Gie Cable Gland (Suryoday Enterprise) is a one of the leading Brass Double Cable Gland Manufacturers, Suppliers & Exporters in India, Based in Jamnagar, Gujarat.
2. “Thinking Larger, Moving Faster”
Creating The Momentum To Reach Our Goal.
Momentum is defined as the energy of a moving body measured
capabilities and development with an ability to move with
remarkable speed and accuracy. In doing so, we have created a
significant momentum.
The Company
engaged in manufacturing of cable glands & electrical
accessories since last two decades. We are operating in steps
with the advances of CNC technology, automated systems and
products in the field of Electrical accessories.
As a family business in the 2nd generation, we are well aware of
the inter-relationships between creative ideas, their flexible
realisation and partner-like dealings with employees, suppliers
and customers. This leaves its mark on how we think and act.
We provide backing for trusting co-operation on all levels. Doing
this together, the upshot is success across the board, so that we
are capable of maintaining ourselves in the global market.
Our extensive experience, together with the latest technology
enables us to manufacture Cable Glands which cover the whole
spectrum of armoured and unarmoured cable and applications
from general industrial through increased safety, deluge,
flameproof and explosion proof. Our products have to be capable
of withstanding mechanical stress and must reliably protect
electrical installations from damp and dirt, so that power can
flow without hindrance, thus providing complete solution of
cable termination to the industry in both hazardous and
non-hazardous area of electrical installations. The Cable Glands
are available in Brass as standard with Stainless Steel,
Aluminium and Plastic as an optional material on certain designs.
satisfy the demands of the various testing bodies and
authorities like CIMFR (erstwhile CMRI) and others.
partners, well known authorised dealers and distributors. This
proximity leads to intensive talks with users from the most varied
branches and markets. The results of such interchanges form
the basis for our products and services of tomorrow.
Technical competence and creativity marks co-operation with
facilities during late 90's when sate-of-the-art machinery and
testing equipment were acquired. Thereafter, new machines are
recurrently being introduced to enhance our product capacity and
product range. The new machines and equipment have numerous
built-in functions and features assuring precision and consistency
of the highest standard.
From the very first idea and then construction on state-of-the-art
3D CAD installations, from production on a flexible fleet of
anything to chance. It is our company goal to translate ideas that
are ready to come into the market for cable gland management
into quality products made of high-grade materials. To this end,
we implement ecologically-friendly production processes and
draw up detailed documentation on the products manufactured
and the processes involved. This gives our customers the safety
and reliable functioning they need.
While there is no defined path to success for any business, we
firmly believe that there are certain principles that are essential:
put the customer first, let their requirements be your guide, do the
job right the first time and never allow conventional wisdom to
making our company one of the top in our industry. Our strategy
for attaining this level of success, while ambitious, is simple.
Simple, however, does not mean easy, and we understand the
challenges that are ahead of us. Since our inception, we have
worked diligently to assemble the team and technology we need
to address those challenges and maintain our momentum.
An Ambitious Strategy
TM
Suryoday Enterprise, on the leading edge of technology, is
by its mass and speed. At Suryoday, we have combined extensive
advance manufacturing processes and techniques. Suryoday
known in the Indian market as manufacturers of premium quality
At SEP we embarked upon a massive restoration of our plant & its
Suryoday Enterprise (SEP) and their partners.
GIE Cable Glands are designed, manufactured and tested to
SEP is directly represented throughout INDIA by experienced
stand in the way of innovation.
At SEP, we live these ideals daily, and we are committed to
machines right up to on-time delivery, SEP does not leave
3. "Our vision has always been to excel in our performance and
achieve perfection in what we are doing. Flawless production,
timely delivery and competitive pricing are the characteristics of
our organisation."
Our Vision
product to our valued customers. We ensure to supply complaint
free product to achieve complete customer satisfaction through
continual improvement.
Quality Policy
To continuously improve our products and service, we believe
that a perfect understanding of the clients need is of crucial
importance and also adhere to the concept of corporate social
responsibility.
Our Values
in the creation of long standing commercial relationships built on
close working relationship with its customers and has a much
focused market driven philosophy.
Our commitment is to understand and exceed the expectations of
our valued customers, while delivering high quality product,
services, and solutions to their most demanding requirements.
Our Commitment
environment, produce safe and accurate products, commit to
TM
Suryoday Enterprise is committed to supply timely quality
mutual trust and understanding. SEP prides itself in having a very pollution prevention, and protect the natural environment.
customer's particular requirement or requirements which results from hazards, and wants its employees to work in an injury-free
Business Philosophy Health and Safety Policy
Our philosophy is to find the best engineering solution for the Suryoday Enterprise firmly believes in its workplace being safe
4. List of Contents
Page 001 Field of Applications & Our Reputed Clients
Page 002 Single Compression Heavy Duty Cable Glands
Page 004 Double Compression Weather Proof Cable Glands
Page 006 Double Compression Flame Proof (Gas Group I, IIA & IIB) Cable Glands
Page 008 Double Compression Flame Proof (Gas Group IIC) Cable Glands
Page 010 Single Compression Medium Duty Cable Glands
Page 011 Double Compression Medium Duty Cable Glands
Page 012 Flange Type Cable Glands
Page 013 Other Types of Cable Glands
Page 014 Accessories
Page 016 Cable Glands Selection Chart for Unarmoured Power Cable
Page 018 Cable Glands Selection Chart for Unarmoured Control Cable
Page 019 Cable Glands Selection Chart for Armoured Power Cable
Page 022 Cable Glands Selection Chart for Armoured Control Cable
Page 023 Cable Glands Selection Chart on the Basis of Cable Overall Dia.
