Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
1. Intelligent Artificial Climate Incubator Series
Model: LA-RTOP-B/D series
Characteristics:
1. Aluminum alloy frame, delicate appearance, user-friendly.
2. Automatic microcomputer control; touch key,
3. Can set time, temperature, humidity, illuminance.
4. Can display experiment cycle, set time actual temperature and humidity (automatic
humidifying and
dehumidifying),set temperature, remaining time, actual temperature and illuminance level. With
periodic transformation function
5. Has overheating and sensor Abnormal protection function. Ensure the instrument and same
secure.
6. Full spectrum plant growth lamp, helpful for plants growth and improve the disease resistance
7. Has power failure memory, power failure time automatic compensation function; power on
after power cut, can continue the original work state
Intelligent Artificial Climate Incubator Series Technical parameters:
Temperature range: 0-50°C
Temperature fluctuation: ±0.5
Temperature uniformity: ±1°C
Humidity range: 50-95%
Humidity fluctuation: ±5%RH
Deviation: ±5%RH
Temperature, humidity, light can be programmed to periods:
Type B can be divided into day (period 01) and night(period 02)
Type D can be divides into 1-30 periods (include all functions of type B)
Light grade: 0-3 grade (strong light: 0-8 grade)
Light intensity: 0-5500LUX (normal)
(Type 1: 0-12000LUX)
Type 2:0- 22000LUX)
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
Heating power: 500W (RTOP-1000: 1000W)
Compressor power: 190W-320W
Compressor delay guard time: 3min
Noise: <70Db
Humidifier water tank capacity: 5L
Working mode: continuous operation (compressor intermittent working)
Working environment: temperature 0-40°C, humidity<80%RH Non-corrosiveness gas
Power: 220±22V, 50±0.5HZ
Intelligent Artificial Climate Incubator Series Model difference
Model Volume Size(mm)
Period control
mode
Illuminance(LUX)
LA-RTOP-150B
150L 520*550*41600
Day period
and night
period,
automatic
1-30 periods
automatic.
0-3000-5500
can choose 3000LUX for
seed germinating: can
choose 5500LUX for
seedling germinating.
illuminance of incubators
can be increased by user
requirement.
LA-RTOP-150D
LA-RTOP-260B 270L 590*590*1655
LA-RTOP-260D 590*590*1655
LA-RTOP-268B 268L 590*590*1655
LA-RTOP-268D 590*590*1655
LA-RTOP-280B 280L 590*590*1695
LA-RTOP-280D 590*590*1695
LA-RTOP-300B 300L 590*590*1785
LA-RTOP-300D 590*590*1785
LA-RTOP-310B
310L
590*590*1785
LA-RTOP-310D 590*590*1785
LA-RTOP-380B
380L 660*660*1770
LA-RTOP-380D
LA-RTOP-430B 430L 660*660*1890
LA-RTOP-430D 660*660*1890
LA-RTOP-500B
500L
692*692*2000
LA-RTOP-500D 692*692*2000
LA-RTOP-800B
800L
1265*650*1850
LA-RTOP-800D 1265*650*1850
LA-RTOP-1000B
1000L 1260*660*1985
LA-RTOP-1000D
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
2. -80°C &-86°C Chest Freezer
Order No.:LA-HV-N80
Precise temperature control system
The worldwide famous high-accuracy computer-controlled temperature system with original
binding can maintain the temperature constancy in the box at -80°C precisely. The
temperature set-value can be adjusted at -10°C~-80°C, and the temperature display
precision is 1°C, the resolution is 1°C and the adjusting increment is 1°C. The value is to be
displayed through three-digital high-brightness figure.
The system has special high-resolution temperature calibrating function. The calibrating
increment is 1°C.
24-hours tracing, recording and printing system (Optional)
The imported temperature recording and printing system. There are four precise
temperature sensors (two sensors for some systems) inside the box and two temperature
indicators outside the box, which are to display the temperature of upper and lower point,
for users to supervise the temperature at each operating states in the box. The display
precision--resolution is 1°C.
The distinguished power-off memory function can hold and store huge temperature data
and information permanently.
The temperature printing has password protection function, which can prevent illegally
printing of the temperature fluctuation information.
