SlideShare uma empresa Scribd logo
1 de 29
www.heatflux.com
Improving Performance of Coker Heaters
Ashutosh Garg
Furnace Improvements
Sugar Land, TX
www.heatflux.com
Coker Heaters
 Most critical heaters in the refineries
 Objective: Heavy feedstock is converted to higher value products, such as
gasoline, diesel fuel, LPG, and petroleum coke
 Delayed coking is an endothermic reaction with the heater supplying heat
 Coking in Tubes:
 Pressure drop goes up
 Tube metal temperatures go up
 The rate of coke deposition determine Coker heater run length
 Coke removal by steam spalling/pigging (1-4 days lost)
 Any shutdown for coke removal causes production loss
2
www.heatflux.com
Coker Heater Typical Design Parameters
 Inlet temperature
 500-600°F
 Outlet temperature
 900-950°F
 Coil Pressure Drop
 350-450 Psi (EOR)
 Condensate Flow Rate
 0.5–1% of heater feed
 Average Heat Flux
 < 10,000 Btu/hr.ft2 (Single
Fired)
 Mass velocity
 350-550 lb/sec.ft2
 Cold oil velocity
 around 6-10 ft/s
3
www.heatflux.com
Coker Heater
4
 Twin Cell Box Type Heater
 Natural Draft Operation
 Horizontal Tube Arrangement
 Central Bridgewall
 Gas fired floor mounted Burners
 Process, SSH and SG Coils in
Convection Section
 Self- supported stack on top of
Convection Section
Existing Coker Heater
PROCESS COIL
4 BARE ROWS
SG COIL
7 FINNED ROWS
SSH COIL
2 FINNED TUBES
PROCESS COIL
7 FINNED ROWS
#1 #2
CELL-1 CELL-2
#1
#1
#2
#2
#4
#4#3
www.heatflux.com
Existing Coker Radiant Section
5
www.heatflux.com
Stack
Flue Gas Offtake Ducts
Convection Section
Platforms
Radiant Header Boxes (New)
Radiant Arch (New)
Coker Heater
(Isometric View)
6
www.heatflux.com
Coker Heater Operating Issues
Coking
 Frequent decoking requirement (every year)
 Short tube life around 5-6 years
Overheating and flame impingement on roof tubes
 Longer flame lengths
 Low roof tubes elevation
 Firing Imbalance
 Higher firing in outer cells by almost 30%
7
www.heatflux.com
Existing Geometry for CFD
8
Burner 1 Burner 2
Cell 1
Zone 1 Zone 2
Inner cell
tubes
Outer cell tubes
No. of burners in
CFD model: 6
Design heat release
per burner: 3.0
MMBtu/hr
www.heatflux.com
Flue Gas Flow and Temperature Profile
9
 Higher
velocity flue
gas is
observed on
the inner side
 Higher flue
gas
temperature
observed near
the inner cell
tubes
Existing Design
[°F]
[ft/s]
www.heatflux.com
Radiant Heat Flux Profile
10
 Radiant heat flux for
inner cell tubes is
higher as compared to
the outer cell tubes
Existing Design
Inner Tubes Outer Tubes
[Btu/hr.ft2]
www.heatflux.com
Flue Gas Temperature around Tubes
11
[°F]
Inner Tubes Outer Tubes
 Flue gas temperatures around
inner cell tubes and outer cell
tubes are significantly
different
Existing Design
www.heatflux.com
[°F]
Flue Gas Flow and Temperature Profile
12
 High flue gas temperature and
velocity is reduced for the inner
tubes
Existing Operating[ft/s]
www.heatflux.com
Radiant Heat Flux
13
Inner Tubes Outer Tubes
 Radiant heat flux is
similar for inner and
outer tubes for
operating case
Existing Operating
[Btu/hr.ft2]
www.heatflux.com
Flue Gas Temperature around Tubes
Inner Tubes
Existing Operating
[°F]
Outer Tubes
 Clearly, the difference in
flue gas temperatures around
inner and outer cell tubes
have reduced significantly as
compared to the design case
 This reduction is because
inner cells were fired at 30%
lower firing rate than outer
cells
14
www.heatflux.com
Design = 12 Psi
Average = 17.58 Psi
10
13
16
18
21
24
15-May-14 8-Jan-15 2-Sep-15 26-Apr-16 19-Dec-16 14-Aug-17
Pressure,(Psi)
TIME
Fuel Gas Pressure
15
West Outer Cell West Center Cell
Design = 12 Psi
Average = 12.45 Psi
6
9
12
14
17
20
15-May-14 8-Jan-15 2-Sep-15 26-Apr-16 19-Dec-16 14-Aug-17
Pressure,(Psi)
TIME
Fuel gas pressure in outer cell is almost 40% higher than the fuel gas
pressure in inner cells
www.heatflux.com
1
(Pass
inlet)
5
10
31
(Pass
outlet)
800
810
820
830
840
850
860
870
880
890
900
1 2 3 4 5 6 7 8 9 10 11-15
TubeMetalTemperature,ºF
Tube No(s).
Operating: Inner Tubes
Operating: Outer Tubes
0.6°F
1.5°F
4.2°F
5.2°F
4.8°F
5.8°F
6.8°F
6.8°F
7.6°F
5.6°F
7.5°F
800
810
820
830
840
850
860
870
880
890
900
1 2 3 4 5 6 7 8 9 10 11-15
TubeMetalTemperature,ºF
Tube No(s).
Design: Inner Tubes
