SlideShare uma empresa Scribd logo
1 de 137
Baixar para ler offline
SCANNER GUIDE

Version 6.20
© 2012 by Anite Finland Ltd. All rights reserved.
This manual, as well as the software described in it, is furnished under license and may only be used
or copied in accordance with the terms of such license. The information in this manual is intended for
informational use only and is subject to change without notice. Anite Finland Ltd assumes no
responsibility or liability for any errors or inaccuracies that may appear in this user manual.
Except as permitted by such license, no part of this publication may be reproduced or transmitted in
any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written
permission of Anite Finland Ltd.
Windows®, Windows® XP, Windows® Vista, Windows® 7, Outlook®, and Internet Explorer are
registered trademarks of the Microsoft® Corporation in the United States and other countries.
MapInfo® and MapX® are registered trademarks of MapInfo® Corporation. CDMA 2000® is a
registered trademark of the Telecommunications Industry Association (TIA -USA). The license
management portion of this Licensed Technology is based on SentinelLM* © 1989-2003 Rainbow
Technologies, Inc. All rights reserved.

Revision 6.20.01, Last edited February 2012
Nem o Sc an n er G u i de

NEMO FSR1
CONNECTING NEMO FSR1 SCANNER
Changing the Nemo FSR1 IP Address
Connecting a GPS Antenna to Nemo FSR1

3

5
5
8
13

CONNECTING NEMO FSR1 SCANNER TO NEMO INVEX CHASSIS
STARTING NEMO FSR1 SCANNER

16

NEMO FSR1 FIRMWARE UPDATE

17

MEASURING WITH NEMO FSR1 SCANNER
Frequency Scanning
TOP-N Pilot Scanning - UMTS
TOP-N Pilot Scanning - CDMA/EVDO
TOP-N Pilot Scanning – LTE
Spectrum Analyzer Measurements
Band Scan

18
18
20
23
24
27
30

CALIBRATING NEMO FSR1

14

32

ANRITSU

33

CONNECTING ANRITSU SCANNERS
33
Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer
Scanner
37
STARTING ANRITSU SCANNERS

41

MEASURING WITH ANRITSU SCANNERS
Frequency Scanning
TOP-N Pilot Scanning - UMTS
Pilot Scrambling Code Scanning
DVB-H Scanning
Spectrum Analyzer Measurements

42
42
45
51
53
54

DRT

57

CONNECTING THE DRT WIMAX 4301A+ SCANNER

57

STARTING DRT SCANNERS

60

MEASURING WITH DRT SCANNERS
Frequency Scanning
Pilot Scanning

62
62
64

PCTEL

67

CONNECTING PCTEL LX CDMA/EVDO/GSM/WCDMA SCANNER
CONNECTING PCTEL EX SCANNERS

67

69

CONNECTING THE PCTEL LX GSM/WCDMA DUAL-MODE SCANNER
CONNECTING THE PCTEL MX SCANNER

76

CONNECTING PCTEL PCT SCANNERS

73

79

CONNECTING PCTEL SCANNERS TO NEMO INVEX CHASSIS
STARTING PCTEL SCANNERS

83

MEASURING WITH PCTEL SCANNERS

89

82
Nem o Sc an n er G u i de

4

Frequency Scanning – PCTEL GSM/UMTS Scanners
Frequency Scanning – PCTEL EX LTE Scanner
Frequency Scanning – PCT GSM Scanner
Frequency Scanning – PCTEL CDMA/EVDO Scanners
TOP-N Pilot Scanning - UMTS
TOP-N Pilot Scanning – CDMA/EVDO
Spectrum Scanning
LTE OFDM Scanning
Pilot Scrambling Code Scanning

ROHDE & SCHWARZ

89
91
93
95
97
99
101
105
108

110

CONNECTING THE ROHDE & SCHWARZ TSMQ/TSML SCANNER

110

CONNECTING THE ROHDE & SCHWARZ TSMW SCANNER113
System Priority Order with R&S TSMW Scanners
115
CONNECTING ROHDE & SCHWARZ SCANNERS TO NEMO INVEX CHASSIS
Connecting R&S TSMW to Nemo Invex with an Ethernet Cable
118
Connecting R&S TSMW to Nemo Invex with a Network Switch
119
STARTING ROHDE & SCHWARZ SCANNERS

123

MEASURING WITH ROHDE & SCHWARZ SCANNERS
Frequency Scanning
TOP-N Pilot Scanning - UMTS
TOP-N Pilot Scanning - CDMA/EVDO
TOP-N Pilot Scanning - LTE
Spectrum Scanning

125
125
127
129
131
134

TROUBLESHOOTING SCANNERS
NEMO FSR1

137
137

117
Nem o F S R1

5

NEMO FSR1
CONNECTING NEMO FSR1 SCANNER
Nemo FSR1 scanner is powered by 10 to 16 VDC. AC operation for the standalone receiver is
achieved by using the optional AC power supply. The AC power supply is designed to work with
100 - 240VAC 50/60Hz. For other voltages or line frequencies contact Anite for the correct
supply.

The standard AC supply is rated at 130 Watts. Actual power requirements will vary depending
number of downconverters installed and the receiver tasking. The maximum power requirement
of the scanner is 50 Watts.
DC operation for the standalone receiver can be achieved by connection to a vehicle 12-volt
system. The following table is provided to budget the system current requirements for various
configurations.
Platform configuration/Module

12 VDC current requirement

Basic system w/ single downconverter

3.0 A

Two downconverter system

3.6 A

The estimates given for the scanner assume maximum utilization of the processing capabilities.

∇

Connecting the Nemo FSR1:
1. Connect an antenna cable to scanner RF input. If you are measuring with two
downconverters, connect an antenna in both RF inputs (see picture below).
Nem o F S R1

2. Connect Ethernet cable(s) to the scanner Ethernet port(s) and to the Nemo Outdoor laptop.
3. Go to Control Panel | Network and Internet | Network and Sharing Center. Click on
Change adapter settings.

4. Right-click on Local Area Connection and select Properties. In the Local Area Connection
Properties dialog, select Internet Protocol Version 4 (TCP/IPv4) and click Properties.

6
Nem o F S R1

7

5. Select Use the following IP address and type in an IP address that is different from that of
the scanner. The IP address should be 192.168.3.xxx where the xxx can be anything else
except 250, 251, 252, or 253 because those four IP addresses are reserved for the scanner.
Click OK and Close.

♦

Please note that by default the Nemo FSR1 is delivered with a fixed IP address. The IP
address can be changed with a separate utility software. The following IP addresses are
used in Nemo Outdoor:
•

"Nemo Scanner LAN" = 192.168.3.253

•

"Nemo Scanner LAN 2" = 192.168.3.252

•

"Nemo Scanner LAN 3" = 192.168.3.251

•

"Nemo Scanner LAN 4" = 192.168.3.250
Nem o F S R1

8

6. Connect the power cable to the scanner and to a power source. Switch power on.
Fuse

Power connector

Fans

Power switch

7. The default address and name settings of the scanner are generally suitable for most users.
There is no need to configure these settings when using the Nemo FSR1 scanner with Nemo
Outdoor.
8. The status LEDs at the front panel display how the scanner is functioning.
LED Name
RxA
RxB
Status
Active
All LEDs

LED Color
Green
Amber
Green
Amber
Green
Amber
Green
Red
Amber

Description
Receiver A enabled
Receiver A disabled i.e. EEPROM not readable
Receiver B enabled
Receiver B disabled i.e. EEPROM not readable
GPS Locked
GPS Unlocked
Ethernet link connected
Ethernet link disconnected
If all four LEDs are amber, the bootloader is
running and the module needs to be reloaded

Changing the Nemo FSR1 IP Address
The default address and name settings of the Nemo FSR1 are generally suitable for most
users. However, if you have two or more Nemo FSR1 scanners connected to the same
measurement laptop, you will need to assign a different IP address for each scanner. By
default, the Nemo FSR1 scanners are delivered with a fixed IP address: 192.168.3.253. When
changing the IP address, please use the following IP addresses supported in Nemo Outdoor:
•

"Nemo Scanner LAN" = 192.168.3.253

•

"Nemo Scanner LAN 2" = 192.168.3.252

•

"Nemo Scanner LAN 3" = 192.168.3.251

•

"Nemo Scanner LAN 4" = 192.168.3.250
Nem o F S R1

Connect a PC to the Nemo FSR1 serial port using the serial adapter cable (available from
Anite). The scanner serial port is located in the lower-right corner of the front panel. Switch on
the scanner.

Figure 1. Nemo FSR1 serial adapter cable
♦

If a serial port is not available on the computer, a USB-to-serial adapter can be used.
Follow the manufacturer’s instructions for driver installation and use of the adapter. If an
adapter is used, the COM port to choose for the Hyperterminal connection should be the
port assigned by Windows to the USB/serial adapter (see Device Manager, Ports).
Start a terminal port software, such as, HyperTerminal. Select COM1 or the port assigned to the
USB/serial adapter in the Connect using field and click Configure.

9
Nem o F S R1

In the COM1 Properties dialog, define the following settings:
Bits per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: Xon/Xoff

Click OK and OK. An empty HyperTerminal window is opened.

10
Nem o F S R1

Press Enter on your keyboard. The following information is displayed.

To change the IP address, press 2 and Enter. Enter the new IP address in format
xxx.xxx.xxx.xxx. For example, 192.168.003.252. Press Enter.

11
Nem o F S R1

The IP address is changed and the window displays the new flash data with the new IP
address. To update the scanner firmware and finalize the changes, press 0 and Enter.

Confirm the firmware update by pressing Y and Enter.
♦

This is an important step to complete the firmware update. If you exit HyperTerminal
without entering 0 and selecting Y when prompted, the firmware will not be updated.

12
Nem o F S R1

13

The scanner firmware is updated and the scanner is restarted. Check from the scanner
information that the IP address has changed. Now you can close the HyperTerminal.

Connecting a GPS Antenna to Nemo FSR1
For optimum performance of the FSR1, it is strongly recommended to connect the GPS antenna
to the scanner. The scanner takes advantage of GPS for timing information which improves the
performance of the signal processing algorithms.
Also note for CDMA/EVDO the scanner must have GPS coverage. If CDMA/EVDO in-building
testing is to be conducted, the scanner should operate at least 30 minutes in GPS coverage
before the antenna is disconnected and then every hour or two of walk testing have an
additional 20 minutes in GPS coverage.
The following GPS antenna is delivered with the Nemo FSR1:
•

Mighty Mouse III
•

28dB gain low noise amplifier

•

Maximum of 6mA current consumption (all voltages)

•

2.5V to 5.5V DC

•

Connector: SMA male

Connect the GPS antenna cable to the GPS connector in the scanner front panel.
Nem o F S R1

14

CONNECTING NEMO FSR1 SCANNER TO NEMO
INVEX CHASSIS
Nemo FSR1 is connected to the Nemo Invex chassis (SI module) with an Ethernet cable.
Ethernet ports are located on the front panel of the Nemo FSR1 scanner and on the front panel
of the Nemo Invex SI module.

Nemo FSR1 front panel.

Nemo Invex SI module front panel.
Nem o F S R1

Nemo FSR1 power cable can be connected to the Nemo Invex chassis. The scanner power
connector is located at the rear of the chassis.

The Nemo FSR1 scanner can be attached on top of the Nemo Invex chassis with a mounting
plate.

15
Nem o F S R1

16

Clearance for air ventilation around the Nemo FSR1 is as follows:
•

10 cm

•

Left side

3 cm

•
♦

Back

Right side

3 cm (not applicable for Rev B scanner)

Note that the air intake is on the left side and exhaust on the back.

STARTING NEMO FSR1 SCANNER
1. Start Nemo Outdoor. Do not load any previous device configuration if asked.
2. From the Measurement menu, select Add New Device.
3. Click on Scanner.
4. From the list select Nemo FSR1 and click Next.
Nem o F S R1

5. In the Scanner Properties dialog, select Nemo Scanner LAN as the Port and click OK.

6. If the dialog did not close, the startup did not succeed. Check the cable connections and the
settings and try again.
7. If the Device Status window is not visible, open it from the View menu. A green light should
be blinking. This means that the device is working properly and scanning using the default
settings. If the status field displays, Device is not started, check that you are in online mode
(click the Work Offline/Online button
). If the device is started but not scanning, check
that you have selected channels to be scanned.

NEMO FSR1 FIRMWARE UPDATE
Nemo FSR1 firmware can be updated using the Nemo FSR1 Firmware Update Utility or through
Nemo Outdoor. For detailed information on using the update utility, please refer to the Nemo
FSR1 Firmware Update Utility Instructions document.
The scanner firmware can also be updated through Nemo Outdoor. Connect the scanner to
Nemo Outdoor and then click the Measurement settings button in the Devices view. Select
Update Firmware.

17
Nem o F S R1

In the File field, browse the latest firmware update file (.ffw) and click Update. The update may
take a few minutes. Do not switch off the scanner!

When the update is complete, close the dialog and restart the scanner.

MEASURING WITH NEMO FSR1 SCANNER
Frequency Scanning
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog you can select the channels to be scanned.

18
Nem o F S R1

19

3. On the Frequency scanning, GSM page, click the Select Channels button to select the
GSM channels to be scanned.

Channel style defines the style of the measured channel. For GSM the option is 200 kHz.
Data mode defines the type of measurement data computed from each sample. Note that the
available selection depends on the scanner type.
•

RX Level Average: the data reported is the average RX level, in dB, of the number of
samples.

Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
Sample size defines the number of samples taken from each channel before a measurement
result is written to file.
Selecting the BSIC decoding option enables BSIC values and co-channel C/I measurements.
BSIC threshold defines the minimum BSIC level that the scanner reports.
Select the BCCH C/I option to activate BCCH decoding. Co-channel C/I is also enabled.
Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID
information can be decoded from BCCH messages. Note that this is only enabled in online
mode and if the option has been purchased with the scanner.
Nem o F S R1

20

When the System information decoding option is selected, L3 messages are written in the log
file.
4. Click the Start Recording button

to start recording the results in an output file.

TOP-N Pilot Scanning - UMTS
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N pilot mode/scanning.

∇

To set pilot scanning settings:
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are
below the threshold, the pilots are not reported.
Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow
Band (200kHz) and Wide Band (3.84MHz).
Correlator parameter is no longer utilized by the FSR1 UMTS scanning algorithms. It is
encouraged to set this parameter to the highest correlation value, 4096.
Nem o F S R1

21

Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
Pilot measurement mode defines the measurement mode for pilot scanning.
•

In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,
weak pilots may be undetected.

•

In High dynamic range mode scanning speed is lower but sensitivity is higher.

Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode. The maximum number is 32.
Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID
information can be decoded from BCCH messages. Note that this is only enabled in online
mode and if the option has been purchased with the scanner.
Delay spread defines if the selected scanner will also measure the delay spread value (in
chips) for each scanned scrambling code. Delay spread is determined as the difference
between the last and first component to break the threshold set in PN Threshold.
P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling
code.
S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling
code.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning.
Nem o F S R1

∇

22

To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N
Configuration button. The Select Channels dialog is opened.

2. The table displays the channel numbers, not the frequencies.
3. You can remove channels from the Selected list by selecting a channel and clicking the
Remove button.
4. You can add channels to the Selected list by selecting a channel from the Available list
and clicking the Add button.
5. Click OK to return to the Measurement Properties dialog.
6. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
7. A green light on the scanner Device Status window should start blinking. This means that
the device is working properly and scanning using the default settings. In TOP-N Mode this
may take a few seconds.
8. Click the Start Recording button

to start recording the results in an output file.
Nem o F S R1

TOP-N Pilot Scanning - CDMA/EVDO
♦

Note that the EVDO measurements can only be performed in a proper way when a
CDMA2000 channel is measured as well. In this way, the time relationship between the
different PN offsets is resolved.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning, CDMA page.

Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow
Band (200kHz) and Wide Band (3.84MHz).
Correlator affects how the scanner works. Bigger correlator size enables the scanner to detect
and measure pilot channels with better dynamic but makes scanning speed slower. For
example, when using correlator size 2048 versus 512, the dynamic range for pilot measurement
changes from –21db to –17db.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the
threshold, the pilots are not scanned.

23
Nem o F S R1

24

Top-N mode option enables/disables TOP-N scrambling code scanning. Number of pilots field
defines how many pilots are reported by the scanner in TOP-N mode.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning.
♦

Note that the Nemo FSR1 scanner supports a max of 90 cell IDs.
3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
5. Click the Start Recording button

to start recording the results in an output file.

TOP-N Pilot Scanning – LTE
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. Go to the Pilot scanning, LTE page to define LTE-specific pilot scanning settings.
Nem o F S R1

Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow
Band (200kHz) and Wide Band (3.84MHz).
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
CINR refers to the Carrier to Interference and Noise ratio value, in dB *100 (e.g., -16.34). It is
based on the requested reuse factor.
Time offset refers to the number of samples between P-SCH Primary Synchronization Signal
arrival time with respect to receiver frequency reference that is derived from GPS reference
time.
Sync signal refers to the ratio between the synchronization channel, i.e., primary and
secondary signal received power and the interference and noise from the same synchronization
signal set.
Reference signal refers to the ratio between the reference signal received power (RSRP) and
the interference and noise from the same reference signal set.
When the System information decoding option is selected, L3 messages are written in the log
file.
The Select Channels button will open the Select Channels dialog where you can select
channels for pilot scanning.
When you select LTE channels, you can also define some channel-specific settings. In the LTE
Channel Specific Settings dialog, select the channel from the Selected channels list and
define the settings.
♦

Note that the available options are device specific.

25
Nem o F S R1

26

Cyclic prefix defines the type of signal the scanner is set to measure. With Autodetect
selected, the scanner will automatically detect the appropriate signal type. If Cyclic Prefix is
known to be Normal (most common), setting the scanner to Normal will increase scanning
speed slightly.
Uplink-downlink configuration refers to LTE TDD frame structure.
Frame structure type 2 is applicable to TDD. Each radio frame of length Tf = 307200 ⋅ Ts = 10 ms
consists of two half-frames of length 153600 ⋅Ts = 5 ms each. Each half-frame consists of five
subframes of length 30720 ⋅Ts = 1 ms . The supported uplink-downlink configurations are listed in
the table below where, for each subframe in a radio frame, “D” denotes the subframe is
reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink
transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One radio frame, Tf = 307200Ts = 10 ms
One half-frame, 153600Ts = 5 ms

One slot,
Tslot=15360Ts

30720Ts

Subframe #0

Subframe #2

One
subframe,
30720Ts
DwPTS

GP

Subframe #3

Subframe #5

Subframe #4

UpPT
S

Subframe #7

DwPTS

GP

Subframe #8

Subframe #9

UpPT
S

Frame structure type 2 (for 5 ms switch-point periodicity):
Uplink-downlink
configuration
0
1
2
3
4
5
6

Downlink-to-Uplink
Switch-point periodicity
5 ms
5 ms
5 ms
10 ms
10 ms
10 ms
5 ms

0
D
D
D
D
D
D
D

1
S
S
S
S
S
S
S

2
U
U
U
U
U
U
U

Subframe number
3 4 5 6 7
U U D S U
U D D S U
D D D S U
U U D D D
U D D D D
D D D D D
U U D S U

8
U
U
D
D
D
D
U

9
U
D
D
D
D
D
D

3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
5. Click the Start Recording button

to start recording the results in an output file.
Nem o F S R1

Spectrum Analyzer Measurements
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Spectrum scanning page. Select the
Enable spectrum scanning option and click on Add.

3. Define the start and stop frequencies within which the measurement will be performed. If
you manually define the start and stop frequencies, you can either select to add the
frequencies to the scanning list or save them as a predefined set. Select your option in the
Add to scanning list menu.
4. Select Set center frequency and bandwidth to define the center frequency and the
bandwidth to be measured. If you manually define the center frequency and bandwidth, you
can either select to add them to the scanning list, or save them as a predefined set. Select
your option in the Add to scanning list menu.

27
Nem o F S R1

♦

If the requested frequency range is not supported by the device, Nemo Outdoor
automatically adjusts the frequency range for the device, and only frequency ranges
supported by the scanning receiver are used to perform spectrum analyzer
measurements.

