Brochure containing descriptions and specifications of the DeLonghi Climaveneta range of commercial and domestic heat pumps and related products/technologies.
2. 2
ICS HEAT PUMP TECHNOLOGY
DeLonghi-Climaveneta
PARTNERSHIP
The ICS Group has a strong historical
relationship with DeLonghi-Climaveneta,
Europe’s leading manufacturer of
refrigeration based temperature control
equipment.
Having built their first Heat Pump units in 1979, DeLonghi-Climaveneta can certainly stake
their claim as being one of the most innovative and forward thinking manufacturers of air
source heat pumps and ground source/geothermal heat pump over the last thirty years. This
well established historical relationship between the ICS Group and DeLonghi-Climaveneta
has formed the basis for ICS Heat Pump Technology being selected by DeLonghi-Climaveneta
to exclusively provide the DeLonghi Professional range of residential heat pumps and
Climaveneta commercial heat pumps throughout the UK and Ireland.
3. 3
CONTENTS
ICS DELONGHI-CLIMAVENETA PARTNERSHIP pg 2
DELONGHI-CLIMAVENETA pg 4-5
ICS HEAT PUMP TECHNOLOGY pg 6
ICS APPROVED PARTNER PROGRAMME pg 7
RESIDENTIAL CASE STUDIES pg 8
COMMERCIAL CASE STUDIES pg 9
AIR SOURCE HEAT PUMPS INTRODUCTION pg 10-11
MEDIUM TEMPERATURE HEAT PUMPS pg 12-19
• Bran H Medium Temperature Air Source Heat Pump pg 12-13
• AWR MTD Medium Temperature Air Source Heat Pump pg 14-15
• DHW Twin Medium Temperature Air Source Heat Pump pg 16-17
• MICS-N Medium Temperature Air Source Heat Pump pg 18-19
HIGH TEMPERATURE HEAT PUMPS pg 20-27
• i-KI High Temperature Air Source Heat Pump pg 20-21
• HT 65ºC High Temperature Air Source Heat Pump pg 22-23
• i-NRG High Temperature Air Source Heat Pump pg 24-25
• Prana HT High Temperature Air Source Heat Pump pg 26-27
GROUND SOURCE & GEOTHERMAL HEAT PUMPS INTRODUCTION pg 28-29
• BWR MTD Ground Source & Geothermal Heat Pump pg 30-31
• DHW Twin Ground Source & Geothermal Heat Pump pg 32-33
• Prana MTD Ground Source & Geothermal Heat Pump pg 34-35
• Prana DHW Ground Source & Geothermal Heat Pump pg 36-37
BUFFER TANKS pg 38
DHW CYLINDERS pg 39
FAN COILS & HYDRONICS pg 40-41
APPLICATION & SPECIFICATION SUPPORT pg 42
ACCESSORIES pg 42
TECHNICAL SERVICE SUPPORT pg 43
4. 4
DeLonghi-Climaveneta
PRODUCT INNOVATION
RESEARCH & DEVELOPMENT
HEAT PUMP FOCUS
40 YEARS EXPERIENCE
DeLonghi-Climaveneta is the leading,
refrigeration manufacturer in Europe.The
company has a worldwide reputation for
product reliability and quality with over 35
years of market leading experience. The
company has 5 key manufacturing
facilities occupying some 52,000 square
meters of production space. The
company achieves a turnover level in
excess of 210 million euros worldwide.
5. 5
A COMPLETE RANGE OF HEAT
PUMPS FROM 5KW TO 400KW,
A BRAND THAT IS SYNONYMOUS
WITH RELIABILITY & QUALITY,
WITH ALL THE ADVANTAGES THAT ONLY
A LEADING MANUFACTURING CAN OFFER.
With more than 40 years of experience in air conditioning, DeLonghi-Climaveneta is truly a
leading organisation in the expanding domestic, commercial and industrial heat pump market.
1ST IN EUROPE & 5TH IN THE WORLD
The mission and values that have guided us for 40 years have enabled us to become the number one manufacturer in Europe and the
fifth in the world within the temperature control sector.
+ 90,000m² of productive area
+ 5 specialist focused manufacturing plants, 4 located in Italy
and 1 located in Shanghai China
+ Complete range of products from 1kW to 2400kW
+ Optimised heat pumps from 5kW to 400kW (modular)
+ First heat pump manufactured in 1979
+ Now 12 ranges of air source and ground source/geothermal
+ Residential and commercial equipment
Commercial Heat Pumps Residential Heat Pumps
6. 6
ICS HEAT PUMP
TECHNOLOGY
ICS Heat Pump Technology provides a complete service offering design/specification support,
supply/commissioning services and after sales support for air source heat pumps, ground source heat
pumps and geothermal heat pumps within both the commercial and residential sectors.