TM
5. Electric Power Generation & Distribution Industries
Control Panels, Switch gears, Transformers
Mining Industries
Cement Industries
Iron & Steel Industries
Petroleum Industries
Chemical Industries
Fertilizer Industries
Sugar Industries
Satellite & Communication Industries
Aeronautic Industries
Automobile Industries
Railways
Shipping Industries
Textile Industries
Defence Industries & Other Industries
Field of Applications
Page 01
TM
6. Material : Brass (IS-319) Standard
(Al. / S.S. / M.S. also available)
Plating : Nickle Plated Standard
(Chrome also available)
Entry Threads : Metric threads with 1.5 pitch as per
IS 4218 standard
Sealing Rubber Ring : Synthetic / Natural
Gland Standard : IS 12943 : 1990
Ingress Protection : IP 60 as per IS 12063
Technical Data:
Application:
can be used in normal climatic condition. Also when protected by PVC
shrouds it can be used in corrosive atmosphere.
These glands are available in different sizes and are suitable for all cables
upto 1000 sq. mm. and control cables upto 61 cores.
Accessories:
PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available
with specified dimensions in accordance to the Gland separately.
Fitting Sequence:
(a) Pass the Compression Nut (Part-5), one Metal Washer (Part-3) & Outer
Seal Ring (Part-4) in succession order over the outer sheath of the
cable before commencing to strip the cable
(b) Remove the outer sheath to the desired length depending on the length
of the beds required.
(c) Pass the 2nd Metal Washer (Part-3) over the exposed armour and then
splay out the armour wire one by one. Now cut the armour wire
according to the size of the metal washer and bend the same. Pass the
3rd Metal Washer (Part-3) over the inner sheath and place it over the
bended armour, so that the armour wires are now secured between the
two Metal Washer.
(d) Push the assembly through the Gland Body (Part-2) and tighten the
Compression Nut (Part-5). While doing so the outer seal ring will
expand in radial direction and will grip the cable. This will ensure dust
proof entry of the cable.
(e) Finally apply the fitted gland assembly to the extreme with the entry
thread provided, if the enclosure does not have threaded entry than tight
the gland assembly with the Check Nut (Part-1).
Designation:
Single Compression Glands are designated as below :
SCGn, where
SC Single Compression
G Gland
n(n=1, 2,....20) Gland Size For eg.(SCG1, SCG2,...... SCG20)
Page 02
TM
Single Compression Glands are weather proof and dust proof (IP-60) which
Single Compression Heavy Duty Cable Glands
7. Suitable Cable Size
D1
D2 D3 D4 D5 L1
Nipple Entry
Overall Dia Code
Threads in Metrics
Dia. Dia. (A/F) (A/C) Length
From To SCG mm Ø mm Ø mm mm mm mm
9.0 12.0 SCG 1 16 x 1.5 12.0 16.0 22.0 25.5 9.0
12.0 15.0 SCG 2 16 x 1.5 12.0 18.5 25.0 29.0 9.0
12.0 15.0 SCG 3 20 x 1.5 15.0 18.5 25.0 29.0 9.0
15.0 18.0 SCG 4 20 x 1.5 15.0 24.0 30.0 34.5 9.5
16.0 20.0 SCG 5 25 x 1.5 20.5 24.0 31.5 36.0 9.5
20.0 24.0 SCG 6 25 x 1.5 20.5 28.5 35.0 40.0 10.0
24.0 28.0 SCG 7 32 x 1.5 27.0 33.0 40.0 46.0 12.0
28.0 32.0 SCG 8 40 x 1.5 34.0 37.0 46.0 53.0 12.0
33.0 37.0 SCG 9 40 x 1.5 34.0 41.0 50.0 57.5 12.0
37.0 42.0 SCG 10 50 x 1.5 44.0 47.0 58.0 67.0 13.0
43.0 48.0 SCG 11 50 x 1.5 44.0 52.0 65.0 75.0 13.0
49.0 54.0 SCG 12 63 x 1.5 55.0 61.5 73.0 84.0 14.0
55.0 60.0 SCG 13 63 x 1.5 55.0 65.0 77.0 89.0 14.0
61.0 66.0 SCG 14 75 x 1.5 68.0 71.0 85.0 98.0 15.0
67.0 72.0 SCG 15 75 x 1.5 67.0 76.0 90.0 104.0 15.0
73.0 78.0 SCG 16 82 x 1.5 73.0 82.0 97.0 112.0 17.0
79.0 84.0 SCG 17 90 x 1.5 81.0 91.0 108.0 124.0 19.0
84.5 92.0 SCG 18 100 x 1.5 91.0 98.0 117.0 135.0 20.0
93.0 100.0 SCG 19 110 x 1.5 100.0 107.0 127.0 146.0 25.0
101.0 115.0 SCG 20 125 x 1.5 113.0 118.0 142.0 164.0 25.0
3
Metal Washer
3
Metal Washer
3
Metal Washer
2
Gland Body
5
Compression Nut
1
Check Nut
4
Outer Sealing Ring
L1
D1 D2 D3
D4
D5
Page 03Tolerance ± 1mm
TM
Single Compression Heavy Duty Cable Glands
8. Material : Brass (IS-319) Standard
(Al. / S.S. / M.S. also available)
Plating : Nickle Plated Standard
(Chrome also available)
Entry Threads : BSC Standard
(PG / Metric / NPT / BSP / also available)
Sealing Rubber Ring : Nitrile / Neoprene
Gland Standard : BS 6121
Ingress Protection : IP 66 as per IS 12063
Technical Data:
Application:
Weather Proof Double Compression Glands are weather proof and dust proof
(IP-66) which can be used in normal climatic condition. Also when protected
by PVC shrouds it can be used in corrosive atmosphere.
These glands are available in different sizes and are suitable for all cables
upto 1000 sq. mm. and control cables upto 61 cores.
Accessories:
PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available
with specified dimensions in accordance to the Gland separately.
Fitting Sequence:
(a)
(b)
(c)
(d)
(e)
Insert Part No. 9, 8 & 7 respectively on the Outer Sheath of the cable
before exposing the Armour.
After removing Outer Sheath of the cable, Insert Part No. 6 over the
Exposed Armour.
Size Armour length, Lift Armour & Insert Part No. 5 under the Armour,
Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No.
6 towards it.
Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part
No. 7 & Tight Part No. 9 with Part No. 7.