Design: Outer Tubes2.9°F
7.7°F
13.4°F
15.7°F
17.9°F
16.9°F
17.1°F
15.3°F
16.8°F
14.5°F
16.4°F
TMT Comparison with Existing Design
TMT difference between the inner and outer tubes has decreased
for each of the tubes for the operating case where inner cell
burners fire 30% lower than the outer cell burners
Existing Design Existing Operating
www.heatflux.com
Flue Gas Temperature Profile
17
Operating Case
For operating case flue
gas temperature in the
inner cell has reduced
[°F]
Design Case
www.heatflux.com
Radiant Heat Flux Profile
18
Design Case Operating Case
Radiant tubes heat flux
for inner tubes has
been reduced for the
operating case
[Btu/hr.ft2]
www.heatflux.com
Radiant Re-Tubing Proposed Options
(Design TMTs)
19
The design tube metal temperature comparison for existing and proposed
options at design pressure of 215 psig:
Case Tube Details Material
Design
TMT, °F
Limiting
Design Metal
Temp, °F
Existing 3.5” NPS Sch 80 9 Cr-1Mo 1,240
1,300
Proposed Option-1
4” OD, 0.4” MWT
9 Cr-1Mo 1,285
Proposed Option-2 SS347H 1,500 1,500
Proposed Option-3
(Finalized Option)
4.25” OD, 0.5”
MWT
9 Cr-1Mo 1,300 1,300
www.heatflux.com
Radiant Coil Re-Tubing
 No. of radiant tubes: 62 per box
 Tube size: 4” OD, Sch 80
 Heat transfer area: 7,770 ft2
 Tube material: 9 Cr
 Coker Mass Velocity-295 lbs/s ft2
 Pressure drop-210 psi
 Total radiant tubes: 66 per box
 Addition of 4 new radiant tubes
 2 tubes installed at outlet and 2
at roof
 Tube size: 4.25” OD, 0.5” MWT
 Heat transfer area: 8,880 ft2
 Tube material: 9 Cr
 Coker Mass Velocity-347 lbs/s ft2
 Pressure Drop- 242 psi
20
Existing Design Proposed Design
Radiant heat transfer area increased by 15% in the heater
www.heatflux.com
Revamped Heater Radiant Section
21
www.heatflux.com
Existing & Proposed Design
of Radiant Section
22
New Radiant Tubes
(Each Cell)
New Radiant Tubes
(Each Cell)
ProposedExisting
CELL-1 CELL-2
#1
#1
#2
#2
#4
#4#3
#1 #2 #4#3
CELL-1 CELL-2
www.heatflux.com
Velocity Vectors
 Flue gas velocity near inner
tubes is very high and getting
deflected downward
 Flue gas velocity is shifted
downward with addition of baffle
 Roof tubes are away from flue gas
Adding refractory baffle at the top further improves the flue gas recirculation pattern
Existing Proposed Case with
Baffle
Proposed Case
[ft/s]
www.heatflux.com
Flue Gas Temperature Contours
Addition of refractory baffle further increased the distance of hot flue gas with
respect to roof tubes
 High temperature flue gas is
touching the inner roof tubes
 Shifting roof tubes reduces chances of
flame impingement / coking issues
24
[°F]
Existing Proposed Case with
Baffle
Proposed Case
www.heatflux.com
Radiant Tube Heat Flux (Arch)
Maximum heat flux on roof tubes is reduced by ~4,200 Btu/hr.ft2
Proposed Case
Heat Flux 18,651 Btu/hr.ft2 Heat Flux 14,443 Btu/hr.ft2
Existing
25
[Btu/hr.ft2]
www.heatflux.com
5,000
9,000
13,000
17,000
21,000
25,000
0 5 10 15 20 25 30
RadiantHeatFlux,Btu/hr-ft2
Radiant Tube No.
Comparison of Radiant Heat Flux
Existing
Proposed Case
Roof
Tubes
Wall
Tubes
Tube wise comparison of heat flux shows considerable reduction for roof tubes
Radiant Heat Flux – Inner Tubes
26
www.heatflux.com
Existing vs Proposed Design
Parameters Units Existing Proposed
Total Heat Duty MMBtu/hr 125.1 126.8
Process Heat Duty MMBtu/hr 112.1 114.2
Charge Flow Rate lb/hr 263,000 326,953
Outlet Temperature °F 950 935
Bridge Wall Temperature °F 1,620 1,552
Radiant Heat Duty MMBtu/hr 77.7 79.3
Radiant Heat Transfer Area ft2 7,770 8,880
Average / Maximum Radiant Heat Flux Btu/hr/ft2 10,000 / 17,000 8,932 / 15,184
Fluid Mass Velocity in Radiant Section lb/sec/ft2 295.9 431.0
27
www.heatflux.com
Future Revamping
 The convection section needs upgrading. Feed outlet
temperature from convection section is 650-660F as
compared to design of 710F.
 The flue gas temperature approach to the coker feed is
around 250-300 F and can be reduced significantly.
 Convection upgrade will substantially help the coker heater
further.
 Future revamping window opens up around 2026
28
www.heatflux.com
Thank you very much
 Questions and Comments are Welcome
29
Travel Tip- Download “ Gypsy Guide for Hawaii” on your cell phone and start driving.

