Pre SBRT workup, Imaging
and Contouring
Dr. Naveen Mummudi,
Dr. J P Agarwal
IAEA-RTC meet – May 2017
MDT
discussion
Pre-SBRT
work up
Simulation
Tumour
and OAR
contouring
Treatment
planning
and plan
evaluation
Treatment
delivery
Follow up
for toxicity
MDT / clinical forum
MDT / clinical forum
• Patients with stage I lung cancer are candidates for curative treatment
and can be divided into three major groups:
• Low-risk surgical patients - usually treated by lobectomy;
• High-risk surgical patients - treated with sublobar (segmental or wedge)
resection or SBRT; and
• Medically inoperable patients - treated with EBRT or SBRT
MDT / clinical forum
• Inoperable
• Majority
• Operable
• Patient preference
• Clinical trial setting
 Medical inoperability
 Defined as “the presence of co-morbid illnesses that
renders the patient at higher than acceptable risk of
surgical morbidity and mortality.”
 Competing risk scenario - where risk of death from
medical illnesses is balanced by the risk of death
from lung cancer.
Colice, Shafazand et al. 2007
Pre SBRT work up
• Metastatic workup
• Diagnosis – Pathological / Radiological
• Imaging – CT / PET CT / MR Brain
• Medical condition assessment
• Pulmonary reserve
• Cardiology status
• Other comorbid conditions
• Tumour characteristics
• Location – Peripheral / central / ultra central
Oncological assessment
• Imaging
• PET CT whole body / CECT Thorax
• MRI brain
• EUS-TBNA: ?role
• 2 prospective trials evaluating PET+/- EUS-TBNA
• Confirmation of diagnosis
• Pathological – CT guided/trans-bronchial
• Radiological – imaging characteristics
Oncological assessment
Oncological assessment
…developed a model that demonstrates that treating an SPN
without pathology is justified when the likelihood of
malignancy is 85%
Louie 2014
Medical assessment
• Pulmonary function
• GOLD – COPD
• ACCP recommendations
• Cardiac evaluation
• Charlson comorbidity index
Lung volumes - Spirometry
Spirometry
• Patients with advanced lung disease have decreased survival defined
by the severity of their disease.
• In patients with COPD, FEV 1 < 35%
predicts approximately 10% mortality
per year (50% 5-year survival).
Medical evaluation
• DLCO
• Cardiopulmonary Exercise Testing
• 6 minute walk test / Incremental shuttle walk test
• Split function test
• Ventilation/perfusion scinitigraphy
• Cardiac evaluation
• 2D ECHO
Algorithm for cardiac assessment
ERS/ESTS task force 2009
ERS/ESTS task force 2009
Charlson comorbidity index
Tumour characteristics
• Size
• Location of tumour
• Severe toxicity rates of 17% and
46% at 3 years for peripheral
and central lesions
Timmerman, 2003, Chest
McGarry, 2005, IJROBP
Glide-Hurst, 2014, J thorac dis
Tumour characteristics
Roesch, RO, 2016
Tumour characteristics
Tumour characteristics
Immobilization
• Accurately re-position patient
• Reduce/Minimize patient voluntary and involuntary motion
• Reduce/Minimize organ/target motion
• Abdominal compression
• Comfortable for long treatment
• Compatible with IGRT
• Not interfere with treatment beam
Body Pro-Lok TM frame Body Fix Abdominal Compression
Thermoplastic Long mask
Commercial devices
Abdominal compression belt
• Plastic board with two long slits on
the sides
• Blood pressure cuff, Velcro® mounted
under the board
• Adjustable, Velcro® covered belt
• Sewn-on ruler for consistent setup
Pneumatic Compression Belt
• Air inflation bulb
• Pressure gauge
• Non-Rigid
• Marking of the patient skin &
immobilization device
• Recording of the pressure
Immobilization/Simulation
• Careful positioning in the immobilization device, supporting the hands and
shoulders
• premedication with analgesia (e.g., to prevent shoulder pain)
• anxiolytic may be needed
• Scanning in TX Position
• CT, MR, PET-CT
• CT scan with ≤ 3 mm slice thickness
• Motion Management
• Abdominal Compression Plate
• Pressure Belt
• Body Immobilization
Respiratory motion
Causes artifacts during imaging acquisitions
Radiation delivery limitations
Limiting treatment planning
Treatment planning difficulty
When to manage respiratory motion?
AAPM Task Group 76: respiratory management techniques should be
considered if either of the following conditions occur –
• > 5 mm range of motion is observed in any direction
• Significant normal tissue sparing can be gained using respiration
management
26
The Management of Respiratory Motion in Radiation
Oncology; Report of AAPM Task Group 76 July 2006 by
American Association of Physicists in Medicine
Recommended Clinical Process for patients with
whom respiratory motion during RT is a concern
27
Methods to Account for Motion
• Motion-encompassing methods
• Respiratory gating methods
• Breath-hold methods
• Forced shallow breathing with abdominal compression
• Real-time tumor-tracking methods
CT Simulation
• Suppressed respiratory motion techniques
• Compression Paddle, Pressure Belt
• Free Breathing (FB) & Slow CT-Scanners
• Free Breathing & Fast CT-Scanners
• Breath-Hold (BH) CT-Scans
• Respiratory Correlated CT (4D-CT)
Motion Management Strategies
Method Technique
Incorporate all movements 4DCT or Slow CT
Freeze movement Breath hold
Intercept movement Gated Radiotherapy
Track or Chase the tumor Implanted markers and specialized
treatment delivery
30
Slow CT scanning
• Scanner operates at a particular couch position for longer than the respiratory cycle so that the
image of the tumor would show the full extent of respiratory motion.
• Yields a tumor-encompassing volume
• Limitation: respiratory motion will change between imaging and treatment;
• additional margins are required to account for these variations.
• One CT scan is obtained
• overall treatment process does not increase in complexity over that of a free-breathing CT scan
• Loss of resolution due to motion blurring, which potentially leads to larger observer errors in
tumor and OAR delineation.
• only recommended for lung tumors that are not involved with either the mediastinum or the chest wall.
• Increased dose of radiation from slow CT scanning compared with conventional CT scanning.
31
Inhale and exhale breath-hold CT
• Advantage: blurring caused by motion present during free breathing is
significantly reduced during breath-hold.
• But taking both inhale and exhale CT scans will increase scanning time and relies
on the patient’s ability to hold breath reproducibly.
