3.1 Panel Description(1/2)
RTUMO
>Internal only
© ZTE Corporation. All rights reserved.
3.2 IP Address Configuration
• If RCUA is inserted in slot1, input 192.254.1.x in IP address;
• If RCUA is inserted in slot2, input 192.254.2.x in IP address;
• x range from 1 to 254, subnet mask is 255.255.255.0.
1
2
3
>Internal only
© ZTE Corporation. All rights reserved.
• Connect IDU and PC.
3.3 Logging in to Web LMT(1/2)
Direct or crossover Ethernet are all applicable.
>Internal only
© ZTE Corporation. All rights reserved.
• Logging in to the Equipment
– Double-click the internet Explorer on the desktop, input 192.154.1.16 as the IP
address of IDU and press Enter button, then enter the logging in page.
– Input user name admin in UserName.
– Input user name admin in Password .
– Click LOGIN to log in.
3.3 Logging in to Web LMT(2/2)
If RCUA is inserted in slot1, input 192.254.1.16;
If RCUA is inserted in slot2, input 192.254.2.16.
>Internal only
© ZTE Corporation. All rights reserved.
• Configuration should be according to network management plan.
• ZXMW NR8250 V1.00 supplies static route configuration function for connecting with third-
part equipments, and still the equipment works as L2 switch.
4.1 NE Basic Information Configuration
>Internal only
© ZTE Corporation. All rights reserved.
4.3 Shelf Configuration(1/2)
①
②
>Internal only
© ZTE Corporation. All rights reserved.
4.3 Shelf Configuration(2/2)
• According to the actual situation of the boards inserted in IDU’s slots,
set the following information for each SLOT NO.: Board Type,
Transmit Unit, Function, and select Master Slot or Slave Slot.
– If Function of RTUB board is set to STM-1 ADM/TM, E1 and STM-1
service are supported.
– If Function of RTUB board is set to STM-4 /STM-1 Transparent, E1,
STM-1 and STM-4 service are supported..
– Function is set to default for other types of boards.
• Note:
– Slot 1 can only be set to RCUA board.
– Slot 2 can be set to RCUA or RTU board.
– Slot 3-8 can be set to RTU or RMU board.
>Internal only
© ZTE Corporation. All rights reserved.
4.4.1 Transmit Unit
Configuration
①
②
③choose Transmit unit to configuration
>Internal only
© ZTE Corporation. All rights reserved.
4.4.2 Working Mode Configuration
• Select the bandwidth assigned to TDM service in the Work Mode drop-
down list box, and the rest bandwidth will be assigned to Ethernet service.
• Bandwidth and modulation mode decide the capacity of transmission.
Boarder bandwidth and higher modulation mode will offer more capacity at
the cost of transceiving performance degradation.
>Internal only
© ZTE Corporation. All rights reserved.
• Configure the Protection Type according to the MW design.
– No Protection indicates the system has no protection.
– HSB indicates the system adopts the protection of 1+1 hardware hot backup.
– SD indicates the system adopts the protection of antenna diversity reception.
– FD indicates the system adopts the protection of different transmitting and receiving
frequencies.
• If one type of protection is adopted, the Protection Mode can be configured.
– Revertive indicates when service signal on active path become normal, the service will
switch back to it, and the Revertive Time should be set, which range from 300s -800s.
– Automatic indicates the system will switchover automatically according to the status of
active and standby path.
– If Manual is selected, and the protection type is HSB or SD, the IF&RF Tx Path should be
specified. If protection type is FD, only IF TX Path need to be specified.
4.4.3 Protection Parameter Configuration
>Internal only
© ZTE Corporation. All rights reserved.
• If ATPC Enable is set to ON, ATPC High Threshold and ATPC Low Threshold should
also be configured. Usually, the two parameters are recommended to use the default
value.
• Max Tx Power and Min Tx Power need to be set within the range of ODU transmitting
power.
• When adjusting the antenna, ATPC Enable must be set to OFF.
4.4.4 ATPC Parameter Configuration
>Internal only
© ZTE Corporation. All rights reserved.
• The unit of Current Rx/Tx Frequency is kHz.
• The Tx Frequency should be set within the Tx Frequency Range.
• The RSL High Threshold and RSL Low Threshold can be set to
default value if there’s no special requirement.
4.4.6 ODU Parameter Configuration
>internal only
 Clock Synchronization Configuration
 Clock Synchronization Configuration Example
4.7 Clock Synchronization Configuration
>Internal only
© ZTE Corporation. All rights reserved.
• Current Clock Information
4.7.1 Clock Synchronization Configuration(1/4)
①
②
>Internal only
© ZTE Corporation. All rights reserved.
4.7.1 Clock Synchronization
Configuration(2/4)
• Clock Protection Switching Strategy :
– No Protection Policy:Only adopt the primary clock, if the primary clock degrades, it will keep
current frequency for a bit of time, then switch to enforced clock PLL free running.
– Auto-switching Policy(Non-real-time priority switching):Switch to subordinate clock if exists
when primary clock is degrading or lost and wouldn’t switch back to primary clock even if primary
clock turns normal.
– Optimal Switching Policy(Real-time priority switching): Switch to subordinate clock if exists
when primary clock is degrading or lost and switch back to primary clock if primary clock turns
normal.
• GPS M/S Stations:
– Mater Station:Select GPS Master Station when the clock in RCUA board works as clock source.
– Slave Station:Other conditions.
• BITS Clock Output:
– Open:Clock signal is output from CLK IN/OUT port.
– Close: No clock signal is output from CLK IN/OUT port.
• BITS Clock Mode can configure the clock mode,normally chose 2.048Mbps.
• Enforce Clock PLL Free Running can chose Yes or No,chose Yes when transmitting
synchronous Ethernet service.
• NE in Ring Network, configure according to real situation.
>Internal only
© ZTE Corporation. All rights reserved.
• Reference Clock Configuration
4.7.1 Clock Synchronization
Configuration(3/4)
①Select needed Clock Source
②Click to add to
right column
③Click Apply
>Internal only
© ZTE Corporation. All rights reserved.
4.7.1Clock Synchronization Configuration(4/4)
Mater Station Clock Source Slave Station Clock Source
• Clock Source Configuration