Mais conteúdo relacionado

Mais procurados

Heater operation
Heater operationHeater operation
Heater operationJOMON M.C
 
Catalyst Catastrophes in Syngas Production - II
Catalyst Catastrophes in Syngas Production - IICatalyst Catastrophes in Syngas Production - II
Catalyst Catastrophes in Syngas Production - IIGerard B. Hawkins
 
Pre-reformer Operations Technical Supplement
Pre-reformer Operations Technical SupplementPre-reformer Operations Technical Supplement
Pre-reformer Operations Technical SupplementGerard B. Hawkins
 
AIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGERAIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGERAhsan Shakil
 
A new approach to improving heater efficiency
A new approach to improving heater efficiencyA new approach to improving heater efficiency
A new approach to improving heater efficiencyAshutosh Garg
 
Primary Reforming Flowsheets
Primary Reforming FlowsheetsPrimary Reforming Flowsheets
Primary Reforming FlowsheetsGerard B. Hawkins
 
Feedstock Purificatiion in Hydrogen Plants
Feedstock Purificatiion in Hydrogen PlantsFeedstock Purificatiion in Hydrogen Plants
Feedstock Purificatiion in Hydrogen PlantsGerard B. Hawkins
 
Burner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia PlantsBurner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia PlantsGerard B. Hawkins
 
Theory and Practice of Steam Reforming
Theory and Practice of Steam ReformingTheory and Practice of Steam Reforming
Theory and Practice of Steam ReformingGerard B. Hawkins
 
Reduction and Start-Up of Steam Reforming Catalyst
Reduction and Start-Up of Steam Reforming CatalystReduction and Start-Up of Steam Reforming Catalyst
Reduction and Start-Up of Steam Reforming CatalystGerard B. Hawkins
 