• Two scans will be obtained; thus, image fusion and extra contouring are required.
• Dose calculation should be performed on the CT data set that is most appropriate
for the particular patient, e.g., exhale CT for patients generally spending more
time at exhale than inhale.
• The exhale scan will tend to underestimate the lung volumes and, hence,
overestimate the percentage of lung volume receiving a specific dose.
32
Respiratory-triggered CT scan
• Slice acquisition is triggered by a respiratory signal, such that slices are
only acquired in a pre-set phase of respiratory cycle.
• The result is a 3D image in which all the slices are acquired in the same
phase of breathing.
• A scan is acquired with the imaging beam on during the entire breathing
cycle and this is performed at all couch positions. Subsequently CT slices
are reconstructed at consecutive points of the breathing cycle.
33
4-D CT
Patient Training
• The ability to achieve reproducible breathing or breath-hold patterns is a
requirement for allowing the patient to proceed to simulation and treatment.
• Prior to the start of simulation, the patient should be made familiar with the
equipment and its purpose.
• A physicist or trained designee should perform the coaching and evaluation, at
least in the initial clinical implementation.
34
Different ways to acquire respiratory trace
• VARIAN : Real-Time Position Management System (RPM)
35
• ELEKTA : Active Breath Coordinator (ABC)
• SIEMENS : ANZAI
belt
RPM system
• Consists of a plastic marker block with six metallic
reflectors (3 cm apart for calibrating amplitude) which
is placed on patient’s abdomen between the xiphoid
and umbilicus.
• A infrared camera records the abdominal surface
motion.
• RPM software tracks the marker trajectory in real time
and calculates the respiratory phase on the basis of
observed amplitude.
• CT scanner and RPM system communicate during data
acquisition to indicate when beam is turned on or off.
36
Marker Block
RPM system can detect the motion of the marker block in vertical,
lateral and longitudinal dimensions.
37
4DCT
• 4DCT scans can be performed both in sequential and in helical
scanning modes —
• In sequential mode, beam is kept on during a breathing cycle at each
couch position
• In helical mode, beam is kept on during the entire scan, while the
pitch is very low.
• In both cases, this in effect provides a densely oversampled scan.
38
39
40
4DCT
• Typically, a total of 1000 –1500 images are acquired during a 4D-CT study.
Approximately 20 –25 images are reconstructed per slice, evenly distributed
throughout the respiratory period.
• Each reconstructed axial image represents the anatomy at a different instant
during the patient’s respiratory cycle.
• On the basis of the temporal correlation between the surface motion and image
data acquisition, a specific respiratory phase is assigned to each image.
• An axial image at a given couch position is binned on the basis of its respiratory
phase. 41
42
Phase vs. Amplitude sorting
• Majority of the published 4D-C T techniques have used a time-based phase
sorting method for retrospectively gating image data.
• This is subject to misalignment due to varying inhale and exhale slopes,
periods, and amplitudes in the respiration trace.
• Rietzel et al. proposed an amplitude sorting method -- a constant amplitude on
the respiratory curve is chosen to designate the phase position.
• Although this method eliminates the possibility of misalignment, it increases the
potential for missing phase sets. If a certain amplitude is not reached in all cycles
of the recorded respiration trace, then that phase set cannot be created without
a gap in the volume.
43
Rietzel E, Pan TS, C hen GTY. 4D CT: Image formation
and clinical protocol. Med Phys. 2005;32(4):874-889
4DCT
• 4D CT scan not only reduces motion artifacts, but also gives the
tumor/organ motion information.
• There may still be blurring artifacts in each slice caused by the
residual motion within the slice acquisition time, but shorter the slice
acquisition time, smaller the artifacts.
• 4D CT scan is NOT really 4D
Temporal information is mapped onto one breathing cycle.
Irregular respiration will cause artifacts in 4D CT images.
Breath coaching is always needed.
44
4DCT
• 4DCT scanning procedure of the entire thorax takes about 90 s.
• Radiation exposure from 4DCT acquisition is approximately six times
the dose of a single conventional helical CT scan (range 0.02 - 0.09 Gy)
• Generation of individualized and usually smaller target volumes
derived from 4DCT scans in comparison to standard PTVs justifies this
additional radiation exposure
45
46
H. Hof et al. / Radiotherapy and Oncology 93 (2009) 419–423
Conventional vs. 4D based target definition
PTV4D is not only smaller in most parts but also extends to areas
not covered by PTVconv 47
Using 4DCT data to draw Target
• A composite target volume is the union of individual target volumes at different
instants in time.
• The standard approach would include contouring GTVs on all binned data sets
(usually 10).
• Alternatively, contour GTV on the volumes at end-inhale and end-exhale and fuse
them. The composite contours from these extreme data sets are then overlaid
onto each breathing phase and visually verify whether the composite volume
includes all instances of GTVs at other respiratory phases.
• Strategy of contouring extreme tumor positions will fail whenever the size of the
tumor is smaller than its motion amplitude.
48
4-D CT: Generating Target Volumes
49
Different Target Volumes derived from GTV
Target definition according to the
recommendations in ICRU Report 62
ICRU Report 62 recommends use of an internal target volume (ITV)
to account for variations in size, shape, and position of the CTV
International Commission on Radiation Units and Measurements.
ICRU report 62: Prescribing, recording, and reporting photon beam
therapy (Supplement to ICRU report 50). Bethesda, MD: ICRU 1999
Maximal Intensity Projection (MIP)
• When a significant density difference exists between the tumor and
surrounding tissue, it may be exploited to decrease the contouring
workload.
• A Maximal Intensity Projection (MIP) is automatically generated from
the entire 4D-CT by assigning each voxel the greatest Hounsfield unit
