SlideShare uma empresa Scribd logo
1 de 124
CIRCUIT TESTERS AND DIGITAL METERS 42
Objectives ,[object Object],[object Object],[object Object],[object Object]
Objectives ,[object Object],[object Object],[object Object],[object Object]
FUSED JUMPER WIRE
Fused Jumper Wire ,[object Object],[object Object],[object Object]
Fused Jumper Wire ,[object Object],[object Object],[object Object],[object Object]
Figure 42-1   A technician-made fused jumper lead, which is equipped with a red 10 ampere fuse. This fused jumper wire uses terminals for testing circuits at a connector instead of alligator clips.
Fused Jumper Wire ,[object Object],[object Object],[object Object]
TEST LIGHTS
Test Lights ,[object Object],[object Object],[object Object]
Figure 42-2   A 12 volt test light is attached to a good ground while probing for power.
Figure 42-3   A test light can be used to locate an open in a circuit. Note that the test light is grounded at a different location than the circuit itself.
Test Lights ,[object Object],[object Object],[object Object]
Test Lights ,[object Object],[object Object],[object Object]
Test Lights ,[object Object],[object Object]
Figure 42-4   A continuity light should not be used on computer circuits because the applied voltage can damage delicate electronic components or circuits.
Test Lights ,[object Object],[object Object],[object Object]
Test Lights ,[object Object],[object Object],[object Object],[object Object]
Test Lights ,[object Object],[object Object],[object Object],[object Object]
Figure 42-5   An LED test light can be easily made using low cost components and an old ink pen. With the 470 ohm resistor in series with the LED, this tester only draws 0.025 ampere (25 milliamperes) from the circuit being tested. This low current draw helps assure the technician that the circuit or component being tested will not be damaged by excessive current flow.
LOGIC PROBE
Logic Probe ,[object Object],[object Object],[object Object]
Logic Probe ,[object Object],[object Object],[object Object]
Logic Probe ,[object Object],[object Object],[object Object]
Logic Probe ,[object Object],[object Object],[object Object]
Logic Probe ,[object Object],[object Object],[object Object]
Figure 42-6   A logic probe connected to the vehicle battery. When the tip probe is connected to a circuit, it can check for power, ground, or a pulse.
Logic Probe ,[object Object],[object Object],[object Object]
Logic Probe ,[object Object],[object Object],[object Object]
Logic Probe ,[object Object],[object Object],[object Object],[object Object],[object Object]
DIGITAL MULTIMETERS
Digital Multimeters ,[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Figure 42-7   Typical digital multimeter. The black meter lead always is placed in the COM terminal. The red meter test lead should be in the volt-ohm terminal except when measuring current in amperes.
Chart 42-1  Common symbols and abbreviations used on digital meters.
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Figure 42-8   Typical digital multimeter (DMM) set to read DC volts.
Figure 42-9 (a)   A typical autoranging digital multimeter automatically selects the proper scale to read the voltage being tested. The scale selected is usually displayed on the meter face. Note that the display indicates “4,” meaning that this range can read up to 4 volts.
Figure 42-9 (b)   A typical autoranging digital multimeter automatically selects the proper scale to read the voltage being tested. The scale selected is usually displayed on the meter face.The range is now set to the 40 volt scale, meaning that the meter can read up to 40 volts on the scale. Any reading above this level will cause the meter to reset to a higher scale. If not set on autoranging, the meter display would indicate OL if a reading exceeds the limit of the scale selected.
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object]
Digital Multimeters ,[object Object],[object Object],[object Object],?
Figure 42-10   Using a digital multimeter set to read ohms (Ω) to test this light bulb. The meter reads the resistance of the filament.
Figure 42-11   Many digital multimeters can have the display indicate zero to compensate for test lead resistance. (1) Connect leads in the V Ω and COM meter terminals. (2) Select the Ω scale. (3) Touch the two meter leads together. (4) Push the “zero” or “relative” button on the meter. (5) The meter display will now indicate zero ohms of resistance.
Digital Multimeters ,[object Object],[object Object],[object Object],?
Figure 42-12   Measuring the current flow required by a horn requires that the ammeter be connected to the circuit in series and the horn button be depressed by an assistant.
INDUCTIVE AMMETERS
Inductive Ammeters ,[object Object],[object Object],[object Object]
Inductive Ammeters ,[object Object],[object Object],[object Object]
Figure 42-14   An inductive ammeter clamp is used with all starting and charging testers to measure the current flow through the battery cables.
Inductive Ammeters ,[object Object],[object Object],[object Object]
Inductive Ammeters ,[object Object],[object Object],[object Object]
Figure 42-15   A typical mini clamp-on-type digital multimeter. This meter is capable of measuring alternating current (AC) and direct current (DC) without requiring that the circuit be disconnected to install the meter in series. The jaws are simply placed over the wire and current flow through the circuit is displayed.
DIODE CHECK,  PULSE WIDTH, AND FREQUENCY
Diode Check, Pulse Width, and Frequency ,[object Object],[object Object],[object Object],[object Object]
Diode Check, Pulse Width, and Frequency ,[object Object],[object Object],[object Object]
Diode Check, Pulse Width, and Frequency ,[object Object],[object Object],[object Object]
Diode Check, Pulse Width, and Frequency ,[object Object],[object Object],[object Object]
Diode Check Pulse Width and Frequency ,[object Object],[object Object],[object Object],[object Object],Diode Check, Pulse Width, and Frequency
Diode Check, Pulse Width, and Frequency ,[object Object],[object Object],[object Object]
Diode Check, Pulse Width, and Frequency ,[object Object],[object Object],[object Object]
ELECTRICAL UNIT PREFIXES
Electrical Unit Prefixes ,[object Object],[object Object],[object Object]
Electrical Unit Prefixes ,[object Object],[object Object],[object Object],[object Object]
Electrical Unit Prefixes ,[object Object],[object Object],[object Object]
Figure 42-17   Always look at the meter display when a measurement is being made, especially if using an autoranging meter.
Chart 42-2  A conversion chart showing the decimal point location for the various prefixes.
Electrical Unit Prefixes ,[object Object],[object Object],[object Object],[object Object]
