Instruction Manual
LSVR:
Vibrating Rod Level
Switch for Solids
39 Mangal Nagar, Behind Sai Ram Plaza, Near Rajiv Gandhi
Circle, AB Road, Indore, MP 452 001, India
Phone: +91-731-497 2065
Trumen Technologies Pvt. Ltd. Customer Support
Phone: +91-731-656 2425
email: sales@trumen.in
email: support@trumen.in
web:www.trumen.in
®
sensing matters
List of content
Introduction - LSVR-UD (Order code EIUD / ERUD)...................................................
controls & indicators, connection terminals, configuration switches.........................
Electrical Connections - LSVR-UD (EIUD / ERUD).......................................................
Operating Principle.....................................................................................................................
Technical Specification................................................................................................................
Do's and Don'ts............................................................................................................................
Troubleshooting...........................................................................................................................
Maintenance & Spares...............................................................................................
Operation Matrix - LSVR-UD (EIUD / ERUD)...............................................................
1
Page1
2
3
4
4
Page
Annexure-1
Page1
Page2
Page3
Introduction - LSVR-DP (Order code EIDP / ERDP).....................................................
controls & indicators, connection terminals, configuration switches.........................
Electrical Connections - LSVR-DP (EIDP / ERDP).........................................................
Operation Matrix - LSVR-DP (EIDP / ERDP).................................................................
Page1
Annexure-2
Page1
Page2
Page3
Introduction - LSVR-U(S+P) (Order code EIUSP / ERUSP).........................................
controls & indicators, connection terminals, configuration switches.........................
Electrical Connections - LSVR-U(S+P) (EIUSP / ERUSP).............................................
Operation Matrix - LSVR-U(S+P) (EIUSP / ERUSP).....................................................
Page1
Annexure-3
Page1
Page2
Page3
Introduction - LSVR-AR (Order code EIAR)..................................................................
controls & indicators, connection terminals, configuration switches.........................
Electrical Connections - LSVR-AR (EIAR).....................................................................
Operation Matrix - LSVR-AR (EIAR).............................................................................
Page1
Annexure-4
Page1
Page2
Page3
Introduction - LSVR-DL (Order code EIDL)..................................................................
controls & indicators, connection terminals, configuration switches.........................
Electrical Connections - LSVR-DL (EIDL)......................................................................
Operation Matrix - LSVR-DL (EIDL)..............................................................................
Page1
Annexure-5
Page1
Page2
Page3
®
sensing matters
Operating Principle
LSVR Vibrating rod is a single element tuned mechanical element-type level sensing device.
When the material touches the rod, vibration stops as resonance gets disturbed.
Electronics of LSVR excites the piezo-electric-crystals inside the tuning rod, which makes
the rod vibrate at it's natural resonance frequency in free air.
Amplitudes of vibration are above threshold when the rod is free to vibrate.
Amplitude of vibration, as sensed by the electronics falls below the threshold, material presence is
thus detected by observing the amplitude of vibration.
lsvr-manual-page01 www.trumen.in 1
Technical Specification
Features Specifications
Applications
Specifications are subject to change without prior notice
1. Free flowing powders and granules
2. Suitable for side as well as top mounting
3. Minimum and maximum failsafe field selectable
4. Process temperature max 200°C
5. Process pressure max. 15 bar
Typical Mountings
1. Fast Switching Response
2. 1" screw mountings available
3. High pressure 15 bar
4. High Tempreture up-to 250°C available
5. Calibration-less operation
6. Remote electronics with std 10 meters cable length
7. Tropicalized & potted electronics module
8. Threaded & Flanged Mountings
9. Electronic Inserts support all requirements
10. Ingress protection : IP 68/66 (as per IS-13947)
11. Ex-proof (Ex d T6 IP-66 IIC )
- Flameproof as per IS/IEC 60079-1:2007
- Weatherproof (IP-66) as per IS/IEC 60529:2001
- Suitable for Gas Group : IIC
- Suitable for Zone 1 & 2 atmospheres
12. Compact size
13. Low power consumption (0.5 to 0.7 VA)
14. Settable switching delay as a standard feature
Integral / Remote Electronics
Universal Power Supply, DPDT Relay Output
15 to 80 VDC and 15 to 260 VAC 50/60Hz
Potential Free DPDT Relay Output
5 A each @ 24VDC or 220VAC
Integral / Remote Electronics for PNP Output
12 to 60 VDC, PNP
250mA max. Short Circuit Safe
Integral / Remote Electronics SPDT + PNP Output
Universal Supply for SPDT Output
15 to 80 VDC
15 to 260 VAC 50/60Hz
DC Supply for PNP Output
15 to 60 VDC
Potential Free DPDT Relay Output
5 A each @ 24VDC or 220VAC
250mA max. Short Circuit Safe
Integral Electronics AC series relay
Two Wire 18 to 260 VAC, Series Relay
not less than 4mA to release external relay
maximum 150mA to magnetize relay
Use relays/contactors will more than
4mA holding current
Integral Electronics 4-20mA Loop Powered
Two Wire DC 8 / 16 mA
15 to 60 VDC
8mA (±1mA max) / 16mA (±1mA max)
Remote electronics require special cable from rod to
controller.
