Anúncio

Soil plant testing machine

2 de Aug de 2016
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Anúncio
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Anúncio
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Anúncio
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Soil plant testing machine
Anúncio
Soil plant testing machine
Próximos SlideShares
Stability test chambersStability test chambers
Carregando em ... 3
1 de 20
Anúncio

Mais conteúdo relacionado

Apresentações para você(20)

Similar a Soil plant testing machine(20)

Anúncio

Soil plant testing machine

  1. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com Content 1. Intelligent Artificial Climate Incubator Series.............................................................................2 2. -80°C &-86°C Chest Freezer........................................................................................................ 4 3. Plant Photosynthesis Meter........................................................................................................6 4. GC-7960 Gas Chromatograph..................................................................................................... 7 5. Intelligent Leaf Area Meter.......................................................................................................10 Model: LA-YMJ-C...............................................................................................................................10 6. -25°C Laboratory Freezer (Upright)...........................................................................................12 7. Portable core drill kits...............................................................................................................15 8. LB series 0.1mg Analytical Balance...........................................................................................16 9. Portable pH/mV Meter............................................................................................................. 18 10. LA-DHG Electrothermal thermostatic blast drying oven......................................................19
  2. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 1. Intelligent Artificial Climate Incubator Series Model: LA-RTOP-B/D series Characteristics: 1. Aluminum alloy frame, delicate appearance, user-friendly. 2. Automatic microcomputer control; touch key, 3. Can set time, temperature, humidity, illuminance. 4. Can display experiment cycle, set time actual temperature and humidity (automatic humidifying and dehumidifying),set temperature, remaining time, actual temperature and illuminance level. With periodic transformation function 5. Has overheating and sensor Abnormal protection function. Ensure the instrument and same secure. 6. Full spectrum plant growth lamp, helpful for plants growth and improve the disease resistance 7. Has power failure memory, power failure time automatic compensation function; power on after power cut, can continue the original work state Intelligent Artificial Climate Incubator Series Technical parameters: Temperature range: 0-50°C Temperature fluctuation: ±0.5 Temperature uniformity: ±1°C Humidity range: 50-95% Humidity fluctuation: ±5%RH Deviation: ±5%RH Temperature, humidity, light can be programmed to periods: Type B can be divided into day (period 01) and night(period 02) Type D can be divides into 1-30 periods (include all functions of type B) Light grade: 0-3 grade (strong light: 0-8 grade) Light intensity: 0-5500LUX (normal) (Type 1: 0-12000LUX) Type 2:0- 22000LUX)
  3. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com Heating power: 500W (RTOP-1000: 1000W) Compressor power: 190W-320W Compressor delay guard time: 3min Noise: <70Db Humidifier water tank capacity: 5L Working mode: continuous operation (compressor intermittent working) Working environment: temperature 0-40°C, humidity<80%RH Non-corrosiveness gas Power: 220±22V, 50±0.5HZ Intelligent Artificial Climate Incubator Series Model difference Model Volume Size(mm) Period control mode Illuminance(LUX) LA-RTOP-150B 150L 520*550*41600 Day period and night period, automatic 1-30 periods automatic. 0-3000-5500 can choose 3000LUX for seed germinating: can choose 5500LUX for seedling germinating. illuminance of incubators can be increased by user requirement. LA-RTOP-150D LA-RTOP-260B 270L 590*590*1655 LA-RTOP-260D 590*590*1655 LA-RTOP-268B 268L 590*590*1655 LA-RTOP-268D 590*590*1655 LA-RTOP-280B 280L 590*590*1695 LA-RTOP-280D 590*590*1695 LA-RTOP-300B 300L 590*590*1785 LA-RTOP-300D 590*590*1785 LA-RTOP-310B 310L 590*590*1785 LA-RTOP-310D 590*590*1785 LA-RTOP-380B 380L 660*660*1770 LA-RTOP-380D LA-RTOP-430B 430L 660*660*1890 LA-RTOP-430D 660*660*1890 LA-RTOP-500B 500L 692*692*2000 LA-RTOP-500D 692*692*2000 LA-RTOP-800B 800L 1265*650*1850 LA-RTOP-800D 1265*650*1850 LA-RTOP-1000B 1000L 1260*660*1985 LA-RTOP-1000D
