SlideShare uma empresa Scribd logo
1 de 42
CONTROLLING THE LOCATION OF
HYDRAULIC JUMP IN RECTANGULAR
CHANNEL
SUBMITTED BY SUBMITTED TO
SIDDHARTH UPADHYAY Mr. S ANBU KUMAR
2K15/HFE/15 ASSOCIATE PROFESSOR
Department of Civil Engineering
INTRODUCTION
• Statistics and studies made by International Commission on Large
Dams (ICOLD) show that more than 20% of dam accidents occurred
due to poor provision of energy dissipation arrangements.
• Normally energy dissipators are designed for ‘design discharge’ of
spillway. But their performance is affected during varying discharge
condition.
• In majority of failure cases, the jump is not clear – i.e. jump is either
swept up or drowned.
• Our present study objective is to design a suitable design of
hydraulic jump type energy dissipator for tail water deficiency and
steady flow. This can largely reduce dependency on TWRC without
disconnecting it from JHC.
• Efforts are made to produce required JHC at all discharges to form
clear jumps.
Damaged stilling basin of sardar
sarovar dam
• Sardar Sarovar Project (SSP) is one of the major
projects in India. In the year 1999 it is reported
that during a flood in monsoon season, 10,000
m3 of concrete was washed out due to flood
flows.
• The design discharge of spillway is 87,000m3/s.
The flood was even lesser than 50% of the design
discharge.
• The approximate cost of concrete that washed
out was Rs. 3 crore
View of dislodged panel at Bhama askhed dam
Definition sketch of hydraulic jump
Design of rectangular stepped weir
(Section A-A earlier shown)
FORMULA USED FOR DETERMINATION OF DIMENSION
OF STEPPED WEIR
Classification of tail water conditions
for the design of energy dissipator
FACTORS AFFECTING HYDRAULIC
JUMP
Factors affecting hydraulic jump are
• Total head on upstream of sluice gate (H),
• Pre jump depth (y1) ,
• Post jump depth (y2),
• Crest height of weir (y'),
• Head over weir crest (h) and tail water depth (yt).
• Another non dimensional important parameter
that governs hydraulic jump phenomenon is
supercritical Froude number Fr1.
Dimensions and Data of model used in
fluent
Height of sluice gate H=0.4m,
Height of flume H’=0.45m
Width of flume B=0.3m,
Length of flume L=4m
Max discharge Qmax=0.01 m3/s,
Min discharge Qmin=0.002 m3/s,
Crest height of weir y'=0.015m
Table 1: Output of Mathematical Procedure for Data
(Horizontal apron and Cd = 0.623)
Sr. No. Q y1 y2 H Fr1 B
m3/s M M M M
1 0.0020 0.0024 0.0605 0.0455 18.3350 0.1119
2 0.0028 0.0033 0.0714 0.0564 15.4960 0.1336
3 0.0036 0.0043 0.0807 0.0657 13.6661 0.1463
4 0.0044 0.0052 0.0889 0.0739 12.3614 0.1569
5 0.005 0.0062 0.0965 0.0814 11.3709 0.1660
6 0.0060 0.0071 0.1034 0.0884 10.5857 0.1741
7 0.0068 0.0081 0.1098 0.0948 9.9435 0.1816
8 0.0076 0.0090 0.1159 0.1009 9.4056 0.1884
9 0.0084 0.0100 0.1216 0.1066 8.9466 0.1949
10 0.0092 0.010947 0.1270 0.1120 8.5487 0.2010
11 0.0100 0.011899 0.1322 0.1172 8.1997 0.2067
Stepped weir in fluent
Stepped weir in fluent
Stepped weir in flume
Inlet section in flume
Outlet section in flume
Hydraulic jump at discharge 0.0020 m3 /sec
Hydraulic jump at discharge 0.005 m3 /sec
Hydraulic jump at discharge 0.0068 m3 /sec
Hydraulic jump at discharge 0.0084 m3 /sec
Hydraulic jump at discharge 0.0092 m3 /sec
Hydraulic jump at discharge 0.010 m3 /sec
Table 2: Comparisons of post jump depth of experimental and
fluent value at Cd = 0.60
Test Discharge Post jump Post jump Tail water
No. Q m3/s Depth Depth depth
y2 m y2 m yt m
(Fluent) (experimental) (Fluent) (Fluent)
1 0.0100 0.132 0.1210 0.063
2 0.0092 0.1270 0.1161 0.059
3 0.0084 0.1216 0.1089 0.056
4 0.0068 0.1098 0.1040 0.049
5 0.0050 0.0968 0.0913 0.041
6 0.0040 0.0865 0.0869 0.035
7 0.0020 0.0605 0.0621 0.028
Comparisons of post jump depth of experimental and fluent
value at Cd = 0.60
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0 0.002 0.004 0.006 0.008 0.01 0.012
y2
Discharge (m3/s)
JHC Exp.
JHC fluent
Table 3: Comparisons of post jump depth of experimental and
fluent value at Cd = 0.65
Test Discharge Post jump Post jump Tail water
No. Q m3/s Depth depth Depth
y2 m y2 m yt m
(Fluent) (Experimental) (Fluent) (Fluent)