value from all corresponding voxels over the multiple respiratory phase
image data.
• For a lung tumor, this results in identification and localization of high-
density tumor voxels compared with lower density lung tissue voxels.
50
Failure of MIP technique
51
Rietzel et al. Maximum-intensity volumes for fast contouring of lung tumors
Including respiratory motion in 4dct planning; Int. J. Radiation Oncology Biol.
Phys., Vol. 71, No. 4, pp. 1245–1252, 2008
While contouring using MIP technique one needs to be
careful for nodal volumes within the hilum or
mediastinum, tumors located near the diaphragm, and
tumors surrounded by atelectasis
Window effect
For Parenchymal disease: W=1600 L= -600
For Mediastinal disease: W=400 L=20
These correlate best with pathological tumor sizes
Tumor and OAR Delineation
• If 4DCT unavailable or unsuitable free-breathing helical images can be
used for treatment planning
• In selected patients intravenous CT contrast may help to identify the GTV
• When PET imaging is available (either in the diagnostic or preferably, the
treatment position) it is fused to the exhale CT and may be used to inform
the contouring process, especially in instances where there is a
neighbouring region of atelectasis
Planning Target Volume (PTV)
• For the remaining uncertainty a setup margin is required
• A uniform expansion of 5 mm is typically applied to the 4DCT based ITV to generate
the PTV
• In certain circumstances, for example OAR proximity, this may be individualized
OAR delineation
Atlas of lung, esophagus, and spinal cord
Int J Radiat Oncol Biol Phys. 2011 81(5):1442-57
Recommendation based on Timmerman et al for RTOG 0236 and RTOG 0618,
Bezjak et al for RTOG 0813
Atlases for Organs at Risk (OARs) in
Thoracic Radiation Therapy
• Feng-Ming (Spring) Kong MD PhD
• Leslie Quint MD
• Mitchell Machtay MD
• Jeffrey Bradley MD
Lungs
• Both lungs should be contoured using pulmonary windows.
• The right and left lungs can be contoured separately
• Total lung for dosimetry
• All inflated and collapsed, fibrotic and emphysematic lungs should be
contoured.
• Hilar region and trachea/main bronchus should not be included in this
structure
Esophagus
• Begin at the level just below the cricoid to its entrance to the stomach
at GE junction.
• Contoured using mediastinal window/level on CT to correspond to the
mucosal, submucosa, and all muscular layers out to the fatty adventitia.
• Barium swallow for better delineation.
Spinal cord
• Bony limits of the spinal canal.
• Start at the level just below cricoid to the bottom of L2
• base of skull for apex tumors and continuing
• Neuroformanines should not be included.
Begin below the level of post-cricoid region
Include the entire spinal canal
Barium swallow allows better delineation of esophagus
Barium swallow
Inferiorly till the GE junction
Pericardium
• Includes pericardial fatty tissue, part of great vessels, normal recesses,
pericardial effusion (if present) and heart chambers.
• Starts at one slice above the top of aortic arch, ends at the last slice of
heart apex at diaphragm.
• Pericardium includes the heart.
PericardiumSVC
Begin one slice above the top of aortic arch
PericardiumArch of aorta
PericardiumAscending aorta
Pulmonary A
Pulmonary V
Descending aorta
Great vessels
• Contoured separately from the heart, using mediastinal windowing to
correspond to the vascular wall and all muscular layers out to the fatty
adventitia.
• Start at least 3 cm above the superior extent of the PTV and up to at
least 3 cm below the inferior extent of the PTV.
• For right sided tumors, SVC will be contoured, and
• For left sided tumors, the aorta will be contoured.
• The ipsilateral PA will be delineated for tumor of either side.
Pulmonary AAscending aorta
Descending Aorta
SVC
IVC
Heart
• Contoured along with the pericardial sac.
• Superiorly begin at the level of the inferior aspect of the pulmonary
artery passing the midline and extend inferiorly to the apex of the heart.
Start at the level of the inferior aspect of
the pulmonary artery passing the midline
Heart and pericardium are to be overlapped
Proximal bronchial tree
• Includes the
• distal 2 cm of the trachea,
• the carina,
• the right and left mainstem bronchi,
• the right and left upper lobe bronchi,
• the intermedius bronchus,
• the right middle lobe bronchus,
• the lingular bronchus, and
• the right and left lower lobe bronchi.
Proximal Bronchus Tree Ends
at the level of lobar bronchus bifurcating
into segmental bronchus
Brachial plexus
• Required for patients with tumors
of upper lobes.
• Only the ipsilateral brachial plexus
is contoured.
• Includes the spinal nerves exiting
the neuroforamine from top of C5
to top of T2.
• Should extend at least 3 cm above
the PTV.
Identify anterior and middle scalene muscles from
C5 to insertion onto the first rib.
Start at the neural foramina from
C5 to T1
Extend from the lateral aspect of the spinal canal to the
small space between the anterior and middle scalene
muscles.
Contour the trunks of the brachial plexus between the
anterior and middle scalene muscles.
Where no neural foramen is present, contour only
the space between the anterior and middle scalene muscles
Contour the trunks of the brachial plexus between the
anterior and middle scalene muscles.
Eventually the middle scalene will end in the
region of the subclavian neurovascular bundle.
Vein, artery, and nerve (VAN, anterior to posterior) will go
over the 1st rib and under the clavicle
Contour the brachial plexus as the posterior aspect of
the neurovascular bundle.
IV contrast greatly facilitates contouring
The first and second ribs serve as the medial limit
Chest wall
• Autosegmented from the ipsilateral lung with a 2-cm expansion in the
lateral, anterior, and posterior directions.
• Anteriorly and medially, it ends at the edge of the sternum.
• Posteriorly and medially, it stops at the edge of the vertebral body with inclusion
of the spinal nerve root exit site.
• Includes intercostal muscles, nerves exclude vertebrate bodies, sternum
and skin.
This recommendation was based on
1. Kong et al, Int J Radiat Oncol Biol Phys. 2010 Oct 7.
2. “CW2cm consistently enabled better prediction of CW toxicity than CW3cm” in Mutter
et al, Int J Radiat Oncol Biol Phys. 2011 Aug 23.
Evaluation and imaging for lung SBRT
Evaluation and imaging for lung SBRT

