.Coker heaters are one of the most critical heaters in the refineries. The feed is heated to a very high temperature. Run length is one of the important factors for coker heaters. We have worked recently worked on a conventional Coker heater and implemented several improvements while retubing the radiant section.
2. www.heatflux.com
Coker Heaters
Most critical heaters in the refineries
Objective: Heavy feedstock is converted to higher value products, such as
gasoline, diesel fuel, LPG, and petroleum coke
Delayed coking is an endothermic reaction with the heater supplying heat
Coking in Tubes:
Pressure drop goes up
Tube metal temperatures go up
The rate of coke deposition determine Coker heater run length
Coke removal by steam spalling/pigging (1-4 days lost)
Any shutdown for coke removal causes production loss
2
3. www.heatflux.com
Coker Heater Typical Design Parameters
Inlet temperature
500-600°F
Outlet temperature
900-950°F
Coil Pressure Drop
350-450 Psi (EOR)
Condensate Flow Rate
0.5–1% of heater feed
Average Heat Flux
< 10,000 Btu/hr.ft2 (Single
Fired)
Mass velocity
350-550 lb/sec.ft2
Cold oil velocity
around 6-10 ft/s
3
4. www.heatflux.com
Coker Heater
4
Twin Cell Box Type Heater
Natural Draft Operation
Horizontal Tube Arrangement
Central Bridgewall
Gas fired floor mounted Burners
Process, SSH and SG Coils in
Convection Section
Self- supported stack on top of
Convection Section
Existing Coker Heater
PROCESS COIL
4 BARE ROWS
SG COIL
7 FINNED ROWS
SSH COIL
2 FINNED TUBES
PROCESS COIL
7 FINNED ROWS
#1 #2
CELL-1 CELL-2
#1
#1
#2
#2
#4
#4#3
7. www.heatflux.com
Coker Heater Operating Issues
Coking
Frequent decoking requirement (every year)
Short tube life around 5-6 years
Overheating and flame impingement on roof tubes
Longer flame lengths
Low roof tubes elevation
Firing Imbalance
Higher firing in outer cells by almost 30%
7
8. www.heatflux.com
Existing Geometry for CFD
8
Burner 1 Burner 2
Cell 1
Zone 1 Zone 2
Inner cell
tubes
Outer cell tubes
No. of burners in
CFD model: 6
Design heat release
per burner: 3.0
MMBtu/hr
9. www.heatflux.com
Flue Gas Flow and Temperature Profile
9
Higher
velocity flue
gas is
observed on
the inner side
Higher flue
gas
temperature
observed near
the inner cell
tubes
Existing Design
[°F]
[ft/s]
10. www.heatflux.com
Radiant Heat Flux Profile
10
Radiant heat flux for
inner cell tubes is
higher as compared to
the outer cell tubes
Existing Design
Inner Tubes Outer Tubes
[Btu/hr.ft2]
11. www.heatflux.com
Flue Gas Temperature around Tubes
11
[°F]
Inner Tubes Outer Tubes
Flue gas temperatures around
inner cell tubes and outer cell
tubes are significantly
different
Existing Design
12. www.heatflux.com
[°F]
Flue Gas Flow and Temperature Profile
12
High flue gas temperature and
velocity is reduced for the inner
tubes
Existing Operating[ft/s]
14. www.heatflux.com
Flue Gas Temperature around Tubes
Inner Tubes
Existing Operating
[°F]
Outer Tubes
Clearly, the difference in
flue gas temperatures around
inner and outer cell tubes
have reduced significantly as
compared to the design case
This reduction is because
inner cells were fired at 30%
lower firing rate than outer
cells
14
15. www.heatflux.com
Design = 12 Psi
Average = 17.58 Psi
10
13
16
18
21
24
15-May-14 8-Jan-15 2-Sep-15 26-Apr-16 19-Dec-16 14-Aug-17
Pressure,(Psi)
TIME
Fuel Gas Pressure
15
West Outer Cell West Center Cell
Design = 12 Psi
Average = 12.45 Psi
6
9
12
14
17
20
15-May-14 8-Jan-15 2-Sep-15 26-Apr-16 19-Dec-16 14-Aug-17
Pressure,(Psi)
TIME
Fuel gas pressure in outer cell is almost 40% higher than the fuel gas
pressure in inner cells
16. www.heatflux.com
1
(Pass
inlet)
5
10
31
(Pass
outlet)
800
810
820
830
840
850
860
870
880
890
900
1 2 3 4 5 6 7 8 9 10 11-15
TubeMetalTemperature,ºF
Tube No(s).