1 0.0100 0.1322 0.1140 0.0540
2 0.0092 0.1270 0.1110 0.0510
3 0.0084 0.1216 0.1035 0.0475
4 0.0068 0.1098 0.1010 0.0464
5 0.0050 0.0965 0.0850 0.0363
6 0.0040 0.0850 0.0810 0.0330
7 0.0020 0.0605 0.0587 0.0270
Comparison of Experimental and Fluent – JHC (y 2) at for
horizontal apron (Cd = 0.65)
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0 0.002 0.004 0.006 0.008 0.01 0.012
Post jump Depth y2 m (Experimental)
Post jump depth y2 m (Fluent)
Table 4 : Comparisons of post jump depth of experimental and
fluent value at Cd = 0.63
Test Discharge Post jump Post jump Tail water
No. Q m3/s Depth depth Depth
y2 m y2 m yt m
(Fluent) (Experimental) (Fluent) (Fluent)
1 0.0100 0.1322 0.1228 0.044
2 0.0092 0.1270 0.1240 0.043
3 0.0084 0.1216 0.1211 0.039
4 0.0068 0.1008 0.0984 0.036
5 0.005 0.0965 0.0960 0.032
6 0.0020 0.0605 0.060 0.027
Comparisons of post jump depth of experimental and fluent
value at Cd = 0.63
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0 0.002 0.004 0.006 0.008 0.01 0.012
Post jump Depth y2 m (experimental)
Post jump depth y2 m (Fluent)
Analysis of Pawana dam model
Table 5: Dimension of Pawana Dam
spillway model by Froude’s law (Scale 1 : 40)
Design Parameter Designation Prototype Model
Stilling Basin width B 12m 0.3m
Stilling Basin length L 60m 1.5m
Height of spillway H 25.3m 0.6325m
Height of crested weir h 4.36 0.109
Top width of crested
weir
b 2.95 0.074
Coefficient of discharge Cd 0.623 0.623
Crest height of weir Y’ 0.024
Hydraulic jump at discharge 0.0043 m3 /sec
Hydraulic jump at discharge 0.013 m3 /sec
Hydraulic jump at discharge 0.020 m3 /sec
Table 6 : Comparison of post jump depths for Pawana dam –
experimental and Fluent (designed weir)
Test Discharge Post jump Post jump Tail water
No. Q m3/s Depth Depth Depth
(Fluent) y2 m y2 m yt m
(Expt) (Fluent) (Expt)
1 0.0200 0.195 0.2070 0.054
2 0.0181 0.186 0.1922 0.052
3 0.0160 0.175 0.1846 0.049
4 0.0130 0.158 0.1640 0.045
5 0.0095 0.135 0.1455 0.04
6 0.0077 0.120 0.1260 0.037
7 0.0065 0.110 0.1204 0.035
8 0.0043 0.090 0.1002 0.03
Comparison of Experimental and Fluent – JHC (y 2) for Proposed
designed weir
0
0.05
0.1
0.15
0.2
0.25
0 0.005 0.01 0.015 0.02 0.025
JHC EXPERIMENTAL
JHC FLUENT
Conclusions
• The performance is checked for six discharges (20%, 50%, 68%, 84%, 92%
and 100% of the design discharge). It is found that for all these discharges
clear hydraulic jumps are formed and are located near toe of spillway.
• There was good correlation found between experimental values and fluent
values ranging between 0.9 to 0.98 .
• Among all the values of coefficient of discharge for design of weir Cd =
0.623 is found to be perfect.
Limitations
• The method developed in the study is
applicable for steady flow only.
• There are chances of cavitations in weir due to
too many rectangular sharp edges.
Unique Advantages of Proposed
Stilling Basin
1. As tail water level lies below the water level on apron,
the chances of horizontal eddies bringing the
sediments / riprap material back into the basin get
nullified.
2. The proposed stepped weir assures appropriate
location of jump for all operating conditions and thus
the corresponding Fr1 and energy dissipation is
maximum. This further reduces the chances of jump
sweep out in such situation.
3. The proposed basin requires no appurtenances like
chute blocks or baffle blocks. Thus there is saving in
their cost of construction.
References
• Achour, B., Debabeche, M. (2003). “Control of hydraulic
jump by sill in triangular channel”. J. Hydr. Res., 41(3), 319-
325.
• Anderson, J.D. (1995). “Computational fluid dynamics”.
McGraw-Hill book company, Inc., New York, 1995
• Chow, V.T. (1959). “Open channel hydraulics”. McGraw-Hill
book company, Inc., New York, 1959
• Hinge G. A., Balkrishna S., Khare K.C. (2010), Pawana Dam
Energy Dissipation – A Case Study, Australian Journal of
Basic and Applied Sciences, Vol.4(8), pp. 3261-3267.
• Hinge G. A., Balkrishna S., Khare K.C. (2010), Improved
Design of Stilling Basin for Deficient Tail Water, Journal of
Basic and Applied Scientific Research, Vol.1(1), pp. 31-40.
THANK YOU