♦

Based on the start and stop frequency and the number of samples (points), Nemo
Outdoor calculates the correct resolution bandwidth (RBW). It should be noted that
resolution bandwidths with Nemo FSR1 scanners are fixed. The currently supported
values are: 1875, 3750, 7500, 15000, 30000, 60000 and 120000 Hz. Nemo Outdoor
automatically selects the closest RBW to be used.

28
Nem o F S R1

29

5. You can add scanning sets in the Predefined scanning sets field through the Add to
Scanning List button. Click the arrow in the button and select Save as Predefined Set.
Define a name in the Enter Frequency Set Name field and click OK.

6. The name appears in the Predefined scanning sets field along with the chosen frequency
and/or bandwidth information selected in the Reporting field.
7. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
8. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
9. Click the Start Recording button

to start recording the results in an output file.
Nem o F S R1

Band Scan
With the Nemo FSR1 scanner you can perform band scanning. All specified channels are
scanned for the selected band and technology and the strongest measured identifiers (CDMA
PN, EVDO PN, WCDMA SC, LTE Cell ID) for every valid channel of that technology type are
reported. Signal strength and signal quality are reported for each identified channel. This feature
is useful in areas where broadcasted technologies and bands are unknown.
1. To start a band scan, right click the Nemo FSR1 item in the Devices view and select Band
Scan.

2. Available technologies and bands supported by the scanner are shown under Scan
settings. Please note that only licensed technologies (systems) are shown.
3. Select the technologies and bands that you want to be scanned and define the threshold
levels for the parameters available.
4. Finally press the Start Scan button. With the default threshold values it takes approximately
two minutes and 30 seconds to scan GSM 900, 1800 and WCDMA 2100 bands. The
scanning rate can be increased by adjusting the threshold values.

30
Nem o F S R1

5. Scanning results are displayed on the Scan results page. It is possible to save the results
to a text file (.csv).

31
Nem o F S R1

32

CALIBRATING NEMO FSR1
Self-test runs every time the handler is started and notifications are sent to the user interface
depending on the calibration results. Self-test results can be viewed in the Nemo Outdoor
Output window.
•

Test passed
•

•

Calibration warning
•

•

No action required. Indicates that there are no known issues with receiver/down
converter module calibration.

Measured noise level indicates that the down converter is functioning but may
be at or approaching calibration limits. Recommended that the down converter is
calibrated as soon as possible. Please contact Nemo helpdesk or local sales
representative to arrange re-calibration.

Test failure
•

Measured noise levels are significantly out of range and down converter is not
functioning correctly. Recommended that the down converter be returned
immediately for factory assessment, potential repair, and calibration. Please
contact Nemo helpdesk or local sales representative to arrange service for the
unit.
A nr its u

33

ANRITSU
CONNECTING ANRITSU SCANNERS
♦

These instructions apply to all Anritsu scanners, except Anritsu MS2721B DVB-H
Analyzer.
1. Connect the antenna cable to scanner RF Input. If you are measuring with a dual-mode
scanner that supports both GSM and WCDMA, use the RF1 input (see picture). RF2 input
only supports WCDMA scanning.

2. Connect the battery cable to the battery and to a power source.

3. The Battery led of the scanner should turn green.
A nr its u

♦

34

The following steps apply to Anritsu ML8720B and ML8720C scanners. If you are
measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see step 12.
4. Connect the null modem cable to the scanner COM port that can be found below the power
switch.

5. Connect the null modem to one of the PC COM ports
6. Turn the power on in the scanner. The Power led should light up.
7. The scanner should now start, wait until the scanner has started
8. Press the Menu button in the scanner.
9. Use the arrow keys and the Sel button to select Interface and Behavior.
10. Check that the settings are as follows. If not, change them using the arrow keys and the Sel
button (note that the selected item will be underlined as soon as you use the arrow buttons
to switch to another line). To exit the dialog without saving, press the F4 button (Cancel). To
exit the dialog and save the modified settings, press the F5 button (OK).
•

COM1 Protocol: Direct

•

COM1 Baud Rate: 38400 or 57600 or 115200

•

COM1 Stop Bit(s): 1

•

COM1 Data Length: 8

•

COM1 Parity: None

♦

The baud rate 115200 is the fastest option.

♦

Note! Memorize the baud rate. It is needed when starting the device.
A nr its u

35

11. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see the
following steps.
12. Insert the Anritsu installation CD in your PC.
13. Connect the USB cable to the scanner USB port found in the front panel and to the PC.
14. Switch the scanner on.
15. The New Hardware Wizard will start automatically. Select the No, not this time option and
click Next.

16. Select the Install the software automatically option and click Next.
A nr its u

36

17. If a warning message appears, click Continue Anyway. The installation will start. Please
wait while the New Hardware Wizard installs the software. When the installation is complete,
click Finish.

18. To check that the installation was successful, go to Device Manager (Start | Settings |
Control Panel | System | Hardware | Device Manager). Expand the Universal Serial Bus
controllers item. Area Scanner should be on the list.
A nr its u

37

19. Double-click on Area Scanner. Check that the Device Status field displays This device is
working properly. Exit the dialog by clicking OK.

Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu
MS2721B Spectrum Analyzer Scanner
1. To install the device drivers the user must have administrative rights to its PC, and the Take
ownership of files or other objects policy has to be enabled for this user on this PC.
2. Copy the executable file visa400full.exe to your local drive before installing the driver, and
run the installation from the hard drive.
3. Double-click on the file and unzip the contents to your hard-drive. This may take a couple of
minutes.
4. The installation starts automatically.
5. Click Next>> on the welcome page.
A nr its u

38

6. Select the destination folder for the driver and click Next>>.

7. Click Next>> in the Features dialog.

8. Select I accept the License Agreement(s) in the following page and click Next>>.
9. Click Next>> in the following dialog and wait for the installation to finish, and Finish in the
Installation Complete dialog. Note that you may need to restart your computer for the
installation to take effect.
A nr its u

39

10. Connect the scanner with your PC through a network cable. Insert one end of the network
cable in the network cable connector in the scanner, and the other end to the network cable
connector in your PC.

11. Next, you need to make some changes to your PC’s network card properties. Go to Start |
Control Panel | Network Connections, and right-click on Local Area Connection, and
select Properties. In the Local Area Connection Properties dialog, select Internet Protocol
(TCP/IP) and click on Properties. Select Use the following IP address. You need to type in
an IP address out of the range 192.168.0.11 - 192.168.0.14, as those addresses are
reserved for the scanner. Type in, for example, 192.168.0.10. Next, type 255.255.0.0 in the
Subnet mask field. Click OK and Close to exit the dialogs.

12. Next, start the scanner by pressing on the green On/Off button.
13. Press on Shift and then System (8) button on the scanner.
14. On the menu to the right of the screen, select System Options | Ethernet Config by using
the grey buttons next to the screen.
A nr its u

40

15. Select the Set the IP Address Manually using the following Settings by pressing the topmost grey button immediately under the Esc button.
16. Type in the same IP address for both IP and Gateway from those reserved for the scanner
(192.168.0.11 - 192.168.0.14). Here the selected IP address will be 192.168.0.14. You can
move to different directions on the screen through the grey buttons. If the Subnet field is not
automatically filled when filling the IP and Gateway fields, you can use, for example,
255.255.255.255 for it. Press Enter and restart the device by clicking twice on the On/Off
button.
17. When the scanner has restarted, start Nemo Outdoor. Go to Measurement | Add device |
Scanner, and select Anritsu MS2721B DVB-H or Anritsu MS2721B Spectrum Analyzer.
Click Next.
18. In the Scanner Properties dialog that appears, select one of Anritsu LAN 1-4 ports
depending on which IP address you entered on the device. If you entered 192.168.0.11,
select Anritsu LAN 1, if you selected 192.168.0.12, select Anritsu LAN 2, etc. Since
192.168.0.14 was selected earlier, the Anritsu LAN 4 port will be used here.

♦

Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so
they can be left as they are.
19. Click OK. See page 53 for more information on how to perform DVB-H measurements. See
page 53 for instructions regarding settings for the Spectrum Analyzer.
A nr its u

41

STARTING ANRITSU SCANNERS
1. Start Nemo Outdoor. Do not load any previous device configuration if asked.
2. From the Measurement menu, select Add New Device.
3. Click on Scanner.
4. From the list select:
•

For Anritsu ML8720B: Anritsu ML8720B UMTS 2100 and click Next.

•

For Anritsu ML8720C without the GSM option: Anritsu ML8720C UMTS 2100 and click
Next.

•

For Anritsu ML8720C with the GSM option: Anritsu ML8720C GSM/UMTS and click
Next.

•

For Anritsu ML8740A and Anritsu ML8740B without the GSM option: Anritsu ML8740A/
ML8740B UMTS 2100 and click Next.

•

For Anritsu ML8740A and Anritsu ML8740B with the GSM option: Anritsu
ML8740A/ML8740B GSM/UMTS and click Next.

•

For Anritsu MS2721B DVB-H Analyzer: Anritsu MS2721B DVB-H, and click Next.

•

For Anritsu MS2721B Spectrum Analyzer: Anritsu MS2721B Spectrum Analyzer, and
click Next.

5. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to
(ML8720B/ML8720C)/select the USB port (e.g., Anritsu USB1)/or select the Anritsu LAN 1-4
with Anritsu MS2721B DVB-H depending on which IP address was selected for the scanner.
♦

The next step is not valid for the Anritsu ML8740A, Anritsu ML8740B, Anritsu MS2721B
DVB-H, or Anritsu MS2721B Spectrum Analyzer scanner.
A nr its u

42

6. Set the baud rate to the one used by the scanner and click OK. Note that the baud rate
must be the same that you chose when you were connecting the scanner. The dialog
will be closed and the scanner should now be connected to the system.
7. If the dialog did not close, the startup did not succeed. Check the cable connections and the
settings and try again.
8. If the Device Status window is not visible, open it from the View menu. A green light should
be blinking. This means that the device is working properly and scanning using the default
settings. If the status field displays, Device is not started, check that you are in online mode
(click the Work Offline/Online button
).

MEASURING WITH ANRITSU SCANNERS
Frequency Scanning
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog you can select the channels to be scanned:
•

If the scanner supports only one carrier, you can select either GSM or UMTS channels to
be scanned.

•

If the scanner supports two carriers, you can select for scanning both GSM and UMTS
channels. If you select GSM channels, you can select a maximum of one UMTS
channel. If you do not select GSM channels, you can select one or two UMTS channels.

3. On the Frequency scanning, GSM page, click the Select Channels button to select the
GSM channels to be scanned.
A nr its u

♦

43

Note that the scanner reports the 32 strongest channels from the selected GSM channels.

Channel style defines the style of the measured channel. For GSM the options are 200 kHz
and 30 kHz narrow.
Data mode defines the type of measurement data computed from each sample. Note that the
available selection depends on the scanner type.
•

RX Level Average: the data reported is the average RX level, in dB, of the number of
samples.

•

RX Level Maximum: the data reported is the maximum RX level, in dB, of the number of
samples.

•

RX Level Minimum: the data reported is the minimum RX level, in dB, of the number of
samples.

•

RX Level Standard Deviation: the data reported is the standard of deviation of the
number of samples reported as an integer.

•

RX Level 10%: the data reported is the 10th percentile RX level, in dB, of the number of
samples.

•

RX Level 50%: the data reported is the 50th percentile RX level, in dB, of the number of
samples.
A nr its u

44

•

RX Level 90%: the data reported is the 90th percentile RX level, in dB, of the Number of
samples.

Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
Sample size defines the number of samples taken from each channel before a measurement
result is written to file.
Selecting the BSIC decoding option displays BSIC value in a measurement window.
BSIC Threshold defines the minimum BSIC level that the scanner reports.
BCCH C/I option is available with PCTEL and Rohde&Schwarz GSM scanners only.
4. Click the Start Recording button

to start recording the results in an output file.
A nr its u

45

TOP-N Pilot Scanning - UMTS
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode/Scanning.

∇

To set pilot scanning settings:
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.

♦

Note that some of the options are enabled/disabled in this dialog according to the
selected scanner model.
Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow
Band (200kHz) and Wide Band (3.84MHz). For Anritsu scanners, only Wide Band is available.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
A nr its u

46

Number of fingers defines the maximum number of fingers used for RAKE in measurement.
Selective level determines a valid path. Set a value (in dB) to decide a valid path from the
noise floor (average value).
Rake threshold determines a valid path (in dB). Subtracting the set value from a path with a
maximum correlation value gives the lower limit of the valid path.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode.
Delay profile option enables/disables delay profile scanning. The Channel number field
provides a list of channels that can be selected for scanning.
Finger option enables and disables Finger measurements for the scanner.
P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling
code.
SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for
each scrambling code.
S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling
code.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning. If you press the arrow, a drop-down menu will appear from where
you can select Top-N Search Configuration.

♦

Please note that the Top-N Search Configuration dialog is available for Anritsu UMTS
scanners only.
A nr its u

47

In the Top-N Search Configuration dialog you can limit the search performed by the scanner
and consequently speed up the search.

Group specifies the group number for the primary scrambling code in the range of 0 to 63.
Cell specifies the cell number for the primary scrambling code in the range of 0 to 7.
Secondary code specifies the secondary scrambling code. Limit range should be set from 0 to
0.
Channelization code specifies the channelization code. Limit range should be set from 0 to 0.
Search method defines how the search is performed. P-CPICH (primary common pilot
channel) searches with P-CPICH. SCH performs a three-step search with P-SCH and S-SCH.

∇

To select pilot parameters:
1. Select the TOP-N Mode option.
2. Set the Number of Scrambling codes value. This defines how many strongest pilots are to
be reported by the scanner. The maximum is 32 pilots.
A nr its u

∇

48

To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N
Configuration button. The Select Channels dialog is opened.

2. The table displays the channel numbers, not the frequencies.
♦

With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you
are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be
selected.
3. You can remove channels from the Selected list by selecting a channel and clicking the
Remove button.
4. You can add channels to the Selected list by selecting a channel from the Available list
and clicking the Add button.
5. Click OK to return to the Measurement Properties dialog.
A nr its u

∇

49

To select search parameters:
1. Open the Measurement Properties, Pilot scanning, UMTS page. Press down the Top-N
Configuration button and select Top-N Search Configuration.

2. The Top-N Search Configuration dialog opens.
A nr its u

50

3. Set the Group search range. The group number is the scrambling code divided by 8. For
example, SC (scrambling code) 12 = group 1, cell 4.
4. Set the Cell search range. The cell number is the division modulus. For example, SC
(scrambling code) 12 = group 1, cell 4.
5. The Secondary Code and the Channelization Code ranges should be set from 0 to 0 for
scanning only the P-CPICH.
6. Select the Search Method. SCH means that the P-CPICH are searched using P-SCH and
S-SCH. P-CPICH means that the P-CPICH are searched without using P-SCH and S-SCH.
♦

Note that the P-CPICH method is much slower than the SCH method.
7. Click OK to accept the settings and to return to the Measurement Properties dialog.
8. Data processing method defines how the scanner will process samples before reporting.
9. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data
processing method is used.

♦

In pilot scanning mode, the RSSI is always measured for each channel.

♦

In pilot scanning mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
10. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
11. A green light on the scanner Device Status window should start blinking. This means that
the device is working properly and scanning using the default settings. In TOP-N Mode this
may take a few seconds.
12. Click the Start Recording button

to start recording the results in an output file.
A nr its u

51

Pilot Scrambling Code Scanning
Pilot Scrambling Code Scanning or Known Scrambling Code Scanning can be used to scan
known pilots. The Known Scrambling Code Scanning will from now on be referred to as Normal
Pilot Mode.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
1. Go to the Measurement Properties, Pilot scanning, UMTS page .

2. Clear the TOP-N mode option and click the Select Channels button. The Select
Scrambling Codes dialog is opened.
3. Select channels in the Selected channel numbers table by clicking the Select button.
♦

With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you
are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be
selected.
4. For each selected channel, select scrambling codes. Select a channel and click the Select
button below the Selected scrambling codes table.
5. Click OK to return to the Measurement Properties dialog.
A nr its u

52

6. When using an Anritsu scanner in Pilot Scanning mode, you can define the measurement
period. It defines the time period from which results are gathered and processed before
reporting.
7. Data processing method defines how the scanner will process samples before reporting.
♦

In Pilot Scanning Mode the RSSI is always measured for each channel.

♦

In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
8. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
9. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
10. Click the Start Recording button

to start recording the results in an output file.
A nr its u

53

DVB-H Scanning
DVB-H scanning can be performed with the Anritsu MS2721B DVB-H Analyzer scanner.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
11. In the Measurement Properties, Pilot scanning, DVB-H page, select a frequency to be
measured. Anritsu MS2721B DVB-H Analyzer scans frequencies between (DVB-H) 474 850 MHz.

12. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
13. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
14. Click the Start Recording button

to start recording the results in an output file.
A nr its u

54

Spectrum Analyzer Measurements
Spectrum scanning can be performed with the Anritsu MS2721B Spectrum Analyzer scanner.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Spectrum scanning page.
A nr its u

55

3. Select the Enable spectrum scanning option and click on Add.

4. Define the start and stop frequencies within which the measurement will be performed. If
you manually define the start and stop frequencies, you can either select to add the
frequencies to the scanning list or save them as a predefined set. Select your option in the
Add to scanning list menu.
5. Select Set center frequency and bandwidth to define the center frequency and the
bandwidth to be measured. If you manually define the center frequency and bandwidth, you
can either select to add them to the scanning list, or save them as a predefined set. Select
your option in the Add to scanning list menu.
♦

With Anritsu MS2721B spectrum analyzer the supported frequency range is from 9 kHz to
7.1GHz. The sample count is fixed to 551, and RBW is adjusted automatically. RBW is
between 1 Hz - 3 MHz. It is automatically adjusted to the closest value of 1 Hz, 3 Hz, 10 Hz,
30Hz, 100 Hz ... 300 kHz, 1 MHz, 3 MHz.
15. When signal volume is lower than -50dBm, selecting the Use preamplifier functionality in
the Measurement Properties dialog can increase the scanner’s measuring sensitivity,
hence slightly decreasing background noise. However, it is recommended that it is not
selected when signal volume is higher than -50dBm.
A nr its u

56

16. You can add scanning sets in the Predefined scanning sets field through the Add to
Scanning List button. Click the arrow in the button and select Save as Predefined Set.
Define a name in the Enter Frequency Set Name field and click OK.

17. The name appears in the Predefined scanning sets field along with the chosen frequency
and/or bandwidth information selected in the Reporting field.
18. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
19. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
20. Click the Start Recording button

to start recording the results in an output file.
DRT

57

DRT
CONNECTING THE DRT WIMAX 4301A+
SCANNER
♦

Note! The DRT 4301A+ scanner does NOT have an On/OFF switch. The unit is powered by
connecting the power cable and powered off by disconnecting the power cable. When
connecting cables to the unit, the power cable should be the last one connected and the
first one disconnected.
1. Insert one end of the RJ-45 cable in the DATA jack in the scanner, and connect the other
end with the PC.
2. Insert the power cable in the connector marked DC IN.
3. Plug the antenna cable in the FR IN B port in your DRT scanner.

♦

Note that you can only select one of the antennas, 2300/2500MHz or the 3500MHz
antenna, and connect it with the scanner. You must select between the antennas at this
point.

4. Connect the scanner’s GPS antenna cable to the scanner’s GPS port, and place the GPS
antenna on a visible spot.
5. Go to Start | Control Panel | Network Connections on your PC.
6. Right-click on Local Area Connection and select Properties.
7. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) |
Properties.
DRT

58

8. In the General tab, select Use the following IP address, and type 192.168.5.1 in the IP
address field, and 255.255.255.0 in the Subnet mask field.

9. Click OK and Close to exit the dialogs.
10. Now connect the scanner’s power cable. The scanner is now on. A green light will turn on in
the scanner.

11. Start Nemo Outdoor. Go to Measurement | Add New Device | Scanner. Select DRT
WIMAX 2300, DRT WIMAX 2500 or DRT WIMAX 3500 depending on which band you
choose to measure at the time.
DRT

59

12. In the Scanner Properties dialog, select DRT LAN in the Port drop-down menu.

♦

Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so
they can be left as they are.
13. Click OK to exit the dialog.
14. Go to page 62 for more information on conducting WIMAX measurements with the DRT
scanner.
DRT

60

STARTING DRT SCANNERS
1. Start Nemo Outdoor. Do not load any previous device configuration if asked.
2. From the Measurement menu, select Add New Device.
3. Click on Scanner.
4. From the list select:
•

DRT WIMAX 2300, if you want to make measurements with the 2300 MHz (WiMAX) band.

