R
DIXSON
071-40208C
Application
AMETEK Dixson bargraphs are appropriate in any application
where moving pointer meters have been used in the past, and
in applications where greater accuracy, readability, and reliabil-
ity are desirable. Signal sensitivities span ANSI C39.1 ranges, all
conventional current loops, and voltage control signals. An op-
tional RS-422 serial data bus allows for distributed control sys-
tem applications. The instruments are suitable for local or
remote, primary or redundant system indication.
The BB101P enclosure is form-factor compatible with stan-
dard, 6-inch edgewise switchboard instruments and is a direct
replacement for the GE/Yokogawa 180, International Sigma
Model 1151/1251, Westinghouse/Weschler VX252, and the
Modutech and Crompton 6-inch meters. This simplifies retrofit
into existing systems without panel modifications.
For control applications, the optional set point relay module
provides on/off and differential gap control and annunciation
using three set points. The optional digital display reads to 10
percent over- and underrange.
An optional temperature measurement module makes the in-
strument a direct-reading indicator for E, J, K, and T thermo-
couples or 100-ohm RTD, and an optional retransmission
module simplifies distribution of the temperature parameter
throughout the system.
User-programmability provides maximum versatility and mini-
mizes the need for spares. A solid-state design with no moving
parts yields a highly reliable product, especially under condi-
tions of shock, vibration, dust and moisture. Features such as
linearization, sensor power, retransmission, and min/max readings
make the “PRO” Series the ideal choice for your application.
BB101P Programmable Bargraph
(Class III-Commercial/Industrial Grade)
Features
• Brilliant red LED display for excellent visibility
• Minimum 88,000-hour MTBF
• Rugged—high resistance to vibration and shock
• Microprocessor-based design
• Programmable configuration using front panel switches or
PC serial link
• Available with or without program switches on front
• Input signal ranges switch-selectable
• Auto-calibration algorithm
• Linearization of input signals
• Min/max signal memory (peak/valley hold)
• Universal 6-inch rectilinear form interchangeable with all
major manufacturers and panel cutouts
• Front panel mounting
• Underrange/overrange indication
• Modular design for flexibility and options
Options
• Digital display with true minus-sign indication
• Green or amber LEDs
• On/off control using three set point relays
• Direct temperature measurement
• Auxiliary transducer power supply
• Two-wire, isolated retransmission
A
METEK Dixson “PRO” (PROgrammable) Series
bargraphs are the preferred choice for new appli-
cations, or for replacement of switchboard meters,
other common size indicators, and set point controllers.
The “PRO” Series is feature-enhanced, and options are
available to solve most common application problems.
These models are easily configurable for maximum flexi-
bility. Nuclear-qualified versions are also available (see
data sheet P/N 071-40216).
• GE/Yokogawa 180
• Sigma 1151/1251
• Westinghouse/Wechler VX252
• Modutech 6-inch meters
• Crompton 6-inch meters
R
DIXSON
287 27 Road, Grand Junction, CO 81503
Phone: (970) 244-1241 • FAX: (970) 245-6267
Toll-Free:(888) 302-0639
Internet: www.ametek.com/dixson
E-mail: info.dixson@ametek.com
071-40208C
0204
Note: for ISA S67.04 and RP67.04 Part II, consult factory for models and assistance.
PHYSICAL CHARACTERISTICS
Number of bargraph segments 101
Resolution 1.0%
ENCLOSURE MATERIAL Non-glare black Noryl or ABS case
complying with UL94 V-0 or V-1
DIGITAL DISPLAY OPTION (True minus sign) –9999 to 9999
Number of digits 4
Resolution 0.01% ± 1 count*
ENVIRONMENTAL CHARACTERISTICS
Operating temperature range (MIL-E16400G, Class 4) 0 to +60° C
Storage temperature range –40 to +85° C
POWER REQUIREMENTS Either 115/230 VAC at 50, 60, 400 Hz
or 5, 12, 24 or 48 VDC
Line regulation ±10%
Power consumption (typical, depends upon options) 3.5/7.0 VA
SENSITIVITY RANGES (Reference ANSI C39.1 Std. Sensitivities)
STANDARD FULL SCALE INPUTS FROM ZERO
(DIP-switch selectable):
DC currents 500 µA to 50 mA
DC voltages 1 to 250 V
OPTIONAL FULL SCALE INPUTS FROM ZERO
DC currents – factory configured 50 µA to 250 mA
Plug-in modules:
RS-422 Serial Data Comm.
DC voltages 50 mV to <1000 mV
AC currents 1 mA to 1000 mA; 5 A
AC voltages 250 mV to 250 V
Thermocouple - Type E –100 to +1000° C
Thermocouple - Type J –18 to +760° C
Thermocouple - Type K –18 to +1370° C
Thermocouple - Type T –160 to +400° C
RTD (100-ohm platinum) –200 to +850° C
BB101P Specifications
DC INPUT PARAMETERS
Linearity 0.02% of span ± 1 count*
Accuracy 0.04% of span ± 1 count*†
Zero stability <0.01% per °C
Gain stability <0.02% per °C
Input impedance:
For voltage inputs >200 k ohms
For 4 to 20 mADC current inputs 100-ohm compliance resistor
For 10 to 50 mADC current inputs 40-ohm compliance resistor
For all other current inputs Consult factory
Response time (typical) 175 ms
Overload (signal) 200% or 250 VDC maximum
AC INPUT PARAMETERS (true RMS-reading)
Linearity 0.4% of span **
Accuracy 0.5% of span **
Zero stability <0.04% per °C
Gain stability <0.04% per °C
Input impedance for voltage inputs >200 k ohms
Response time (typical) 325 ms
Overload (signal) 200% or 250 VAC maximum
SET POINT OPTION (internal module)
Standard set points LO and HI
Configurable alarm HI/HI (default) or LO/LO
Setability 0.1%
Hysteresis 1.0%
Relay response time (typical):
For DC inputs 350 ms
For AC inputs 650 ms
Relay contact ratings (three Form C): 0.4 A at 125 VAC
2 A at 30 VDC
RETRANSMISSION ACCURACY (4 to 20 mA) ± 0.1%
LINEARIZATION
8th
-order polynomial (nine terms). Refer to “PRO” Series Interface Kit.
* 1 count is defined as a ± unit value change of the right-most digit.
† Call factory for thermocouple, RTD, and square root input accuracy information.
** Except for first 5% of span.
BB101P Dimensions

