SlideShare uma empresa Scribd logo
1 de 24
Baixar para ler offline
TI00105D/06/EN/13.11
71136725
Technical Information
Proline Prosonic Flow 91W
Ultrasonic Flow Measuring System
Flowrate measurement for standard applications with
drinking water and process water
Applications
The sensors are perfectly suited for the non-contact
measurement of pure or slightly contaminated liquids,
regardless of the pressure or electrical conductivity.
• Suitable for pipe diameters in the range
DN 15 to 2000 (½" to 80")
• Can be used with all metal and plastic pipes lined or
unlined
• Ideal solution for applications with water, e.g. drinking
water, industrial water, saltwater, deionized water,
cooling water and heating water
• Perfectly suitable for
– subsequent mounting
– flow monitoring
– improving measuring points
Features and benefits
The Prosonic Flow ultrasonic clamp-on system allows
accurate and cost-effective flow measurement from
outside the pipe and without the need to interrupt the
process. The flow measurement is bidirectional and
causes no pressure loss.
• Easy, safe and menu-guided sensor mounting ensures
precise measuring results
• Long-term system integrity thanks to robust sensor
and industrial mounting kit design
• Automatic frequency scan for optimized installation
and maximum measuring performance
• IP 68 for pipes under water
• Remote configuration using Endress+Hauser's
FieldCare software
Proline Prosonic Flow 91W
2 Endress+Hauser
Table of contents
Function and system design. . . . . . . . . . . . . . . . . . . . . 3
Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Measuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Sensor selection and arrangement . . . . . . . . . . . . . . . . . . . . . . . . . 5
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operable flow range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Low flow cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Measuring unit electrical connection . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting the connecting cable . . . . . . . . . . . . . . . . . . . . . . . . . 8
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cable-specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Performance characteristics. . . . . . . . . . . . . . . . . . . . 10
Reference operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operating conditions: installation . . . . . . . . . . . . . . . 11
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Connection cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Operating conditions: environment . . . . . . . . . . . . . . 12
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Shock and vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operating conditions: process . . . . . . . . . . . . . . . . . . 13
Medium temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Medium pressure range (nominal pressure) . . . . . . . . . . . . . . . . . 13
Pressure loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Energy Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 14
Design, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Human interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Display elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Operating elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Language group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Certificates and approvals . . . . . . . . . . . . . . . . . . . . . 19
CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
C-Tick mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Other standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Ordering information. . . . . . . . . . . . . . . . . . . . . . . . . 19
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Communication-specific accessories . . . . . . . . . . . . . . . . . . . . . . 21
Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Registered trademarks. . . . . . . . . . . . . . . . . . . . . . . . 23
Proline Prosonic Flow 91W
Endress+Hauser 3
Function and system design
Measuring principle The measuring system operates on the principle of transit time difference. In this measurement method,
acoustic (ultrasonic) signals are transmitted between two sensors. The signals are sent in both directions,
i.e. the sensor in question works as both a sound transmitter and a sound receiver.
As the propagation velocity of the waves is less when the waves travel against the direction of flow than along
the direction of flow, a transit time difference occurs. This transit time difference is directly proportional to the
flow velocity.
A0013117
Principle of the transit time difference measurement method
Q = v · A
a Sensor
b Sensor
Q Volume flow
v Flow velocity (v & t )
t Transit time difference (t = ta – tb)
A Pipe cross-sectional area
The measuring system calculates the volume flow of the fluid from the measured transit time difference and
the pipe cross-sectional area. In addition to measuring the transit time difference, the system simultaneously
measures the sound velocity of the fluid. This additional measured variable can be used to distinguish different
fluids or as a measure of product quality.
The measuring device can be configured onsite to suit the specific application using Quick Setup menus.
bQ
ta
a
tb
Proline Prosonic Flow 91W
4 Endress+Hauser
Measuring The measuring system consists of one transmitter and two sensors. Different versions are available depending
on the specific requirements.
The transmitter is used both to control the sensors and to prepare, process and evaluate the measuring signals,
and to convert the signals to a desired output variable.
The sensors work as sound transmitters and sound receivers. Depending on the application and version, the
sensors can be arranged for measurement via one or two traverses  ä 5.
Transmitter
Mounting accessories
The requisite mounting distances must be determined for the sensors. Information on the fluid, the pipe
material used and the exact pipe dimensions is needed to determine these values. The values for the sound
velocity of the following fluids, pipe materials and lining materials are stored in the transmitter:
Prosonic Flow 91 W Field Housing
A0006022
Prosonic Flow W Prosonic Flow W
DN 15 to 65 (½" to 2½")
A0011484
DN 50 to 4000 (2" to 160")
A0013475
Fluid Pipe material Lining
• Water
• Sea water
• Distilled water
• Ammonia
• Alcohol
• Benzene
• Bromide
• Ethanol
• Glycol
• Kerosene
• Milk
• Methanol
• Toluene
• Lube oil
• Fuel Oil
• Petrol
• Carbon steel
• Ductile Iron
• Stainless steel
• Alloy C
• PVC
• PE
• LDPE
• HDPE
• PVDF
• PA
• PP
• PTFE
• Glass pyrex
• Mortar
• Rubber
• Tar Epoxy
Es
c
Proline Prosonic Flow 91W
Endress+Hauser 5
Sensor selection and
arrangement
The sensors can be arranged in two ways:
• Mounting arrangement for measurement via one traverse:
the sensors are located on opposite sides of the pipe.
• Mounting arrangement for measurement via two traverses:
the sensors are located on the same side of the pipe.
A0005728
Sensor mounting arrangement (top view)
1 Mounting arrangement for measurement via one traverse
2 Mounting arrangement for measurement via two traverses
Recommendations
The number of traverses required depends on the sensor type, the nominal diameter and the thickness of the
pipe wall. We recommend the following types of mounting:
1 2
Sensor Type Nominal Diameter Sensor Frequency Sensor ID Type of Mounting 1)
Prosonic Flow W
DN 15 to 65 (½" to 2 ½") 6 MHz W-CL-6F 2 traverses 3)
DN 80 (3") 2 MHz W-CL-2F 2 traverses
DN 100 to 300 (4" to 12") 2 MHz (or 1 MHz)
W-CL-2F
W-CL-1F
2 traverses 2)
DN 300 to 600 (12" to 24") 1 MHz (or 2 MHz)
W-CL-1F
W-CL-2F
2 traverses 2)
DN 650 to 2000 (26" to 80") 1 MHz (or 0.5 MHz)
W-CL-1F
W-CL-05F
1 traverse 2)
1) The installation of clamp-on sensors is principally recommended in the 2 traverse type installation. This type of
installation allows the easiest and most comfortable type of mounting. However, in certain applications a 1 traverse
installation may be preferred:
• Certain plastic pipes with wall thickness > 4 mm (0.16 in)
• Lined pipes
• Applications with fluids with high acoustic damping
2)
0.5 MHz sensors are also recommended for applications with composite material pipes such as GRP and may be
recommended for certain lined pipes, pipes with wall thickness >10 mm (0.4 in), or applications with media with
high acoustic damping. In addition, for these applications we principally recommend mounting the W sensors in
a 1 traverse configuration.
3)
6 MHz sensors are recommended for applications where flow velocity is < 10 m/s (32.8 Hz/s)
Proline Prosonic Flow 91W
6 Endress+Hauser
Input
Measured variable Flow velocity (differential delay proportional to flow velocity)
Measuring range Typically v = 0 to 15 m/s (0 to 50 ft/s) at the specified measuring accuracy
Operable flow range Over 150 : 1
Output
Output signal Current output:
• Galvanically isolated
• Full scale value adjustable
• Temperature coefficient: typ. 2 μA/°C, resolution: 1.5 μA
• Active: 4 to 20 mA, RL < 700 (for HART: RL  250 )
Pulse/status output:
• Galvanically isolated
• Open collector
• 30 V DC / 250 mA
• Passive
• Can be configured as:
– Pulse output: pulse value and pulse polarity can be selected, max. pulse width adjustable (5 to 2000 ms),
pulse frequency max. 100 Hz
– Status output: for example, can be configured for error messages, empty pipe detection, flow recognition,
limit value
Signal on alarm • Current output  failsafe mode selectable.
• Pulse/frequency output  failsafe mode selectable
Load See “Output signal”
Low flow cutoff Switching point for the low flow freely selectable.
Galvanic isolation All circuits for inputs, outputs, and power supply are galvanically isolated from each other.
Proline Prosonic Flow 91W
Endress+Hauser 7
Power supply
Measuring unit electrical
connection
a0005838
Connecting the transmitter (Aluminium-Fieldhousing).
cable cross-section: max. 2.5 mm(AWG 13)
a Cover
b Cable for power supply: 85 to 260 V AC, 20 to 55 V AC, 16 to 62 V DC
c Terminal for power supply:
d Terminal for power supply: Nr. 1–2 (terminal assignment)
e Signal cable
f Ground terminal für signal cable
g Terminal connector for signal cable: Nr. 24–27 (terminal assignment)
h Service connector
i Ground terminal for potential matching
Terminal assignment Prosonic Flow 91W
e b
2127
–
25
–
26
+
24
+ L1
(L+)
N
(L-)
e
g
b
d
h
cf
b
a
e
i
Order variant Terminal No. (inputs/outputs)
24 (+)/25 (–) 26 (+)/27 (–) 1 (L1/L+) /2 (N/L–)
Fixed communication boards (fixed assignment)
91***-***********A Pulse output HART current output Power supply
Functional values see "Output signal" see "supply voltage"
Proline Prosonic Flow 91W
8 Endress+Hauser
Connecting the connecting
cable
Connection sensor cable in the electronics compartment
A0015907
a, b Sensor connection cable
c Cable gland holder
d Cable gland
Supply voltage Transmitter
85 to 260 V AC, 45 to 65 Hz
20 to 55 V AC, 45 to 65 Hz
16 to 62 V DC
Sensor
Powered by the transmitter
Cable entry Power supply and signal cables (inputs/outputs)
• Cable entry M20 × 1.5 (8 to 12 mm; 0.31 to 0.47 in)
• Cable gland for cables, 6 to 12 mm ( 0.24" to 0.47")
• Thread for cable entries ½" NPT, G ½"
Connection cable (sensor /transmitter)
Cable glands for one multicore connection cable (1 ×  8 mm) per cable entry
• Cable gland M20 × 1.5
• Thread for cable entries ½" NPT, G ½"
Connection cable (sensor /transmitter)
Cable glands for two single core connection cable (2 ×  4 mm) per cable entry
• Cable gland M20 × 1.5
• Thread for cable entries ½" NPT, G ½"
The Prosonic Flow W DN 15 to 65 (½ to 2½") is grounded via the cable gland.
a0016008
Cable gland for one multicore connection cable (1 ×8 mm /0.31 in) per cable entry
a b
d
c
Proline Prosonic Flow 91W
Endress+Hauser 9
A0008152
Cable gland for two connection cables (2 × Q 4 mm/0.16") per cable entry
Cable-specification Only use the connection cable supplied by Endress+Hauser. Different versions of the connecting cables are
available  ä 21.
Prosonic Flow
• Cable material:
– Prosonic Flow 91W (DN 50 to 4000/ 2" to 160") PVC (standard) or optional PTFE
– Prosonic Flow 91W (DN 15 to 65 / ½" to 2½") TPE-V
• Cable length:
– For use in a non hazardous zone: 5 to 60 m (16.4 to 196.8 ft)
! Note!
To ensure correct measuring results, route the connection cable well clear of electrical machines and switching
elements.
power consumption 85 to 250 V AC: <12 VA (incl. measuring sensor)
20 to 28 V AC: <7 VA (incl. measuring sensor)
11 to 40 V DC: <5 W (incl. measuring sensor)
Power supply failure Lasting min. 1 power cycle
HistoROM/T-DAT save measuring system data if the power supply fails
Potential equalization For potential equalization, no special measures are necessary.
Proline Prosonic Flow 91W
10 Endress+Hauser
Performance characteristics
Reference operating
conditions
• Fluid temperature: +28 °C ± 2 K
• Ambient temperature: +22 °C ± 2 K
• Warm-up period: 30 minutes
Installation:
• Sensor and transmitter grounded.
• The measuring sensors are mounted correctly.
Maximum measured error Measured error
The measured error depends on a number of factors. A distinction is made between the measured error of the
device (Prosonic Flow 91 = 0.5 % of the measured value) and an additional installation-specific measured error
(typically 1.5 % of the measured value) that is independent of the device.
The installation-specific measured error depends on the installation conditions on site, such as the nominal
diameter, wall thickness, real pipe geometry, fluid etc. The sum of the two measured errors is the measured
error at the measuring point.
A0011347
Example of the measured error in a pipe with a nominal diameter DN > 200 (8")
a Measured error of the device (0.5 % o.r. ± 3 mm/s
b Measured error due to installation conditions (typically 1.5 % o.r.)
c Measured error at the measuring point: 0.5 % o.r. ± 3 mm/s + 1.5 % o.r. = 2 % o.r. ± 3 mm/s.
Measured error at the measuring point
The measured error at the measuring point is made up of the measured error of the device
(0.5 % o.r.) and the measured error resulting from the installation conditions on site.
Given a flow velocity > 0.3 m/s (1 ft/s) and a Reynolds number > 10000, the following are typical error limits:
o.r. = of reading
Measurement Report
If required, the device can be supplied with a measurement report. To certify the performance of the device,
a measurement is performed under reference conditions. Here, the sensors are mounted on a pipe with a
nominal diameter of DN 100 (4").
The measurement report guarantees the following error limits of the device
(at a flow velocity > 0.3 m/s (1 ft/s) and a Reynolds number > 10000):
o.r. = of reading
Repeatability Max. ± 0.3 % for flow velocity > 0.3 m/s (1 ft/s)
0
0.5
2.0
3.5
%
m/s2 4 6 8 10 12
b
c
a
Nominal
diameter
Device error limits +
Installation-specific
error limits (typical)