Operating: Inner Tubes
Operating: Outer Tubes
0.6°F
1.5°F
4.2°F
5.2°F
4.8°F
5.8°F
6.8°F
6.8°F
7.6°F
5.6°F
7.5°F
800
810
820
830
840
850
860
870
880
890
900
1 2 3 4 5 6 7 8 9 10 11-15
TubeMetalTemperature,ºF
Tube No(s).
Design: Inner Tubes
Design: Outer Tubes2.9°F
7.7°F
13.4°F
15.7°F
17.9°F
16.9°F
17.1°F
15.3°F
16.8°F
14.5°F
16.4°F
TMT Comparison with Existing Design
TMT difference between the inner and outer tubes has decreased
for each of the tubes for the operating case where inner cell
burners fire 30% lower than the outer cell burners
Existing Design Existing Operating
17. www.heatflux.com
Flue Gas Temperature Profile
17
Operating Case
For operating case flue
gas temperature in the
inner cell has reduced
[°F]
Design Case
18. www.heatflux.com
Radiant Heat Flux Profile
18
Design Case Operating Case
Radiant tubes heat flux
for inner tubes has
been reduced for the
operating case
[Btu/hr.ft2]
19. www.heatflux.com
Radiant Re-Tubing Proposed Options
(Design TMTs)
19
The design tube metal temperature comparison for existing and proposed
options at design pressure of 215 psig:
Case Tube Details Material
Design
TMT, °F
Limiting
Design Metal
Temp, °F
Existing 3.5” NPS Sch 80 9 Cr-1Mo 1,240
1,300
Proposed Option-1
4” OD, 0.4” MWT
9 Cr-1Mo 1,285
Proposed Option-2 SS347H 1,500 1,500
Proposed Option-3
(Finalized Option)
4.25” OD, 0.5”
MWT
9 Cr-1Mo 1,300 1,300
20. www.heatflux.com
Radiant Coil Re-Tubing
No. of radiant tubes: 62 per box
Tube size: 4” OD, Sch 80
Heat transfer area: 7,770 ft2
Tube material: 9 Cr
Coker Mass Velocity-295 lbs/s ft2
Pressure drop-210 psi
Total radiant tubes: 66 per box
Addition of 4 new radiant tubes
2 tubes installed at outlet and 2
at roof
Tube size: 4.25” OD, 0.5” MWT
Heat transfer area: 8,880 ft2
Tube material: 9 Cr
Coker Mass Velocity-347 lbs/s ft2
Pressure Drop- 242 psi
20
Existing Design Proposed Design
Radiant heat transfer area increased by 15% in the heater
23. www.heatflux.com
Velocity Vectors
Flue gas velocity near inner
tubes is very high and getting
deflected downward
Flue gas velocity is shifted
downward with addition of baffle
Roof tubes are away from flue gas
Adding refractory baffle at the top further improves the flue gas recirculation pattern
Existing Proposed Case with
Baffle
Proposed Case
[ft/s]
24. www.heatflux.com
Flue Gas Temperature Contours
Addition of refractory baffle further increased the distance of hot flue gas with
respect to roof tubes
High temperature flue gas is
touching the inner roof tubes
Shifting roof tubes reduces chances of
flame impingement / coking issues
24
[°F]
Existing Proposed Case with
Baffle
Proposed Case
25. www.heatflux.com
Radiant Tube Heat Flux (Arch)
Maximum heat flux on roof tubes is reduced by ~4,200 Btu/hr.ft2
Proposed Case
Heat Flux 18,651 Btu/hr.ft2 Heat Flux 14,443 Btu/hr.ft2
Existing
25
[Btu/hr.ft2]
27. www.heatflux.com
Existing vs Proposed Design
Parameters Units Existing Proposed
Total Heat Duty MMBtu/hr 125.1 126.8
Process Heat Duty MMBtu/hr 112.1 114.2
Charge Flow Rate lb/hr 263,000 326,953
Outlet Temperature °F 950 935
Bridge Wall Temperature °F 1,620 1,552
Radiant Heat Duty MMBtu/hr 77.7 79.3
Radiant Heat Transfer Area ft2 7,770 8,880
Average / Maximum Radiant Heat Flux Btu/hr/ft2 10,000 / 17,000 8,932 / 15,184
Fluid Mass Velocity in Radiant Section lb/sec/ft2 295.9 431.0
27
28. www.heatflux.com
Future Revamping
The convection section needs upgrading. Feed outlet
temperature from convection section is 650-660F as
compared to design of 710F.
The flue gas temperature approach to the coker feed is
around 250-300 F and can be reduced significantly.
Convection upgrade will substantially help the coker heater
further.
Future revamping window opens up around 2026
28