10 meter standard length
more available on demand
>=350 gram/litre, not fluidized
-20°C ... 70°C (-4°F ... 158 °F)
-20°C ... 80°C (-4°F ... 176 °F)
-30°C ... 250°C (-22°F ... 482 °F)
(extensions & heat sinks required)
absolute / max. 15 bar
SS 316 or SS 316L
NPT / BSP 1", 1¼", 1½", 2" etc
Flanged : ANSI/JIS/DIN/ASA/custom
SS 304, SS 316, SS 316L
250mm to 3,000mm
0.5 VA max.
EIUD / ERUD
Supply & Output
Relay Type and Rating
EIDP / ERDP
Supply & Output
Output Limit
EIUSP / ERUSP
Supply & Output
Relay Type and Rating
EIAR
Supply & Output
Output Limit
EIDL
Supply & Output
Output Limit
Sensor Cable
Min. Density
Ambient Temp.
Process Temp.
Extended Process
Temperature
Process Pressure
Wetted Parts
Mountings
Extensions Tube
Material & Length
Power Consumption
lsvr-manual-page02 2
www.trumen.in
wall/pipe
mounting
remote
electronics
special
interconnection
cable
Features
Installation Precaution
Do's and Don'ts
1. Always connect the "Earth" to the external "Earthing" screw
2. Tighten the cable entries & glands properly
3. Secure the top aluminium cover at its place properly once the
electrical connections and other settings are completed
4. Always tighten the process connection using proper wrench
never try to tight by rotating the aluminium housing
5. Make sure process connection is same as that in hopper/tank
6. Vibrating rod probe:-
6.1 Should never be bent
6.2 Should never be held from thin part
6.3 Should never be cut or machined in any way
6.4 Should never be extended by welding or machining
7. Cable entries must face downwards only
8. Nozzles should never be longer than the rod sense
9. If mounted directly under the material entry, always install
a cannopy of suitable strength at proper height from the rod
10. Never climb either by gripping or stepping over either the
rod sense or its aluminium housing
11. Obeserve other safety precautions as required at the place
of application
3
2
4
5
1
6
6.2
lsvr-manual-page03 3
www.trumen.in
Troubleshooting
Maintenance and Spares
Top Cover
Electronic Insert
connection terminals
electronic insert fixing screw
4-way male connector for sensor (rod)
4-way female connector from sensor (rod)
Cable glands
Thermal spacer (where needed)
Process connection
Extension
Sense
Device enclosure
Shown on the left are various parts of LSVR level switch.
Separatable parts are
1. Electronic insert in short called 'electronics'
2. Rod + Enclosure + Cover + Glands collectively called 'mechanical'
For maintenance issues involving replacement of 'electronics', just a
single fixing screw is needed to be released.
Lift the electronics slowly by holding electronics with one hand and
mechanical with other, as wires are connected using rigid 4-way
connectors to it.
Disconnect 4-way connector by holding electronics with one hand and
female of connector by other hand, while the rest of the device is at rest.
Connect the new replaced sensor. 4-way connector is unidirectional
and only connects in proper direction.
Set the electronics properly to its position.
Match the mounting screw hole of electronics with that of enclosure
and fix the screw.
For mechanical issues please send the entire device back to Trumen.
Applications
Indication Probable cause Work-around Solution
No switching output or
sensor is permanently in alarm
If proper voltage is available but
'power' LED is still OFF
Power is not available
Sensor electronic insert internal power
section is failed
Sensor electronic insert rod oscillator
circuit failed
Sensor electronic insert evaluation
section failure
See if 'power' LED is ON
If power LED is OFF check voltage on
terminal 1 and 2
Sensor electronic insert is needed to be replaced.