Finally apply the full fitted Gland in the Enclosure with the entry thread
provided, if the Enclosure does not have threaded entry than tight the
Gland with the Part No. 1 provided.
Page 04
TM
Double Compression Weather Proof Cable Glands
10. (Gas Group I, IIA & IIB)
Technical Data:
Material : Brass (IS-319) Standard,
(Al. / S.S. / M.S. also available)
Plating : Nickle Plated Standard,
(Chrome also available)
Entry Threads : BSC Standard
(PG / Metric / NPT / BSP / also available)
Sealing Rubber Ring : Neoprene
Gland Standard : BS 6121, IS 2148: 2004
Ingress Protection : IP 65 as per IS 12063 - 1987
Application:
Flame Proof Double Compression Glands are generally used in flammable
gas / vapours area (for gas group I, IIA & IIB) as well as in normal climatic
conditions also which are weather proof, water proof and dust proof (IP-65)
which can be used in Hazardous climatic condition. Also when protected by
PVC shrouds it can be used in corrosive atmosphere.
These glands are available in different sizes and are suitable for all cables
upto 1000 sq. mm. and control cables upto 61 cores.
Accessories:
PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available
with specified dimensions in accordance to the Gland separately.
Fitting Sequence:
(a)
(b)
(c)
(d)
(e)
Insert Part No. 9, 8 & 7 respectively on the Outer Sheath of the cable
before exposing the Armour.
After removing Outer Sheath of the cable, Insert Part No. 6 over the
Exposed Armour.
Size Armour length, Lift Armour & Insert Part No. 5 under the Armour,
Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No.
6 towards it.
Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part
No. 7 & Tight Part No. 9 with Part No. 7.
Finally apply the full fitted Gland in the Enclosure with the entry thread
provided, if the Enclosure does not have threaded entry than tight the
Gland with the Part No. 1 provided.
Page 06
TM
Double Compression Flame Proof Cable Glands
12. (Gas Group IIC)
Material : Brass (IS-319) Standard
(Al. / S.S. / M.S. also available)
Plating : Nickle Plated Standard
(Chrome also available)
Entry Threads : BSC Standard
(PG / Metric / NPT / BSP / also available)
Sealing Rubber Ring : Neoprene
Gland Standard : BS 6121
Standard Ref. : (a) As to general requirement IS:13346-2004
(b) As to flameproof construction IS:2148:2004
(c) As to weatherproof construction
IP-65: IS:12063-1987
Technical Data:
Application:
Flame Proof Double Compression Glands are generally used in hydrogen
gas/vapours area (for gas group IIC) as well as in normal climatic conditions
also which are weather proof, water proof and dust proof (IP-65) which can
be used in Hazardous climatic condition. Also when protected by PVC
shrouds it can be used in corrosive atmosphere.
These glands are available in different sizes and are suitable for all cables
upto 1000 sq. mm. and control cables upto 61 cores.
Accessories:
PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available
with specified dimensions in accordance to the Gland separately.
Fitting Sequence:
(a)
(b)
(c)
(d)
(e)
Insert Part No. 10, 9, 8 & 7 respectively on the Outer Sheath of the
cable before exposing the Armour.
After removing Outer Sheath of the cable, Insert Part No. 6 over the
Exposed Armour.
Size Armour length, Lift Armour & Insert Part No. 5 under the Armour,
Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No.
6 towards it.
Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part
No. 7 & Tight Part No. 10 with Part No. 7.
Finally apply the full fitted Gland in the Enclosure with the entry thread
provided, if the Enclosure does not have thread than tight the Gland with
the Part No. 1 provided.
Page 08
TM
Double Compression Flame Proof Cable Glands
15. Page 11
Suitable Cable
Size
A B C D E F
Overall Dia Nipple Entry Length (A/F) (A/C) Dia. Dia.
From To mm inches Inches mm mm mm Ø mm Ø mm
6.0 9.0 10 3/8" 5/8" 25.0 20.5 23.5 10.0 7.0
6.0 12.0 12 1/2" 5/8" 25.0 23.0 26.0 13.5 11.0
12.0 16.5 16 5/8" 3/4" 25.0 23.0 26.0 16.5 14.0
16.5 18.5 19 3/4" 3/4" 25.0 25.5 29.5 19.0 14.0
18.5 20.0 22 7/8" 3/4" 25.0 28.0 32.0 20.0 14.0
20.0 23.0 25 1" 1" 25.0 31.5 36.0 23.5 19.0
23.0 26.0 28 1 1/8" 1 1/8" 25.0 35.5 41.0 27.0 22.5
26.0 30.0 32 1 1/4" 1 1/4" 25.0 41.0 47.0 32.0 25.5
30.0 33.0 35 1 3/8" 1 1/2" 25.0 44.0 50.5 35.0 27.5
33.0 37.0 38 1 1/2" 1 1/2" 25.0 46.0 53.0 38.0 31.0
37.0 41.0 45 1 3/4" 2" 25.0 57.0 65.5 44.5 42.0
41.0 46.0 50 2" 2" 25.0 61.0 70.5 51.0 42.0
46.0 52.0 57 2 1/4" 2 1/4" 25.0 67.0 77.0 57.0 50.0
52.0 54.0 63 2 1/2" 2 1/2" 25.0 79.0 91.0 63.0 54.5
54.0 61.0 70 2 3/4" 2 3/4" 25.0 82.0 95.0 69.5 62.0
61.0 72.0 75 3" 3" 25.0 90.0 105.0 75.0 65.0
72.0 78.0 82 3 1/4" 3 1/4" 25.0 95.0 109.0 82.0 74.5
78.0 84.0 88 3 1/2" 3 1/2" 25.0 106.0 123.0 88.0 78.0
84.0 94.0 100 4" 4" 25.0 116.0 135.0 98.0 87.0
C
DFA
B
E
Check Nut
Entry
Seal Ring
Nipple
Entry Part
Inner
Seal Ring
Armour
Clamping
Cone
Armour
Clamping
Ring
Main
Gland Body
Compression
Nut
Outer
Seal Ring
Tolerance ± 1mm
Material : Brass
Plating : Nickle Plated
Entry Threads : BSC Standard
(Metric / NPT also available)
Sealing Rubber Ring : Natural
Technical Data:
Application:
Used in normal climatic condition for armoured
& unarmoured cables.