ICS has been providing temperature control systems and heat transfer equipment for an extensive range
of applications and users since 1988. Twenty years of experience has resulted in an extremely well
established business operating throughout the UK, Germany and Ireland employing over 200 people with
a combined group turnover of circa £30m.
PROVEN TECHNOLOGY A COMPANY YOU CAN TRUST
• An ICS group company
Massive reductions in carbon emissions can be achieved by using heat pumps
• Established over 20 years
and significant cost savings are possible by increasing the efficiency of a
property when a heat pump system is installed. • £30m turnover throughout UK and Europe
• Over 200 specialised and highly skilled
Ground source or geothermal heat pumps along with air source heat pumps employees
take low grade energy from the earth or atmosphere and convert it into high
• Excellent reputation in climate control
grade heat energy to be used within the property
services
Whether a new build project or a retrofit application, the range of heat pumps • Provides a complete service
provided by Climaveneta and DeLonghi Professional is able to provide a practical • Implements a “best advice” policy to all
and cost effective solution to heating and sanitary hot water requirements from customers
5kW to 1200kW.
7. 7
APPROVED PARTNER PROGRAMME
SUPPORT
ICS Heat Pump Technology & DeLonghi-Climaveneta
provides a specialist support service to their
HEAT PUMP
customer base, which is designed to assist the heat
pump specifier or installer in maximising the fast
developing opportunity within the renewable APPROVED PARTNER PROGRAMME
heating sector.
We understand that providing high quality equipment is only half of the package which is why the ICS Approved
Partner Programme (APP) has been developed over the past two and a half years in order to provide the specifier
or installer with the complete heat pump support service to accompany the 12 ranges of residential and commercial
heat pumps provided by DeLonghi-Climaveneta.
The ICS APP is split into 4 main elements each of which provides the specifier or installer with a range of specialist
areas to support their business.
apptraining
apptraining £££
appmarketing
appmarketing apptechnical
apptechnical appinfocentre
appinfocentre
• LOGIC ACCREDITED APP • PARTNER BRANDED WEBSITE APP • TECHNICAL SUPPORT DESK APP • CPD APP
• PRODUCT DAY APP • SALES/PRODUCT SUPPORT LITERATURE APP • FIELD BASED TECHNICAL SUPPORT APP • INDUSTRY NEWS APP
• IN COMPANY SALES & TECHNICAL APP • ICS-DELONGHI NATIONAL MARKETING APP • FACTORY SUPPORT APP • MSC APP
• FIELD SUPPORT APP • DIRECT MARKETING/EXHIBITION • INSTALLER/SPECIFIER INTERNET BASED • LEGISLATION APP
SUPPORT APP PARTNER HUB APP
Commercial Heat Pumps Residential Heat Pumps
8. 8
CASE STUDIES
RESIDENTIAL CASE STUDY NEW BUILD WITH SUBSTANTIAL REFURBISHMENT
Property: 5 bedroom 400sq/m high specification low energy house
Application: New build with substantial refurbishment
Locations: North West Coast
Accreditations: MSC Accredited equipment used
Installation: ICS Heat Pump Technology Approved Partner
Equipment: 1 x DeLonghi Professional i-NRG 16.3kW Inverter
Air Source Heat Pump
1 x 200L Buffer Tank
1 x 300L Optimised unvented cylinder
1 x 35L Inertia tank
5 x Climaveneta i-life fan coil terminals
4 x DeLonghi-Climaveneta system/room controllers
RESIDENTIAL CASE STUDY BBC DIY SOS LOW COST HOUSING
Property: Affordable Housing
Application: Refurbishment & New Build
Locations: Wales
Accreditations: MSC Accredited equipment used
Installation: ICS Heat Pump Technology Approved Partner
Equipment: 1 x De-Longhi Climaveneta BRAN H 0011 Air
Source Heat Pump
1 x Tank In Tank DHW Cylinder
1 x Installation Kit
RESIDENTIAL CASE STUDY LARGE NEW BUILD
Property: 5 Bedroom Country House
Application: New Build
Locations: Midlands
Accreditations: MSC Accredited equipment used
Installation: ICS Heat Pump Technology Approved Partner
Equipment: 1 x De-Longhi Climaveneta Z1T17 Cube Ground
Source Heat Pump
800m PEX-A Pipework in Horizontal Straight
Formation
1 x 300L Twin Coil Heat Pump Cylinder
1 x 100L Buffer Tank
9. 9
COMMERCIAL CASE STUDY NEW BUILD SCHOOL
Property: School
Application: New Build School 90kW
Location: Rural Lancashire Town
Installer: North West based - ICS Approved Partner
Installer
Equipment: 1 x BWR DHW 0101 1 x BWR MTD 0101,