Error limits at the measuring point
(typical)
DN 15 (½") ±0.5 % o.r. ± 5 mm/s + ±2.5 % o.r.  ±3 % o.r. ± 5 mm/s
DN 25 to 200 ±0.5 % o.r. ± 7.5 mm/s + ±1.5 % o.r.  ±2 % o.r. ±7.5 mm/s
> DN 200 ±0.5 % o.r. ± 3 mm/s + ±1.5 % o.r.  ±2 % o.r. ± 3 mm/s
Nominal diameter Guaranteed error limits of the device Guaranted error limits of the device
Prosonic Flow W DN 15 (½"), DN 25 (1"), DN 40 (1½"), DN 50 (2") ±0.5 % o.r. ± 5 mm/s
Prosonic Flow W DN 100 (4") ±0.5 % o.r. ± 7.5 mm/s
Proline Prosonic Flow 91W
Endress+Hauser 11
Operating conditions: installation
Installation instructions Mounting location
Correct flow measurement is possible only if the pipe is full. It is preferable to install the sensors in a riser.
! Note!
Entrained air or gas bubbles in the measuring tube can result in an increase in measuring errors.
For this reason, avoid the following mounting locations:
• Highest point of a pipeline. Risk of air accumulating.
• Directly upstream of a free pipe outlet in a vertical pipe. Risk of partial pipe filling.
A0001103
Orientation
Vertical
Recommended orientation with upward direction of flow (View A). With this orientation, entrained solids will
sink and gases will rise away from the sensor when the fluid is stagnant. The piping can be completely drained
and protected against solids buildup.
Horizontal
In the recommended installation range in a horizontal installation position (View B), gas and air collections at
the pipe cover and problematic deposits at the bottom of the pipe have a smaller influence on measurement.
a0001105
A Vertical
B Horizontal
C Recommended installation range max. 120°
A
B
C C
Proline Prosonic Flow 91W
12 Endress+Hauser
Inlet and outlet runs If possible, install the sensor well clear of assemblies such as valves, T-pieces, elbows, etc. If several flow
obstructions are installed, the longest inlet or outlet run must be considered. Compliance with the following
requirements for the inlet and outlet runs is recommended to ensure measuring accuracy.
A0013079
Inlet and outlet runs (top view)
1 Valve (2/3 open)
2 Pump
3 Two pipe bends in different directions
Connection cable Route the cable well clear of electrical machines and switching elements
Cable specification  ä 8
Operating conditions: environment
Ambient temperature range Transmitter
–25 to +60 °C (–13 to +140 °F)
At ambient temperatures below –20 °C (–4 °F) the readability of the display may be impaired.
Install the transmitter at a shady location. Avoid direct sunlight, particularly in warm climatic regions.
Sensor Prosonic Flow W
–20 to +80 °C (–4 to +176 °F)
Optional: 0 to +130 °C (–32 to +265 °F)
It is permitted to insulate the sensors mounted on the pipe.
Connecting cable (sensor/transmitter)
• Standard (TPE-V): –20 to +80 °C (–4 to 175 °F) (multi core, sensor DN 15 to 65 / ½" to 2½") 
• Standard (PVC): –20 to +70 °C (–4 to 158 °F) (single core, sensor DN 50…4000 /2" to 160")
• Optional (PTFE): –40 to +170 °C (–40 to 338 °F) (single core, sensor DN 50…4000 /2" to 160")
• It is permitted to insulate the sensors mounted on the pipes.
• Mount the transmitter in a shady location and avoid direct sunlight, particulary in warm climatic regions.
! Note!