5-ways alarm system: including 2 sound alarm devices with 220V power supply, 2 light alarm
devices with 220V power supply and one remote signal alarm apparatus (optional),
consisting the super complementary supervision system.
The data management software is available for one or more temperature signals changes
Communicate with PC through RS-232 interface to examine the temperature curve diagnosis
diagram of one or more refrigerators and display the data sheet. The data and images can be
stored, inquired and printed (Optional).
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
Safe control system
Keyboard lock, password protection function, and method against missing-adjustment of the
operating parameter;
Setting of the alarm temperature range
7 system failure alarms (high temperature alarm, low temperature alarm, sensors failure
alarm, door-opening alarm, electricity failure alarm, low back-up battery alarm, low voltage
alarm).
Code display of the failure position (some machines have all these seven alarms)
Three alarm ways (buzzer alarm, flashing alarm, remote signal alarm)
The starting delay function due to self-checking and the interval protection function
between temporary stop and start can ensure the reliable operation
The system can record the condition of the maximum and the minimum temperature inside
the box automatically without recording paper.
With the specially designed function, the system can operate under the state of sensor
failure or the state of numerical disturbance safely and automatically.
The operating parameter display function can ensure that the system is under supervision by
operator and with security and stability.
Equipped with remote alarm interface
The distinguished operating parameter of the temperature control system can separate the
operator menu from the supervisor menu, which can locate the respective responsibility of
the operating parameter and the article storage.
The inbuilt lithium accumulator can keep displaying the temperature inside the box and can
keep the light and sound alarm available for 72 hours after electricity failure.
Optional items:
The EPS emergency supply is adoptable;
The DC24V-AC220V inverter is adoptable, and the DC24V power supply can keep the
refrigerator under normal operation.
Refrigeration system
Import and adopt the original binding Germany DANFOSS high-performance compressor;
Germany “EBM” heat elimination fan
Import and adopt the Japanese Matsushita vaporizer (cooling pipeline inside the box);
Fluoride-free refrigeration system for environmental protection to make green products and
create green world
Humanization design
The large-screen design is easy for observation.
The safe lock design can prevent missing-opening.
Wide voltage band is available for 187-242V voltage.
The refrigerator body is made of high-quality structural steel plate, which is treated with
advanced phosphate rot-proof spray coating processing. The surface color is soft.
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
Main technical parameter:
Product
model
Total
useful
volume
Voltage
Climate
type
Input
power
Temperature
inside the box
Exterior size
(W*D*H)
Weight
LA-HV80-120 120L 220V/50~60HZ N 1300W -10~-80°C 1330×720×950 140kg
LA-HV80-200 200L 220V/50~60HZ N 1500W -10~-80°C 1600×720×950 160kg
LA-HV-
86-120
120L 220V/50~60HZ N 1500W -10~-86°C 1330×720×950 140kg
3. Plant Photosynthesis Meter
Model:LA-3051C
Characteristic and usage
The Plant Photosynthesis Meter applies for measuring Photosynthesis rate of crops, fruits and
vegetables, grass etc.
Features
Special setting: advanced MCU, Lattice LCD widescreen display, menu display and cursor
operation.
Use-friendly: small in size, light-weight, portable, single-person operation, clear connection
of gas circuit and electrical circuit, the leaf chamber open and lock automatically.
Excellent performance: high stability, accuracy, repeatability, and good time response. It is
able to measure simultaneously Pn, CO2, PAR, T etc.
Widely application: equip different type leaf chamber, it can widely apply for field crop,
fruits and vegetables, forest and wood, grass etc. equip standard maintain-free Li-Ion, AC
/DC are available.
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
Components
Host machine, handle, leaf chamber, Gas path pipes, Charger, SD card
Technical parameters
Testing parameter Measure range accuracy
CO2 0-1500PPm 0.1ppm
Leaf temperature 0-50℃ 0.2℃
Air Temperature 0-50℃ 0.2℃
PAR 0-2500μmolm-2•s-1 <5μmolm-2•s-1
RH(chamber humidity) 0-100% 2%
4. GC-7960 Gas Chromatograph
The instrument adopts large screen LCD monitor, audio-visual display, easy operation. Meanwhile
the instrument is with digital interface, through one piece of communication cable realizing
real-time data and signal acquisition, data processing and testing result on the computer. The
artistic and compact appearance design, equipped with modern computer control technology,
which makes GC-7960 become veritable, new type and high performance gas chromatograph.