•

DRT WIMAX 2500, if you want to make measurements with the 2500MHz (WiMAX) band.

•

DRT WIMAX 3500, if you want to make measurements with the 3500MHz (WiMAX) band.
DRT

61

5. In the Scanner Properties dialog, set the COM Port to DRT LAN.

♦

Note that the no changes need to be made to the Baud rate, Antenna gain, and Cable loss
fields. See the next chapter for further instructions on how to make measurements.
DRT

62

MEASURING WITH DRT SCANNERS
Frequency Scanning
Frequency scanning can be used to scan band power. It is also useful for checking that the
band is deselected and for finding out the center frequency.
1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. You can enable or disable the integrated GPS receiver through the Advanced button. It is
also possible to use an external GPS device with the scanner.
3. In the Measurement Properties dialog, go to the Frequency scanning page.

4. In the Channel Style list box, select the channel width. The options are Wide Band (5000
kHz) and Wide Band 2 (10000 kHz).
DRT

63

5. Click the Select Frequencies button to open the Select Frequencies dialog.

6. The table displays the available frequencies. Select and add them in the Selected view by
clicking on Add>>.
7. Remove frequencies from the Selected list by selecting a frequency and clicking the
Remove button.
8. Add frequencies in the Selected list by selecting a frequency from the Available list and
clicking the Add button.
9. Click OK to return to the Measurement Properties dialog.
10. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
11. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
12. Click the Start Recording button

to start recording the results in an output file.
DRT

64

Pilot Scanning
1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.

Channel style refers to the style of the channel.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated.
Top-N option enables/disables TOP-N scrambling code scanning. If enabled, scanner will report
results from N best preambles. Number of preambles field defines how many preambles are
reported by the scanner in TOP-N mode.
CINR refers to the Carrier to Interference and Noise ratio value, in dB *100 (e.g., -16.34). It is
based on the requested reuse factor.
Preamble delay refers to the number of samples between expected arrival time and actual
arrival time of preamble with respect to GPS time reference. The values range from 0 to
1023+32. Each sample corresponds to 89.285 nanoseconds.
DRT

65

Reuse factor refers to a system design parameter that can be manipulated to achieve the
desired balance between the interference and the network coverage. The WiMAX air interface
modulating waveform has been divided into three segments (Segment 0, 1 and 2). The
allocation of frequency sub-carrier into these three segments is done in such a way that e.g. a
downlink signal on segment 0 will not interfere with the downlink signal on segment 1. In a
Reuse Factor 1 measurement, contributions from all the three segments are considered in the
measured parameters, so that the CINRs are calculated from all the three segments. When
Reuse Factor 3 is selected, only the contribution of the desired segment is considered, and the
CINRs are calculated only from the same segment. As a broad guideline, measurements
performed with Reuse Factor 1 will provide the signal quality of the all the detected preambles
relative to each other, whereas the Reuse Factor 3 category of measurements will provide the
signal quality of preambles within the same segment.
Delay spread defines if the selected scanner will also measure the delay spread value (in
chips) for each scanned scrambling code. Delay spread is determined as the difference
between the last and first component to break the threshold set in PN Threshold.
3. The Top-N Configuration button will open the Select Frequencies dialog where you can
select frequencies for scanning. The maximum number of frequencies that can be selected
is device specific.
DRT

66

4. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
5. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
6. Click the Start Recording button

to start recording the results in an output file.
PCT EL

67

PCTEL
CONNECTING PCTEL LX
CDMA/EVDO/GSM/WCDMA SCANNER
1. Connect the antenna cable to the scanner RF Input.

2. Connect the scanner GPS antenna cable to the scanner GPS input (above RF Input).
PCT EL

68

3. Connect the scanner power cable to the scanner serial port (Data).

4. The scanner cable is split into a serial cable connector and a power cable connector.
Connect the serial cable to one of the COM ports in the PC. Connect the scanner power
cable to a cigarette lighter in the car.
5. When connecting the scanner power cable, check the Power led:
•
•

∇
♦

If the led blinks orange and black for a while and then turns green, the scanner is
working properly and using baud rate of 115200

•
♦

If the led is first orange for a while and then turns green, the scanner is working properly
and using a baud rate of 38400

If the led is red, the scanner is not working properly. Switch the power off and on again.
If this occurs after usage, the device may be overheated. Let it cool down for a while.

Note! Memorize the baud rate. It is needed when starting the device.

Connecting an external GPS to PCTEL LX EVDO/GSM/WCDMA scanner
Note that you cannot use both the integrated and an external GPS receiver at the same
time.
1. Connect the GPS serial cable to a PC serial port.

♦

If there is only one port in the PC by default, this port should be reserved for the scanner.
In this case connect the GPS to the PCMCIA serial port adapter.
2. Connect the GPS power cable to a cigarette lighter.
PCT EL

69

CONNECTING PCTEL EX SCANNERS
1. To install the device drivers the user must have administrative rights to its PC, and the Take
ownership of files or other objects policy has to be enabled for this user on this PC.
2. Copy the folder /SeeGull EX VCP driver_v.2.0.0.46B to your local drive before installing the
driver, and run the installation from the hard drive.
•

Right click on the folder and select Properties.

•

Clear the Read-only attributes and click OK.

•

Select Apply changes to this folder, subfolder and files as below
and click OK.

3. Double-click on the SeeGull EX VCP Device Driver.msi installer file to start the driver
installation.
4. Click Next in the SeeGull Welcome window that appears.
5. Select the destination folder for the driver in the Destination Folder window, and Click Next,
and click Install.
6. Click Finish in the InstallationShield Wizard Completed window to exit the wizard.
PCT EL

70

7. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front
panel.

8. Connect the power cable to the Power connector in the front panel. Connect the other end of
the cable to a cigarette lighter socket. The SYS indicator in the front panel will light up.
PCT EL

71

9. Connect the antenna cables. It does not matter which antenna cable goes to which RF
connector.

10. Connect the GPS antenna to the connector marked GPS.
PCT EL

72

11. Connect the USB data cable to the USB port in the front panel. Connect the other end of the
USB data cable to your PC.

12. Windows will automatically detect the device.
PCT EL

73

CONNECTING THE PCTEL LX GSM/WCDMA
DUAL-MODE SCANNER
1. Remove the yellow plastic caps from the antenna and GPS connectors in the front panel.

2. Connect the power cable to the Power and Data connector in the front panel. Connect the
other end to a USB port on your computer and to a power source. The green Power indicator
in the scanner front panel will light up.
PCT EL

74

3. Connect the antenna cables. Note that the antenna cables and the connectors in the
scanner front panel are color coded. The OP042 cable marked with yellow is connected to
the RF1 connector marked with yellow (connector on the left). The OP039 cable marked with
blue is connected to the RF2 connector marked with purple (connector in the middle).

4. Connect the GPS antenna to the connector marked GPS (connector on the right).

5. Windows will have detected the new device and will install the required drivers. Insert the
PCTEL installation CD.
6. Select No, not this time in the Welcome dialog.
PCT EL

75

7. Select Install from a list of specific location and click Next.

8. Select Include this option in the search and browse to folder D:EdgeportUSBEdgeport
Vendor Datadriver vx.x. Click Next to start the installation.

9. When the installation is finished, click Finish. Windows will automatically install some
additional drivers and report when the device is ready to be used.
PCT EL

76

CONNECTING THE PCTEL MX SCANNER
1. To install the device drivers the user must have administrative rights to its PC, and the Take
ownership of files or other objects policy has to be enabled for this user on this PC.
2. Browse to folder seegull mx driverMX winusb driver. For 32-bit operating system run
DPInst.exe from “install x86” folder and for 64-bit operating system run DPInst.exe from
“install x64” folder.
3. The PCTEL USB Device Installer window will appear. Click Next.
4. If a Windows Security message appears, click Install.
5. Click Finish in the installation completed window.
6. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front
panel.

7. Connect the power cable to the PWR connector in the front panel. Connect the other end of
the cable to a cigarette lighter socket. Turn the switch to On position. The Status indicator in
the front panel will light up.
PCT EL

77

8. Connect the antenna cables. The label on the scanner lists the frequencies of the radio
modules connected to each specific port, labeled RF1 to RF4. The antenna ports that require
antenna connections are identified by their “frequency” on the label. Since each SeeGull MX
is configured to minimize the number of ports necessary for use, some ports may be inactive
for a particular configuration and are indicated by a blank box.

9. Connect the GPS antenna to the connector marked GPS.
10. Connect the USB data cable to the USB port in the front panel. Connect the other end of the
USB data cable to your PC.
PCT EL

78

11. Windows Vista and Windows 7 will automatically detect and install the device.
12. With Windows XP a Found new Hardware window will appear. Select No, not this time in
the Welcome window. Select Install the software automatically (Recommended) and click
Next. Finally click Finish.
13. Go to Device Manager and select PCTEL Devices. Memorize the port number for the
PCTEL MX Scanner item, as you will need it later on.
PCT EL

79

CONNECTING PCTEL PCT SCANNERS
1. Run the PL2303_Prolific_DriverInstaller_vx.x.exe (x refers to the version number) file on the
installation CD to install device drivers.
2. Click Next in the Welcome window that appears.
3. Click Finish to finish the driver installation.
4. Next, remove the yellow plastic caps from the antenna and GPS connectors in the front
panel of the PCTEL PCT scanner.

5. Connect the antenna cable in the RF Input connector.
PCT EL

80

6. Connect the data cable to the Data connector. Connect the other end of the USB data cable
to your PC.

7. Connect the power cable to the Power connector in the front panel. Connect the other end of
the cable to a cigarette lighter socket.

8. Windows automatically detects the new hardware.
PCT EL

81

9. Go to Start | Control Panel | System | Hardware | Device Manager and select Ports.
Memorize the port number for the Prolific USB-to-Serial Comm Port item, as you will need
it later on.
PCT EL

82

CONNECTING PCTEL SCANNERS TO NEMO
INVEX CHASSIS
PCTEL scanners are connected to the Nemo Invex chassis (UIC module) with a USB cable. If
your PCTEL scanner has a serial cable, you will need a USB serial adapter. The USB cable is
connected to the USB-1 or USB-2 port on the UIC module.

PCTEL scanners can be attached on top of the Nemo Invex chassis with a mounting plate.
PCT EL

83

STARTING PCTEL SCANNERS
∇

Starting the GPS:
With the PCTEL LX WCDMA scanner you can use either the GSP receiver integrated into the
scanner or an external GPS. See page 86 for instructions on how to enable the integrated GPS
receiver.

♦

Note that you cannot use both the integrated and an external GPS receiver at the same
time.

♦

Note that with the PCTEL LX GSM/WCDMA scanner the Internal GPS receiver should be
activated only in UMTS mode.

♦

To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix
at least 30 seconds before starting the Nemo Outdoor application in online mode. If the
existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the
configuration file in offline mode. If scanner does not send any results after 30 seconds,
it is advised to send a reset command to the scanner via the user interface.
1. From the Measurement menu, select Add New Device.
2. Click on GPS.
3. From the list, select the GPS model that you have connected to the PC and click Next.
4. The GPS Properties dialog is opened. Set the parameters (see the GPS User Manual for
instructions). They should be correct by default. Click OK. The view will return to the Nemo
Outdoor main window.
5. In the Device Status window a green light should be blinking. This means that the GPS is
working properly.

∇

Starting the PCTEL MX/LX/EX/PCT GSM/WCDMA/1xEVDO/LTE Scanner:
1. Start Nemo Outdoor. Do not load any previous device configuration if asked.
2. From the Measurement menu, select Add New Device.
3. Click on Scanner.
4. From the list of scanners, select the appropriate handler according to the following table, and
click Next.
Scanner

Handler

PCTEL LX GSM 1800

PCTEL LX GSM 1800

PCTEL LX GSM 1900

PCTEL LX GSM 1900

PCTEL LX GSM 850

PCTEL LX GSM 850

PCTEL LX GSM 850/1900

PCTEL LX GSM 850/1900

PCTEL LX GSM 900

PCTEL LX GSM 900

PCTEL LX GSM 900/1800

PCTEL LX GSM 900/1800

PCTEL LX UMTS 1700/2100

PCTEL LX UMTS 1700/2100
PCT EL

84

PCTEL LX UMTS 1900

PCTEL LX UMTS 1900

PCTEL LX UMTS 2100

PCTEL LX UMTS 2100

PCTEL LX UMTS 850/1900

PCTEL LX UMTS 850/1900

PCTEL LX UMTS 850

PCTEL LX UMTS 850

PCTEL LX CDMA/EVDO 850

PCTEL LX EVDO 800

PCTEL LX 1xEVDO 450

PCTEL LX EVDO 450

PCTEL LX 1xEVDO 850

PCTEL LX EVDO 800

PCTEL LX 1xEVDO 1900

PCTEL LX EDVO 1900

PCTEL LX 1xEVDO 800/1900

PCTEL LX EDVO 800/1900

PCTEL EX CDMA/EVDO 850/1900

PCTEL EX CDMA2000 850/1900 EVDO
850/1900

PCTEL EX GSM 850/1900 & WCDMA 850/1900

PCTEL EX GSM 850/1900 UMTS
850/1900

PCTEL EX GSM 900/1800 & WCDMA 900/2100

PCTEL EX GSM 900/1800 UMTS
900/2100

PCTEL EX GSM 900/1800 & WCDMA 2100

PCTEL EX GSM 900/1800 UMTS 2100

PCTEL EX GSM 1900 & WCDMA 2100 AWS

PCTEL EX GSM 1900 UMTS AWS

PCTEL EX WIMAX

PCTEL EX WIMAX

PCTEL EX 900/1800 WCDMA/TD-SCDMA 2000

PCTEL EX 900/1800 UMTS TDSCDMA
2000

PCTEL EX WCDMA 2100 AWS&GSM 850/ 1900

PCTEL EX GSM 850/1900 UMTS AWS

PCTEL EX LTE 700ABC

PCTEL EX LTE 700ABC

PCTEL EX LTE 700ABC/Upper 700C/AWS

PCTEL EX LTE 700ABC/Upper
700C/AWS

PCTEL EX LTE 700C

PCTEL EX LTE 700C

PCTEL EX LTE AWS/700BC

PCTEL EX LTE AWS/700BC

PCTEL EX LTE AWS/700C

PCTEL EX LTE AWS/700C

PCTEL EX LTE 800

PCTEL EX LTE 800

PCTEL EX LTE 800/2600

PCTEL EX LTE 800/2600

PCTEL EX LTE 1600

PCTEL EX LTE 1600

PCTEL EX LTE 1800/2600

PCTEL EX LTE 1800/2600

PCTEL EX LTE 2100

PCTEL EX LTE 2100

PCTEL EX LTE 2100/2600

PCTEL EX LTE 2100/2600

PCTEL EX LTE 2600

PCTEL EX LTE 2600

PCTEL EX LTE AWS

PCTEL EX LTE AWS
PCT EL

85

PCTEL EX Mini series scanners:
•

WCDMA 2100

PCTEL EX UMTS 2100

•

WCDMA 850/1900

PCTEL EX UMTS 850/1900

•

WCDMA 900/2100

PCTEL EX UMTS 900/2100

•

WCDMA AWS

PCTEL EX UMTS AWS

PCTEL MX

PCTEL MX

PCTEL PCT GSM 900/1800

PCTEL PCT GSM 900/1800

PCTEL PCT UMTS 2100

PCTEL PCT UMTS 2100

5. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to.
With MX scanners, select the PCTEL USB item.
6. Set the baud rate to the one used by the scanner and click OK. The dialog will be closed and
the scanner should now be connected to the system.
7. If the dialog did not close, the start-up did not succeed. Check the cable connections and the
settings and try again.
8. From the View menu activate Device Status. A check mark will appear next to the
command when it is activated.
9. A green light on the PCTEL scanner in the Device Status window should be blinking. This
means that the device is working properly and scanning using the default settings. See
chapter Starting Measurement (page 125) for instructions on making your own scanner
configuration.
PCT EL

∇

86

Enabling integrated GPS receiver for PCTEL LX WCDMA/PCTEL EX
WiMAX scanner
1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog click the Advanced button.
3. In the Advanced Properties dialog, select Yes for the Enable Integrated GPS Receiver
option and click OK.

4. The integrated GPS receiver is now enabled.
♦

Note that you cannot use both the integrated and an external GPS receiver at the same
time.

♦

Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be
activated only with UMTS mode.

♦

To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix
at least 30 seconds before starting the Nemo Outdoor application in online mode. If the
existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the
configuration file in offline mode. If scanner does not send any results after 30 seconds,
it is advised to send a reset command to the scanner via the user interface.
PCT EL

∇

87

Starting the PCTEL LX GSM/WCDMA dual-mode scanner
1. Start Nemo Outdoor. Do not load any previous device configuration if asked.
2. From the Measurement menu, select Add New Device.
3. Click on Scanner.
4. From the list select PCTEL LX GSM 900/1800 and click Next.

5. In the Scanner Properties dialog, Port field you should see two consecutive COM ports
(e.g., COM 3 and COM 4). Select the COM port with the smaller number and click OK.
6. From the Measurement menu, select Add New Device. Click on Scanner.
7. From the list select PCTEL LX UMTS 2100 and click Next.
8. In the Scanner Properties dialog, Port field you should see two consecutive COM ports
(e.g., COM 3 and COM 4). Select the COM port with the bigger number and click OK.
9. A green light should be blinking in the Device Status for both devices. This means that the
devices are working properly and scanning using the default settings. If the status field
displays, Device is not started, check that you are in online mode (click the Work
).
Offline/Online button
10. The GSM and UMTS scanners will appear as separate devices and must be configured
individually.
PCT EL

∇
♦

88

Enabling integrated GPS receiver for PCTEL LX GSM/WCDMA dual-mode
scanner
Note that with the PCTEL dual-mode scanner the integrated GPS receiver needs to be
enabled only for one scanner.
1. After the PCTEL LX scanners are connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog click the Advanced button.
3. In the Advanced Properties dialog, select Yes in the Enable Integrated GPS Receiver
option and click OK.

4. The integrated GPS receiver is now enabled.
♦

Note that you cannot use both the integrated and an external GPS receiver at the same
time.

♦

Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be
activated only with UMTS mode.
PCT EL

89

MEASURING WITH PCTEL SCANNERS
Frequency Scanning – PCTEL GSM/UMTS Scanners
Frequency scanning can be used to scan band power. It is also useful for checking that the
band is deselected and for finding out the center frequency.
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. In the Measurement Properties dialog, go to the Frequency scanning, UMTS page.

3. In the Channel style field, select the channel width. The options are narrow band (200 kHz)
and wide band (3.84 MHz).
♦

To find out the center frequency used, set the Channel Style to 200 kHz and select all the
channels in the frequency region where the carrier should exist; for example, all channels
allocated to an operator. The center frequency will stand out in Frequency Scanning
mode. The received signal should be above the noise level in order to find out the center
frequency.
PCT EL

90

4. Click the Select Channels button to open the Select Channels dialog.

5. The table displays the channel numbers, not the frequencies.
6. Remove channels from the Selected list by selecting a channel and clicking the Remove
button.
7. Add channels to the Selected list by selecting a channel from the Available list and clicking
the Add button.
8. Click OK to return to the Measurement Properties dialog.
9. Click OK and OK to close the Measurement Properties dialog and to re-start the scanner
with the new settings.
10. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
11. Click the Start Recording button

to start recording the results in an output file.
PCT EL

91

Frequency Scanning – PCTEL EX LTE Scanner
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties. By clicking
the Advanced button on the General page, you will access the Advanced Properties
dialog. Here you can enable and disable the integrated GPS receiver. This means you will
not need an external GPS receiver in order to collect position data.
2. On the Frequency scanning page, define the Channel style.
PCT EL

92

3. By clicking the Select Channels button, you can access the Select Channels dialog.

4. Select one band from the list or all of them. You can also select one band at a time and add
the bands you want to scan. If all bands are selected, you have the possibility to select
Remove All | ... items from every band. Alternatively, if only one band is selected you can
remove only items from the current band through Remove All | ...items from current band.
The Available view provides a list of channels that are available for scanning. To add
channels to the Selected list, click on a number in the Available list and then click the Add
button or simply double-click a channel to add it to the Selected list. To select all available
channels for scanning, click the Add All button. An alternative method to select channels is
to type the channel numbers in the field at the bottom of the dialog and to click Add.
To remove channels from the Selected list, click on the channel you want to remove and
then click the Remove button or double-click the channel. To remove all channels, click the
Remove All button. You can select several channels simultaneously by holding down the
SHIFT key and clicking on the channels you want to add or remove.
5. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
6. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
7. Click the Start Recording button

to start recording the results in an output file.
PCT EL

93

Frequency Scanning – PCT GSM Scanner
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
3. Go to the Frequency scanning page.