Fired Heater Efficiency Guide
Fired Heater Efficiency GuideFired Heater Efficiency Guide
Fired Heater Efficiency Guidejustinforth
 
An introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdfAn introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdfKarnav Rana
 
Steam Reforming - Common Problems
Steam Reforming - Common ProblemsSteam Reforming - Common Problems
Steam Reforming - Common ProblemsGerard B. Hawkins
 
Normal Operation of Steam Reformers on Hydrogen Plants
Normal Operation of Steam Reformers on Hydrogen PlantsNormal Operation of Steam Reformers on Hydrogen Plants
Normal Operation of Steam Reformers on Hydrogen PlantsGerard B. Hawkins
 
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...Pradeep Dhondi
 
A presentation on reformer new
A presentation on reformer newA presentation on reformer new
A presentation on reformer newGowri Shankar
 

Mais procurados (20)

Heater operation
Heater operationHeater operation
Heater operation
 
Catalyst Catastrophes in Syngas Production - II
Catalyst Catastrophes in Syngas Production - IICatalyst Catastrophes in Syngas Production - II
Catalyst Catastrophes in Syngas Production - II
 
Pre-reformer Operations Technical Supplement
Pre-reformer Operations Technical SupplementPre-reformer Operations Technical Supplement
Pre-reformer Operations Technical Supplement
 
AIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGERAIR COOLED HEAT EXCHANGER
AIR COOLED HEAT EXCHANGER
 
A new approach to improving heater efficiency
A new approach to improving heater efficiencyA new approach to improving heater efficiency
A new approach to improving heater efficiency
 
FIRED HEATERS .ppt
FIRED HEATERS .pptFIRED HEATERS .ppt
FIRED HEATERS .ppt
 
Primary Reforming Flowsheets
Primary Reforming FlowsheetsPrimary Reforming Flowsheets
Primary Reforming Flowsheets
 
Feedstock Purificatiion in Hydrogen Plants
Feedstock Purificatiion in Hydrogen PlantsFeedstock Purificatiion in Hydrogen Plants
Feedstock Purificatiion in Hydrogen Plants
 
Steam Reforming - Poisons
Steam Reforming - PoisonsSteam Reforming - Poisons
Steam Reforming - Poisons
 
Burner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia PlantsBurner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia Plants
 
flare system design.pdf
flare system design.pdfflare system design.pdf
flare system design.pdf
 
Efficient Steam Systems -
Efficient Steam Systems -Efficient Steam Systems -
Efficient Steam Systems -
 
Theory and Practice of Steam Reforming
Theory and Practice of Steam ReformingTheory and Practice of Steam Reforming
Theory and Practice of Steam Reforming
 
Reduction and Start-Up of Steam Reforming Catalyst
Reduction and Start-Up of Steam Reforming CatalystReduction and Start-Up of Steam Reforming Catalyst
Reduction and Start-Up of Steam Reforming Catalyst
 
Fired Heater Efficiency Guide
Fired Heater Efficiency GuideFired Heater Efficiency Guide
Fired Heater Efficiency Guide
 
An introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdfAn introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdf
 
Steam Reforming - Common Problems
Steam Reforming - Common ProblemsSteam Reforming - Common Problems
Steam Reforming - Common Problems
 
Normal Operation of Steam Reformers on Hydrogen Plants
Normal Operation of Steam Reformers on Hydrogen PlantsNormal Operation of Steam Reformers on Hydrogen Plants
Normal Operation of Steam Reformers on Hydrogen Plants
 
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
Design Calculations of Venting in Atmospheric and Low-pressure Storage Tanks ...
 