  4. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 2. -80°C &-86°C Chest Freezer Order No.:LA-HV-N80 Precise temperature control system  The worldwide famous high-accuracy computer-controlled temperature system with original binding can maintain the temperature constancy in the box at -80°C precisely. The temperature set-value can be adjusted at -10°C~-80°C, and the temperature display precision is 1°C, the resolution is 1°C and the adjusting increment is 1°C. The value is to be displayed through three-digital high-brightness figure.  The system has special high-resolution temperature calibrating function. The calibrating increment is 1°C. 24-hours tracing, recording and printing system (Optional)  The imported temperature recording and printing system. There are four precise temperature sensors (two sensors for some systems) inside the box and two temperature indicators outside the box, which are to display the temperature of upper and lower point, for users to supervise the temperature at each operating states in the box. The display precision--resolution is 1°C.  The distinguished power-off memory function can hold and store huge temperature data and information permanently.  The temperature printing has password protection function, which can prevent illegally printing of the temperature fluctuation information.  5-ways alarm system: including 2 sound alarm devices with 220V power supply, 2 light alarm devices with 220V power supply and one remote signal alarm apparatus (optional), consisting the super complementary supervision system.  The data management software is available for one or more temperature signals changes  Communicate with PC through RS-232 interface to examine the temperature curve diagnosis diagram of one or more refrigerators and display the data sheet. The data and images can be stored, inquired and printed (Optional).
  5. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com Safe control system  Keyboard lock, password protection function, and method against missing-adjustment of the operating parameter;  Setting of the alarm temperature range  7 system failure alarms (high temperature alarm, low temperature alarm, sensors failure alarm, door-opening alarm, electricity failure alarm, low back-up battery alarm, low voltage alarm).  Code display of the failure position (some machines have all these seven alarms)  Three alarm ways (buzzer alarm, flashing alarm, remote signal alarm)  The starting delay function due to self-checking and the interval protection function between temporary stop and start can ensure the reliable operation  The system can record the condition of the maximum and the minimum temperature inside the box automatically without recording paper.  With the specially designed function, the system can operate under the state of sensor failure or the state of numerical disturbance safely and automatically.  The operating parameter display function can ensure that the system is under supervision by operator and with security and stability.  Equipped with remote alarm interface  The distinguished operating parameter of the temperature control system can separate the operator menu from the supervisor menu, which can locate the respective responsibility of the operating parameter and the article storage.  The inbuilt lithium accumulator can keep displaying the temperature inside the box and can keep the light and sound alarm available for 72 hours after electricity failure. Optional items:  The EPS emergency supply is adoptable;  The DC24V-AC220V inverter is adoptable, and the DC24V power supply can keep the refrigerator under normal operation. Refrigeration system  Import and adopt the original binding Germany DANFOSS high-performance compressor;  Germany “EBM” heat elimination fan  Import and adopt the Japanese Matsushita vaporizer (cooling pipeline inside the box);  Fluoride-free refrigeration system for environmental protection to make green products and create green world Humanization design  The large-screen design is easy for observation.  The safe lock design can prevent missing-opening.  Wide voltage band is available for 187-242V voltage.  The refrigerator body is made of high-quality structural steel plate, which is treated with advanced phosphate rot-proof spray coating processing. The surface color is soft.