Mais conteúdo relacionado

Mais procurados

Lte network planning huawei technologies
Lte network planning huawei technologiesLte network planning huawei technologies
Lte network planning huawei technologies
Chaudary Imran
 
Mini link tn configuration
Mini link tn configurationMini link tn configuration
Mini link tn configuration
Hammad Tabish
 
01 Bts3900 System Structure
01 Bts3900 System Structure01 Bts3900 System Structure
01 Bts3900 System Structure
Atif Mahmood
 
Ericsson technical interview questions
Ericsson technical interview questionsEricsson technical interview questions
Ericsson technical interview questions
sethshivam75
 

Mais procurados (20)

Huawei sran site configration principles
Huawei sran site configration principlesHuawei sran site configration principles
Huawei sran site configration principles
 
Prof. Andy Sutton: 5G RAN Architecture Evolution - Jan 2019
Prof. Andy Sutton: 5G RAN Architecture Evolution - Jan 2019Prof. Andy Sutton: 5G RAN Architecture Evolution - Jan 2019
Prof. Andy Sutton: 5G RAN Architecture Evolution - Jan 2019
 
Antenna Installation Engineering.
Antenna Installation Engineering.Antenna Installation Engineering.
Antenna Installation Engineering.
 
SRAN19 dimensioning.pdf
SRAN19 dimensioning.pdfSRAN19 dimensioning.pdf
SRAN19 dimensioning.pdf
 
Huawei GSM Principles
Huawei GSM PrinciplesHuawei GSM Principles
Huawei GSM Principles
 
اساسيات الاتصالات وشبكات المحمول للدكتور مصطفي محمد الجماله
اساسيات الاتصالات وشبكات المحمول للدكتور مصطفي محمد الجمالهاساسيات الاتصالات وشبكات المحمول للدكتور مصطفي محمد الجماله
اساسيات الاتصالات وشبكات المحمول للدكتور مصطفي محمد الجماله
 
ZXSDR Trainning
ZXSDR TrainningZXSDR Trainning
ZXSDR Trainning
 
02 opti x rtn 900 v100r002 system hardware-20100223-a
02 opti x rtn 900 v100r002 system hardware-20100223-a02 opti x rtn 900 v100r002 system hardware-20100223-a
02 opti x rtn 900 v100r002 system hardware-20100223-a
 