Mais conteúdo relacionado

Mais procurados

Metal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow MeterMetal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow MeterMiller Energy, Inc.
 
Pump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion SwitchesPump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion SwitchesMiller Energy, Inc.
 
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...ENVIMART
 
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitterLiquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitterENVIMART
 
Turbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from HofferTurbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from HofferFlow-Tech, Inc.
 
GE Advanced Modular Calibrator for Process Measurement Instruments
GE Advanced Modular Calibrator for Process Measurement InstrumentsGE Advanced Modular Calibrator for Process Measurement Instruments
GE Advanced Modular Calibrator for Process Measurement InstrumentsFlow-Tech, Inc.
 
Thermal dispersion switch for flow, level, interface, or temperature
Thermal dispersion switch for flow, level, interface, or temperatureThermal dispersion switch for flow, level, interface, or temperature
Thermal dispersion switch for flow, level, interface, or temperatureFlow-Tech, Inc.
 
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...ENVIMART
 
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodesOrbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodesENVIMART
 
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...ENVIMART
 
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...PT. Siwali Swantika
 
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...ENVIMART
 
Sm electronics services exhbit. ppt
Sm electronics services exhbit. pptSm electronics services exhbit. ppt
Sm electronics services exhbit. pptSachin Shinde
 
Thermal Dispersion Mass Flow Measurement
Thermal Dispersion Mass Flow MeasurementThermal Dispersion Mass Flow Measurement
Thermal Dispersion Mass Flow MeasurementMiller Energy, Inc.
 
Thermal Mass Flow Meter for Oil & Gas Applications
Thermal Mass Flow Meter for Oil & Gas ApplicationsThermal Mass Flow Meter for Oil & Gas Applications
Thermal Mass Flow Meter for Oil & Gas ApplicationsClassic Controls, Inc.
 