2 x 400L Buffer Tank
COMMERCIAL CASE STUDY SUPERSTORE HEATING PROJECT
Property: Superstore
Application: Space heating - Mono-valent system 360kW
Locations: Scotland
Accreditations: MSC Accredited equipment used
Installation: ICS Heat Pump Technology Approved Partner
Equipment: ICS-Climaveneta 8 x MICS N 0182 Air Source
Heat Pumps & 2 x Buffer Tanks
COMMERCIAL CASE STUDY AMBULANCE STATION RETROFIT
Property: NHS Ambulance Station
Application: Retrofit ‘Off Gas’ Boiler Replacement 20kW
Locations: South West England
Equipment: 1 x 20kW high temperature 65ºC
Climaveneta AW HT Air Source Heat Pump
Emitter: Radiators
COMMERCIAL CASE STUDY SPACE HEATING & COOLING
Property: Office & Warehousing
Application: Refurbishment 120kW
Locations: North West England
Accreditations: MSC Accredited equipment used
Installation: ICS Heat Pump Technology Approved Partner
Equipment: 2 x De-Longhi Climaveneta DHW Air Source
Heat Pumps
1 x De-Longhi Climaveneta MICS-N Air Source
Heat Pump
2 x ICS HTP Buffer Tanks
Various DeLonghi Climaveneta Fan Coils
Various DeLonghi Climaveneta Air Handling
Units
Commercial Heat Pumps Residential Heat Pumps
10. 10
AIR SOURCE
MEDIUM & HIGH
TEMPERATURE HEAT PUMPS
MEDIUM TEMPERATURE AIR SOURCE HEAT PUMPS
Unit & Hot Heating Simultaneous Cooling Simultaneous Heat Reduced Lower Modular
Capacity Water Heating/ (Optional) Cooling, Recovery Carbon Heating
Hot Water Hot Water/ Emissions Costs
Heating
BRAN H
6-14kW HOT WATER HEATING
pg 12-13
Residential
AWR MTD XE
6-25kW
pg 14-15 HOT WATER HEATING COOLING
Residential &
Commercial
DHW Twin
20-33kW HOT WATER HEATING HEATING
HEATING +
COOLING COOLING
COOLING +
HOT WATER HOT WATER
pg 16-17
Commercial
MICS N
20-50kW
HEATING COOLING MODULAR
pg 18-19
Commercial
11. 11
Our air source heat pumps provide a very efficient means of utilising renewable energy
whilst being very straightforward in their installation.
The DeLonghi-Climaveneta range of air source heat pumps provides units with
capacities from 5kW to 200kW which are suitable for a wide range of applications.
Single phase 240v powered air source heat pump units are available up to a capacity
of 14kW and three phase 415v units complete the range for larger residential heat
pump and commercial applications.
Modular capability allows for the multiple connection of up to six units operating as
one single package, hence large capacity projects can be specified by utilising this AIR SOURCE HEAT PUMPS
modular configuration approach. The single controller ensures that running hours are Heat energy is collected from the external ambient air
equalised & maintained across the various heat pumps whilst also ensuring that the using the heat pumps integral evaporator coil. This energy
is then transferred as high grade heat into the building.
system operates with maximum modular part load efficiency at all times.
HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION
HIGH TEMPERATURE AIR SOURCE HEAT PUMPS
Unit & Hot Heating Simultaneous Cooling Simultaneous Heat Reduced Lower Modular
Capacity Water Heating/ (Optional) Cooling, Recovery Carbon Heating
Hot Water Hot Water/ Emissions Costs
Heating
i-KI
9.5kW HOT WATER HEATING MODULAR
pg 20-21
Residential
HT 65ºC
10-27kW
pg 22-23 HOT WATER HEATING MODULAR
Residential &
Commercial
i-NRG
16.3kW HOT WATER HEATING HEATING
HEATING +
COOLING COOLING
COOLING +
MODULAR
HOT WATER HOT WATER
pg 24-25
Residential
PRANA HT
40-100kW
HOT WATER HEATING COOLING MODULAR
pg 26-27
Commercial
Commercial Heat Pumps Residential Heat Pumps
12. 12
Bran H
Unit Description HEATING HOT WATER
The DeLonghi Prana Bran H range of air source heat pumps provide a high
level of performance along with a high level of specification but in a very
cost effective package.
• The nominal refrigeration COP* (efficiency) of these units is high
averaging over 4.0 but importantly the performance of these units
when operating in lower ambient temperatures is also at a high
level. Designed to operate in ambient temperatures as low as -15ºC
the Bran H range is more than capable of operating in UK & Irish
winter temperatures.
• These units incorporate a built in heating system circulation pump,
control for hot water production including Y Plan valve (optional, not
supplied as standard) operation along with full weather compensation
and controls which give a very short defrost cycle in lower ambient
temperatures.