1. Main technical characteristics:
(1) The instrument adopts large screen LCD technology, audio-visual display, easy operation.
(2) Self-diagnostic function, show trouble location.
(3) Touching type keyboard is convenient for the user to set the operating data
(4) Data power failure protection function, the operating data set by the instrument could be
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
saved for long time after power failure.
(5) Has the function of stopwatch.
(6) Has the over temperature protection device. When the temperature is over setting limit, the
instrument will stop heating and report malfunction on the display.
(7) Large screen liquid crystal Chinese display shows the instrument parameter intuitively ,
greatly convenient for the user to set parameters, such as each channel temperature,
heating, detector, bridge current, etc; Intuitively operate the functions, such as FID auto
ignition, on-off bridge current, open and close temperature control, open and close heating
and each time event, etc.
(8) The instrument computer is connected with the internet, which could connect with
instrument by remote computer, realizing remote data acquisition and management,
improving the degree of freedom of the device, promoting the effective application of
laboratory.
(9) Main control circuit adopts advanced microprocessor, large capacity of Memory, making the
data saving more reliable. Meanwhile integrated design that integrating the measurement ,
control , power supply in one piece of circuit board, improve the anti-interference
performance and reliability of instrument.
(10) Adopt temperature controlling circuit of microprocessor, temperature accuracy of controlled
object each heating zone reach 0.1 degree.
(11) Intelligent double back opening door technology, ensure that instrument column box
temperature has good temperature control accuracy, and could cool quickly.
(12) Eight steps program heating, fitting for analysis of complex samples of wide boiling point.
(13) Unit type integral structure design, convenient installation and maintenance.
(14) Large volume column box, could install four pieces of chromatographic column at the
same time.
(15) Instrument design is reasonable and flexible, could install three types of detectors
simultaneously, and has independent electrical system, signal output end.
(16) Flexible packed column and capillary column system, could connect with capillary column in
different calibers.
2. Main technical index:
(1) Temperature control index:
Column box : At room temperature 8℃-420℃ Precision ±0.1℃ (Measure when at 200℃)
Sample injector : At room temperature 8℃-420℃ Precision ±0.1℃ (Measure when at 200℃)
Detector :At room temperature 8℃-420℃ Precision ±0.1℃ (Measure when at 200℃)
Maximum six channels control temperature: apply to multichannel control temperature
requirements, such as equipped with conversion furnace.
(2) Column heater parameters:
Temperature control accuracy: At room temperature 8℃-399℃Precision ±0.1℃
Column heater volume: 260mm×260mm×250mm
Program heating step : 5 steps
Program heating rate: 1℃-40℃
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
Each step constant temperature hold time: 0-300min(1min increment )
Automatic back opening door design, ensure cooling quickly.
High-power and low noise rotate fan, ensure the uniformity of temperature.
(3) Stable double pneumatic system:
Carrier gas flow adopts double stable design that voltage stabilization first and then current
stabilization.
Precise graduated pneumatic control valve is of high reproducibility and high stability.
(4) Multiple sampling methods are optional:
six-way valve gas sampling
(5) Five detectors are optional.
Hydrogen flame ionization detector (FID) : is used in the organics analysis of hydrocarbons
industry and other fields.
Thermal conductivity detector(TCD): is used in macro analysis of gas, liquid.
Nitrogen phosphorus detector(NPD):is used in detection of trace nitrogen and phosphorus
compounds.
Flame photometric detector (FPD):is used in detection of trace sulfur and phosphorus compounds.
Electron capture detector (ECD): detect the compound which could capture electrons.