Toshniwal - Thermal mass flow meters and controller
Toshniwal - Thermal mass flow meters and controllerToshniwal - Thermal mass flow meters and controller
Toshniwal - Thermal mass flow meters and controllerSangeethaS99
 
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions Monitoring
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions MonitoringThermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions Monitoring
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions MonitoringClassic Controls, Inc.
 
Liquid Level Measurement Using the Bubbler Method
Liquid Level Measurement Using the Bubbler MethodLiquid Level Measurement Using the Bubbler Method
Liquid Level Measurement Using the Bubbler MethodMiller Energy, Inc.
 

Mais procurados (20)

Metal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow MeterMetal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow Meter
 
Pump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion SwitchesPump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion Switches
 
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
 
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitterLiquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
 
Turbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from HofferTurbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from Hoffer
 
GE Advanced Modular Calibrator for Process Measurement Instruments
GE Advanced Modular Calibrator for Process Measurement InstrumentsGE Advanced Modular Calibrator for Process Measurement Instruments
GE Advanced Modular Calibrator for Process Measurement Instruments
 
Thermal dispersion switch for flow, level, interface, or temperature
Thermal dispersion switch for flow, level, interface, or temperatureThermal dispersion switch for flow, level, interface, or temperature
Thermal dispersion switch for flow, level, interface, or temperature
 
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
 
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodesOrbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
 
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...
 
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
 
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
 
Sm electronics services exhbit. ppt
Sm electronics services exhbit. pptSm electronics services exhbit. ppt
Sm electronics services exhbit. ppt
 
Thermal Dispersion Mass Flow Measurement
Thermal Dispersion Mass Flow MeasurementThermal Dispersion Mass Flow Measurement
Thermal Dispersion Mass Flow Measurement
 
Thermal Mass Flow Meter for Oil & Gas Applications
Thermal Mass Flow Meter for Oil & Gas ApplicationsThermal Mass Flow Meter for Oil & Gas Applications
Thermal Mass Flow Meter for Oil & Gas Applications
 
Ins and Outs of I/P Transducers
Ins and Outs of I/P TransducersIns and Outs of I/P Transducers
Ins and Outs of I/P Transducers
 
Toshniwal - Thermal mass flow meters and controller
Toshniwal - Thermal mass flow meters and controllerToshniwal - Thermal mass flow meters and controller
Toshniwal - Thermal mass flow meters and controller
 
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions Monitoring
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions MonitoringThermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions Monitoring
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions Monitoring
 
Siemens Air velocity sensor
Siemens Air velocity sensorSiemens Air velocity sensor
Siemens Air velocity sensor
 
Liquid Level Measurement Using the Bubbler Method
Liquid Level Measurement Using the Bubbler MethodLiquid Level Measurement Using the Bubbler Method
Liquid Level Measurement Using the Bubbler Method
 

Semelhante a Process Digital Bargraph Display for Industrial Control and Automation

ComNet PS48VDC10A Data Sheet
ComNet PS48VDC10A Data SheetComNet PS48VDC10A Data Sheet
ComNet PS48VDC10A Data SheetJMAC Supply
 
Computer conversions hsdc_hrdc_specsheet
Computer conversions hsdc_hrdc_specsheetComputer conversions hsdc_hrdc_specsheet
Computer conversions hsdc_hrdc_specsheetElectromate
 
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...Belilove Company-Engineers
 
Pid controllers
Pid controllersPid controllers
Pid controllersESD India
 
Pid controllers
Pid controllersPid controllers
Pid controllersESD India
 
DSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdfDSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdfIrvingGuatemala
 
Process Control Instruments India - Canopus Instruments
Process Control Instruments India - Canopus InstrumentsProcess Control Instruments India - Canopus Instruments
Process Control Instruments India - Canopus Instrumentssmita_kale
 
Ultrasonic Level Indicators with TC connection
Ultrasonic Level Indicators with TC connectionUltrasonic Level Indicators with TC connection
Ultrasonic Level Indicators with TC connectionNK Instruments Pvt. Ltd.
 
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersMoisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersAlliance Technical Sales, Inc.
 