Lte network planning huawei technologies
Lte network planning huawei technologiesLte network planning huawei technologies
Lte network planning huawei technologies
 
Handling Common Faults and Alarms for Huawei RTN Microwaves
Handling Common Faults and Alarms for Huawei RTN MicrowavesHandling Common Faults and Alarms for Huawei RTN Microwaves
Handling Common Faults and Alarms for Huawei RTN Microwaves
 
Mw frequency planning
Mw frequency planningMw frequency planning
Mw frequency planning
 
Lte irat-troubleshooting-guide
Lte irat-troubleshooting-guideLte irat-troubleshooting-guide
Lte irat-troubleshooting-guide
 
Mini link tn configuration
Mini link tn configurationMini link tn configuration
Mini link tn configuration
 
Huawei RET alarms Troubleshooting Guide Flow Chart
Huawei RET alarms Troubleshooting Guide   Flow Chart Huawei RET alarms Troubleshooting Guide   Flow Chart
Huawei RET alarms Troubleshooting Guide Flow Chart
 
ZTE BTS Manual
ZTE BTS ManualZTE BTS Manual
ZTE BTS Manual
 
Ericsson RBS 6000 & 3000 & 2000
Ericsson RBS 6000 & 3000 & 2000Ericsson RBS 6000 & 3000 & 2000
Ericsson RBS 6000 & 3000 & 2000
 
ZTE BTS Cards Description
ZTE BTS Cards DescriptionZTE BTS Cards Description
ZTE BTS Cards Description
 
E nodeb commissioning guide(v100r005c00 04)(pdf)-en
E nodeb commissioning guide(v100r005c00 04)(pdf)-enE nodeb commissioning guide(v100r005c00 04)(pdf)-en
E nodeb commissioning guide(v100r005c00 04)(pdf)-en
 
01 Bts3900 System Structure
01 Bts3900 System Structure01 Bts3900 System Structure
01 Bts3900 System Structure
 
Ericsson technical interview questions
Ericsson technical interview questionsEricsson technical interview questions
Ericsson technical interview questions
 

Semelhante a Zxmw nr8250 v1.00 commissioning guide ¸±±¾

Mobilink Project On Site Swap SOP V2_4
Mobilink Project On Site Swap SOP V2_4Mobilink Project On Site Swap SOP V2_4
Mobilink Project On Site Swap SOP V2_4
ij qkka
 
3gpp architecture evolution
3gpp architecture evolution3gpp architecture evolution
3gpp architecture evolution
philip habib
 
Iai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheetIai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheet
Electromate
 

Semelhante a Zxmw nr8250 v1.00 commissioning guide ¸±±¾ (20)

8051
80518051
8051
 
Narrowband IoT
Narrowband IoTNarrowband IoT
Narrowband IoT
 
Commisioning.pptx
Commisioning.pptxCommisioning.pptx
Commisioning.pptx
 
Routing over ericsson mini link
Routing over ericsson mini linkRouting over ericsson mini link
Routing over ericsson mini link
 
Fttx arcitectures
Fttx arcitecturesFttx arcitectures
Fttx arcitectures
 
Mobilink Project On Site Swap SOP V2_4
Mobilink Project On Site Swap SOP V2_4Mobilink Project On Site Swap SOP V2_4
Mobilink Project On Site Swap SOP V2_4
 
3gpp architecture evolution
3gpp architecture evolution3gpp architecture evolution
3gpp architecture evolution
 
Zxdu68 t601 product description v1.0 20101221 en
Zxdu68 t601 product description v1.0 20101221 enZxdu68 t601 product description v1.0 20101221 en
Zxdu68 t601 product description v1.0 20101221 en
 
NanoX - Overview
NanoX - OverviewNanoX - Overview
NanoX - Overview
 
Wireless communication netwrks.unit 5...3gpp architecture evolution
Wireless communication netwrks.unit 5...3gpp architecture evolutionWireless communication netwrks.unit 5...3gpp architecture evolution
Wireless communication netwrks.unit 5...3gpp architecture evolution
 
Iai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheetIai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheet
 
Microprocessors-based systems (under graduate course) Lecture 9 of 9
Microprocessors-based systems (under graduate course) Lecture 9 of 9 Microprocessors-based systems (under graduate course) Lecture 9 of 9
Microprocessors-based systems (under graduate course) Lecture 9 of 9
 
