1. Institutional Water Use
Water Use In Schools –
How to Conduct a Water
Audit and Save!
Brent M. White
Suncoast Earth Force
Teachers Workshop
August 2, 2010
Gary Adult High School
Tampa, FL
2. Why Take Action on
Environmental Issues?
Industry, business, and government
organizations are adopting sustainable
practices in their work place.
Incorporating these practices may
provides benefits including:
Reduced utility bills
Improved property value
Greater competitiveness
Enhanced public image
Improved local ecosystem
5/17/2011 2
3. What Can Schools Do?
Schools too have been taking action on
environmental issues.
By taking action, schools will be able to:
Save money!
Instruct current generations on
how to deal with future issues.
Integrate environmental education
into the curriculum.
Reduce waste and other environmental impacts.
Improve cooperation throughout the school community.
Promote environmental values, attitudes,
knowledge and skills to their students and staff.
5/17/2011 3
4. Why Water?
Water is only thought about in times of
drought or flood.
Virtually everything we do or use
involves water.
Even though supply is finite, we tend to
take water for granted.
Simple actions can be adopted to reduce
waste and use water wisely.
5/17/2011 4
5. What is a Water Audit?
Monitoring water use is a good start.
Can be achieved by doing a water audit.
An audit will reveal your current water
use and management system.
Provides background information for
developing actions for reducing water
use.
Will also create a starting point from
which improvements can be measured.
5/17/2011 5
6. Conducting the Water Audit
Five components to an water audit
1. Selecting which facility
to evaluate.
2. Gathering facility
demographics.
3. Conduct the on-site
evaluation.
4. Prepare the evaluation report.
5. Follow-up.
5/17/2011 6
7. Selecting Facilities to Evaluate
Compile annual water use records by
facility type.
Refine the database by water used per
measurement parameter.
Compare the water-use rate to the
benchmark value for the type of facility.
Reorder the list of facilities by potential
water savings into a chart.
5/17/2011 7
9. Gathering Facility Demographics
Information to be gathered about a
facility to be audited includes:
Address Number of employees
Facility contact Percent male/female
Title Full / Part time
Age of facility Meter size and count
Building size Water source(s)
Operating hours/days Billing class / rates
Shifts per day 2-years of water history
5/17/2011 9
10. Conducting On-Site Evaluation
Determine the water use rate for all
equipment and processes.
Consistency is important
Major areas to include are:
Sanitation Heating / Cooling
Kitchen Leak detection
Office Water used in products
Miscellaneous Alternative water use
Irrigation Staff input
5/17/2011 10
11. Evaluation Report Contents
Evaluate Annual Water Consumption
Detail the water and sewer billing data for
the facility by:
Average monthly usage and cost
Peak monthly usage and cost
Average daily usage and cost
Total annual usage and cost
Monthly use by meter type
Display seasonal influences on water use.