Can be used with the version for 0…130 °C /-32…256 °F.
Storage temperature The storage temperature corresponds to the operating temperature range of the measuring transmitter and the
appropriate measuring sensors and the corresponding sensor cable (see above).
1
2
3
³ 15 x DN ³ 3 x DN
³ 20 x DN
³ 15 x DN
³ 20 x DN
Proline Prosonic Flow 91W
Endress+Hauser 13
Degree of protection Transmitter
IP 67 (NEMA 4X)
Sensors
IP 67 (NEMA 4X)
Optional: IP 68 (NEMA 6P)
Shock and vibration resistance according to IEC 68-2-6
Operating conditions: process
Medium temperature range –20 to +80 °C (–4 to +176 °F)
Optional: 0 to +130 °C (32 to +265 °F)
Medium pressure range
(nominal pressure)
Perfect measurement requires that the static fluid pressure is higher than vapor pressure, to avoid outgasing.
Pressure loss There is no pressure loss.
Energy Measurement The Prosonic Flow 91W Ultrasonic is well suited for making or retrofitting energy measurement for hot or
chilled water systems - often used in conjunction with Endress+Hauser Flow and Energy Manager
RMC621/RMS621.
The quantity of heat is calculated from the process variable for flow and the differential from the feed and return
temperature. Energy Manager can also determine the quantity of heat in water flow from process variable flow
and a single temperature measurement.
Installation of delta heat measurement
• Temperature measurement takes place via two separate sensors which are directly connected to the
Endress+Hauser Energy Manager. (Temperature sensors and Energy Manager supplied separately).
• The Prosonic Flow 91W can be installed on either the hot or cold side of the heat exchanger.
A0013111
Layout for delta heat measurement of hot or chilled water system
Q
Esc
E- +
T1
T2
Proline Prosonic Flow 91W
14 Endress+Hauser
Mechanical construction
Design, dimensions Dimensions field housing
A0006063-ae
Dimensions pipe mounting
a0005819
Esc
E- +
190 (7.48)
178 (7.0)
~150 (~5.9)
113 (4.45)
==
Ø8.6(M8)(0.34)
200(7.87)
150(5.9)
Ø 129 (5.1)
mm (inch)
100 (3.94)
80 (3.15)
52(2.0)
50(1.97)
190 (7.48)
Esc
E- +
A
Esc
E- +
B
80
(3.15)
172.5(6.79)
&185 ( 3.34)&
mm (inch)
Proline Prosonic Flow 91W
Endress+Hauser 15
Prosonic Flow W sensor (DN 15 to 65 / ½" to 2½")
A0011502
Mounting arrangement for measurement via one traverse
Dimensions in SI units
Dimensions in US units
B
A C
EF
D
A B C D E F
72 331 39 28 233 450
All dimensions in [mm]
A B C D E F
2.83 13.03 1.54 1.10 .17 17.72
All dimensions in [inch]
Proline Prosonic Flow 91W
16 Endress+Hauser
Prosonic Flow W sensor (DN50 to 2000 / 2" to 80")
A0011401
Mounting arrangement for measurement via two traverse
Dimensions in SI units
Dimensions in US units
E
A
DB I
C
H
G
F
A B C D E F
56 62 145 111  58 Max. 872
G H
Depends on the measuring point conditions (pipe, fluid etc.).
Dimension "H" can be determined:
• by the transmitter prior to the mounting (Quick Setup or FieldCare)
• when specifying the flowmeter (online (Applicator)
Pipe outer diameter
All dimensions in [mm]
A B C D E F
2.20 2.44 5.71 4.37  2.28 Max. 34.3
G H
Depends on the measuring point conditions (pipe, fluid etc.).
Dimension "H" can be determined:
• by the transmitter prior to the mounting (Quick Setup or FieldCare)
• when specifying the flowmeter (online (Applicator)
Pipe outer diameter
All dimensions in [inch]
Proline Prosonic Flow 91W
Endress+Hauser 17
Prosonic Flow W sensor (DN50 to 2000 / 2" to 80")
A0011155
Mounting arrangement for measurement via one traverse
Dimensions in SI units
Dimensions in US units E
DH
A
B
G
C
F
A B C D E F
56 62 145 111  58 Max. 872
G H
Depends on the measuring point conditions (pipe, fluid etc.).
Dimension "H" can be determined:
• by the transmitter prior to the mounting (Quick Setup or FieldCare)
• when specifying the flowmeter (online (Applicator)
Pipe outer diameter
All dimensions in [mm]
A B C D E F
2.20 2.44 5.71 4.37  2.28 Max. 34.3
G H
Depends on the measuring point conditions (pipe, fluid etc.).
Dimension "H" can be determined:
• by the transmitter prior to the mounting (Quick Setup or FieldCare)
• when specifying the flowmeter (online (Applicator)
Pipe outer diameter
All dimensions in [inch]
Proline Prosonic Flow 91W
18 Endress+Hauser
Weight • Transmitter housing: 2.4 kg (5.2 lb)
• Flowrate measuring sensors W (clamp-on) incl. mounting rail and tensioning bands: 2.8 kg (6.2 lb)
Materials Transmitter
Wall-mounted housing: powder-coated die-cast aluminum
Sensor
• Sensor holder: stainless steel 1.4308/CF-8
• Sensor housing: stainless steel 1.4301/304
• Strapping bands/bracket: stainless steel 1.4301/304
• Sensor contact surfaces: chemically stable plastic
Connecting cable (sensor/transmitter)
• PVC/TPE-V connecting cable
– Cable sheath: PVC/TPE-V
– Cable connector: nickeled brass 2.0401/C38500
Human interface
Display elements • Liquid crystal display: illuminated, two lines each with 16 characters
• Custom configuration for presenting different measured values and status variables
• 1 totalizer
Operating elements Local operation via three operating keys (S, O, F)
Remote operation Operation via HART protocol and FieldCare
Language group English, German, Spanish, Italian, French
Proline Prosonic Flow 91W
Endress+Hauser 19
Certificates and approvals
CE mark The measuring system is in conformity with the statutory requirements of the EC Directives.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
C-Tick mark The measuring system is in conformity with the EMC requirements of the Australian Communications and
Media Authority (ACMA).
Ex approval Information about currently available Ex versions (FM, CSA) can be supplied by your Endress+Hauser Sales
Center on request. All explosion protection data are given in a separate documentation which is available upon
request.
Other standards and
guidelines
• EN 60529
Degrees of protection provided by enclosures (IP code)
• EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use
• IEC/EN 61326
"Emission in accordance with Class A requirements".
Electromagnetic compatibility (EMC requirements).
• ANSI/ISA-S82.01
Safety Standard for Electrical and Electronic Test, Measuring, Controlling and Related
Equipment - General Requirements. Pollution Degree 2, Installation Category II.
• CAN/CSA-C22.2 No. 1010.1-92
Safety Requirements for Electrical Equipment for Measurement and Control and Laboratory Use.
Pollution degree 2
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with analog output
signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics.
Ordering information
The Endress+Hauser service organization can provide detailed ordering information and information on the
order codes on request.
Proline Prosonic Flow 91W
20 Endress+Hauser
Accessories
Various accessories, which can be ordered separately from Endress+Hauser, are available for the transmitter
and the sensor. The Endress+Hauser service organization can provide detailed information on the order codes
on request.
Device-specific accessories
Device-specific accessories
Accessory Description Order code
Sensor W
(DN 15 to 65, (½" to 2½")
Clamp-on version
DN 15 to 65, –20 to +80 °C (½" to 2 ½", –4 to +176 °F), 5.0 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DK9WS - 1*
DK9WS - 3*
DN 15 to 65, 0 to +130 °C (½" to 2 ½", +32 to +266 °F), 5.0 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DK9WS - 2*
DK9WS - 4*
Sensor W
(DN 50 to 4000, (2" to 157")
Clamp-on version
DN 50 to 300, –20 to +80 °C (2" to 12", –4 to +176 °F), 2.0 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DK9WS - B*
DK9WS - N*
DN 100 to 4000, –20 to +80 °C (4" to 160", –4 to +176 °F), 1.0 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DK9WS - A*
DK9WS - M*
DN 100 to 4000, 0 to +130 °C (4" to 160", +32 to +266 °F), 1.0 MHz
• IP 67 / NEMA 4X DK9WS - P*
DN 50 to 300, 0 to +130 °C (2" to 12", +32 to +266 °F), 2.0 MHz
• IP 67 / NEMA 4X DK9WS - S*
DN 100 to 4000, –20 to +80 °C (4" to 160", –4 to +176 °F), 0.5 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DK9WS - R*
DK9WS - T*
Accessory Description Order code
Mounting kit for
aluminum field housing
Mounting kit for wall-mount housing. DK9WM - C
Sensor holder set Prosonic Flow W (DN 15 to 65, ½" to 2½")
• Sensor holder, clamp-on version
Prosonic Flow W (DN 50 to 4000, 2" to 160")
• Sensor holder, fixed retaining nut, clamp-on version
• Sensor holder, detachable retaining nut, clamp on version
DK9SH - 1
DK9SH - A
DK9SH - B
Clamp-on installation set Sensor fastening for Prosonic Flow W
(DN 15 to 65, ½" to 2 ½")
• U-Bolt DN15-32 (½ to 1 ¼")
• Strapping bands DN 40 to 65 (1 ½ to 2 ½")
(DN 50 to 4000, 2" to 160")
• Without sensor fastening
• Strapping bands DN 50 to 200 (2" to 8")
• Strapping bands DN 200 to 600 (8" to 24")
• Strapping bands DN 600 to 2000 (24" to 80")
• Strapping bands DN 2000 to 4000 (80" to 160")
DK9IC - 11*
DK9IC - 21*
DK9IC - A*
DK9IC - B*
DK9IC - C*
DK9IC - D*
DK9IC - E*
• Without mounting tools
• Spacing ruler DN 50 to 200 (2" to 8")
• Spacing ruler DN 200 to 600 (8" to 24")
• Fastener, 1 Traverse DN 50 to 4000 (2" to 160")
DK9IC - *1
DK9IC - *2
DK9IC - *3
DK9IC - *6
Proline Prosonic Flow 91W
Endress+Hauser 21
Communication-specific
accessories
Conduit adapter for
connecting cable
Prosonic Flow W (DN 15 to 65, ½" to 2 ½")
• Conduit adapter incl. cable entry M20 × 1,5
• Conduit adapter incl. cable entry ½" NPT
• Conduit adapter incl. cable entry G ½"
Prosonic Flow W (DN 50 to 4000, 2" to 160")
• Conduit adapter incl. cable entry M20 × 1,5
• Conduit adapter incl. cable entry ½" NPT
• Conduit adapter incl. cable entry G ½"
DK9CB - AA1
DK9CB - AA2
DK9CB - AA3
DK9CB - AB1
DK9CB - AB2
DK9CB - AB3
Connecting cable For sensor DN 15 to 65, ½" to 2 ½"
5 m (16 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
10 m (33 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
15 m (49 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
30 m (98 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
For sensor DN 50 to 4000, 2" to 160"
5 m (16 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
10 m (33 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
15 m (49 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
30 m (98 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
60 m (197 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
DK9SS - AAA
DK9SS - AAB
DK9SS - AAC
DK9SS - AAD
DK9SS - ABA
DK9SS - ABB
DK9SS - ABC
DK9SS - ABD
DK9SS - ABJ
Acoustic coupling fluid • Coupling fluid 0 to 170 °C (+32 to 338 °F), Standard
• Adhesive coupling fluid –40 to +80 °C (–40 to 176 °F)
• Water-soluble coupling fluid –20 to +80 °C (–4 to 176 °F)
• Coupling fluid DDU 19, –20 to +60 °C (–4 to 140 °F)
• Coupling fluid –40 to +100 °C (–40 to 212 °F), Standard,
type MBG2000
DK9CM - 2
DK9CM - 3
DK9CM - 4
DK9CM - 6
DK9CM - 7
Accessory Description Order code
Accessory Description Order code
HART Communicator
Field Xpert SFX 100
Handheld terminal for remote configuration and for obtaining
measured values via the HART current output (4 to 20 mA).
Contact your Endress+Hauser representative for more
information.
SFX100 – *******
Fieldgate FXA320 Gateway for remote interrogation of HART sensors and actuators
via Web browser:
• 2-channel analog input (4 to 20 mA)
• 4 binary inputs with event counter function and frequency
measurement
• Communication via modem, Ethernet or GSM
• Visualization via Internet/Intranet in the Web browser and/or
WAP cellular phone
• Limit value monitoring with alarm signaling via e-mail or SMS
• Synchronized time stamping of all measured values.
FXA320 - *****
Fieldgate FXA520 Gateway for remote interrogation of HART sensors and actuators
via Web browser:
• Web server for remote monitoring of up to 30 measuring points
• Intrinsically safe version [EEx ia]IIC for applications in
hazardous areas
• Communication via modem, Ethernet or GSM
• Visualization via Internet/Intranet in the Web browser and/or
WAP cellular phone
• Limit value monitoring with alarm signaling via e-mail or SMS
• Synchronized time stamping of all measured values
• Remote diagnosis and remote configuration of
connected HART devices
FXA520 - ****
FXA195 The Commubox FXA195 connects intrinsically safe Smart
transmitters with HART protocol to the USB port of a personal
computer. This makes the remote operation of the transmitters
possible with the aid of configuration programs (e.g. FieldCare).
Power is supplied to the Commubox by means of the USB port
FXA195 – *
Proline Prosonic Flow 91W
22 Endress+Hauser
Service-specific accessories Accessory Description Order code
Applicator Software for selecting and planning flowmeters.
The Applicator can be downloaded from the Internet or
ordered on CD-ROM for installation on a local PC.
Contact your Endress+Hauser representative for more
information.
DXA80 - *
Fieldcheck Tester/simulator for testing flowmeters in the field.
When used in conjunction with the "FieldCare" software
package, test results can be imported into a database, printed
out and used for official certification.
Contact your Endress+Hauser representative for more
information.
50098801
FieldCare FieldCare is Endress+Hauser's FDT-based plant asset
management tool. It can configure all intelligent field units
in your system and helps you manage them.
By using the status information, it is also a simple but
effective way of checking their status and condition.
See the product page on the
Endress+Hauser Web site:
www.endress.com
FXA291 Service interface from the measuring device to the PC for
operation via FieldCare.
FXA291 – *
Memograph M graphic
display recorder
The Memograph M graphic display recorder provides
information on all the relevant process variables. Measured
values are recorded correctly, limit values are monitored and
measuring points analyzed. The data are stored in the 256
MB internal memory and also on a DSD card or USB stick.
Memograph M boasts a modular design, intuitive operation
and a comprehensive security concept. The ReadWin®
2000
PC software is part of the standard package and is used for
configuring, visualizing and archiving the data captured.
The mathematics channels which are optionally available
enable continuous monitoring of specific power
consumption, boiler efficiency and other parameters which
are important for efficient energy management.
RSG40-************
Proline Prosonic Flow 91W
Endress+Hauser 23
Documentation
• Flow measurement (FA005D/06)
• Operating Instructions for Prosonic Flow 91 (BA100D/06)
• Supplementary documentation on Ex-ratings: FM, CSA
Registered trademarks
HART®
Registered trademark of HART Communication Foundation, Austin, USA
HistoROM™, T-DAT™, FieldCare®
, Field Xpert™, Fieldcheck®
Registered or registration-pending trademarks of Endress+Hauser Flowtec AG, Reinach, CH
Instruments International
Endress+Hauser
Instruments International AG
Kaegenstrasse 2
4153 Reinach
Switzerland
Tel.+41 61 715 81 00
Fax+41 61 715 25 00
www.endress.com
info@ii.endress.com
TI00105D/06/EN/13.11
71136725
FM+SGML6.0 ProMoDo