  6. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com Main technical parameter: Product model Total useful volume Voltage Climate type Input power Temperature inside the box Exterior size (W*D*H) Weight LA-HV80-120 120L 220V/50~60HZ N 1300W -10~-80°C 1330×720×950 140kg LA-HV80-200 200L 220V/50~60HZ N 1500W -10~-80°C 1600×720×950 160kg LA-HV- 86-120 120L 220V/50~60HZ N 1500W -10~-86°C 1330×720×950 140kg 3. Plant Photosynthesis Meter Model:LA-3051C Characteristic and usage The Plant Photosynthesis Meter applies for measuring Photosynthesis rate of crops, fruits and vegetables, grass etc. Features  Special setting: advanced MCU, Lattice LCD widescreen display, menu display and cursor operation.  Use-friendly: small in size, light-weight, portable, single-person operation, clear connection of gas circuit and electrical circuit, the leaf chamber open and lock automatically.  Excellent performance: high stability, accuracy, repeatability, and good time response. It is able to measure simultaneously Pn, CO2, PAR, T etc.  Widely application: equip different type leaf chamber, it can widely apply for field crop, fruits and vegetables, forest and wood, grass etc. equip standard maintain-free Li-Ion, AC /DC are available.
  7. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com Components Host machine, handle, leaf chamber, Gas path pipes, Charger, SD card Technical parameters Testing parameter Measure range accuracy CO2 0-1500PPm 0.1ppm Leaf temperature 0-50℃ 0.2℃ Air Temperature 0-50℃ 0.2℃ PAR 0-2500μmolm-2•s-1 <5μmolm-2•s-1 RH(chamber humidity) 0-100% 2% 4. GC-7960 Gas Chromatograph The instrument adopts large screen LCD monitor, audio-visual display, easy operation. Meanwhile the instrument is with digital interface, through one piece of communication cable realizing real-time data and signal acquisition, data processing and testing result on the computer. The artistic and compact appearance design, equipped with modern computer control technology, which makes GC-7960 become veritable, new type and high performance gas chromatograph. 1. Main technical characteristics: (1) The instrument adopts large screen LCD technology, audio-visual display, easy operation. (2) Self-diagnostic function, show trouble location. (3) Touching type keyboard is convenient for the user to set the operating data (4) Data power failure protection function, the operating data set by the instrument could be
  8. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com saved for long time after power failure. (5) Has the function of stopwatch. (6) Has the over temperature protection device. When the temperature is over setting limit, the instrument will stop heating and report malfunction on the display. (7) Large screen liquid crystal Chinese display shows the instrument parameter intuitively , greatly convenient for the user to set parameters, such as each channel temperature, heating, detector, bridge current, etc; Intuitively operate the functions, such as FID auto ignition, on-off bridge current, open and close temperature control, open and close heating and each time event, etc. (8) The instrument computer is connected with the internet, which could connect with instrument by remote computer, realizing remote data acquisition and management, improving the degree of freedom of the device, promoting the effective application of laboratory. (9) Main control circuit adopts advanced microprocessor, large capacity of Memory, making the data saving more reliable. Meanwhile integrated design that integrating the measurement , control , power supply in one piece of circuit board, improve the anti-interference performance and reliability of instrument. (10) Adopt temperature controlling circuit of microprocessor, temperature accuracy of controlled object each heating zone reach 0.1 degree. (11) Intelligent double back opening door technology, ensure that instrument column box temperature has good temperature control accuracy, and could cool quickly. (12) Eight steps program heating, fitting for analysis of complex samples of wide boiling point. (13) Unit type integral structure design, convenient installation and maintenance. (14) Large volume column box, could install four pieces of chromatographic column at the same time. (15) Instrument design is reasonable and flexible, could install three types of detectors simultaneously, and has independent electrical system, signal output end. (16) Flexible packed column and capillary column system, could connect with capillary column in different calibers. 2. Main technical index: (1) Temperature control index: Column box : At room temperature 8℃-420℃ Precision ±0.1℃ (Measure when at 200℃) Sample injector : At room temperature 8℃-420℃ Precision ±0.1℃ (Measure when at 200℃) Detector :At room temperature 8℃-420℃ Precision ±0.1℃ (Measure when at 200℃) Maximum six channels control temperature: apply to multichannel control temperature requirements, such as equipped with conversion furnace. (2) Column heater parameters: Temperature control accuracy: At room temperature 8℃-399℃Precision ±0.1℃ Column heater volume: 260mm×260mm×250mm Program heating step : 5 steps Program heating rate: 1℃-40℃