Channel style refers to the style of the channel.
Selecting the BSIC decoding option displays BSIC value in a measurement window.
BSIC threshold defines the minimum BSIC level that the scanner reports.
Select the BCCH C/I option to activate C/I measurements for the BCCH channel. This option is
available with PCTEL GSM scanners only.
PCT EL

94

4. By clicking the Select Channels button, you can access the Select Channels dialog.

5. Select one band from the list or all of them. You can also select one band at a time and add
the bands you want to scan. If all bands are selected, you have the possibility to select
Remove All | ... items from every band. Alternatively, if only one band is selected you can
remove only items from the current band through Remove All | ...items from current band.
The Available view provides a list of channels that are available for scanning. To add
channels to the Selected list, click on a number in the Available list and then click the Add
button or simply double-click a channel to add it to the Selected list. To select all available
channels for scanning, click the Add All button. An alternative method to select channels is
to type the channel numbers in the field at the bottom of the dialog and to click Add.
To remove channels from the Selected list, click on the channel you want to remove and
then click the Remove button or double-click the channel. To remove all channels, click the
Remove All button. You can select several channels simultaneously by holding down the
SHIFT key and clicking on the channels you want to add or remove.
♦

Note that Sample size and Data mode are not enabled with PCT GSM frequency scanning
PCT EL

95

6. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
7. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
8. Click the Start Recording button

to start recording the results in an output file.

Frequency Scanning – PCTEL CDMA/EVDO Scanners
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
3. Go to the Frequency scanning page.

Channel style refers to the style of the channel. For EVDO scanners, the options are 1250 kHz
Normal and 30 kHz Normal.
Sample size defines the number of samples taken from each channel before a measurement
result is written to file.
PCT EL

96

4. By clicking the Select Channels button, you can access the Select Channels dialog.

5. Select one band from the list or all of them. You can also select one band at a time and add
the bands you want to scan. If all bands are selected, you have the possibility to select
Remove All | ... items from every band. Alternatively, if only one band is selected you can
remove only items from the current band through Remove All | ...items from current band.
The Available view provides a list of channels that are available for scanning. To add
channels to the Selected list, click on a number in the Available list and then click the Add
button or simply double-click a channel to add it to the Selected list. To select all available
channels for scanning, click the Add All button. An alternative method to select channels is
to type the channel numbers in the field at the bottom of the dialog and to click Add.
To remove channels from the Selected list, click on the channel you want to remove and
then click the Remove button or double-click the channel. To remove all channels, click the
Remove All button. You can select several channels simultaneously by holding down the
SHIFT key and clicking on the channels you want to add or remove.
6. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
7. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
8. Click the Start Recording button

to start recording the results in an output file.
PCT EL

97

TOP-N Pilot Scanning - UMTS
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode.
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. Go to the Pilot scanning page.

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are
below the threshold, the pilots are not reported.
Channel style refers to the style of the channel.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Pilot measurement mode defines the measurement mode for pilot scanning.
•

In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,
weak pilots may be undetected.

•

In High dynamic mode scanning speed is lower but sensitivity is higher.
PCT EL

98

Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode.
Time of arrival defines if the selected scanner will measure the time of arrival for each
scrambling code. The time of arrival value is relative to GPS time and is measured in chips.
Delay spread defines if the selected scanner will also measure the delay spread value (in
chips) for each scanned scrambling code. Delay spread is determined as the difference
between the last and first component to break the threshold set in PN Threshold.
P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling
code.
SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for
each scrambling code.
S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling
code.

∇

To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N
Configuration button. The Select Channels dialog is opened.

♦

The table displays the channel numbers, not the frequencies. If you know the frequency
but not the channel number, the channel number can be calculated by multiplying the
frequency in MHz by five. The channel spacing is always 200 kHz.
2. Remove channels from the Selected list by selecting a channel and clicking the Remove
button.
3. Add channels to the Selected list by selecting a channel from the Available list and clicking
the Add button.

♦

With a PCTEL LX scanner a maximum of 8 channels can be selected in the pilot mode.

♦

With a PCTEL EX scanner a maximum of 15 channels can be selected in the pilot mode.

♦

With a PCTEL MX scanner 1 channel can be selected in the pilot mode.

♦

With a PCTEL LTE EX scanner a maximum of 15 channels can be selected in the pilot mode.

♦

With a PCTEL PCT scanner a maximum of 4 channels can be selected in the pilot mode.
4. Click OK to return to the Measurement Properties dialog.

∇

To select pilot parameters:
1. Select the TOP-N Mode option.
2. Set the Number of scrambling codes value. This defines how many strongest pilots are to
be reported by the scanner. The maximum is 32 pilots.

♦

Note that with the PCTEL PCT Scanner the maximum number of pilots to be selected for
scanning is 8.
PCT EL

♦

99

Note that the PCTEL EX WCDMA scanner only supports the TOP-N mode. You can select
up to 32 pilots for scanning.
3. To improve on the accuracy of radio propagation models, High speed mode makes it
possible to acquire more samples (max 32 pilots per channel), while High dynamic mode
offers fewer samples (max 16 pilots per channel) with a larger dynamic range.

∇

To set general parameters:
1. Data processing method defines how the scanner will process samples before reporting.
2. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data
processing method is used.

∇

To select measured values:

♦

In Pilot Scanning Mode the RSSI is always measured for each channel.

♦

In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
1. In the Measurement Properties, Pilot scanning page:
•
•
•
•
•
•

Select the P-SCH option to enable P-SCH Ec/N0 and RSCP measurement.
Select the S-SCH option to enable S-SCH Ec/N0 and RSCP measurement.
Select the Time of arrival option to enable time of arrival measurement.
Select the Delay spread option to enable P-CPICH delay spread measurement.
Select the SIR option to enable P-CPICH SIR measurement.
Select the Delay profile option to enable P-CPICH Delay Profile measurement. In TOPN pilot scanning mode the scrambling code for delay profile measurement cannot be
selected.
2. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
3. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
4. Click the Start Recording button

to start recording the results in an output file.

TOP-N Pilot Scanning – CDMA/EVDO
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode.
1. After the PCTEL LX/EX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
PCT EL

10 0

3. In the Measurement Properties dialog, go to Pilot scanning page.

Channel style refers to the style of the channel.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Pilot window mode defines the position of the chips that are searched for pilot across in regard
to the ideal pilot position (0 chip delay for a given pilot).
Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1,
1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every
th
th
second sample is logged, with ratio 1:4 every 4 sample is logged, and with ratio 1:8 every 8
sample is logged. By decreasing the sampling ratio you can decrease the output file size, but
the scanning accuracy will be diminished.
Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the
threshold, the pilots are not scanned.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode.
PCT EL

10 1

Delay option enables/disables delay profile scanning. Delay is defined as the measured
difference between the expected arrival time (GPS time) and the actual arrival time of the
maximum peak above the PN threshold. It is reported in chips.
4. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
5. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
6. Click the Start Recording button

to start recording the results in an output file.

Spectrum Scanning
♦

Spectrum scanning is enabled on PCTEL EX scanners only in online mode. Hence, the
device needs to be added to Nemo Outdoor in online mode to activate the Spectrum
scanning functionality
1. After the PCTEL EX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Spectrum scanning page.
PCT EL

10 2

3. Select the Enable spectrum scanning option, and click Add.

4. To create new scanning sets, define the scanning frequencies in the Reporting view.
Set start and stop frequencies defines the frequency range that will be scanned.
Set center frequency and bandwidth defines the frequency range that will be scanned.
The Sample count field determines the sample count measured for the given frequency range.
5. The Add to Scanning List menu enables you to decide whether the new scanning set is
added to the scanning list, or saved as a predefined set also for later use.
6. The Predefined scanning sets can be used to quickly select the frequency range to be
scanned. Select a set from the list, and click on Add to Scanning List.
With PCTEL EX scanning receivers, the internal frequency range is defined with start
frequency, resolution bandwidth (RBW) and number of points. Stop frequency = start frequency
+ (frequency spacing) * (number of points – 1). All the points need to be within the frequency
range of the requested RF Band. Frequency spacing is between the center frequencies and
spacing between points is half of the resolution bandwidth. The maximum number of samples
(points) is 2560. As seen in the formula above, stop frequency is calculated based on start
frequency and number of points. Stop frequency set by the user is only requested value but it is
not necessarily used during the measurement.
PCT EL

10 3

If the requested frequency range is not supported by the device, Nemo Outdoor automatically
adjusts the frequency range for the device, and only frequency ranges supported by the
scanning receiver are used to make spectrum analyzer measurements. The number of samples
is used only for the frequency range supported by the scanning receiver. Nemo Outdoor does
not read the supported frequency range from the scanning receiver. For example, in the picture
below the user has set start and stop frequencies as seen within the red area. However, the
scanning receiver supports only frequency ranges shown by the green areas. The number of
samples is used only for green areas and the correct RBW is selected accordingly.

7. Click OK to return to the Spectrum scanning page.
PCT EL

10 4

8. The added frequency ranges will be added to the Scanning list.

9. To remove items from the scanning list, select one or more, and select Remove All |
Remove Selected Items. Alternatively, click on Remove All to remove every item from the
list.
10. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
11. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
12. Click the Start Recording button

to start recording the results in an output file.
PCT EL

10 5

LTE OFDM Scanning
OFDM scanning can be used for scanning Reference signal / Sync signals with a PCTEL
LTE scanner and Nemo Outdoor.
1. After the PCTEL LTE scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
3. In the Measurement Properties dialog, go to the Pilot scanning page.

Channel style refers to the style of the channel.
Cyclic prefix defines the type of signal the scanner is set to measure. With Autodetect
selected, the scanner will automatically detect the appropriate signal type.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
PCT EL

10 6

Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1,
1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every
th
th
second sample is logged, with ratio 1:4 every 4 sample is logged, and with ratio 1:8 every 8
sample is logged. By decreasing the sampling ratio you can decrease the output file size, but
the scanning accuracy will be diminished.
RSSI threshold determines a valid path (in dB). Subtracting the set value from a path with a
maximum correlation value gives the lower limit of the valid path.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best cells. Number of cells field indicates the number of best cells you want the
scanning to notify you of. Up to 16 sectors are reported with specific cell ID.
CINR option activates/deactivates Carrier to Interference and Noise Ratio measuring. Carrier
refers to either reference signal power or sync signal power depending on the selected signal
type.
Time offset refers to the number of samples between P-SCH Primary Synchronization Signal
arrival time with respect to receiver frequency reference that is derived from GPS reference
time.
Sync signal refers to the ratio between the synchronization channel, i.e., primary and
secondary signal received power and the interference and noise from the same synchronization
signal set.
Reference signal refers to the ratio between the reference signal received power (RSRP) and
the interference and noise from the same reference signal set.
The Top-N Configuration button will open the Select Channels where you can select
channels for pilot scanning. The maximum number of channels that can be selected is device
specific.
PCT EL

10 7

4. When you select LTE channels, you can also define some channel-specific settings. In the
LTE Channel Specific Settings dialog, select the channel from the Selected channels list
and define the settings.
♦

Note that the available options are device specific.

Uplink-downlink configuration refers to LTE TDD frame structure.
Frame structure type 2 is applicable to TDD. Each radio frame of length Tf = 307200 ⋅ Ts = 10 ms
consists of two half-frames of length 153600 ⋅Ts = 5 ms each. Each half-frame consists of five
subframes of length 30720 ⋅Ts = 1 ms . The supported uplink-downlink configurations are listed in
the table below where, for each subframe in a radio frame, “D” denotes the subframe is
reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink
transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One radio frame, Tf = 307200Ts = 10 ms
One half-frame, 153600Ts = 5 ms

One slot,
Tslot=15360Ts

30720Ts

Subframe #0

Subframe #2

One
subframe,
30720Ts
DwPTS

GP

Subframe #3

Subframe #4

Subframe #7

Subframe #5

UpPT
S

DwPTS

GP

Subframe #8

Subframe #9

UpPT
S

Frame structure type 2 (for 5 ms switch-point periodicity):
Uplink-downlink
configuration

Downlink-to-Uplink
Switch-point periodicity

0

1

2

Subframe number
3 4 5 6 7

8

9
PCT EL

10 8

0
1
2
3
4
5
6

5 ms
5 ms
5 ms
10 ms
10 ms
10 ms
5 ms

D
D
D
D
D
D
D

S
S
S
S
S
S
S

U
U
U
U
U
U
U

U
U
D
U
U
D
U

U
D
D
U
D
D
U

D
D
D
D
D
D
D

S
S
S
D
D
D
S

U
U
U
D
D
D
U

U
U
D
D
D
D
U

U
D
D
D
D
D
D

5. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
6. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
7. Click the Start Recording button

to start recording the results in an output file.

Pilot Scrambling Code Scanning
Known Scrambling Code Scanning can be used to scan known pilots. The Known Scrambling
Code Scanning will from now on be referred to as Normal Pilot Mode.
1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual
Nemo fsr1 scanner user manual

Mais conteúdo relacionado

Mais procurados

Routing over ericsson mini link
Routing over ericsson mini linkRouting over ericsson mini link
Routing over ericsson mini linkAhmed Nabeeh
 
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2Mohamed Abd El Razek Bakry
 
SCFT-Training_v8.2-1
SCFT-Training_v8.2-1SCFT-Training_v8.2-1
SCFT-Training_v8.2-1mahesh savita
 
config_mini link
config_mini linkconfig_mini link
config_mini linkAmir Moradi
 
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdfluckychandel2
 
3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSN
3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSN3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSN
3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSNibrahimnabil17
 
How to build a DMR Simulcast Network
How to build a DMR Simulcast NetworkHow to build a DMR Simulcast Network
How to build a DMR Simulcast NetworkLeonardo
 
Huawei RET alarms Troubleshooting Guide Flow Chart
Huawei RET alarms Troubleshooting Guide   Flow Chart Huawei RET alarms Troubleshooting Guide   Flow Chart
Huawei RET alarms Troubleshooting Guide Flow Chart Mohamed Abd El Razek Bakry
 
Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...
Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...
Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...Small Cell Forum
 
Xpic implementation xpd alignment interference test
Xpic implementation xpd alignment interference testXpic implementation xpd alignment interference test
Xpic implementation xpd alignment interference testKhalil Al-Alami
 
Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...
Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...
Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...Michael Gronovius
 
LTE RADIO PROTOCOLS
LTE RADIO PROTOCOLSLTE RADIO PROTOCOLS
LTE RADIO PROTOCOLSbrkavyashree
 
BBU6102 Maintenance_CLU.pdf
BBU6102 Maintenance_CLU.pdfBBU6102 Maintenance_CLU.pdf
BBU6102 Maintenance_CLU.pdfhassan874147
 
3GPP SON Series: Mobility Load Balancing (MLB)
3GPP SON Series: Mobility Load Balancing (MLB)3GPP SON Series: Mobility Load Balancing (MLB)
3GPP SON Series: Mobility Load Balancing (MLB)3G4G
 
494197038-Baseband-6648-Commercial-Presentation.pdf
494197038-Baseband-6648-Commercial-Presentation.pdf494197038-Baseband-6648-Commercial-Presentation.pdf
494197038-Baseband-6648-Commercial-Presentation.pdfmehdiberenji
 

Mais procurados (20)

Routing over ericsson mini link
Routing over ericsson mini linkRouting over ericsson mini link
Routing over ericsson mini link
 
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
 
SCFT-Training_v8.2-1
SCFT-Training_v8.2-1SCFT-Training_v8.2-1
SCFT-Training_v8.2-1
 
config_mini link
config_mini linkconfig_mini link
config_mini link
 
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
 
3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSN
3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSN3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSN
3G BTS and DBS Hardware at Ericsson, Huawei, ZTE and NSN
 
How to build a DMR Simulcast Network
How to build a DMR Simulcast NetworkHow to build a DMR Simulcast Network
How to build a DMR Simulcast Network
 
Huawei RET alarms Troubleshooting Guide Flow Chart
Huawei RET alarms Troubleshooting Guide   Flow Chart Huawei RET alarms Troubleshooting Guide   Flow Chart
Huawei RET alarms Troubleshooting Guide Flow Chart
 
Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...
Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...
Ibwave The in building wireless standard: INNOVATIVE PLANNING OF SMALL CELL N...
 
Xpic implementation xpd alignment interference test
Xpic implementation xpd alignment interference testXpic implementation xpd alignment interference test
Xpic implementation xpd alignment interference test
 
Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...
Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...
Reducing RAN infrastructure resources by leveraging 5G RAN Transport Technolo...
 
LTE RADIO PROTOCOLS
LTE RADIO PROTOCOLSLTE RADIO PROTOCOLS
LTE RADIO PROTOCOLS
 
BBU6102 Maintenance_CLU.pdf
BBU6102 Maintenance_CLU.pdfBBU6102 Maintenance_CLU.pdf
BBU6102 Maintenance_CLU.pdf
 
3GPP SON Series: Mobility Load Balancing (MLB)
3GPP SON Series: Mobility Load Balancing (MLB)3GPP SON Series: Mobility Load Balancing (MLB)
3GPP SON Series: Mobility Load Balancing (MLB)
 
Introduction of dmvpn
Introduction of dmvpnIntroduction of dmvpn
Introduction of dmvpn
 
Unified MPLS
Unified MPLSUnified MPLS
Unified MPLS
 
4g interview-question
4g interview-question4g interview-question
4g interview-question
 
Training.ppt
Training.pptTraining.ppt
Training.ppt
 
494197038-Baseband-6648-Commercial-Presentation.pdf
494197038-Baseband-6648-Commercial-Presentation.pdf494197038-Baseband-6648-Commercial-Presentation.pdf
494197038-Baseband-6648-Commercial-Presentation.pdf
 
Lte most used command rev1
Lte most used command rev1Lte most used command rev1
Lte most used command rev1
 

Destaque

Tems investigation 13.1 release note
Tems investigation 13.1 release noteTems investigation 13.1 release note
Tems investigation 13.1 release notetelecom_200
 
Take a ride through a subway's wireless network design
Take a ride through a subway's wireless network designTake a ride through a subway's wireless network design
Take a ride through a subway's wireless network designiBwave
 
NEDAS DC Educational Summit - the Era of Convergence - Presentation Deck
NEDAS DC Educational Summit - the Era of Convergence - Presentation DeckNEDAS DC Educational Summit - the Era of Convergence - Presentation Deck
NEDAS DC Educational Summit - the Era of Convergence - Presentation DeckIlissa Miller
 
Project NEMO - towards empathy-enabling digital environments
Project NEMO - towards empathy-enabling digital environmentsProject NEMO - towards empathy-enabling digital environments
Project NEMO - towards empathy-enabling digital environmentsKatri Saarikivi
 
How to perform walktest from nemo outdoor
How to perform walktest from nemo outdoor How to perform walktest from nemo outdoor
How to perform walktest from nemo outdoor Telebeansolutions
 
AZQ Android 2G/3G/4G Test Tool Presentation 2014
AZQ Android 2G/3G/4G Test Tool Presentation 2014AZQ Android 2G/3G/4G Test Tool Presentation 2014
AZQ Android 2G/3G/4G Test Tool Presentation 2014Don Plooksawasdi
 
Optimization Module Overview
Optimization Module OverviewOptimization Module Overview
Optimization Module OverviewiBwave Solutions
 
雲端產品的用戶體驗檢測重要性與作法
雲端產品的用戶體驗檢測重要性與作法雲端產品的用戶體驗檢測重要性與作法
雲端產品的用戶體驗檢測重要性與作法NTUST
 
RSCP RSSI EC/NO CQI
RSCP RSSI EC/NO CQIRSCP RSSI EC/NO CQI
RSCP RSSI EC/NO CQIFaraz Husain
 
ბანკები და ფინანსები #499
ბანკები და ფინანსები #499ბანკები და ფინანსები #499
ბანკები და ფინანსები #499BFM2015
 