HOW TO READ DIGITAL METERS
How to Read Digital Meters ,[object Object],[object Object],[object Object]
How to Read Digital Meters ,[object Object],[object Object],[object Object]
Chart 42-3  Sample meter readings using manually set and autoranging selection on the digital meter control.
Chart 42-3 (continued)  Sample meter readings using manually set and autoranging selection on the digital meter control.
How to Read Digital Meters ,[object Object],[object Object],[object Object]
Figure 42-18   When reading AC voltage signals, a true RMS meter (such as a Fluke 87) provides a different reading than an average responding meter (such as a Fluke 88). The only place this difference is important is when a reading is to be compared with a specification.
How to Read Digital Meters ,[object Object],[object Object],[object Object]
How to Read Digital Meters ,[object Object],[object Object],[object Object]
How to Read Digital Meters ,[object Object],[object Object],[object Object]
How to Read Digital Meters ,[object Object],[object Object]
Figure 42-19   This meter display shows 052.2 AC volts. Notice that the zero beside the 5 indicates that the meter can read over 100 volts AC with a resolution of 0.1 volt.
How to Read Digital Meters ,[object Object],[object Object],[object Object]
How to Read Digital Meters ,[object Object],[object Object]
How to Read Digital Meters ,[object Object],[object Object],[object Object],[object Object]
How to Read Digital Meters ,[object Object],[object Object],[object Object],[object Object]
DIGITAL METER USAGE 1   For most electrical measurements, the black meter lead is inserted in the terminal labeled COM and the red meter lead is inserted into the terminal labeled V.
DIGITAL METER USAGE 2   To use a digital meter, turn the power switch and select the unit of electricity to be measured. In this case, the rotary switch is turned to select DC volts. (V)
DIGITAL METER USAGE 3   For most automotive electrical use, such as measuring battery voltage, select DC volts.
DIGITAL METER USAGE 4   Connect the red meter lead to the positive (+) terminal of a battery and the black meter lead to the negative (-) terminal of a battery. The meter reads the voltage difference between the leads.
DIGITAL METER USAGE 5   This jump start battery unit measures 13.151 volts with the meter set on autoranging on the DC voltage scale.
DIGITAL METER USAGE 6   Another meter (Fluke 87 III) displays four digits when measuring the voltage of the battery jump start unit.
DIGITAL METER USAGE 7   To measure resistance turn the rotary dial to the ohm (Ω) symbol. With the meter leads separated, the meter display reads OL (over limit).
DIGITAL METER USAGE 8   The meter can read your own body resistance if you grasp the meter lead terminals with your fingers. The reading on the display indicates 196.35 kΩ.
DIGITAL METER USAGE 9   When measuring anything; be sure to read the symbol on the meter face. In this case, the meter is reading 291.10 kΩ.
DIGITAL METER USAGE 10   A meter set on ohms can be used to check the resistance of a light bulb filament. In this case, the meter reads 3.15 ohms. If the bulb were bad (filament open), the meter would display OL.
DIGITAL METER USAGE 11   A digital meter set to read ohms should measure 0.00 as shown when the meter leads are touched together.
DIGITAL METER USAGE 12   The large letter V means volts and the wavy symbol over the V means that the meter measures alternating current (AC) voltage if this position is selected.
DIGITAL METER USAGE 13   The next symbol is a V with a dotted and a straight line overhead. This symbol stands for direct current (DC) volts. This position is most used for automotive service.
DIGITAL METER USAGE 14   The symbol mV indicates millivolts or 1/1000 of a volt (0.001). The solid and dashed line above the mV means DC mV.
DIGITAL METER USAGE 15   The rotary switch is turned to Ω (ohms) unit of resistance measure. The symbol to the left of the Ω symbol is the beeper or continuity indicator.
DIGITAL METER USAGE 16   Notice that AUTO is in the upper left and the MΩ is in the lower right. This MΩ means megaohms or that the meter is set to read in millions of ohms.
DIGITAL METER USAGE 17   The symbol shown is the symbol of a diode. In this position, the meter applies a voltage to a diode and the meter reads the voltage drop across the junction of a diode.
DIGITAL METER USAGE 18   One of the most useful features of this meter is the MIN/MAX feature. By pushing the MIN/MAX button, the meter will be able to display the highest (MAX) and the lowest (MIN) reading.
DIGITAL METER USAGE 19   Pushing the MIN/MAX button puts the meter into record mode. Note the 100 mS and “REC” on the display. In this position, the meter is capturing any voltage charge that lasts 100 mS (0.1 sec) or longer.
DIGITAL METER USAGE 20   To increase the range of the meter touch the range button. Now the meter is set to read voltage up to 40 volts DC.
DIGITAL METER USAGE 21   Pushing the range button one more time changes the meter scale to the 400-voltage range. Notice that the decimal point has moved to the right.
DIGITAL METER USAGE 22   Pushing the range button again changes the meter to the 4000-volt range. This range is not suitable to use in automotive applications.
DIGITAL METER USAGE 23   By pushing and holding the range button, the meter will reset to autorange. Autorange is the preferred setting for most automotive measurements except when using MIN/MAX record mode.
FREQUENTLY ASKED QUESTION ,[object Object],[object Object],? BACK TO  PRESENTATION 1. The component or circuit must be disconnected from any electrical circuit while the resistance is being measured. 2. Because the meter itself applies a voltage (even though it is relatively low), a meter set to measure ohms can damage electronic circuits. Computer or electronic chips can be easily damaged if subjected to only a few milliamperes of current, similar to the amount an ohmmeter applies when a resistance measurement is being performed.
TECH TIP ,[object Object],[object Object],BACK TO  PRESENTATION ,[object Object],[object Object],[object Object],[object Object],[object Object]
FREQUENTLY ASKED QUESTION ,[object Object],[object Object],? BACK TO  PRESENTATION
TECH TIP ,[object Object],[object Object],BACK TO  PRESENTATION ,[object Object],[object Object],[object Object],[object Object]
TECH TIP ,[object Object],[object Object],BACK TO  PRESENTATION ,[object Object],[object Object]
TECH TIP ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],BACK TO  PRESENTATION ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
SAFETY TIP ,[object Object],[object Object],BACK TO  PRESENTATION ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]

