Dear user: Thank you very much for selecting our product! This manual offers important information and suggestions about use and troubleshooting, etc. Please read this manual carefully before using the product. Warranty: The product is warranted to be free from defects for a period of two years from the date of shipment to the original end user.
Contents 
1 Important Safety Information ............................................ 1 
2 General Information ........................................................ 1 
2.1 Product Characteristic ................................................... 1 
2.2 Main Functions ............................................................ 2 
2.3 Recommendation ......................................................... 2 
3 Features ........................................................................ 3 
3.1 Features...................................................................... 3 
3.2 Power Supply and Startup .............................................. 5 
4 Software Operation ......................................................... 7 
4.1 Software Operating Environment..................................... 7 
4.2 Software Installation and Uninstalling .............................. 7 
4.3 Software Operating Instructions ...................................... 7 
5 Specification ................................................................ 22 
5.1 Hardware Configuration .............................................. 22 
5.2 SPP-01 Parameter....................................................... 22 
6 SPP-01 Overall Dimension ............................................. 23
1 
1 Important Safety Information 
This manual contains important safety, setting and operating instructions for SPP-01. Save these instructions. 
 Please inspect the product thoroughly after it is delivered. If any damage is seen, please notify the shipping company or our company immediately. 
 Read of the instructions and cautions in the manual before using. 
 Keep the product away from rain, exposure, severe dust, vibrations, corrosive gas and intense electromagnetic interference. 
 Do not allow water to enter the controller. 
 Do not disassemble or attempt to repair it. 
2 General Information 
2.1 Product Characteristic 
Super parameter programmer (SPP-01) is the simple, efficient and practical accessory for parameter configuration with the easy one button operation. Due to the new standard communication protocol, it applies to stand-alone or multi-parallel products. The features of the SPP-01 are listed below. 
 One button and one indication led are designed for simplicity and easy-to-operate. 
 RS232 (TTL), RS485 and USB communication are supported. 
 SPPPCTools PC software is used to configure and backup parameters
2 
visually, rapidly and conveniently. 
 Dual power supply design. SPP-01 can be powered by battery or Micro-USB cable applying for various environments. 
2.2 Main Functions 
 Parameter configuration function 
Load the parameter configuration to the SPP-01 via SPPPCTools PC software and then update the device’s parameters through SPP-01 with easy one button. 
 Data transparent transmission function. 
SPP-01 can be used as the communication converter to connect the device and Solar Station Monitor, a PC software, to establish remote monitoring. 
2.3 Recommendation 
DCCPxxxxDP (R), LSxxxxB (PL), VSxxxxB, TracerxxxxB (PL) and iTracerxxB series products are supported to update the configuration by SPP-01. Please confirm whether to support before purchasing.
3 
3 Features 
3.1 Features 
Description 
Operation 
Remarks 
K1(Toggle switch1) 
COM 
Communication converter mode 
MEM 
Parameter configuration mode 
K2(Toggle switch 2) 
Line 
Wire communication mode 
IrDA 
Reserved 
K3(Toggle switch 3) 
On 
Power on 
Off 
Power off 
K4(Water proof key 4) 
Press the button 
Press the key to enter configuration mode (the indicator led is on), click it again to update the configuration. 
Press and hold the button 
Test “Turn on” or “Turn off” the load. 
Indicator led and buzzer 
Configuration mode 
The indicator led is on without a beep. 
Update 
The indicator led flashes once 
K1 
K2 
K3 
LED 
K4
4 
successfully. 
with one short beep. 
Communication error 
The indicator led flashes twice with two short beeps. 
The model is not matched or the irrational configuration 
The indicator led flashes triple with three short beeps. 
Test 
The indicator light flashes for several times with one long beep. 
Note: 
1. Press and hold the button for three seconds to alternately turn on or turn off the load in the testing mode. After 3 minutes, the device will quit the test mode automatically. 
2. In the testing mode, the SPP-01 can switch the load no matter whether it has loaded the configuration or not. 
RJ11 
RJ45
5 
Description 
Operating 
Remarks 
RJ11 interface 
Connect the controller with the CC-TTL-TTL-150U communication cable 
Update device configure 
RJ45 interface 
Connect the controller with the CC-RS485- RS485-150U communication cable 
Update device configure 
USB interface 
Connect to the PC with the CC-USB-USB-150U communication cable 
Update SPP01 configure 
RTC battery holder 
Battery for real-time time clock 
Type: CR1220 
Battery compartment 
3 batteries 
Size AAA 
3.2 Power Supply and Startup 
The SPP-01 is powered by following three methods: 
1. Get power via the USB data cable from USB interface. 
RTC Battery 
Battery compartment 
USB interface
6 
2. Get power via exclusive data cable from the device. 
3. Get power from 3 batteries (size AAA). 
Starting SPP-01: The SPP-01 is powered on by toggling K3 switch to “ON” 
Operating status 
Phenomena 
Normal startup 
The green light flashes once with one beep. 
No data available in SPP-01 
The green light flashes for several times with several beeps.
7 
4 Software Operation 
4.1 Software Operating Environment 
 Hardware Environment 
 A Pentium 4-compatible PC 
 At least 512Mbyte of RAM and 55Mbyte of free disk space 
 Software Operating Environment 
The recommended operating system is as follows: 
 Windows XP (32bit), Win7 (32bit/64bit), Win8 (32bit/64bit) 
 Installing component: Windows Installer3_1, DotNetFX40. 
4.2 Software Installation and Uninstalling 
 Installing the software 
Open directory “SPPPCSoftwareV3.77”, and double click “setup.exe”, after the computer start carry on the software gearing. 
 Uninstalling the software 
Click the Start >Control Panel >Add or delete programs> SPP> Delete. 
4.3 Software Operating Instructions 
 Get serial port number for SPP-01 
1. Connect the device: Connect SPP-01 to the PC with the Micro-USB cable and turn K3 switch to “ON” position. The SPP-01 starts normally with indicator led flashing once and a short beep.
8 
2. Install SPP-01 serial port driver: Open directory “SPP USB Driver” and run “Setup.bat” file to install the driver. 
3. Right click “My computer > Property > Hardware > Device manager” to pop up a device manager window, seeing the figure below: 
Note: The serial port number selected in the figure above is the serial port number of SPP-01 (COM8).
9 
 Main interface 
Parameter configure: 
1. Double click software icon to pop up configuration interface of SPP-01. 
2. The software will automatically open the port after selected serial port of SPP-01(the button caption will change from “open port” to “close port”) 
3. The following dialog box will be popped up automatically by clicking “SELECT” tag:
10 
Double click to select device (the configuration content will be changed automatically). 
4. Configure relevant parameters by clicking “Control Parameters”, “General Load”, “LED Load” in the frame of Parameter Configuration and “Time Sync” in the Management. After configuring parameters, click “OK” to quit and return to main interface (For the parameters without configuration, uncheck the box “ ”). 
5. After configuration, click button to load configuration into SPP-01 device (a corresponding dialog box will be popped up to prompt whether loaded successfully or not). 
Reading parameter data 
If the configuration has been loaded to the SPP-0, click button to upload the configuration in SPP-01 to PC, and refresh the corresponding parameter configuration in “Parameter configuration” frame, such as Control Parameter, General Load or LED Load, Time Sync so as to view and modify the parameters. 