Mais conteúdo relacionado

Mais procurados

Chapter 2 open channel hydraulics
Chapter 2 open channel hydraulicsChapter 2 open channel hydraulics
Chapter 2 open channel hydraulicsMohsin Siddique
 
Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11
Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11
Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11World University of Bangladesh
 
Rapidly varied flow
Rapidly varied flowRapidly varied flow
Rapidly varied flowMood Naik
 
Presentation on notches and weirs
Presentation on notches and weirsPresentation on notches and weirs
Presentation on notches and weirssush_vyas
 
Non equilibrium equation for unsteady radial flow
Non equilibrium equation for unsteady radial flowNon equilibrium equation for unsteady radial flow
Non equilibrium equation for unsteady radial flowAbhishek Gupta
 
Design of stilling basin and roughness devices
Design of stilling basin and roughness devices Design of stilling basin and roughness devices
Design of stilling basin and roughness devices Bilal Mirani
 
Hydrology (Estimation of peak flood discharge)
Hydrology (Estimation of peak flood discharge)Hydrology (Estimation of peak flood discharge)
Hydrology (Estimation of peak flood discharge)Latif Hyder Wadho
 
energy dissipator in hydraulic structure
energy dissipator  in  hydraulic structure energy dissipator  in  hydraulic structure
energy dissipator in hydraulic structure Kiran Jadhav
 
Design of Hydraulic Structures
Design of Hydraulic StructuresDesign of Hydraulic Structures
Design of Hydraulic StructuresGAURAV. H .TANDON
 
Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13
Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13
Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13World University of Bangladesh
 
(Part iii)- open channels
(Part iii)- open channels(Part iii)- open channels
(Part iii)- open channelsMohsin Siddique
 