A presentation on reformer new
A presentation on reformer newA presentation on reformer new
A presentation on reformer new
 

Semelhante a Improving Performance of Coker Heaters

Improving Shale Oil Crude Heater Performance- India 2018
Improving Shale Oil Crude Heater  Performance- India 2018Improving Shale Oil Crude Heater  Performance- India 2018
Improving Shale Oil Crude Heater Performance- India 2018Abhinanda Das
 
Improve shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshareImprove shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshareAshutosh Garg
 
Improve Shale Oil Crude Heater Performance
Improve Shale Oil Crude Heater PerformanceImprove Shale Oil Crude Heater Performance
Improve Shale Oil Crude Heater PerformanceAditya Shah
 
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2AIChE 2018 improving catalytic reformer heaters using split flow technology rev2
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2Ashutosh Garg
 
Summary of changes in burner specifications
Summary of changes in burner specificationsSummary of changes in burner specifications
Summary of changes in burner specificationsKapil Batra
 
Greenhouse Heating
Greenhouse HeatingGreenhouse Heating
Greenhouse Heatingbuddy.tignor
 
Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...
Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...
Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...ATMOsphere Conferences & Events
 
Steam Reforming - Practical Operations
Steam Reforming - Practical OperationsSteam Reforming - Practical Operations
Steam Reforming - Practical OperationsGerard B. Hawkins
 
All about boilers: Complete Basics, Classification of boilers,types
All about boilers: Complete Basics, Classification of boilers,typesAll about boilers: Complete Basics, Classification of boilers,types
All about boilers: Complete Basics, Classification of boilers,typesHashim Hasnain Hadi
 
Construction of 500 MW Steam Boiler
Construction of 500 MW Steam BoilerConstruction of 500 MW Steam Boiler
Construction of 500 MW Steam BoilerVaibhav Paydelwar
 
Reservoir Heat Requirement During a Steamflood Exhibiting Steam Override
Reservoir Heat Requirement During a Steamflood Exhibiting Steam OverrideReservoir Heat Requirement During a Steamflood Exhibiting Steam Override
Reservoir Heat Requirement During a Steamflood Exhibiting Steam OverrideLong Vo
 
BOILER PRESENTATION ON 21.10.14 1.pdf
BOILER PRESENTATION ON 21.10.14 1.pdfBOILER PRESENTATION ON 21.10.14 1.pdf
BOILER PRESENTATION ON 21.10.14 1.pdfPrasadKandukuri4
 
3. remote cooling applications
3. remote cooling applications3. remote cooling applications
3. remote cooling applicationsBarış Çoban
 
Methane Steam Reformer Re-tube Studies
Methane Steam Reformer Re-tube StudiesMethane Steam Reformer Re-tube Studies
Methane Steam Reformer Re-tube StudiesGerard B. Hawkins
 
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and PetrochemicalsFired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and PetrochemicalsAshutosh Garg
 
Heat optimisation pradeep kumar
Heat optimisation  pradeep kumarHeat optimisation  pradeep kumar
Heat optimisation pradeep kumarpradeepdeepi
 

Semelhante a Improving Performance of Coker Heaters (20)

Improving Shale Oil Crude Heater Performance- India 2018
Improving Shale Oil Crude Heater  Performance- India 2018Improving Shale Oil Crude Heater  Performance- India 2018
Improving Shale Oil Crude Heater Performance- India 2018
 
Improve shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshareImprove shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshare
 
Improve Shale Oil Crude Heater Performance
Improve Shale Oil Crude Heater PerformanceImprove Shale Oil Crude Heater Performance
Improve Shale Oil Crude Heater Performance
 
Methanol Reformer Designs
Methanol Reformer DesignsMethanol Reformer Designs
Methanol Reformer Designs
 
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2AIChE 2018 improving catalytic reformer heaters using split flow technology rev2
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2
 
Summary of changes in burner specifications
Summary of changes in burner specificationsSummary of changes in burner specifications
Summary of changes in burner specifications
 
Greenhouse Heating
Greenhouse HeatingGreenhouse Heating
Greenhouse Heating
 
Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...
Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...
Optimisation of transcritical R744 gas coolers with Microgroove smaller diame...
 
draft.pdf
draft.pdfdraft.pdf
draft.pdf
 
Steam Reforming - Practical Operations
Steam Reforming - Practical OperationsSteam Reforming - Practical Operations
Steam Reforming - Practical Operations
 
All about boilers: Complete Basics, Classification of boilers,types
All about boilers: Complete Basics, Classification of boilers,typesAll about boilers: Complete Basics, Classification of boilers,types
All about boilers: Complete Basics, Classification of boilers,types
 