Mais conteúdo relacionado

Mais procurados

Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...
Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...
Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...Abhishek Soni
 
EPID AND CBCT ON RADIATION THERAPY
EPID AND CBCT ON RADIATION THERAPYEPID AND CBCT ON RADIATION THERAPY
EPID AND CBCT ON RADIATION THERAPYanju k.v.
 
Imrt Treatment Planning And Dosimetry
Imrt Treatment Planning And DosimetryImrt Treatment Planning And Dosimetry
Imrt Treatment Planning And Dosimetryfondas vakalis
 
ICRU reports 50 and 62
ICRU reports 50 and 62ICRU reports 50 and 62
ICRU reports 50 and 62Bharti Devnani
 
4 dcrt, FourDimensionalConventionalRadiationTreatment
4 dcrt, FourDimensionalConventionalRadiationTreatment4 dcrt, FourDimensionalConventionalRadiationTreatment
4 dcrt, FourDimensionalConventionalRadiationTreatmentNIMESHDAHIMA
 
Plan evaluation in RADIOTHERAPY
Plan evaluation in RADIOTHERAPYPlan evaluation in RADIOTHERAPY
Plan evaluation in RADIOTHERAPYKanhu Charan
 
Radiotherapy in ca esophagus
Radiotherapy in ca esophagusRadiotherapy in ca esophagus
Radiotherapy in ca esophagusIsha Jaiswal
 
Forward imrt in breast radiotherapy
Forward imrt in breast radiotherapyForward imrt in breast radiotherapy
Forward imrt in breast radiotherapyNilesh Kucha
 
Plan evaluation in Radiotherapy- Dr Kiran
Plan evaluation in Radiotherapy- Dr KiranPlan evaluation in Radiotherapy- Dr Kiran
Plan evaluation in Radiotherapy- Dr KiranKiran Ramakrishna
 
Intensity Modulated Radiation Therapy (IMRT)
Intensity Modulated Radiation Therapy (IMRT)Intensity Modulated Radiation Therapy (IMRT)
Intensity Modulated Radiation Therapy (IMRT)Dilshad KP
 
Hemibody and total body radiation
Hemibody and total body radiationHemibody and total body radiation
Hemibody and total body radiationDhiman Das
 

Mais procurados (20)

Gap correction
Gap correctionGap correction
Gap correction
 
Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...
Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...
Three dimensional conformal radiotherapy - 3D-CRT and IMRT - Intensity modula...
 
EPID AND CBCT ON RADIATION THERAPY
EPID AND CBCT ON RADIATION THERAPYEPID AND CBCT ON RADIATION THERAPY
EPID AND CBCT ON RADIATION THERAPY
 
Imrt Treatment Planning And Dosimetry
Imrt Treatment Planning And DosimetryImrt Treatment Planning And Dosimetry
Imrt Treatment Planning And Dosimetry
 
4dct (2012)
4dct (2012)4dct (2012)
4dct (2012)
 
ICRU reports 50 and 62
ICRU reports 50 and 62ICRU reports 50 and 62
ICRU reports 50 and 62
 
Lung sbrt ppt
Lung  sbrt pptLung  sbrt ppt
Lung sbrt ppt
 
4 dcrt, FourDimensionalConventionalRadiationTreatment
4 dcrt, FourDimensionalConventionalRadiationTreatment4 dcrt, FourDimensionalConventionalRadiationTreatment
4 dcrt, FourDimensionalConventionalRadiationTreatment
 
Isodose lines
Isodose linesIsodose lines
Isodose lines
 
Plan evaluation in RADIOTHERAPY
Plan evaluation in RADIOTHERAPYPlan evaluation in RADIOTHERAPY
Plan evaluation in RADIOTHERAPY
 
Treatment plannings i kiran
Treatment plannings i   kiranTreatment plannings i   kiran
Treatment plannings i kiran
 
TSET
TSETTSET
TSET
 
4D Radiotherapy
4D Radiotherapy4D Radiotherapy
4D Radiotherapy
 
Radiotherapy in ca esophagus
Radiotherapy in ca esophagusRadiotherapy in ca esophagus
Radiotherapy in ca esophagus
 
Forward imrt in breast radiotherapy
Forward imrt in breast radiotherapyForward imrt in breast radiotherapy
Forward imrt in breast radiotherapy
 
Plan evaluation in Radiotherapy- Dr Kiran
Plan evaluation in Radiotherapy- Dr KiranPlan evaluation in Radiotherapy- Dr Kiran
Plan evaluation in Radiotherapy- Dr Kiran
 
Intensity Modulated Radiation Therapy (IMRT)
Intensity Modulated Radiation Therapy (IMRT)Intensity Modulated Radiation Therapy (IMRT)
Intensity Modulated Radiation Therapy (IMRT)
 
Modern Radiotherapy
Modern RadiotherapyModern Radiotherapy
Modern Radiotherapy
 
Hemibody and total body radiation
Hemibody and total body radiationHemibody and total body radiation
Hemibody and total body radiation
 
Total body irradiation
Total body irradiationTotal body irradiation
Total body irradiation
 

Semelhante a Evaluation and imaging for lung SBRT

Motion management techniques in RT
Motion management techniques in RT Motion management techniques in RT
Motion management techniques in RT Nidhil Krishna
 
Respiration motion management
Respiration motion managementRespiration motion management
Respiration motion managementKiran Ramakrishna
 
Motion Management in Lung Cancer Radiotherapy
Motion Management in Lung Cancer RadiotherapyMotion Management in Lung Cancer Radiotherapy
Motion Management in Lung Cancer RadiotherapyJyotirup Goswami
 
Role of SBRT in lung cancer
Role of SBRT in lung cancerRole of SBRT in lung cancer
Role of SBRT in lung cancerDrAyush Garg
 
RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)
RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)
RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)DrAnkitaPatel
 
Diaphragm Ultrasound as a Novel Guide of Weaning from Invasive Ventilation
Diaphragm Ultrasound as a Novel Guide of Weaning from Invasive VentilationDiaphragm Ultrasound as a Novel Guide of Weaning from Invasive Ventilation
Diaphragm Ultrasound as a Novel Guide of Weaning from Invasive VentilationGamal Agmy
 
ctaheadandneckyash-190917182954.pdf
ctaheadandneckyash-190917182954.pdfctaheadandneckyash-190917182954.pdf
ctaheadandneckyash-190917182954.pdfBrian Sells
 
Anaesthesia for thoracoscopic surgery
Anaesthesia for thoracoscopic surgeryAnaesthesia for thoracoscopic surgery
Anaesthesia for thoracoscopic surgeryZIKRULLAH MALLICK
 
LungCancerSlides.pptx
LungCancerSlides.pptxLungCancerSlides.pptx
LungCancerSlides.pptxHesocaHux
 
Journal Presentation on article Comparative efficacy of different combination...
Journal Presentation on article Comparative efficacy of different combination...Journal Presentation on article Comparative efficacy of different combination...
Journal Presentation on article Comparative efficacy of different combination...Shubham Jain
 
Radiotherapy in Cervical Cancers1.ppt
Radiotherapy in Cervical Cancers1.pptRadiotherapy in Cervical Cancers1.ppt
Radiotherapy in Cervical Cancers1.pptNeetumishti Chadha
 

Semelhante a Evaluation and imaging for lung SBRT (20)

Motion management techniques in RT
Motion management techniques in RT Motion management techniques in RT
Motion management techniques in RT
 