S curve hydrograph
S curve hydrographS curve hydrograph
S curve hydrographSatish Taji
 
Uniform flow computations in open channel flow
Uniform flow computations in open channel flowUniform flow computations in open channel flow
Uniform flow computations in open channel flowASHWINIKUMAR359
 

Mais procurados (20)

design of weirs
design of weirsdesign of weirs
design of weirs
 
Chapter 2 open channel hydraulics
Chapter 2 open channel hydraulicsChapter 2 open channel hydraulics
Chapter 2 open channel hydraulics
 
HYDRAULIC JUMP
HYDRAULIC JUMPHYDRAULIC JUMP
HYDRAULIC JUMP
 
Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11
Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11
Class lectures on Hydrology by Rabindra Ranjan Saha Lecture 11
 
Rapidly varied flow
Rapidly varied flowRapidly varied flow
Rapidly varied flow
 
Hydraulic jump
Hydraulic jumpHydraulic jump
Hydraulic jump
 
Presentation on notches and weirs
Presentation on notches and weirsPresentation on notches and weirs
Presentation on notches and weirs
 
Non equilibrium equation for unsteady radial flow
Non equilibrium equation for unsteady radial flowNon equilibrium equation for unsteady radial flow
Non equilibrium equation for unsteady radial flow
 
Design of stilling basin and roughness devices
Design of stilling basin and roughness devices Design of stilling basin and roughness devices
Design of stilling basin and roughness devices
 
Hydrology (Estimation of peak flood discharge)
Hydrology (Estimation of peak flood discharge)Hydrology (Estimation of peak flood discharge)
Hydrology (Estimation of peak flood discharge)
 
energy dissipator in hydraulic structure
energy dissipator  in  hydraulic structure energy dissipator  in  hydraulic structure
energy dissipator in hydraulic structure
 
Chapter 7 gvf
Chapter 7 gvfChapter 7 gvf
Chapter 7 gvf
 
Weirs on Permeable Foundations
Weirs on Permeable FoundationsWeirs on Permeable Foundations
Weirs on Permeable Foundations
 
Design of Hydraulic Structures
Design of Hydraulic StructuresDesign of Hydraulic Structures
Design of Hydraulic Structures
 
Open Channel Flow
Open Channel FlowOpen Channel Flow
Open Channel Flow
 
Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13
Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13
Class lecture on Hydrology by Rabindra Ranjan saha Lecture 13
 
(Part iii)- open channels
(Part iii)- open channels(Part iii)- open channels
(Part iii)- open channels
 
Canal
CanalCanal
Canal
 
S curve hydrograph
S curve hydrographS curve hydrograph
S curve hydrograph
 
Uniform flow computations in open channel flow
Uniform flow computations in open channel flowUniform flow computations in open channel flow
Uniform flow computations in open channel flow
 

Semelhante a Hydraulic jump location control

Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...
Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...
Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...IRJET Journal
 
1 FLO-2D Updates and Enhancements 2019.pptx
1 FLO-2D Updates and Enhancements 2019.pptx1 FLO-2D Updates and Enhancements 2019.pptx
1 FLO-2D Updates and Enhancements 2019.pptxJorge Atau
 
Control Seepage Thought Earth Dams
Control Seepage Thought Earth DamsControl Seepage Thought Earth Dams
Control Seepage Thought Earth DamsAhmed Mansor
 
Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...
Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...
Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...IRJESJOURNAL
 
Deck drainage design
Deck drainage designDeck drainage design
Deck drainage designSarita Joshi
 
FLUID MECHANICS LAB MANUAL BSc Civil Technology 3rd Semster
FLUID  MECHANICS LAB  MANUAL BSc Civil Technology 3rd Semster FLUID  MECHANICS LAB  MANUAL BSc Civil Technology 3rd Semster
FLUID MECHANICS LAB MANUAL BSc Civil Technology 3rd Semster Bsc Civil Engineering Technology
 
Discharge Over a Vee-Notch Weir | Jameel Academy
Discharge Over a Vee-Notch Weir | Jameel AcademyDischarge Over a Vee-Notch Weir | Jameel Academy
Discharge Over a Vee-Notch Weir | Jameel AcademyJameel Academy
 