Mais conteúdo relacionado

Mais procurados

U 4 ramp digital voltmeter
U 4 ramp digital voltmeterU 4 ramp digital voltmeter
U 4 ramp digital voltmeter
vmspraneeth
 

Mais procurados (20)

half wave, full wave, pushpull single pahse inverter and 3 phase inverter
half wave, full wave, pushpull single pahse inverter and 3 phase inverterhalf wave, full wave, pushpull single pahse inverter and 3 phase inverter
half wave, full wave, pushpull single pahse inverter and 3 phase inverter
 
Resistors: Types and Uses
Resistors: Types and UsesResistors: Types and Uses
Resistors: Types and Uses
 
Unit 03 Construction & Operation of Watt meter & Energy meter
Unit   03 Construction & Operation of Watt meter & Energy meterUnit   03 Construction & Operation of Watt meter & Energy meter
Unit 03 Construction & Operation of Watt meter & Energy meter
 
Concept of Digital measurement, block Diagram & study of Voltmeter
Concept of Digital measurement, block Diagram & study of VoltmeterConcept of Digital measurement, block Diagram & study of Voltmeter
Concept of Digital measurement, block Diagram & study of Voltmeter
 
ADC & DAC
ADC & DACADC & DAC
ADC & DAC
 
Classification (Analog instruments)
 Classification (Analog instruments) Classification (Analog instruments)
Classification (Analog instruments)
 
Maxwell bridge and its types
Maxwell bridge and its types Maxwell bridge and its types
Maxwell bridge and its types
 
Potentiometer
PotentiometerPotentiometer
Potentiometer
 
Digital voltmeter
Digital voltmeterDigital voltmeter
Digital voltmeter
 
Digital multimeters
Digital multimetersDigital multimeters
Digital multimeters
 
POWER ELECTRONICS LAB MANUAL, DR. B G SHIVALEELAVATHI, JSSATEB
POWER ELECTRONICS LAB MANUAL, DR. B G SHIVALEELAVATHI, JSSATEBPOWER ELECTRONICS LAB MANUAL, DR. B G SHIVALEELAVATHI, JSSATEB
POWER ELECTRONICS LAB MANUAL, DR. B G SHIVALEELAVATHI, JSSATEB
 
Introduction to electrical measurements
Introduction to electrical measurementsIntroduction to electrical measurements
Introduction to electrical measurements
 
Measurement of frequency
Measurement of frequencyMeasurement of frequency
Measurement of frequency
 
Unit 3
Unit 3Unit 3
Unit 3
 
DC potentiometers
DC potentiometersDC potentiometers
DC potentiometers
 
Unit 2 signal generators
Unit 2 signal generatorsUnit 2 signal generators
Unit 2 signal generators
 
Resistance Measurement instruments
Resistance Measurement instrumentsResistance Measurement instruments
Resistance Measurement instruments
 
Basics Of Energy Matering And Fraud Detection
Basics Of Energy Matering And Fraud DetectionBasics Of Energy Matering And Fraud Detection
Basics Of Energy Matering And Fraud Detection
 
Transformer Protection using PLC
Transformer Protection using PLCTransformer Protection using PLC
Transformer Protection using PLC
 
U 4 ramp digital voltmeter
U 4 ramp digital voltmeterU 4 ramp digital voltmeter
U 4 ramp digital voltmeter
 

Destaque

Halderman ch044 lecture
Halderman ch044 lectureHalderman ch044 lecture
Halderman ch044 lecture
mcfalltj
 
Halderman ch058 lecture
Halderman ch058 lectureHalderman ch058 lecture
Halderman ch058 lecture
mcfalltj
 
Chapter 35
Chapter 35Chapter 35
Chapter 35
mcfalltj
 
Halderman ch039 lecture
Halderman ch039 lectureHalderman ch039 lecture
Halderman ch039 lecture
mcfalltj
 
AP Physics - Chapter 20 Powerpoint
AP Physics - Chapter 20 PowerpointAP Physics - Chapter 20 Powerpoint
AP Physics - Chapter 20 Powerpoint
Mrreynon
 
Electricity.Electronics Ch20
Electricity.Electronics Ch20Electricity.Electronics Ch20
Electricity.Electronics Ch20
Nisa Sho
 

Destaque (17)

Halderman ch044 lecture
Halderman ch044 lectureHalderman ch044 lecture
Halderman ch044 lecture
 
Ev presentation for teca marketing group 2012
Ev presentation for teca marketing group 2012Ev presentation for teca marketing group 2012
Ev presentation for teca marketing group 2012
 
Battery
BatteryBattery
Battery
 
Halderman ch058 lecture
Halderman ch058 lectureHalderman ch058 lecture
Halderman ch058 lecture
 
Chapter 35
Chapter 35Chapter 35
Chapter 35
 
Lecture note e2063
Lecture note e2063Lecture note e2063
Lecture note e2063
 
Halderman ch039 lecture
Halderman ch039 lectureHalderman ch039 lecture
Halderman ch039 lecture
 
AP Physics - Chapter 20 Powerpoint
AP Physics - Chapter 20 PowerpointAP Physics - Chapter 20 Powerpoint
AP Physics - Chapter 20 Powerpoint
 
Electricity.Electronics Ch20
Electricity.Electronics Ch20Electricity.Electronics Ch20
Electricity.Electronics Ch20
 