Data clearing 
If it is required to clear configuration in SPP-01, click button directly. 
Importing and exporting parameter configuration 
If it is required to backup parameter configuration, click
11 
button to save the configuration as a text file with extension of .TXT. If it is required to import configuration backed up previously, click button to load corresponding TXT file to upload the configuration. 
 Control Parameter 
Battery type 
Battery type 
Notes 
Sealed (default) 
Fixed controlling voltage, unable to be modified 
Gel 
Fixed controlling voltage, unable to be modified 
Flooded 
Fixed controlling voltage, unable to be modified 
User 
Users can modify voltage controlling points.
12 
Charging Mode 
Charging mode 
Notes 
Voltage compensation 
Voltage control charging (default) 
SOC 
Set the charge and discharge SOC target values for battery charge and discharge control 
Other Control Parameter 
Parameters 
Default 
Range 
Battery Ah 
200Ah 
1~9999Ah 
Temperature compensation coefficient 
-3mV/ºC/2V 
-9~-0mV 
Rated Voltage 
Auto 
Auto/12V/24V/36V/48V 
Battery charging 
100% 
100%(SOC Mode) 
Battery discharging 
30% 
10~80%(SOC Mode) 
Note: Battery charging voltage ≥ Battery discharge+10% or battery discharge value ≤ Battery charge-10% value Battery Voltage Parameters (values are in 12V system at 25ºC, please double in 24V, triple in 36 V, and quadruple in 48 V system) 
Battery type 
Sealed 
Gel 
Flooded 
User 
High Volt Disconnect 
16V 
16V 
16V 
9~17V 
Charging Limit Voltage 
15V 
15V 
15V 
9~17V 
Over Voltage Reconnect 
15V 
15V 
15V 
9~17V 
Equalize Charging 
—— 
14.6V 
14.8V 
9~17V
13 
Boost Charging Voltage 
14.2V 
14.4V 
14.6V 
9~17V 
Float Charging Voltage 
13.8V 
13.8V 
13.8V 
9~17V 
Boost Return Voltage 
13.2V 
13.2V 
13.2V 
9~17V 
Low Voltage Reconnect 
12.6V 
12.6V 
12.6V 
9~17V 
Under Voltage Recover 
12.2V 
12.2V 
12.2V 
9~17V 
Under Voltage Warning 
12V 
12V 
12V 
9~17V 
Low Voltage Disconnect Voltage 
11.1V 
11.1V 
11.1V 
9~17V 
Discharging Limit Voltage 
10.6V 
10.6V 
10.6V 
9~17V 
Equalize Duration 
—— 
120 Min. 
120 Min. 
0~180 Min. 
Boost Duration 
120 Min. 
120 Min. 
120 Min. 
10~180 Min. 
Note: The following rules must be observed when modify the parameters value in user battery type (factory default value is the same as sealed type): 
 High Volt Disconnect > Charging limit voltage ≥ Equalization voltage ≥ Boost voltage ≥ Float voltage > Boost return voltage 
 High Volt Disconnect > Over Voltage Reconnect 
 Low Voltage Reconnect > Low Voltage Disconnect ≥ Discharging Limit Voltage 
 Under Voltage Warning Reconnect > Under Voltage Warning ≥ Discharging Limit Voltage 
 Boost Reconnect Charging voltage > Low Voltage Disconnect
14 
 Load Configuration 
Load Mode 
 Manual (load can be switched by manual button or remote control command) 
On by default 
Controller switches on the load output once initialized and keep constant output on condition that the battery is enough electricity and no abnormal situation.
15 
Off by default 
Controller keep the load output off before, during and after initialized. The load can be switched on only when doing “Manual On by default” operation and the battery is enough electricity and no abnormal situation. 
 Time Control 
Time1(T1) 
Control on/off time1 of load through real-time clock mode. 
Time2(T2) 
Control on/off time2 of load in dual time mode. 
 Light ON/OFF 
Light ON Voltage 
When input voltage of solar module goes below light ON voltage, the solar controller will recognize the starting voltage and turn on the load after pre-set time delay when the battery power is enough and the controller works well. 
Light OFF Voltage 
When input voltage of solar module goes above light OFF voltage, the solar controller will recognize the starting voltage and turn off the load after pre-set time delay. 
Delay Time 
The confirmation time for Light signal. During the period, if light signal voltage continues matching Light ON/OFF voltage, it will carry out corresponding actions(The time adjustment range:0~99mins.
16 
 Light ON+ Timer 
Working Time 1(T1) 
Load working period after light control turns ON load 
Working Time 2(T2) 
Load working period before light control turns OFF load 
Night Time 
The controller calculated the total length of the night by self-learning. The time should be more than 3 hours 
Light Control +Time Model Diagram
17 
 LED Load Configuration 
 LED Load parameter 
Parameter 
Remark 
LED Rated Current 
Rated output current. 
LED Rated Current Percentage 
Set up the parameter of the rated current percentage of the corresponding operating period of the controller; the controller will control the LED load output current according to this value.
18 
Battery Under Voltage Control 
When the battery is under this voltage, the output current will be half; when the voltage of the battery goes above it, the controller will resume the set current value automatically. 
 Manual Control(load can be switched by manual button or remote control command) 
Manually On By default 
Controller switches on the load output once initialized and keep constant output on condition that the battery is enough electricity and no abnormal situation. 
Manually Off By default 
Controller keep the load output off before, during and after initialized. The load can be switched on only when doing “Manual On by default” operation and the battery is enough electricity and no abnormal situation. 
 Time Control 
Time1(T1) 
Control on/off time1 of load through real-time clock mode. 
Time2(T2) 
Control on/off time2 of load in dual time mode. 
 Light ON/OFF 
Light ON Voltage 
When input voltage of solar module goes below light ON voltage, the solar controller will recognize the starting voltage and turn on the load after pre-set time delay when the battery power is enough and the controller works well.
19 
Light OFF Voltage 
When input voltage of solar module goes above light OFF voltage, the solar controller will recognize the starting voltage and turn off the load after pre-set time delay. 
Delay Time 
The confirmation time for Light signal. During the period, if light signal voltage continues matching Light ON/OFF voltage, it will carry out corresponding actions(The time adjustment range:0~99mins. 
 Light Control +Time Model 1 
Work Time1 (T1) 
Load working period after light control turns ON load. 
Work Time2 (T2) 
The running hour of the load after the end of the work time1. 
Work Time3 (T3) 
The running hour of the load after the end of the work time2. 
Light Control +Time1 Mode1 diagram
20 
 Light Control +Time Model 2 
Work Time1 (T1) 
Load working period after light control turns ON load. 
Work Time2 (T2) 
The running hour of the load after the end of the work time 1. 
Work Time3(T3) 
Load working period before light control turns off load. 
Night Time 
The controller calculated the total length of the night by self-learning. The time should be more than 3 hours. 
Light Control +Time2 Model diagram
21 
 Time Synchronize 
Parameters 
Remarks 
PC time 
Display PC time by default; Edit the time by clicking “Manually”. 
SPP time 
Display real-time clock of SPP-01. 
The current PC time data can be directly update to SPP-01 by clicking “Update” button; click “Manually” button to edit the values; click “Read” button to get the time from SPP-01 and display in “SPP Time” text box.
22 
5 Specification 
5.1 Hardware Configuration 
Items 
Descriptions 
Indicator light 
1 green LED indicator 
RTC clock 
The real-time clock will not be lost when the backup battery is installed. Please replace the batteries when the time of SPP-01 is not correct. 
Power supply 
From three AAA (7#) batteries; From Micro-USB cable via PC USB power; From exclusive data cable via the controller. 
Buzzer 
One built-in buzzer to prompt that communication is right or wrong. 
Communication port 
RJ11(TTL), RJ45(RS485), Micro-USB(USB). 
5.2 SPP-01 Parameter 
Parameter 
Rated 
Power Supply Voltage 
5.0V 
Static Current 
< 40 mA 
Communication Baud 
115200bps 
Working temperature 
-25ºC~+55ºC 
Enclosure 
IP30 
Overall dimension 
109 mm *60 mm *33mm 
Net weight 
80.1g
23 
6 SPP-01 Overall Dimension
Make a better use of solar 
www.ul tisolar.com
info@ultisolar.com 
http://www.ultisolar.com 
http://shop.ultisolar.com Final interpretation right of the manual belongs to our company. Any changes without prior notice! Ver1.1

