LaserCOMPACT ™
Listings/Approvals:
FM, LPC, SSL, UL, ULC, VdS
The LaserCOMPACT detector has been º Single air inlet port with air flow
specifically designed to provide all the monitoring device
benefits of aspirating smoke detection,
º Termination Card supporting three
including very early warning, in single
relays
environment small areas and where
- Fire
space is a premium. This has been
- Pre-alarm
achieved through the combination of
- Alert/Fault
a p p ro v e d L a s e r P LU S d e t e c t i o n
FEATURES technology, dual-stage air filtration
(including service and Isolate)
The card also includes power
º Reduced size technology and a modified aspirator
connections and VESDAnet
design incorporated into a smaller
º Absolute smoke detection communication connection on the
enclosure with a simplified display.
(VN) version
º Wide sensitivity range LaserCOMPACT is available in two
versions, one that interfaces via relays º LaserCOMPACT Aspirator
º Single pipe inlet
only (RO) or via the relays and VESDAnet º Dual-Stage Air Filter Cartridge
º Simple display (VN).
º Air Exhaust Port
º Referencing
Description The front cover supports
º VESDAnet The LaserCOMPACT is made up of two
communication (VN) parts: the main enclosure and the front º 5 LEDs:
º Dual stage dust filter cover. - Fire, Pre-Alarm/Alert, Fault, OK,
Reset/Isolate
º Three Alarm Levels The main enclosure houses all the key
components of the detector. All non- º Reset/Isolate Push Button (press to
º Programmable Relays reset, press and hold to isolate)
serviceable items like the main processor
º Air flow monitoring board and detector chamber are
mounted away from the general access How lt Works
º Optional remote display
area, protecting them during the Air is continually drawn through a simple
and relay capability
installation and service process. pipe network to a central detector by a
º Simple mounting design high efficiency aspirator. Air entering the
The main enclosure includes: unit passes a flow sensor before a sample
º AutoLearn™ º Laser Detection Chamber is passed through a dual-stage dust filter
º Main processor board with (the majority of air is exhausted from the
integrated flow sensor card detector and where required back vented
to the protected area). The first stage
removes dust and dirt from the air sample
before it enters the chamber for smoke
detection. The second ultra fine stage
provides a clean air supply to be used
inside the detection chamber to form
clean air barriers, which protect the optical
surfaces from contamination.
The detection chamber uses a stable,
highly efficient laser light source and
unique sensor configuration to achieve
the optimum response to a wide range of
smoke types. When smoke passes
through the detection chamber it creates
light scatter which is detected by the very
sensitive sensor circuitry.
The status of the detector, all alarms,
service and fault events, are monitored
and logged with time and date stamps.
Status reporting can be transmitted via
simple relay connections or across the
advanced VESDAnet communications
network (VN version only).
www.acornfiresecurity.com
2. www.acornfiresecurity.com
Supply Voltage: I 8 to 30VDC LaserCOMPACT TERMINATION CARD (VN)
Power Consumption: 5.4W quiescent, 5.9W with alarm
Current Consumption: 225mA quiescent, 245mA with alarm
Fuse Rating: I.6A
Dimensions (WHD): 225mm x 225mm x 85mm
(8 7/8” x 8 7/8”x 3 3/8”) Terminal A Terminal B
1 Bias (-) (GND) 1 Shield
Weight: 1.9kg (4.Zlbs.) 2 Reset (-) 2 VESDAnet-A (-)
3 Reset (+) 3 VESDAnet-A (+)
Operating Temperature: 4 Bias (+) 4 Shield
Detector Ambient -10°C to 39°C (14°F to 103°F) 5 LED (-) (GND) 5 VESDAnet-B (-)
6 LED (+) 6 VESDAnet-B (+)
Sampled Air -20°C to 60°C (-4°F to l40°F) 7 FIRE (NO) 7 Power (-)
8 FIRE (C) 8 Power (+)
Sampling Network: 9 PRE-ALARM (NO) 9 Power (-)
10 PRE-ALARM (C) 10 Power (+)
Maximum area of Coverage 800sq.m (8000sq.ft) 11 FAULT (NO)
Maximum Pipe lengths: 12 FAULT (C)
13 FAULT (NC)
1 x 80m
2 x 50m
Computer Design Tool: ASPIRE™
Pipe:
Internal Diameter 15-21mm (9/16” - 7/8”) LaserCOMPACT TERMINATION CARD (RO)
External Diameter 25mm (1”)
Relays:
3 Relays rated 2A 8 30VDC
Default Configuration
Fire Terminal A Terminal B
1 FIRE (NO) 1 Bias (-) (GND)
Pre-Atarm 2 FIRE (C) 2 Reset (-)
3 PRE-ALARM (NO) 3 Reset (+)
Alert/Fault (Maintenance & Isolate) 4 PRE-ALARM (C) 4 Bias (+)
Programmable 0 - 60 seconds time delay for each relay 5 FAULT (NO) 5 LED (-) (GND)
6 FAULT (C) 6 LED (+)
Software Programmable Relays: 7 FAULT (NC) 7 Power (-)
8 Power (+)
Latching or non-latching 9 Power (-)
10 Power (+)
IP Rating: IP30
Cable Access: 4 x 25mm (1”) cable entries
Cable Termination:
Screw Terminal blocks 0.2-2.5sq mm
(30-12 AWG)
Sensitivity Range:
0.005 to 20% obs/m
MOUNTING DIAGRAM (Rear View)
(0.0015 to 6% obs/ft)
205
Threshold Setting Range: mm
Alert: 0.005 - I .990% obs/m
(0.0015-0.6218% obs/ft)
Pre-Alarm: 0.010-1.995% obs/m
(0.0031-0.6234% obs/ft)
Fire: 0.015-20.00% obs/m (0.0046-6.25% obs/ft)*
*Limited to 4% obs/ft for UL
Software Features: Diameter
8mm
Event log: Up to l 2,000 events stored on FIFO Typ. (2)
Smoke level, alarms and faults with time and date stamp 225
mm
AutoLearn: Minimum 15 minutes, maximum I 5 days.
Recommended minimum 14 days.
During AutoLearn thresholds are NOT changed from pre-
112.5
set values. mm 95
mm
Configurable General Input (24VDC):
Standby, Mains OK and Reset/Isolate
Ordering Information:
VLC-505 VESDAnet Version (VN) 112.5
mm
VLC-500 Relays only Version (RO) 225
mm