TM
Double Compression Medium Duty Cable Glands
16. Flange Type Cable Glands are made out of brass castings and are
machined accurately to the required sizes. These glands are suitable
for armoured cables and are called mechanical glands hence suitable
for outdoor application.
The gland comprises of brass body ( flange type oval shape ) and
plate clamped with galvanised mild steel studs and nuts for clamping
the armour. Tapered cone and nut are provided for termination of
cable.
The cone and body taper is designed for giving a firm grip to the
armour of the cable.
Size
E L Suitable Cable
Dia. Length Overall Dia.
Code Ø mm mm From To
FL 5 15.0 13.0 12.0 16.5
FL 4 19.0 13.0 15.0 19.0
FL 3 19.5 13.0 18.5 20.5
FL 2 25.0 16.5 20.5 24.5
FL 1 31.0 15.5 24.0 30.0
FL 11 31.0 15.0 29.5 34.0
FL 0 37.5 21.0 32.5 35.0
FL 00 37.5 20.0 34.5 38.0
FL 38 42.0 21.5 37.0 42.0
FL 001 49.0 20.5 40.5 44.0
FL 002 53.5 21.5 43.5 52.0
FL 003 60.0 23.0 51.0 58.0
FL 0033 65.0 25.5 56.5 67.0
FL 004 75.0 22.5 66.0 76.0
FL 005 99.0 22.5 75.0 83.0
Page 12
E
L
Gland
Plate
Gland
Body
Check Nut
M.S. Nut
M.S. Stud
Taper Cone
Tolerance ± 1mm
Material : Brass
Finish : Brass
Entry Threads : ET / BSC
Technical Data:
Application:
Generally for armoured cable and outdoor use.
TM
Flange Type Cable Glands
17. Page 13
E1W Type Cable Glands Marine Type Cable Glands
Alco Type Cable Glands
A1/A2 Type Cable GlandsBW Type Cable Glands
CW Type Cable Glands
Wiping GlandsPG Type Cable Glands
TM
Other Types of Cable Glands
18. Material : Brass (IS - 319) Standard
Plating : Nickle Plated - Standard
(Chrome also available)
Threads : BSC - Standard
(PG / Metric / NPT / BSP also available)
Application : Used to prevent unauthorised removal.
Size : 3/4", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3"
Tamper Proof Stopping Plug
Page 14
Material : Brass (IS - 319) Standard
Plating : Nickle Plated - Standard
(Chrome also available)
Threads : BSC - Standard
(PG / Metric / NPT / BSP also available)
Application : Used in normal climatic condition.
Size : 3/4", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3"
Weather Proof Stopping Plug
Material : Brass (IS - 319) Standard
(Al. / M.S. / S.S. also available)
Plating : Nickle Plated - Standard
(Chrome also available)
Threads : BSC - Standard
(PG / Metric / NPT / BSP also available)
Sealing Rubber Ring : Neoprene
Ref. Standard : IS 2148 : 2004
Ingress Protection : IP 65 as per IS 12063 - 1987
Application : Used in flammable gas vapour area.
(Group I, IIA & IIB)
Size (MCS) : 3/4", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3"
Flame Proof Stopping Plug
unused entries of an electrical equipments without revoking
existing certification. The range covers three design types:
Material : Brass (IS - 319) Standard
Plating : Nickle Plated - Standard
(Chrome also available)
Threads : BSC - Standard
(PG / Metric / NPT / BSP also available)
Application : Used in normal climatic condition.
dissimilar thread forms or sizes.
TM
Accessories
Stopping Plug
GIE Range of Stopping plugs are designed to close any
Adaptor
GIE Adaptors provide a means of connection between
19. Material : Brass (IS - 319) Standard
Plating : Nickle Plated - Standard
(Chrome also available)
Threads : BSC - Standard
(PG / Metric / NPT / BSP also available)
Application : Used in normal climatic condition.
Size : 1" x 3/4", 1 1/4" x 1", 1 1/2" x 1 1/4",
2" x 1 1/2", 2 1/2" x 2" , 3" x 2 1/2"
Weather Proof Reducer
Page 15
diameter of an enclosure to accept a gland or fitting with a
smaller thread. The range covers two design types:
Material : Brass
Plating : Nickle Plated
Application : Used with cable gland, adaptor &
reducer to provide a means of conneting
a flexible earth bond.
and Enclosure.
Material : PVC
Application : Minimises the risk of dirt or foreign
substances gathering on the cable gland
body and / or point of cable to the gland
interface.
as additional protection against weather conditions and
corrosion.
Material : Brass (IS - 319) Standard
(Al. / M.S. / S.S. also available)
Plating : Nickle Plated - Standard
(Chrome also available)
Threads : BSC - Standard
(PG / Metric / NPT / BSP also available)
Sealing Rubber Ring : Neoprene
Ref. Standard : IS 2148 : 2004
Ingress Protection : IP 65 as per IS 12063 - 1987
Application : Used in flammable gas vapour area.
