1.000

  • 1. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 1/10 OMICRON PTL XRIO Converter Siemens 7SA513 V3.3 User Manual V1.000
  • 2. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 2/10 Contents 1 General Information..................................................................................................................................3 2 Quick Start Information ............................................................................................................................3 3 Using the Converter..................................................................................................................................4 4 Required Software Version ......................................................................................................................4 5 Functional Range......................................................................................................................................4 6 Not Supported Functions.........................................................................................................................5 7 OMICRON Test Strategy...........................................................................................................................5 8 Converter Structure ..................................................................................................................................5 8.1 7SA513 Section....................................................................................................................................5 8.1.1 Relay Parameter Section Block......................................................................................................5 8.1.1.1 Additional Information .............................................................................................................6 8.1.1.2 Helper Parameters/Template Controller (Advanced view) .....................................................6 8.1.2 RIOPlus (Advanced view)...............................................................................................................7 8.1.2.1 NamePlate...............................................................................................................................7 8.1.2.2 PowerSystemParameters .......................................................................................................7 8.1.2.3 Distance Protection .................................................................................................................7 8.1.2.4 Overcurrent Protection Phase-Phase .....................................................................................7 8.1.2.5 Overcurrent Protection Phase-Ground ...................................................................................7 8.1.2.6 SwitchOnToFault Function......................................................................................................8 8.1.2.7 Circuit Breaker.........................................................................................................................8 8.2 RIO .......................................................................................................................................................8 8.2.1 Distance..........................................................................................................................................8 8.2.2 DMT/IDMT Overcurrent..................................................................................................................8 8.2.3 V/I-Phi Starting L-N.........................................................................................................................9 8.2.4 V/I-Phi Starting L-L .........................................................................................................................9 8.3 Activating the RIO Functions................................................................................................................9 8.4 Specific Features................................................................................................................................10 8.4.1 Distance Protection Controlled Zone Z1L ....................................................................................10 8.5 Handling the Infinity Value..................................................................................................................10
  • 3. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 3/10 1 General Information The Siemens 7SA513 XRIO converter is designed for testing Siemens 7SA513 distance protection relays by using the OMICRON Test Universe 2.11 software. The converter provides all necessary data for testing the distance protection functions (see section 2 ) of the 7SA513 relays. The converter is tested with the following relay: • 7SA513 V3.2 • MLFB: 7SA51315CA230CH1 Note: This converter is tested with the relay described above. It will work with 7SA513 relay series. It may work with similar relays, too. 2 Quick Start Information To work with the Siemens 7SA513 XRIO converter: 1. Start a new OMICRON Control Center (OCC) document or open an existing OCC document. 2. Insert a new test object or open the existing test object. 3. On the File menu, click Import. 4. Browse to the 7SA513.xrio file. 5. Click Open. 6. Enter all necessary settings in the Customer Input section (see section 8.1 ). 7. Insert +inf (infinity) to disable settings/functions, if necessary. 8. Click OK. 9. Figure 1: Opening and importing the Siemens 7SA513 XRIO converter
  • 4. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 4/10 3 Using the Converter The Siemens 7SA513 XRIO converter can be used as a stand-alone converter or in association with a relay specific test template, for example with the OMICRON Distance template for the 7SA513 relay. In any way the converter is used, follow the quick start instructions and create your test by using LinkToXRIO or start using the relay specific test template (for more information, see the test template documentation). See sections 8.1 - 8.4 for more information about using the XRIO converter with the OMICRON Distance test module. 4 Required Software Version To use this converter, you must have a valid license for the OMICRON Test Universe 2.11 SR1 software. 5 Functional Range The Siemens 7SA513 XRIO converter implements the following functions: • 21 Distance (quadrilateral) • 50, 50N, 51, 51N BUOC • 79 Autoreclosure Figure 2: Functional range of the Siemens 7SA513 XRIO converter For some of the functions listed above use the RIO interface of the Test Universe software. Consequently, the test modules are configured automatically without using LinkToXRIO. The following functions are using the RIO interface: • 21 Distance (quadrilateral) • 21 Distance starting (Overcurrent ''Always ON '' , Impedance , and V/I/Phi Starting) • 50/51 BUOC For testing the other functions, you must use LinkToXRIO.
