SlideShare uma empresa Scribd logo
1 de 2
Baixar para ler offline
Gas Detection
FE ATURES & BENEFITS
Sensepoint XRL
Fixed Gas Detector
Sensepoint XRL is a fixed point gas leak detector that is designed to
meet the needs of industrial applications. With over 50 years experience
in gas leak detection, Honeywell offers a flexible range of highly-reliable
sensing devices to meet those needs.
•	 Quick installation
•	 Rapid configuration
•	 Simple to operate
•	 Straightforward to maintain
Honeywell innovation enables customers to pair the gas detector with
their mobile phone, and then use an app to perform many tasks related
to installation, commissioning and maintenance.
Flexible Output Options
Sensepoint XRL is available with either mA loop analog output
or Modbus RTU. The result is a flexible solution that can easily be
incorporated into legacy systems as well as new installations.
Easy Control and Maintenance
Sensepoint XRL's smartphone interface makes for much faster
calibration, configuration and bump tests. Inspecting the status and
settings of individual Sensepoint XRL detectors is simple. Use the
mobile app to:
•	 Read gas concentrations in real-time
•	 Reconfigure settings
•	 Check unit histories
Automated Reporting
Increase the efficiency of your operations and reduce administration
time. The app and Sensepoint XRL provides easy access to diagnostic
information and generates calibration reports at the touch of a screen.
Compatible System Controller
Touchpoint Plus is the perfect complement to Sensepoint XRL, providing
an intuitive, easy to operate gas detection solution to meet the needs of
your business.
Visual Integration
Clean aesthetics and a choice of colors mean
that the detector appearance can be selected
to compare or contrast with the environment in
which it is being used.
Typical Applications
•	 Manufacturing facilities and factories
•	 Water treatment plants
•	 Battery charging facilities
•	 Vehicle test facilities
•	 Petrochemical plants
•	 Fuelling depots
Accessories
•	 Calibration cap
•	 Collecting cone
•	 Pole Mount Bracket Kit
•	 Duct Mount Kit
•	 Weather Protection
•	 Flow Housing
•	Choose from a
range of mA or
Modbus output
versions for flexible
system design to
meet the
customers
requirements.	
•	Selectable source
or sink current for
analog output
enables one
detector to be
suitable for both
system
configurations.
•	The ingress
protection of NEMA
4X/IP66 allows
units to be installed
in outdoor
environemtns.
•	Simplified
maintenance with
familiar
smartphone
technology saves
money and time.
•	Multi-color visual
indicator to show
status makes it
easier to  know the
detector status
immediately and
identify detectors
that require
attention or are
warning of danger.
•	Manage the
detector without
making a physical
connection.
Remove the need
for physical access
to hard-to-reach
devices.
•	One person
calibration without
the need to open
the detector. Saves
time and removes
need for hot work
permit.
ARJAY Automation, LLC | (800) 761-1749 | www.arjaynet.com
Sensepoint XRLTechnical Specifications
For more information
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution GmbH
Tel: 00800 333 222 44 (Freephone number)
Tel: +41 44 943 4380 (Alternative number)
Middle East Tel: +971 4 450 5800 (Fixed gas detection)
Middle East Tel: +971 4 450 5852 (Portable gas
detection)
Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
RAE Systems by Honeywell
Phone: 408.952.8200
Toll Free: 1.888.723.4800
Asia Pacific, India
Honeywell Analytics Asia Pacific
North Asia Tel: +82 (0) 2 6909 0300
South East Asia Tel: +65 6580 3662
India Tel: +91 124 4752700
China Tel: +86 10 5885 8788-3000
www.honeywell.com
DS_01178 | Rev. 01 | 08/2017
© 2017 Honeywell International Inc.
PHYSICAL PROPERTIES
DIMENSIONS 118 x 159 x 93 mm
( 4.4 x 6.2 x 3.6 in )
WEIGHT 1400 g (3.1 lb)
CASING MATERIAL Aluminum alloy LM20 (charcoal or yellow)
INGRESS PROTECTION
RATING
IP66, NEMA 4X
LIFETIME 10 years (excludes sensor)
AVAILABLE SENSORS
FLAMMABLE, TOXIC GASES
AND OXYGEN RANGES
•	 Combustible: O to 100 % LEL (adjustable
between 20 and 100% LEL, Factory calibrated
to Methane)
•	 O₂: 0 to 25% vol
•	 CO: O to 300 ppm (adjustable between
50 and 1000 ppm)
•	 H₂: O to 1000 ppm
•	 H₂S Low Range: 0 to 50 ppm (adjustable between
10 and 50 ppm)
•	 H₂S High Range: 0 to 100 ppm (adjustable
between 50 and 200 ppm)
POWER SUPPLY
DC INPUT VOLTAGE 24 V DC†
AC INPUT VOLTAGE 24 V AC‡, 50/60 Hz
INRUSH CURRENT 850 mA
OUTPUT
ANALOG OUTPUT 0 to 22 mA
DIGITAL OUTPUT Modbus RTU
MAXIMUM POWER CONSUMPTION
mA VERSIONS < 1.5 W (toxic), < 2.6 W (flammable)
MODBUS VERSIONS < 1.0 W (toxic), < 2.0 W (flammable)
CONNECTION
TYPE Pluggable rising clamp style,
0.5 to 2.5 mm2
, 20 to 13 AWG
†	
mA versions: 11 to 32 VDC, Modbus versions: 9 to 32 VDC
‡ 	
All versions: 20 to 27 VAC
USER INTERFACE
VISUAL INDICATOR Multi-colour LED light ring
•	 Flashing green: Normal§
•	 Flashing red: Alarm
•	 Flashing green and yellow: Warning
•	 Flashing yellow: Fault
•	 Solid yellow: Inhibited
•	 Flashing blue: Bluetooth pairing in progress
•	 Solid blue: Bluetooth connection established
WIRELESS INTERFACE Bluetooth 4.0 (Bluetooth Low Energy). Dedicated
mobile app, enabling wireless configuration and
maintenance. Connect up to 10 m (30 ft) away
(mobile device dependent). Use a compatible
smartphone or other mobile device running Android
4.3 or above.
OPERATING ENVIRONMENT
OPERATING TEMPERATURE −40 to 65 °C (−40 to 140 °F)
STORAGE TEMPERATURE 0 to 30 °C (32 to 86 °F)
HUMIDITY 0 to 99% (non-condensing)
ATMOSPHERIC PRESSURE 90 to 110 kPa
CERTIFICATIONS
ELECTRICAL SAFETY EN/IEC/UL 61010-1
CSA C22.2 No. 61010-1-12
EMC EN 50270:2015
RADIO RED, FCC, IC
HAZARDOUS AREA •	 ATEX
II 2 GD
Ex db IIC T6 Gb
Ex tb IIIC T85 °C Db
Tamb −40 to +65 °C
•	 IECEx
Ex db IIC T6 Gb
Ex tb IIIC T85 °C Db
Tamb −40 to +65 °C
•	 cULus
Class I, Division 1 & 2, Groups B, C and D
Class II, Division 1 & 2, Groups E, F and G
Class I, Zone 1, AEx db IIC T6
Zone 21, AEx tb IIIC T85°C, IP6X
Ex db IIC T6 GbX
Ex tb IIIC T85°C DbX
Tamb −40 to +65 °C, Temp Code T6
GAS PERFORMANCE CSA C22.2 No.152-M1984, UL 2075, AS 1668.2
§
	 LED behavior in normal condition can be changed by the user: green confidence flash, solid
green or off.
ARJAY Automation, LLC | (800) 761-1749 | www.arjaynet.com