(Group I, IIA & IIB)
Size (MCR) : 1" x 3/4", 1 1/4" x 1", 1 1/2" x 1 1/4",
2" x 1 1/2", 2 1/2" x 2" , 3" x 2 1/2"
Flame Proof Reducer
TM
Accessories
Reducer
GIE Reducers effectively reduce the threaded entry
Earth Tag
GIE Earth Tag ensures earthing continuity between Gland
PVC Shroud
GIE PVC Shroud are used for covering the Cable Glands
20. For Unarmoured Single Core Power Cables Type AYY 650 / 1100 V
Single Compression TypeCable Specifications Double Compression Type
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
No. Approx. Size Inches Size Code mm Size Code Size Code Inches Size Inches
1 x 4 8.3 3/8" 5/8" SCG 1 16 MCW 01SS MCF 01SS 3/4" 3/8" 5/8"
1 x 6 8.8 3/8" 5/8" SCG 1 16 MCW 01SS MCF 01SS 3/4" 3/8" 5/8"
1 x 10 9.7 1/2" 5/8" SCG 1 16 MCW 01SS MCF 01SS 3/4" 1/2" 5/8"
1 x 16 11.5 5/8" 5/8" SCG 2 16 MCW 01S MCF 01S 3/4" 5/8" 3/4"
1 x 25 12.5 3/4" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 3/4" 3/4"
1 x 35 14.0 3/4" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 3/4" 3/4"
1 x 50 15.5 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 3/4" 3/4"
1 x 70 17.0 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 7/8" 3/4"
1 x 95 19.5 1" 1" SCG 5 25 MCW 02 MCF 02 1" 7/8" 3/4"
1 x 120 21.5 1 1/8" 1 1/8" SCG 7 32 MCW 03A MCF 03A 28 mm 1" 1"
1 x 150 23.5 1 1/8" 1 1/8" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/8" 1 1/8"
1 x 185 25.5 1 1/4" 1 1/4" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
1 x 240 28.5 1 3/8" 1 3/8" SCG 8 40 MCW 05A MCF 05A 1 1/2" 1 3/8" 1 1/2"
1 x 300 32.0 1 1/2" 1 1/2" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
1 x 400 36.0 1 3/4" 1 3/4" SCG 10 50 MCW 07A MCF 07A 42 mm 1 3/4" 2"
1 x 500 40.0 2" 2" SCG 10 50 MCW 08 MCF 08 2" 1 3/4" 2"
1 x 630 45.0 2" 2" SCG 12 63 MCW 09 MCF 09 2" 2" 2"
1 x 800 49.0 2 1/4" 2 1/4" SCG 12 63 MCW 010A MCF 010A 2 1/2" 2 1/4" 2 1/4"
1 x 1000 54.0 2 1/2" 2 1/2" SCG 13 63 MCW 011S MCF 011S 2 1/2" 2 1/2" 2 1/2"
Page 16
TM
Cable Specifications
For Unarmoured Twin Core Power Cables Type AYY 650 / 1100 V
Single Compression Type Double Compression Type
No. Approx. Size Inches Size Code mm Size Code Size Code Inches Size Inches
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
2 x 4 14.0 3/4" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 3/4" 3/4"
2 x 6 15.0 3/4" 3/4" SCG 3 20 MCW 01A MCF 01A 1" 3/4" 3/4"
2 x 10 17.0 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
2 x 16 20.0 1" 1" SCG 5 25 MCW 02 MCF 02 1" 1" 1"
2 x 25 22.0 1 1/8" 1 1/8" SCG 7 32 MCW 03A MCF 03A 28 mm 1 1/8" 1 1/8"
2 x 35 24.0 1 1/4" 1 1/4" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
2 x 50 27.0 1 1/4" 1 1/4" SCG 7 32 MCW 05A MCF 05A 1 1/2" 1 1/4" 1 1/4"
2 x 70 28.5 1 3/8" 1 3/8" SCG 8 40 MCW 05A MCF 05A 1 1/2" 1 3/8" 1 1/2"
2 x 95 32.0 1 3/8" 1 3/8" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
2 x 120 33.0 1 1/2" 1 1/2" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
2 x 150 36.0 1 3/4" 1 3/4" SCG 10 50 MCW 07A MCF 07A 42 mm 1 3/4" 2"
2 x 185 40.0 2" 2" SCG 10 50 MCW 08 MCF 08 2" 1.3/4" 2"
2 x 240 45.0 2" 2" SCG 12 63 MCW 09 MCF 09 2" 2" 2"
2 x 300 50.0 2 1/4" 2 1/4" SCG 12 63 MCW 010A MCF 010A 2 1/2" 2 1/4" 2 1/4"
2 x 400 55.0 2 1/2" 2 1/2" SCG 13 63 MCW 011 MCF 011 2 1/2" 2 1/2" 2 1/2"
2 x 500 62.0 2 3/4" 2 3/4" SCG 14 75 MCW 012 MCF 012 3" 2 3/4" 2 3/4"
2 x 630 69.0 3" 3" SCG 16 82 MCW 013A MCF 013A 3" 3" 3"
Cable Glands Selection Chart
21. Page 17
For Unarmoured Three & Half Core Power Cables Type AYY 650 / 1100 V
Single Compression Type Double Compression Type
No. Approx. Size Inches Size Code mm Size Code Size Code Inches Size Inches
3 1/2x25/16 24.0 1 1/4" 1 1/4" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
3 1/2x35/16 25.0 1 1/4" 1 1/4" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
3 1/2x50/25 29.0 1 3/8" 1 3/8" SCG 8 40 MCW 05A MCF 05A 1 1/2" 1 3/8" 1 1/2"
3 1/2x70/35 33.0 1 1/2" 1 1/2" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