• The Bran H range will operate with a standard 2 channel time clock or
programmable room stat, please contact technical support for
clarification or specification details.
• The Bran H range will function with any heat pump optimised DHW
cylinder allowing flexibility in terms of stored water volume to match
the demands of each particular project.
Unit Summary
• This advanced control means that these units are able to operate with
BRAN H UNITS: AW very low system volumes, a minimum open circuit volume of 3.5 litres
CAPACITY: 6kW-14kW per nominal kW of heat pump capacity is required which can reduce
installation costs considerably. A buffer tank is recommended to
POWER SUPPLY: Single Phase models achieve maximum operational efficiency in order to provide thermal
mass and efficient defrost capability.
A cost effective high specification air source solution providing
heating and hot water up to 55ºC output temperature (50ºC at • These DeLonghi-Climaveneta units are high specification heat pumps
-3ºC ambient) which are built to exacting standards with regard to efficiency and
functionality. All the units are European manufactured and benefit from
HIGH EFFICIENCY & PERFORMANCE: COP 4.01 (401% efficient) the DeLonghi-Climaveneta approach to product development and
quality management providing the complete package that would be
*Average coefficient of performance (COP) for the Bran H range based on an ambient
temperature of 7ºC and 35ºC flow temperature
expected from a premier manufacturer.
COP 3.6 (360% efficient @ 2ºC ambient & 35ºC flow temp)
NOTE. Actual system efficiency (COP) and annual performance will depend on the
distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed
in order to provide efficient operational performance. AXIAL
FEATURES & OPERATIONAL BENEFITS: *(COP is shown without circulation pump input power. Please note that unlike most other heat
• MSC accredited heat pumps, certificate HP0005 pumps these units incorporate built in circulation pumps, therefore by not including the circulation
pump input power we are able to provide a direct performance comparison with other units).
• Cost effective
• High efficiency
• Full DHW and heating control
• Built in circulation pump • Microgeneration scheme accreditation allows
• High COP access to grant funding and also guarantees
performance and manufacturing quality.
• Full floating control for high efficiency & minimum defrost
Certificate Number MSC HP0005
time to -15°C ambients Heat Pumps
13. 13
Bran H Air Source Medium Temperature Heat Pumps
Main Components
• Condensate drain pan kit. • The electronic controller menu allows management of:
• Condensing coil protection grills - circulation pump on the system side
- domestic hot water production via control of the external three-way
• Housing and base are made from hot-galvanized epoxy powder coated
valve (not supplied)
sheet metal
- 24 hour timer operation for a cylinder heater
• High efficiency and low pressure drop stainless steel (AISI 316) water - control of the incorporated supplementary heating element
exchangers, with anti-freeze heating element and differential pressure - outdoor temperature sensor for modulating set point weather
switch compensation
• Hermetic scroll type compressors, equipped with the crankcase heater • Soft start for 230V/1/50Hz units (45 amps & 25 amps for the 0011
and thermal protection model)
• Condensers finned tubes with copper and aluminium fins high exchange • Phase sequence control relay
surface (100% fully quality tested); sub cooling circuit to prevent freezing
• The water circuit comes complete with:
at the base.
- variable flow circulation pump for all models
• Axial electric fans, external rotor, electric motor with a 6-pole fitted with - differential pressure switch on plant side
thermal protection, housed in an aerodynamic profile with safety grill - expansion vessel (Heat Pump circuit only)
• Low external air temperature device: - safety valve
- fan speed regulation with pressure switch which maximises - manual filling assembly- pressure gauge- manual air vent valve
efficiency at part load NB: Optional equipment includes a range of tanks & cylinders plus
• Electrical modulating frost protection heating within the base which standard installation packs, see current price list or contact ICS HPT or your
minimizes the risk of condensate freezing during periods of low ambient distributor for details.