  9. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com Each step constant temperature hold time: 0-300min(1min increment ) Automatic back opening door design, ensure cooling quickly. High-power and low noise rotate fan, ensure the uniformity of temperature. (3) Stable double pneumatic system: Carrier gas flow adopts double stable design that voltage stabilization first and then current stabilization. Precise graduated pneumatic control valve is of high reproducibility and high stability. (4) Multiple sampling methods are optional: six-way valve gas sampling (5) Five detectors are optional. Hydrogen flame ionization detector (FID) : is used in the organics analysis of hydrocarbons industry and other fields. Thermal conductivity detector(TCD): is used in macro analysis of gas, liquid. Nitrogen phosphorus detector(NPD):is used in detection of trace nitrogen and phosphorus compounds. Flame photometric detector (FPD):is used in detection of trace sulfur and phosphorus compounds. Electron capture detector (ECD): detect the compound which could capture electrons. 3. High sensitivity detector parameter ensure the accuracy of data Parameter↓ Detector→ Hydrogen flame ionization detector (FID) Thermal conductivity detector (TCD) Electron capture detector (ECD) Flame photometric detector (FPD) Nitrogen phosphorus detector (NPD) Maximum service temperature 420℃ 400℃ 350℃ 400℃ 400℃ Limit of detection ≤2×10-12 g/s ≥3000mvml/mg ≤1×10-13 g/ml( r-666) Mp≤5×10-12 g/s Ms≤5×10-11 g/s Mn≤5×10-13 g/ sMp≤1×10-12 g /s Baseline drift ≤0.10mv ≤0.15mv ≤0.10mv ≤0.15mv ≤0.15mv Baseline noise ≤0.015mv ≤0.015mv ≤0.02mv ≤0.02mv ≤0.02mv Linearity range ≥106 ≥104 ≥104 ≥103 ≥103 Technical feature Auto ignition, Capillary nozzle is of high response Imported rhenium tungsten constant current circuit Ni63 radioactive source with cleaning gas circuit Top photomultiplier microanalysis Other parameters: Dimension: 680*480*500mm Total weight:65 kg Input power: AC 200V±10% 50HZ 1800W
  10. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 4. Supplying List Item Specification QTY Unit GC-7960 Gas Chromatograph GC Main Instrument. Gas Controlling System, Inlet System, Controlling Circuit, CPU Controller, Output System 1 Set Column Capillary Column 1 Set Detector ECD 1 Set Gas Source Gas Generator or Gas Tank 1 Set Working Station SP-2000 dual channel & multi-function working station 1 Set Software methane gas analysis software package 1 Set 5. Intelligent Leaf Area Meter Model: LA-YMJ-C Characteristics: The system of intelligent leaf area meter consists of a backlight apparatus and a tablet computer embedded application software (android). The APP is synthesis software; it adopts advanced image processing technology, and through the principles of leaves shapes drawing, space transformation and edge detection, and morphology as well. The instrument is used for measuring leaf area and other values. Technical parameters Suitable range: varying size of green, yellow, red or other colors for plant leaves. Measuring range: 5~100 CM2 Measured max length: 20cm
  11. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com Measured max width: 15cm The accuracy for counting worm hole: ±2% App Features 1. Android system, it is easy and quick to handle with more intelligent, humanized and can be upgraded applied functions 2. 7inchs full-color touch-screen, 8 million pixels. After taking photo, the software will count and display the value automatically. 3. Powerful storage functions with 16G SD Card. 4. View the data with report and Excel format. 5. Manual fixed the leaf shape to ensure a high accuracy counting. 6. Three algorithms optional: general, dark color and light color. After taking photo, choose the suitable algorithm according the leaf’s color. 7. After taking photo, the software could count and display leaf area, perimeter, length, width, quantity of worm holes automatically. Tablet Computer Parameters System: Android4.2.2 above Size: 7inch full-color touch-screen Rear camera: 800million Resolution: 1920*1200 Storage: 16G Network interface: WiFi/ 4G Power supply: DC5V1A
  12. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 6. -25°C Laboratory Freezer (Upright) Precise temperature control system  The worldwide famous high-accuracy computer-controlled temperature system with original binding can maintain the temperature constancy in the box;  The value is to be displayed through three-digital high-brightness figure. The temperature set-value can be moderately adjusted at -10°C ~ -25°C, and the temperature display precision is 0.1°C, the resolution is 0.1°C and the adjusting increment is 0.1°C.  The system has special high-resolution temperature calibrating function. The calibrating increment is 0.1°C.  Platinum resistance temperature sensor is accurate and with stable performance. 24-hours tracing, recording and printing system [Optional]  The imported temperature recording and printing system. There are four precise temperature sensors (two sensors for some systems) inside the box and two temperature indicators outside the box, which are to display the temperature of upper and lower point, for users to supervise the temperature at each operating states in the box. The display precision--resolution is 0.1°C.  The distinguished power-off memory function can hold and store huge temperature data and information permanently.