3 1/2x95/50 38.0 1 3/4" 1 3/4" SCG 10 50 MCW 08 MCF 08 2" 1 3/4" 2"
3 1/2x120/70 41.0 2" 2" SCG 10 50 MCW 08 MCF 08 2" 2" 2"
3 1/2x150/70 44.0 2" 2" SCG 11 50 MCW 09 MCF 09 2" 2" 2"
3 1/2x185/95 50.0 2 1/4" 2 1/4" SCG 12 63 MCW 010A MCF 010A 2 1/2" 2 1/4" 2 1/4"
3 1/2x240/120 57.0 2 1/2" 2 1/2" SCG 14 75 MCW 012 MCF 012 3" 2 1/2" 2 1/2"
3 1/2x300/150 63.0 2 3/4" 2 3/4" SCG 14 75 MCW 012 MCF 012 3" 2 3/4" 2 3/4"
3 1/2x400/185 70.0 3" 3" SCG 16 82 MCW 013 MCF 013 3 1/4" 3" 3"
3 1/2x500/240 80.0 3 1/2" 3 1/2" SCG 17 90 MCW 014 MCF 014 3 1/2" 3 1/2" 3 1/2"
3 1/2x630/300 87.0 4" 4" SCG 18 100 MCW 015 MCF 015 4" 4" 4"
Cable Specifications
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
TM
For Unarmoured Three Core Power Cables Type AYY 650 / 1100 V
Single Compression Type Double Compression Type
No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches
Cable Specifications
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
3 x 4 15.0 3/4" 3/4" SCG 3 20 MCW 01A MCF 01A 1" 3/4" 3/4"
3 x 6 16.0 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
3 x 10 17.5 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
3 x 16 21.0 1 1/8" 1 1/8" SCG 5 25 MCW 03A MCF 03A 28 mm 1 1/8" 1 1/8"
3 x 25 22.0 1 1/8" 1 1/8" SCG 7 32 MCW 03A MCF 03A 28 mm 1 1/8" 1 1/8"
3 x 35 23.5 1 1/8" 1 1/8" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/8" 1 1/8"
3 x 50 27.5 1 3/8" 1 3/8" SCG 8 40 MCW 05A MCF 05A 1 1/2" 1 3/8" 1 1/2"
3 x 70 31.0 1 3/8" 1 3/8" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
3 x 95 35.0 1 3/4" 1 3/4" SCG 10 50 MCW 07A MCF 07A 42 mm 1 3/4" 2"
3 x 120 37.0 1 3/4" 1 3/4" SCG 10 50 MCW 08 MCF 08 2" 1 3/4" 2"
3 x 150 41.0 2" 2" SCG 10 50 MCW 08 MCF 08 2" 2" 2"
3 x 185 45.0 2" 2" SCG 12 63 MCW 09 MCF 09 2" 2" 2"
3 x 240 51.5 2 1/2" 2 1/2" SCG 12 63 MCW 010A MCF 010A 2 1/2" 2 1/2" 2 1/2"
3 x 300 58.0 2 3/4" 2 3/4" SCG 14 75 MCW 012 MCF 012 3" 2 3/4" 2 3/4"
3 x 400 65.0 3" 3" SCG 14 75 MCW 012 MCF 012 3" 3" 3"
3 x 500 74.0 3 1/4" 3 1/4" SCG 16 82 MCW 013 MCF 013 3 1/4" 3 1/4" 3 1/4"
3 x 630 79.0 3 1/2" 3 1/2" SCG 17 90 MCW 014 MCF 014 3 1/2" 3 1/2" 3 1/2"
Cable Glands Selection Chart
22. Page 18
For Unarmoured Four Core Power Cables Type AYY 650 / 1100 V
Double Compression TypeSingle Compression Type
No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches
4 x 4 16.0 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
4 x 6 18.0 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
4 x 10 19.0 1" 1" SCG 5 25 MCW 02 MCF 02 1" 1" 1"
4 x 16 23.5 1 1/8" 1 1/8" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/8" 1 1/8"
4 x 25 24.0 1 1/4" 1 1/4" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
4 x 35 27.0 1 1/4" 1 1/4" SCG 7 32 MCW 05A MCF 05A 1 1/2" 1 1/4" 1 1/4"
4 x 50 32.0 1 3/8" 1 3/8" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
4 x 70 36.0 1 3/4" 1 3/4" SCG 10 50 MCW 07A MCF 07A 42 mm 1 3/4" 2"
4 x 95 41.0 2" 2" SCG 10 50 MCW 08 MCF 08 2" 2" 2"
4 x 120 43.0 2" 2" SCG 10 50 MCW 09 MCF 09 2" 2" 2"
4 x 150 48.0 2 1/4" 2 1/4" SCG 12 63 MCW 010A MCF 010A 2 1/2" 2 1/4" 2 1/4"
4 x 185 53.0 2 1/2" 2 1/2" SCG 12 63 MCW 011S MCF 011S 2 1/2" 2 1/2" 2 1/2"
4 x 240 59.0 2 3/4" 2 3/4" SCG 14 75 MCW 012 MCF 012 3" 2 3/4" 2 3/4"
4 x 300 66.0 3" 3" SCG 14 75 MCW 012 MCF 012 3" 3" 3"
4 x 400 74.0 3 1/4" 3 1/4" SCG 16 82 MCW 013 MCF 013 3 1/4" 3 1/4" 3 1/4"
Cable Specifications
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
For Unarmoured 1.5 sq. mm. Multi Core Control Cables Type YY 650 / 1100 V
Single Compression Type Double Compression Type
No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches
2 x 1.5 11.5 1/2" 5/8" SCG 2 16 MCW 01SS MCF 01SS 3/4" 1/2" 5/8"
3 x 1.5 12.0 5/8" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 5/8" 3/4"
4 x 1.5 13.0 3/4" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 3/4" 3/4"
5 x 1.5 14.0 3/4" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 3/4" 3/4"
6 x 1.5 15.0 3/4" 3/4" SCG 3 20 MCW 01A MCF 01A 1" 3/4" 3/4"