Mais conteúdo relacionado

Mais procurados

S7 300 stl_programming_manual
S7 300 stl_programming_manualS7 300 stl_programming_manual
S7 300 stl_programming_manual
Paulo Sérgio
 

Mais procurados (18)

Matrix e
Matrix eMatrix e
Matrix e
 
Drv11 power flex 755 basic start
Drv11 power flex 755 basic startDrv11 power flex 755 basic start
Drv11 power flex 755 basic start
 
Hm 5750 manual-0817
Hm 5750 manual-0817Hm 5750 manual-0817
Hm 5750 manual-0817
 
User Manual_NOKEE LCD Display_King-Meter Technology Co.,Ltd
User Manual_NOKEE LCD Display_King-Meter Technology Co.,LtdUser Manual_NOKEE LCD Display_King-Meter Technology Co.,Ltd
User Manual_NOKEE LCD Display_King-Meter Technology Co.,Ltd
 
Gesture based vehicle movements control and alerting system docu
Gesture based vehicle movements control and alerting system docuGesture based vehicle movements control and alerting system docu
Gesture based vehicle movements control and alerting system docu
 
User Manual_KM5S-R LCD Display King-Meter Technology Co.,Ltd
User Manual_KM5S-R LCD Display King-Meter Technology Co.,LtdUser Manual_KM5S-R LCD Display King-Meter Technology Co.,Ltd
User Manual_KM5S-R LCD Display King-Meter Technology Co.,Ltd
 
Paxton Access 337-837-US Instruction Manual
Paxton Access 337-837-US Instruction ManualPaxton Access 337-837-US Instruction Manual
Paxton Access 337-837-US Instruction Manual
 
Siemens Automation Station Compact Model PXC52
Siemens Automation Station Compact Model PXC52Siemens Automation Station Compact Model PXC52
Siemens Automation Station Compact Model PXC52
 
Gt250 pe hmi manual (rev2)
Gt250 pe hmi manual (rev2)Gt250 pe hmi manual (rev2)
Gt250 pe hmi manual (rev2)
 