Motion Management in Radiation Therapy
Motion Management in Radiation TherapyMotion Management in Radiation Therapy
Motion Management in Radiation Therapy
 
Respiration motion management
Respiration motion managementRespiration motion management
Respiration motion management
 
Motion Management in Lung Cancer Radiotherapy
Motion Management in Lung Cancer RadiotherapyMotion Management in Lung Cancer Radiotherapy
Motion Management in Lung Cancer Radiotherapy
 
Role of SBRT in lung cancer
Role of SBRT in lung cancerRole of SBRT in lung cancer
Role of SBRT in lung cancer
 
RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)
RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)
RADIOTHERAPY IN CARCINOMA BREAST (EARLY AND LOCALLY ADVANCED)
 
Diaphragm Ultrasound as a Novel Guide of Weaning from Invasive Ventilation
Diaphragm Ultrasound as a Novel Guide of Weaning from Invasive VentilationDiaphragm Ultrasound as a Novel Guide of Weaning from Invasive Ventilation
Diaphragm Ultrasound as a Novel Guide of Weaning from Invasive Ventilation
 
Ct thorax
Ct thoraxCt thorax
Ct thorax
 
Igrt prostate
Igrt prostateIgrt prostate
Igrt prostate
 
Respiratory gating
Respiratory gatingRespiratory gating
Respiratory gating
 
ctaheadandneckyash-190917182954.pdf
ctaheadandneckyash-190917182954.pdfctaheadandneckyash-190917182954.pdf
ctaheadandneckyash-190917182954.pdf
 
CT Angiography Head and Neck
CT Angiography Head and NeckCT Angiography Head and Neck
CT Angiography Head and Neck
 
Anaesthesia for thoracoscopic surgery
Anaesthesia for thoracoscopic surgeryAnaesthesia for thoracoscopic surgery
Anaesthesia for thoracoscopic surgery
 
LungCancerSlides.pptx
LungCancerSlides.pptxLungCancerSlides.pptx
LungCancerSlides.pptx
 
Journal Presentation on article Comparative efficacy of different combination...
Journal Presentation on article Comparative efficacy of different combination...Journal Presentation on article Comparative efficacy of different combination...
Journal Presentation on article Comparative efficacy of different combination...
 
Cyberknife
Cyberknife Cyberknife
Cyberknife
 
Non small cell ca
Non small cell caNon small cell ca
Non small cell ca
 
Radiotherapy in Cervical Cancers1.ppt
Radiotherapy in Cervical Cancers1.pptRadiotherapy in Cervical Cancers1.ppt
Radiotherapy in Cervical Cancers1.ppt
 
Lung cancer treatment
Lung cancer treatment Lung cancer treatment
Lung cancer treatment
 
cervical cancer conformal radiotherapy planning (3D CRT)
cervical cancer conformal radiotherapy planning (3D CRT)cervical cancer conformal radiotherapy planning (3D CRT)
cervical cancer conformal radiotherapy planning (3D CRT)
 

Último

Call Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Amritsar Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Amritsar Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Amritsar Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Amritsar Just Call 8250077686 Top Class Call Girl Service AvailableDipal Arora
 
Top Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near Me
Top Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near MeTop Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near Me
Top Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near Mechennailover
 
💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...
💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...
💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...Sheetaleventcompany
 
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...tanya dube
 
Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...
Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...
Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...Anamika Rawat
 
Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...
Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...
Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...Sheetaleventcompany
 
8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In AhmedabadGENUINE ESCORT AGENCY
 
Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...
Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...
Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...khalifaescort01
 
Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...
Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...
Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...chetankumar9855
 
💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...
💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...
💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...khalifaescort01
 
Call Girls Mumbai Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Mumbai Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Mumbai Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Mumbai Just Call 8250077686 Top Class Call Girl Service AvailableDipal Arora
 
Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...
Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...
Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...parulsinha
 
Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426
Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426
Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426jennyeacort
 
Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...
Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...
Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...BhumiSaxena1
 
Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...
Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...
Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...adilkhan87451
 
Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...
Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...
Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...GENUINE ESCORT AGENCY
 
Call Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service AvailableDipal Arora
 

Último (20)

Call Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Hyderabad Just Call 8250077686 Top Class Call Girl Service Available
 
Call Girls Amritsar Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Amritsar Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Amritsar Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Amritsar Just Call 8250077686 Top Class Call Girl Service Available
 
Top Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near Me
Top Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near MeTop Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near Me
Top Rated Call Girls Kerala ☎ 8250092165👄 Delivery in 20 Mins Near Me
 
💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...
💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...
💚Call Girls In Amritsar 💯Anvi 📲🔝8725944379🔝Amritsar Call Girl No💰Advance Cash...
 
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
 
Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...
Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...
Andheri East ) Call Girls in Mumbai Phone No 9004268417 Elite Escort Service ...
 
Call Girls in Gagan Vihar (delhi) call me [🔝 9953056974 🔝] escort service 24X7
Call Girls in Gagan Vihar (delhi) call me [🔝  9953056974 🔝] escort service 24X7Call Girls in Gagan Vihar (delhi) call me [🔝  9953056974 🔝] escort service 24X7
Call Girls in Gagan Vihar (delhi) call me [🔝 9953056974 🔝] escort service 24X7
 
Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...
Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...
Call Girls Service Jaipur {9521753030} ❤️VVIP RIDDHI Call Girl in Jaipur Raja...
 
8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
8980367676 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
 
Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...
Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...
Call Girls Service Jaipur {9521753030 } ❤️VVIP BHAWNA Call Girl in Jaipur Raj...
 
Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...
Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...
Call Girl In Pune 👉 Just CALL ME: 9352988975 💋 Call Out Call Both With High p...
 
💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...
💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...
💕SONAM KUMAR💕Premium Call Girls Jaipur ↘️9257276172 ↙️One Night Stand With Lo...
 
Call Girls Mumbai Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Mumbai Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Mumbai Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Mumbai Just Call 8250077686 Top Class Call Girl Service Available
 
Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...
Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...
Independent Call Girls In Jaipur { 8445551418 } ✔ ANIKA MEHTA ✔ Get High Prof...
 
🌹Attapur⬅️ Vip Call Girls Hyderabad 📱9352852248 Book Well Trand Call Girls In...
🌹Attapur⬅️ Vip Call Girls Hyderabad 📱9352852248 Book Well Trand Call Girls In...🌹Attapur⬅️ Vip Call Girls Hyderabad 📱9352852248 Book Well Trand Call Girls In...
🌹Attapur⬅️ Vip Call Girls Hyderabad 📱9352852248 Book Well Trand Call Girls In...
 
Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426
Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426
Call Girls in Delhi Triveni Complex Escort Service(🔝))/WhatsApp 97111⇛47426
 
Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...
Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...
Saket * Call Girls in Delhi - Phone 9711199012 Escorts Service at 6k to 50k a...
 
Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...
Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...
Russian Call Girls Lucknow Just Call 👉👉7877925207 Top Class Call Girl Service...
 
Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...
Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...
Models Call Girls In Hyderabad 9630942363 Hyderabad Call Girl & Hyderabad Esc...
 
Call Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Rishikesh Just Call 8250077686 Top Class Call Girl Service Available
 

Evaluation and imaging for lung SBRT

  • 1. Pre SBRT workup, Imaging and Contouring Dr. Naveen Mummudi, Dr. J P Agarwal IAEA-RTC meet – May 2017
  • 4. MDT / clinical forum • Patients with stage I lung cancer are candidates for curative treatment and can be divided into three major groups: • Low-risk surgical patients - usually treated by lobectomy; • High-risk surgical patients - treated with sublobar (segmental or wedge) resection or SBRT; and • Medically inoperable patients - treated with EBRT or SBRT
  • 5. MDT / clinical forum • Inoperable • Majority • Operable • Patient preference • Clinical trial setting  Medical inoperability  Defined as “the presence of co-morbid illnesses that renders the patient at higher than acceptable risk of surgical morbidity and mortality.”  Competing risk scenario - where risk of death from medical illnesses is balanced by the risk of death from lung cancer. Colice, Shafazand et al. 2007
  • 6. Pre SBRT work up • Metastatic workup • Diagnosis – Pathological / Radiological • Imaging – CT / PET CT / MR Brain • Medical condition assessment • Pulmonary reserve • Cardiology status • Other comorbid conditions • Tumour characteristics • Location – Peripheral / central / ultra central
  • 7. Oncological assessment • Imaging • PET CT whole body / CECT Thorax • MRI brain • EUS-TBNA: ?role • 2 prospective trials evaluating PET+/- EUS-TBNA • Confirmation of diagnosis • Pathological – CT guided/trans-bronchial • Radiological – imaging characteristics
  • 9. Oncological assessment …developed a model that demonstrates that treating an SPN without pathology is justified when the likelihood of malignancy is 85% Louie 2014
  • 10. Medical assessment • Pulmonary function • GOLD – COPD • ACCP recommendations • Cardiac evaluation • Charlson comorbidity index
  • 11. Lung volumes - Spirometry
  • 12. Spirometry • Patients with advanced lung disease have decreased survival defined by the severity of their disease. • In patients with COPD, FEV 1 < 35% predicts approximately 10% mortality per year (50% 5-year survival).
  • 13. Medical evaluation • DLCO • Cardiopulmonary Exercise Testing • 6 minute walk test / Incremental shuttle walk test • Split function test • Ventilation/perfusion scinitigraphy • Cardiac evaluation • 2D ECHO
  • 14. Algorithm for cardiac assessment ERS/ESTS task force 2009
  • 17. Tumour characteristics • Size • Location of tumour • Severe toxicity rates of 17% and 46% at 3 years for peripheral and central lesions Timmerman, 2003, Chest McGarry, 2005, IJROBP Glide-Hurst, 2014, J thorac dis
  • 21.
  • 22. Immobilization • Accurately re-position patient • Reduce/Minimize patient voluntary and involuntary motion • Reduce/Minimize organ/target motion • Abdominal compression • Comfortable for long treatment • Compatible with IGRT • Not interfere with treatment beam Body Pro-Lok TM frame Body Fix Abdominal Compression Thermoplastic Long mask
  • 23. Commercial devices Abdominal compression belt • Plastic board with two long slits on the sides • Blood pressure cuff, Velcro® mounted under the board • Adjustable, Velcro® covered belt • Sewn-on ruler for consistent setup Pneumatic Compression Belt • Air inflation bulb • Pressure gauge • Non-Rigid • Marking of the patient skin & immobilization device • Recording of the pressure
  • 24. Immobilization/Simulation • Careful positioning in the immobilization device, supporting the hands and shoulders • premedication with analgesia (e.g., to prevent shoulder pain) • anxiolytic may be needed • Scanning in TX Position • CT, MR, PET-CT • CT scan with ≤ 3 mm slice thickness • Motion Management • Abdominal Compression Plate • Pressure Belt • Body Immobilization
  • 25. Respiratory motion Causes artifacts during imaging acquisitions Radiation delivery limitations Limiting treatment planning Treatment planning difficulty
  • 26. When to manage respiratory motion? AAPM Task Group 76: respiratory management techniques should be considered if either of the following conditions occur – • > 5 mm range of motion is observed in any direction • Significant normal tissue sparing can be gained using respiration management 26 The Management of Respiratory Motion in Radiation Oncology; Report of AAPM Task Group 76 July 2006 by American Association of Physicists in Medicine
  • 27. Recommended Clinical Process for patients with whom respiratory motion during RT is a concern 27
  • 28. Methods to Account for Motion • Motion-encompassing methods • Respiratory gating methods • Breath-hold methods • Forced shallow breathing with abdominal compression • Real-time tumor-tracking methods
  • 29. CT Simulation • Suppressed respiratory motion techniques • Compression Paddle, Pressure Belt • Free Breathing (FB) & Slow CT-Scanners • Free Breathing & Fast CT-Scanners • Breath-Hold (BH) CT-Scans • Respiratory Correlated CT (4D-CT)
  • 30. Motion Management Strategies Method Technique Incorporate all movements 4DCT or Slow CT Freeze movement Breath hold Intercept movement Gated Radiotherapy Track or Chase the tumor Implanted markers and specialized treatment delivery 30
  • 31. Slow CT scanning • Scanner operates at a particular couch position for longer than the respiratory cycle so that the image of the tumor would show the full extent of respiratory motion. • Yields a tumor-encompassing volume • Limitation: respiratory motion will change between imaging and treatment; • additional margins are required to account for these variations. • One CT scan is obtained • overall treatment process does not increase in complexity over that of a free-breathing CT scan • Loss of resolution due to motion blurring, which potentially leads to larger observer errors in tumor and OAR delineation. • only recommended for lung tumors that are not involved with either the mediastinum or the chest wall. • Increased dose of radiation from slow CT scanning compared with conventional CT scanning. 31