Construction of 500 MW Steam Boiler
Construction of 500 MW Steam BoilerConstruction of 500 MW Steam Boiler
Construction of 500 MW Steam Boiler
 
Reservoir Heat Requirement During a Steamflood Exhibiting Steam Override
Reservoir Heat Requirement During a Steamflood Exhibiting Steam OverrideReservoir Heat Requirement During a Steamflood Exhibiting Steam Override
Reservoir Heat Requirement During a Steamflood Exhibiting Steam Override
 
mechanical engineering design.ppt
mechanical engineering design.pptmechanical engineering design.ppt
mechanical engineering design.ppt
 
BOILER PRESENTATION ON 21.10.14 1.pdf
BOILER PRESENTATION ON 21.10.14 1.pdfBOILER PRESENTATION ON 21.10.14 1.pdf
BOILER PRESENTATION ON 21.10.14 1.pdf
 
3. remote cooling applications
3. remote cooling applications3. remote cooling applications
3. remote cooling applications
 
Methane Steam Reformer Re-tube Studies
Methane Steam Reformer Re-tube StudiesMethane Steam Reformer Re-tube Studies
Methane Steam Reformer Re-tube Studies
 
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and PetrochemicalsFired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
 
36512435-Fired-Heater-Design.ppt
36512435-Fired-Heater-Design.ppt36512435-Fired-Heater-Design.ppt
36512435-Fired-Heater-Design.ppt
 
Heat optimisation pradeep kumar
Heat optimisation  pradeep kumarHeat optimisation  pradeep kumar
Heat optimisation pradeep kumar
 

Último

Online banking management system project.pdf
Online banking management system project.pdfOnline banking management system project.pdf
Online banking management system project.pdfKamal Acharya
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdfSuman Jyoti
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTbhaskargani46
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfRagavanV2
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...SUHANI PANDEY
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesPrabhanshu Chaturvedi
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingrknatarajan
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756dollysharma2066
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...ranjana rawat
 

Último (20)

Online banking management system project.pdf
Online banking management system project.pdfOnline banking management system project.pdf
Online banking management system project.pdf
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 