Chap70
Chap70Chap70
Chap70
 
Study of Permanent Magnent Synchronous Macnine
Study of Permanent Magnent Synchronous MacnineStudy of Permanent Magnent Synchronous Macnine
Study of Permanent Magnent Synchronous Macnine
 
Modeling and simulation of pmsm
Modeling and simulation of pmsmModeling and simulation of pmsm
Modeling and simulation of pmsm
 
Super Conductors
Super ConductorsSuper Conductors
Super Conductors
 
Types of insulator
Types of insulatorTypes of insulator
Types of insulator
 
class 10 chapter 12 - Electricity
class 10 chapter 12 - Electricityclass 10 chapter 12 - Electricity
class 10 chapter 12 - Electricity
 
Complete analysis of Mahindra & Mahindra
Complete analysis of Mahindra & MahindraComplete analysis of Mahindra & Mahindra
Complete analysis of Mahindra & Mahindra
 
Concept of energy transmission & distribution
Concept of energy transmission & distribution Concept of energy transmission & distribution
Concept of energy transmission & distribution
 

Semelhante a Halderman ch042 lecture

Chapter 34
Chapter 34Chapter 34
Chapter 34
mcfalltj
 
How to use a digital multimeter
How to use a digital multimeterHow to use a digital multimeter
How to use a digital multimeter
Jim Licht
 
Testing components
Testing componentsTesting components
Testing components
vietem0610
 
D:\Edtech 2\Day5 Lesson11 N0ss
D:\Edtech 2\Day5 Lesson11 N0ssD:\Edtech 2\Day5 Lesson11 N0ss
D:\Edtech 2\Day5 Lesson11 N0ss
Arnold Dela Peña
 
Ser2200 linpwrsuppyspecsappnote
Ser2200 linpwrsuppyspecsappnoteSer2200 linpwrsuppyspecsappnote
Ser2200 linpwrsuppyspecsappnote
Pawar Chander
 
Electrical workshop module4
Electrical workshop module4Electrical workshop module4
Electrical workshop module4
rosehassan
 

Semelhante a Halderman ch042 lecture (20)

Chapter 34
Chapter 34Chapter 34
Chapter 34
 
How to use a digital multimeter
How to use a digital multimeterHow to use a digital multimeter
How to use a digital multimeter
 
Basicelectricalmeasuringinstruments 160111044802
Basicelectricalmeasuringinstruments 160111044802Basicelectricalmeasuringinstruments 160111044802
Basicelectricalmeasuringinstruments 160111044802
 
Basic electrical measuring instruments
Basic electrical measuring instrumentsBasic electrical measuring instruments
Basic electrical measuring instruments
 
Digitalvoltmeterppt 120914
Digitalvoltmeterppt 120914Digitalvoltmeterppt 120914
Digitalvoltmeterppt 120914
 
Ammeter and voltmeter
Ammeter and voltmeterAmmeter and voltmeter
Ammeter and voltmeter
 
Project Report
Project ReportProject Report
Project Report
 
FUNDAMENTAL OF VOLTAGE AND CURRENT
FUNDAMENTAL OF VOLTAGE AND CURRENTFUNDAMENTAL OF VOLTAGE AND CURRENT
FUNDAMENTAL OF VOLTAGE AND CURRENT
 
Testing components
Testing componentsTesting components
Testing components
 
D:\Edtech 2\Day5 Lesson11 N0ss
D:\Edtech 2\Day5 Lesson11 N0ssD:\Edtech 2\Day5 Lesson11 N0ss
D:\Edtech 2\Day5 Lesson11 N0ss
 
Ser2200 linpwrsuppyspecsappnote
Ser2200 linpwrsuppyspecsappnoteSer2200 linpwrsuppyspecsappnote
Ser2200 linpwrsuppyspecsappnote
 
Series2200 app note
Series2200 app noteSeries2200 app note
Series2200 app note
 
TESTING & MEASURING INSTRUMENTS by Meco
TESTING & MEASURING INSTRUMENTS by Meco TESTING & MEASURING INSTRUMENTS by Meco
TESTING & MEASURING INSTRUMENTS by Meco
 
Datasheet profitest mbase_mtech (1)
Datasheet profitest mbase_mtech (1)Datasheet profitest mbase_mtech (1)
Datasheet profitest mbase_mtech (1)
 
EEE project.pptx
EEE project.pptxEEE project.pptx
EEE project.pptx
 
Electrical workshop module4
Electrical workshop module4Electrical workshop module4
Electrical workshop module4
 
Lab 2 multimeter
Lab 2 multimeterLab 2 multimeter
Lab 2 multimeter
 
Assignment2
Assignment2Assignment2
Assignment2
 
IRJET- Arduino based Single Phase Fault Detection System using IoT
IRJET- Arduino based Single Phase Fault Detection System using IoTIRJET- Arduino based Single Phase Fault Detection System using IoT
IRJET- Arduino based Single Phase Fault Detection System using IoT
 
CHapter 4 -Signal Conditioning.pptxyyhhhj
CHapter 4 -Signal Conditioning.pptxyyhhhjCHapter 4 -Signal Conditioning.pptxyyhhhj
CHapter 4 -Signal Conditioning.pptxyyhhhj
 

Mais de mcfalltj

Halderman ch108 lecture
Halderman ch108 lectureHalderman ch108 lecture
Halderman ch108 lecture
mcfalltj
 
Halderman ch107 lecture
Halderman ch107 lectureHalderman ch107 lecture
Halderman ch107 lecture
mcfalltj
 
Halderman ch106 lecture
Halderman ch106 lectureHalderman ch106 lecture
Halderman ch106 lecture
mcfalltj
 
Halderman ch105 lecture
Halderman ch105 lectureHalderman ch105 lecture
Halderman ch105 lecture
mcfalltj
 
Halderman ch103 lecture
Halderman ch103 lectureHalderman ch103 lecture
Halderman ch103 lecture
mcfalltj
 