temperature
Bran H 0011M 0025M 0041M
Heating capacity (1) kW 6.5 8.7 13.8
Effective input power according to EN 14511 (1) kW 1.82 2.31 3.68
Heating capacity (2) kW 6.5 8.7 13.8
Power absorbed (2) kW 1.65 2.15 3.40
COP* (2) 3.94 4.05 4.06
Rated water flow (1) m3/h 1.12 1.50 2.37
Residual head (1) kPa 41 48 89
Fans n0 1 1 2
Air flow m3/s 0.9 1 1.9
Type of compressor Scroll
No. of compressors n0 1 1 1
No. of circuits n0 1 1 1
Refrigerant R410A kg 1.75 3 3
Oil Mobil EAL ARTIC 22cc kg 1.1 1.24 1.95
Pump type circulator
No. of pumps n0 1 1 1
Functioning weight kg 95 115 140
Hydraulic connections inches 3/4 3/4 1 1/4
Sound pressure level according to EN ISO 3744 dB(A) 72 73 73
Sound pressure (3) db(A) 58 59 59
Electric power supply V/ph/Hz 230-510
Common Data 0011 0025 0041
Circulation pump Included
DHW control Included
Height/Length/Width mm 640/900/370 940/900/370 1240/900/370
Weight kg 105 130 160
L
Note:
1. Heat pump mode: external air temperature 7°C DB/6°C WB, water in flow at 30°C and outlet at 35°C H
2. The total input is given by the compressor input and fans power input
3. Free field sound pressure on a reflecting surface (directivity fact. Q=2), at a distance of 1 meters H
from the external surface of the unit. Average value calculated from the sound power
W
L W
ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
details at point of quotation and/or order. Residential Heat Pumps
14. 14
AWR MTD XE
Unit Description HEATING COOLING HOT WATER
The DeLonghi Prana AWR MTD XE range of air source heat pumps provide
an extremely high level of performance and a high level of specification.
The nominal refrigeration COP* (efficiency) of these units is very high
averaging over 4.17 and importantly the performance of these units
when operating in lower ambient temperatures is also at a very high
level. Designed to operate in ambient temperatures as low as -15ºC the
AWR MTD XE range is more than capable of operating with high efficiency
in UK & Irish winter temperatures.
• These units incorporate a built in heating system circulation pump,
control for hot water production including Y Plan valve (optional, not
supplied as standard) operation along with full weather compensation
and sophisticated controls which give a very short defrost cycle in lower
ambient temperatures.
• The AWR MTD range will operate with a standard 2 channel time clock
or programmable room stat, please contact technical support for
clarification or specification details.
• A modulating source fan controls efficiency and maximises the
performance on part loads by drawing the correct amount of air
through the unit to match the load requirement of the property at any
time, so reduces running costs and also allows the units to function
with any Heat Pump optimised thermal store or cylinder.
Unit Summary • This advanced control means that these units are able to operate with
very low system volumes, a minimum open circuit volume of 3.5 litres
MTD UNITS: AWR MTD XE per nominal kW of Heat Pump capacity is required which can reduce
CAPACITY: 6kW-25kW installation costs considerably. A buffer tank is recommended to
achieve maximum operational efficiency in order to provide thermal
POWER SUPPLY: Single Phase & Three Phase models mass and efficient defrost capability.
These units can provide heating or cooling and hot water up to
55ºC, the efficient unit design incorporating supplementary • In addition to these features these units also have a built in
heating enables the AWR MTD XE to operate efficiently in low supplementary heater which provides additional capacity in ambient
ambient conditions to -15ºC. temperatures below -5ºC.
HIGH EFFICIENCY & PERFORMANCE: COP 4.17 (417% efficient) • These units also provide reversible operation, this means they can
*Average coefficient of performance (COP) for the AWR MTD XE range based on an provide cooling whilst being able to prioritise hot water production,
ambient temperature of 7ºC and 35ºC flow temperature. this means that when connected via a fan coil distribution system these
NOTE. Actual system efficiency (COP) and annual performance will depend on the
AWR MTD units can provide a complete residential or light commercial
distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed climate control option.
in order to provide efficient operational performance.
• These DeLonghi-Climaveneta units are high specification heat pumps
FEATURES & OPERATIONAL BENEFITS: which are built to exacting standards with regard to efficiency and
• MSC accredited heat pumps (AWR MTD XE accreditation pending) functionality. All the units are European manufactured and benefit from
the DeLonghi-Climaveneta approach to product development and
• Full DHW and heating control
quality management providing the complete package that would be
• Reversible operation can provide cooling for A/C applications expected from a premier manufacturer.
• Built in circulation pump
• 55ºC output temperature (50ºC at -5ºC ambient)
• High efficiency modulating source fan(s) and circulation pump AXIAL
• Minimum defrost time operating to -15ºC ambients
• Supplementary Electric Heating Included for -5ºC ambient *(COP is shown without circulation pump input power. Please note that unlike most other heat
operation pumps these units incorporate built in circulation pumps, therefore by not including the circulation
pump input power we are able to provide a direct performance comparison with other units).