Mais conteúdo relacionado

Mais procurados

Mais procurados (20)

Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeterProline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
 
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeterProsonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
 
Electromagnetic flowmeter - Proline promag 10D
Electromagnetic flowmeter - Proline promag 10DElectromagnetic flowmeter - Proline promag 10D
Electromagnetic flowmeter - Proline promag 10D
 
Ultrasonic flowmeter-Proline Prosonic Flow 92F
Ultrasonic flowmeter-Proline Prosonic Flow 92FUltrasonic flowmeter-Proline Prosonic Flow 92F
Ultrasonic flowmeter-Proline Prosonic Flow 92F
 
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring systemProline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
 
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
 
Proline Promag L 800-Electromagnetic Flowmeter
Proline Promag L 800-Electromagnetic FlowmeterProline Promag L 800-Electromagnetic Flowmeter
Proline Promag L 800-Electromagnetic Flowmeter
 
Proline Promag 10L-Electromagnetic Flowmeter
Proline Promag 10L-Electromagnetic FlowmeterProline Promag 10L-Electromagnetic Flowmeter
Proline Promag 10L-Electromagnetic Flowmeter
 
Electromagnetic flowmeter - Proline Promag D 400
Electromagnetic flowmeter - Proline Promag D 400Electromagnetic flowmeter - Proline Promag D 400
Electromagnetic flowmeter - Proline Promag D 400
 
Proline promag 50 l endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 l endress+hauser datasheet-electromagnetic flowmeterProline promag 50 l endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 l endress+hauser datasheet-electromagnetic flowmeter
 
Liquistation csf48 endress+hauser datasheet-automatic stationary sampler
Liquistation csf48 endress+hauser datasheet-automatic stationary samplerLiquistation csf48 endress+hauser datasheet-automatic stationary sampler
Liquistation csf48 endress+hauser datasheet-automatic stationary sampler
 
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
 
Micropilot fmr50 endress+hauser datasheet-free space radar
Micropilot fmr50 endress+hauser datasheet-free space radarMicropilot fmr50 endress+hauser datasheet-free space radar
Micropilot fmr50 endress+hauser datasheet-free space radar
 
Ultrasonic flowmeter-Drinking water, wastewater and process water.
Ultrasonic flowmeter-Drinking water, wastewater and process water.Ultrasonic flowmeter-Drinking water, wastewater and process water.
Ultrasonic flowmeter-Drinking water, wastewater and process water.
 
Fmu90 ti
Fmu90 tiFmu90 ti
Fmu90 ti
 
Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multipl...
Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multipl...Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multipl...
Liquipoint t ftw31 32 endress+hauser datasheet-level limit switch for multipl...
 
Liquiphant m density densitycontroller fml621 endress+hauser datasheet
Liquiphant m density densitycontroller fml621 endress+hauser datasheetLiquiphant m density densitycontroller fml621 endress+hauser datasheet
Liquiphant m density densitycontroller fml621 endress+hauser datasheet
 
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeterProline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 h endress+hauser datasheet-electromagnetic flowmeter
 
Proline promag 10 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 10 w endress+hauser datasheet-electromagnetic flowmeterProline promag 10 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 10 w endress+hauser datasheet-electromagnetic flowmeter
 
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensors
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensorsProsonic s fdu90 endress+hauser datasheet-ultrasonic sensors
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensors
 

Semelhante a Ultrasonic flowmeter-Drinking water and process water

Semelhante a Ultrasonic flowmeter-Drinking water and process water (20)

Dosimag. Electromagnetic Flow Measuring System
Dosimag. Electromagnetic Flow Measuring SystemDosimag. Electromagnetic Flow Measuring System
Dosimag. Electromagnetic Flow Measuring System
 
Ga dat cam bien
Ga dat cam bien Ga dat cam bien
Ga dat cam bien
 
Electromagnetic flowmeter - Proline Promag 10H
Electromagnetic flowmeter - Proline Promag 10HElectromagnetic flowmeter - Proline Promag 10H
Electromagnetic flowmeter - Proline Promag 10H
 
Proline Promag 50L-Electromagnetic Flowmeter
Proline Promag 50L-Electromagnetic FlowmeterProline Promag 50L-Electromagnetic Flowmeter
Proline Promag 50L-Electromagnetic Flowmeter
 
Electromagnetic flowmeter - Proline Promag 55H
Electromagnetic flowmeter - Proline Promag 55HElectromagnetic flowmeter - Proline Promag 55H
Electromagnetic flowmeter - Proline Promag 55H
 
Proline promag 10 l endress+hauser datasheet-electromagnetic flowmeter
Proline promag 10 l endress+hauser datasheet-electromagnetic flowmeterProline promag 10 l endress+hauser datasheet-electromagnetic flowmeter
Proline promag 10 l endress+hauser datasheet-electromagnetic flowmeter
 
Electromagnetic flowmeter - Proline Promag 50H, 53H
Electromagnetic flowmeter - Proline Promag 50H, 53HElectromagnetic flowmeter - Proline Promag 50H, 53H
Electromagnetic flowmeter - Proline Promag 50H, 53H
 
Flowmeter Promag 10W-Electromagnetic-Water and Waste Water
Flowmeter Promag 10W-Electromagnetic-Water and Waste WaterFlowmeter Promag 10W-Electromagnetic-Water and Waste Water
Flowmeter Promag 10W-Electromagnetic-Water and Waste Water
 
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeterProline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
 