Halderman ch101 lecture
Halderman ch101 lectureHalderman ch101 lecture
Halderman ch101 lecture
mcfalltj
 
Halderman ch099 lecture
Halderman ch099 lectureHalderman ch099 lecture
Halderman ch099 lecture
mcfalltj
 
Halderman ch097 lecture
Halderman ch097 lectureHalderman ch097 lecture
Halderman ch097 lecture
mcfalltj
 
Halderman ch096 lecture
Halderman ch096 lectureHalderman ch096 lecture
Halderman ch096 lecture
mcfalltj
 

Mais de mcfalltj (20)

Chap71
Chap71Chap71
Chap71
 
Chap72
Chap72Chap72
Chap72
 
Chap73
Chap73Chap73
Chap73
 
Chap74
Chap74Chap74
Chap74
 
Chap75
Chap75Chap75
Chap75
 
Chap76
Chap76Chap76
Chap76
 
Chap77
Chap77Chap77
Chap77
 
Chap78
Chap78Chap78
Chap78
 
Chap80
Chap80Chap80
Chap80
 
Chap81
Chap81Chap81
Chap81
 
Chap82
Chap82Chap82
Chap82
 
Halderman ch108 lecture
Halderman ch108 lectureHalderman ch108 lecture
Halderman ch108 lecture
 
Halderman ch107 lecture
Halderman ch107 lectureHalderman ch107 lecture
Halderman ch107 lecture
 
Halderman ch106 lecture
Halderman ch106 lectureHalderman ch106 lecture
Halderman ch106 lecture
 
Halderman ch105 lecture
Halderman ch105 lectureHalderman ch105 lecture
Halderman ch105 lecture
 
Halderman ch103 lecture
Halderman ch103 lectureHalderman ch103 lecture
Halderman ch103 lecture
 
Halderman ch101 lecture
Halderman ch101 lectureHalderman ch101 lecture
Halderman ch101 lecture
 
Halderman ch099 lecture
Halderman ch099 lectureHalderman ch099 lecture
Halderman ch099 lecture
 
Halderman ch097 lecture
Halderman ch097 lectureHalderman ch097 lecture
Halderman ch097 lecture
 
Halderman ch096 lecture
Halderman ch096 lectureHalderman ch096 lecture
Halderman ch096 lecture
 

Último

Jual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan Cytotec
Jual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan CytotecJual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan Cytotec
Jual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan Cytotec
ZurliaSoop
 
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pillsMifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Abortion pills in Kuwait Cytotec pills in Kuwait
 
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
daisycvs
 

Último (20)

Power point presentation on enterprise performance management
Power point presentation on enterprise performance managementPower point presentation on enterprise performance management
Power point presentation on enterprise performance management
 
Falcon's Invoice Discounting: Your Path to Prosperity
Falcon's Invoice Discounting: Your Path to ProsperityFalcon's Invoice Discounting: Your Path to Prosperity
Falcon's Invoice Discounting: Your Path to Prosperity
 
Katrina Personal Brand Project and portfolio 1
Katrina Personal Brand Project and portfolio 1Katrina Personal Brand Project and portfolio 1
Katrina Personal Brand Project and portfolio 1
 
Jual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan Cytotec
Jual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan CytotecJual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan Cytotec
Jual Obat Aborsi ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan Cytotec
 
Putting the SPARK into Virtual Training.pptx
Putting the SPARK into Virtual Training.pptxPutting the SPARK into Virtual Training.pptx
Putting the SPARK into Virtual Training.pptx
 
Rice Manufacturers in India | Shree Krishna Exports
Rice Manufacturers in India | Shree Krishna ExportsRice Manufacturers in India | Shree Krishna Exports
Rice Manufacturers in India | Shree Krishna Exports
 
PHX May 2024 Corporate Presentation Final
PHX May 2024 Corporate Presentation FinalPHX May 2024 Corporate Presentation Final
PHX May 2024 Corporate Presentation Final
 
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pillsMifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
Mifty kit IN Salmiya (+918133066128) Abortion pills IN Salmiyah Cytotec pills
 
Horngren’s Cost Accounting A Managerial Emphasis, Canadian 9th edition soluti...
Horngren’s Cost Accounting A Managerial Emphasis, Canadian 9th edition soluti...Horngren’s Cost Accounting A Managerial Emphasis, Canadian 9th edition soluti...
Horngren’s Cost Accounting A Managerial Emphasis, Canadian 9th edition soluti...
 
Buy gmail accounts.pdf buy Old Gmail Accounts
Buy gmail accounts.pdf buy Old Gmail AccountsBuy gmail accounts.pdf buy Old Gmail Accounts
Buy gmail accounts.pdf buy Old Gmail Accounts
 
Organizational Transformation Lead with Culture
Organizational Transformation Lead with CultureOrganizational Transformation Lead with Culture
Organizational Transformation Lead with Culture
 
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
 
joint cost.pptx COST ACCOUNTING Sixteenth Edition ...
joint cost.pptx  COST ACCOUNTING  Sixteenth Edition                          ...joint cost.pptx  COST ACCOUNTING  Sixteenth Edition                          ...
joint cost.pptx COST ACCOUNTING Sixteenth Edition ...
 