S7 300 stl_programming_manual
S7 300 stl_programming_manualS7 300 stl_programming_manual
S7 300 stl_programming_manual
 
Basics and applications of programmable logic controller (plc)
Basics and applications of programmable logic controller (plc)Basics and applications of programmable logic controller (plc)
Basics and applications of programmable logic controller (plc)
 
Catalog PLC Mitsubishi Fx 3G 60MR
Catalog PLC Mitsubishi Fx 3G 60MRCatalog PLC Mitsubishi Fx 3G 60MR
Catalog PLC Mitsubishi Fx 3G 60MR
 
Dcs overview
Dcs overviewDcs overview
Dcs overview
 
F5 m instruction manual
F5 m instruction manualF5 m instruction manual
F5 m instruction manual
 
Chapter 1
Chapter 1Chapter 1
Chapter 1
 
Volvo
VolvoVolvo
Volvo
 
Microcontroller project111
Microcontroller project111Microcontroller project111
Microcontroller project111
 
At89s52
At89s52At89s52
At89s52
 

Semelhante a SPP-01 Super Parameter Programmer User Manual Ultisolar New Energy

시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼
시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼
시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼
HION IT
 
105996292 electrical-control-automation-studio
105996292 electrical-control-automation-studio105996292 electrical-control-automation-studio
105996292 electrical-control-automation-studio
Tùng Nguyễn
 
MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)
MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)
MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)
Jonathan Assad
 

Semelhante a SPP-01 Super Parameter Programmer User Manual Ultisolar New Energy (20)

Tài liệu đào tạo simens sinamic G120
Tài liệu đào tạo simens sinamic G120Tài liệu đào tạo simens sinamic G120
Tài liệu đào tạo simens sinamic G120
 
Sinamics g120 treinamento (en)
Sinamics g120 treinamento (en)Sinamics g120 treinamento (en)
Sinamics g120 treinamento (en)
 
Pf700 energy savings_lab
Pf700 energy savings_labPf700 energy savings_lab
Pf700 energy savings_lab
 
시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼
시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼
시크 SICK Lector63x 2D DPM스캐너 고정식바코드스캐너 산업용바코드리더 이미지스캐너 매뉴얼
 
105996292 electrical-control-automation-studio
105996292 electrical-control-automation-studio105996292 electrical-control-automation-studio
105996292 electrical-control-automation-studio
 
Pcu230 pi pump_controlwithpf400drives_rev_a
Pcu230 pi pump_controlwithpf400drives_rev_aPcu230 pi pump_controlwithpf400drives_rev_a
Pcu230 pi pump_controlwithpf400drives_rev_a
 
MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)
MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)
MANUAL 120817 250KVA GENERATOR HARSEN-GU320B (1)
 
Ultisolar iT3415 iT4415 iT6415 iTracer User Manual
Ultisolar iT3415 iT4415 iT6415  iTracer User ManualUltisolar iT3415 iT4415 iT6415  iTracer User Manual
Ultisolar iT3415 iT4415 iT6415 iTracer User Manual
 
Launch X431 ECU Programmer User Manual.pdf
Launch X431 ECU Programmer User Manual.pdfLaunch X431 ECU Programmer User Manual.pdf
Launch X431 ECU Programmer User Manual.pdf
 
Tx7201 zone monitor module
Tx7201 zone monitor moduleTx7201 zone monitor module
Tx7201 zone monitor module
 
Manual radiator thermostat -Aeotec
Manual radiator thermostat -AeotecManual radiator thermostat -Aeotec
Manual radiator thermostat -Aeotec
 
Tlk43 Controller
Tlk43 ControllerTlk43 Controller
Tlk43 Controller
 
FasDiag JD101 User's Manual
FasDiag JD101 User's ManualFasDiag JD101 User's Manual
FasDiag JD101 User's Manual
 
Tlk94 Controller
Tlk94 ControllerTlk94 Controller
Tlk94 Controller
 
Pcu230 pi fan_controlwithpf400drives_rev_a
Pcu230 pi fan_controlwithpf400drives_rev_aPcu230 pi fan_controlwithpf400drives_rev_a
Pcu230 pi fan_controlwithpf400drives_rev_a
 
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
 
FasDiag OM123 User's Manual
FasDiag OM123 User's ManualFasDiag OM123 User's Manual
FasDiag OM123 User's Manual
 
manual vvtk camera_st7501
manual vvtk camera_st7501manual vvtk camera_st7501
manual vvtk camera_st7501
 
Manual_AD147_20140728.pdf
Manual_AD147_20140728.pdfManual_AD147_20140728.pdf
Manual_AD147_20140728.pdf
 
Air Gate Max Userguide
Air Gate Max UserguideAir Gate Max Userguide
Air Gate Max Userguide
 

Mais de Shandong iSentrol Electronic Technology Co., Ltd

Mais de Shandong iSentrol Electronic Technology Co., Ltd (20)

US211M digital flow meter user manual
US211M digital flow meter user manualUS211M digital flow meter user manual
US211M digital flow meter user manual
 
Ce Report of usc-hs21ti hall water flow sensor from iSentrol
Ce Report of usc-hs21ti hall water flow sensor from iSentrolCe Report of usc-hs21ti hall water flow sensor from iSentrol
Ce Report of usc-hs21ti hall water flow sensor from iSentrol
 
Ultisolar SR81Q Solar Controller Manual
Ultisolar SR81Q Solar Controller ManualUltisolar SR81Q Solar Controller Manual
Ultisolar SR81Q Solar Controller Manual
 
Ultisolar SR1568 Most Powerful Solar Thermal Controller Wifi Featured
Ultisolar SR1568 Most Powerful Solar Thermal Controller Wifi FeaturedUltisolar SR1568 Most Powerful Solar Thermal Controller Wifi Featured
Ultisolar SR1568 Most Powerful Solar Thermal Controller Wifi Featured
 
Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System
Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System
Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System
 
Ultisolar SR658 Solar Controller for Split Hot water system
Ultisolar SR658 Solar Controller for Split Hot water systemUltisolar SR658 Solar Controller for Split Hot water system
Ultisolar SR658 Solar Controller for Split Hot water system
 
Ultisolar SR288 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR288 Split Solar Thermal System Controller Wifi FeaturedUltisolar SR288 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR288 Split Solar Thermal System Controller Wifi Featured
 
Ultisolar SR258 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR258 Split Solar Thermal System Controller Wifi FeaturedUltisolar SR258 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR258 Split Solar Thermal System Controller Wifi Featured
 
SP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New ManualSP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New Manual
 
US211M定量控制仪产品使用说明书
US211M定量控制仪产品使用说明书US211M定量控制仪产品使用说明书
US211M定量控制仪产品使用说明书
 
US211M Quantitative Controller and Flow Rate Display User Manual
US211M Quantitative Controller and Flow Rate Display User ManualUS211M Quantitative Controller and Flow Rate Display User Manual
US211M Quantitative Controller and Flow Rate Display User Manual
 
SR805W Wireless Remote Controller User Manual
SR805W Wireless Remote Controller User ManualSR805W Wireless Remote Controller User Manual
SR805W Wireless Remote Controller User Manual
 
SR805 Remote Controller User Manual
SR805 Remote Controller User ManualSR805 Remote Controller User Manual
SR805 Remote Controller User Manual
 
Ultisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User Manual
Ultisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User ManualUltisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User Manual
Ultisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User Manual
 
Ultisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User Manual
Ultisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User ManualUltisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User Manual
Ultisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User Manual
 
Ultisolar LS1024BP LS2024BP Solar Controller user manual
Ultisolar  LS1024BP LS2024BP Solar Controller user manualUltisolar  LS1024BP LS2024BP Solar Controller user manual
Ultisolar LS1024BP LS2024BP Solar Controller user manual
 
SR528Q Wireless Solar Controller for Split Solar Water Heating System
SR528Q Wireless Solar Controller for Split Solar Water Heating SystemSR528Q Wireless Solar Controller for Split Solar Water Heating System
SR528Q Wireless Solar Controller for Split Solar Water Heating System
 
Usc-hs43tb Water Hall Flow Sensor Datasheet by Ultisensor
Usc-hs43tb Water Hall Flow Sensor Datasheet by UltisensorUsc-hs43tb Water Hall Flow Sensor Datasheet by Ultisensor
Usc-hs43tb Water Hall Flow Sensor Datasheet by Ultisensor
 
eTracer Network MPPT Solar Charge Controller ET2415N,ET3415N,ET4415N,ET6415N
eTracer Network MPPT Solar Charge Controller ET2415N,ET3415N,ET4415N,ET6415NeTracer Network MPPT Solar Charge Controller ET2415N,ET3415N,ET4415N,ET6415N
eTracer Network MPPT Solar Charge Controller ET2415N,ET3415N,ET4415N,ET6415N
 
USN-HS43TA ABS Hall Flow Sensor 1-60L/min from Ultisensor
USN-HS43TA ABS Hall Flow Sensor 1-60L/min from UltisensorUSN-HS43TA ABS Hall Flow Sensor 1-60L/min from Ultisensor
USN-HS43TA ABS Hall Flow Sensor 1-60L/min from Ultisensor
 

Último

FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756
dollysharma2066
 
Brand experience Dream Center Peoria Presentation.pdf
Brand experience Dream Center Peoria Presentation.pdfBrand experience Dream Center Peoria Presentation.pdf
Brand experience Dream Center Peoria Presentation.pdf
tbatkhuu1
 

Último (20)

Cash payment girl 9257726604 Hand ✋ to Hand over girl
Cash payment girl 9257726604 Hand ✋ to Hand over girlCash payment girl 9257726604 Hand ✋ to Hand over girl
Cash payment girl 9257726604 Hand ✋ to Hand over girl
 
Five Essential Tools for International SEO - Natalia Witczyk - SearchNorwich 15
Five Essential Tools for International SEO - Natalia Witczyk - SearchNorwich 15Five Essential Tools for International SEO - Natalia Witczyk - SearchNorwich 15
Five Essential Tools for International SEO - Natalia Witczyk - SearchNorwich 15
 
Situation Analysis | Management Company.
Situation Analysis | Management Company.Situation Analysis | Management Company.
Situation Analysis | Management Company.
 
Social media, ppt. Features, characteristics
Social media, ppt. Features, characteristicsSocial media, ppt. Features, characteristics
Social media, ppt. Features, characteristics
 
Factors-Influencing-Branding-Strategies.pptx
Factors-Influencing-Branding-Strategies.pptxFactors-Influencing-Branding-Strategies.pptx
Factors-Influencing-Branding-Strategies.pptx
 
FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu.Ka.Tilla Delhi Contact Us 8377877756
 
BDSM⚡Call Girls in Sector 144 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 144 Noida Escorts >༒8448380779 Escort ServiceBDSM⚡Call Girls in Sector 144 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 144 Noida Escorts >༒8448380779 Escort Service
 
The+State+of+Careers+In+Retention+Marketing-2.pdf
The+State+of+Careers+In+Retention+Marketing-2.pdfThe+State+of+Careers+In+Retention+Marketing-2.pdf
The+State+of+Careers+In+Retention+Marketing-2.pdf
 
Top 5 Breakthrough AI Innovations Elevating Content Creation and Personalizat...
Top 5 Breakthrough AI Innovations Elevating Content Creation and Personalizat...Top 5 Breakthrough AI Innovations Elevating Content Creation and Personalizat...
Top 5 Breakthrough AI Innovations Elevating Content Creation and Personalizat...
 