  13. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com  The temperature printing has password protection function, which can prevent illegally printing of the temperature fluctuation information.  5-ways alarm system; the alarm devices with 12V power supply and220V power supply can trigger alarm simultaneously, which ensures super complementary supervision.  The remote signal alarm system (Optional)  The data management software is available for one or more temperature signals changes  Single channel / dual channel / multi-channel temperature data sheet management software  Communicate with PC through RS-232 interface to examine the temperature curve diagnosis diagram of one or more refrigerators and display the data sheet. The data and images can be stored, inquired and printed [Optional]. Safe control system  Keyboard lock and password protection function against missing-adjustment of the operating parameter;  Free setting of the alarm temperature range; 7 system failure alarms (high temperature alarm, low temperature alarm, sensors failure alarm, door-opening alarm, electricity failure alarm, low back-up battery alarm, low voltage alarm), code display of the failure position (some machines have all these seven alarms);  Three alarm ways (buzzer alarm, flashing alarm, remote signal alarm)  The starting delay function due to self-checking and the interval protection function between temporary stop and start can ensure the reliable operation;  Quick freezing function;  The system can record the condition of the maximum and the minimum temperature inside the box automatically without recording paper.  With the specially designed function, the system can operate under the state of sensor failure or the state of numerical disturbance safely and automatically.  The operating parameter display function can ensure that the system is under supervision by operator and with security and stability.  Special power-off memory function;  Equipped with remote alarm interface;  The distinguished operating parameter of the temperature control system can separate the operator menu from the supervisor menu, which can locate the respective responsibility of the operating parameter and the article storage.  The inbuilt lithium accumulator can keep displaying the temperature inside the box and can keep the light and sound alarm available for 72 hours after electricity failure. Optional items:  The EPS emergency supply is adoptable;
  14. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com  The DC24V-AC220V inverter is adoptable, and the DC24V power supply can keep the refrigerator under normal operation. Refrigeration system  Import and adopt the original binding Germany DANFOSS high-performance compressor;  Germany “EBM” heat elimination fan;  Import and adopt the Japanese Matsushita vaporizer (cooling pipeline inside the box);  The evaporator from top to bottom ensures effective flow of refrigerant;  Fluoride-free refrigeration system for environmental protection to make green products and create green world. Humanization design  The adjustable shelves are easy for storing items;  The large-screen design is easy for observation.  Double door inside and outside can lock the air-conditioning, and strengthen thermal insulation effect.  The safe lock design can prevent missing-opening.  The castor offers convenience for movement;  Wide voltage band is available for 187-242V voltage.  