Destaque (13)

Drive Test Nemo
Drive Test NemoDrive Test Nemo
Drive Test Nemo
 
Tems investigation 13.1 release note
Tems investigation 13.1 release noteTems investigation 13.1 release note
Tems investigation 13.1 release note
 
Take a ride through a subway's wireless network design
Take a ride through a subway's wireless network designTake a ride through a subway's wireless network design
Take a ride through a subway's wireless network design
 
NEDAS DC Educational Summit - the Era of Convergence - Presentation Deck
NEDAS DC Educational Summit - the Era of Convergence - Presentation DeckNEDAS DC Educational Summit - the Era of Convergence - Presentation Deck
NEDAS DC Educational Summit - the Era of Convergence - Presentation Deck
 
Project NEMO - towards empathy-enabling digital environments
Project NEMO - towards empathy-enabling digital environmentsProject NEMO - towards empathy-enabling digital environments
Project NEMO - towards empathy-enabling digital environments
 
Nemo
NemoNemo
Nemo
 
How to perform walktest from nemo outdoor
How to perform walktest from nemo outdoor How to perform walktest from nemo outdoor
How to perform walktest from nemo outdoor
 
AZQ Android 2G/3G/4G Test Tool Presentation 2014
AZQ Android 2G/3G/4G Test Tool Presentation 2014AZQ Android 2G/3G/4G Test Tool Presentation 2014
AZQ Android 2G/3G/4G Test Tool Presentation 2014
 
Optimization Module Overview
Optimization Module OverviewOptimization Module Overview
Optimization Module Overview
 
Lte drive test parameters
Lte drive test parametersLte drive test parameters
Lte drive test parameters
 
雲端產品的用戶體驗檢測重要性與作法
雲端產品的用戶體驗檢測重要性與作法雲端產品的用戶體驗檢測重要性與作法
雲端產品的用戶體驗檢測重要性與作法
 
RSCP RSSI EC/NO CQI
RSCP RSSI EC/NO CQIRSCP RSSI EC/NO CQI
RSCP RSSI EC/NO CQI
 
ბანკები და ფინანსები #499
ბანკები და ფინანსები #499ბანკები და ფინანსები #499
ბანკები და ფინანსები #499
 

Semelhante a Nemo fsr1 scanner user manual

Nemofsr1scannerusermanual 140112215831-phpapp01
Nemofsr1scannerusermanual 140112215831-phpapp01Nemofsr1scannerusermanual 140112215831-phpapp01
Nemofsr1scannerusermanual 140112215831-phpapp01Ha Thanh
 
159898575 nemo-fsr1-3-01-user-manual
159898575 nemo-fsr1-3-01-user-manual159898575 nemo-fsr1-3-01-user-manual
159898575 nemo-fsr1-3-01-user-manualPhi Fei
 
싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼HION IT
 
UserGuide-DKAGPS-1_um_1v0.pdf
UserGuide-DKAGPS-1_um_1v0.pdfUserGuide-DKAGPS-1_um_1v0.pdf
UserGuide-DKAGPS-1_um_1v0.pdfMucussete Abudo
 
Lumiring Technology - Infinity Manual
Lumiring Technology - Infinity ManualLumiring Technology - Infinity Manual
Lumiring Technology - Infinity ManualLumiRing
 
Aemp-14 use with rtk gps system
Aemp-14  use with rtk gps systemAemp-14  use with rtk gps system
Aemp-14 use with rtk gps systemLandviser LLC
 
Voice Primer Lab.pdf
Voice Primer Lab.pdfVoice Primer Lab.pdf
Voice Primer Lab.pdfacaldere
 
3 g rf_optimisation_basics
3 g rf_optimisation_basics3 g rf_optimisation_basics
3 g rf_optimisation_basicsMd.Akm Sahansha
 
Outdoor 4G LTE CPE Installation Guide
Outdoor 4G LTE CPE Installation GuideOutdoor 4G LTE CPE Installation Guide
Outdoor 4G LTE CPE Installation GuideTerence Yong
 
싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼HION IT
 

Semelhante a Nemo fsr1 scanner user manual (20)

Nemofsr1scannerusermanual 140112215831-phpapp01
Nemofsr1scannerusermanual 140112215831-phpapp01Nemofsr1scannerusermanual 140112215831-phpapp01
Nemofsr1scannerusermanual 140112215831-phpapp01
 
159898575 nemo-fsr1-3-01-user-manual
159898575 nemo-fsr1-3-01-user-manual159898575 nemo-fsr1-3-01-user-manual
159898575 nemo-fsr1-3-01-user-manual
 
싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1560P 1D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
 
UserGuide-DKAGPS-1_um_1v0.pdf
UserGuide-DKAGPS-1_um_1v0.pdfUserGuide-DKAGPS-1_um_1v0.pdf
UserGuide-DKAGPS-1_um_1v0.pdf
 
Sokkia sdr-8100 operations manual
Sokkia sdr-8100 operations manualSokkia sdr-8100 operations manual
Sokkia sdr-8100 operations manual
 
Plr5000
Plr5000Plr5000
Plr5000
 
CATV Optical Transmitter
CATV Optical TransmitterCATV Optical Transmitter
CATV Optical Transmitter
 
Lumiring Technology - Infinity Manual
Lumiring Technology - Infinity ManualLumiring Technology - Infinity Manual
Lumiring Technology - Infinity Manual
 
Aemp-14 use with rtk gps system
Aemp-14  use with rtk gps systemAemp-14  use with rtk gps system
Aemp-14 use with rtk gps system
 
Voice Primer Lab.pdf
Voice Primer Lab.pdfVoice Primer Lab.pdf
Voice Primer Lab.pdf
 
Air Gate Max Userguide
Air Gate Max UserguideAir Gate Max Userguide
Air Gate Max Userguide
 
3 g rf_optimisation_basics
3 g rf_optimisation_basics3 g rf_optimisation_basics
3 g rf_optimisation_basics
 
SDS_SSL_MPM_UN_A4
SDS_SSL_MPM_UN_A4SDS_SSL_MPM_UN_A4
SDS_SSL_MPM_UN_A4
 
Outdoor 4G LTE CPE Installation Guide
Outdoor 4G LTE CPE Installation GuideOutdoor 4G LTE CPE Installation Guide
Outdoor 4G LTE CPE Installation Guide
 
Dp s7300
Dp s7300Dp s7300
Dp s7300
 
싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
싸이퍼랩스캐너 CipherLab 1564A 2D스캐너 산업용스캐너 바코드스캐너 블루투스스캐너 매뉴얼
 
Lightspeed ii-manual-2012-jan
Lightspeed ii-manual-2012-janLightspeed ii-manual-2012-jan
Lightspeed ii-manual-2012-jan
 
Gpsuav2 manual v29
Gpsuav2 manual v29Gpsuav2 manual v29
Gpsuav2 manual v29
 
final ppt2.pptx
final ppt2.pptxfinal ppt2.pptx
final ppt2.pptx
 
SigfoxMakersDay Total
SigfoxMakersDay TotalSigfoxMakersDay Total
SigfoxMakersDay Total
 

Último

Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Developing An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of BrazilDeveloping An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of BrazilV3cube
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...apidays
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProduct Anonymous
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoffsammart93
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationMichael W. Hawkins
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUK Journal
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsJoaquim Jorge
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
HTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesHTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesBoston Institute of Analytics
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 

Último (20)

Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Developing An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of BrazilDeveloping An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of Brazil
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
HTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesHTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation Strategies
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 