Critical flow through an Open channel
Critical flow through an Open channelCritical flow through an Open channel
Critical flow through an Open channelAjoy Kumar Saha
 
Odemba ECE2304 Hydraulics1Lab
Odemba ECE2304 Hydraulics1LabOdemba ECE2304 Hydraulics1Lab
Odemba ECE2304 Hydraulics1LabWalumasi Odemba
 
FLOW OVER A SHARP CRESTED WEIR
FLOW OVER A SHARP CRESTED WEIRFLOW OVER A SHARP CRESTED WEIR
FLOW OVER A SHARP CRESTED WEIRNazmul5492
 
Ce 3205-lecture-08-spillways
Ce 3205-lecture-08-spillwaysCe 3205-lecture-08-spillways
Ce 3205-lecture-08-spillwayssaibabu48
 
Basic Theory & Formulae Training Module
Basic Theory & Formulae Training ModuleBasic Theory & Formulae Training Module
Basic Theory & Formulae Training ModuleCookLegacyTraining
 
Answers assignment 5 open channel hydraulics-fluid mechanics
Answers assignment 5 open channel hydraulics-fluid mechanicsAnswers assignment 5 open channel hydraulics-fluid mechanics
Answers assignment 5 open channel hydraulics-fluid mechanicsasghar123456
 
13. Canal Outlets & other Head Regulators.pdf
13. Canal Outlets & other Head Regulators.pdf13. Canal Outlets & other Head Regulators.pdf
13. Canal Outlets & other Head Regulators.pdfMuhammadAjmal326519
 
Pump out tests in alluvial sands – a case study
Pump out tests in alluvial sands – a case studyPump out tests in alluvial sands – a case study
Pump out tests in alluvial sands – a case studyInfocengrs63
 

Semelhante a Hydraulic jump location control (20)

Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...
Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...
Restricting Hydraulic Jump Location Inside Stilling Basin for Maximum Energy ...
 
1 FLO-2D Updates and Enhancements 2019.pptx
1 FLO-2D Updates and Enhancements 2019.pptx1 FLO-2D Updates and Enhancements 2019.pptx
1 FLO-2D Updates and Enhancements 2019.pptx
 
Control Seepage Thought Earth Dams
Control Seepage Thought Earth DamsControl Seepage Thought Earth Dams
Control Seepage Thought Earth Dams
 
Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...
Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...
Energy Dissipation Regimes and Stability of the Overflow Dam (Spillway) for t...
 
Teoria bocatoma
Teoria bocatomaTeoria bocatoma
Teoria bocatoma
 
Deck drainage design
Deck drainage designDeck drainage design
Deck drainage design
 
FLUID MECHANICS LAB MANUAL BSc Civil Technology 3rd Semster
FLUID  MECHANICS LAB  MANUAL BSc Civil Technology 3rd Semster FLUID  MECHANICS LAB  MANUAL BSc Civil Technology 3rd Semster
FLUID MECHANICS LAB MANUAL BSc Civil Technology 3rd Semster
 
Discharge Over a Vee-Notch Weir | Jameel Academy
Discharge Over a Vee-Notch Weir | Jameel AcademyDischarge Over a Vee-Notch Weir | Jameel Academy
Discharge Over a Vee-Notch Weir | Jameel Academy
 
wk1_Introduction.pdf
wk1_Introduction.pdfwk1_Introduction.pdf
wk1_Introduction.pdf
 
Culvertdesign
CulvertdesignCulvertdesign
Culvertdesign
 
Critical flow through an Open channel
Critical flow through an Open channelCritical flow through an Open channel
Critical flow through an Open channel
 
Odemba ECE2304 Hydraulics1Lab
Odemba ECE2304 Hydraulics1LabOdemba ECE2304 Hydraulics1Lab
Odemba ECE2304 Hydraulics1Lab
 