5/17/2011 11
12. Seasonal Water Use Breakdown
Sample Seasonal Water Use Trends
Irrigation Domestic
Tower Blowdown Linear (Tower Blowdown)
Linear (Irrigation) Linear (Domestic)
Fall Spring
900
800
700
600
Use (gal)
500
400
300
200
100
0
Apr-04 May-04 Jun-04 Jul-04 Aug-04 Sep-04 Oct-04 Nov-04 Dec-04 Jan-05 Feb-05 Mar-05
Month
5/17/2011 12
13. Evaluation Report Contents
Water Budget Includes:
Facility Statistics
Equipment water use ratings
(Existing and Proposed)
Frequency of use
Days per year of use
Estimated / Adjusted use
Per year
Estimated savings
Per year
5/17/2011 13
14. The Water Budget
Estimated Adjusted Estimated
Water Usage Days Per Use/Yr Use/Yr Savings/Yr
Application Basis Existing Proposed Frequency Year (ccf) (ccf) (ccf)
Heating/Cooling
Cooling Towers 350 Tons 53.76 gal/ton/day 43.01 gal/ton/day 1 uses/day 365 days 9,181.60 7,345.63 1,835.98
9,181.60 7,345.63 1,835.98
Sanitation
Toilets 1,400 Customers 1.6 gpf 1.6 gpf 0.25 flush/person/day 312 days 233.58 233.58 0.00
Toilets 20 Staff 1.6 gpf 1.6 gpf 4 flush/person/day 312 days 53.39 53.39 0.00
Urinals 700 Male customers 1.5 gpf 1 gpf 0.25 flush/person/day 312 days 109.49 72.99 36.50
Urinals 10 Staff 1.5 gpf 1 gpf 2 flush/person/day 312 days 12.51 8.34 4.17
Faucets 1,400 Customers 2.2 gpf 1.5 gpf 0.25 min/day 312 days 321.18 218.98 102.19
Faucets 20 Staff 2.2 gpm 1.5 gpm 1 min/day 312 days 18.35 12.51 5.84
Showerheads 21 Staff 2.5 gpm 2.5 gpm 2 min/day 313 days 43.94 43.94 0.00
Total Sanitary: 748.51 599.81 148.70
Kitchen
Hand sinks 3 Number 6 gpm 2.5 gpm 3 min/day 312 days 22.52 9.39 13.14
Prep sinks 6 Number 6 gpm 4 gpm 5 min/day 312 days 75.08 50.05 25.03
Brewed tea sales 1 Number 360 gal/month 360 gal/month 12 months 1 year 5.78 5.78 0.00
Lemonade sales 1 Number 900 gal/month 900 gal/month 12 months 1 year 14.44 14.44 0.00
Coffee sales 1 Number 300 gal/month 300 gal/month 12 months 1 year 4.81 4.81 0.00
Pre-rinse sprayer 2 Number 8 gpm 1.6 gpm 10 min/day 312 days 66.74 13.35 53.39
Ice-machine 1 Number 0.28 gal / lb ice 0.28 gal / lb ice 600 lbs. Ice 312 days 70.07 70.07 0.00
Steam table 1 Number 2 gpd 2 gpd 312 days 1 year 0.83 0.83 0.00
Bun warmer 1 Number 0.25 gpd 0.25 gpd 312 days 1 year 0.10 0.10 0.00
Steam cabinet 1 Number 3 gpd 3 gpd 312 days 1 year 1.25 1.25 0.00
Soda tower 2 Number 10 fl. oz./soda 10 fl. oz./soda 725 sodas 312 day 47.25 47.25 0.00
Total Kitchen: 308.88 217.33 91.56
Misc.
Hose bibb 1 Number 6 gal/use 6 gal/use 3 uses/day 312 days 7.51 7.51 0
Spray sanitizers 1 Number 3 gpd 3 gpd 1 uses/day 312 days 1.25 1.25 0
Floor cleaning 1 Number 3 gal/use 3 gal/use 18 uses/week 312 days 22.52 22.52 0
Total Misc: 31.28 31.28 0
Irrigation
300 sq. ft. 5 gal/sq. ft. 5 gal/sq. ft. 2 uses / week 52 weeks 208.56 208.56 0
Total Water Use: 10,478.84 8,402.60 2,076.24
5/17/2011 14
15. Evaluation Report Contents
Efficiency recommendations / payback
periods related to annual savings
Payback = $ to implement ÷ Annual Savings
Contractors and vendors can supply costs
Annual savings is based on water and
sewer costs
Increased savings when tiered rate
structures are in place.
Incorporate electric savings with items that
use hot water.
5/17/2011 15
16. Evaluation Report Contents
Recommended Water Efficiency Measures
Each recommendation contains:
Current equipment rating
Suggested change
Number of changes, equipment
Cost – estimated (include sewer and
extensions)
Savings – estimated (include sewer and
extensions)
List reclaimed water if applicable
Annual payback periods
5/17/2011 16
17. Sample Recommendation
Install low-volume pre-rinse sprayer
Your pre-rinse sprayer(s) near your dish station use: 6 gpm.