Mais conteúdo relacionado

Mais de Arjay Automation

Combustion Airflow Measurement Station
Combustion Airflow Measurement StationCombustion Airflow Measurement Station
Combustion Airflow Measurement StationArjay Automation
 
Nivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical IndustriesNivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical IndustriesArjay Automation
 
Turbine Flowmeters for Liquids
Turbine Flowmeters for LiquidsTurbine Flowmeters for Liquids
Turbine Flowmeters for LiquidsArjay Automation
 
Magnetostrictive Liquid Level Transmitters
Magnetostrictive Liquid Level TransmittersMagnetostrictive Liquid Level Transmitters
Magnetostrictive Liquid Level TransmittersArjay Automation
 
Sanitary Industrial Pressure Transmitters
Sanitary Industrial Pressure TransmittersSanitary Industrial Pressure Transmitters
Sanitary Industrial Pressure TransmittersArjay Automation
 
Combustion and Fired Heater Optimization
Combustion and Fired Heater OptimizationCombustion and Fired Heater Optimization
Combustion and Fired Heater OptimizationArjay Automation
 
Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections
Programmable Limit Alarm Trips with Intrinsically-Safe Field ConnectionsProgrammable Limit Alarm Trips with Intrinsically-Safe Field Connections
Programmable Limit Alarm Trips with Intrinsically-Safe Field ConnectionsArjay Automation
 