Extra-thick insulation layer ensures good insulation effect;  The refrigerator body is made of high-quality structural steel plate, which is treated with advanced phosphate rot-proof spray coating processing. The surface color is soft. Main technical parameter: Model Volume Voltage Climate Type Inner Temp. Exterior Size (W×D×H) Weight Cooling Method LA-DW25-120 120L 220V/50~60HZ N -10~ -25°C 600×690×1550 60kg Direct Cooling LA-DW25-170 170L 220V/50~60HZ N -10~ -25°C 600×690×1650 65kg Direct Cooling LA-DW25-200 200L 220V/50~60HZ N -10~ -25°C 600×690×1750 70kg Direct Cooling LA-DW25-260 260L 220V/50~60HZ N -10~ -25°C 600×690×1850 75kg Direct Cooling LA-DW25-440 440L 220V/50~60HZ N -10~ -25°C 700×690×1960 120kg Direct Cooling
  15. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 7. Portable core drill kits Component: Items Quantity Brush 1pc Spanner 2pcs Tape 3meters scraper 1pc hand shank 1pc soil sampling 1pc connector 4pcs sample depth: 2 meters
  16. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 8. LB series 0.1mg Analytical Balance Picture: Description: The LB series analysis balances adopt electromagnetic balances sensor, equipped with characteristics such as high accuracy, well-adapted, linear four point calibration, counting, unit converting and so on. Improve the traditional classification component circuit board to large digital integration, then the balances can have a higher stability and reaction speed, it also can adjust integration and sensitivity as user’s need. This series balances also equipped with standard RS232C data interface which can connect with micro-computer, printer and the other device. It can be widely used in varies fields such as university, biological medicine, enterprise and public institution, quarantine inspection. Features a) The electromagnetic force balance sensor. b) Available calibration weight. c) Automatic Calibration System. d) All weighing tarring. e) 4 level shockproof. f) Counting function, it can transfer 3 different units.(Gram, Ounce, Karat) g) The blue large backlighting LCD screen display (120*55 mm), completely display function. h) With the sensor technology of German STL software, supporting muti-point correction, ensure a more stability performance. i) The windshield of all around antistatic coating can effectively shield the the electrostatic interference, ensure a clear vision. j) The built-in RS232 standard interface can connect to the printer, computer and etc.
  17. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com k) It supports the unit transformation among Carat, ounce and grams. l) Overall dimension: 320*200*290 mm m) Weight: 7.5 kg n) Power: 220V/50Hz Standard accessories: balance, scale plate, adapter, instruction manual, qualification certificate, warranty card, standard weight, cleaning cloth, brush and forceps. Specifications: Model LB1004B LB1204B LB2004B LB2204B weighing range 0~100g 0~120g 0~200g 0~220g Readability 0.1mg 0.1mg 0.1mg 0.1mg Pan Size φ80mm φ80mm φ80mm φ80mm Output interface Rs232C Rs232C Rs232C Rs232C Net weight 6.8kg 6.8kg 6.8kg 6.8kg Package size 480*375*515 480*375*515 480*375*515 480*375*515 Work space height 240mm 240mm 240mm 240mm Dimension 350*215*340m 350*215*340m 350*215*340m 350*215*340m Model LB1104B LB2104B LB2004S weighing range 0~110g 0~210g 0~100g/100g-200g Readability 0.1mg 0.1mg 0.1mg Pan Size φ80mm φ80mm φ80mm Output interface Rs232C Rs232C Rs232C Net weight 6.8kg 6.8kg 6.8kg Package size 480*375*515 480*375*515 480*375*515 Work space height 240mm 240mm 240mm Dimension 350*215*340m 350*215*340m 350*215*340m