Lundin Gold - Q1 2024 Conference Call Presentation (Revised)
Lundin Gold - Q1 2024 Conference Call Presentation (Revised)Lundin Gold - Q1 2024 Conference Call Presentation (Revised)
Lundin Gold - Q1 2024 Conference Call Presentation (Revised)
 
Buy Verified TransferWise Accounts From Seosmmearth
Buy Verified TransferWise Accounts From SeosmmearthBuy Verified TransferWise Accounts From Seosmmearth
Buy Verified TransferWise Accounts From Seosmmearth
 
Falcon Invoice Discounting: Aviate Your Cash Flow Challenges
Falcon Invoice Discounting: Aviate Your Cash Flow ChallengesFalcon Invoice Discounting: Aviate Your Cash Flow Challenges
Falcon Invoice Discounting: Aviate Your Cash Flow Challenges
 
Falcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business GrowthFalcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business Growth
 
Over the Top (OTT) Market Size & Growth Outlook 2024-2030
Over the Top (OTT) Market Size & Growth Outlook 2024-2030Over the Top (OTT) Market Size & Growth Outlook 2024-2030
Over the Top (OTT) Market Size & Growth Outlook 2024-2030
 
Cannabis Legalization World Map: 2024 Updated
Cannabis Legalization World Map: 2024 UpdatedCannabis Legalization World Map: 2024 Updated
Cannabis Legalization World Map: 2024 Updated
 
Arti Languages Pre Seed Teaser Deck 2024.pdf
Arti Languages Pre Seed Teaser Deck 2024.pdfArti Languages Pre Seed Teaser Deck 2024.pdf
Arti Languages Pre Seed Teaser Deck 2024.pdf
 

Halderman ch042 lecture

  • 1. CIRCUIT TESTERS AND DIGITAL METERS 42
  • 2.
  • 3.
  • 5.
  • 6.
  • 7. Figure 42-1 A technician-made fused jumper lead, which is equipped with a red 10 ampere fuse. This fused jumper wire uses terminals for testing circuits at a connector instead of alligator clips.
  • 8.
  • 10.
  • 11. Figure 42-2 A 12 volt test light is attached to a good ground while probing for power.
  • 12. Figure 42-3 A test light can be used to locate an open in a circuit. Note that the test light is grounded at a different location than the circuit itself.
  • 13.
  • 14.
  • 15.
  • 16. Figure 42-4 A continuity light should not be used on computer circuits because the applied voltage can damage delicate electronic components or circuits.
  • 17.
  • 18.
  • 19.
  • 20. Figure 42-5 An LED test light can be easily made using low cost components and an old ink pen. With the 470 ohm resistor in series with the LED, this tester only draws 0.025 ampere (25 milliamperes) from the circuit being tested. This low current draw helps assure the technician that the circuit or component being tested will not be damaged by excessive current flow.
  • 22.
  • 23.
  • 24.
  • 25.
  • 26.
  • 27. Figure 42-6 A logic probe connected to the vehicle battery. When the tip probe is connected to a circuit, it can check for power, ground, or a pulse.
  • 28.
  • 29.
  • 30.
  • 32.
  • 33.
  • 34.
  • 35. Figure 42-7 Typical digital multimeter. The black meter lead always is placed in the COM terminal. The red meter test lead should be in the volt-ohm terminal except when measuring current in amperes.
  • 36. Chart 42-1 Common symbols and abbreviations used on digital meters.
  • 37.
  • 38.
  • 39.
  • 40.
  • 41. Figure 42-8 Typical digital multimeter (DMM) set to read DC volts.
  • 42. Figure 42-9 (a) A typical autoranging digital multimeter automatically selects the proper scale to read the voltage being tested. The scale selected is usually displayed on the meter face. Note that the display indicates “4,” meaning that this range can read up to 4 volts.
  • 43. Figure 42-9 (b) A typical autoranging digital multimeter automatically selects the proper scale to read the voltage being tested. The scale selected is usually displayed on the meter face.The range is now set to the 40 volt scale, meaning that the meter can read up to 40 volts on the scale. Any reading above this level will cause the meter to reset to a higher scale. If not set on autoranging, the meter display would indicate OL if a reading exceeds the limit of the scale selected.
  • 44.
  • 45.
  • 46.
  • 47.
  • 48.
  • 49.
  • 50.
  • 51.
  • 52.
  • 53. Figure 42-10 Using a digital multimeter set to read ohms (Ω) to test this light bulb. The meter reads the resistance of the filament.
  • 54. Figure 42-11 Many digital multimeters can have the display indicate zero to compensate for test lead resistance. (1) Connect leads in the V Ω and COM meter terminals. (2) Select the Ω scale. (3) Touch the two meter leads together. (4) Push the “zero” or “relative” button on the meter. (5) The meter display will now indicate zero ohms of resistance.
  • 55.
  • 56. Figure 42-12 Measuring the current flow required by a horn requires that the ammeter be connected to the circuit in series and the horn button be depressed by an assistant.
  • 58.
  • 59.
  • 60. Figure 42-14 An inductive ammeter clamp is used with all starting and charging testers to measure the current flow through the battery cables.
  • 61.
  • 62.
  • 63. Figure 42-15 A typical mini clamp-on-type digital multimeter. This meter is capable of measuring alternating current (AC) and direct current (DC) without requiring that the circuit be disconnected to install the meter in series. The jaws are simply placed over the wire and current flow through the circuit is displayed.
  • 64. DIODE CHECK, PULSE WIDTH, AND FREQUENCY