  • 32. Inhale and exhale breath-hold CT • Advantage: blurring caused by motion present during free breathing is significantly reduced during breath-hold. • But taking both inhale and exhale CT scans will increase scanning time and relies on the patient’s ability to hold breath reproducibly. • Two scans will be obtained; thus, image fusion and extra contouring are required. • Dose calculation should be performed on the CT data set that is most appropriate for the particular patient, e.g., exhale CT for patients generally spending more time at exhale than inhale. • The exhale scan will tend to underestimate the lung volumes and, hence, overestimate the percentage of lung volume receiving a specific dose. 32
  • 33. Respiratory-triggered CT scan • Slice acquisition is triggered by a respiratory signal, such that slices are only acquired in a pre-set phase of respiratory cycle. • The result is a 3D image in which all the slices are acquired in the same phase of breathing. • A scan is acquired with the imaging beam on during the entire breathing cycle and this is performed at all couch positions. Subsequently CT slices are reconstructed at consecutive points of the breathing cycle. 33 4-D CT
  • 34. Patient Training • The ability to achieve reproducible breathing or breath-hold patterns is a requirement for allowing the patient to proceed to simulation and treatment. • Prior to the start of simulation, the patient should be made familiar with the equipment and its purpose. • A physicist or trained designee should perform the coaching and evaluation, at least in the initial clinical implementation. 34
  • 35. Different ways to acquire respiratory trace • VARIAN : Real-Time Position Management System (RPM) 35 • ELEKTA : Active Breath Coordinator (ABC) • SIEMENS : ANZAI belt
  • 36. RPM system • Consists of a plastic marker block with six metallic reflectors (3 cm apart for calibrating amplitude) which is placed on patient’s abdomen between the xiphoid and umbilicus. • A infrared camera records the abdominal surface motion. • RPM software tracks the marker trajectory in real time and calculates the respiratory phase on the basis of observed amplitude. • CT scanner and RPM system communicate during data acquisition to indicate when beam is turned on or off. 36
  • 37. Marker Block RPM system can detect the motion of the marker block in vertical, lateral and longitudinal dimensions. 37
  • 38. 4DCT • 4DCT scans can be performed both in sequential and in helical scanning modes — • In sequential mode, beam is kept on during a breathing cycle at each couch position • In helical mode, beam is kept on during the entire scan, while the pitch is very low. • In both cases, this in effect provides a densely oversampled scan. 38
  • 39. 39
  • 40. 40
  • 41. 4DCT • Typically, a total of 1000 –1500 images are acquired during a 4D-CT study. Approximately 20 –25 images are reconstructed per slice, evenly distributed throughout the respiratory period. • Each reconstructed axial image represents the anatomy at a different instant during the patient’s respiratory cycle. • On the basis of the temporal correlation between the surface motion and image data acquisition, a specific respiratory phase is assigned to each image. • An axial image at a given couch position is binned on the basis of its respiratory phase. 41
  • 42. 42
  • 43. Phase vs. Amplitude sorting • Majority of the published 4D-C T techniques have used a time-based phase sorting method for retrospectively gating image data. • This is subject to misalignment due to varying inhale and exhale slopes, periods, and amplitudes in the respiration trace. • Rietzel et al. proposed an amplitude sorting method -- a constant amplitude on the respiratory curve is chosen to designate the phase position. • Although this method eliminates the possibility of misalignment, it increases the potential for missing phase sets. If a certain amplitude is not reached in all cycles of the recorded respiration trace, then that phase set cannot be created without a gap in the volume. 43 Rietzel E, Pan TS, C hen GTY. 4D CT: Image formation and clinical protocol. Med Phys. 2005;32(4):874-889
  • 44. 4DCT • 4D CT scan not only reduces motion artifacts, but also gives the tumor/organ motion information. • There may still be blurring artifacts in each slice caused by the residual motion within the slice acquisition time, but shorter the slice acquisition time, smaller the artifacts. • 4D CT scan is NOT really 4D Temporal information is mapped onto one breathing cycle. Irregular respiration will cause artifacts in 4D CT images. Breath coaching is always needed. 44
  • 45. 4DCT • 4DCT scanning procedure of the entire thorax takes about 90 s. • Radiation exposure from 4DCT acquisition is approximately six times the dose of a single conventional helical CT scan (range 0.02 - 0.09 Gy) • Generation of individualized and usually smaller target volumes derived from 4DCT scans in comparison to standard PTVs justifies this additional radiation exposure 45
  • 46. 46
  • 47. H. Hof et al. / Radiotherapy and Oncology 93 (2009) 419–423 Conventional vs. 4D based target definition PTV4D is not only smaller in most parts but also extends to areas not covered by PTVconv 47
  • 48. Using 4DCT data to draw Target • A composite target volume is the union of individual target volumes at different instants in time. • The standard approach would include contouring GTVs on all binned data sets (usually 10). • Alternatively, contour GTV on the volumes at end-inhale and end-exhale and fuse them. The composite contours from these extreme data sets are then overlaid onto each breathing phase and visually verify whether the composite volume includes all instances of GTVs at other respiratory phases. • Strategy of contouring extreme tumor positions will fail whenever the size of the tumor is smaller than its motion amplitude. 48
  • 49. 4-D CT: Generating Target Volumes 49 Different Target Volumes derived from GTV Target definition according to the recommendations in ICRU Report 62 ICRU Report 62 recommends use of an internal target volume (ITV) to account for variations in size, shape, and position of the CTV International Commission on Radiation Units and Measurements. ICRU report 62: Prescribing, recording, and reporting photon beam therapy (Supplement to ICRU report 50). Bethesda, MD: ICRU 1999
  • 50. Maximal Intensity Projection (MIP) • When a significant density difference exists between the tumor and surrounding tissue, it may be exploited to decrease the contouring workload. • A Maximal Intensity Projection (MIP) is automatically generated from the entire 4D-CT by assigning each voxel the greatest Hounsfield unit value from all corresponding voxels over the multiple respiratory phase image data. • For a lung tumor, this results in identification and localization of high- density tumor voxels compared with lower density lung tissue voxels. 50
  • 51. Failure of MIP technique 51 Rietzel et al. Maximum-intensity volumes for fast contouring of lung tumors Including respiratory motion in 4dct planning; Int. J. Radiation Oncology Biol. Phys., Vol. 71, No. 4, pp. 1245–1252, 2008 While contouring using MIP technique one needs to be careful for nodal volumes within the hilum or mediastinum, tumors located near the diaphragm, and tumors surrounded by atelectasis