We recommend replacing them with a model that uses: 1.6 gpm.
Note: The Energy Policy Act of 2005 (EPAct), in effect since Jan 1, 2006
states that all pre-rinse units and replacement spray valves used for ware
washing must have a maximum flow of 1.6 gpm at 60 p.s.i.
Project Cost:
Estimated cost: $ 75 per nozzles.
Total project cost: $ 75
Savings:
Estimated savings: 10.98 Kgal per year.
Cost to heat water: $ 0.50 per Kgal.
Water savings value: $ 57.32 (including sewer)
Payback period:
This recommencation may pay for itself
with water and sewer savings in: 1.31 years.
5/17/2011 17
18. Evaluation Report Contents
Secondary Conservation Items
Unallocated water
Water use that is not identified
Special Comments
Possible leaks / detection
Booster pump effects
Availability of reclaimed water
Additional water savings tips
Contact information
5/17/2011 18
20. Satisfaction and Effectiveness
One-year after the evaluation
Follow up with facility
Determine the implementation rate
Gauge the participant’s satisfaction
Measure long-term implementation
Satisfaction with new equipment
Satisfaction with personnel involved
Perceived change in utility bill
Incorporate information about available
related programs
5/17/2011 20
21. Canterbury School Audit
Audit was performed in October ‘09
251 students
46 full-time staff
5 part-time staff
Multiple events throughout year
Sporting events
Theater productions
Community meetings
Parent Association meetings
Booster Club events
5/17/2011 21
22. Canterbury School Audit
Various stages of construction
All had plumbing code requirements specific
to the year the building was constructed.
Evident in the flow rates of sanitary fixtures
Example: Pre-1994 toilets use 3.5 gallons per
flush (gpf), Post-1994 toilets use 1.6 gpf
Requires allocation of facility population to
specific buildings/fixtures
5/17/2011 22
24. Canterbury School Audit
Benchmarks used in Water budget
Flushes per day – US EPA Water Conservation Plan
Guidelines
Faucet minutes per day – US EPA Water Conservation
Plan Guidelines
Showerhead minutes per day – Determined during
audit interviews with facility staff
Visitor Attendance – Estimated at 20,000 per year
Ice Used – Based upon ice machine production ratings
Soda sales – 1.5 sodas per visitor per year
5/17/2011 24
25. Canterbury School Audit
Gallons / Student / Day
Use as a baseline for comparison
Compared to other High Schools in St.
Petersburg’s service area
Gibbs High – 2,200 students – 9.17
Lakewood High – 1,810 students – 4.11
Canterbury School – 251 students – 34.07
5/17/2011 25
26. Canterbury School Audit
Allocation by Water Use Type
Lab/Class Lab/Class
Misc 6.24%
1% Kitchen
3% Irrigation
Kitchen 2.94%
5% 12%
Misc.