Proline promag 10 p endress+hauser datasheet-electromagnetic flowmeter
Proline promag 10 p endress+hauser datasheet-electromagnetic flowmeterProline promag 10 p endress+hauser datasheet-electromagnetic flowmeter
Proline promag 10 p endress+hauser datasheet-electromagnetic flowmeter
 
Proline Promag 10P-Electromagnetic Flowmeter
Proline Promag 10P-Electromagnetic FlowmeterProline Promag 10P-Electromagnetic Flowmeter
Proline Promag 10P-Electromagnetic Flowmeter
 
Ultrasonic Level Measurement-Prosonic T FMU30
Ultrasonic Level Measurement-Prosonic T FMU30Ultrasonic Level Measurement-Prosonic T FMU30
Ultrasonic Level Measurement-Prosonic T FMU30
 
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeterProline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
 
Flowmeter Promag 55S-Electromagnetic-Endress Hauser
Flowmeter Promag 55S-Electromagnetic-Endress HauserFlowmeter Promag 55S-Electromagnetic-Endress Hauser
Flowmeter Promag 55S-Electromagnetic-Endress Hauser
 
Proline Promag L 400-Electromagnetic Flowmeter
Proline Promag L 400-Electromagnetic FlowmeterProline Promag L 400-Electromagnetic Flowmeter
Proline Promag L 400-Electromagnetic Flowmeter
 
Proline Promag P200-Electromagnetic Flowmeter
Proline Promag P200-Electromagnetic FlowmeterProline Promag P200-Electromagnetic Flowmeter
Proline Promag P200-Electromagnetic Flowmeter
 
Flowmeter Promag W 400-Electromagnetic-Water and Waste Water
Flowmeter Promag W 400-Electromagnetic-Water and Waste WaterFlowmeter Promag W 400-Electromagnetic-Water and Waste Water
Flowmeter Promag W 400-Electromagnetic-Water and Waste Water
 
Electromagnetic flowmeter - Proline Promag H 200
Electromagnetic flowmeter - Proline Promag H 200Electromagnetic flowmeter - Proline Promag H 200
Electromagnetic flowmeter - Proline Promag H 200
 
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
Cerabar t pmc131 pmp131 pmp135-endress+hauser datasheet-process pressure meas...
 
Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20
 

Mais de Edress Hauser: Flow Meter, Level, Pressure, Temperature

Mais de Edress Hauser: Flow Meter, Level, Pressure, Temperature (20)

Liquiphant M Density and Density Computer FML621
Liquiphant M Density and Density Computer FML621Liquiphant M Density and Density Computer FML621
Liquiphant M Density and Density Computer FML621
 
Microwave barrier- Soliwave FQR56/FDR56
Microwave barrier- Soliwave FQR56/FDR56Microwave barrier- Soliwave FQR56/FDR56
Microwave barrier- Soliwave FQR56/FDR56
 
Microwave barrier-Soliwave M FQR50 / FDR50
Microwave barrier-Soliwave M FQR50 / FDR50Microwave barrier-Soliwave M FQR50 / FDR50
Microwave barrier-Soliwave M FQR50 / FDR50
 
Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31
 
Level limit switch-Soliswitch FTE30
Level limit switch-Soliswitch FTE30Level limit switch-Soliswitch FTE30
Level limit switch-Soliswitch FTE30
 
Flow indicator for bulk solids-Solimotion FTR20
Flow indicator for bulk solids-Solimotion FTR20Flow indicator for bulk solids-Solimotion FTR20
Flow indicator for bulk solids-Solimotion FTR20
 
Level measurement with Prothermo NMT532
Level measurement with Prothermo NMT532 Level measurement with Prothermo NMT532
Level measurement with Prothermo NMT532
 
High accuracy liquid level measurement-Proservo NMS5
High accuracy liquid level measurement-Proservo NMS5High accuracy liquid level measurement-Proservo NMS5
High accuracy liquid level measurement-Proservo NMS5
 
Conductive Limit Detection-Rod Probe 11263
Conductive Limit Detection-Rod Probe 11263Conductive Limit Detection-Rod Probe 11263
Conductive Limit Detection-Rod Probe 11263
 
FTW360 compact pump protector
FTW360 compact pump protectorFTW360 compact pump protector
FTW360 compact pump protector
 
Conductive-Point level switch for multiple point
Conductive-Point level switch for multiple pointConductive-Point level switch for multiple point
Conductive-Point level switch for multiple point
 
Level limit switch compact design-Liquiphant T FTL20H
Level limit switch compact design-Liquiphant T FTL20HLevel limit switch compact design-Liquiphant T FTL20H
Level limit switch compact design-Liquiphant T FTL20H
 
Vibronic-Point level switch for all kinds of liquids
Vibronic-Point level switch for all kinds of liquidsVibronic-Point level switch for all kinds of liquids
Vibronic-Point level switch for all kinds of liquids
 
Vibronic-Point level switch-Liquiphant M FTL51C
Vibronic-Point level switch-Liquiphant M FTL51CVibronic-Point level switch-Liquiphant M FTL51C
Vibronic-Point level switch-Liquiphant M FTL51C
 
Level limit switch for liquids-Liquiphant T FTL20
Level limit switch for liquids-Liquiphant T FTL20Level limit switch for liquids-Liquiphant T FTL20
Level limit switch for liquids-Liquiphant T FTL20
 
Differential pressure measurement-Level transmiter
Differential pressure measurement-Level transmiterDifferential pressure measurement-Level transmiter
Differential pressure measurement-Level transmiter
 
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
 
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
 
Capacitance level measurement-Liquicap M FMI51, FMI52
Capacitance level measurement-Liquicap M FMI51, FMI52Capacitance level measurement-Liquicap M FMI51, FMI52
Capacitance level measurement-Liquicap M FMI51, FMI52
 
Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44
Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44
Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44
 

Último

Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 

Último (20)

Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Cyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdfCyberprint. Dark Pink Apt Group [EN].pdf
Cyberprint. Dark Pink Apt Group [EN].pdf
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectors
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024
 
Ransomware_Q4_2023. The report. [EN].pdf
Ransomware_Q4_2023. The report. [EN].pdfRansomware_Q4_2023. The report. [EN].pdf
Ransomware_Q4_2023. The report. [EN].pdf
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfRising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUKSpring Boot vs Quarkus the ultimate battle - DevoxxUK
Spring Boot vs Quarkus the ultimate battle - DevoxxUK
 
DBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor PresentationDBX First Quarter 2024 Investor Presentation
DBX First Quarter 2024 Investor Presentation
 