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-seriesENVIMART
 
DFAE_Energy_Dalian_2011.pptx
DFAE_Energy_Dalian_2011.pptxDFAE_Energy_Dalian_2011.pptx
DFAE_Energy_Dalian_2011.pptxPatilPushkraj
 
Applied motion products stm datasheet
Applied motion products stm datasheetApplied motion products stm datasheet
Applied motion products stm datasheetElectromate
 
Netzer ds 130-specsheet
Netzer ds 130-specsheetNetzer ds 130-specsheet
Netzer ds 130-specsheetElectromate
 
Netzer DS 90 Specsheet
Netzer DS 90 SpecsheetNetzer DS 90 Specsheet
Netzer DS 90 SpecsheetElectromate
 
Netzer DS 37 16 Specsheet
Netzer DS 37 16 SpecsheetNetzer DS 37 16 Specsheet
Netzer DS 37 16 SpecsheetElectromate
 

Semelhante a Process Digital Bargraph Display for Industrial Control and Automation (20)

ComNet PS48VDC10A Data Sheet
ComNet PS48VDC10A Data SheetComNet PS48VDC10A Data Sheet
ComNet PS48VDC10A Data Sheet
 
Computer conversions hsdc_hrdc_specsheet
Computer conversions hsdc_hrdc_specsheetComputer conversions hsdc_hrdc_specsheet
Computer conversions hsdc_hrdc_specsheet
 
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
 
Pid controllers
Pid controllersPid controllers
Pid controllers
 
Pid controllers
Pid controllersPid controllers
Pid controllers
 
DSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdfDSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdf
 
Li m 4_20
Li m 4_20Li m 4_20
Li m 4_20
 
Products
ProductsProducts
Products
 
Process Control Instruments India - Canopus Instruments
Process Control Instruments India - Canopus InstrumentsProcess Control Instruments India - Canopus Instruments
Process Control Instruments India - Canopus Instruments
 
Miniprobe Ultrasonic Level Indicator
Miniprobe Ultrasonic Level IndicatorMiniprobe Ultrasonic Level Indicator
Miniprobe Ultrasonic Level Indicator
 
Ultrasonic Level Indicators with TC connection
Ultrasonic Level Indicators with TC connectionUltrasonic Level Indicators with TC connection
Ultrasonic Level Indicators with TC connection
 
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersMoisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
 
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
 
DFAE_Energy_Dalian_2011.pptx
DFAE_Energy_Dalian_2011.pptxDFAE_Energy_Dalian_2011.pptx
DFAE_Energy_Dalian_2011.pptx
 
Applied motion products stm datasheet
Applied motion products stm datasheetApplied motion products stm datasheet
Applied motion products stm datasheet
 
Lvm 110
Lvm 110Lvm 110
Lvm 110
 
transmitter
transmittertransmitter
transmitter
 
Netzer ds 130-specsheet
Netzer ds 130-specsheetNetzer ds 130-specsheet
Netzer ds 130-specsheet
 
Netzer DS 90 Specsheet
Netzer DS 90 SpecsheetNetzer DS 90 Specsheet
Netzer DS 90 Specsheet
 
Netzer DS 37 16 Specsheet
Netzer DS 37 16 SpecsheetNetzer DS 37 16 Specsheet
Netzer DS 37 16 Specsheet
 

Mais de Classic Controls, Inc.

Magnetic Level Indicators (MLIs) and Bridle Combination Units
Magnetic Level Indicators (MLIs) and Bridle Combination UnitsMagnetic Level Indicators (MLIs) and Bridle Combination Units
Magnetic Level Indicators (MLIs) and Bridle Combination UnitsClassic Controls, Inc.
 
Drying Compressed Air In Hazardous Atmospheres
Drying Compressed Air In Hazardous AtmospheresDrying Compressed Air In Hazardous Atmospheres
Drying Compressed Air In Hazardous AtmospheresClassic Controls, Inc.
 
Signal Fire Wireless Telemetry Catalog
Signal Fire Wireless Telemetry CatalogSignal Fire Wireless Telemetry Catalog
Signal Fire Wireless Telemetry CatalogClassic Controls, Inc.
 
Compressed Coalescing Filters for Industrial Use
Compressed Coalescing Filters for Industrial UseCompressed Coalescing Filters for Industrial Use
Compressed Coalescing Filters for Industrial UseClassic Controls, Inc.
 