12.40%
Irrigation
3.52%
Sanitary
31%
Athletic
16.75%
Cooling
48% Sanitary
58.16%
1997 SWFWMD Study 2008 Canterbury Audit
5/17/2011 26
27. Canterbury School Audit
Indoor recommendations
3.5 Flushometer toilet retrofits
Estimated savings of 201 Kgal
Savings value of $951.54
Payback period of 1.05 years
Bathroom faucet aerators
Estimated savings of 468 Kgal
Savings value of $2,448.63 (includes heating)
Payback period of 0.02 years
Urinal flush valve retrofits
Estimated savings of 58.7 Kgal
Savings value of $279.60
Payback period of 0.45 years
5/17/2011 27
28. Canterbury School Audit
Indoor recommendations
Low-flow showerheads
Estimated savings of 11.7 Kgal
Savings value of $61.19 (includes heating)
Payback period of 1.31 years
Hand sink aerators
Estimated savings of 5.304 Kgal
Savings value of $27.74 (includes heating)
Payback period of 0.22 years
Hose bibb spray nozzles
Estimated savings of 24.57 Kgal
Savings value of $116.22
Payback period of 0.23years
5/17/2011 28
29. Canterbury School Audit
Indoor recommendations
Kitchen/Prep sink aerators
Estimated savings of 11.7 Kgal
Savings value of $61.19 (includes heating)
Payback period of 1.31 years
Summary of Indoor Measures
Recommended Initial Savings Expense Payback
Measures Cost CGal/year Avoided Period (yrs)
Replace 3.5 gpf flushometer toilets $ 1,000.00 2,011.72 $ 951.54 1.05
Install urinal flush valve retrofit kit 125.00 587.40 279.60 0.45
Install faucet aerators in the bathrooms 48.00 4,681.26 2,448.30 0.02
Install low-flow showerheads 80.00 117.00 61.19 1.31
Install hand sink aerators 6.00 53.04 27.74 0.22
Install prep sink aerators 6.00 182.00 95.19 0.06
Use spray nozzles on hose bibbs 27.00 245.70 116.22 0.23
Total: $ 1,292.00 7,878.12 $ 3,979.78 0.48
5/17/2011 29
30. Canterbury School Audit
Outdoor Recommendations
Clean and replace clogged nozzles
Repair leaks in irrigation system
Convert to low-volume irrigation
Application specific recommendations
Straighten nozzles
Cap off some rotors and/or pop-ups
Increase plant bed size
Convert turf areas to mulched areas
Improve uniformity by matching nozzle flow rates to
demands (separate turf from shrub zones)
Realign nozzles so as not to spray on impervious surfaces
5/17/2011 30
31. Canterbury School Audit
Outdoor Recommendations
Irrigation duration/schedule
Time April - October November - March Type
Parking Lot South 20 Twice/Week Once/Week Mixed
Parking Lot North 20 Twice/Week Once/Week Mixed
Elevated Beds 25 Once/Week Once/2 Weeks Plants
East Side of Building 45 Twice/Week Once/Week Turf
Colonade 25 Once/Week Once/2 Weeks Plants
Field House 20 Twice/Week Once/Week Turf
South and Front 25 Once/Week Once/2 Weeks Plants
Inspect system monthly
Visually examine all sprinkler heads
Ten minutes of operating time is allowed
An attendant must be present
Check rain sensor operation
5/17/2011 31
32. Canterbury School Audit
Outdoor Recommendations
Seashore Paspalum (Paspalum vaginatum)
Similar to Bermuda grass
Heals faster
Salt-tolerant
Requires 50% less water
Uses 75% less Nitrogen
Half of all athletic fields in Charlotte
County uses Seashore Paspalum
Varieties: Sea Dwarf, Aloha,
Sea Isle, Sea Spray
5/17/2011 32
33. Canterbury School Audit
Outdoor recommendations
Fountain wind speed control system
Automatically slow down or shut off a
fountain if surrounding wind speeds
are high enough to blow the spray
out of the fountain basin.
Reduces spray drift that reaches
impervious surfaces.
Fountains currently restricted to
4-hours of operation per day.
5/17/2011 33
34. Canterbury School Audit
Outdoor recommendations
Stormwater reuse
Collecting and storing
precipitation for future use.
Done on a larger scale by utilities
Aquifer Storage and Recovery (ASR).
Stores water during the rainy season
for the dry season
Cisterns
Rain Barrels
5/17/2011 34
35. Implementation Options
Alternative funding opportunities:
Performance Contracting
Existing utility rebate programs
Retrofit giveaways
Mini-grants for educational efforts
that incorporate water savings.
Splash mini-grants – School based
Community Education grant
– Public based
Source Water Protection (TBW)
Estuary Program Grants
5/17/2011 35
36. Thank You!
For more info:
Brent.White@swfwmd.state.fl.us
1-800-423-1476 ext. 4214