Ultrasonic flowmeter-Drinking water and process water

  • 1. TI00105D/06/EN/13.11 71136725 Technical Information Proline Prosonic Flow 91W Ultrasonic Flow Measuring System Flowrate measurement for standard applications with drinking water and process water Applications The sensors are perfectly suited for the non-contact measurement of pure or slightly contaminated liquids, regardless of the pressure or electrical conductivity. • Suitable for pipe diameters in the range DN 15 to 2000 (½" to 80") • Can be used with all metal and plastic pipes lined or unlined • Ideal solution for applications with water, e.g. drinking water, industrial water, saltwater, deionized water, cooling water and heating water • Perfectly suitable for – subsequent mounting – flow monitoring – improving measuring points Features and benefits The Prosonic Flow ultrasonic clamp-on system allows accurate and cost-effective flow measurement from outside the pipe and without the need to interrupt the process. The flow measurement is bidirectional and causes no pressure loss. • Easy, safe and menu-guided sensor mounting ensures precise measuring results • Long-term system integrity thanks to robust sensor and industrial mounting kit design • Automatic frequency scan for optimized installation and maximum measuring performance • IP 68 for pipes under water • Remote configuration using Endress+Hauser's FieldCare software
  • 2. Proline Prosonic Flow 91W 2 Endress+Hauser Table of contents Function and system design. . . . . . . . . . . . . . . . . . . . . 3 Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Measuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Sensor selection and arrangement . . . . . . . . . . . . . . . . . . . . . . . . . 5 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operable flow range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Low flow cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Measuring unit electrical connection . . . . . . . . . . . . . . . . . . . . . . . 7 Connecting the connecting cable . . . . . . . . . . . . . . . . . . . . . . . . . 8 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable-specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Performance characteristics. . . . . . . . . . . . . . . . . . . . 10 Reference operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Operating conditions: installation . . . . . . . . . . . . . . . 11 Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Connection cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Operating conditions: environment . . . . . . . . . . . . . . 12 Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Shock and vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Operating conditions: process . . . . . . . . . . . . . . . . . . 13 Medium temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Medium pressure range (nominal pressure) . . . . . . . . . . . . . . . . . 13 Pressure loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Energy Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 14 Design, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Human interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Display elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Operating elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Language group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Certificates and approvals . . . . . . . . . . . . . . . . . . . . . 19 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 C-Tick mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Other standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Ordering information. . . . . . . . . . . . . . . . . . . . . . . . . 19 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Communication-specific accessories . . . . . . . . . . . . . . . . . . . . . . 21 Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Registered trademarks. . . . . . . . . . . . . . . . . . . . . . . . 23
  • 3. Proline Prosonic Flow 91W Endress+Hauser 3 Function and system design Measuring principle The measuring system operates on the principle of transit time difference. In this measurement method, acoustic (ultrasonic) signals are transmitted between two sensors. The signals are sent in both directions, i.e. the sensor in question works as both a sound transmitter and a sound receiver. As the propagation velocity of the waves is less when the waves travel against the direction of flow than along the direction of flow, a transit time difference occurs. This transit time difference is directly proportional to the flow velocity. A0013117 Principle of the transit time difference measurement method Q = v · A a Sensor b Sensor Q Volume flow v Flow velocity (v & t ) t Transit time difference (t = ta – tb) A Pipe cross-sectional area The measuring system calculates the volume flow of the fluid from the measured transit time difference and the pipe cross-sectional area. In addition to measuring the transit time difference, the system simultaneously measures the sound velocity of the fluid. This additional measured variable can be used to distinguish different fluids or as a measure of product quality. The measuring device can be configured onsite to suit the specific application using Quick Setup menus. bQ ta a tb
  • 4. Proline Prosonic Flow 91W 4 Endress+Hauser Measuring The measuring system consists of one transmitter and two sensors. Different versions are available depending on the specific requirements. The transmitter is used both to control the sensors and to prepare, process and evaluate the measuring signals, and to convert the signals to a desired output variable. The sensors work as sound transmitters and sound receivers. Depending on the application and version, the sensors can be arranged for measurement via one or two traverses  ä 5. Transmitter Mounting accessories The requisite mounting distances must be determined for the sensors. Information on the fluid, the pipe material used and the exact pipe dimensions is needed to determine these values. The values for the sound velocity of the following fluids, pipe materials and lining materials are stored in the transmitter: Prosonic Flow 91 W Field Housing A0006022 Prosonic Flow W Prosonic Flow W DN 15 to 65 (½" to 2½") A0011484 DN 50 to 4000 (2" to 160") A0013475 Fluid Pipe material Lining • Water • Sea water • Distilled water • Ammonia • Alcohol • Benzene • Bromide • Ethanol • Glycol • Kerosene • Milk • Methanol • Toluene • Lube oil • Fuel Oil • Petrol • Carbon steel • Ductile Iron • Stainless steel • Alloy C • PVC • PE • LDPE • HDPE • PVDF • PA • PP • PTFE • Glass pyrex • Mortar • Rubber • Tar Epoxy Es c
  • 5. Proline Prosonic Flow 91W Endress+Hauser 5 Sensor selection and arrangement The sensors can be arranged in two ways: • Mounting arrangement for measurement via one traverse: the sensors are located on opposite sides of the pipe. • Mounting arrangement for measurement via two traverses: the sensors are located on the same side of the pipe. A0005728 Sensor mounting arrangement (top view) 1 Mounting arrangement for measurement via one traverse 2 Mounting arrangement for measurement via two traverses Recommendations The number of traverses required depends on the sensor type, the nominal diameter and the thickness of the pipe wall. We recommend the following types of mounting: 1 2 Sensor Type Nominal Diameter Sensor Frequency Sensor ID Type of Mounting 1) Prosonic Flow W DN 15 to 65 (½" to 2 ½") 6 MHz W-CL-6F 2 traverses 3) DN 80 (3") 2 MHz W-CL-2F 2 traverses DN 100 to 300 (4" to 12") 2 MHz (or 1 MHz) W-CL-2F W-CL-1F 2 traverses 2) DN 300 to 600 (12" to 24") 1 MHz (or 2 MHz) W-CL-1F W-CL-2F 2 traverses 2) DN 650 to 2000 (26" to 80") 1 MHz (or 0.5 MHz) W-CL-1F W-CL-05F 1 traverse 2) 1) The installation of clamp-on sensors is principally recommended in the 2 traverse type installation. This type of installation allows the easiest and most comfortable type of mounting. However, in certain applications a 1 traverse installation may be preferred: • Certain plastic pipes with wall thickness > 4 mm (0.16 in) • Lined pipes • Applications with fluids with high acoustic damping 2) 0.5 MHz sensors are also recommended for applications with composite material pipes such as GRP and may be recommended for certain lined pipes, pipes with wall thickness >10 mm (0.4 in), or applications with media with high acoustic damping. In addition, for these applications we principally recommend mounting the W sensors in a 1 traverse configuration. 3) 6 MHz sensors are recommended for applications where flow velocity is < 10 m/s (32.8 Hz/s)
  • 6. Proline Prosonic Flow 91W 6 Endress+Hauser Input Measured variable Flow velocity (differential delay proportional to flow velocity) Measuring range Typically v = 0 to 15 m/s (0 to 50 ft/s) at the specified measuring accuracy Operable flow range Over 150 : 1 Output Output signal Current output: • Galvanically isolated • Full scale value adjustable • Temperature coefficient: typ. 2 μA/°C, resolution: 1.5 μA • Active: 4 to 20 mA, RL < 700 (for HART: RL  250 ) Pulse/status output: • Galvanically isolated • Open collector • 30 V DC / 250 mA • Passive • Can be configured as: – Pulse output: pulse value and pulse polarity can be selected, max. pulse width adjustable (5 to 2000 ms), pulse frequency max. 100 Hz – Status output: for example, can be configured for error messages, empty pipe detection, flow recognition, limit value Signal on alarm • Current output  failsafe mode selectable. • Pulse/frequency output  failsafe mode selectable Load See “Output signal” Low flow cutoff Switching point for the low flow freely selectable. Galvanic isolation All circuits for inputs, outputs, and power supply are galvanically isolated from each other.
  • 7. Proline Prosonic Flow 91W Endress+Hauser 7 Power supply Measuring unit electrical connection a0005838 Connecting the transmitter (Aluminium-Fieldhousing). cable cross-section: max. 2.5 mm(AWG 13) a Cover b Cable for power supply: 85 to 260 V AC, 20 to 55 V AC, 16 to 62 V DC c Terminal for power supply: d Terminal for power supply: Nr. 1–2 (terminal assignment) e Signal cable f Ground terminal für signal cable g Terminal connector for signal cable: Nr. 24–27 (terminal assignment) h Service connector i Ground terminal for potential matching Terminal assignment Prosonic Flow 91W e b 2127 – 25 – 26 + 24 + L1 (L+) N (L-) e g b d h cf b a e i Order variant Terminal No. (inputs/outputs) 24 (+)/25 (–) 26 (+)/27 (–) 1 (L1/L+) /2 (N/L–) Fixed communication boards (fixed assignment) 91***-***********A Pulse output HART current output Power supply Functional values see "Output signal" see "supply voltage"