  • 5. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 5/10 6 Not Supported Functions The following functions are currently not supported: • 68 Power Swing Detection • Teleprotection Interface (PUTT/POTT) • Weak infeed protection • Ground Fault Detection in Non-Grounded Systems • High-Resistance Ground Fault Protection in Solidly Ground Systems • 79 Auto-reclosure function • 25 Synchronism and Voltage Check • Overcurrent protection (DTL/IDMTL) • Overvoltage protection • 50 Breaker failure protection. 7 OMICRON Test Strategy The OMICRON test strategy is described in the OMICRON Protection Test Template (PTT) Distance documentation. For detailed information, see the PTT Distance documentation. 8 Converter Structure The converter is divided into two sections: the 7SA513 section and the RIO section. Both sections consist of several function blocks. The converter comes up in the standard view; the RIOplus section and the template controller section can only be seen in the advanced view. 8.1 7SA513 Section The Customer Input section includes parameters which can be changed by the user. All relay parameters are included in this section and can be set to the actual relay values. 8.1.1 Relay Parameter Section Block In this block, setting parameters are included. The parameters are grouped and named as in the Siemens DIGSI software. Each parameter in this block can be identified by a Foreign ID, which is identical to the parameter ID in DIGSI.
  • 6. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 6/10 Figure 3: Setting the parameters in the Customer Input section 8.1.1.1 Additional Information This block has been added for relay specific parameters such as tolerances or angles of directional elements which cannot be set by the user, because they are constant values. All values set in this block can be found in the chapter "Technical Data" of the relay's documentation. Typically, these blocks do not have to be changed (except the General Information and Circuit Breaker Information block), as they are already set to the values given in the user manual of the relay. Figure 4: Setting general information The General Information block contains the parameters which are important for the test report, e.g. information about the substation and the feeder. Furthermore it contains power system parameters which are important for the test modules. These parameters are linked to the device part of the RIO section and are available in the test report. 8.1.1.2 Helper Parameters/Template Controller (Advanced view) The Helper Parameters block contains special values which are needed for some tests, especially for tests using LinkToXRIO. These are mainly calculated values which cannot be calculated by using LinkToXRIO and therefore have to be stored in this section. Other values needed for customer designed tests can be stored in this block.
  • 7. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 7/10 8.1.2 RIOPlus (Advanced view) The RIOplus block contains the interface, which provides the link between the XRIO converter and all test modules which have no access to RIO functions. All tests using basic test modules like Ramping or State Sequencer have to be linked to the parameters in the RIOplus section of the converter. 8.1.2.1 NamePlate The NamePlate block contains all necessary information to identify the protection device to be tested. This block contains the relay vendor, serial number, model, the relay location and a description. 8.1.2.2 PowerSystemParameters The number of phases, phase rotation and the nominal frequency are stored in this block. 8.1.2.3 Distance Protection This block contains all necessary data to test the distance protection quadrilateral zones. The nominal values and the CT / VT settings used by the distance protection functions can be found here. All zones of the distance quadrilateral protection function in the relay are modeled as subblocks of the ImpedanceZoneElements blocks. Each zone subblock stores information about: • the grounding factors in the GroundingFactor subblock • the impedances in the BorderElements and GenericShape subblocks • the reach and Phi values and tolerances in the Reach subblock • the operating and reset delay time values and tolerances in the OperateDelayTime and ResetDelayTime subblocks All necessary data for testing the overcurrent, impedance, and V/I-Phi starting signals are stored in the StartingElements subblock. 8.1.2.4 Overcurrent Protection Phase-Phase This block contains all necessary data to test the phase-phase emergency overcurrent protection. The nominal values and the CT/VT settings used by this protection function can be found here. All stages of the phase-phase emergency overcurrent protection function in the relay are modeled as subblocks of the overcurrent protection phase-phase block. Each stage subblock stores information about the directional element, pickup value, operating time, pickup-drop off ratio and the curve type of the modeled overcurrent stage. 8.1.2.5 Overcurrent Protection Phase-Ground This block contains all necessary data to test the phase-ground emergency overcurrent protection. The nominal values and the CT/VT settings used by this protection function can be found here. All stages of the phase-ground emergency overcurrent protection function in the relay are modeled as subblocks of the OverCurrentProtection Phase – Ground block. Each stage subblock stores information about the directional element, pickup value, operating time, pickup-drop off ratio and the curve type of the modeled overcurrent stage.