Nemo fsr1 scanner user manual

  • 2. © 2012 by Anite Finland Ltd. All rights reserved. This manual, as well as the software described in it, is furnished under license and may only be used or copied in accordance with the terms of such license. The information in this manual is intended for informational use only and is subject to change without notice. Anite Finland Ltd assumes no responsibility or liability for any errors or inaccuracies that may appear in this user manual. Except as permitted by such license, no part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Anite Finland Ltd. Windows®, Windows® XP, Windows® Vista, Windows® 7, Outlook®, and Internet Explorer are registered trademarks of the Microsoft® Corporation in the United States and other countries. MapInfo® and MapX® are registered trademarks of MapInfo® Corporation. CDMA 2000® is a registered trademark of the Telecommunications Industry Association (TIA -USA). The license management portion of this Licensed Technology is based on SentinelLM* © 1989-2003 Rainbow Technologies, Inc. All rights reserved. Revision 6.20.01, Last edited February 2012
  • 3. Nem o Sc an n er G u i de NEMO FSR1 CONNECTING NEMO FSR1 SCANNER Changing the Nemo FSR1 IP Address Connecting a GPS Antenna to Nemo FSR1 3 5 5 8 13 CONNECTING NEMO FSR1 SCANNER TO NEMO INVEX CHASSIS STARTING NEMO FSR1 SCANNER 16 NEMO FSR1 FIRMWARE UPDATE 17 MEASURING WITH NEMO FSR1 SCANNER Frequency Scanning TOP-N Pilot Scanning - UMTS TOP-N Pilot Scanning - CDMA/EVDO TOP-N Pilot Scanning – LTE Spectrum Analyzer Measurements Band Scan 18 18 20 23 24 27 30 CALIBRATING NEMO FSR1 14 32 ANRITSU 33 CONNECTING ANRITSU SCANNERS 33 Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer Scanner 37 STARTING ANRITSU SCANNERS 41 MEASURING WITH ANRITSU SCANNERS Frequency Scanning TOP-N Pilot Scanning - UMTS Pilot Scrambling Code Scanning DVB-H Scanning Spectrum Analyzer Measurements 42 42 45 51 53 54 DRT 57 CONNECTING THE DRT WIMAX 4301A+ SCANNER 57 STARTING DRT SCANNERS 60 MEASURING WITH DRT SCANNERS Frequency Scanning Pilot Scanning 62 62 64 PCTEL 67 CONNECTING PCTEL LX CDMA/EVDO/GSM/WCDMA SCANNER CONNECTING PCTEL EX SCANNERS 67 69 CONNECTING THE PCTEL LX GSM/WCDMA DUAL-MODE SCANNER CONNECTING THE PCTEL MX SCANNER 76 CONNECTING PCTEL PCT SCANNERS 73 79 CONNECTING PCTEL SCANNERS TO NEMO INVEX CHASSIS STARTING PCTEL SCANNERS 83 MEASURING WITH PCTEL SCANNERS 89 82
  • 4. Nem o Sc an n er G u i de 4 Frequency Scanning – PCTEL GSM/UMTS Scanners Frequency Scanning – PCTEL EX LTE Scanner Frequency Scanning – PCT GSM Scanner Frequency Scanning – PCTEL CDMA/EVDO Scanners TOP-N Pilot Scanning - UMTS TOP-N Pilot Scanning – CDMA/EVDO Spectrum Scanning LTE OFDM Scanning Pilot Scrambling Code Scanning ROHDE & SCHWARZ 89 91 93 95 97 99 101 105 108 110 CONNECTING THE ROHDE & SCHWARZ TSMQ/TSML SCANNER 110 CONNECTING THE ROHDE & SCHWARZ TSMW SCANNER113 System Priority Order with R&S TSMW Scanners 115 CONNECTING ROHDE & SCHWARZ SCANNERS TO NEMO INVEX CHASSIS Connecting R&S TSMW to Nemo Invex with an Ethernet Cable 118 Connecting R&S TSMW to Nemo Invex with a Network Switch 119 STARTING ROHDE & SCHWARZ SCANNERS 123 MEASURING WITH ROHDE & SCHWARZ SCANNERS Frequency Scanning TOP-N Pilot Scanning - UMTS TOP-N Pilot Scanning - CDMA/EVDO TOP-N Pilot Scanning - LTE Spectrum Scanning 125 125 127 129 131 134 TROUBLESHOOTING SCANNERS NEMO FSR1 137 137 117
  • 5. Nem o F S R1 5 NEMO FSR1 CONNECTING NEMO FSR1 SCANNER Nemo FSR1 scanner is powered by 10 to 16 VDC. AC operation for the standalone receiver is achieved by using the optional AC power supply. The AC power supply is designed to work with 100 - 240VAC 50/60Hz. For other voltages or line frequencies contact Anite for the correct supply. The standard AC supply is rated at 130 Watts. Actual power requirements will vary depending number of downconverters installed and the receiver tasking. The maximum power requirement of the scanner is 50 Watts. DC operation for the standalone receiver can be achieved by connection to a vehicle 12-volt system. The following table is provided to budget the system current requirements for various configurations. Platform configuration/Module 12 VDC current requirement Basic system w/ single downconverter 3.0 A Two downconverter system 3.6 A The estimates given for the scanner assume maximum utilization of the processing capabilities. ∇ Connecting the Nemo FSR1: 1. Connect an antenna cable to scanner RF input. If you are measuring with two downconverters, connect an antenna in both RF inputs (see picture below).
  • 6. Nem o F S R1 2. Connect Ethernet cable(s) to the scanner Ethernet port(s) and to the Nemo Outdoor laptop. 3. Go to Control Panel | Network and Internet | Network and Sharing Center. Click on Change adapter settings. 4. Right-click on Local Area Connection and select Properties. In the Local Area Connection Properties dialog, select Internet Protocol Version 4 (TCP/IPv4) and click Properties. 6
  • 7. Nem o F S R1 7 5. Select Use the following IP address and type in an IP address that is different from that of the scanner. The IP address should be 192.168.3.xxx where the xxx can be anything else except 250, 251, 252, or 253 because those four IP addresses are reserved for the scanner. Click OK and Close. ♦ Please note that by default the Nemo FSR1 is delivered with a fixed IP address. The IP address can be changed with a separate utility software. The following IP addresses are used in Nemo Outdoor: • "Nemo Scanner LAN" = 192.168.3.253 • "Nemo Scanner LAN 2" = 192.168.3.252 • "Nemo Scanner LAN 3" = 192.168.3.251 • "Nemo Scanner LAN 4" = 192.168.3.250
  • 8. Nem o F S R1 8 6. Connect the power cable to the scanner and to a power source. Switch power on. Fuse Power connector Fans Power switch 7. The default address and name settings of the scanner are generally suitable for most users. There is no need to configure these settings when using the Nemo FSR1 scanner with Nemo Outdoor. 8. The status LEDs at the front panel display how the scanner is functioning. LED Name RxA RxB Status Active All LEDs LED Color Green Amber Green Amber Green Amber Green Red Amber Description Receiver A enabled Receiver A disabled i.e. EEPROM not readable Receiver B enabled Receiver B disabled i.e. EEPROM not readable GPS Locked GPS Unlocked Ethernet link connected Ethernet link disconnected If all four LEDs are amber, the bootloader is running and the module needs to be reloaded Changing the Nemo FSR1 IP Address The default address and name settings of the Nemo FSR1 are generally suitable for most users. However, if you have two or more Nemo FSR1 scanners connected to the same measurement laptop, you will need to assign a different IP address for each scanner. By default, the Nemo FSR1 scanners are delivered with a fixed IP address: 192.168.3.253. When changing the IP address, please use the following IP addresses supported in Nemo Outdoor: • "Nemo Scanner LAN" = 192.168.3.253 • "Nemo Scanner LAN 2" = 192.168.3.252 • "Nemo Scanner LAN 3" = 192.168.3.251 • "Nemo Scanner LAN 4" = 192.168.3.250
  • 9. Nem o F S R1 Connect a PC to the Nemo FSR1 serial port using the serial adapter cable (available from Anite). The scanner serial port is located in the lower-right corner of the front panel. Switch on the scanner. Figure 1. Nemo FSR1 serial adapter cable ♦ If a serial port is not available on the computer, a USB-to-serial adapter can be used. Follow the manufacturer’s instructions for driver installation and use of the adapter. If an adapter is used, the COM port to choose for the Hyperterminal connection should be the port assigned by Windows to the USB/serial adapter (see Device Manager, Ports). Start a terminal port software, such as, HyperTerminal. Select COM1 or the port assigned to the USB/serial adapter in the Connect using field and click Configure. 9
  • 10. Nem o F S R1 In the COM1 Properties dialog, define the following settings: Bits per second: 115200 Data bits: 8 Parity: None Stop bits: 1 Flow control: Xon/Xoff Click OK and OK. An empty HyperTerminal window is opened. 10
  • 11. Nem o F S R1 Press Enter on your keyboard. The following information is displayed. To change the IP address, press 2 and Enter. Enter the new IP address in format xxx.xxx.xxx.xxx. For example, 192.168.003.252. Press Enter. 11
  • 12. Nem o F S R1 The IP address is changed and the window displays the new flash data with the new IP address. To update the scanner firmware and finalize the changes, press 0 and Enter. Confirm the firmware update by pressing Y and Enter. ♦ This is an important step to complete the firmware update. If you exit HyperTerminal without entering 0 and selecting Y when prompted, the firmware will not be updated. 12
  • 13. Nem o F S R1 13 The scanner firmware is updated and the scanner is restarted. Check from the scanner information that the IP address has changed. Now you can close the HyperTerminal. Connecting a GPS Antenna to Nemo FSR1 For optimum performance of the FSR1, it is strongly recommended to connect the GPS antenna to the scanner. The scanner takes advantage of GPS for timing information which improves the performance of the signal processing algorithms. Also note for CDMA/EVDO the scanner must have GPS coverage. If CDMA/EVDO in-building testing is to be conducted, the scanner should operate at least 30 minutes in GPS coverage before the antenna is disconnected and then every hour or two of walk testing have an additional 20 minutes in GPS coverage. The following GPS antenna is delivered with the Nemo FSR1: • Mighty Mouse III • 28dB gain low noise amplifier • Maximum of 6mA current consumption (all voltages) • 2.5V to 5.5V DC • Connector: SMA male Connect the GPS antenna cable to the GPS connector in the scanner front panel.
  • 14. Nem o F S R1 14 CONNECTING NEMO FSR1 SCANNER TO NEMO INVEX CHASSIS Nemo FSR1 is connected to the Nemo Invex chassis (SI module) with an Ethernet cable. Ethernet ports are located on the front panel of the Nemo FSR1 scanner and on the front panel of the Nemo Invex SI module. Nemo FSR1 front panel. Nemo Invex SI module front panel.
  • 15. Nem o F S R1 Nemo FSR1 power cable can be connected to the Nemo Invex chassis. The scanner power connector is located at the rear of the chassis. The Nemo FSR1 scanner can be attached on top of the Nemo Invex chassis with a mounting plate. 15
  • 16. Nem o F S R1 16 Clearance for air ventilation around the Nemo FSR1 is as follows: • 10 cm • Left side 3 cm • ♦ Back Right side 3 cm (not applicable for Rev B scanner) Note that the air intake is on the left side and exhaust on the back. STARTING NEMO FSR1 SCANNER 1. Start Nemo Outdoor. Do not load any previous device configuration if asked. 2. From the Measurement menu, select Add New Device. 3. Click on Scanner. 4. From the list select Nemo FSR1 and click Next.
  • 17. Nem o F S R1 5. In the Scanner Properties dialog, select Nemo Scanner LAN as the Port and click OK. 6. If the dialog did not close, the startup did not succeed. Check the cable connections and the settings and try again. 7. If the Device Status window is not visible, open it from the View menu. A green light should be blinking. This means that the device is working properly and scanning using the default settings. If the status field displays, Device is not started, check that you are in online mode (click the Work Offline/Online button ). If the device is started but not scanning, check that you have selected channels to be scanned. NEMO FSR1 FIRMWARE UPDATE Nemo FSR1 firmware can be updated using the Nemo FSR1 Firmware Update Utility or through Nemo Outdoor. For detailed information on using the update utility, please refer to the Nemo FSR1 Firmware Update Utility Instructions document. The scanner firmware can also be updated through Nemo Outdoor. Connect the scanner to Nemo Outdoor and then click the Measurement settings button in the Devices view. Select Update Firmware. 17
  • 18. Nem o F S R1 In the File field, browse the latest firmware update file (.ffw) and click Update. The update may take a few minutes. Do not switch off the scanner! When the update is complete, close the dialog and restart the scanner. MEASURING WITH NEMO FSR1 SCANNER Frequency Scanning 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog you can select the channels to be scanned. 18
  • 19. Nem o F S R1 19 3. On the Frequency scanning, GSM page, click the Select Channels button to select the GSM channels to be scanned. Channel style defines the style of the measured channel. For GSM the option is 200 kHz. Data mode defines the type of measurement data computed from each sample. Note that the available selection depends on the scanner type. • RX Level Average: the data reported is the average RX level, in dB, of the number of samples. Measurement period defines the time in milliseconds for which the scanner measures and then reports the result. Sample size defines the number of samples taken from each channel before a measurement result is written to file. Selecting the BSIC decoding option enables BSIC values and co-channel C/I measurements. BSIC threshold defines the minimum BSIC level that the scanner reports. Select the BCCH C/I option to activate BCCH decoding. Co-channel C/I is also enabled. Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID information can be decoded from BCCH messages. Note that this is only enabled in online mode and if the option has been purchased with the scanner.
  • 20. Nem o F S R1 20 When the System information decoding option is selected, L3 messages are written in the log file. 4. Click the Start Recording button to start recording the results in an output file. TOP-N Pilot Scanning - UMTS Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N pilot mode/scanning. ∇ To set pilot scanning settings: 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page. CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are below the threshold, the pilots are not reported. Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow Band (200kHz) and Wide Band (3.84MHz). Correlator parameter is no longer utilized by the FSR1 UMTS scanning algorithms. It is encouraged to set this parameter to the highest correlation value, 4096.
  • 21. Nem o F S R1 21 Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Measurement period defines the time in milliseconds for which the scanner measures and then reports the result. Pilot measurement mode defines the measurement mode for pilot scanning. • In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode, weak pilots may be undetected. • In High dynamic range mode scanning speed is lower but sensitivity is higher. Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode. The maximum number is 32. Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID information can be decoded from BCCH messages. Note that this is only enabled in online mode and if the option has been purchased with the scanner. Delay spread defines if the selected scanner will also measure the delay spread value (in chips) for each scanned scrambling code. Delay spread is determined as the difference between the last and first component to break the threshold set in PN Threshold. P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling code. S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling code. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning.
  • 22. Nem o F S R1 ∇ 22 To select channels: 1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N Configuration button. The Select Channels dialog is opened. 2. The table displays the channel numbers, not the frequencies. 3. You can remove channels from the Selected list by selecting a channel and clicking the Remove button. 4. You can add channels to the Selected list by selecting a channel from the Available list and clicking the Add button. 5. Click OK to return to the Measurement Properties dialog. 6. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 7. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 8. Click the Start Recording button to start recording the results in an output file.
  • 23. Nem o F S R1 TOP-N Pilot Scanning - CDMA/EVDO ♦ Note that the EVDO measurements can only be performed in a proper way when a CDMA2000 channel is measured as well. In this way, the time relationship between the different PN offsets is resolved. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning, CDMA page. Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow Band (200kHz) and Wide Band (3.84MHz). Correlator affects how the scanner works. Bigger correlator size enables the scanner to detect and measure pilot channels with better dynamic but makes scanning speed slower. For example, when using correlator size 2048 versus 512, the dynamic range for pilot measurement changes from –21db to –17db. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the threshold, the pilots are not scanned. 23
  • 24. Nem o F S R1 24 Top-N mode option enables/disables TOP-N scrambling code scanning. Number of pilots field defines how many pilots are reported by the scanner in TOP-N mode. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning. ♦ Note that the Nemo FSR1 scanner supports a max of 90 cell IDs. 3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 5. Click the Start Recording button to start recording the results in an output file. TOP-N Pilot Scanning – LTE 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. Go to the Pilot scanning, LTE page to define LTE-specific pilot scanning settings.
  • 25. Nem o F S R1 Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow Band (200kHz) and Wide Band (3.84MHz). Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. CINR refers to the Carrier to Interference and Noise ratio value, in dB *100 (e.g., -16.34). It is based on the requested reuse factor. Time offset refers to the number of samples between P-SCH Primary Synchronization Signal arrival time with respect to receiver frequency reference that is derived from GPS reference time. Sync signal refers to the ratio between the synchronization channel, i.e., primary and secondary signal received power and the interference and noise from the same synchronization signal set. Reference signal refers to the ratio between the reference signal received power (RSRP) and the interference and noise from the same reference signal set. When the System information decoding option is selected, L3 messages are written in the log file. The Select Channels button will open the Select Channels dialog where you can select channels for pilot scanning. When you select LTE channels, you can also define some channel-specific settings. In the LTE Channel Specific Settings dialog, select the channel from the Selected channels list and define the settings. ♦ Note that the available options are device specific. 25
  • 26. Nem o F S R1 26 Cyclic prefix defines the type of signal the scanner is set to measure. With Autodetect selected, the scanner will automatically detect the appropriate signal type. If Cyclic Prefix is known to be Normal (most common), setting the scanner to Normal will increase scanning speed slightly. Uplink-downlink configuration refers to LTE TDD frame structure. Frame structure type 2 is applicable to TDD. Each radio frame of length Tf = 307200 ⋅ Ts = 10 ms consists of two half-frames of length 153600 ⋅Ts = 5 ms each. Each half-frame consists of five subframes of length 30720 ⋅Ts = 1 ms . The supported uplink-downlink configurations are listed in the table below where, for each subframe in a radio frame, “D” denotes the subframe is reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS. One radio frame, Tf = 307200Ts = 10 ms One half-frame, 153600Ts = 5 ms One slot, Tslot=15360Ts 30720Ts Subframe #0 Subframe #2 One subframe, 30720Ts DwPTS GP Subframe #3 Subframe #5 Subframe #4 UpPT S Subframe #7 DwPTS GP Subframe #8 Subframe #9 UpPT S Frame structure type 2 (for 5 ms switch-point periodicity): Uplink-downlink configuration 0 1 2 3 4 5 6 Downlink-to-Uplink Switch-point periodicity 5 ms 5 ms 5 ms 10 ms 10 ms 10 ms 5 ms 0 D D D D D D D 1 S S S S S S S 2 U U U U U U U Subframe number 3 4 5 6 7 U U D S U U D D S U D D D S U U U D D D U D D D D D D D D D U U D S U 8 U U D D D D U 9 U D D D D D D 3. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 4. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 5. Click the Start Recording button to start recording the results in an output file.
  • 27. Nem o F S R1 Spectrum Analyzer Measurements 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Spectrum scanning page. Select the Enable spectrum scanning option and click on Add. 3. Define the start and stop frequencies within which the measurement will be performed. If you manually define the start and stop frequencies, you can either select to add the frequencies to the scanning list or save them as a predefined set. Select your option in the Add to scanning list menu. 4. Select Set center frequency and bandwidth to define the center frequency and the bandwidth to be measured. If you manually define the center frequency and bandwidth, you can either select to add them to the scanning list, or save them as a predefined set. Select your option in the Add to scanning list menu. 27
  • 28. Nem o F S R1 ♦ If the requested frequency range is not supported by the device, Nemo Outdoor automatically adjusts the frequency range for the device, and only frequency ranges supported by the scanning receiver are used to perform spectrum analyzer measurements. ♦ Based on the start and stop frequency and the number of samples (points), Nemo Outdoor calculates the correct resolution bandwidth (RBW). It should be noted that resolution bandwidths with Nemo FSR1 scanners are fixed. The currently supported values are: 1875, 3750, 7500, 15000, 30000, 60000 and 120000 Hz. Nemo Outdoor automatically selects the closest RBW to be used. 28
  • 29. Nem o F S R1 29 5. You can add scanning sets in the Predefined scanning sets field through the Add to Scanning List button. Click the arrow in the button and select Save as Predefined Set. Define a name in the Enter Frequency Set Name field and click OK. 6. The name appears in the Predefined scanning sets field along with the chosen frequency and/or bandwidth information selected in the Reporting field. 7. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 8. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 9. Click the Start Recording button to start recording the results in an output file.
  • 30. Nem o F S R1 Band Scan With the Nemo FSR1 scanner you can perform band scanning. All specified channels are scanned for the selected band and technology and the strongest measured identifiers (CDMA PN, EVDO PN, WCDMA SC, LTE Cell ID) for every valid channel of that technology type are reported. Signal strength and signal quality are reported for each identified channel. This feature is useful in areas where broadcasted technologies and bands are unknown. 1. To start a band scan, right click the Nemo FSR1 item in the Devices view and select Band Scan. 2. Available technologies and bands supported by the scanner are shown under Scan settings. Please note that only licensed technologies (systems) are shown. 3. Select the technologies and bands that you want to be scanned and define the threshold levels for the parameters available. 4. Finally press the Start Scan button. With the default threshold values it takes approximately two minutes and 30 seconds to scan GSM 900, 1800 and WCDMA 2100 bands. The scanning rate can be increased by adjusting the threshold values. 30
  • 31. Nem o F S R1 5. Scanning results are displayed on the Scan results page. It is possible to save the results to a text file (.csv). 31
  • 32. Nem o F S R1 32 CALIBRATING NEMO FSR1 Self-test runs every time the handler is started and notifications are sent to the user interface depending on the calibration results. Self-test results can be viewed in the Nemo Outdoor Output window. • Test passed • • Calibration warning • • No action required. Indicates that there are no known issues with receiver/down converter module calibration. Measured noise level indicates that the down converter is functioning but may be at or approaching calibration limits. Recommended that the down converter is calibrated as soon as possible. Please contact Nemo helpdesk or local sales representative to arrange re-calibration. Test failure • Measured noise levels are significantly out of range and down converter is not functioning correctly. Recommended that the down converter be returned immediately for factory assessment, potential repair, and calibration. Please contact Nemo helpdesk or local sales representative to arrange service for the unit.
  • 33. A nr its u 33 ANRITSU CONNECTING ANRITSU SCANNERS ♦ These instructions apply to all Anritsu scanners, except Anritsu MS2721B DVB-H Analyzer. 1. Connect the antenna cable to scanner RF Input. If you are measuring with a dual-mode scanner that supports both GSM and WCDMA, use the RF1 input (see picture). RF2 input only supports WCDMA scanning. 2. Connect the battery cable to the battery and to a power source. 3. The Battery led of the scanner should turn green.
  • 34. A nr its u ♦ 34 The following steps apply to Anritsu ML8720B and ML8720C scanners. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see step 12. 4. Connect the null modem cable to the scanner COM port that can be found below the power switch. 5. Connect the null modem to one of the PC COM ports 6. Turn the power on in the scanner. The Power led should light up. 7. The scanner should now start, wait until the scanner has started 8. Press the Menu button in the scanner. 9. Use the arrow keys and the Sel button to select Interface and Behavior. 10. Check that the settings are as follows. If not, change them using the arrow keys and the Sel button (note that the selected item will be underlined as soon as you use the arrow buttons to switch to another line). To exit the dialog without saving, press the F4 button (Cancel). To exit the dialog and save the modified settings, press the F5 button (OK). • COM1 Protocol: Direct • COM1 Baud Rate: 38400 or 57600 or 115200 • COM1 Stop Bit(s): 1 • COM1 Data Length: 8 • COM1 Parity: None ♦ The baud rate 115200 is the fastest option. ♦ Note! Memorize the baud rate. It is needed when starting the device.
  • 35. A nr its u 35 11. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see the following steps. 12. Insert the Anritsu installation CD in your PC. 13. Connect the USB cable to the scanner USB port found in the front panel and to the PC. 14. Switch the scanner on. 15. The New Hardware Wizard will start automatically. Select the No, not this time option and click Next. 16. Select the Install the software automatically option and click Next.
  • 36. A nr its u 36 17. If a warning message appears, click Continue Anyway. The installation will start. Please wait while the New Hardware Wizard installs the software. When the installation is complete, click Finish. 18. To check that the installation was successful, go to Device Manager (Start | Settings | Control Panel | System | Hardware | Device Manager). Expand the Universal Serial Bus controllers item. Area Scanner should be on the list.
  • 37. A nr its u 37 19. Double-click on Area Scanner. Check that the Device Status field displays This device is working properly. Exit the dialog by clicking OK. Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer Scanner 1. To install the device drivers the user must have administrative rights to its PC, and the Take ownership of files or other objects policy has to be enabled for this user on this PC. 2. Copy the executable file visa400full.exe to your local drive before installing the driver, and run the installation from the hard drive. 3. Double-click on the file and unzip the contents to your hard-drive. This may take a couple of minutes. 4. The installation starts automatically. 5. Click Next>> on the welcome page.
  • 38. A nr its u 38 6. Select the destination folder for the driver and click Next>>. 7. Click Next>> in the Features dialog. 8. Select I accept the License Agreement(s) in the following page and click Next>>. 9. Click Next>> in the following dialog and wait for the installation to finish, and Finish in the Installation Complete dialog. Note that you may need to restart your computer for the installation to take effect.