Abrupt switching Material is agitated Set time delay to 5 second in both dry and
wet condition (turn switch 2, 3 ON)
Time delay solves switching issues in agitated
materials.
Device shows no material after some
time even when rod is inside the
material
Material fluffy or rod rate-holes the
material due to its own vibrations
Set device in sensitive mode (turn switch 1
ON)
Sensitive setting reduces vibrational strength and
makes switching point at lower amplitude.
Rod settings are all OK but rod fails to
switch to 'no material' at random times
Power supply carrying extra noise and
rod amplifier picking the noise
Make necessary arrangements to filter the
noise in power-line before being fed to the
device
Provide an exclusive earthing to terminal#
3, rod enclosure earthing screw and rod
process connection (device mounting
screw)
Device contains sufficient filtering of power supply
noise inside, but sometimes external earth is
needed to make filters sink the extra power supply
noise back to earth.
Device worked for few months / years
but now fails to switch with respect to
material while power conditions are all
same
Device senses rod frequency and
amplitude to ascertain presence /
absence of Material. Possible reasons
are
1. Rod frequency shift due to rod wear /
errosion by service material
2. Material deposition on rod leads
3. Over temperature of service material
causing rod drive damage
Select proper rod surface while ordering as
per service material to mitigate rod errosion
as well as deposition
Order device of proper thermal grade for
proper service life of device
Clean up deposited materials on rod
sense as a part of maintenance schedule
Care is needed to be taken while ordering.
Scheduled cleaning of rod sense in sticky material
application is recommended.
In case of temperature stress, rod sensor is needed
to be replaced.
Rod is not vibrating when rod sense
are touched by hand
Rod is vibrating but no switching output
when for rod sense are touched by
hand
Sensor electronic insert is needed to be replaced.
lsvr-manual-page04 4
www.trumen.in
1 sensitivity control
sensitive setting for low density materials
(turn-on for fluffy/low density powders etc)
(keep turned-off for normal density materials)
2 “dry” (or uncovered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod out of solid confirmation)
3 “wet” (or covered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod dipped in the material confirmation)
4 minimum failsafe select
Failsafe means alarm is same as power failure.
Turn on for underflow detection (min. failsafe)
Keep turned off for overflow detection
(max. failsafe)
configuration switches
OFF Position ON Position
Example of Switch in On and Off Positions
1 + of DC or Live of AC Supply input
2 - of DC or Neutral of AC Supply input
Supply:
15 to 80VDC or 15 to 260VAC 50/60Hz
3 Earth terminal for safety
4 Normally connected terminal of contact 1
5 Common terminal of contact 1
6 Normally open terminal of contact 1
7 Normally connected terminal of contact 2
8 Common terminal of contact 2
9 Normally open terminal of contact 2
A Alarm Indicating LED
B Configuration Switches
C Power ON LED Indicator
D Connecting Terminals
E External Earthing Terminal
controls & indicators
connection terminals
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-UD
5 sec
ON Position
OFF Position
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-UD
5 sec
status
power
L1 N
U 15... 80V DC
15... 260V AC
1 2 3 4 5 6 7 8 9
D
B
C
A
ON
E
lsvr-manual-annexure-1 www.trumen.in
Annexure-1
Introduction - LSVR-UD (EIUD / ERUD)
Page 1
Vibrating rod is a single element tuned mechanical element type level sensing device.
Failsafe defines that the alarm and power failure / device failure conditions are same to
the external system. Failsafe operation is best understood with the type of installation
and following matrix.
Off
Off
On
On
Failsafe
Setting
Material &
Installation
Status
LED Power ON
1 2 3 4
ON
min failsafe
1 2 3 4
ON
min failsafe
4 5 6 7 8 9
Material
Status
No material
at high level.
DPDT Relay Contacts
Power OFF
Switch no. 4
is off, failsafe
high/maximum.
Indicating
normal or
healthy
status.
4 5 6 7 8 9
Relay ON
normal or healthy
contacts.
Relay OFF
alarm contacts.
(due to power
failure)
No material
at low level.
Switch no. 4
is on, failsafe
low/minimum.
Indicating
alarm
status.
4 5 6 7 8 9
Relay OFF
alarm contacts.