  • 52. Window effect For Parenchymal disease: W=1600 L= -600 For Mediastinal disease: W=400 L=20 These correlate best with pathological tumor sizes
  • 53. Tumor and OAR Delineation • If 4DCT unavailable or unsuitable free-breathing helical images can be used for treatment planning • In selected patients intravenous CT contrast may help to identify the GTV • When PET imaging is available (either in the diagnostic or preferably, the treatment position) it is fused to the exhale CT and may be used to inform the contouring process, especially in instances where there is a neighbouring region of atelectasis Planning Target Volume (PTV) • For the remaining uncertainty a setup margin is required • A uniform expansion of 5 mm is typically applied to the 4DCT based ITV to generate the PTV • In certain circumstances, for example OAR proximity, this may be individualized
  • 55. Atlas of lung, esophagus, and spinal cord Int J Radiat Oncol Biol Phys. 2011 81(5):1442-57 Recommendation based on Timmerman et al for RTOG 0236 and RTOG 0618, Bezjak et al for RTOG 0813
  • 56. Atlases for Organs at Risk (OARs) in Thoracic Radiation Therapy • Feng-Ming (Spring) Kong MD PhD • Leslie Quint MD • Mitchell Machtay MD • Jeffrey Bradley MD
  • 57. Lungs • Both lungs should be contoured using pulmonary windows. • The right and left lungs can be contoured separately • Total lung for dosimetry • All inflated and collapsed, fibrotic and emphysematic lungs should be contoured. • Hilar region and trachea/main bronchus should not be included in this structure
  • 58. Esophagus • Begin at the level just below the cricoid to its entrance to the stomach at GE junction. • Contoured using mediastinal window/level on CT to correspond to the mucosal, submucosa, and all muscular layers out to the fatty adventitia. • Barium swallow for better delineation.
  • 59. Spinal cord • Bony limits of the spinal canal. • Start at the level just below cricoid to the bottom of L2 • base of skull for apex tumors and continuing • Neuroformanines should not be included.
  • 60. Begin below the level of post-cricoid region
  • 61. Include the entire spinal canal
  • 62. Barium swallow allows better delineation of esophagus
  • 64.
  • 65. Inferiorly till the GE junction
  • 66. Pericardium • Includes pericardial fatty tissue, part of great vessels, normal recesses, pericardial effusion (if present) and heart chambers. • Starts at one slice above the top of aortic arch, ends at the last slice of heart apex at diaphragm. • Pericardium includes the heart.
  • 67. PericardiumSVC Begin one slice above the top of aortic arch
  • 68.
  • 73.
  • 74.
  • 75.
  • 76. Great vessels • Contoured separately from the heart, using mediastinal windowing to correspond to the vascular wall and all muscular layers out to the fatty adventitia. • Start at least 3 cm above the superior extent of the PTV and up to at least 3 cm below the inferior extent of the PTV. • For right sided tumors, SVC will be contoured, and • For left sided tumors, the aorta will be contoured. • The ipsilateral PA will be delineated for tumor of either side.
  • 78. IVC
  • 79. Heart • Contoured along with the pericardial sac. • Superiorly begin at the level of the inferior aspect of the pulmonary artery passing the midline and extend inferiorly to the apex of the heart.
  • 80. Start at the level of the inferior aspect of the pulmonary artery passing the midline
  • 81.
  • 82.
  • 83. Heart and pericardium are to be overlapped
  • 84. Proximal bronchial tree • Includes the • distal 2 cm of the trachea, • the carina, • the right and left mainstem bronchi, • the right and left upper lobe bronchi, • the intermedius bronchus, • the right middle lobe bronchus, • the lingular bronchus, and • the right and left lower lobe bronchi.
  • 85.
  • 86.
  • 87.
  • 88.
  • 89. Proximal Bronchus Tree Ends at the level of lobar bronchus bifurcating into segmental bronchus
  • 90. Brachial plexus • Required for patients with tumors of upper lobes. • Only the ipsilateral brachial plexus is contoured. • Includes the spinal nerves exiting the neuroforamine from top of C5 to top of T2. • Should extend at least 3 cm above the PTV.
  • 91. Identify anterior and middle scalene muscles from C5 to insertion onto the first rib. Start at the neural foramina from C5 to T1
  • 92. Extend from the lateral aspect of the spinal canal to the small space between the anterior and middle scalene muscles.
  • 93. Contour the trunks of the brachial plexus between the anterior and middle scalene muscles.
  • 94.
  • 95. Where no neural foramen is present, contour only the space between the anterior and middle scalene muscles
  • 96. Contour the trunks of the brachial plexus between the anterior and middle scalene muscles.
  • 97. Eventually the middle scalene will end in the region of the subclavian neurovascular bundle.
  • 98. Vein, artery, and nerve (VAN, anterior to posterior) will go over the 1st rib and under the clavicle Contour the brachial plexus as the posterior aspect of the neurovascular bundle.
  • 99. IV contrast greatly facilitates contouring The first and second ribs serve as the medial limit
  • 100.
  • 101.
  • 102. Chest wall • Autosegmented from the ipsilateral lung with a 2-cm expansion in the lateral, anterior, and posterior directions. • Anteriorly and medially, it ends at the edge of the sternum. • Posteriorly and medially, it stops at the edge of the vertebral body with inclusion of the spinal nerve root exit site. • Includes intercostal muscles, nerves exclude vertebrate bodies, sternum and skin. This recommendation was based on 1. Kong et al, Int J Radiat Oncol Biol Phys. 2010 Oct 7. 2. “CW2cm consistently enabled better prediction of CW toxicity than CW3cm” in Mutter et al, Int J Radiat Oncol Biol Phys. 2011 Aug 23.

Notas do Editor

  1. Pitch = Table travel per rotation/Beam width Helical Approach – Philips approach - Combine image data at same phase from several respiratory cycles Cine approach – GE - Acquire limited thickness image data at specific phases in respiratory cycle
  2. The registration is made based on the nearest neighbor criterion, where at each slice location the image is selected so that its phase is closest to each phase bin.
  3. Even if a 4DCT scan is of a very high quality with few artifacts, the motion of a structure exhibited in a 4DCT scan is still only representative of the motion taking place in the few breathing cycles during which the patient passes through the CT-scanner. It is a movie ‘snapshot’ of the motion.
  4. Mean IP represents time-weighted location of the tumor
  5. In contrast to prior RTOG lung studies of contouring the major trunks of the brachial plexus with inclusion of subclavian and axillary vessels, this trial requests contouring the nerves according to the CT anatomy on every other CT slice.