  • 39. A nr its u 39 10. Connect the scanner with your PC through a network cable. Insert one end of the network cable in the network cable connector in the scanner, and the other end to the network cable connector in your PC. 11. Next, you need to make some changes to your PC’s network card properties. Go to Start | Control Panel | Network Connections, and right-click on Local Area Connection, and select Properties. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) and click on Properties. Select Use the following IP address. You need to type in an IP address out of the range 192.168.0.11 - 192.168.0.14, as those addresses are reserved for the scanner. Type in, for example, 192.168.0.10. Next, type 255.255.0.0 in the Subnet mask field. Click OK and Close to exit the dialogs. 12. Next, start the scanner by pressing on the green On/Off button. 13. Press on Shift and then System (8) button on the scanner. 14. On the menu to the right of the screen, select System Options | Ethernet Config by using the grey buttons next to the screen.
  • 40. A nr its u 40 15. Select the Set the IP Address Manually using the following Settings by pressing the topmost grey button immediately under the Esc button. 16. Type in the same IP address for both IP and Gateway from those reserved for the scanner (192.168.0.11 - 192.168.0.14). Here the selected IP address will be 192.168.0.14. You can move to different directions on the screen through the grey buttons. If the Subnet field is not automatically filled when filling the IP and Gateway fields, you can use, for example, 255.255.255.255 for it. Press Enter and restart the device by clicking twice on the On/Off button. 17. When the scanner has restarted, start Nemo Outdoor. Go to Measurement | Add device | Scanner, and select Anritsu MS2721B DVB-H or Anritsu MS2721B Spectrum Analyzer. Click Next. 18. In the Scanner Properties dialog that appears, select one of Anritsu LAN 1-4 ports depending on which IP address you entered on the device. If you entered 192.168.0.11, select Anritsu LAN 1, if you selected 192.168.0.12, select Anritsu LAN 2, etc. Since 192.168.0.14 was selected earlier, the Anritsu LAN 4 port will be used here. ♦ Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so they can be left as they are. 19. Click OK. See page 53 for more information on how to perform DVB-H measurements. See page 53 for instructions regarding settings for the Spectrum Analyzer.
  • 41. A nr its u 41 STARTING ANRITSU SCANNERS 1. Start Nemo Outdoor. Do not load any previous device configuration if asked. 2. From the Measurement menu, select Add New Device. 3. Click on Scanner. 4. From the list select: • For Anritsu ML8720B: Anritsu ML8720B UMTS 2100 and click Next. • For Anritsu ML8720C without the GSM option: Anritsu ML8720C UMTS 2100 and click Next. • For Anritsu ML8720C with the GSM option: Anritsu ML8720C GSM/UMTS and click Next. • For Anritsu ML8740A and Anritsu ML8740B without the GSM option: Anritsu ML8740A/ ML8740B UMTS 2100 and click Next. • For Anritsu ML8740A and Anritsu ML8740B with the GSM option: Anritsu ML8740A/ML8740B GSM/UMTS and click Next. • For Anritsu MS2721B DVB-H Analyzer: Anritsu MS2721B DVB-H, and click Next. • For Anritsu MS2721B Spectrum Analyzer: Anritsu MS2721B Spectrum Analyzer, and click Next. 5. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to (ML8720B/ML8720C)/select the USB port (e.g., Anritsu USB1)/or select the Anritsu LAN 1-4 with Anritsu MS2721B DVB-H depending on which IP address was selected for the scanner. ♦ The next step is not valid for the Anritsu ML8740A, Anritsu ML8740B, Anritsu MS2721B DVB-H, or Anritsu MS2721B Spectrum Analyzer scanner.
  • 42. A nr its u 42 6. Set the baud rate to the one used by the scanner and click OK. Note that the baud rate must be the same that you chose when you were connecting the scanner. The dialog will be closed and the scanner should now be connected to the system. 7. If the dialog did not close, the startup did not succeed. Check the cable connections and the settings and try again. 8. If the Device Status window is not visible, open it from the View menu. A green light should be blinking. This means that the device is working properly and scanning using the default settings. If the status field displays, Device is not started, check that you are in online mode (click the Work Offline/Online button ). MEASURING WITH ANRITSU SCANNERS Frequency Scanning 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog you can select the channels to be scanned: • If the scanner supports only one carrier, you can select either GSM or UMTS channels to be scanned. • If the scanner supports two carriers, you can select for scanning both GSM and UMTS channels. If you select GSM channels, you can select a maximum of one UMTS channel. If you do not select GSM channels, you can select one or two UMTS channels. 3. On the Frequency scanning, GSM page, click the Select Channels button to select the GSM channels to be scanned.
  • 43. A nr its u ♦ 43 Note that the scanner reports the 32 strongest channels from the selected GSM channels. Channel style defines the style of the measured channel. For GSM the options are 200 kHz and 30 kHz narrow. Data mode defines the type of measurement data computed from each sample. Note that the available selection depends on the scanner type. • RX Level Average: the data reported is the average RX level, in dB, of the number of samples. • RX Level Maximum: the data reported is the maximum RX level, in dB, of the number of samples. • RX Level Minimum: the data reported is the minimum RX level, in dB, of the number of samples. • RX Level Standard Deviation: the data reported is the standard of deviation of the number of samples reported as an integer. • RX Level 10%: the data reported is the 10th percentile RX level, in dB, of the number of samples. • RX Level 50%: the data reported is the 50th percentile RX level, in dB, of the number of samples.
  • 44. A nr its u 44 • RX Level 90%: the data reported is the 90th percentile RX level, in dB, of the Number of samples. Measurement period defines the time in milliseconds for which the scanner measures and then reports the result. Sample size defines the number of samples taken from each channel before a measurement result is written to file. Selecting the BSIC decoding option displays BSIC value in a measurement window. BSIC Threshold defines the minimum BSIC level that the scanner reports. BCCH C/I option is available with PCTEL and Rohde&Schwarz GSM scanners only. 4. Click the Start Recording button to start recording the results in an output file.
  • 45. A nr its u 45 TOP-N Pilot Scanning - UMTS Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode/Scanning. ∇ To set pilot scanning settings: 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page. ♦ Note that some of the options are enabled/disabled in this dialog according to the selected scanner model. Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow Band (200kHz) and Wide Band (3.84MHz). For Anritsu scanners, only Wide Band is available. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Measurement period defines the time in milliseconds for which the scanner measures and then reports the result.
  • 46. A nr its u 46 Number of fingers defines the maximum number of fingers used for RAKE in measurement. Selective level determines a valid path. Set a value (in dB) to decide a valid path from the noise floor (average value). Rake threshold determines a valid path (in dB). Subtracting the set value from a path with a maximum correlation value gives the lower limit of the valid path. Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode. Delay profile option enables/disables delay profile scanning. The Channel number field provides a list of channels that can be selected for scanning. Finger option enables and disables Finger measurements for the scanner. P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling code. SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for each scrambling code. S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling code. The Top-N Configuration button will open the Select Channels dialog where you can select channels for pilot scanning. If you press the arrow, a drop-down menu will appear from where you can select Top-N Search Configuration. ♦ Please note that the Top-N Search Configuration dialog is available for Anritsu UMTS scanners only.
  • 47. A nr its u 47 In the Top-N Search Configuration dialog you can limit the search performed by the scanner and consequently speed up the search. Group specifies the group number for the primary scrambling code in the range of 0 to 63. Cell specifies the cell number for the primary scrambling code in the range of 0 to 7. Secondary code specifies the secondary scrambling code. Limit range should be set from 0 to 0. Channelization code specifies the channelization code. Limit range should be set from 0 to 0. Search method defines how the search is performed. P-CPICH (primary common pilot channel) searches with P-CPICH. SCH performs a three-step search with P-SCH and S-SCH. ∇ To select pilot parameters: 1. Select the TOP-N Mode option. 2. Set the Number of Scrambling codes value. This defines how many strongest pilots are to be reported by the scanner. The maximum is 32 pilots.
  • 48. A nr its u ∇ 48 To select channels: 1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N Configuration button. The Select Channels dialog is opened. 2. The table displays the channel numbers, not the frequencies. ♦ With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be selected. 3. You can remove channels from the Selected list by selecting a channel and clicking the Remove button. 4. You can add channels to the Selected list by selecting a channel from the Available list and clicking the Add button. 5. Click OK to return to the Measurement Properties dialog.
  • 49. A nr its u ∇ 49 To select search parameters: 1. Open the Measurement Properties, Pilot scanning, UMTS page. Press down the Top-N Configuration button and select Top-N Search Configuration. 2. The Top-N Search Configuration dialog opens.
  • 50. A nr its u 50 3. Set the Group search range. The group number is the scrambling code divided by 8. For example, SC (scrambling code) 12 = group 1, cell 4. 4. Set the Cell search range. The cell number is the division modulus. For example, SC (scrambling code) 12 = group 1, cell 4. 5. The Secondary Code and the Channelization Code ranges should be set from 0 to 0 for scanning only the P-CPICH. 6. Select the Search Method. SCH means that the P-CPICH are searched using P-SCH and S-SCH. P-CPICH means that the P-CPICH are searched without using P-SCH and S-SCH. ♦ Note that the P-CPICH method is much slower than the SCH method. 7. Click OK to accept the settings and to return to the Measurement Properties dialog. 8. Data processing method defines how the scanner will process samples before reporting. 9. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data processing method is used. ♦ In pilot scanning mode, the RSSI is always measured for each channel. ♦ In pilot scanning mode the P-CPICH Ec/N0 and RSCP are always measured for each scrambling code. 10. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 11. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 12. Click the Start Recording button to start recording the results in an output file.
  • 51. A nr its u 51 Pilot Scrambling Code Scanning Pilot Scrambling Code Scanning or Known Scrambling Code Scanning can be used to scan known pilots. The Known Scrambling Code Scanning will from now on be referred to as Normal Pilot Mode. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 1. Go to the Measurement Properties, Pilot scanning, UMTS page . 2. Clear the TOP-N mode option and click the Select Channels button. The Select Scrambling Codes dialog is opened. 3. Select channels in the Selected channel numbers table by clicking the Select button. ♦ With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be selected. 4. For each selected channel, select scrambling codes. Select a channel and click the Select button below the Selected scrambling codes table. 5. Click OK to return to the Measurement Properties dialog.
  • 52. A nr its u 52 6. When using an Anritsu scanner in Pilot Scanning mode, you can define the measurement period. It defines the time period from which results are gathered and processed before reporting. 7. Data processing method defines how the scanner will process samples before reporting. ♦ In Pilot Scanning Mode the RSSI is always measured for each channel. ♦ In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each scrambling code. 8. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 9. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 10. Click the Start Recording button to start recording the results in an output file.
  • 53. A nr its u 53 DVB-H Scanning DVB-H scanning can be performed with the Anritsu MS2721B DVB-H Analyzer scanner. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 11. In the Measurement Properties, Pilot scanning, DVB-H page, select a frequency to be measured. Anritsu MS2721B DVB-H Analyzer scans frequencies between (DVB-H) 474 850 MHz. 12. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 13. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 14. Click the Start Recording button to start recording the results in an output file.
  • 54. A nr its u 54 Spectrum Analyzer Measurements Spectrum scanning can be performed with the Anritsu MS2721B Spectrum Analyzer scanner. 1. Open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Spectrum scanning page.
  • 55. A nr its u 55 3. Select the Enable spectrum scanning option and click on Add. 4. Define the start and stop frequencies within which the measurement will be performed. If you manually define the start and stop frequencies, you can either select to add the frequencies to the scanning list or save them as a predefined set. Select your option in the Add to scanning list menu. 5. Select Set center frequency and bandwidth to define the center frequency and the bandwidth to be measured. If you manually define the center frequency and bandwidth, you can either select to add them to the scanning list, or save them as a predefined set. Select your option in the Add to scanning list menu. ♦ With Anritsu MS2721B spectrum analyzer the supported frequency range is from 9 kHz to 7.1GHz. The sample count is fixed to 551, and RBW is adjusted automatically. RBW is between 1 Hz - 3 MHz. It is automatically adjusted to the closest value of 1 Hz, 3 Hz, 10 Hz, 30Hz, 100 Hz ... 300 kHz, 1 MHz, 3 MHz. 15. When signal volume is lower than -50dBm, selecting the Use preamplifier functionality in the Measurement Properties dialog can increase the scanner’s measuring sensitivity, hence slightly decreasing background noise. However, it is recommended that it is not selected when signal volume is higher than -50dBm.
  • 56. A nr its u 56 16. You can add scanning sets in the Predefined scanning sets field through the Add to Scanning List button. Click the arrow in the button and select Save as Predefined Set. Define a name in the Enter Frequency Set Name field and click OK. 17. The name appears in the Predefined scanning sets field along with the chosen frequency and/or bandwidth information selected in the Reporting field. 18. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 19. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 20. Click the Start Recording button to start recording the results in an output file.
  • 57. DRT 57 DRT CONNECTING THE DRT WIMAX 4301A+ SCANNER ♦ Note! The DRT 4301A+ scanner does NOT have an On/OFF switch. The unit is powered by connecting the power cable and powered off by disconnecting the power cable. When connecting cables to the unit, the power cable should be the last one connected and the first one disconnected. 1. Insert one end of the RJ-45 cable in the DATA jack in the scanner, and connect the other end with the PC. 2. Insert the power cable in the connector marked DC IN. 3. Plug the antenna cable in the FR IN B port in your DRT scanner. ♦ Note that you can only select one of the antennas, 2300/2500MHz or the 3500MHz antenna, and connect it with the scanner. You must select between the antennas at this point. 4. Connect the scanner’s GPS antenna cable to the scanner’s GPS port, and place the GPS antenna on a visible spot. 5. Go to Start | Control Panel | Network Connections on your PC. 6. Right-click on Local Area Connection and select Properties. 7. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) | Properties.
  • 58. DRT 58 8. In the General tab, select Use the following IP address, and type 192.168.5.1 in the IP address field, and 255.255.255.0 in the Subnet mask field. 9. Click OK and Close to exit the dialogs. 10. Now connect the scanner’s power cable. The scanner is now on. A green light will turn on in the scanner. 11. Start Nemo Outdoor. Go to Measurement | Add New Device | Scanner. Select DRT WIMAX 2300, DRT WIMAX 2500 or DRT WIMAX 3500 depending on which band you choose to measure at the time.
  • 59. DRT 59 12. In the Scanner Properties dialog, select DRT LAN in the Port drop-down menu. ♦ Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so they can be left as they are. 13. Click OK to exit the dialog. 14. Go to page 62 for more information on conducting WIMAX measurements with the DRT scanner.
  • 60. DRT 60 STARTING DRT SCANNERS 1. Start Nemo Outdoor. Do not load any previous device configuration if asked. 2. From the Measurement menu, select Add New Device. 3. Click on Scanner. 4. From the list select: • DRT WIMAX 2300, if you want to make measurements with the 2300 MHz (WiMAX) band. • DRT WIMAX 2500, if you want to make measurements with the 2500MHz (WiMAX) band. • DRT WIMAX 3500, if you want to make measurements with the 3500MHz (WiMAX) band.
  • 61. DRT 61 5. In the Scanner Properties dialog, set the COM Port to DRT LAN. ♦ Note that the no changes need to be made to the Baud rate, Antenna gain, and Cable loss fields. See the next chapter for further instructions on how to make measurements.
  • 62. DRT 62 MEASURING WITH DRT SCANNERS Frequency Scanning Frequency scanning can be used to scan band power. It is also useful for checking that the band is deselected and for finding out the center frequency. 1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. You can enable or disable the integrated GPS receiver through the Advanced button. It is also possible to use an external GPS device with the scanner. 3. In the Measurement Properties dialog, go to the Frequency scanning page. 4. In the Channel Style list box, select the channel width. The options are Wide Band (5000 kHz) and Wide Band 2 (10000 kHz).
  • 63. DRT 63 5. Click the Select Frequencies button to open the Select Frequencies dialog. 6. The table displays the available frequencies. Select and add them in the Selected view by clicking on Add>>. 7. Remove frequencies from the Selected list by selecting a frequency and clicking the Remove button. 8. Add frequencies in the Selected list by selecting a frequency from the Available list and clicking the Add button. 9. Click OK to return to the Measurement Properties dialog. 10. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 11. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 12. Click the Start Recording button to start recording the results in an output file.
  • 64. DRT 64 Pilot Scanning 1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page. Channel style refers to the style of the channel. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. Top-N option enables/disables TOP-N scrambling code scanning. If enabled, scanner will report results from N best preambles. Number of preambles field defines how many preambles are reported by the scanner in TOP-N mode. CINR refers to the Carrier to Interference and Noise ratio value, in dB *100 (e.g., -16.34). It is based on the requested reuse factor. Preamble delay refers to the number of samples between expected arrival time and actual arrival time of preamble with respect to GPS time reference. The values range from 0 to 1023+32. Each sample corresponds to 89.285 nanoseconds.
  • 65. DRT 65 Reuse factor refers to a system design parameter that can be manipulated to achieve the desired balance between the interference and the network coverage. The WiMAX air interface modulating waveform has been divided into three segments (Segment 0, 1 and 2). The allocation of frequency sub-carrier into these three segments is done in such a way that e.g. a downlink signal on segment 0 will not interfere with the downlink signal on segment 1. In a Reuse Factor 1 measurement, contributions from all the three segments are considered in the measured parameters, so that the CINRs are calculated from all the three segments. When Reuse Factor 3 is selected, only the contribution of the desired segment is considered, and the CINRs are calculated only from the same segment. As a broad guideline, measurements performed with Reuse Factor 1 will provide the signal quality of the all the detected preambles relative to each other, whereas the Reuse Factor 3 category of measurements will provide the signal quality of preambles within the same segment. Delay spread defines if the selected scanner will also measure the delay spread value (in chips) for each scanned scrambling code. Delay spread is determined as the difference between the last and first component to break the threshold set in PN Threshold. 3. The Top-N Configuration button will open the Select Frequencies dialog where you can select frequencies for scanning. The maximum number of frequencies that can be selected is device specific.
  • 66. DRT 66 4. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 5. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. In TOP-N Mode this may take a few seconds. 6. Click the Start Recording button to start recording the results in an output file.
  • 67. PCT EL 67 PCTEL CONNECTING PCTEL LX CDMA/EVDO/GSM/WCDMA SCANNER 1. Connect the antenna cable to the scanner RF Input. 2. Connect the scanner GPS antenna cable to the scanner GPS input (above RF Input).
  • 68. PCT EL 68 3. Connect the scanner power cable to the scanner serial port (Data). 4. The scanner cable is split into a serial cable connector and a power cable connector. Connect the serial cable to one of the COM ports in the PC. Connect the scanner power cable to a cigarette lighter in the car. 5. When connecting the scanner power cable, check the Power led: • • ∇ ♦ If the led blinks orange and black for a while and then turns green, the scanner is working properly and using baud rate of 115200 • ♦ If the led is first orange for a while and then turns green, the scanner is working properly and using a baud rate of 38400 If the led is red, the scanner is not working properly. Switch the power off and on again. If this occurs after usage, the device may be overheated. Let it cool down for a while. Note! Memorize the baud rate. It is needed when starting the device. Connecting an external GPS to PCTEL LX EVDO/GSM/WCDMA scanner Note that you cannot use both the integrated and an external GPS receiver at the same time. 1. Connect the GPS serial cable to a PC serial port. ♦ If there is only one port in the PC by default, this port should be reserved for the scanner. In this case connect the GPS to the PCMCIA serial port adapter. 2. Connect the GPS power cable to a cigarette lighter.
  • 69. PCT EL 69 CONNECTING PCTEL EX SCANNERS 1. To install the device drivers the user must have administrative rights to its PC, and the Take ownership of files or other objects policy has to be enabled for this user on this PC. 2. Copy the folder /SeeGull EX VCP driver_v.2.0.0.46B to your local drive before installing the driver, and run the installation from the hard drive. • Right click on the folder and select Properties. • Clear the Read-only attributes and click OK. • Select Apply changes to this folder, subfolder and files as below and click OK. 3. Double-click on the SeeGull EX VCP Device Driver.msi installer file to start the driver installation. 4. Click Next in the SeeGull Welcome window that appears. 5. Select the destination folder for the driver in the Destination Folder window, and Click Next, and click Install. 6. Click Finish in the InstallationShield Wizard Completed window to exit the wizard.
  • 70. PCT EL 70 7. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front panel. 8. Connect the power cable to the Power connector in the front panel. Connect the other end of the cable to a cigarette lighter socket. The SYS indicator in the front panel will light up.
  • 71. PCT EL 71 9. Connect the antenna cables. It does not matter which antenna cable goes to which RF connector. 10. Connect the GPS antenna to the connector marked GPS.
  • 72. PCT EL 72 11. Connect the USB data cable to the USB port in the front panel. Connect the other end of the USB data cable to your PC. 12. Windows will automatically detect the device.
  • 73. PCT EL 73 CONNECTING THE PCTEL LX GSM/WCDMA DUAL-MODE SCANNER 1. Remove the yellow plastic caps from the antenna and GPS connectors in the front panel. 2. Connect the power cable to the Power and Data connector in the front panel. Connect the other end to a USB port on your computer and to a power source. The green Power indicator in the scanner front panel will light up.
  • 74. PCT EL 74 3. Connect the antenna cables. Note that the antenna cables and the connectors in the scanner front panel are color coded. The OP042 cable marked with yellow is connected to the RF1 connector marked with yellow (connector on the left). The OP039 cable marked with blue is connected to the RF2 connector marked with purple (connector in the middle). 4. Connect the GPS antenna to the connector marked GPS (connector on the right). 5. Windows will have detected the new device and will install the required drivers. Insert the PCTEL installation CD. 6. Select No, not this time in the Welcome dialog.
  • 75. PCT EL 75 7. Select Install from a list of specific location and click Next. 8. Select Include this option in the search and browse to folder D:EdgeportUSBEdgeport Vendor Datadriver vx.x. Click Next to start the installation. 9. When the installation is finished, click Finish. Windows will automatically install some additional drivers and report when the device is ready to be used.
  • 76. PCT EL 76 CONNECTING THE PCTEL MX SCANNER 1. To install the device drivers the user must have administrative rights to its PC, and the Take ownership of files or other objects policy has to be enabled for this user on this PC. 2. Browse to folder seegull mx driverMX winusb driver. For 32-bit operating system run DPInst.exe from “install x86” folder and for 64-bit operating system run DPInst.exe from “install x64” folder. 3. The PCTEL USB Device Installer window will appear. Click Next. 4. If a Windows Security message appears, click Install. 5. Click Finish in the installation completed window. 6. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front panel. 7. Connect the power cable to the PWR connector in the front panel. Connect the other end of the cable to a cigarette lighter socket. Turn the switch to On position. The Status indicator in the front panel will light up.
  • 77. PCT EL 77 8. Connect the antenna cables. The label on the scanner lists the frequencies of the radio modules connected to each specific port, labeled RF1 to RF4. The antenna ports that require antenna connections are identified by their “frequency” on the label. Since each SeeGull MX is configured to minimize the number of ports necessary for use, some ports may be inactive for a particular configuration and are indicated by a blank box. 9. Connect the GPS antenna to the connector marked GPS. 10. Connect the USB data cable to the USB port in the front panel. Connect the other end of the USB data cable to your PC.
  • 78. PCT EL 78 11. Windows Vista and Windows 7 will automatically detect and install the device. 12. With Windows XP a Found new Hardware window will appear. Select No, not this time in the Welcome window. Select Install the software automatically (Recommended) and click Next. Finally click Finish. 13. Go to Device Manager and select PCTEL Devices. Memorize the port number for the PCTEL MX Scanner item, as you will need it later on.
  • 79. PCT EL 79 CONNECTING PCTEL PCT SCANNERS 1. Run the PL2303_Prolific_DriverInstaller_vx.x.exe (x refers to the version number) file on the installation CD to install device drivers. 2. Click Next in the Welcome window that appears. 3. Click Finish to finish the driver installation. 4. Next, remove the yellow plastic caps from the antenna and GPS connectors in the front panel of the PCTEL PCT scanner. 5. Connect the antenna cable in the RF Input connector.