4 5 6 7 8 9
1 2 3 4
ON
min failsafe Indicating
alarm
status.
4 5 6 7 8 9
Relay OFF
alarm contacts.
4 5 6 7 8 9
Relay OFF
alarm contacts.
(as it is)
Material is
above the low
level or rod is
covered with
material
1 2 3 4
ON
min failsafe
Switch no. 4
is on, failsafe
low/minimum.
4 5 6 7 8 9 4 5 6 7 8 9
Material is
above the high
level or rod is
covered with
material.
Indicating
normal or
healthy
status.
Relay ON
normal or healthy
contacts.
High
level
/
overflow
detection
Low
level
/
underflow
detection
lsvr-manual-annexure-1 www.trumen.in
Annexure-1
Operation Matrix - LSVR-UD (EIUD / ERUD)
Page 2
Switch no. 4
is off, failsafe
high/maximum.
Relay OFF
alarm contacts.
(as it is)
Relay OFF
alarm contacts.
(due to power
failure)
Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must.
electrical connections (AC)
lsvr-manual-annexure-1 www.trumen.in
electrical connections (DC)
DC
15 to 80 VDC
output
contact 1
output
contact 2
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-UD
status
power
L1 N
U 15... 80V DC
15... 260V AC
1 2 3 4 5 6 7 8 9
ON
output
contact 1
output
contact 2
Live
Neutral
15 to 260 VAC
50/60 Hz
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-UD
status
power
L1 N
U 15... 80V DC
15... 260V AC
1 2 3 4 5 6 7 8 9
ON
Electrical Connections - LSVR-UD (EIUD / ERUD)
Annexure-1
1 2 3
Red
White
Black
Page 3
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-UD
5 sec
status
power
L1 N
U 15... 80 VDC
15... 260 VAC
1 2 3 4 5 6 7 8 9
ON
Remote probe connections for LSVR-UD (ERUD)
1 sensitivity control
sensitive setting for low density materials
(turn-on for fluffy/low density powders etc)
(keep turned-off for normal density materials)
2 “dry” (or uncovered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod out of material confirmation)
3 “wet” (or covered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod dipped in the material confirmation)
4 minimum failsafe select
Failsafe means alarm is same as power failure.
Turn on for underflow detection (min. failsafe)
Keep turned off for overflow detection (max. failsafe)
configuration switches
OFF Position ON Position
Example of Switch in On and Off Positions
1 + of DC Supply input
2 - of DC Supply input
Supply:
12 to 60VDC
3 Earth terminal for safety
4 PNP output is supplied with voltage
12 to 60VDC
A Alarm Indicating LED
B Configuration Switches
C Power ON LED Indicator
D Connecting Terminals
E External Earthing Terminal
controls & indicators
connection terminals
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-DP
5 sec
ON Position
OFF Position
sensitive
dry delay
wet delay
min
failsafe
to set
turn-on
LSVR-DP
5 sec
status
power
U 12 to 60V DC
1 2 3 4 5 6 7 8 9
D
B
C
A
PNP (alarm=float)
ON
E
lsvr-manual-annexure-2 www.trumen.in
Annexure-2
Introduction - LSVR-DP (EIDP / ERDP)
Page 1
Vibrating rod is a single element tuned mechanical element type level sensing device.
Failsafe defines that the alarm and power failure / device failure conditions are same to
the external system. Failsafe operation is best understood with the type of installation
and following matrix.
Off
Off
On
On
Failsafe
Setting
Material &
Installation
Status
LED Power ON
1 2 3 4
ON
min failsafe
1 2 3 4
ON
min failsafe
Material
Status
No material
at high level.
PNP Output
Power OFF
Switch no. 4
is off, failsafe
high/maximum.
Indicating
normal or
healthy
status.
Normal or healthy
output.
Alarm output.
(due to power
failure)
No material
at low level.
Switch no. 4
is on, failsafe
low/minimum.
Indicating
alarm
status.
1 2 3 4
ON
min failsafe Indicating
alarm
status.
Material is
above the low
level or rod is
covered with
material.
1 2 3 4
ON
min failsafe
Material is
above the high
level or rod is
covered with
material.
Indicating
normal or
healthy
status.