  18. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 9. Portable pH/mV Meter Order ID: LA-PHscan 221-UK Product description:  Standard pH/mV Meter  Measuring range: -2.000~20.000pH (±0.002pH)  mV: -1999.9~1999.9mV(±0.2mV)  Temperature range: 0~105 o C (±0.5o C)  1 to 5 keys calibration, automatic identification pH buffer solution, automatic temperature compensation, automatic end point locking, optional ORP measurement mode, temperature unit, pH buffer solution standard, display resolution and stability criteria, automated standard prompt, automated information prompt, can consult electrode information, a key to restore the factory pattern, timing or manually shut machine, 500 groups of data storage, USB communication interface, comply with GLP norms Standard configuration:  P11 type pH electrode (made in UK)  Temperature probe  pH standardbuffersolution(pH4.01/7.00/10.01)  Carrying case and Battery
  19. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 10. LA-DHG Electrothermal thermostatic blast drying oven Order ID: LA-DHG Application Range: This product is applied in industrial & mineral enterprises, laboratories and scientific research units for drying, baking, wax melting and disinfection. Structure Characteristics: 1. Stainless steel chamber. Easy-to-clean. 2. Overheating protection system. Microchip intelligent temperature controller with PV/SV display. 3. Inlet vent can be switched freely. Good air path design. Uniform temperature. 4. Rectangle observation window for easy observation of the samples in the inner chamber 5. Silicon sealing ring for reliable sealing. 6. Using the selectable temperature switch, select reasonable stage depending on the speed and heating temperature. Technical Parameters: Temperature fluctuation:±1°C. Temperature uniformity:±2.5°C%. Model Package Size (cm) Overall Dimension (cm) Operation Room Size (cm) Rated Power (KW) Tempe. Range (°C) Shelve s NW/GW (KG) Notes LA-DHG-9023A 70×60×60 58×50×45 25/30×30×28 0.32 RT+10°C~200°C 2 27/51 LA-DHG-9053A 82×66×69 71×56×53 54/42×37×35 0.6 RT+10°C~200°C 2 36/66 LA-DHG-9123A 90×76×98 83×61×72 137/50×50×55 1.2 RT+10°C~200°C 2 69/115 LA-DHG-9203A 98×78×95 88×78×82 213/60×55×64. 1.6 RT+10°C~200°C 2 95/135
  20. Labmen instrument Limited Tel:00852-30623001, Fax:00852-31828558 Email: sale@lab-men.com Site: www.lab-men.com 5 LA-DHG-9030A 53×53×77 42×51×63 31.5/30×30×35 0.7 RT+10°C~200°C 2 Vertical LA-DHG-9070A 59×61×84 52×61×73 72/40×40×45 1 RT+10°C~200°C 2 Vertical LA-DHG-9140A 65×76×94 67×66×83 136/45×55×55 1.6 RT+10°C~200°C 2 Vertical LA-DHG-9240A 83×86×123 72×71×100 225/50×60×75 2 RT+10°C~200°C 2 Vertical LA-DHG-9420A 93×81×178 72×66×165 429/60×55×13 0 2.6 RT+10°C~200°C 2 Vertical LA-DHG-9620A 113×86×17 8 92×76×165 624/80×60×13 0 3.6 RT+10°C~200°C 2 Vertical LA-DHG-9036A 53×53×77 42×51×63 31.5/30×30×35 0.95 RT+10°C~300°C 2 Vertical LA-DHG-9076A 59×61×84 52×61×73 72/40×40×45 1.4 RT+10°C~300°C 2 Vertical LA-DHG-9146A 65×76×94 67×66×83 136/45×55×55 2 RT+10°C~300°C 2 Vertical LA-DHG-9246A 83×86×123 72×71×100 225/50×60×75 2.6 RT+10°C~300°C 2 Vertical LA-DHG-9426A 93×81×178 72×66×165 429/60×55×13 0 3.5 RT+10°C~300°C 2 Vertical LA-DHG-9626A 113×86×17 8 92×76×165 624/80×60×13 0 5.7 RT+10°C~300°C 2 Vertical Labmen instrument Limited Add: RM18W, 27/F,Ho King Comm CTR, 2-16 Fayuen ST,Mongkok Kowloon, Hong Kong Tel:00852-30623001 Fax:00852-31828558 Email: sale@lab-men.com(sale information & quotation) info@lab-men.com (products information & visiting support) service@lab-men.com(after sale service) Site: www.lab-men.com skype: lormanled
Anúncio