Foundation First - Why Your Website and Content Matters - David Pisarek
Foundation First - Why Your Website and Content Matters - David PisarekFoundation First - Why Your Website and Content Matters - David Pisarek
Foundation First - Why Your Website and Content Matters - David Pisarek
 
The Science of Landing Page Messaging.pdf
The Science of Landing Page Messaging.pdfThe Science of Landing Page Messaging.pdf
The Science of Landing Page Messaging.pdf
 
Major SEO Trends in 2024 - Banyanbrain Digital
Major SEO Trends in 2024 - Banyanbrain DigitalMajor SEO Trends in 2024 - Banyanbrain Digital
Major SEO Trends in 2024 - Banyanbrain Digital
 
Google 3rd-Party Cookie Deprecation [Update] + 5 Best Strategies
Google 3rd-Party Cookie Deprecation [Update] + 5 Best StrategiesGoogle 3rd-Party Cookie Deprecation [Update] + 5 Best Strategies
Google 3rd-Party Cookie Deprecation [Update] + 5 Best Strategies
 
BDSM⚡Call Girls in Sector 150 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 150 Noida Escorts >༒8448380779 Escort ServiceBDSM⚡Call Girls in Sector 150 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 150 Noida Escorts >༒8448380779 Escort Service
 
Brand experience Dream Center Peoria Presentation.pdf
Brand experience Dream Center Peoria Presentation.pdfBrand experience Dream Center Peoria Presentation.pdf
Brand experience Dream Center Peoria Presentation.pdf
 
Digital Strategy Master Class - Andrew Rupert
Digital Strategy Master Class - Andrew RupertDigital Strategy Master Class - Andrew Rupert
Digital Strategy Master Class - Andrew Rupert
 
Creator Influencer Strategy Master Class - Corinne Rose Guirgis
Creator Influencer Strategy Master Class - Corinne Rose GuirgisCreator Influencer Strategy Master Class - Corinne Rose Guirgis
Creator Influencer Strategy Master Class - Corinne Rose Guirgis
 
BLOOM_April2024. Balmer Lawrie Online Monthly Bulletin
BLOOM_April2024. Balmer Lawrie Online Monthly BulletinBLOOM_April2024. Balmer Lawrie Online Monthly Bulletin
BLOOM_April2024. Balmer Lawrie Online Monthly Bulletin
 
Generative AI Master Class - Generative AI, Unleash Creative Opportunity - Pe...
Generative AI Master Class - Generative AI, Unleash Creative Opportunity - Pe...Generative AI Master Class - Generative AI, Unleash Creative Opportunity - Pe...
Generative AI Master Class - Generative AI, Unleash Creative Opportunity - Pe...
 
Enjoy Night⚡Call Girls Dlf City Phase 4 Gurgaon >༒8448380779 Escort Service
Enjoy Night⚡Call Girls Dlf City Phase 4 Gurgaon >༒8448380779 Escort ServiceEnjoy Night⚡Call Girls Dlf City Phase 4 Gurgaon >༒8448380779 Escort Service
Enjoy Night⚡Call Girls Dlf City Phase 4 Gurgaon >༒8448380779 Escort Service
 