High
level
/
overflow
detection
Low
level
/
underflow
detection
1 2 3 4
IL
IL(max) = 250mA Ileak ≤ 0.1mA
1 2 3 4
Ileak
Ileak ≤ 0.1mA
1 2 3 4
Ileak
Ileak ≤ 0.1mA
1 2 3 4
Ileak
Ileak ≤ 0.1mA
1 2 3 4
Ileak
Ileak ≤ 0.1mA
1 2 3 4
Ileak
1 2 3 4
IL
IL(max) = 250mA Ileak ≤ 0.1mA
1 2 3 4
Ileak
Alarm output.
(as it is)
Alarm output.
Alarm output.
(as it is)
Alarm output.
Normal or healthy
output.
lsvr-manual-annexure-2 www.trumen.in
Annexure-2
Operation Matrix - LSVR-DP (EIDP / ERDP)
Page 2
Alarm output.
(due to power
failure)
Switch no. 4
is off, failsafe
high/maximum.
Switch no. 4
is on, failsafe
low/minimum.
Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must.
lsvr-manual-annexure-2 www.trumen.in
electrical connections (DC)
sensitive
dry delay
wet delay
min
failsafe
to set
turn-on
LSVR-DP
5 sec
status
power
U 12 to 60V DC
1 2 3 4 5 6 7 8 9
PNP (alarm=float)
output unused terminals
DC
12 to 60 VDC
ON
Electrical Connections - LSVR-DP (EIDP / ERDP)
Annexure-2
1 2 3
Red
White
Black
sensitive
dry delay
wet delay
min
failsafe
to set
turn-on
LSVR-DP
5 sec
status
power
U 12 to 60V DC
1 2 3 4 5 6 7 8 9
PNP (alarm=float)
ON
Page 3
Remote probe connections for LSVR-DP (ERDP)
Introduction - LSVR-U(S+P) (EIUSP / ERUSP)
1 sensitivity control
sensitive setting for low density materials
(turn-on for fluffy/low density materials)
(keep turned-off for normal materials)
2 “dry” (or uncovered) delay (5 second delay)
(turn-on when 5 second more time is needed for
rod out of material confirmation)
3 “wet” (or covered) delay (5 second delay)
(turn-on when 5 second more time is needed for
rod dipped in the material confirmation)
4 minimum failsafe select
Failsafe means alarm is same as power failure.
Turn on for underflow detection (min. failsafe)
Keep turned off for overflow detection (max. failsafe)
configuration switches
OFF Position ON Position
Example of Switch in On and Off Positions
1 (+) of DC or Live of AC Supply input
2 (-) of DC or Neutral of AC Supply input
Supply:
15 to 80VDC or 15 to 260VAC 50/60Hz
3 Earth terminal for safety
4 Normally connected terminal of SPDT
contact
5 Common terminal of SPDT contact
6 Normally open terminal of SPDT contact
7 (-) of DC for PNP output
8 (+) of DC for PNP output
9 DC PNP output with respect to -ve of DC
Supply should be within 15 to 60VDC for
PNP output
A Alarm Indicating LED
B Configuration Switches
C Power ON LED Indicator
D Connecting Terminals
E External Earthing Terminal
controls & indicators
connection terminals
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-U(S+P)
5 Sec
ON Position
OFF Position
lsvr-manual-annexure-3 www.trumen.in Page 1
Annexure-3
!
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-U(S+P)
5 Sec
status
power
L1 N
U 15... 80V DC
15... 260V AC
1 2 3 4 5 6 7 8 9
D
B
C
A
E
ON
U
15... 60V DC
PNP o/p
!
less than
60VDC only
Failsafe defines that the alarm and power failure / device failure conditions are same to
the external system. Failsafe operation is best understood with the type of installation
and following matrix.
Operation Matrix - LSVR-U(S+P) (EIUSP / ERUSP)
lsvr-manual-annexure-3 www.trumen.in
Annexure-3
Page 2
Off
Off
On
On
Failsafe
Setting
Material &
Installation
Status
LED
1 2 3 4
ON
min failsafe
1 2 3 4
ON
min failsafe
Material
Status
No material
at high level.
Switch no. 4
is off, failsafe
high/maximum
Relay Contacts & PNP Output
Indicating
normal or
healthy
status.
Power ON Power OFF
1 2 3 4
ON
min failsafe
Switch no. 4
is off, failsafe
high/maximum
Material is
above the high
level or rod is
covered with
material.
Indicating
alarm
status.
No material
at low level.