15. 15
MTD XE Air Source Medium Temperature Heat Pumps
Main Components
• Condensate drain pan kit. • Soft start for 230V/1/50Hz units (45 amps)
• Condensing coil protection grills • Reversible operation allows the production of chilled water for an
• Housing and base are made from hot-galvanized epoxy powder coated sheet air-conditioning circuit
metal • The electronic controller menu allows management of:
• High efficiency and low pressure drop stainless steel (AISI 316) water - circulation pump on the system side
exchangers, with anti-freeze heating element and differential pressure switch - domestic hot water production via control of the external three-way valve
• Hermetic scroll type compressors, equipped with the crankcase heater and (not supplied)
thermal protection - 24 hour timer operation for a cylinder heater
• Condensers finned tubes with copper and aluminium fins high exchange - control of the incorporated supplementary heating element
surface (100% fully quality tested); sub cooling circuit to prevent freezing at - outdoor temperature sensor for modulating set point weather
the base. compensation
• Axial electric fans, external rotor, electric motor with a 6-pole fitted with • Phase sequence control relay
thermal protection, housed in an aerodynamic profile with safety grill • The water circuit comes complete with:
• Low external air temperature device: - variable flow circulation pump for all models
- fan speed regulation with pressure switch which maximises efficiency at - differential pressure switch on plant side
part load - expansion vessel (Heat Pump circuit only)
• Electrical modulating frost protection heating within the base which minimises - safety valve
the risk of condensate freezing during periods of low ambient temperature - manual filling assembly- pressure gauge- manual air vent valve
NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.
AWR-MTD XE 0011MS 0025MS 0031MS 0041MS 0031T 0041T 0051T 0061T 0091T
Nominal heating power (1) kW 6.30 7.40 11.2 14 10.9 14 15.9 17.9 25.10
Total absorbed power (2) kW 1.50 1.80 2.60 3.30 2.60 3.30 3.80 4.20 6
COP 4.13 4.15 4.22 4.16 4.15 4.15 4.11 4.25 4.19
Cooling capacity (3) kW 7.20 8.30 12.3 15.7 11.7 15.8 17.7 20.2 29.2
Total absorbed power (2) kW 1.90 2.20 3.30 4.10 3.10 4.20 4.70 5.30 7.80
EER Eurovent * 3.79 3.77 3.73 3.83 3.77 3.76 3.77 3.81 3.74
EER 3.82 3.82 3.81 3.84 3.84 3.81 3.81 3.81 3.85
Heating capacity (4) kW 6.10 7.30 10.8 13.6 10.6 13.8 15.4 17.5 24.60
Total absorbed power (2) kW 1.90 2.30 3.30 4.10 3.20 4.30 4.60 5.20 7.40
Cooling capacity (5) kW 5.20 6.30 9.20 11.7 8.60 11.9 13.2 15.2 22.10
Total absorbed power (2) kW 1.70 2.20 3.10 4.00 3.00 4.00 4.60 5.00 7.20
EER Eurovent * 3.06 2.86 2.97 2.93 2.87 2.98 2.87 3.04 3.07
ESEER 3.62 3.63 3.52 3.46 3.42 3.65 3.24 3.55 3.57
Compressor type SCROLL
N. Compressors N. 1
Refrigerant R410A
N. fans N. 1 1 2 2 2 2 2 2 3
Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci
Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50
Start-up current A 27 30 45 45 48 64 64 75 111
Sound power (7) dB(A) 69 69 71 71 71 71 71 72 74
Sound pressure (8) dB(A) 54 54 56 56 56 56 56 57 58
L mm 900 900 900 900 900 900 900 1550 1550
H mm 1240 1240 1240 1390 1240 1390 1390 1200 1700
W mm 420 420 420 420 420 420 420 450 450
Operational weight kg 145 150 155 170 155 170 180 250 335
L
Note:
1. Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.
2. Total input is obtained from compressor input and fan input
3. Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s.
4. Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u. H
5. Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s.
6. Ci=Circulator; Ce=Centrifugal H
7. Sound power level according to ISO 9614 and Eurovent 8/1
8. Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.
* According to the Eurovent standard without circulation pump input power. W
L W
ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right
to change update or alter the specification & details of any item shown with or without prior notice for whatever
reason. The information provided within the product guide and/or data sheets is intended for guidance purposes
only, please confirm actual current specification and equipment details at point of quotation and/or order.
Commercial Heat Pumps Residential Heat Pumps
16. 16
DHW Twin
Unit Description
HEATING + COOLING +
HEATING
HEATING COOLING
COOLING HOT WATER HOT WATER HOT WATER
The DeLonghi Prana AWR DHW are a unique range of commercial air
source heat pumps which are capable of providing a high efficiency
combination of output conditions:
• Heating only
• Simultaneous heating and hot water to 55ºC**
• Hot water only
• Cooling only
• Simultaneous cooling and hot water with up to 100% heat recovery***
• Simultaneous cooling and heating with up to 100% heat recovery***
These units can be specified to suit a particular application and due to
their ability in being able to provide two simultaneous outputs they are
able to provide real benefits on both large residential and commercial
applications.
Within the commercial sector the AWR DHW range provides flexibility and
real environmental benefits. These Heat Pumps will provide up to 100%
heat recovery which then benefits the user with free heating or hot water.