3. High sensitivity detector parameter ensure the accuracy of data
Parameter↓
Detector→
Hydrogen
flame
ionization
detector
(FID)
Thermal
conductivity
detector
(TCD)
Electron
capture
detector
(ECD)
Flame
photometric
detector
(FPD)
Nitrogen
phosphorus
detector
(NPD)
Maximum
service
temperature
420℃ 400℃ 350℃ 400℃ 400℃
Limit of
detection
≤2×10-12
g/s ≥3000mvml/mg
≤1×10-13
g/ml(
r-666)
Mp≤5×10-12
g/s
Ms≤5×10-11
g/s
Mn≤5×10-13
g/
sMp≤1×10-12
g
/s
Baseline drift ≤0.10mv ≤0.15mv ≤0.10mv ≤0.15mv ≤0.15mv
Baseline noise ≤0.015mv ≤0.015mv ≤0.02mv ≤0.02mv ≤0.02mv
Linearity range ≥106
≥104
≥104
≥103
≥103
Technical
feature
Auto ignition,
Capillary
nozzle is of
high response
Imported
rhenium
tungsten
constant current
circuit
Ni63
radioactive
source with
cleaning gas
circuit
Top
photomultiplier
microanalysis
Other parameters: Dimension: 680*480*500mm Total weight:65 kg Input power: AC 200V±10%
50HZ 1800W
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
4. Supplying List
Item Specification QTY Unit
GC-7960 Gas
Chromatograph
GC Main Instrument. Gas Controlling System, Inlet System,
Controlling Circuit, CPU Controller, Output System
1 Set
Column Capillary Column 1 Set
Detector ECD 1 Set
Gas Source Gas Generator or Gas Tank 1 Set
Working Station SP-2000 dual channel & multi-function working station 1 Set
Software methane gas analysis software package 1 Set
5. Intelligent Leaf Area Meter
Model: LA-YMJ-C
Characteristics:
The system of intelligent leaf area meter consists of a backlight apparatus and a tablet computer
embedded application software (android). The APP is synthesis software; it adopts advanced
image processing technology, and through the principles of leaves shapes drawing,
space transformation and edge detection, and morphology as well. The instrument is used for
measuring leaf area and other values.
Technical parameters
Suitable range: varying size of green, yellow, red or other colors for plant leaves.
Measuring range: 5~100 CM2
Measured max length: 20cm
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
Measured max width: 15cm
The accuracy for counting worm hole: ±2%
App Features
1. Android system, it is easy and quick to handle with more intelligent, humanized and can be
upgraded applied functions
2. 7inchs full-color touch-screen, 8 million pixels. After taking photo, the software will count
and display the value automatically.
3. Powerful storage functions with 16G SD Card.
4. View the data with report and Excel format.
5. Manual fixed the leaf shape to ensure a high accuracy counting.
6. Three algorithms optional: general, dark color and light color. After taking photo, choose the
suitable algorithm according the leaf’s color.
7. After taking photo, the software could count and display leaf area, perimeter, length, width,
quantity of worm holes automatically.
Tablet Computer Parameters
System: Android4.2.2 above
Size: 7inch full-color touch-screen
Rear camera: 800million
Resolution: 1920*1200
Storage: 16G
Network interface: WiFi/ 4G
Power supply: DC5V1A
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
6. -25°C Laboratory Freezer (Upright)
Precise temperature control system
The worldwide famous high-accuracy computer-controlled temperature system with original
binding can maintain the temperature constancy in the box;
The value is to be displayed through three-digital high-brightness figure. The temperature
set-value can be moderately adjusted at -10°C ~ -25°C, and the temperature display
precision is 0.1°C, the resolution is 0.1°C and the adjusting increment is 0.1°C.
The system has special high-resolution temperature calibrating function. The calibrating
increment is 0.1°C.
Platinum resistance temperature sensor is accurate and with stable performance.
24-hours tracing, recording and printing system [Optional]
The imported temperature recording and printing system. There are four precise
temperature sensors (two sensors for some systems) inside the box and two temperature
indicators outside the box, which are to display the temperature of upper and lower point,
for users to supervise the temperature at each operating states in the box. The display
precision--resolution is 0.1°C.
The distinguished power-off memory function can hold and store huge temperature data
and information permanently.
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
The temperature printing has password protection function, which can prevent illegally
printing of the temperature fluctuation information.
5-ways alarm system; the alarm devices with 12V power supply and220V power supply can
trigger alarm simultaneously, which ensures super complementary supervision.