7 x 1.5 15.5 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
10 x 1.5 17.0 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
12 x 1.5 17.5 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
14 x 1.5 18.5 1" 1" SCG 5 25 MCW 02 MCF 02 1" 1" 1"
16 x 1.5 19.5 1" 1" SCG 5 25 MCW 02 MCF 02 1" 1" 1"
19 x 1.5 21.0 1 1/8" 1 1/8" SCG 7 32 MCW 03A MCF 03A 28 mm 1 1/8" 1 1/8"
24 x 1.5 24.0 1 1/8" 1 1/8" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/8" 1 1/8"
27 x 1.5 24.5 1 1/8" 1 1/8" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
30 x 1.5 25.5 1 1/4" 1 1/4" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
37 x 1.5 27.0 1 1/4" 1 1/4" SCG 7 32 MCW 05A MCF 05A 1 1/2" 1 1/4" 1 1/4"
44 x 1.5 30.5 1 3/8" 1 3/8" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
52 x 1.5 33.0 1 1/2" 1 1/2" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
61 x 1.5 34.0 1 3/4" 1 3/4" SCG 9 40 MCW 07A MCF 07A 42 mm 1 3/4" 2"
Cable Specifications
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
TM
Cable Glands Selection Chart
23. For Armoured Single Core Power Cables Type AYFY & AYWY 650 / 1100 V
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry Flange
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric Type
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches
1 x 4 12.3 5/8" 3/4" SCG 2 16 FL 5 MCW 01S MCF 01S 3/4" 5/8" 3/4"
1 x 6 12.8 5/8" 3/4" SCG 2 16 FL 5 MCW 01S MCF 01S 3/4" 5/8" 3/4"
1 x 10 13.5 5/8" 3/4" SCG 2 16 FL 5 MCW 01S MCF 01S 3/4" 5/8" 3/4"
1 x 16 15.0 3/4" 3/4" SCG 3 20 FL 5 MCW 01S MCF 01S 3/4" 3/4" 3/4"
1 x 25 16.0 3/4" 3/4" SCG 3 20 FL 5 MCW 01S MCF 01S 3/4" 3/4" 3/4"
1 x 35 17.0 7/8" 3/4" SCG 4 20 FL 5 MCW 01 MCF 01 3/4" 3/4" 3/4"
1 x 50 19.0 1" 1" SCG 5 25 FL 4 MCW 02 MCF 02 1" 1" 1"
1 x 70 20.0 1" 1" SCG 5 25 FL 3 MCW 02 MCF 02 1" 1" 1"
1 x 95 22.0 1 1/8" 1 1/8" SCG 6 25 FL 2 MCW 03 MCF 03 1" 1" 1"
1 x 120 24.0 1 1/8" 1 1/8" SCG 6 25 FL 2 MCW 04 MCF 04 1" 1 1/8" 1 1/8"
1 x 150 25.0 1 1/8" 1 1/8" SCG 6 25 FL 1 MCW 04 MCF 04 1" 1 1/8" 1 1/8"
1 x 185 27.0 1 1/4" 1 1/4" SCG 7 32 FL 1 MCW 05 MCF 05 1 1/4" 1 1/4" 1 1/4"
1 x 225 30.0 1 3/8" 1 3/8" SCG 8 40 FL 11 MCW 05 MCF 05 1 1/4" 1 3/8" 1 1/2"
1 x 240 33.0 1 3/8" 1 3/8" SCG 8 40 FL 11 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
1 x 300 35.0 1 1/2" 1 1/2" SCG 9 50 FL 00 MCW 07 MCF 07 1 1/2" 1 1/2" 1 1/2"
1 x 400 39.0 1 3/4" 1 3/4" SCG 10 50 FL 38 MCW 08 MCF 08 2" 1 3/4" 2"
1 x 500 41.0 1 3/4" 1 3/4" SCG 10 50 FL 001 MCW 08 MCF 08 2" 1 3/4" 2"
1 x 630 45.0 2" 2" SCG 11 50 FL 002 MCW 09 MCF 09 2" 2" 2"
1 x 800 52.0 2 1/4" 2 1/4" SCG 12 63 FL 003 MCW 010 MCF 010 2" 2 1/4" 2 1/4"
1 x 1000 55.0 2 1/2" 2 1/2" SCG 13 63 FL 003 MCW 011 MCF 011 2 1/2" 2 1/2" 2 1/2"
Single Compression Type Double Compression TypeCable Specifications
Page 19
For Unarmoured 2.5 sq. mm. Multi Core Control Cables Type YY 650 / 1100 V
Single Compression Type Double Compression Type
No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches
2 x 2.5 13.0 5/8" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 5/8" 3/4"
3 x 2.5 13.5 3/4" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 3/4" 3/4"
4 x 2.5 14.5 3/4" 3/4" SCG 3 20 MCW 01S MCF 01S 3/4" 3/4" 3/4"
5 x 2.5 15.5 3/4" 3/4" SCG 3 20 MCW 01A MCF 01A 1" 3/4" 3/4"
6 x 2.5 17.0 1" 1" SCG 5 25 MCW 01A MCF 01A 1" 1" 1"
7 x 2.5 17.5 1" 1" SCG 5 28 MCW 01A MCF 01A 1" 1" 1"
10 x 2.5 19.5 1" 1" SCG 5 25 MCW 02 MCF 02 1" 1" 1"
12 x 2.5 20.5 1" 1" SCG 5 25 MCW 02 MCF 02 1" 1" 1"
14 x 2.5 22.0 1 1/8" 1 1/8" SCG 7 32 MCW 03A MCF 03A 28 mm 1 1/8" 1 1/8"
16 x 2.5 23.0 1 1/8" 1 1/8" SCG 7 32 MCW 03A MCF 03A 28 mm 1 1/8" 1 1/8"
19 x 2.5 24.0 1 1/8" 1 1/8" SCG 7 32 MCW 04A MCF 04A 1 1/4" 1 1/4" 1 1/4"
24 x 2.5 28.0 1 3/8" 1 3/8" SCG 8 40 MCW 05A MCF 05A 1 1/2" 1 3/8" 1 1/2"
27 x 2.5 28.5 1 3/8" 1 3/8" SCG 8 40 MCW 05A MCF 05A 1 1/2" 1 3/8" 1 1/2"
30 x 2.5 29.5 1 3/8" 1 3/8" SCG 8 40 MCW 05A MCF 05A 1 1/2" 1 3/8" 1 1/2"