FLOW OVER A SHARP CRESTED WEIR
FLOW OVER A SHARP CRESTED WEIRFLOW OVER A SHARP CRESTED WEIR
FLOW OVER A SHARP CRESTED WEIR
 
Ce 3205-lecture-08-spillways
Ce 3205-lecture-08-spillwaysCe 3205-lecture-08-spillways
Ce 3205-lecture-08-spillways
 
Basic Theory & Formulae Training Module
Basic Theory & Formulae Training ModuleBasic Theory & Formulae Training Module
Basic Theory & Formulae Training Module
 
Surface runoff
Surface runoffSurface runoff
Surface runoff
 
Answers assignment 5 open channel hydraulics-fluid mechanics
Answers assignment 5 open channel hydraulics-fluid mechanicsAnswers assignment 5 open channel hydraulics-fluid mechanics
Answers assignment 5 open channel hydraulics-fluid mechanics
 
13. Canal Outlets & other Head Regulators.pdf
13. Canal Outlets & other Head Regulators.pdf13. Canal Outlets & other Head Regulators.pdf
13. Canal Outlets & other Head Regulators.pdf
 
Hydrology.pdf
Hydrology.pdfHydrology.pdf
Hydrology.pdf
 
Pump out tests in alluvial sands – a case study
Pump out tests in alluvial sands – a case studyPump out tests in alluvial sands – a case study
Pump out tests in alluvial sands – a case study
 

Último

VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Christo Ananth
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptDineshKumar4165
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfRagavanV2
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdfankushspencer015
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VDineshKumar4165
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSISrknatarajan
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingrknatarajan
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdfSuman Jyoti
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...roncy bisnoi
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756dollysharma2066
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 

Último (20)

VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 

Hydraulic jump location control

  • 1. CONTROLLING THE LOCATION OF HYDRAULIC JUMP IN RECTANGULAR CHANNEL SUBMITTED BY SUBMITTED TO SIDDHARTH UPADHYAY Mr. S ANBU KUMAR 2K15/HFE/15 ASSOCIATE PROFESSOR Department of Civil Engineering
  • 2. INTRODUCTION • Statistics and studies made by International Commission on Large Dams (ICOLD) show that more than 20% of dam accidents occurred due to poor provision of energy dissipation arrangements. • Normally energy dissipators are designed for ‘design discharge’ of spillway. But their performance is affected during varying discharge condition. • In majority of failure cases, the jump is not clear – i.e. jump is either swept up or drowned. • Our present study objective is to design a suitable design of hydraulic jump type energy dissipator for tail water deficiency and steady flow. This can largely reduce dependency on TWRC without disconnecting it from JHC. • Efforts are made to produce required JHC at all discharges to form clear jumps.
  • 3. Damaged stilling basin of sardar sarovar dam
  • 4. • Sardar Sarovar Project (SSP) is one of the major projects in India. In the year 1999 it is reported that during a flood in monsoon season, 10,000 m3 of concrete was washed out due to flood flows. • The design discharge of spillway is 87,000m3/s. The flood was even lesser than 50% of the design discharge. • The approximate cost of concrete that washed out was Rs. 3 crore
  • 5. View of dislodged panel at Bhama askhed dam
  • 6. Definition sketch of hydraulic jump
  • 7. Design of rectangular stepped weir (Section A-A earlier shown)
  • 8. FORMULA USED FOR DETERMINATION OF DIMENSION OF STEPPED WEIR
  • 9. Classification of tail water conditions for the design of energy dissipator
  • 10. FACTORS AFFECTING HYDRAULIC JUMP Factors affecting hydraulic jump are • Total head on upstream of sluice gate (H), • Pre jump depth (y1) , • Post jump depth (y2), • Crest height of weir (y'), • Head over weir crest (h) and tail water depth (yt). • Another non dimensional important parameter that governs hydraulic jump phenomenon is supercritical Froude number Fr1.
  • 11. Dimensions and Data of model used in fluent Height of sluice gate H=0.4m, Height of flume H’=0.45m Width of flume B=0.3m, Length of flume L=4m Max discharge Qmax=0.01 m3/s, Min discharge Qmin=0.002 m3/s, Crest height of weir y'=0.015m
  • 12.
  • 13. Table 1: Output of Mathematical Procedure for Data (Horizontal apron and Cd = 0.623) Sr. No. Q y1 y2 H Fr1 B m3/s M M M M 1 0.0020 0.0024 0.0605 0.0455 18.3350 0.1119 2 0.0028 0.0033 0.0714 0.0564 15.4960 0.1336 3 0.0036 0.0043 0.0807 0.0657 13.6661 0.1463 4 0.0044 0.0052 0.0889 0.0739 12.3614 0.1569 5 0.005 0.0062 0.0965 0.0814 11.3709 0.1660 6 0.0060 0.0071 0.1034 0.0884 10.5857 0.1741 7 0.0068 0.0081 0.1098 0.0948 9.9435 0.1816 8 0.0076 0.0090 0.1159 0.1009 9.4056 0.1884 9 0.0084 0.0100 0.1216 0.1066 8.9466 0.1949 10 0.0092 0.010947 0.1270 0.1120 8.5487 0.2010 11 0.0100 0.011899 0.1322 0.1172 8.1997 0.2067
  • 14. Stepped weir in fluent
  • 15. Stepped weir in fluent
  • 19. Hydraulic jump at discharge 0.0020 m3 /sec
  • 20. Hydraulic jump at discharge 0.005 m3 /sec
  • 21. Hydraulic jump at discharge 0.0068 m3 /sec
  • 22. Hydraulic jump at discharge 0.0084 m3 /sec
  • 23. Hydraulic jump at discharge 0.0092 m3 /sec
  • 24. Hydraulic jump at discharge 0.010 m3 /sec
  • 25. Table 2: Comparisons of post jump depth of experimental and fluent value at Cd = 0.60 Test Discharge Post jump Post jump Tail water No. Q m3/s Depth Depth depth y2 m y2 m yt m (Fluent) (experimental) (Fluent) (Fluent) 1 0.0100 0.132 0.1210 0.063 2 0.0092 0.1270 0.1161 0.059 3 0.0084 0.1216 0.1089 0.056 4 0.0068 0.1098 0.1040 0.049 5 0.0050 0.0968 0.0913 0.041 6 0.0040 0.0865 0.0869 0.035 7 0.0020 0.0605 0.0621 0.028
  • 26. Comparisons of post jump depth of experimental and fluent value at Cd = 0.60 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0 0.002 0.004 0.006 0.008 0.01 0.012 y2 Discharge (m3/s) JHC Exp. JHC fluent