Continuous Conductivity Monitoring Instrument for Industrial Applications
Continuous Conductivity Monitoring Instrument for Industrial ApplicationsContinuous Conductivity Monitoring Instrument for Industrial Applications
Continuous Conductivity Monitoring Instrument for Industrial ApplicationsArjay Automation
 
Continuous Measuring Gas Density Meters
Continuous Measuring Gas Density MetersContinuous Measuring Gas Density Meters
Continuous Measuring Gas Density MetersArjay Automation
 
Functional Safety Frequency to DC Transmitter
Functional Safety Frequency to DC TransmitterFunctional Safety Frequency to DC Transmitter
Functional Safety Frequency to DC TransmitterArjay Automation
 
Industrial Wireless Network Components and Equipment
Industrial Wireless Network Components and EquipmentIndustrial Wireless Network Components and Equipment
Industrial Wireless Network Components and EquipmentArjay Automation
 
Hydrostatic Liquid Level Transmitters for Industrial Process Measurement
Hydrostatic Liquid Level Transmitters for Industrial Process MeasurementHydrostatic Liquid Level Transmitters for Industrial Process Measurement
Hydrostatic Liquid Level Transmitters for Industrial Process MeasurementArjay Automation
 
Wearable Multi-Gas Detector for Personnel Safety
Wearable Multi-Gas Detector for Personnel SafetyWearable Multi-Gas Detector for Personnel Safety
Wearable Multi-Gas Detector for Personnel SafetyArjay Automation
 
High-performance Controller for Industrial Weighing
High-performance Controller for Industrial WeighingHigh-performance Controller for Industrial Weighing
High-performance Controller for Industrial WeighingArjay Automation
 
Process gas chromatograph for industrial process measurement
Process gas chromatograph for industrial process measurementProcess gas chromatograph for industrial process measurement
Process gas chromatograph for industrial process measurementArjay Automation
 
Prozess Technologie REVEAL Platform
Prozess Technologie REVEAL PlatformProzess Technologie REVEAL Platform
Prozess Technologie REVEAL PlatformArjay Automation
 
Flexible Industrial Temperature Sensors
Flexible Industrial Temperature SensorsFlexible Industrial Temperature Sensors
Flexible Industrial Temperature SensorsArjay Automation
 
Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...
Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...
Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...Arjay Automation
 
pH and ORP Learning Handbook
pH and ORP Learning HandbookpH and ORP Learning Handbook
pH and ORP Learning HandbookArjay Automation
 
Transfer Switching with Breakers ... In Less Than 2 Cycles
Transfer Switching with Breakers ... In Less Than 2 CyclesTransfer Switching with Breakers ... In Less Than 2 Cycles
Transfer Switching with Breakers ... In Less Than 2 CyclesArjay Automation
 

Mais de Arjay Automation (20)

Combustion Airflow Measurement Station
Combustion Airflow Measurement StationCombustion Airflow Measurement Station
Combustion Airflow Measurement Station
 
Nivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical IndustriesNivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical Industries
 
Turbine Flowmeters for Liquids
Turbine Flowmeters for LiquidsTurbine Flowmeters for Liquids
Turbine Flowmeters for Liquids
 
Magnetostrictive Liquid Level Transmitters
Magnetostrictive Liquid Level TransmittersMagnetostrictive Liquid Level Transmitters
Magnetostrictive Liquid Level Transmitters
 
Sanitary Industrial Pressure Transmitters
Sanitary Industrial Pressure TransmittersSanitary Industrial Pressure Transmitters
Sanitary Industrial Pressure Transmitters
 
Combustion and Fired Heater Optimization
Combustion and Fired Heater OptimizationCombustion and Fired Heater Optimization
Combustion and Fired Heater Optimization
 
Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections
Programmable Limit Alarm Trips with Intrinsically-Safe Field ConnectionsProgrammable Limit Alarm Trips with Intrinsically-Safe Field Connections
Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections
 
Continuous Conductivity Monitoring Instrument for Industrial Applications
Continuous Conductivity Monitoring Instrument for Industrial ApplicationsContinuous Conductivity Monitoring Instrument for Industrial Applications
Continuous Conductivity Monitoring Instrument for Industrial Applications
 
Continuous Measuring Gas Density Meters
Continuous Measuring Gas Density MetersContinuous Measuring Gas Density Meters
Continuous Measuring Gas Density Meters
 
Functional Safety Frequency to DC Transmitter
Functional Safety Frequency to DC TransmitterFunctional Safety Frequency to DC Transmitter
Functional Safety Frequency to DC Transmitter
 
Industrial Wireless Network Components and Equipment
Industrial Wireless Network Components and EquipmentIndustrial Wireless Network Components and Equipment
Industrial Wireless Network Components and Equipment
 