Improving Performance of Coker Heaters

  • 1. www.heatflux.com Improving Performance of Coker Heaters Ashutosh Garg Furnace Improvements Sugar Land, TX
  • 2. www.heatflux.com Coker Heaters  Most critical heaters in the refineries  Objective: Heavy feedstock is converted to higher value products, such as gasoline, diesel fuel, LPG, and petroleum coke  Delayed coking is an endothermic reaction with the heater supplying heat  Coking in Tubes:  Pressure drop goes up  Tube metal temperatures go up  The rate of coke deposition determine Coker heater run length  Coke removal by steam spalling/pigging (1-4 days lost)  Any shutdown for coke removal causes production loss 2
  • 3. www.heatflux.com Coker Heater Typical Design Parameters  Inlet temperature  500-600°F  Outlet temperature  900-950°F  Coil Pressure Drop  350-450 Psi (EOR)  Condensate Flow Rate  0.5–1% of heater feed  Average Heat Flux  < 10,000 Btu/hr.ft2 (Single Fired)  Mass velocity  350-550 lb/sec.ft2  Cold oil velocity  around 6-10 ft/s 3
  • 4. www.heatflux.com Coker Heater 4  Twin Cell Box Type Heater  Natural Draft Operation  Horizontal Tube Arrangement  Central Bridgewall  Gas fired floor mounted Burners  Process, SSH and SG Coils in Convection Section  Self- supported stack on top of Convection Section Existing Coker Heater PROCESS COIL 4 BARE ROWS SG COIL 7 FINNED ROWS SSH COIL 2 FINNED TUBES PROCESS COIL 7 FINNED ROWS #1 #2 CELL-1 CELL-2 #1 #1 #2 #2 #4 #4#3
  • 6. www.heatflux.com Stack Flue Gas Offtake Ducts Convection Section Platforms Radiant Header Boxes (New) Radiant Arch (New) Coker Heater (Isometric View) 6
  • 7. www.heatflux.com Coker Heater Operating Issues Coking  Frequent decoking requirement (every year)  Short tube life around 5-6 years Overheating and flame impingement on roof tubes  Longer flame lengths  Low roof tubes elevation  Firing Imbalance  Higher firing in outer cells by almost 30% 7
  • 8. www.heatflux.com Existing Geometry for CFD 8 Burner 1 Burner 2 Cell 1 Zone 1 Zone 2 Inner cell tubes Outer cell tubes No. of burners in CFD model: 6 Design heat release per burner: 3.0 MMBtu/hr
  • 9. www.heatflux.com Flue Gas Flow and Temperature Profile 9  Higher velocity flue gas is observed on the inner side  Higher flue gas temperature observed near the inner cell tubes Existing Design [°F] [ft/s]
  • 10. www.heatflux.com Radiant Heat Flux Profile 10  Radiant heat flux for inner cell tubes is higher as compared to the outer cell tubes Existing Design Inner Tubes Outer Tubes [Btu/hr.ft2]
  • 11. www.heatflux.com Flue Gas Temperature around Tubes 11 [°F] Inner Tubes Outer Tubes  Flue gas temperatures around inner cell tubes and outer cell tubes are significantly different Existing Design
  • 12. www.heatflux.com [°F] Flue Gas Flow and Temperature Profile 12  High flue gas temperature and velocity is reduced for the inner tubes Existing Operating[ft/s]
  • 13. www.heatflux.com Radiant Heat Flux 13 Inner Tubes Outer Tubes  Radiant heat flux is similar for inner and outer tubes for operating case Existing Operating [Btu/hr.ft2]
  • 14. www.heatflux.com Flue Gas Temperature around Tubes Inner Tubes Existing Operating [°F] Outer Tubes  Clearly, the difference in flue gas temperatures around inner and outer cell tubes have reduced significantly as compared to the design case  This reduction is because inner cells were fired at 30% lower firing rate than outer cells 14
  • 15. www.heatflux.com Design = 12 Psi Average = 17.58 Psi 10 13 16 18 21 24 15-May-14 8-Jan-15 2-Sep-15 26-Apr-16 19-Dec-16 14-Aug-17 Pressure,(Psi) TIME Fuel Gas Pressure 15 West Outer Cell West Center Cell Design = 12 Psi Average = 12.45 Psi 6 9 12 14 17 20 15-May-14 8-Jan-15 2-Sep-15 26-Apr-16 19-Dec-16 14-Aug-17 Pressure,(Psi) TIME Fuel gas pressure in outer cell is almost 40% higher than the fuel gas pressure in inner cells
  • 16. www.heatflux.com 1 (Pass inlet) 5 10 31 (Pass outlet) 800 810 820 830 840 850 860 870 880 890 900 1 2 3 4 5 6 7 8 9 10 11-15 TubeMetalTemperature,ºF Tube No(s). Operating: Inner Tubes Operating: Outer Tubes 0.6°F 1.5°F 4.2°F 5.2°F 4.8°F 5.8°F 6.8°F 6.8°F 7.6°F 5.6°F 7.5°F 800 810 820 830 840 850 860 870 880 890 900 1 2 3 4 5 6 7 8 9 10 11-15 TubeMetalTemperature,ºF Tube No(s). Design: Inner Tubes Design: Outer Tubes2.9°F 7.7°F 13.4°F 15.7°F 17.9°F 16.9°F 17.1°F 15.3°F 16.8°F 14.5°F 16.4°F TMT Comparison with Existing Design TMT difference between the inner and outer tubes has decreased for each of the tubes for the operating case where inner cell burners fire 30% lower than the outer cell burners Existing Design Existing Operating