  • 80. PCT EL 80 6. Connect the data cable to the Data connector. Connect the other end of the USB data cable to your PC. 7. Connect the power cable to the Power connector in the front panel. Connect the other end of the cable to a cigarette lighter socket. 8. Windows automatically detects the new hardware.
  • 81. PCT EL 81 9. Go to Start | Control Panel | System | Hardware | Device Manager and select Ports. Memorize the port number for the Prolific USB-to-Serial Comm Port item, as you will need it later on.
  • 82. PCT EL 82 CONNECTING PCTEL SCANNERS TO NEMO INVEX CHASSIS PCTEL scanners are connected to the Nemo Invex chassis (UIC module) with a USB cable. If your PCTEL scanner has a serial cable, you will need a USB serial adapter. The USB cable is connected to the USB-1 or USB-2 port on the UIC module. PCTEL scanners can be attached on top of the Nemo Invex chassis with a mounting plate.
  • 83. PCT EL 83 STARTING PCTEL SCANNERS ∇ Starting the GPS: With the PCTEL LX WCDMA scanner you can use either the GSP receiver integrated into the scanner or an external GPS. See page 86 for instructions on how to enable the integrated GPS receiver. ♦ Note that you cannot use both the integrated and an external GPS receiver at the same time. ♦ Note that with the PCTEL LX GSM/WCDMA scanner the Internal GPS receiver should be activated only in UMTS mode. ♦ To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix at least 30 seconds before starting the Nemo Outdoor application in online mode. If the existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the configuration file in offline mode. If scanner does not send any results after 30 seconds, it is advised to send a reset command to the scanner via the user interface. 1. From the Measurement menu, select Add New Device. 2. Click on GPS. 3. From the list, select the GPS model that you have connected to the PC and click Next. 4. The GPS Properties dialog is opened. Set the parameters (see the GPS User Manual for instructions). They should be correct by default. Click OK. The view will return to the Nemo Outdoor main window. 5. In the Device Status window a green light should be blinking. This means that the GPS is working properly. ∇ Starting the PCTEL MX/LX/EX/PCT GSM/WCDMA/1xEVDO/LTE Scanner: 1. Start Nemo Outdoor. Do not load any previous device configuration if asked. 2. From the Measurement menu, select Add New Device. 3. Click on Scanner. 4. From the list of scanners, select the appropriate handler according to the following table, and click Next. Scanner Handler PCTEL LX GSM 1800 PCTEL LX GSM 1800 PCTEL LX GSM 1900 PCTEL LX GSM 1900 PCTEL LX GSM 850 PCTEL LX GSM 850 PCTEL LX GSM 850/1900 PCTEL LX GSM 850/1900 PCTEL LX GSM 900 PCTEL LX GSM 900 PCTEL LX GSM 900/1800 PCTEL LX GSM 900/1800 PCTEL LX UMTS 1700/2100 PCTEL LX UMTS 1700/2100
  • 84. PCT EL 84 PCTEL LX UMTS 1900 PCTEL LX UMTS 1900 PCTEL LX UMTS 2100 PCTEL LX UMTS 2100 PCTEL LX UMTS 850/1900 PCTEL LX UMTS 850/1900 PCTEL LX UMTS 850 PCTEL LX UMTS 850 PCTEL LX CDMA/EVDO 850 PCTEL LX EVDO 800 PCTEL LX 1xEVDO 450 PCTEL LX EVDO 450 PCTEL LX 1xEVDO 850 PCTEL LX EVDO 800 PCTEL LX 1xEVDO 1900 PCTEL LX EDVO 1900 PCTEL LX 1xEVDO 800/1900 PCTEL LX EDVO 800/1900 PCTEL EX CDMA/EVDO 850/1900 PCTEL EX CDMA2000 850/1900 EVDO 850/1900 PCTEL EX GSM 850/1900 & WCDMA 850/1900 PCTEL EX GSM 850/1900 UMTS 850/1900 PCTEL EX GSM 900/1800 & WCDMA 900/2100 PCTEL EX GSM 900/1800 UMTS 900/2100 PCTEL EX GSM 900/1800 & WCDMA 2100 PCTEL EX GSM 900/1800 UMTS 2100 PCTEL EX GSM 1900 & WCDMA 2100 AWS PCTEL EX GSM 1900 UMTS AWS PCTEL EX WIMAX PCTEL EX WIMAX PCTEL EX 900/1800 WCDMA/TD-SCDMA 2000 PCTEL EX 900/1800 UMTS TDSCDMA 2000 PCTEL EX WCDMA 2100 AWS&GSM 850/ 1900 PCTEL EX GSM 850/1900 UMTS AWS PCTEL EX LTE 700ABC PCTEL EX LTE 700ABC PCTEL EX LTE 700ABC/Upper 700C/AWS PCTEL EX LTE 700ABC/Upper 700C/AWS PCTEL EX LTE 700C PCTEL EX LTE 700C PCTEL EX LTE AWS/700BC PCTEL EX LTE AWS/700BC PCTEL EX LTE AWS/700C PCTEL EX LTE AWS/700C PCTEL EX LTE 800 PCTEL EX LTE 800 PCTEL EX LTE 800/2600 PCTEL EX LTE 800/2600 PCTEL EX LTE 1600 PCTEL EX LTE 1600 PCTEL EX LTE 1800/2600 PCTEL EX LTE 1800/2600 PCTEL EX LTE 2100 PCTEL EX LTE 2100 PCTEL EX LTE 2100/2600 PCTEL EX LTE 2100/2600 PCTEL EX LTE 2600 PCTEL EX LTE 2600 PCTEL EX LTE AWS PCTEL EX LTE AWS
  • 85. PCT EL 85 PCTEL EX Mini series scanners: • WCDMA 2100 PCTEL EX UMTS 2100 • WCDMA 850/1900 PCTEL EX UMTS 850/1900 • WCDMA 900/2100 PCTEL EX UMTS 900/2100 • WCDMA AWS PCTEL EX UMTS AWS PCTEL MX PCTEL MX PCTEL PCT GSM 900/1800 PCTEL PCT GSM 900/1800 PCTEL PCT UMTS 2100 PCTEL PCT UMTS 2100 5. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to. With MX scanners, select the PCTEL USB item. 6. Set the baud rate to the one used by the scanner and click OK. The dialog will be closed and the scanner should now be connected to the system. 7. If the dialog did not close, the start-up did not succeed. Check the cable connections and the settings and try again. 8. From the View menu activate Device Status. A check mark will appear next to the command when it is activated. 9. A green light on the PCTEL scanner in the Device Status window should be blinking. This means that the device is working properly and scanning using the default settings. See chapter Starting Measurement (page 125) for instructions on making your own scanner configuration.
  • 86. PCT EL ∇ 86 Enabling integrated GPS receiver for PCTEL LX WCDMA/PCTEL EX WiMAX scanner 1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog click the Advanced button. 3. In the Advanced Properties dialog, select Yes for the Enable Integrated GPS Receiver option and click OK. 4. The integrated GPS receiver is now enabled. ♦ Note that you cannot use both the integrated and an external GPS receiver at the same time. ♦ Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be activated only with UMTS mode. ♦ To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix at least 30 seconds before starting the Nemo Outdoor application in online mode. If the existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the configuration file in offline mode. If scanner does not send any results after 30 seconds, it is advised to send a reset command to the scanner via the user interface.
  • 87. PCT EL ∇ 87 Starting the PCTEL LX GSM/WCDMA dual-mode scanner 1. Start Nemo Outdoor. Do not load any previous device configuration if asked. 2. From the Measurement menu, select Add New Device. 3. Click on Scanner. 4. From the list select PCTEL LX GSM 900/1800 and click Next. 5. In the Scanner Properties dialog, Port field you should see two consecutive COM ports (e.g., COM 3 and COM 4). Select the COM port with the smaller number and click OK. 6. From the Measurement menu, select Add New Device. Click on Scanner. 7. From the list select PCTEL LX UMTS 2100 and click Next. 8. In the Scanner Properties dialog, Port field you should see two consecutive COM ports (e.g., COM 3 and COM 4). Select the COM port with the bigger number and click OK. 9. A green light should be blinking in the Device Status for both devices. This means that the devices are working properly and scanning using the default settings. If the status field displays, Device is not started, check that you are in online mode (click the Work ). Offline/Online button 10. The GSM and UMTS scanners will appear as separate devices and must be configured individually.
  • 88. PCT EL ∇ ♦ 88 Enabling integrated GPS receiver for PCTEL LX GSM/WCDMA dual-mode scanner Note that with the PCTEL dual-mode scanner the integrated GPS receiver needs to be enabled only for one scanner. 1. After the PCTEL LX scanners are connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog click the Advanced button. 3. In the Advanced Properties dialog, select Yes in the Enable Integrated GPS Receiver option and click OK. 4. The integrated GPS receiver is now enabled. ♦ Note that you cannot use both the integrated and an external GPS receiver at the same time. ♦ Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be activated only with UMTS mode.
  • 89. PCT EL 89 MEASURING WITH PCTEL SCANNERS Frequency Scanning – PCTEL GSM/UMTS Scanners Frequency scanning can be used to scan band power. It is also useful for checking that the band is deselected and for finding out the center frequency. 1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Frequency scanning, UMTS page. 3. In the Channel style field, select the channel width. The options are narrow band (200 kHz) and wide band (3.84 MHz). ♦ To find out the center frequency used, set the Channel Style to 200 kHz and select all the channels in the frequency region where the carrier should exist; for example, all channels allocated to an operator. The center frequency will stand out in Frequency Scanning mode. The received signal should be above the noise level in order to find out the center frequency.
  • 90. PCT EL 90 4. Click the Select Channels button to open the Select Channels dialog. 5. The table displays the channel numbers, not the frequencies. 6. Remove channels from the Selected list by selecting a channel and clicking the Remove button. 7. Add channels to the Selected list by selecting a channel from the Available list and clicking the Add button. 8. Click OK to return to the Measurement Properties dialog. 9. Click OK and OK to close the Measurement Properties dialog and to re-start the scanner with the new settings. 10. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 11. Click the Start Recording button to start recording the results in an output file.
  • 91. PCT EL 91 Frequency Scanning – PCTEL EX LTE Scanner 1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. By clicking the Advanced button on the General page, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 2. On the Frequency scanning page, define the Channel style.
  • 92. PCT EL 92 3. By clicking the Select Channels button, you can access the Select Channels dialog. 4. Select one band from the list or all of them. You can also select one band at a time and add the bands you want to scan. If all bands are selected, you have the possibility to select Remove All | ... items from every band. Alternatively, if only one band is selected you can remove only items from the current band through Remove All | ...items from current band. The Available view provides a list of channels that are available for scanning. To add channels to the Selected list, click on a number in the Available list and then click the Add button or simply double-click a channel to add it to the Selected list. To select all available channels for scanning, click the Add All button. An alternative method to select channels is to type the channel numbers in the field at the bottom of the dialog and to click Add. To remove channels from the Selected list, click on the channel you want to remove and then click the Remove button or double-click the channel. To remove all channels, click the Remove All button. You can select several channels simultaneously by holding down the SHIFT key and clicking on the channels you want to add or remove. 5. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 6. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 7. Click the Start Recording button to start recording the results in an output file.
  • 93. PCT EL 93 Frequency Scanning – PCT GSM Scanner 1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 3. Go to the Frequency scanning page. Channel style refers to the style of the channel. Selecting the BSIC decoding option displays BSIC value in a measurement window. BSIC threshold defines the minimum BSIC level that the scanner reports. Select the BCCH C/I option to activate C/I measurements for the BCCH channel. This option is available with PCTEL GSM scanners only.
  • 94. PCT EL 94 4. By clicking the Select Channels button, you can access the Select Channels dialog. 5. Select one band from the list or all of them. You can also select one band at a time and add the bands you want to scan. If all bands are selected, you have the possibility to select Remove All | ... items from every band. Alternatively, if only one band is selected you can remove only items from the current band through Remove All | ...items from current band. The Available view provides a list of channels that are available for scanning. To add channels to the Selected list, click on a number in the Available list and then click the Add button or simply double-click a channel to add it to the Selected list. To select all available channels for scanning, click the Add All button. An alternative method to select channels is to type the channel numbers in the field at the bottom of the dialog and to click Add. To remove channels from the Selected list, click on the channel you want to remove and then click the Remove button or double-click the channel. To remove all channels, click the Remove All button. You can select several channels simultaneously by holding down the SHIFT key and clicking on the channels you want to add or remove. ♦ Note that Sample size and Data mode are not enabled with PCT GSM frequency scanning
  • 95. PCT EL 95 6. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 7. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 8. Click the Start Recording button to start recording the results in an output file. Frequency Scanning – PCTEL CDMA/EVDO Scanners 1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 3. Go to the Frequency scanning page. Channel style refers to the style of the channel. For EVDO scanners, the options are 1250 kHz Normal and 30 kHz Normal. Sample size defines the number of samples taken from each channel before a measurement result is written to file.
  • 96. PCT EL 96 4. By clicking the Select Channels button, you can access the Select Channels dialog. 5. Select one band from the list or all of them. You can also select one band at a time and add the bands you want to scan. If all bands are selected, you have the possibility to select Remove All | ... items from every band. Alternatively, if only one band is selected you can remove only items from the current band through Remove All | ...items from current band. The Available view provides a list of channels that are available for scanning. To add channels to the Selected list, click on a number in the Available list and then click the Add button or simply double-click a channel to add it to the Selected list. To select all available channels for scanning, click the Add All button. An alternative method to select channels is to type the channel numbers in the field at the bottom of the dialog and to click Add. To remove channels from the Selected list, click on the channel you want to remove and then click the Remove button or double-click the channel. To remove all channels, click the Remove All button. You can select several channels simultaneously by holding down the SHIFT key and clicking on the channels you want to add or remove. 6. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 7. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 8. Click the Start Recording button to start recording the results in an output file.
  • 97. PCT EL 97 TOP-N Pilot Scanning - UMTS Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode. 1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. Go to the Pilot scanning page. CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are below the threshold, the pilots are not reported. Channel style refers to the style of the channel. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Pilot measurement mode defines the measurement mode for pilot scanning. • In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode, weak pilots may be undetected. • In High dynamic mode scanning speed is lower but sensitivity is higher.
  • 98. PCT EL 98 Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode. Time of arrival defines if the selected scanner will measure the time of arrival for each scrambling code. The time of arrival value is relative to GPS time and is measured in chips. Delay spread defines if the selected scanner will also measure the delay spread value (in chips) for each scanned scrambling code. Delay spread is determined as the difference between the last and first component to break the threshold set in PN Threshold. P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling code. SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for each scrambling code. S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling code. ∇ To select channels: 1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N Configuration button. The Select Channels dialog is opened. ♦ The table displays the channel numbers, not the frequencies. If you know the frequency but not the channel number, the channel number can be calculated by multiplying the frequency in MHz by five. The channel spacing is always 200 kHz. 2. Remove channels from the Selected list by selecting a channel and clicking the Remove button. 3. Add channels to the Selected list by selecting a channel from the Available list and clicking the Add button. ♦ With a PCTEL LX scanner a maximum of 8 channels can be selected in the pilot mode. ♦ With a PCTEL EX scanner a maximum of 15 channels can be selected in the pilot mode. ♦ With a PCTEL MX scanner 1 channel can be selected in the pilot mode. ♦ With a PCTEL LTE EX scanner a maximum of 15 channels can be selected in the pilot mode. ♦ With a PCTEL PCT scanner a maximum of 4 channels can be selected in the pilot mode. 4. Click OK to return to the Measurement Properties dialog. ∇ To select pilot parameters: 1. Select the TOP-N Mode option. 2. Set the Number of scrambling codes value. This defines how many strongest pilots are to be reported by the scanner. The maximum is 32 pilots. ♦ Note that with the PCTEL PCT Scanner the maximum number of pilots to be selected for scanning is 8.
  • 99. PCT EL ♦ 99 Note that the PCTEL EX WCDMA scanner only supports the TOP-N mode. You can select up to 32 pilots for scanning. 3. To improve on the accuracy of radio propagation models, High speed mode makes it possible to acquire more samples (max 32 pilots per channel), while High dynamic mode offers fewer samples (max 16 pilots per channel) with a larger dynamic range. ∇ To set general parameters: 1. Data processing method defines how the scanner will process samples before reporting. 2. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data processing method is used. ∇ To select measured values: ♦ In Pilot Scanning Mode the RSSI is always measured for each channel. ♦ In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each scrambling code. 1. In the Measurement Properties, Pilot scanning page: • • • • • • Select the P-SCH option to enable P-SCH Ec/N0 and RSCP measurement. Select the S-SCH option to enable S-SCH Ec/N0 and RSCP measurement. Select the Time of arrival option to enable time of arrival measurement. Select the Delay spread option to enable P-CPICH delay spread measurement. Select the SIR option to enable P-CPICH SIR measurement. Select the Delay profile option to enable P-CPICH Delay Profile measurement. In TOPN pilot scanning mode the scrambling code for delay profile measurement cannot be selected. 2. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 3. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 4. Click the Start Recording button to start recording the results in an output file. TOP-N Pilot Scanning – CDMA/EVDO Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode. 1. After the PCTEL LX/EX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data.
  • 100. PCT EL 10 0 3. In the Measurement Properties dialog, go to Pilot scanning page. Channel style refers to the style of the channel. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA. Pilot window mode defines the position of the chips that are searched for pilot across in regard to the ideal pilot position (0 chip delay for a given pilot). Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1, 1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every th th second sample is logged, with ratio 1:4 every 4 sample is logged, and with ratio 1:8 every 8 sample is logged. By decreasing the sampling ratio you can decrease the output file size, but the scanning accuracy will be diminished. Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the threshold, the pilots are not scanned. Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best scrambling codes. Number of pilots field defines how many pilots are reported by scanner in Top-N mode.
  • 101. PCT EL 10 1 Delay option enables/disables delay profile scanning. Delay is defined as the measured difference between the expected arrival time (GPS time) and the actual arrival time of the maximum peak above the PN threshold. It is reported in chips. 4. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 5. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 6. Click the Start Recording button to start recording the results in an output file. Spectrum Scanning ♦ Spectrum scanning is enabled on PCTEL EX scanners only in online mode. Hence, the device needs to be added to Nemo Outdoor in online mode to activate the Spectrum scanning functionality 1. After the PCTEL EX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Spectrum scanning page.
  • 102. PCT EL 10 2 3. Select the Enable spectrum scanning option, and click Add. 4. To create new scanning sets, define the scanning frequencies in the Reporting view. Set start and stop frequencies defines the frequency range that will be scanned. Set center frequency and bandwidth defines the frequency range that will be scanned. The Sample count field determines the sample count measured for the given frequency range. 5. The Add to Scanning List menu enables you to decide whether the new scanning set is added to the scanning list, or saved as a predefined set also for later use. 6. The Predefined scanning sets can be used to quickly select the frequency range to be scanned. Select a set from the list, and click on Add to Scanning List. With PCTEL EX scanning receivers, the internal frequency range is defined with start frequency, resolution bandwidth (RBW) and number of points. Stop frequency = start frequency + (frequency spacing) * (number of points – 1). All the points need to be within the frequency range of the requested RF Band. Frequency spacing is between the center frequencies and spacing between points is half of the resolution bandwidth. The maximum number of samples (points) is 2560. As seen in the formula above, stop frequency is calculated based on start frequency and number of points. Stop frequency set by the user is only requested value but it is not necessarily used during the measurement.
  • 103. PCT EL 10 3 If the requested frequency range is not supported by the device, Nemo Outdoor automatically adjusts the frequency range for the device, and only frequency ranges supported by the scanning receiver are used to make spectrum analyzer measurements. The number of samples is used only for the frequency range supported by the scanning receiver. Nemo Outdoor does not read the supported frequency range from the scanning receiver. For example, in the picture below the user has set start and stop frequencies as seen within the red area. However, the scanning receiver supports only frequency ranges shown by the green areas. The number of samples is used only for green areas and the correct RBW is selected accordingly. 7. Click OK to return to the Spectrum scanning page.
  • 104. PCT EL 10 4 8. The added frequency ranges will be added to the Scanning list. 9. To remove items from the scanning list, select one or more, and select Remove All | Remove Selected Items. Alternatively, click on Remove All to remove every item from the list. 10. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 11. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 12. Click the Start Recording button to start recording the results in an output file.
  • 105. PCT EL 10 5 LTE OFDM Scanning OFDM scanning can be used for scanning Reference signal / Sync signals with a PCTEL LTE scanner and Nemo Outdoor. 1. After the PCTEL LTE scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here you can enable and disable the integrated GPS receiver. This means you will not need an external GPS receiver in order to collect position data. 3. In the Measurement Properties dialog, go to the Pilot scanning page. Channel style refers to the style of the channel. Cyclic prefix defines the type of signal the scanner is set to measure. With Autodetect selected, the scanner will automatically detect the appropriate signal type. Data processing method defines how the scanned data is processed by the scanner. In aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
  • 106. PCT EL 10 6 Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1, 1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every th th second sample is logged, with ratio 1:4 every 4 sample is logged, and with ratio 1:8 every 8 sample is logged. By decreasing the sampling ratio you can decrease the output file size, but the scanning accuracy will be diminished. RSSI threshold determines a valid path (in dB). Subtracting the set value from a path with a maximum correlation value gives the lower limit of the valid path. Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report results from N best cells. Number of cells field indicates the number of best cells you want the scanning to notify you of. Up to 16 sectors are reported with specific cell ID. CINR option activates/deactivates Carrier to Interference and Noise Ratio measuring. Carrier refers to either reference signal power or sync signal power depending on the selected signal type. Time offset refers to the number of samples between P-SCH Primary Synchronization Signal arrival time with respect to receiver frequency reference that is derived from GPS reference time. Sync signal refers to the ratio between the synchronization channel, i.e., primary and secondary signal received power and the interference and noise from the same synchronization signal set. Reference signal refers to the ratio between the reference signal received power (RSRP) and the interference and noise from the same reference signal set. The Top-N Configuration button will open the Select Channels where you can select channels for pilot scanning. The maximum number of channels that can be selected is device specific.
  • 107. PCT EL 10 7 4. When you select LTE channels, you can also define some channel-specific settings. In the LTE Channel Specific Settings dialog, select the channel from the Selected channels list and define the settings. ♦ Note that the available options are device specific. Uplink-downlink configuration refers to LTE TDD frame structure. Frame structure type 2 is applicable to TDD. Each radio frame of length Tf = 307200 ⋅ Ts = 10 ms consists of two half-frames of length 153600 ⋅Ts = 5 ms each. Each half-frame consists of five subframes of length 30720 ⋅Ts = 1 ms . The supported uplink-downlink configurations are listed in the table below where, for each subframe in a radio frame, “D” denotes the subframe is reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS. One radio frame, Tf = 307200Ts = 10 ms One half-frame, 153600Ts = 5 ms One slot, Tslot=15360Ts 30720Ts Subframe #0 Subframe #2 One subframe, 30720Ts DwPTS GP Subframe #3 Subframe #4 Subframe #7 Subframe #5 UpPT S DwPTS GP Subframe #8 Subframe #9 UpPT S Frame structure type 2 (for 5 ms switch-point periodicity): Uplink-downlink configuration Downlink-to-Uplink Switch-point periodicity 0 1 2 Subframe number 3 4 5 6 7 8 9
  • 108. PCT EL 10 8 0 1 2 3 4 5 6 5 ms 5 ms 5 ms 10 ms 10 ms 10 ms 5 ms D D D D D D D S S S S S S S U U U U U U U U U D U U D U U D D U D D U D D D D D D D S S S D D D S U U U D D D U U U D D D D U U D D D D D D 5. After making the appropriate settings, click OK and OK again and go to online mode to start the scanning. 6. A green light on the scanner Device Status window should start blinking. This means that the device is working properly and scanning using the default settings. 7. Click the Start Recording button to start recording the results in an output file. Pilot Scrambling Code Scanning Known Scrambling Code Scanning can be used to scan known pilots. The Known Scrambling Code Scanning will from now on be referred to as Normal Pilot Mode. 1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> | General Properties. 2. In the Measurement Properties dialog, go to the Pilot scanning page.