  • 8. Proline Prosonic Flow 91W 8 Endress+Hauser Connecting the connecting cable Connection sensor cable in the electronics compartment A0015907 a, b Sensor connection cable c Cable gland holder d Cable gland Supply voltage Transmitter 85 to 260 V AC, 45 to 65 Hz 20 to 55 V AC, 45 to 65 Hz 16 to 62 V DC Sensor Powered by the transmitter Cable entry Power supply and signal cables (inputs/outputs) • Cable entry M20 × 1.5 (8 to 12 mm; 0.31 to 0.47 in) • Cable gland for cables, 6 to 12 mm ( 0.24" to 0.47") • Thread for cable entries ½" NPT, G ½" Connection cable (sensor /transmitter) Cable glands for one multicore connection cable (1 ×  8 mm) per cable entry • Cable gland M20 × 1.5 • Thread for cable entries ½" NPT, G ½" Connection cable (sensor /transmitter) Cable glands for two single core connection cable (2 ×  4 mm) per cable entry • Cable gland M20 × 1.5 • Thread for cable entries ½" NPT, G ½" The Prosonic Flow W DN 15 to 65 (½ to 2½") is grounded via the cable gland. a0016008 Cable gland for one multicore connection cable (1 ×8 mm /0.31 in) per cable entry a b d c
  • 9. Proline Prosonic Flow 91W Endress+Hauser 9 A0008152 Cable gland for two connection cables (2 × Q 4 mm/0.16") per cable entry Cable-specification Only use the connection cable supplied by Endress+Hauser. Different versions of the connecting cables are available  ä 21. Prosonic Flow • Cable material: – Prosonic Flow 91W (DN 50 to 4000/ 2" to 160") PVC (standard) or optional PTFE – Prosonic Flow 91W (DN 15 to 65 / ½" to 2½") TPE-V • Cable length: – For use in a non hazardous zone: 5 to 60 m (16.4 to 196.8 ft) ! Note! To ensure correct measuring results, route the connection cable well clear of electrical machines and switching elements. power consumption 85 to 250 V AC: <12 VA (incl. measuring sensor) 20 to 28 V AC: <7 VA (incl. measuring sensor) 11 to 40 V DC: <5 W (incl. measuring sensor) Power supply failure Lasting min. 1 power cycle HistoROM/T-DAT save measuring system data if the power supply fails Potential equalization For potential equalization, no special measures are necessary.
  • 10. Proline Prosonic Flow 91W 10 Endress+Hauser Performance characteristics Reference operating conditions • Fluid temperature: +28 °C ± 2 K • Ambient temperature: +22 °C ± 2 K • Warm-up period: 30 minutes Installation: • Sensor and transmitter grounded. • The measuring sensors are mounted correctly. Maximum measured error Measured error The measured error depends on a number of factors. A distinction is made between the measured error of the device (Prosonic Flow 91 = 0.5 % of the measured value) and an additional installation-specific measured error (typically 1.5 % of the measured value) that is independent of the device. The installation-specific measured error depends on the installation conditions on site, such as the nominal diameter, wall thickness, real pipe geometry, fluid etc. The sum of the two measured errors is the measured error at the measuring point. A0011347 Example of the measured error in a pipe with a nominal diameter DN > 200 (8") a Measured error of the device (0.5 % o.r. ± 3 mm/s b Measured error due to installation conditions (typically 1.5 % o.r.) c Measured error at the measuring point: 0.5 % o.r. ± 3 mm/s + 1.5 % o.r. = 2 % o.r. ± 3 mm/s. Measured error at the measuring point The measured error at the measuring point is made up of the measured error of the device (0.5 % o.r.) and the measured error resulting from the installation conditions on site. Given a flow velocity > 0.3 m/s (1 ft/s) and a Reynolds number > 10000, the following are typical error limits: o.r. = of reading Measurement Report If required, the device can be supplied with a measurement report. To certify the performance of the device, a measurement is performed under reference conditions. Here, the sensors are mounted on a pipe with a nominal diameter of DN 100 (4"). The measurement report guarantees the following error limits of the device (at a flow velocity > 0.3 m/s (1 ft/s) and a Reynolds number > 10000): o.r. = of reading Repeatability Max. ± 0.3 % for flow velocity > 0.3 m/s (1 ft/s) 0 0.5 2.0 3.5 % m/s2 4 6 8 10 12 b c a Nominal diameter Device error limits + Installation-specific error limits (typical)  Error limits at the measuring point (typical) DN 15 (½") ±0.5 % o.r. ± 5 mm/s + ±2.5 % o.r.  ±3 % o.r. ± 5 mm/s DN 25 to 200 ±0.5 % o.r. ± 7.5 mm/s + ±1.5 % o.r.  ±2 % o.r. ±7.5 mm/s > DN 200 ±0.5 % o.r. ± 3 mm/s + ±1.5 % o.r.  ±2 % o.r. ± 3 mm/s Nominal diameter Guaranteed error limits of the device Guaranted error limits of the device Prosonic Flow W DN 15 (½"), DN 25 (1"), DN 40 (1½"), DN 50 (2") ±0.5 % o.r. ± 5 mm/s Prosonic Flow W DN 100 (4") ±0.5 % o.r. ± 7.5 mm/s
  • 11. Proline Prosonic Flow 91W Endress+Hauser 11 Operating conditions: installation Installation instructions Mounting location Correct flow measurement is possible only if the pipe is full. It is preferable to install the sensors in a riser. ! Note! Entrained air or gas bubbles in the measuring tube can result in an increase in measuring errors. For this reason, avoid the following mounting locations: • Highest point of a pipeline. Risk of air accumulating. • Directly upstream of a free pipe outlet in a vertical pipe. Risk of partial pipe filling. A0001103 Orientation Vertical Recommended orientation with upward direction of flow (View A). With this orientation, entrained solids will sink and gases will rise away from the sensor when the fluid is stagnant. The piping can be completely drained and protected against solids buildup. Horizontal In the recommended installation range in a horizontal installation position (View B), gas and air collections at the pipe cover and problematic deposits at the bottom of the pipe have a smaller influence on measurement. a0001105 A Vertical B Horizontal C Recommended installation range max. 120° A B C C
  • 12. Proline Prosonic Flow 91W 12 Endress+Hauser Inlet and outlet runs If possible, install the sensor well clear of assemblies such as valves, T-pieces, elbows, etc. If several flow obstructions are installed, the longest inlet or outlet run must be considered. Compliance with the following requirements for the inlet and outlet runs is recommended to ensure measuring accuracy. A0013079 Inlet and outlet runs (top view) 1 Valve (2/3 open) 2 Pump 3 Two pipe bends in different directions Connection cable Route the cable well clear of electrical machines and switching elements Cable specification  ä 8 Operating conditions: environment Ambient temperature range Transmitter –25 to +60 °C (–13 to +140 °F) At ambient temperatures below –20 °C (–4 °F) the readability of the display may be impaired. Install the transmitter at a shady location. Avoid direct sunlight, particularly in warm climatic regions. Sensor Prosonic Flow W –20 to +80 °C (–4 to +176 °F) Optional: 0 to +130 °C (–32 to +265 °F) It is permitted to insulate the sensors mounted on the pipe. Connecting cable (sensor/transmitter) • Standard (TPE-V): –20 to +80 °C (–4 to 175 °F) (multi core, sensor DN 15 to 65 / ½" to 2½")  • Standard (PVC): –20 to +70 °C (–4 to 158 °F) (single core, sensor DN 50…4000 /2" to 160") • Optional (PTFE): –40 to +170 °C (–40 to 338 °F) (single core, sensor DN 50…4000 /2" to 160") • It is permitted to insulate the sensors mounted on the pipes. • Mount the transmitter in a shady location and avoid direct sunlight, particulary in warm climatic regions. ! Note!  Can be used with the version for 0…130 °C /-32…256 °F. Storage temperature The storage temperature corresponds to the operating temperature range of the measuring transmitter and the appropriate measuring sensors and the corresponding sensor cable (see above). 1 2 3 ³ 15 x DN ³ 3 x DN ³ 20 x DN ³ 15 x DN ³ 20 x DN
  • 13. Proline Prosonic Flow 91W Endress+Hauser 13 Degree of protection Transmitter IP 67 (NEMA 4X) Sensors IP 67 (NEMA 4X) Optional: IP 68 (NEMA 6P) Shock and vibration resistance according to IEC 68-2-6 Operating conditions: process Medium temperature range –20 to +80 °C (–4 to +176 °F) Optional: 0 to +130 °C (32 to +265 °F) Medium pressure range (nominal pressure) Perfect measurement requires that the static fluid pressure is higher than vapor pressure, to avoid outgasing. Pressure loss There is no pressure loss. Energy Measurement The Prosonic Flow 91W Ultrasonic is well suited for making or retrofitting energy measurement for hot or chilled water systems - often used in conjunction with Endress+Hauser Flow and Energy Manager RMC621/RMS621. The quantity of heat is calculated from the process variable for flow and the differential from the feed and return temperature. Energy Manager can also determine the quantity of heat in water flow from process variable flow and a single temperature measurement. Installation of delta heat measurement • Temperature measurement takes place via two separate sensors which are directly connected to the Endress+Hauser Energy Manager. (Temperature sensors and Energy Manager supplied separately). • The Prosonic Flow 91W can be installed on either the hot or cold side of the heat exchanger. A0013111 Layout for delta heat measurement of hot or chilled water system Q Esc E- + T1 T2
  • 14. Proline Prosonic Flow 91W 14 Endress+Hauser Mechanical construction Design, dimensions Dimensions field housing A0006063-ae Dimensions pipe mounting a0005819 Esc E- + 190 (7.48) 178 (7.0) ~150 (~5.9) 113 (4.45) == Ø8.6(M8)(0.34) 200(7.87) 150(5.9) Ø 129 (5.1) mm (inch) 100 (3.94) 80 (3.15) 52(2.0) 50(1.97) 190 (7.48) Esc E- + A Esc E- + B 80 (3.15) 172.5(6.79) &185 ( 3.34)& mm (inch)
  • 15. Proline Prosonic Flow 91W Endress+Hauser 15 Prosonic Flow W sensor (DN 15 to 65 / ½" to 2½") A0011502 Mounting arrangement for measurement via one traverse Dimensions in SI units Dimensions in US units B A C EF D A B C D E F 72 331 39 28 233 450 All dimensions in [mm] A B C D E F 2.83 13.03 1.54 1.10 .17 17.72 All dimensions in [inch]
  • 16. Proline Prosonic Flow 91W 16 Endress+Hauser Prosonic Flow W sensor (DN50 to 2000 / 2" to 80") A0011401 Mounting arrangement for measurement via two traverse Dimensions in SI units Dimensions in US units E A DB I C H G F A B C D E F 56 62 145 111  58 Max. 872 G H Depends on the measuring point conditions (pipe, fluid etc.). Dimension "H" can be determined: • by the transmitter prior to the mounting (Quick Setup or FieldCare) • when specifying the flowmeter (online (Applicator) Pipe outer diameter All dimensions in [mm] A B C D E F 2.20 2.44 5.71 4.37  2.28 Max. 34.3 G H Depends on the measuring point conditions (pipe, fluid etc.). Dimension "H" can be determined: • by the transmitter prior to the mounting (Quick Setup or FieldCare) • when specifying the flowmeter (online (Applicator) Pipe outer diameter All dimensions in [inch]
  • 17. Proline Prosonic Flow 91W Endress+Hauser 17 Prosonic Flow W sensor (DN50 to 2000 / 2" to 80") A0011155 Mounting arrangement for measurement via one traverse Dimensions in SI units Dimensions in US units E DH A B G C F A B C D E F 56 62 145 111  58 Max. 872 G H Depends on the measuring point conditions (pipe, fluid etc.). Dimension "H" can be determined: • by the transmitter prior to the mounting (Quick Setup or FieldCare) • when specifying the flowmeter (online (Applicator) Pipe outer diameter All dimensions in [mm] A B C D E F 2.20 2.44 5.71 4.37  2.28 Max. 34.3 G H Depends on the measuring point conditions (pipe, fluid etc.). Dimension "H" can be determined: • by the transmitter prior to the mounting (Quick Setup or FieldCare) • when specifying the flowmeter (online (Applicator) Pipe outer diameter All dimensions in [inch]