  • 17. www.heatflux.com Flue Gas Temperature Profile 17 Operating Case For operating case flue gas temperature in the inner cell has reduced [°F] Design Case
  • 18. www.heatflux.com Radiant Heat Flux Profile 18 Design Case Operating Case Radiant tubes heat flux for inner tubes has been reduced for the operating case [Btu/hr.ft2]
  • 19. www.heatflux.com Radiant Re-Tubing Proposed Options (Design TMTs) 19 The design tube metal temperature comparison for existing and proposed options at design pressure of 215 psig: Case Tube Details Material Design TMT, °F Limiting Design Metal Temp, °F Existing 3.5” NPS Sch 80 9 Cr-1Mo 1,240 1,300 Proposed Option-1 4” OD, 0.4” MWT 9 Cr-1Mo 1,285 Proposed Option-2 SS347H 1,500 1,500 Proposed Option-3 (Finalized Option) 4.25” OD, 0.5” MWT 9 Cr-1Mo 1,300 1,300
  • 20. www.heatflux.com Radiant Coil Re-Tubing  No. of radiant tubes: 62 per box  Tube size: 4” OD, Sch 80  Heat transfer area: 7,770 ft2  Tube material: 9 Cr  Coker Mass Velocity-295 lbs/s ft2  Pressure drop-210 psi  Total radiant tubes: 66 per box  Addition of 4 new radiant tubes  2 tubes installed at outlet and 2 at roof  Tube size: 4.25” OD, 0.5” MWT  Heat transfer area: 8,880 ft2  Tube material: 9 Cr  Coker Mass Velocity-347 lbs/s ft2  Pressure Drop- 242 psi 20 Existing Design Proposed Design Radiant heat transfer area increased by 15% in the heater
  • 22. www.heatflux.com Existing & Proposed Design of Radiant Section 22 New Radiant Tubes (Each Cell) New Radiant Tubes (Each Cell) ProposedExisting CELL-1 CELL-2 #1 #1 #2 #2 #4 #4#3 #1 #2 #4#3 CELL-1 CELL-2
  • 23. www.heatflux.com Velocity Vectors  Flue gas velocity near inner tubes is very high and getting deflected downward  Flue gas velocity is shifted downward with addition of baffle  Roof tubes are away from flue gas Adding refractory baffle at the top further improves the flue gas recirculation pattern Existing Proposed Case with Baffle Proposed Case [ft/s]
  • 24. www.heatflux.com Flue Gas Temperature Contours Addition of refractory baffle further increased the distance of hot flue gas with respect to roof tubes  High temperature flue gas is touching the inner roof tubes  Shifting roof tubes reduces chances of flame impingement / coking issues 24 [°F] Existing Proposed Case with Baffle Proposed Case
  • 25. www.heatflux.com Radiant Tube Heat Flux (Arch) Maximum heat flux on roof tubes is reduced by ~4,200 Btu/hr.ft2 Proposed Case Heat Flux 18,651 Btu/hr.ft2 Heat Flux 14,443 Btu/hr.ft2 Existing 25 [Btu/hr.ft2]
  • 26. www.heatflux.com 5,000 9,000 13,000 17,000 21,000 25,000 0 5 10 15 20 25 30 RadiantHeatFlux,Btu/hr-ft2 Radiant Tube No. Comparison of Radiant Heat Flux Existing Proposed Case Roof Tubes Wall Tubes Tube wise comparison of heat flux shows considerable reduction for roof tubes Radiant Heat Flux – Inner Tubes 26
  • 27. www.heatflux.com Existing vs Proposed Design Parameters Units Existing Proposed Total Heat Duty MMBtu/hr 125.1 126.8 Process Heat Duty MMBtu/hr 112.1 114.2 Charge Flow Rate lb/hr 263,000 326,953 Outlet Temperature °F 950 935 Bridge Wall Temperature °F 1,620 1,552 Radiant Heat Duty MMBtu/hr 77.7 79.3 Radiant Heat Transfer Area ft2 7,770 8,880 Average / Maximum Radiant Heat Flux Btu/hr/ft2 10,000 / 17,000 8,932 / 15,184 Fluid Mass Velocity in Radiant Section lb/sec/ft2 295.9 431.0 27
  • 28. www.heatflux.com Future Revamping  The convection section needs upgrading. Feed outlet temperature from convection section is 650-660F as compared to design of 710F.  The flue gas temperature approach to the coker feed is around 250-300 F and can be reduced significantly.  Convection upgrade will substantially help the coker heater further.  Future revamping window opens up around 2026 28
  • 29. www.heatflux.com Thank you very much  Questions and Comments are Welcome 29 Travel Tip- Download “ Gypsy Guide for Hawaii” on your cell phone and start driving.