  • 8. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 8/10 8.1.2.6 SwitchOnToFault Function This block contains all necessary data to test the switch on to fault protection. The nominal values and the CT/VT settings used by this protection function can be found here. The main data parameters of the switch on to fault are: • MinOperateTime • MaxOperateTime • OperateDelayTime • ResetDelayTime • CurrentDetectorValue These main data parameters are stored in the SwitchOnToFaultElement1 of the SwitchOnToFaultElements block. The voltage and current values of the pre-fault and post-fault states are stored in the TestCondition block. 8.1.2.7 Circuit Breaker The circuit breaker block contains all necessary data for testing protection functions together with the circuit breaker. The modeled parameters are 52abPercentage, CloseTime, Forced3PoleOperatingTime, SinglePoleTripping, TripTime, TripCommandDuration and ClosedBreakerMinCurrentThreshold. 8.2 RIO The RIO section of the converter contains all specialized RIO functions which are needed to use the more specialized test modules (like Advanced Distance or Overcurrent) provided by the OMICRON Test Universe software. Warning: Do not change any values in this section. The values have been set using the relay settings of the Customer Input section. Note: Do not activate the former test object view in the advanced mode of the XRIO test object. Changing parameters in this view will disable formulas in the RIO section. 8.2.1 Distance This RIO distance function provides the necessary values for testing the distance protection functions of the 7SA513 relay with the Advanced Distance test module. The protection functions supported by this RIO function include: • 21 Distance quadrilateral The following RIO function for testing these distance protection functions is available: • Distance 8.2.2 DMT/IDMT Overcurrent This RIO overcurrent function provides the necessary values for testing the emergency overcurrent protection functions of the 7SA513 relay with the Overcurrent test module. The protection functions supported by this RIO function include: • DMT / IDMT Phase/Ground overcurrent The following RIO function for testing these overcurrent protection functions is available: • Overcurrent The three stages with the smallest pickup values are combined and the resulting characteristic curve is shown in the RIO overcurrent function block.
  • 9. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 9/10 8.2.3 V/I-Phi Starting L-N This RIO distance starting function provides the necessary values for testing the distance starting functions of the 7SA6x relay with the VI Starting test module. The starting functions supported by this RIO function include: • 21 Distance Starting V/I-Phi LN The following RIO function for testing these distance protection functions is available: • V/I Starting 8.2.4 V/I-Phi Starting L-L This RIO distance starting function provides the necessary values for testing the distance starting functions of the 7SA6x relay with the VI Starting test module. The starting functions supported by this RIO function include: • 21 Distance Starting V/I-Phi LL The following RIO function for testing these distance protection functions is available: • V/I Starting 8.3 Activating the RIO Functions The RIO functions have to be set to active manually in each VIPhi Starting test module if the converter is used in the stand-alone mode. Activate the RIO function you intend to use in the local hardware configuration as shown in figure 5. Figure 5: Activating a RIO function
  • 10. OMICRON PTL Siemens 7SA513 XRIO Converter User Manual © OMICRON electronics GmbH 10/10 8.4 Specific Features This section deals with special requirements of some of the converter's functions. Functions not listed here have no known limitations to their functionalities. 8.4.1 Distance Protection Controlled Zone Z1L The overreach zone Z1L, activated by multi-shot AR (2 nd and further cycles, so-called DAR) or controlled via binary input, is mapped in RioPlus and Rio and can be tested. At the moment no test procedure for testing the Z1L zone is implemented in the PTT (Protection Test Template). To test the trip time and the reach of zone Z1L implement for each test condition an Advanced Distance module in the PTT, e.g. see the test procedure Testing Z1B. 8.5 Handling the Infinity Value The infinity value has to be set to +inf in the 7SA513 section of the converter. It is used in the same way as the "+*" in the DIGSI software. Consequently, the protection functions which are disabled by setting them to infinity in DIGSI, behave the same way in the converter.