  • 27. Table 3: Comparisons of post jump depth of experimental and fluent value at Cd = 0.65 Test Discharge Post jump Post jump Tail water No. Q m3/s Depth depth Depth y2 m y2 m yt m (Fluent) (Experimental) (Fluent) (Fluent) 1 0.0100 0.1322 0.1140 0.0540 2 0.0092 0.1270 0.1110 0.0510 3 0.0084 0.1216 0.1035 0.0475 4 0.0068 0.1098 0.1010 0.0464 5 0.0050 0.0965 0.0850 0.0363 6 0.0040 0.0850 0.0810 0.0330 7 0.0020 0.0605 0.0587 0.0270
  • 28. Comparison of Experimental and Fluent – JHC (y 2) at for horizontal apron (Cd = 0.65) 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0 0.002 0.004 0.006 0.008 0.01 0.012 Post jump Depth y2 m (Experimental) Post jump depth y2 m (Fluent)
  • 29. Table 4 : Comparisons of post jump depth of experimental and fluent value at Cd = 0.63 Test Discharge Post jump Post jump Tail water No. Q m3/s Depth depth Depth y2 m y2 m yt m (Fluent) (Experimental) (Fluent) (Fluent) 1 0.0100 0.1322 0.1228 0.044 2 0.0092 0.1270 0.1240 0.043 3 0.0084 0.1216 0.1211 0.039 4 0.0068 0.1008 0.0984 0.036 5 0.005 0.0965 0.0960 0.032 6 0.0020 0.0605 0.060 0.027
  • 30. Comparisons of post jump depth of experimental and fluent value at Cd = 0.63 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0 0.002 0.004 0.006 0.008 0.01 0.012 Post jump Depth y2 m (experimental) Post jump depth y2 m (Fluent)
  • 31. Analysis of Pawana dam model
  • 32. Table 5: Dimension of Pawana Dam spillway model by Froude’s law (Scale 1 : 40) Design Parameter Designation Prototype Model Stilling Basin width B 12m 0.3m Stilling Basin length L 60m 1.5m Height of spillway H 25.3m 0.6325m Height of crested weir h 4.36 0.109 Top width of crested weir b 2.95 0.074 Coefficient of discharge Cd 0.623 0.623 Crest height of weir Y’ 0.024
  • 33. Hydraulic jump at discharge 0.0043 m3 /sec
  • 34. Hydraulic jump at discharge 0.013 m3 /sec
  • 35. Hydraulic jump at discharge 0.020 m3 /sec
  • 36. Table 6 : Comparison of post jump depths for Pawana dam – experimental and Fluent (designed weir) Test Discharge Post jump Post jump Tail water No. Q m3/s Depth Depth Depth (Fluent) y2 m y2 m yt m (Expt) (Fluent) (Expt) 1 0.0200 0.195 0.2070 0.054 2 0.0181 0.186 0.1922 0.052 3 0.0160 0.175 0.1846 0.049 4 0.0130 0.158 0.1640 0.045 5 0.0095 0.135 0.1455 0.04 6 0.0077 0.120 0.1260 0.037 7 0.0065 0.110 0.1204 0.035 8 0.0043 0.090 0.1002 0.03
  • 37. Comparison of Experimental and Fluent – JHC (y 2) for Proposed designed weir 0 0.05 0.1 0.15 0.2 0.25 0 0.005 0.01 0.015 0.02 0.025 JHC EXPERIMENTAL JHC FLUENT
  • 38. Conclusions • The performance is checked for six discharges (20%, 50%, 68%, 84%, 92% and 100% of the design discharge). It is found that for all these discharges clear hydraulic jumps are formed and are located near toe of spillway. • There was good correlation found between experimental values and fluent values ranging between 0.9 to 0.98 . • Among all the values of coefficient of discharge for design of weir Cd = 0.623 is found to be perfect.
  • 39. Limitations • The method developed in the study is applicable for steady flow only. • There are chances of cavitations in weir due to too many rectangular sharp edges.
  • 40. Unique Advantages of Proposed Stilling Basin 1. As tail water level lies below the water level on apron, the chances of horizontal eddies bringing the sediments / riprap material back into the basin get nullified. 2. The proposed stepped weir assures appropriate location of jump for all operating conditions and thus the corresponding Fr1 and energy dissipation is maximum. This further reduces the chances of jump sweep out in such situation. 3. The proposed basin requires no appurtenances like chute blocks or baffle blocks. Thus there is saving in their cost of construction.
  • 41. References • Achour, B., Debabeche, M. (2003). “Control of hydraulic jump by sill in triangular channel”. J. Hydr. Res., 41(3), 319- 325. • Anderson, J.D. (1995). “Computational fluid dynamics”. McGraw-Hill book company, Inc., New York, 1995 • Chow, V.T. (1959). “Open channel hydraulics”. McGraw-Hill book company, Inc., New York, 1959 • Hinge G. A., Balkrishna S., Khare K.C. (2010), Pawana Dam Energy Dissipation – A Case Study, Australian Journal of Basic and Applied Sciences, Vol.4(8), pp. 3261-3267. • Hinge G. A., Balkrishna S., Khare K.C. (2010), Improved Design of Stilling Basin for Deficient Tail Water, Journal of Basic and Applied Scientific Research, Vol.1(1), pp. 31-40.