The remote signal alarm system (Optional)
The data management software is available for one or more temperature signals changes
Single channel / dual channel / multi-channel temperature data sheet management
software
Communicate with PC through RS-232 interface to examine the temperature curve diagnosis
diagram of one or more refrigerators and display the data sheet. The data and images can be
stored, inquired and printed [Optional].
Safe control system
Keyboard lock and password protection function against missing-adjustment of the
operating parameter;
Free setting of the alarm temperature range; 7 system failure alarms (high temperature
alarm, low temperature alarm, sensors failure alarm, door-opening alarm, electricity failure
alarm, low back-up battery alarm, low voltage alarm), code display of the failure position
(some machines have all these seven alarms);
Three alarm ways (buzzer alarm, flashing alarm, remote signal alarm)
The starting delay function due to self-checking and the interval protection function
between temporary stop and start can ensure the reliable operation;
Quick freezing function;
The system can record the condition of the maximum and the minimum temperature inside
the box automatically without recording paper.
With the specially designed function, the system can operate under the state of sensor
failure or the state of numerical disturbance safely and automatically.
The operating parameter display function can ensure that the system is under supervision by
operator and with security and stability.
Special power-off memory function;
Equipped with remote alarm interface;
The distinguished operating parameter of the temperature control system can separate the
operator menu from the supervisor menu, which can locate the respective responsibility of
the operating parameter and the article storage.
The inbuilt lithium accumulator can keep displaying the temperature inside the box and can
keep the light and sound alarm available for 72 hours after electricity failure.
Optional items:
The EPS emergency supply is adoptable;
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
The DC24V-AC220V inverter is adoptable, and the DC24V power supply can keep the
refrigerator under normal operation.
Refrigeration system
Import and adopt the original binding Germany DANFOSS high-performance compressor;
Germany “EBM” heat elimination fan;
Import and adopt the Japanese Matsushita vaporizer (cooling pipeline inside the box);
The evaporator from top to bottom ensures effective flow of refrigerant;
Fluoride-free refrigeration system for environmental protection to make green products and
create green world.
Humanization design
The adjustable shelves are easy for storing items;
The large-screen design is easy for observation.
Double door inside and outside can lock the air-conditioning, and strengthen thermal
insulation effect.
The safe lock design can prevent missing-opening.
The castor offers convenience for movement;
Wide voltage band is available for 187-242V voltage.
Extra-thick insulation layer ensures good insulation effect;
The refrigerator body is made of high-quality structural steel plate, which is treated with
advanced phosphate rot-proof spray coating processing. The surface color is soft.
Main technical parameter:
Model Volume Voltage Climate
Type
Inner
Temp.
Exterior Size
(W×D×H)
Weight Cooling
Method
LA-DW25-120 120L 220V/50~60HZ N -10~
-25°C
600×690×1550 60kg Direct
Cooling
LA-DW25-170 170L 220V/50~60HZ N -10~
-25°C
600×690×1650 65kg Direct
Cooling
LA-DW25-200 200L 220V/50~60HZ N -10~
-25°C
600×690×1750 70kg Direct
Cooling
LA-DW25-260 260L 220V/50~60HZ N -10~
-25°C
600×690×1850 75kg Direct
Cooling
LA-DW25-440 440L 220V/50~60HZ N -10~
-25°C
700×690×1960 120kg Direct
Cooling
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
8. LB series 0.1mg Analytical Balance
Picture:
Description:
The LB series analysis balances adopt electromagnetic balances sensor, equipped with
characteristics such as high accuracy, well-adapted, linear four point calibration, counting, unit
converting and so on. Improve the traditional classification component circuit board to large
digital integration, then the balances can have a higher stability and reaction speed, it also can
adjust integration and sensitivity as user’s need.
This series balances also equipped with standard RS232C data interface which can connect with
micro-computer, printer and the other device. It can be widely used in varies fields such as
university, biological medicine, enterprise and public institution, quarantine inspection.
Features
a) The electromagnetic force balance sensor.
b) Available calibration weight.
c) Automatic Calibration System.
d) All weighing tarring.
e) 4 level shockproof.
f) Counting function, it can transfer 3 different units.(Gram, Ounce, Karat)
g) The blue large backlighting LCD screen display (120*55 mm), completely display
function.
h) With the sensor technology of German STL software, supporting muti-point correction,
ensure a more stability performance.
i) The windshield of all around antistatic coating can effectively shield the the
electrostatic interference, ensure a clear vision.
j) The built-in RS232 standard interface can connect to the printer, computer and etc.