Blunt Rod Lightning Protection Comparison
Blunt Rod Lightning Protection ComparisonBlunt Rod Lightning Protection Comparison
Blunt Rod Lightning Protection ComparisonClassic Controls, Inc.
 
Segmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas OperationsSegmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas OperationsClassic Controls, Inc.
 
Nitrogen Generator Systems for Industrial Applications
Nitrogen Generator Systems for Industrial ApplicationsNitrogen Generator Systems for Industrial Applications
Nitrogen Generator Systems for Industrial ApplicationsClassic Controls, Inc.
 
Yokogawa CENTUM VP Process Control and Automation Platform
Yokogawa CENTUM VP Process Control and Automation PlatformYokogawa CENTUM VP Process Control and Automation Platform
Yokogawa CENTUM VP Process Control and Automation PlatformClassic Controls, Inc.
 
Electro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion ControlElectro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion ControlClassic Controls, Inc.
 
Fuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion EfficiencyFuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion EfficiencyClassic Controls, Inc.
 
GE Consolidated Pressure Relief and Safety Valves
GE Consolidated Pressure Relief and Safety ValvesGE Consolidated Pressure Relief and Safety Valves
GE Consolidated Pressure Relief and Safety ValvesClassic Controls, Inc.
 
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...Classic Controls, Inc.
 
Stainless Steel Cast NAMUR Mounting Bracket
Stainless Steel Cast NAMUR Mounting BracketStainless Steel Cast NAMUR Mounting Bracket
Stainless Steel Cast NAMUR Mounting BracketClassic Controls, Inc.
 
Pressure Measurement Handbook for Process Control
Pressure Measurement Handbook for Process ControlPressure Measurement Handbook for Process Control
Pressure Measurement Handbook for Process ControlClassic Controls, Inc.
 
Electro-Hydraulic Linear Actuators for Industrial Valves
Electro-Hydraulic Linear Actuators for Industrial ValvesElectro-Hydraulic Linear Actuators for Industrial Valves
Electro-Hydraulic Linear Actuators for Industrial ValvesClassic Controls, Inc.
 
Energy Calculator for Usage Monitoring
Energy Calculator for Usage MonitoringEnergy Calculator for Usage Monitoring
Energy Calculator for Usage MonitoringClassic Controls, Inc.
 
Pressure Regulating Valve - Type G-4 Cash Valve
Pressure Regulating Valve - Type G-4 Cash ValvePressure Regulating Valve - Type G-4 Cash Valve
Pressure Regulating Valve - Type G-4 Cash ValveClassic Controls, Inc.
 

Mais de Classic Controls, Inc. (20)

Magnetic Level Indicators (MLIs) and Bridle Combination Units
Magnetic Level Indicators (MLIs) and Bridle Combination UnitsMagnetic Level Indicators (MLIs) and Bridle Combination Units
Magnetic Level Indicators (MLIs) and Bridle Combination Units
 
Drying Compressed Air In Hazardous Atmospheres
Drying Compressed Air In Hazardous AtmospheresDrying Compressed Air In Hazardous Atmospheres
Drying Compressed Air In Hazardous Atmospheres
 
Signal Fire Wireless Telemetry Catalog
Signal Fire Wireless Telemetry CatalogSignal Fire Wireless Telemetry Catalog
Signal Fire Wireless Telemetry Catalog
 
Compressed Coalescing Filters for Industrial Use
Compressed Coalescing Filters for Industrial UseCompressed Coalescing Filters for Industrial Use
Compressed Coalescing Filters for Industrial Use
 
Blunt Rod Lightning Protection Comparison
Blunt Rod Lightning Protection ComparisonBlunt Rod Lightning Protection Comparison
Blunt Rod Lightning Protection Comparison
 
Ultrasonic Gas Flow Measurement
Ultrasonic Gas Flow MeasurementUltrasonic Gas Flow Measurement
Ultrasonic Gas Flow Measurement
 
Segmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas OperationsSegmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas Operations
 
Resilient Seated Butterfly Valves
Resilient Seated Butterfly ValvesResilient Seated Butterfly Valves
Resilient Seated Butterfly Valves
 