  • 65.
  • 66.
  • 67.
  • 68.
  • 69.
  • 70.
  • 71.
  • 73.
  • 74.
  • 75.
  • 76. Figure 42-17 Always look at the meter display when a measurement is being made, especially if using an autoranging meter.
  • 77. Chart 42-2 A conversion chart showing the decimal point location for the various prefixes.
  • 78.
  • 79. HOW TO READ DIGITAL METERS
  • 80.
  • 81.
  • 82. Chart 42-3 Sample meter readings using manually set and autoranging selection on the digital meter control.
  • 83. Chart 42-3 (continued) Sample meter readings using manually set and autoranging selection on the digital meter control.
  • 84.
  • 85. Figure 42-18 When reading AC voltage signals, a true RMS meter (such as a Fluke 87) provides a different reading than an average responding meter (such as a Fluke 88). The only place this difference is important is when a reading is to be compared with a specification.
  • 86.
  • 87.
  • 88.
  • 89.
  • 90. Figure 42-19 This meter display shows 052.2 AC volts. Notice that the zero beside the 5 indicates that the meter can read over 100 volts AC with a resolution of 0.1 volt.
  • 91.
  • 92.
  • 93.
  • 94.
  • 95. DIGITAL METER USAGE 1 For most electrical measurements, the black meter lead is inserted in the terminal labeled COM and the red meter lead is inserted into the terminal labeled V.
  • 96. DIGITAL METER USAGE 2 To use a digital meter, turn the power switch and select the unit of electricity to be measured. In this case, the rotary switch is turned to select DC volts. (V)
  • 97. DIGITAL METER USAGE 3 For most automotive electrical use, such as measuring battery voltage, select DC volts.
  • 98. DIGITAL METER USAGE 4 Connect the red meter lead to the positive (+) terminal of a battery and the black meter lead to the negative (-) terminal of a battery. The meter reads the voltage difference between the leads.
  • 99. DIGITAL METER USAGE 5 This jump start battery unit measures 13.151 volts with the meter set on autoranging on the DC voltage scale.
  • 100. DIGITAL METER USAGE 6 Another meter (Fluke 87 III) displays four digits when measuring the voltage of the battery jump start unit.
  • 101. DIGITAL METER USAGE 7 To measure resistance turn the rotary dial to the ohm (Ω) symbol. With the meter leads separated, the meter display reads OL (over limit).
  • 102. DIGITAL METER USAGE 8 The meter can read your own body resistance if you grasp the meter lead terminals with your fingers. The reading on the display indicates 196.35 kΩ.
  • 103. DIGITAL METER USAGE 9 When measuring anything; be sure to read the symbol on the meter face. In this case, the meter is reading 291.10 kΩ.
  • 104. DIGITAL METER USAGE 10 A meter set on ohms can be used to check the resistance of a light bulb filament. In this case, the meter reads 3.15 ohms. If the bulb were bad (filament open), the meter would display OL.
  • 105. DIGITAL METER USAGE 11 A digital meter set to read ohms should measure 0.00 as shown when the meter leads are touched together.
  • 106. DIGITAL METER USAGE 12 The large letter V means volts and the wavy symbol over the V means that the meter measures alternating current (AC) voltage if this position is selected.
  • 107. DIGITAL METER USAGE 13 The next symbol is a V with a dotted and a straight line overhead. This symbol stands for direct current (DC) volts. This position is most used for automotive service.
  • 108. DIGITAL METER USAGE 14 The symbol mV indicates millivolts or 1/1000 of a volt (0.001). The solid and dashed line above the mV means DC mV.
  • 109. DIGITAL METER USAGE 15 The rotary switch is turned to Ω (ohms) unit of resistance measure. The symbol to the left of the Ω symbol is the beeper or continuity indicator.
  • 110. DIGITAL METER USAGE 16 Notice that AUTO is in the upper left and the MΩ is in the lower right. This MΩ means megaohms or that the meter is set to read in millions of ohms.
  • 111. DIGITAL METER USAGE 17 The symbol shown is the symbol of a diode. In this position, the meter applies a voltage to a diode and the meter reads the voltage drop across the junction of a diode.
  • 112. DIGITAL METER USAGE 18 One of the most useful features of this meter is the MIN/MAX feature. By pushing the MIN/MAX button, the meter will be able to display the highest (MAX) and the lowest (MIN) reading.
  • 113. DIGITAL METER USAGE 19 Pushing the MIN/MAX button puts the meter into record mode. Note the 100 mS and “REC” on the display. In this position, the meter is capturing any voltage charge that lasts 100 mS (0.1 sec) or longer.
  • 114. DIGITAL METER USAGE 20 To increase the range of the meter touch the range button. Now the meter is set to read voltage up to 40 volts DC.
  • 115. DIGITAL METER USAGE 21 Pushing the range button one more time changes the meter scale to the 400-voltage range. Notice that the decimal point has moved to the right.
  • 116. DIGITAL METER USAGE 22 Pushing the range button again changes the meter to the 4000-volt range. This range is not suitable to use in automotive applications.
  • 117. DIGITAL METER USAGE 23 By pushing and holding the range button, the meter will reset to autorange. Autorange is the preferred setting for most automotive measurements except when using MIN/MAX record mode.
  • 118.
  • 119.
  • 120.
  • 121.
  • 122.
  • 123.
  • 124.