  • 18. Proline Prosonic Flow 91W 18 Endress+Hauser Weight • Transmitter housing: 2.4 kg (5.2 lb) • Flowrate measuring sensors W (clamp-on) incl. mounting rail and tensioning bands: 2.8 kg (6.2 lb) Materials Transmitter Wall-mounted housing: powder-coated die-cast aluminum Sensor • Sensor holder: stainless steel 1.4308/CF-8 • Sensor housing: stainless steel 1.4301/304 • Strapping bands/bracket: stainless steel 1.4301/304 • Sensor contact surfaces: chemically stable plastic Connecting cable (sensor/transmitter) • PVC/TPE-V connecting cable – Cable sheath: PVC/TPE-V – Cable connector: nickeled brass 2.0401/C38500 Human interface Display elements • Liquid crystal display: illuminated, two lines each with 16 characters • Custom configuration for presenting different measured values and status variables • 1 totalizer Operating elements Local operation via three operating keys (S, O, F) Remote operation Operation via HART protocol and FieldCare Language group English, German, Spanish, Italian, French
  • 19. Proline Prosonic Flow 91W Endress+Hauser 19 Certificates and approvals CE mark The measuring system is in conformity with the statutory requirements of the EC Directives. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-Tick mark The measuring system is in conformity with the EMC requirements of the Australian Communications and Media Authority (ACMA). Ex approval Information about currently available Ex versions (FM, CSA) can be supplied by your Endress+Hauser Sales Center on request. All explosion protection data are given in a separate documentation which is available upon request. Other standards and guidelines • EN 60529 Degrees of protection provided by enclosures (IP code) • EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use • IEC/EN 61326 "Emission in accordance with Class A requirements". Electromagnetic compatibility (EMC requirements). • ANSI/ISA-S82.01 Safety Standard for Electrical and Electronic Test, Measuring, Controlling and Related Equipment - General Requirements. Pollution Degree 2, Installation Category II. • CAN/CSA-C22.2 No. 1010.1-92 Safety Requirements for Electrical Equipment for Measurement and Control and Laboratory Use. Pollution degree 2 • NAMUR NE 21 Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment. • NAMUR NE 43 Standardization of the signal level for the breakdown information of digital transmitters with analog output signal. • NAMUR NE 53 Software of field devices and signal-processing devices with digital electronics. Ordering information The Endress+Hauser service organization can provide detailed ordering information and information on the order codes on request.
  • 20. Proline Prosonic Flow 91W 20 Endress+Hauser Accessories Various accessories, which can be ordered separately from Endress+Hauser, are available for the transmitter and the sensor. The Endress+Hauser service organization can provide detailed information on the order codes on request. Device-specific accessories Device-specific accessories Accessory Description Order code Sensor W (DN 15 to 65, (½" to 2½") Clamp-on version DN 15 to 65, –20 to +80 °C (½" to 2 ½", –4 to +176 °F), 5.0 MHz • IP 67 / NEMA 4X • IP 68 / NEMA 6P DK9WS - 1* DK9WS - 3* DN 15 to 65, 0 to +130 °C (½" to 2 ½", +32 to +266 °F), 5.0 MHz • IP 67 / NEMA 4X • IP 68 / NEMA 6P DK9WS - 2* DK9WS - 4* Sensor W (DN 50 to 4000, (2" to 157") Clamp-on version DN 50 to 300, –20 to +80 °C (2" to 12", –4 to +176 °F), 2.0 MHz • IP 67 / NEMA 4X • IP 68 / NEMA 6P DK9WS - B* DK9WS - N* DN 100 to 4000, –20 to +80 °C (4" to 160", –4 to +176 °F), 1.0 MHz • IP 67 / NEMA 4X • IP 68 / NEMA 6P DK9WS - A* DK9WS - M* DN 100 to 4000, 0 to +130 °C (4" to 160", +32 to +266 °F), 1.0 MHz • IP 67 / NEMA 4X DK9WS - P* DN 50 to 300, 0 to +130 °C (2" to 12", +32 to +266 °F), 2.0 MHz • IP 67 / NEMA 4X DK9WS - S* DN 100 to 4000, –20 to +80 °C (4" to 160", –4 to +176 °F), 0.5 MHz • IP 67 / NEMA 4X • IP 68 / NEMA 6P DK9WS - R* DK9WS - T* Accessory Description Order code Mounting kit for aluminum field housing Mounting kit for wall-mount housing. DK9WM - C Sensor holder set Prosonic Flow W (DN 15 to 65, ½" to 2½") • Sensor holder, clamp-on version Prosonic Flow W (DN 50 to 4000, 2" to 160") • Sensor holder, fixed retaining nut, clamp-on version • Sensor holder, detachable retaining nut, clamp on version DK9SH - 1 DK9SH - A DK9SH - B Clamp-on installation set Sensor fastening for Prosonic Flow W (DN 15 to 65, ½" to 2 ½") • U-Bolt DN15-32 (½ to 1 ¼") • Strapping bands DN 40 to 65 (1 ½ to 2 ½") (DN 50 to 4000, 2" to 160") • Without sensor fastening • Strapping bands DN 50 to 200 (2" to 8") • Strapping bands DN 200 to 600 (8" to 24") • Strapping bands DN 600 to 2000 (24" to 80") • Strapping bands DN 2000 to 4000 (80" to 160") DK9IC - 11* DK9IC - 21* DK9IC - A* DK9IC - B* DK9IC - C* DK9IC - D* DK9IC - E* • Without mounting tools • Spacing ruler DN 50 to 200 (2" to 8") • Spacing ruler DN 200 to 600 (8" to 24") • Fastener, 1 Traverse DN 50 to 4000 (2" to 160") DK9IC - *1 DK9IC - *2 DK9IC - *3 DK9IC - *6
  • 21. Proline Prosonic Flow 91W Endress+Hauser 21 Communication-specific accessories Conduit adapter for connecting cable Prosonic Flow W (DN 15 to 65, ½" to 2 ½") • Conduit adapter incl. cable entry M20 × 1,5 • Conduit adapter incl. cable entry ½" NPT • Conduit adapter incl. cable entry G ½" Prosonic Flow W (DN 50 to 4000, 2" to 160") • Conduit adapter incl. cable entry M20 × 1,5 • Conduit adapter incl. cable entry ½" NPT • Conduit adapter incl. cable entry G ½" DK9CB - AA1 DK9CB - AA2 DK9CB - AA3 DK9CB - AB1 DK9CB - AB2 DK9CB - AB3 Connecting cable For sensor DN 15 to 65, ½" to 2 ½" 5 m (16 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F) 10 m (33 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F) 15 m (49 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F) 30 m (98 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F) For sensor DN 50 to 4000, 2" to 160" 5 m (16 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F) 10 m (33 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F) 15 m (49 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F) 30 m (98 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F) 60 m (197 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F) DK9SS - AAA DK9SS - AAB DK9SS - AAC DK9SS - AAD DK9SS - ABA DK9SS - ABB DK9SS - ABC DK9SS - ABD DK9SS - ABJ Acoustic coupling fluid • Coupling fluid 0 to 170 °C (+32 to 338 °F), Standard • Adhesive coupling fluid –40 to +80 °C (–40 to 176 °F) • Water-soluble coupling fluid –20 to +80 °C (–4 to 176 °F) • Coupling fluid DDU 19, –20 to +60 °C (–4 to 140 °F) • Coupling fluid –40 to +100 °C (–40 to 212 °F), Standard, type MBG2000 DK9CM - 2 DK9CM - 3 DK9CM - 4 DK9CM - 6 DK9CM - 7 Accessory Description Order code Accessory Description Order code HART Communicator Field Xpert SFX 100 Handheld terminal for remote configuration and for obtaining measured values via the HART current output (4 to 20 mA). Contact your Endress+Hauser representative for more information. SFX100 – ******* Fieldgate FXA320 Gateway for remote interrogation of HART sensors and actuators via Web browser: • 2-channel analog input (4 to 20 mA) • 4 binary inputs with event counter function and frequency measurement • Communication via modem, Ethernet or GSM • Visualization via Internet/Intranet in the Web browser and/or WAP cellular phone • Limit value monitoring with alarm signaling via e-mail or SMS • Synchronized time stamping of all measured values. FXA320 - ***** Fieldgate FXA520 Gateway for remote interrogation of HART sensors and actuators via Web browser: • Web server for remote monitoring of up to 30 measuring points • Intrinsically safe version [EEx ia]IIC for applications in hazardous areas • Communication via modem, Ethernet or GSM • Visualization via Internet/Intranet in the Web browser and/or WAP cellular phone • Limit value monitoring with alarm signaling via e-mail or SMS • Synchronized time stamping of all measured values • Remote diagnosis and remote configuration of connected HART devices FXA520 - **** FXA195 The Commubox FXA195 connects intrinsically safe Smart transmitters with HART protocol to the USB port of a personal computer. This makes the remote operation of the transmitters possible with the aid of configuration programs (e.g. FieldCare). Power is supplied to the Commubox by means of the USB port FXA195 – *
  • 22. Proline Prosonic Flow 91W 22 Endress+Hauser Service-specific accessories Accessory Description Order code Applicator Software for selecting and planning flowmeters. The Applicator can be downloaded from the Internet or ordered on CD-ROM for installation on a local PC. Contact your Endress+Hauser representative for more information. DXA80 - * Fieldcheck Tester/simulator for testing flowmeters in the field. When used in conjunction with the "FieldCare" software package, test results can be imported into a database, printed out and used for official certification. Contact your Endress+Hauser representative for more information. 50098801 FieldCare FieldCare is Endress+Hauser's FDT-based plant asset management tool. It can configure all intelligent field units in your system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition. See the product page on the Endress+Hauser Web site: www.endress.com FXA291 Service interface from the measuring device to the PC for operation via FieldCare. FXA291 – * Memograph M graphic display recorder The Memograph M graphic display recorder provides information on all the relevant process variables. Measured values are recorded correctly, limit values are monitored and measuring points analyzed. The data are stored in the 256 MB internal memory and also on a DSD card or USB stick. Memograph M boasts a modular design, intuitive operation and a comprehensive security concept. The ReadWin® 2000 PC software is part of the standard package and is used for configuring, visualizing and archiving the data captured. The mathematics channels which are optionally available enable continuous monitoring of specific power consumption, boiler efficiency and other parameters which are important for efficient energy management. RSG40-************
  • 23. Proline Prosonic Flow 91W Endress+Hauser 23 Documentation • Flow measurement (FA005D/06) • Operating Instructions for Prosonic Flow 91 (BA100D/06) • Supplementary documentation on Ex-ratings: FM, CSA Registered trademarks HART® Registered trademark of HART Communication Foundation, Austin, USA HistoROM™, T-DAT™, FieldCare® , Field Xpert™, Fieldcheck® Registered or registration-pending trademarks of Endress+Hauser Flowtec AG, Reinach, CH
  • 24. Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI00105D/06/EN/13.11 71136725 FM+SGML6.0 ProMoDo