SPP-01 Super Parameter Programmer User Manual Ultisolar New Energy

  • 1. Make a better use of solar www.ul tisolar.com Super Parameter Programmer SPP-01 Dear user: Thank you very much for selecting our product! This manual offers important information and suggestions about use and troubleshooting, etc. Please read this manual carefully before using the product. Warranty: The product is warranted to be free from defects for a period of two years from the date of shipment to the original end user.
  • 2. Contents 1 Important Safety Information ............................................ 1 2 General Information ........................................................ 1 2.1 Product Characteristic ................................................... 1 2.2 Main Functions ............................................................ 2 2.3 Recommendation ......................................................... 2 3 Features ........................................................................ 3 3.1 Features...................................................................... 3 3.2 Power Supply and Startup .............................................. 5 4 Software Operation ......................................................... 7 4.1 Software Operating Environment..................................... 7 4.2 Software Installation and Uninstalling .............................. 7 4.3 Software Operating Instructions ...................................... 7 5 Specification ................................................................ 22 5.1 Hardware Configuration .............................................. 22 5.2 SPP-01 Parameter....................................................... 22 6 SPP-01 Overall Dimension ............................................. 23
  • 3. 1 1 Important Safety Information This manual contains important safety, setting and operating instructions for SPP-01. Save these instructions.  Please inspect the product thoroughly after it is delivered. If any damage is seen, please notify the shipping company or our company immediately.  Read of the instructions and cautions in the manual before using.  Keep the product away from rain, exposure, severe dust, vibrations, corrosive gas and intense electromagnetic interference.  Do not allow water to enter the controller.  Do not disassemble or attempt to repair it. 2 General Information 2.1 Product Characteristic Super parameter programmer (SPP-01) is the simple, efficient and practical accessory for parameter configuration with the easy one button operation. Due to the new standard communication protocol, it applies to stand-alone or multi-parallel products. The features of the SPP-01 are listed below.  One button and one indication led are designed for simplicity and easy-to-operate.  RS232 (TTL), RS485 and USB communication are supported.  SPPPCTools PC software is used to configure and backup parameters
  • 4. 2 visually, rapidly and conveniently.  Dual power supply design. SPP-01 can be powered by battery or Micro-USB cable applying for various environments. 2.2 Main Functions  Parameter configuration function Load the parameter configuration to the SPP-01 via SPPPCTools PC software and then update the device’s parameters through SPP-01 with easy one button.  Data transparent transmission function. SPP-01 can be used as the communication converter to connect the device and Solar Station Monitor, a PC software, to establish remote monitoring. 2.3 Recommendation DCCPxxxxDP (R), LSxxxxB (PL), VSxxxxB, TracerxxxxB (PL) and iTracerxxB series products are supported to update the configuration by SPP-01. Please confirm whether to support before purchasing.
  • 5. 3 3 Features 3.1 Features Description Operation Remarks K1(Toggle switch1) COM Communication converter mode MEM Parameter configuration mode K2(Toggle switch 2) Line Wire communication mode IrDA Reserved K3(Toggle switch 3) On Power on Off Power off K4(Water proof key 4) Press the button Press the key to enter configuration mode (the indicator led is on), click it again to update the configuration. Press and hold the button Test “Turn on” or “Turn off” the load. Indicator led and buzzer Configuration mode The indicator led is on without a beep. Update The indicator led flashes once K1 K2 K3 LED K4
  • 6. 4 successfully. with one short beep. Communication error The indicator led flashes twice with two short beeps. The model is not matched or the irrational configuration The indicator led flashes triple with three short beeps. Test The indicator light flashes for several times with one long beep. Note: 1. Press and hold the button for three seconds to alternately turn on or turn off the load in the testing mode. After 3 minutes, the device will quit the test mode automatically. 2. In the testing mode, the SPP-01 can switch the load no matter whether it has loaded the configuration or not. RJ11 RJ45
  • 7. 5 Description Operating Remarks RJ11 interface Connect the controller with the CC-TTL-TTL-150U communication cable Update device configure RJ45 interface Connect the controller with the CC-RS485- RS485-150U communication cable Update device configure USB interface Connect to the PC with the CC-USB-USB-150U communication cable Update SPP01 configure RTC battery holder Battery for real-time time clock Type: CR1220 Battery compartment 3 batteries Size AAA 3.2 Power Supply and Startup The SPP-01 is powered by following three methods: 1. Get power via the USB data cable from USB interface. RTC Battery Battery compartment USB interface
  • 8. 6 2. Get power via exclusive data cable from the device. 3. Get power from 3 batteries (size AAA). Starting SPP-01: The SPP-01 is powered on by toggling K3 switch to “ON” Operating status Phenomena Normal startup The green light flashes once with one beep. No data available in SPP-01 The green light flashes for several times with several beeps.
  • 9. 7 4 Software Operation 4.1 Software Operating Environment  Hardware Environment  A Pentium 4-compatible PC  At least 512Mbyte of RAM and 55Mbyte of free disk space  Software Operating Environment The recommended operating system is as follows:  Windows XP (32bit), Win7 (32bit/64bit), Win8 (32bit/64bit)  Installing component: Windows Installer3_1, DotNetFX40. 4.2 Software Installation and Uninstalling  Installing the software Open directory “SPPPCSoftwareV3.77”, and double click “setup.exe”, after the computer start carry on the software gearing.  Uninstalling the software Click the Start >Control Panel >Add or delete programs> SPP> Delete. 4.3 Software Operating Instructions  Get serial port number for SPP-01 1. Connect the device: Connect SPP-01 to the PC with the Micro-USB cable and turn K3 switch to “ON” position. The SPP-01 starts normally with indicator led flashing once and a short beep.
  • 10. 8 2. Install SPP-01 serial port driver: Open directory “SPP USB Driver” and run “Setup.bat” file to install the driver. 3. Right click “My computer > Property > Hardware > Device manager” to pop up a device manager window, seeing the figure below: Note: The serial port number selected in the figure above is the serial port number of SPP-01 (COM8).
  • 11. 9  Main interface Parameter configure: 1. Double click software icon to pop up configuration interface of SPP-01. 2. The software will automatically open the port after selected serial port of SPP-01(the button caption will change from “open port” to “close port”) 3. The following dialog box will be popped up automatically by clicking “SELECT” tag:
  • 12. 10 Double click to select device (the configuration content will be changed automatically). 4. Configure relevant parameters by clicking “Control Parameters”, “General Load”, “LED Load” in the frame of Parameter Configuration and “Time Sync” in the Management. After configuring parameters, click “OK” to quit and return to main interface (For the parameters without configuration, uncheck the box “ ”). 5. After configuration, click button to load configuration into SPP-01 device (a corresponding dialog box will be popped up to prompt whether loaded successfully or not). Reading parameter data If the configuration has been loaded to the SPP-0, click button to upload the configuration in SPP-01 to PC, and refresh the corresponding parameter configuration in “Parameter configuration” frame, such as Control Parameter, General Load or LED Load, Time Sync so as to view and modify the parameters. Data clearing If it is required to clear configuration in SPP-01, click button directly. Importing and exporting parameter configuration If it is required to backup parameter configuration, click
