Intelligent load control for heated wind measurement sensors
1. Intelligent load control for heated wind measurement sensors
Intelligent load control for
heated wind measurement sensors
A. Krenn1, H. Winkelmeier1, F. Lachinger1
1Energiewerkstatt, Friedburg, Austria
Winterwind 2012, Skellefteå/SE
2. Intelligent load control for heated wind measurement sensors
Company Profile
Wind Energy
• Wind Measurement
• Project Development
• Planning & Implementation
• Training and Education
• Research & Demonstration
Winterwind 2012, Skellefteå/SE
3. Intelligent load control for heated wind measurement sensors
01 Wind Energy in Austria
02 Test Rig Schareck / Großglockner
03 Wind Measurement Brenner
Winterwind 2012, Skellefteå/SE
4. Intelligent load control for heated wind measurement sensors
Wind Energy in Austria
State 31.12.2011
• 650 Wind turbines
• 1.084 MW installed power
• 2,39 TWh electricity generation per year
• 3,6 % of Austrian electricity demand
Winterwind 2012, Skellefteå/SE
5. Intelligent load control for heated wind measurement sensors
Wind conditions in Austria
• •
•
3
•• •7
•
•4
V med••5,5 - 6,0 m/s
•• ••
••
•
•
••
••
4
•
•
4
• •• • •• • ••
•• • •
3
•
3
•• • • – ••
•• • V med •6,5 • 7,0 m/s
7
•• •
•• • • •
• ••
4
•
V med 5,5 – 6,5 m/s ••
5
10
•
•
3 •
•
V med 6,0 - 7,5 m/s
•
Winterwind 2012, Skellefteå/SE
6. Intelligent load control for heated wind measurement sensors
Specific wind energy production in Austria
Specific wind energy production in different regions of Austria
1200
Eastern Region (106 WT) Northern Region (14 WT) Pre-Alpine Region (23 WT) Alps (13 WT)
1000
800
[kWh/m²]
600
1042
1010
990
961
915
910
907
900
863
861
843
812
798
400
750
745
735
686
665
660
639
614
602
525
501
499
475
460
410
200
0
2003 2004 2005 2006 2007 2008 2009
Winterwind 2012, Skellefteå/SE
7. Intelligent load control for heated wind measurement sensors
01 Wind Energy in Austria
02 Test Rig Schareck / Großglockner
03 Wind Measurement Brenner
Winterwind 2012, Skellefteå/SE
8. Intelligent load control for heated wind measurement sensors
Test Rig Schareck
Winterwind 2012, Skellefteå/SE
9. Intelligent load control for heated wind measurement sensors
Measurement setup
Producer Type Operating
mode Power
[W]
NRG Ice
Free
3 Heated
cup
anemometer 96
W
Vaisala WAA252 Heated
cup
anemometer 72
W
Thies
A. 2D Heated
2D
Ultrasonic 310
W
Thies
A. 2D
Compact Heated
2D
Ultrasonic
compact 250
W
Thies
A. Classic Unheated
cup
anemometer -‐-‐-‐-‐-‐
Thies
A. Classic Wind
vane 25
W
Galltek P63-‐12 Combined
Thermo-‐/Hygrosensor -‐-‐-‐-‐-‐
Mobotix M12
Dual
Night Webcam
with
infrared
spotlight -‐-‐-‐-‐-‐
Winterwind 2012, Skellefteå/SE
10. Intelligent load control for heated wind measurement sensors
Data evaluation
Comparison of five different scenarios rsp. icing periods:
• Actual meteorological icing periods based on webcam evaluations
• Actual instrumental icing periods based on webcam evaluations
• Estimated icing periods according to synoptic considerations
• Estimated icing periods according to comparison of heated and
unheated anemometers
• Estimated icing periods according to standard algorithms of heated
wind measurement sensors
Winterwind 2012, Skellefteå/SE
13. Intelligent load control for heated wind measurement sensors
Resulting Energy Demand
Scenario
Solution
regarding
heating
control
Used
settings
Energy
Consumption
1
Standard
sensor
algorithm
≤
2°C
100%
2
Comparison
heated/unheated
sensor
∆vmed
>
2
m/s
29%
3
Relative
humidity
und
temperature
≥
90%;
≤ 1°C
55%
Winterwind 2012, Skellefteå/SE
14. Intelligent load control for heated wind measurement sensors
Considerations regarding heating demand
• Theoretically, heating of wind measurement sensors is only necessary
during meteorological icing periods
• In case of external power supply units
– Which energy consumption do we have?
– How much energy is available?
– Which data availability do I want to achieve?
• Importance of an advanced load control management
• Possible approaches:
– Info from webcam, difference betw. heated and unh. sensor not available
– Synoptic considerations (equivalent to meteorological icing)
• Overestimation of icing periods, but still ~ 50% saving of energy
– In future - ice detector: current obstacles (350 W heating demand, costs)
Winterwind 2012, Skellefteå/SE
15. Intelligent load control for heated wind measurement sensors
01 Wind Energy in Austria
02 Test Rig Schareck / Großglockner
03 Wind Measurement Brenner
Winterwind 2012, Skellefteå/SE
16. Intelligent load control for heated wind measurement sensors
Wind farm Brenner
• 2.100 – 2.200m above sea level
• 600 W/m2 at hub height (estimated)
• 40 days per year icing (estimated)
• 19 Wind turbines approved (LTW70 – 2.0 MW)
Wind Farm Brenner
Winterwind 2012, Skellefteå/SE
17. Intelligent load control for heated wind measurement sensors
Measurement concept
LI DAR 03 - Sattelberg
Windmessung Steinjoch - 50 m
LIDAR 01 - Steinjoch
LIDAR 02 - Kreuzjoch
Winterwind 2012, Skellefteå/SE
18. Intelligent load control for heated wind measurement sensors
Wind measurement mast Steinjoch
Energiewerkstatt offered:
50m Mast with heated ultrasonic anemometer
External power supply system; 97% data availability
Winterwind 2012, Skellefteå/SE
19. Intelligent load control for heated wind measurement sensors
External power supply system
Power demand Ultrasonic: 250 W (periodically)
Power demand LIDAR: 40 W (100 W) (continuously)
Technical specification:
PV generator: 4 x 180 W
Wind generator: 2,40 m diameter / 900 W
Fuel cell: 300 W (as backup)
Hydrogen store: 6 bottles à 50 litres
Battery storage: 600 Ah / c100
Data storage: Ammonit Meteo 32
Dimensions: 1.10 / 2.20 / 1.80
Operat. control: EMS Energy
management system
Winterwind 2012, Skellefteå/SE
20. Intelligent load control for heated wind measurement sensors
Energy management system
Controlling of the system
• Load management: Managing the
power demand of the sensors
according to the actual conditions
• Production management:
Intelligent interplay of the
components
• Thermal management: Intelligent
provision of the required thermal
conditions (for battery pack and fuel
cell)
• Provision of a remote control
system, which allows permanent
control and a remote changing of
the settings
Winterwind 2012, Skellefteå/SE
21. Intelligent load control for heated wind measurement sensors
Experience from first months
Extreme conditions
• Mean wind speed: 12 m/s in 23 m height
• Wind gusts (10min mean): > 30 m/s
• Ice accretion: Up to 8 cm (all-round)
Evaluation of 1 ½ months
• Surplus of ~30%
• No demand for FC (only self
consumption)
• Data availability of ~97%
Winterwind 2012, Skellefteå/SE
22. Intelligent load control for heated wind measurement sensors
Intelligent load control for
heated wind measurement sensors
Thanks for your attention!