Nitrogen Generator Systems for Industrial Applications
Nitrogen Generator Systems for Industrial ApplicationsNitrogen Generator Systems for Industrial Applications
Nitrogen Generator Systems for Industrial Applications
 
Yokogawa CENTUM VP Process Control and Automation Platform
Yokogawa CENTUM VP Process Control and Automation PlatformYokogawa CENTUM VP Process Control and Automation Platform
Yokogawa CENTUM VP Process Control and Automation Platform
 
Electro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion ControlElectro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion Control
 
Fuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion EfficiencyFuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion Efficiency
 
PMV Digital Valve Positioner
PMV Digital Valve PositionerPMV Digital Valve Positioner
PMV Digital Valve Positioner
 
GE Consolidated Pressure Relief and Safety Valves
GE Consolidated Pressure Relief and Safety ValvesGE Consolidated Pressure Relief and Safety Valves
GE Consolidated Pressure Relief and Safety Valves
 
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...
 
Stainless Steel Cast NAMUR Mounting Bracket
Stainless Steel Cast NAMUR Mounting BracketStainless Steel Cast NAMUR Mounting Bracket
Stainless Steel Cast NAMUR Mounting Bracket
 
Pressure Measurement Handbook for Process Control
Pressure Measurement Handbook for Process ControlPressure Measurement Handbook for Process Control
Pressure Measurement Handbook for Process Control
 
Electro-Hydraulic Linear Actuators for Industrial Valves
Electro-Hydraulic Linear Actuators for Industrial ValvesElectro-Hydraulic Linear Actuators for Industrial Valves
Electro-Hydraulic Linear Actuators for Industrial Valves
 
Energy Calculator for Usage Monitoring
Energy Calculator for Usage MonitoringEnergy Calculator for Usage Monitoring
Energy Calculator for Usage Monitoring
 
Pressure Regulating Valve - Type G-4 Cash Valve
Pressure Regulating Valve - Type G-4 Cash ValvePressure Regulating Valve - Type G-4 Cash Valve
Pressure Regulating Valve - Type G-4 Cash Valve
 

Último

Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesPrabhanshu Chaturvedi
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfKamal Acharya
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxfenichawla
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGMANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGSIVASHANKAR N
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 

Último (20)

Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGMANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 