Hydrostatic Liquid Level Transmitters for Industrial Process Measurement
Hydrostatic Liquid Level Transmitters for Industrial Process MeasurementHydrostatic Liquid Level Transmitters for Industrial Process Measurement
Hydrostatic Liquid Level Transmitters for Industrial Process Measurement
 
Wearable Multi-Gas Detector for Personnel Safety
Wearable Multi-Gas Detector for Personnel SafetyWearable Multi-Gas Detector for Personnel Safety
Wearable Multi-Gas Detector for Personnel Safety
 
High-performance Controller for Industrial Weighing
High-performance Controller for Industrial WeighingHigh-performance Controller for Industrial Weighing
High-performance Controller for Industrial Weighing
 
Process gas chromatograph for industrial process measurement
Process gas chromatograph for industrial process measurementProcess gas chromatograph for industrial process measurement
Process gas chromatograph for industrial process measurement
 
Prozess Technologie REVEAL Platform
Prozess Technologie REVEAL PlatformProzess Technologie REVEAL Platform
Prozess Technologie REVEAL Platform
 
Flexible Industrial Temperature Sensors
Flexible Industrial Temperature SensorsFlexible Industrial Temperature Sensors
Flexible Industrial Temperature Sensors
 
Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...
Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...
Practical Issues of Combustion Oxygen Measurement Specifically Related to NOx...
 
pH and ORP Learning Handbook
pH and ORP Learning HandbookpH and ORP Learning Handbook
pH and ORP Learning Handbook
 
Transfer Switching with Breakers ... In Less Than 2 Cycles
Transfer Switching with Breakers ... In Less Than 2 CyclesTransfer Switching with Breakers ... In Less Than 2 Cycles
Transfer Switching with Breakers ... In Less Than 2 Cycles
 

Último

Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringmulugeta48
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Christo Ananth
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01KreezheaRecto
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTbhaskargani46
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdfankushspencer015
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfJiananWang21
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXssuser89054b
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueBhangaleSonal
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptMsecMca
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 

Último (20)

Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 

Honeywell Analytics Sensepoint XRL

  • 1. Gas Detection FE ATURES & BENEFITS Sensepoint XRL Fixed Gas Detector Sensepoint XRL is a fixed point gas leak detector that is designed to meet the needs of industrial applications. With over 50 years experience in gas leak detection, Honeywell offers a flexible range of highly-reliable sensing devices to meet those needs. • Quick installation • Rapid configuration • Simple to operate • Straightforward to maintain Honeywell innovation enables customers to pair the gas detector with their mobile phone, and then use an app to perform many tasks related to installation, commissioning and maintenance. Flexible Output Options Sensepoint XRL is available with either mA loop analog output or Modbus RTU. The result is a flexible solution that can easily be incorporated into legacy systems as well as new installations. Easy Control and Maintenance Sensepoint XRL's smartphone interface makes for much faster calibration, configuration and bump tests. Inspecting the status and settings of individual Sensepoint XRL detectors is simple. Use the mobile app to: • Read gas concentrations in real-time • Reconfigure settings • Check unit histories Automated Reporting Increase the efficiency of your operations and reduce administration time. The app and Sensepoint XRL provides easy access to diagnostic information and generates calibration reports at the touch of a screen. Compatible System Controller Touchpoint Plus is the perfect complement to Sensepoint XRL, providing an intuitive, easy to operate gas detection solution to meet the needs of your business. Visual Integration Clean aesthetics and a choice of colors mean that the detector appearance can be selected to compare or contrast with the environment in which it is being used. Typical Applications • Manufacturing facilities and factories • Water treatment plants • Battery charging facilities • Vehicle test facilities • Petrochemical plants • Fuelling depots Accessories • Calibration cap • Collecting cone • Pole Mount Bracket Kit • Duct Mount Kit • Weather Protection • Flow Housing • Choose from a range of mA or Modbus output versions for flexible system design to meet the customers requirements. • Selectable source or sink current for analog output enables one detector to be suitable for both system configurations. • The ingress protection of NEMA 4X/IP66 allows units to be installed in outdoor environemtns. • Simplified maintenance with familiar smartphone technology saves money and time. • Multi-color visual indicator to show status makes it easier to know the detector status immediately and identify detectors that require attention or are warning of danger. • Manage the detector without making a physical connection. Remove the need for physical access to hard-to-reach devices. • One person calibration without the need to open the detector. Saves time and removes need for hot work permit. ARJAY Automation, LLC | (800) 761-1749 | www.arjaynet.com
  • 2. Sensepoint XRLTechnical Specifications For more information www.honeywellanalytics.com Europe, Middle East, Africa Life Safety Distribution GmbH Tel: 00800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number) Middle East Tel: +971 4 450 5800 (Fixed gas detection) Middle East Tel: +971 4 450 5852 (Portable gas detection) Americas Honeywell Analytics Distribution Inc. Tel: +1 847 955 8200 Toll free: +1 800 538 0363 RAE Systems by Honeywell Phone: 408.952.8200 Toll Free: 1.888.723.4800 Asia Pacific, India Honeywell Analytics Asia Pacific North Asia Tel: +82 (0) 2 6909 0300 South East Asia Tel: +65 6580 3662 India Tel: +91 124 4752700 China Tel: +86 10 5885 8788-3000 www.honeywell.com DS_01178 | Rev. 01 | 08/2017 © 2017 Honeywell International Inc. PHYSICAL PROPERTIES DIMENSIONS 118 x 159 x 93 mm ( 4.4 x 6.2 x 3.6 in ) WEIGHT 1400 g (3.1 lb) CASING MATERIAL Aluminum alloy LM20 (charcoal or yellow) INGRESS PROTECTION RATING IP66, NEMA 4X LIFETIME 10 years (excludes sensor) AVAILABLE SENSORS FLAMMABLE, TOXIC GASES AND OXYGEN RANGES • Combustible: O to 100 % LEL (adjustable between 20 and 100% LEL, Factory calibrated to Methane) • O₂: 0 to 25% vol • CO: O to 300 ppm (adjustable between 50 and 1000 ppm) • H₂: O to 1000 ppm • H₂S Low Range: 0 to 50 ppm (adjustable between 10 and 50 ppm) • H₂S High Range: 0 to 100 ppm (adjustable between 50 and 200 ppm) POWER SUPPLY DC INPUT VOLTAGE 24 V DC† AC INPUT VOLTAGE 24 V AC‡, 50/60 Hz INRUSH CURRENT 850 mA OUTPUT ANALOG OUTPUT 0 to 22 mA DIGITAL OUTPUT Modbus RTU MAXIMUM POWER CONSUMPTION mA VERSIONS < 1.5 W (toxic), < 2.6 W (flammable) MODBUS VERSIONS < 1.0 W (toxic), < 2.0 W (flammable) CONNECTION TYPE Pluggable rising clamp style, 0.5 to 2.5 mm2 , 20 to 13 AWG † mA versions: 11 to 32 VDC, Modbus versions: 9 to 32 VDC ‡ All versions: 20 to 27 VAC USER INTERFACE VISUAL INDICATOR Multi-colour LED light ring • Flashing green: Normal§ • Flashing red: Alarm • Flashing green and yellow: Warning • Flashing yellow: Fault • Solid yellow: Inhibited • Flashing blue: Bluetooth pairing in progress • Solid blue: Bluetooth connection established WIRELESS INTERFACE Bluetooth 4.0 (Bluetooth Low Energy). Dedicated mobile app, enabling wireless configuration and maintenance. Connect up to 10 m (30 ft) away (mobile device dependent). Use a compatible smartphone or other mobile device running Android 4.3 or above. OPERATING ENVIRONMENT OPERATING TEMPERATURE −40 to 65 °C (−40 to 140 °F) STORAGE TEMPERATURE 0 to 30 °C (32 to 86 °F) HUMIDITY 0 to 99% (non-condensing) ATMOSPHERIC PRESSURE 90 to 110 kPa CERTIFICATIONS ELECTRICAL SAFETY EN/IEC/UL 61010-1 CSA C22.2 No. 61010-1-12 EMC EN 50270:2015 RADIO RED, FCC, IC HAZARDOUS AREA • ATEX II 2 GD Ex db IIC T6 Gb Ex tb IIIC T85 °C Db Tamb −40 to +65 °C • IECEx Ex db IIC T6 Gb Ex tb IIIC T85 °C Db Tamb −40 to +65 °C • cULus Class I, Division 1 & 2, Groups B, C and D Class II, Division 1 & 2, Groups E, F and G Class I, Zone 1, AEx db IIC T6 Zone 21, AEx tb IIIC T85°C, IP6X Ex db IIC T6 GbX Ex tb IIIC T85°C DbX Tamb −40 to +65 °C, Temp Code T6 GAS PERFORMANCE CSA C22.2 No.152-M1984, UL 2075, AS 1668.2 § LED behavior in normal condition can be changed by the user: green confidence flash, solid green or off. ARJAY Automation, LLC | (800) 761-1749 | www.arjaynet.com