A growing demand for energy and heat recovery has created a highly
efficient requirement to use these units to recover waste energy from
waste water or fluid flows, recovering energy from cooling towers or
waste water flows is easily achievable when utilising these units in heat
recovery specification.
Also these heat pump units will provide up to 100% duty on either
primary or secondary heat exchangers along with the ability to provide
a combination of heating and hot water simultaneously or heating and
cooling simultaneously with up to 100% heat recovery. This allows these
heat pump units to provide this simultaneous output feature to manage
seasonal heating and cooling loads from the same heat pump unit***.
Unit Summary These DeLonghi-Climaveneta units are high specification heat pumps
which are built to exacting standards with regard to efficiency and
DHW TWIN UNITS: AWR functionality. All the units are European manufactured and benefit from
the DeLonghi-Climaveneta approach to product development and quality
CAPACITY: 20kW-33kW management providing the complete package that would be expected
POWER SUPPLY: Single Phase & Three Phase models from a premier manufacturer.
These units provide simultaneous supplies of domestic hot r HFC r HFC
water and heating/air conditioning. AXIAL
R-410A
AXIAL
R-410A
HIGH EFFICIENCY & PERFORMANCE: COP 3.87 (387% efficient) *(COP is shown without circulation pump input power. Please note that unlike most other heat
pumps these units incorporate built in circulation pumps, therefore by not including the circulation
*Average coefficient of performance (COP) for the AWR DHW range based on an pump input power we are able to provide a direct performance comparison with other units).
ambient temperature of 7ºC and 35ºC flow temperature
**A higher temperature DHW output is available when the unit is operating in heating mode.
NOTE. Actual system efficiency (COP) and annual performance will depend on the The actual available capacity of DHW is dependent on the heating output being provided at any
distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed time. The available part load DHW capacity will vary dependant on the part load capacity
in order to provide efficient operational performance. available in-line with the above.
FEATURES & OPERATIONAL BENEFITS: ***The AWR DHW range of units are designed to provide simultaneous heating/DHW and cooling
when operating in ambient temperatures above 10ºC unless a year round cooling load is
• MSC accredited heat pumps, certificate HP0005 available. Please contact ICS Heat Pump Technology Technical Support to confirm the suitability
of this range of equipment for each application.
• Fully self-contained unit – no external refrigerant pipes
• Standard pipe work installation to suit a plumber or heating
engineer
• Highly efficient and flexible design with easy to use controls
• Microgeneration scheme accreditation allows
• Heating, cooling and domestic hot water provided access to grant funding and also guarantees
• Suitable for large capacity hot water users and simultaneous performance and manufacturing quality.
heating & air conditioning applications Certificate Number MSC HP0005
Heat Pumps
Commercial Heat Pumps
17. 17
DHW Twin Air Source Medium Temperature Heat Pumps
Main Components
• Housing and base are made from hot-galvanized epoxy powder coated sheet metal • Secondary stainless steel plate heat exchanger providing an output kW capacity
• Hermetic scroll type compressors, equipped with the crankcase heater and up to 100% of the heat pump duty with high efficiency and low pressure drop
thermal protection provides the supply of both hot or cold water for the application with or without
any hot water or heating production on the primary heat exchanger.
• Condensers finned tubes with copper and aluminium fins high exchange surface
(100% fully quality tested); sub cooling circuit to prevent the icing at the base • The water circuit comes complete with:
- primary circuit water pump for domestic hot water or heating circuit
• Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal
protection, housed in aerodynamic profile with safety grill. - secondary circuit plant side water pump for heating or cooling circuit
- differential pressure switch on plant side
- continuous fan speed regulation with pressure switch for modulating load
management - expansion vessel Heat Pump circuit only
- safety valve (6 bar)
• Primary stainless steel (AISI 316) plate heat exchanger with high efficiency and
- manual filling assembly
low pressure drop (providing domestic hot water or heating) positioned directly
- Pressure gauge
after the compressor which gives an efficient high temperature output providing
an output kW capacity up to 100% of the Heat Pump duty. - venting and draining valve
• When combined with the secondary heat exchanger (cooling duty) these units • Soft start for 230V/1/50Hz units AWR DHW/S
will provide either full or partial heat recovery which is constantly optimised NB: Optional equipment includes a range of tanks & cylinders plus standard
via the advanced logic adjusting controller. installation packs, see current price list or contact ICS HPT or your distributor for details.