Process Digital Bargraph Display for Industrial Control and Automation

  • 1. R DIXSON 071-40208C Application AMETEK Dixson bargraphs are appropriate in any application where moving pointer meters have been used in the past, and in applications where greater accuracy, readability, and reliabil- ity are desirable. Signal sensitivities span ANSI C39.1 ranges, all conventional current loops, and voltage control signals. An op- tional RS-422 serial data bus allows for distributed control sys- tem applications. The instruments are suitable for local or remote, primary or redundant system indication. The BB101P enclosure is form-factor compatible with stan- dard, 6-inch edgewise switchboard instruments and is a direct replacement for the GE/Yokogawa 180, International Sigma Model 1151/1251, Westinghouse/Weschler VX252, and the Modutech and Crompton 6-inch meters. This simplifies retrofit into existing systems without panel modifications. For control applications, the optional set point relay module provides on/off and differential gap control and annunciation using three set points. The optional digital display reads to 10 percent over- and underrange. An optional temperature measurement module makes the in- strument a direct-reading indicator for E, J, K, and T thermo- couples or 100-ohm RTD, and an optional retransmission module simplifies distribution of the temperature parameter throughout the system. User-programmability provides maximum versatility and mini- mizes the need for spares. A solid-state design with no moving parts yields a highly reliable product, especially under condi- tions of shock, vibration, dust and moisture. Features such as linearization, sensor power, retransmission, and min/max readings make the “PRO” Series the ideal choice for your application. BB101P Programmable Bargraph (Class III-Commercial/Industrial Grade) Features • Brilliant red LED display for excellent visibility • Minimum 88,000-hour MTBF • Rugged—high resistance to vibration and shock • Microprocessor-based design • Programmable configuration using front panel switches or PC serial link • Available with or without program switches on front • Input signal ranges switch-selectable • Auto-calibration algorithm • Linearization of input signals • Min/max signal memory (peak/valley hold) • Universal 6-inch rectilinear form interchangeable with all major manufacturers and panel cutouts • Front panel mounting • Underrange/overrange indication • Modular design for flexibility and options Options • Digital display with true minus-sign indication • Green or amber LEDs • On/off control using three set point relays • Direct temperature measurement • Auxiliary transducer power supply • Two-wire, isolated retransmission A METEK Dixson “PRO” (PROgrammable) Series bargraphs are the preferred choice for new appli- cations, or for replacement of switchboard meters, other common size indicators, and set point controllers. The “PRO” Series is feature-enhanced, and options are available to solve most common application problems. These models are easily configurable for maximum flexi- bility. Nuclear-qualified versions are also available (see data sheet P/N 071-40216). • GE/Yokogawa 180 • Sigma 1151/1251 • Westinghouse/Wechler VX252 • Modutech 6-inch meters • Crompton 6-inch meters
  • 2. R DIXSON 287 27 Road, Grand Junction, CO 81503 Phone: (970) 244-1241 • FAX: (970) 245-6267 Toll-Free:(888) 302-0639 Internet: www.ametek.com/dixson E-mail: info.dixson@ametek.com 071-40208C 0204 Note: for ISA S67.04 and RP67.04 Part II, consult factory for models and assistance. PHYSICAL CHARACTERISTICS Number of bargraph segments 101 Resolution 1.0% ENCLOSURE MATERIAL Non-glare black Noryl or ABS case complying with UL94 V-0 or V-1 DIGITAL DISPLAY OPTION (True minus sign) –9999 to 9999 Number of digits 4 Resolution 0.01% ± 1 count* ENVIRONMENTAL CHARACTERISTICS Operating temperature range (MIL-E16400G, Class 4) 0 to +60° C Storage temperature range –40 to +85° C POWER REQUIREMENTS Either 115/230 VAC at 50, 60, 400 Hz or 5, 12, 24 or 48 VDC Line regulation ±10% Power consumption (typical, depends upon options) 3.5/7.0 VA SENSITIVITY RANGES (Reference ANSI C39.1 Std. Sensitivities) STANDARD FULL SCALE INPUTS FROM ZERO (DIP-switch selectable): DC currents 500 µA to 50 mA DC voltages 1 to 250 V OPTIONAL FULL SCALE INPUTS FROM ZERO DC currents – factory configured 50 µA to 250 mA Plug-in modules: RS-422 Serial Data Comm. DC voltages 50 mV to <1000 mV AC currents 1 mA to 1000 mA; 5 A AC voltages 250 mV to 250 V Thermocouple - Type E –100 to +1000° C Thermocouple - Type J –18 to +760° C Thermocouple - Type K –18 to +1370° C Thermocouple - Type T –160 to +400° C RTD (100-ohm platinum) –200 to +850° C BB101P Specifications DC INPUT PARAMETERS Linearity 0.02% of span ± 1 count* Accuracy 0.04% of span ± 1 count*† Zero stability <0.01% per °C Gain stability <0.02% per °C Input impedance: For voltage inputs >200 k ohms For 4 to 20 mADC current inputs 100-ohm compliance resistor For 10 to 50 mADC current inputs 40-ohm compliance resistor For all other current inputs Consult factory Response time (typical) 175 ms Overload (signal) 200% or 250 VDC maximum AC INPUT PARAMETERS (true RMS-reading) Linearity 0.4% of span ** Accuracy 0.5% of span ** Zero stability <0.04% per °C Gain stability <0.04% per °C Input impedance for voltage inputs >200 k ohms Response time (typical) 325 ms Overload (signal) 200% or 250 VAC maximum SET POINT OPTION (internal module) Standard set points LO and HI Configurable alarm HI/HI (default) or LO/LO Setability 0.1% Hysteresis 1.0% Relay response time (typical): For DC inputs 350 ms For AC inputs 650 ms Relay contact ratings (three Form C): 0.4 A at 125 VAC 2 A at 30 VDC RETRANSMISSION ACCURACY (4 to 20 mA) ± 0.1% LINEARIZATION 8th -order polynomial (nine terms). Refer to “PRO” Series Interface Kit. * 1 count is defined as a ± unit value change of the right-most digit. † Call factory for thermocouple, RTD, and square root input accuracy information. ** Except for first 5% of span. BB101P Dimensions