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
k) It supports the unit transformation among Carat, ounce and grams.
l) Overall dimension: 320*200*290 mm
m) Weight: 7.5 kg
n) Power: 220V/50Hz
Standard accessories:
balance, scale plate, adapter, instruction manual, qualification certificate, warranty card, standard
weight, cleaning cloth, brush and forceps.
Specifications:
Model LB1004B LB1204B LB2004B LB2204B
weighing range 0~100g 0~120g 0~200g 0~220g
Readability 0.1mg 0.1mg 0.1mg 0.1mg
Pan Size φ80mm φ80mm φ80mm φ80mm
Output interface Rs232C Rs232C Rs232C Rs232C
Net weight 6.8kg 6.8kg 6.8kg 6.8kg
Package size 480*375*515 480*375*515 480*375*515 480*375*515
Work space height 240mm 240mm 240mm 240mm
Dimension 350*215*340m 350*215*340m 350*215*340m 350*215*340m
Model LB1104B LB2104B LB2004S
weighing range 0~110g 0~210g 0~100g/100g-200g
Readability 0.1mg 0.1mg 0.1mg
Pan Size φ80mm φ80mm φ80mm
Output interface Rs232C Rs232C Rs232C
Net weight 6.8kg 6.8kg 6.8kg
Package size 480*375*515 480*375*515 480*375*515
Work space height 240mm 240mm 240mm
Dimension 350*215*340m 350*215*340m 350*215*340m
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
9. Portable pH/mV Meter
Order ID: LA-PHscan 221-UK
Product description:
Standard pH/mV Meter
Measuring range: -2.000~20.000pH (±0.002pH)
mV: -1999.9~1999.9mV(±0.2mV)
Temperature range: 0~105 o
C (±0.5o
C)
1 to 5 keys calibration, automatic identification pH buffer solution, automatic temperature
compensation, automatic end point locking, optional ORP measurement mode, temperature
unit, pH buffer solution standard, display resolution and stability criteria, automated
standard prompt, automated information prompt, can consult electrode information, a key
to restore the factory pattern, timing or manually shut machine, 500 groups of data storage,
USB communication interface, comply with GLP norms
Standard configuration:
P11 type pH electrode (made in UK)
Temperature probe
pH standardbuffersolution(pH4.01/7.00/10.01)
Carrying case and Battery
Labmen instrument Limited
Tel:00852-30623001, Fax:00852-31828558
Email: sale@lab-men.com Site: www.lab-men.com
10. LA-DHG Electrothermal thermostatic blast drying oven
Order ID: LA-DHG
Application Range:
This product is applied in industrial & mineral enterprises, laboratories and scientific research
units for drying, baking, wax melting and disinfection.
Structure Characteristics:
1. Stainless steel chamber. Easy-to-clean.
2. Overheating protection system. Microchip intelligent temperature controller with PV/SV
display.
3. Inlet vent can be switched freely. Good air path design. Uniform temperature.
4. Rectangle observation window for easy observation of the samples in the inner chamber
5. Silicon sealing ring for reliable sealing.
6. Using the selectable temperature switch, select reasonable stage depending on the speed
and heating temperature.
Technical Parameters:
Temperature fluctuation:±1°C.
Temperature uniformity:±2.5°C%.
Model
Package
Size (cm)
Overall
Dimension
(cm)
Operation
Room
Size (cm)
Rated
Power
(KW)
Tempe. Range
(°C)
Shelve
s
NW/GW
(KG)
Notes
LA-DHG-9023A 70×60×60 58×50×45 25/30×30×28 0.32 RT+10°C~200°C 2 27/51
LA-DHG-9053A 82×66×69 71×56×53 54/42×37×35 0.6 RT+10°C~200°C 2 36/66
LA-DHG-9123A 90×76×98 83×61×72 137/50×50×55 1.2 RT+10°C~200°C 2 69/115
LA-DHG-9203A 98×78×95 88×78×82 213/60×55×64. 1.6 RT+10°C~200°C 2 95/135