BRKRST-3068 Troubleshooting Catalyst 2K and 3K.pdf
BRKRST-3068  Troubleshooting Catalyst 2K and 3K.pdfBRKRST-3068  Troubleshooting Catalyst 2K and 3K.pdf
BRKRST-3068 Troubleshooting Catalyst 2K and 3K.pdf
 
EMEA Airheads- Switch stacking_ ArubaOS Switch
EMEA Airheads- Switch stacking_ ArubaOS SwitchEMEA Airheads- Switch stacking_ ArubaOS Switch
EMEA Airheads- Switch stacking_ ArubaOS Switch
 
3 g rf_optimisation_basics
3 g rf_optimisation_basics3 g rf_optimisation_basics
3 g rf_optimisation_basics
 
Motorola MotoTRBO Firmware 2.3A Release Notes (June 2014)
Motorola MotoTRBO Firmware 2.3A Release Notes (June 2014)Motorola MotoTRBO Firmware 2.3A Release Notes (June 2014)
Motorola MotoTRBO Firmware 2.3A Release Notes (June 2014)
 
Bluetooth Home Automation
Bluetooth Home AutomationBluetooth Home Automation
Bluetooth Home Automation
 
8086 Programing.ppt
8086 Programing.ppt8086 Programing.ppt
8086 Programing.ppt
 
Mitsubishi inverter catalog-fr-e700-mitsubishi-160425074315
Mitsubishi inverter catalog-fr-e700-mitsubishi-160425074315Mitsubishi inverter catalog-fr-e700-mitsubishi-160425074315
Mitsubishi inverter catalog-fr-e700-mitsubishi-160425074315
 
Mitsubishi inverter catalog-fr-e700-mitsubishi dienhathe.vn
Mitsubishi inverter catalog-fr-e700-mitsubishi dienhathe.vnMitsubishi inverter catalog-fr-e700-mitsubishi dienhathe.vn
Mitsubishi inverter catalog-fr-e700-mitsubishi dienhathe.vn
 

Último

Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 

Último (20)

ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Corporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptxCorporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptx
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​
 
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot ModelMcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
Vector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxVector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptx
 
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
Web Form Automation for Bonterra Impact Management (fka Social Solutions Apri...
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering Developers
 