Notas do Editor

  1. Figure 42-1 A technician-made fused jumper lead, which is equipped with a red 10 ampere fuse. This fused jumper wire uses terminals for testing circuits at a connector instead of alligator clips.
  2. Figure 42-2 A 12 volt test light is attached to a good ground while probing for power.
  3. Figure 42-3 A test light can be used to locate an open in a circuit. Note that the test light is grounded at a different location than the circuit itself.
  4. Figure 42-4 A continuity light should not be used on computer circuits because the applied voltage can damage delicate electronic components or circuits.
  5. Figure 42-5 An LED test light can be easily made using low cost components and an old ink pen. With the 470 ohm resistor in series with the LED, this tester only draws 0.025 ampere (25 milliamperes) from the circuit being tested. This low current draw helps assure the technician that the circuit or component being tested will not be damaged by excessive current flow.
  6. Figure 42-6 A logic probe connected to the vehicle battery. When the tip probe is connected to a circuit, it can check for power, ground, or a pulse.
  7. Figure 42-7 Typical digital multimeter. The black meter lead always is placed in the COM terminal. The red meter test lead should be in the volt-ohm terminal except when measuring current in amperes.
  8. Chart 42-1 Common symbols and abbreviations used on digital meters.
  9. Figure 42-8 Typical digital multimeter (DMM) set to read DC volts.
  10. Figure 42-9 (a) A typical autoranging digital multimeter automatically selects the proper scale to read the voltage being tested. The scale selected is usually displayed on the meter face.Note that the display indicates “4,” meaning that this range can read up to 4 volts.
  11. Figure 42-9 (b) A typical autoranging digital multimeter automatically selects the proper scale to read the voltage being tested. The scale selected is usually displayed on the meter face.The range is now set to the 40 volt scale, meaning that the meter can read up to 40 volts on the scale. Any reading above this level will cause the meter to reset to a higher scale. If not set on autoranging, the meter display would indicate OL if a reading exceeds the limit of the scale selected.
  12. Figure 42-10 Using a digital multimeter set to read ohms (Ω) to test this light bulb. The meter reads the resistance of the filament.
  13. Figure 42-11 Many digital multimeters can have the display indicate zero to compensate for test lead resistance. (1) Connect leads in the V Ω and COM meter terminals. (2) Select the Ω scale. (3) Touch the two meter leads together. (4) Push the “zero” or “relative” button on the meter. (5) The meter display will now indicate zero ohms of resistance.
  14. Figure 42-12 Measuring the current flow required by a horn requires that the ammeter be connected to the circuit in series and the horn button be depressed by an assistant.
  15. Figure 42-14 An inductive ammeter clamp is used with all starting and charging testers to measure the current flow through the battery cables.
  16. Figure 42-15 A typical mini clamp-on-type digital multimeter. This meter is capable of measuring alternating current (AC) and direct current (DC) without requiring that the circuit be disconnected to install the meter in series. The jaws are simply placed over the wire and current flow through the circuit is displayed.
  17. Figure 42-17 Always look at the meter display when a measurement is being made, especially if using an autoranging meter.
  18. Chart 42-2 A conversion chart showing the decimal point location for the various prefixes.
  19. Chart 42-3 Sample meter readings using manually set and autoranging selection on the digital meter control.
  20. Chart 42-3 (continued) Sample meter readings using manually set and autoranging selection on the digital meter control.
  21. Figure 42-18 When reading AC voltage signals, a true RMS meter (such as a Fluke 87) provides a different reading than an average responding meter (such as a Fluke 88). The only place this difference is important is when a reading is to be compared with a specification.
  22. Figure 42-19 This meter display shows 052.2 AC volts. Notice that the zero beside the 5 indicates that the meter can read over 100 volts AC with a resolution of 0.1 volt.
  23. DIGITAL METER USAGE 1 For most electrical measurements, the black meter lead is inserted in the terminal labeled COM and the red meter lead is inserted into the terminal labeled V.
  24. DIGITAL METER USAGE 2 To use a digital meter, turn the power switch and select the unit of electricity to be measured. In this case, the rotary switch is turned to select DC volts. (V)
  25. DIGITAL METER USAGE 3 For most automotive electrical use, such as measuring battery voltage, select DC volts.
  26. DIGITAL METER USAGE 4 Connect the red meter lead to the positive (+) terminal of a battery and the black meter lead to the negative (-) terminal of a battery. The meter reads the voltage difference between the leads.
  27. DIGITAL METER USAGE 5 This jump start battery unit measures 13.151 volts with the meter set on autoranging on the DC voltage scale.
  28. DIGITAL METER USAGE 6 Another meter (Fluke 87 III) displays four digits when measuring the voltage of the battery jump start unit.
  29. DIGITAL METER USAGE 7 To measure resistance turn the rotary dial to the ohm (Ω) symbol. With the meter leads separated, the meter display reads OL (over limit).
  30. DIGITAL METER USAGE 8 The meter can read your own body resistance if you grasp the meter lead terminals with your fingers. The reading on the display indicates 196.35 kΩ.
  31. DIGITAL METER USAGE 9 When measuring anything; be sure to read the symbol on the meter face. In this case, the meter is reading 291.10 kΩ.
  32. DIGITAL METER USAGE 10 A meter set on ohms can be used to check the resistance of a light bulb filament. In this case, the meter reads 3.15 ohms. If the bulb were bad (filament open), the meter would display OL.
  33. DIGITAL METER USAGE 11 A digital meter set to read ohms should measure 0.00 as shown when the meter leads are touched together.
  34. DIGITAL METER USAGE 12 The large letter V means volts and the wavy symbol over the V means that the meter measures alternating current (AC) voltage if this position is selected.
  35. DIGITAL METER USAGE 13 The next symbol is a V with a dotted and a straight line overhead. This symbol stands for direct current (DC) volts. This position is most used for automotive service.
  36. DIGITAL METER USAGE 14 The symbol mV indicates millivolts or 1/1000 of a volt (0.001). The solid and dashed line above the mV means DC mV.
  37. DIGITAL METER USAGE 15 The rotary switch is turned to Ω (ohms) unit of resistance measure. The symbol to the left of the Ω symbol is the beeper or continuity indicator.
  38. DIGITAL METER USAGE 16 Notice that AUTO is in the upper left and the MΩ is in the lower right. This MΩ means megaohms or that the meter is set to read in millions of ohms.
  39. DIGITAL METER USAGE 17 The symbol shown is the symbol of a diode. In this position, the meter applies a voltage to a diode and the meter reads the voltage drop across the junction of a diode.
  40. DIGITAL METER USAGE 18 One of the most useful features of this meter is the MIN/MAX feature. By pushing the MIN/MAX button, the meter will be able to display the highest (MAX) and the lowest (MIN) reading.
  41. DIGITAL METER USAGE 19 Pushing the MIN/MAX button puts the meter into record mode. Note the 100 mS and “REC” on the display. In this position, the meter is capturing any voltage charge that lasts 100 mS (0.1 sec) or longer.
  42. DIGITAL METER USAGE 20 To increase the range of the meter touch the range button. Now the meter is set to read voltage up to 40 volts DC.
  43. DIGITAL METER USAGE 21 Pushing the range button one more time changes the meter scale to the 400-voltage range. Notice that the decimal point has moved to the right.
  44. DIGITAL METER USAGE 22 Pushing the range button again changes the meter to the 4000-volt range. This range is not suitable to use in automotive applications.
  45. DIGITAL METER USAGE 23 By pushing and holding the range button, the meter will reset to autorange. Autorange is the preferred setting for most automotive measurements except when using MIN/MAX record mode.