37 x 2.5 33.0 1 1/2" 1 1/2" SCG 8 40 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
44 x 2.5 35.0 1 3/4" 1 3/4" SCG 10 50 MCW 07A MCF 07A 42 mm 1 3/4" 2"
52 x 2.5 37.0 1 3/4" 1 3/4" SCG 10 50 MCW 08 MCF 08 2" 1 3/4" 2"
61 x 2.5 39.0 2" 2" SCG 10 50 MCW 08 MCF 08 2" 2" 2"
Cable Specifications
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
TM
Cable Glands Selection Chart
24. For Armoured Three Core Power Cables Type AYFY & AYWY 650 / 1100 V
No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches
3 x 4 18.0 1" 1" SCG 5 25 FL 4 MCW 01 MCF 01 3/4" 3/4" 3/4"
3 x 6 19.5 1" 1" SCG 5 25 FL 3 MCW 02 MCF 02 1" 7/8" 3/4"
3 x 10 21.0 1" 1" SCG 5 25 FL 3 MCW 03 MCF 03 1" 1" 1"
3 x 16 23.5 1 1/8" 1 1/8" SCG 6 25 FL 2 MCW 04 MCF 04 1" 1 1/8" 1 1/8"
3 x 25 24.0 1 1/8" 1 1/8" SCG 6 25 FL 1 MCW 04 MCF 04 1" 1 1/8" 1 1/8"
3 x 35 25.5 1 1/4" 1 1/4" SCG 7 32 FL 1 MCW 04 MCF 04 1" 1 1/8" 1 1/8"
3 x 50 29.0 1 3/8" 1 3/8" SCG 8 40 FL 1 MCW 05 MCF 05 1 1/4" 1 1/4" 1 1/4"
3 x 70 33.0 1 1/2" 1 1/2" SCG 9 40 FL 0 MCW 06 MCF 06 1 1/2" 1 1/2" 1 1/2"
3 x 95 37.0 1 3/4" 1 3/4" SCG 9 40 FL 00 MCW 07 MCF 07 1 1/2" 1 3/4" 2"
3 x 120 39.0 1 3/4" 1 3/4" SCG 10 50 FL 38 MCW 08 MCF 08 2" 1 3/4" 2"
3 x 150 43.0 2" 2" SCG 11 50 FL 001 MCW 09 MCF 09 2" 2" 2"
3 x 185 47.0 2 1/4" 2 1/4" SCG 11 50 FL 002 MCW 010 MCF 010 2" 2 1/4" 2 1/4"
3 x 240 53.0 2 1/2" 2 1/2" SCG 12 63 FL 003 MCW 011S MCF 011S 2 1/2" 2 1/2" 2 1/2"
3 x 300 59.0 2 3/4" 2 3/4" SCG 13 63 FL 003 MCW 011 MCF 011 2 1/2" 2 3/4" 2 3/4"
3 x 400 66.0 3" 3" SCG 14 75 FL 0033 MCW 012 MCF 012 3" 3" 3"
3 x 500 76.0 3 1/4" 3 1/4" SCG 16 82 FL 004 MCW 01 MCF 013 3 1/4" 3 1/4" 3 1/4"
Single Compression Type Double Compression TypeCable Specifications
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry Flange
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric Type
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
For Armoured Twin Core Power Cables Type AYFY & AYWY 650 / 1100 V
Cores & Cross Overall Dia. Medium
Nipple Entry Heavy Duty
Nipple Entry Flange
Weather Proof Flame Proof Nipple Entry
Medium
Nipple Entry
for (SCG) as per (MCW) as per (MCF) as per for for
Sectional Area of Cable Duty
Medium Duty IS 12943
in Metric Type
BS 6121 IS 2148 WP. & FLP.
Duty
Medium Duty
No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches
Single Compression Type Double Compression TypeCable Specifications
2 x 4 17.5 3/4" 3/4" SCG 4 20 FL 4 MCW 01 MCF 01 3/4" 3/4" 3/4"
2 x 6 18.5 7/8" 3/4" SCG 5 25 FL 4 MCW 01 MCF 01 3/4" 3/4" 3/4"
2 x 10 20.0 1" 1" SCG 5 25 FL 3 MCW 02 MCF 02 1" 1" 1"
2 x 16 22.5 1" 1" SCG 5 25 FL 2 MCW 03 MCF 03 1" 1" 1"
2 x 25 25.0 1 1/8" 1 1/8" SCG 6 25 FL 1 MCW 04 MCF 04 1" 1 1/8" 1 1/8"
2 x 35 27.0 1 1/4" 1 1/4" SCG 7 32 FL 1 MCW 05 MCF 05 1 1/4" 1 1/4" 1 1/4"
2 x 50 29.0 1 3/8" 1 3/8" SCG 8 40 FL 11 MCW 05 MCF 05 1 1/4" 1 3/8" 1 1/2"
2 x 70 31.0 1 3/8" 1 3/8" SCG 8 40 FL 11 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
2 x 95 33.0 1 3/8" 1 3/8" SCG 8 40 FL 11 MCW 06 MCF 06 1 1/2" 1 3/8" 1 1/2"
2 x 120 34.0 1 1/2" 1 1/2" SCG 9 40 FL 11 MCW 07 MCF 07 1 1/2" 1 1/2" 1 1/2"
2 x 150 38.0 1 1/2" 1 1/2" SCG 9 40 FL 00 MCW 08 MCF 08 2" 1 3/4" 2"
2 x 185 41.0 1 3/4" 1 3/4" SCG 10 50 FL 001 MCW 08 MCF 08 2" 1 3/4" 2"
2 x 240 46.0 2" 2" SCG 11 50 FL 002 MCW 09 MCF 09 2" 2" 2"
2 x 300 51.0 2 1/4" 2 1/4" SCG 12 63 FL 003 MCW 010 MCF 010 2" 2 1/4" 2 1/4"
2 x 400 57.0 2 1/2" 2 1/2" SCG 13 63 FL 003 MCW 011 MCF 011 2 1/2" 2 1/2" 2 1/2"
Page 20
TM
Cable Glands Selection Chart
28. For further inquiries contact:
We reserve the right to make technical changes without notice. While we have done our best to ensure the accuracy of catalogue data, we take no responsibility for printing or other errors.
SURYODAY ENTERPRISE
Mob : +91 9099 408448 Web : www.suryodayent.co.in
www.suryodayent.com
Office:
K1, 74/7, G.I.D.C., Udyognagar, Shanker Tekri,
Jamnagar -361004, Gujarat (INDIA).
Phone : +91-288-2560764 E-mail : kamaniashish@gmail.com