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 

Zxmw nr8250 v1.00 commissioning guide ¸±±¾

  • 1. >Internal only © ZTE Corporation. All rights reserved. 3.1 Panel Description(1/2) RTUMO
  • 2. >Internal only © ZTE Corporation. All rights reserved. 3.2 IP Address Configuration • If RCUA is inserted in slot1, input 192.254.1.x in IP address; • If RCUA is inserted in slot2, input 192.254.2.x in IP address; • x range from 1 to 254, subnet mask is 255.255.255.0. 1 2 3
  • 3. >Internal only © ZTE Corporation. All rights reserved. • Connect IDU and PC. 3.3 Logging in to Web LMT(1/2) Direct or crossover Ethernet are all applicable.
  • 4. >Internal only © ZTE Corporation. All rights reserved. • Logging in to the Equipment – Double-click the internet Explorer on the desktop, input 192.154.1.16 as the IP address of IDU and press Enter button, then enter the logging in page. – Input user name admin in UserName. – Input user name admin in Password . – Click LOGIN to log in. 3.3 Logging in to Web LMT(2/2) If RCUA is inserted in slot1, input 192.254.1.16; If RCUA is inserted in slot2, input 192.254.2.16.
  • 5. >Internal only © ZTE Corporation. All rights reserved. • Configuration should be according to network management plan. • ZXMW NR8250 V1.00 supplies static route configuration function for connecting with third- part equipments, and still the equipment works as L2 switch. 4.1 NE Basic Information Configuration
  • 6. >Internal only © ZTE Corporation. All rights reserved. 4.3 Shelf Configuration(1/2) ① ②
  • 7. >Internal only © ZTE Corporation. All rights reserved. 4.3 Shelf Configuration(2/2) • According to the actual situation of the boards inserted in IDU’s slots, set the following information for each SLOT NO.: Board Type, Transmit Unit, Function, and select Master Slot or Slave Slot. – If Function of RTUB board is set to STM-1 ADM/TM, E1 and STM-1 service are supported. – If Function of RTUB board is set to STM-4 /STM-1 Transparent, E1, STM-1 and STM-4 service are supported.. – Function is set to default for other types of boards. • Note: – Slot 1 can only be set to RCUA board. – Slot 2 can be set to RCUA or RTU board. – Slot 3-8 can be set to RTU or RMU board.
  • 8. >Internal only © ZTE Corporation. All rights reserved. 4.4.1 Transmit Unit Configuration ① ② ③choose Transmit unit to configuration
  • 9. >Internal only © ZTE Corporation. All rights reserved. 4.4.2 Working Mode Configuration • Select the bandwidth assigned to TDM service in the Work Mode drop- down list box, and the rest bandwidth will be assigned to Ethernet service. • Bandwidth and modulation mode decide the capacity of transmission. Boarder bandwidth and higher modulation mode will offer more capacity at the cost of transceiving performance degradation.
  • 10. >Internal only © ZTE Corporation. All rights reserved. • Configure the Protection Type according to the MW design. – No Protection indicates the system has no protection. – HSB indicates the system adopts the protection of 1+1 hardware hot backup. – SD indicates the system adopts the protection of antenna diversity reception. – FD indicates the system adopts the protection of different transmitting and receiving frequencies. • If one type of protection is adopted, the Protection Mode can be configured. – Revertive indicates when service signal on active path become normal, the service will switch back to it, and the Revertive Time should be set, which range from 300s -800s. – Automatic indicates the system will switchover automatically according to the status of active and standby path. – If Manual is selected, and the protection type is HSB or SD, the IF&RF Tx Path should be specified. If protection type is FD, only IF TX Path need to be specified. 4.4.3 Protection Parameter Configuration
  • 11. >Internal only © ZTE Corporation. All rights reserved. • If ATPC Enable is set to ON, ATPC High Threshold and ATPC Low Threshold should also be configured. Usually, the two parameters are recommended to use the default value. • Max Tx Power and Min Tx Power need to be set within the range of ODU transmitting power. • When adjusting the antenna, ATPC Enable must be set to OFF. 4.4.4 ATPC Parameter Configuration
  • 12. >Internal only © ZTE Corporation. All rights reserved. • The unit of Current Rx/Tx Frequency is kHz. • The Tx Frequency should be set within the Tx Frequency Range. • The RSL High Threshold and RSL Low Threshold can be set to default value if there’s no special requirement. 4.4.6 ODU Parameter Configuration
  • 13. >internal only  Clock Synchronization Configuration  Clock Synchronization Configuration Example 4.7 Clock Synchronization Configuration
  • 14. >Internal only © ZTE Corporation. All rights reserved. • Current Clock Information 4.7.1 Clock Synchronization Configuration(1/4) ① ②
  • 15. >Internal only © ZTE Corporation. All rights reserved. 4.7.1 Clock Synchronization Configuration(2/4) • Clock Protection Switching Strategy : – No Protection Policy:Only adopt the primary clock, if the primary clock degrades, it will keep current frequency for a bit of time, then switch to enforced clock PLL free running. – Auto-switching Policy(Non-real-time priority switching):Switch to subordinate clock if exists when primary clock is degrading or lost and wouldn’t switch back to primary clock even if primary clock turns normal. – Optimal Switching Policy(Real-time priority switching): Switch to subordinate clock if exists when primary clock is degrading or lost and switch back to primary clock if primary clock turns normal. • GPS M/S Stations: – Mater Station:Select GPS Master Station when the clock in RCUA board works as clock source. – Slave Station:Other conditions. • BITS Clock Output: – Open:Clock signal is output from CLK IN/OUT port. – Close: No clock signal is output from CLK IN/OUT port. • BITS Clock Mode can configure the clock mode,normally chose 2.048Mbps. • Enforce Clock PLL Free Running can chose Yes or No,chose Yes when transmitting synchronous Ethernet service. • NE in Ring Network, configure according to real situation.
  • 16. >Internal only © ZTE Corporation. All rights reserved. • Reference Clock Configuration 4.7.1 Clock Synchronization Configuration(3/4) ①Select needed Clock Source ②Click to add to right column ③Click Apply
  • 17. >Internal only © ZTE Corporation. All rights reserved. 4.7.1Clock Synchronization Configuration(4/4) Mater Station Clock Source Slave Station Clock Source • Clock Source Configuration