Prioritised hot water production in simultaneous DHW & heating mode Partial or 100% heat recovery available in simultaneous cooling & heating mode
HEATING + DOMESTIC HOT WATER** HEATING + AIR CONDITIONING***
AWR DHW 0065SL 0101SL
Heating capacity (A7/W35) (1) kW 21.3 33.5
Total power input (compressors & fans) kW 5.6 8.5
COP* 3.80 3.94
Recovery heating capacity (A7/W50) (2) kW 18.1 31.9
Power input kW 7.7 12.3
COP* 2.35 2.59
Cooling Capacity (A35/W18) (3) kW 21.1 33.0
Total power input (compressors & fans) kW 5.8 9.4
EER* 3.64 3.51
Cooling Capacity (A35/W7) (4) kW 17.0 27.7
Total power input (compressors & fans) kW 5.9 9.5
EER* 2.88 2.92
Type of compressor scroll
N.° of compressors n° 1
Refrigerant R407C
Plant side pump type centrifugal
DHW side pump type circulator
Power supply V/Ph/Hz 400V-3N~ 50Hz
Starting current A 127 101
Sound pressure (5) dB(A) 66 62
Height/Length/Width mm 1200/1700/650 1700/1700/650
Net weight kg 295 378
L
Note:
1. Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 30°C and outlet at 35°C
2. Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 45°C and outlet at 50°C
3. Cooling mode: external air temperature 35°C b.s., inlet water at 23°C and outlet at 18°C
4. Cooling mode: external air temperature 35°C b.s., inlet water at 12°C and outlet at 7°C H
5. Sound pressure at 1 meter distance from the external surface of the unit, free field.
* According to the Eurovent standard without circulation pump input power.
ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment W
details at point of quotation and/or order.
18. 18
MICS-N
Unit Description HEATING COOLING MODULAR
SUITABLE FOR
SWIMMING POOLS
The Climaveneta MICS-N commercial heat pump range provides a fully
optimised Air Source Heat Pump installation with the capability to provide
a modular package in excess of 200kW in capacity which operates as a
single unit. This provides a very high specification air source installation
for both large residential and commercial applications.
• A high COP is achieved at nominal conditions with a high performance
and specification designed for medium temperature heating only.
• These units have twin compressors for maximum efficiency when
operating on partial load duty. They also have the ability to operate
with four heat pumps acting as a single unit i.e. three slaves and one
master where the lead unit will interface with a BMS system or
equivalent.
• These units are reversible and provide heating or cooling to match the
demands of the project.
• Each MICS-N single unit incorporates a twin compressor design which
provides a highly efficient output when operating under part load
conditions i.e. in modular multi unit/multi compressor configuration.
***modular capability
• Circulation pumps are incorporated within the unit to give a complete
installed solution with a high specification and highly efficient system.
Unit Summary The full floating control and modulating performance of the system
provides a highly intelligent control function to give maximum
MICS-N UNITS: AWR performance and efficiency.
CAPACITY: 20kW-50kW (modular parallel systems)
POWER SUPPLY: Three Phase models • The units also incorporate a vertical air discharge system which allows
for compact positioning of single or multiple units to fit into restricted
These units provide medium to large capacity installations with a high locations.
efficiency modular system which can provide heating and air
conditioning from 20kW to 1000kW (modular). • These DeLonghi-Climaveneta units are high specification heat pumps
which are built to exacting standards with regard to efficiency and
HIGH EFFICIENCY & PERFORMANCE: COP 3.85 (385% efficient) functionality. All the units are European manufactured and benefit from
*Average coefficient of performance (COP) for the MICS-N range based on an ambient the DeLonghi-Climaveneta approach to product development and
temperature of 7ºC and 35ºC flow temperature. quality management providing the complete package that would be
COP 3.77 (377% efficient @ 2ºC ambient & 35ºC flow temp) expected from a premier manufacturer.
NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter
system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient NB: Optional equipment includes a range of tanks & cylinders plus
operational performance. standard installation packs, see current price list or contact ICS HPT or your
FEATURES & OPERATIONAL BENEFITS: distributor for details.
• MSC accredited heat pumps, certificate HP0005
r HFC r HFC
• Provides heating & cooling with a number of control options AXIAL
R-410A
AXIAL
R-410A
• Full BMS compatability with single control function for multiple units
*(COP is shown without circulation pump input power. Please note that unlike most other heat
• Modular system which provides flexibility and ease of installation pumps these units incorporate built in circulation pumps, therefore by not including the circulation
• Vertical discharge fan with compact footprint for ease of positioning pump input power we are able to provide a direct performance comparison with other units).
• Very efficient twin compressor design provides high part load
efficiency when providing heating and cooling on an annual basis
• Fully self-contained unit – no external refrigerant pipes
• Water based system which allows the heating and A/C installation to • Microgeneration scheme accreditation allows
be carried out by a mechanical contractor Access to grant funding and also guarantees
Performance and manufacturing quality.
• Highly efficient and flexible design which can be specified as a
Certificate Number MSC HP0005
package with fan coils/internal air handlers Heat Pumps