  • 13. 11 button to save the configuration as a text file with extension of .TXT. If it is required to import configuration backed up previously, click button to load corresponding TXT file to upload the configuration.  Control Parameter Battery type Battery type Notes Sealed (default) Fixed controlling voltage, unable to be modified Gel Fixed controlling voltage, unable to be modified Flooded Fixed controlling voltage, unable to be modified User Users can modify voltage controlling points.
  • 14. 12 Charging Mode Charging mode Notes Voltage compensation Voltage control charging (default) SOC Set the charge and discharge SOC target values for battery charge and discharge control Other Control Parameter Parameters Default Range Battery Ah 200Ah 1~9999Ah Temperature compensation coefficient -3mV/ºC/2V -9~-0mV Rated Voltage Auto Auto/12V/24V/36V/48V Battery charging 100% 100%(SOC Mode) Battery discharging 30% 10~80%(SOC Mode) Note: Battery charging voltage ≥ Battery discharge+10% or battery discharge value ≤ Battery charge-10% value Battery Voltage Parameters (values are in 12V system at 25ºC, please double in 24V, triple in 36 V, and quadruple in 48 V system) Battery type Sealed Gel Flooded User High Volt Disconnect 16V 16V 16V 9~17V Charging Limit Voltage 15V 15V 15V 9~17V Over Voltage Reconnect 15V 15V 15V 9~17V Equalize Charging —— 14.6V 14.8V 9~17V
  • 15. 13 Boost Charging Voltage 14.2V 14.4V 14.6V 9~17V Float Charging Voltage 13.8V 13.8V 13.8V 9~17V Boost Return Voltage 13.2V 13.2V 13.2V 9~17V Low Voltage Reconnect 12.6V 12.6V 12.6V 9~17V Under Voltage Recover 12.2V 12.2V 12.2V 9~17V Under Voltage Warning 12V 12V 12V 9~17V Low Voltage Disconnect Voltage 11.1V 11.1V 11.1V 9~17V Discharging Limit Voltage 10.6V 10.6V 10.6V 9~17V Equalize Duration —— 120 Min. 120 Min. 0~180 Min. Boost Duration 120 Min. 120 Min. 120 Min. 10~180 Min. Note: The following rules must be observed when modify the parameters value in user battery type (factory default value is the same as sealed type):  High Volt Disconnect > Charging limit voltage ≥ Equalization voltage ≥ Boost voltage ≥ Float voltage > Boost return voltage  High Volt Disconnect > Over Voltage Reconnect  Low Voltage Reconnect > Low Voltage Disconnect ≥ Discharging Limit Voltage  Under Voltage Warning Reconnect > Under Voltage Warning ≥ Discharging Limit Voltage  Boost Reconnect Charging voltage > Low Voltage Disconnect
  • 16. 14  Load Configuration Load Mode  Manual (load can be switched by manual button or remote control command) On by default Controller switches on the load output once initialized and keep constant output on condition that the battery is enough electricity and no abnormal situation.
  • 17. 15 Off by default Controller keep the load output off before, during and after initialized. The load can be switched on only when doing “Manual On by default” operation and the battery is enough electricity and no abnormal situation.  Time Control Time1(T1) Control on/off time1 of load through real-time clock mode. Time2(T2) Control on/off time2 of load in dual time mode.  Light ON/OFF Light ON Voltage When input voltage of solar module goes below light ON voltage, the solar controller will recognize the starting voltage and turn on the load after pre-set time delay when the battery power is enough and the controller works well. Light OFF Voltage When input voltage of solar module goes above light OFF voltage, the solar controller will recognize the starting voltage and turn off the load after pre-set time delay. Delay Time The confirmation time for Light signal. During the period, if light signal voltage continues matching Light ON/OFF voltage, it will carry out corresponding actions(The time adjustment range:0~99mins.
  • 18. 16  Light ON+ Timer Working Time 1(T1) Load working period after light control turns ON load Working Time 2(T2) Load working period before light control turns OFF load Night Time The controller calculated the total length of the night by self-learning. The time should be more than 3 hours Light Control +Time Model Diagram
  • 19. 17  LED Load Configuration  LED Load parameter Parameter Remark LED Rated Current Rated output current. LED Rated Current Percentage Set up the parameter of the rated current percentage of the corresponding operating period of the controller; the controller will control the LED load output current according to this value.
  • 20. 18 Battery Under Voltage Control When the battery is under this voltage, the output current will be half; when the voltage of the battery goes above it, the controller will resume the set current value automatically.  Manual Control(load can be switched by manual button or remote control command) Manually On By default Controller switches on the load output once initialized and keep constant output on condition that the battery is enough electricity and no abnormal situation. Manually Off By default Controller keep the load output off before, during and after initialized. The load can be switched on only when doing “Manual On by default” operation and the battery is enough electricity and no abnormal situation.  Time Control Time1(T1) Control on/off time1 of load through real-time clock mode. Time2(T2) Control on/off time2 of load in dual time mode.  Light ON/OFF Light ON Voltage When input voltage of solar module goes below light ON voltage, the solar controller will recognize the starting voltage and turn on the load after pre-set time delay when the battery power is enough and the controller works well.
  • 21. 19 Light OFF Voltage When input voltage of solar module goes above light OFF voltage, the solar controller will recognize the starting voltage and turn off the load after pre-set time delay. Delay Time The confirmation time for Light signal. During the period, if light signal voltage continues matching Light ON/OFF voltage, it will carry out corresponding actions(The time adjustment range:0~99mins.  Light Control +Time Model 1 Work Time1 (T1) Load working period after light control turns ON load. Work Time2 (T2) The running hour of the load after the end of the work time1. Work Time3 (T3) The running hour of the load after the end of the work time2. Light Control +Time1 Mode1 diagram
  • 22. 20  Light Control +Time Model 2 Work Time1 (T1) Load working period after light control turns ON load. Work Time2 (T2) The running hour of the load after the end of the work time 1. Work Time3(T3) Load working period before light control turns off load. Night Time The controller calculated the total length of the night by self-learning. The time should be more than 3 hours. Light Control +Time2 Model diagram
  • 23. 21  Time Synchronize Parameters Remarks PC time Display PC time by default; Edit the time by clicking “Manually”. SPP time Display real-time clock of SPP-01. The current PC time data can be directly update to SPP-01 by clicking “Update” button; click “Manually” button to edit the values; click “Read” button to get the time from SPP-01 and display in “SPP Time” text box.
  • 24. 22 5 Specification 5.1 Hardware Configuration Items Descriptions Indicator light 1 green LED indicator RTC clock The real-time clock will not be lost when the backup battery is installed. Please replace the batteries when the time of SPP-01 is not correct. Power supply From three AAA (7#) batteries; From Micro-USB cable via PC USB power; From exclusive data cable via the controller. Buzzer One built-in buzzer to prompt that communication is right or wrong. Communication port RJ11(TTL), RJ45(RS485), Micro-USB(USB). 5.2 SPP-01 Parameter Parameter Rated Power Supply Voltage 5.0V Static Current < 40 mA Communication Baud 115200bps Working temperature -25ºC~+55ºC Enclosure IP30 Overall dimension 109 mm *60 mm *33mm Net weight 80.1g
  • 25. 23 6 SPP-01 Overall Dimension
  • 26. Make a better use of solar www.ul tisolar.com
  • 27.
  • 28. info@ultisolar.com http://www.ultisolar.com http://shop.ultisolar.com Final interpretation right of the manual belongs to our company. Any changes without prior notice! Ver1.1