Switch no. 4
is on, failsafe
low/minimum
Indicating
alarm
status.
Material is
above the low
level or rod is
covered with
material.
1 2 3 4
ON
min failsafe
Switch no. 4
is on, failsafe
low/minimum
Indicating
normal or
healthy
status.
High
level
/
overflow
detection
Low
level
/
underflow
detection
4 5 6 4 5 6
Relay ON normal
or healthy contacts.
Relay OFF alarm
contacts. (due to
power failure)
Relay OFF alarm
contacts.
Relay OFF alarm
contacts. (as it is)
Ileak ≤ 0.1mA
7 8 9
Ileak
7 8 9
IL
IL(max) = 250mA
7 8 9
Ileak
Ileak ≤ 0.1mA
7 8 9
Ileak
Ileak ≤ 0.1mA
7 8 9
Ileak
Ileak ≤ 0.1mA
7 8 9
Ileak
Ileak ≤ 0.1mA
4 5 6
4 5 6
Relay OFF alarm
contacts.
Relay OFF alarm
contacts. (as it is)
4 5 6
4 5 6
4 5 6 4 5 6
Relay ON normal
or healthy contacts.
Relay OFF alarm
contacts. (due to
power failure)
Ileak ≤ 0.1mA
7 8 9
Ileak
7 8 9
IL
IL(max) = 250mA
Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must.
lsvr-manual-annexure-3 www.trumen.in
Electrical Connections - LSVR-U(S+P) (EIUSP / ERUSP)
Annexure-3
1 2 3
Red
White
Black
Page 3
output
contact
Live
Neutral
15 to 260 VAC
50/60 Hz
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-U(S+P)
5 Sec
status
power
L1 N
U 15... 80V DC
15... 260V AC
1 2 3 4 5 6 7 8 9
ON
U
15... 60V DC
PNP o/p
!
less than
60VDC only
PNP
output DC
15 to 60 VDC
output
contact
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-U(S+P)
5 Sec
status
power
L1 N
U 15... 80V DC
15... 260V AC
1 2 3 4 5 6 7 8 9
ON
U
15... 60V DC
PNP o/p
!
less than
60VDC only
PNP
output
electrical connections (AC) electrical connections (DC)
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-U(S+P)
5 Sec
status
power
L1 N
U 15... 80V DC
15... 260V AC
1 2 3 4 5 6 7 8 9
ON
U
15... 60V DC
PNP o/p
!
less than
60VDC only
Remote probe connections for LSVR-U(S+P) (ERUSP)
1 Not used
2 “dry” (or uncovered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod out of material confirmation)
3 “wet” (or covered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod dipped in the material confirmation)
4 minimum failsafe select
Failsafe means alarm is same as power failure.
Turn on for underflow detection (min. failsafe)
Keep turned off for overflow detection (max. failsafe)
configuration switches
OFF Position ON Position
Example of Switch in On and Off Positions
1 Live of AC Supply through fuse
2 Neutral of AC Supply input through
specified series relay
18 to 260VAC 50/60 Hz series
3 Earth terminal for safety
4,5,6,7,8,9 Not used
A Alarm Indicating LED
B Configuration Switches
C Normal LED Indicator
D Connecting Terminals
E External Earthing Terminal
controls & indicators
connection terminals
x
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-AR
5 sec
ON Position
OFF Position
lsvr-manual-annexure-4 www.trumen.in
Annexure-4
Introduction - LSVR-AR (EIAR)
Page 1
x
dry delay
wet delay
to set
turn-on
LSVR-AR
5 sec
alarm
normal
U 18... 260V AC
1 2 3 4 5 6 7 8 9
D
B
C
A
E
ON
min failsafe
2 wire AC series Relay
(<5mA holding current)
Series relay will be energized in normal or healthy condition. Series relay will be de-
energized in alarm condition. Failsafe defines that the alarm and power failure / device
failure conditions are same to the external system. Failsafe operation is best understood
with the type of installation and following matrix.
Normal
or
healthy
Off
Alarm
Alarm
On
Failsafe
Setting
Material &
Installation
Status
LED
1 2 3 4
ON
min failsafe
1 2 3 4
ON
min failsafe
Switching
Operation
When switch no. 4
is off (failsafe high /
maximum).
output status shows
normal when there
is no material at high
switch point or rod
is out of the material.
When switch no. 4
is off (failsafe high /
maximum).
output status shows
alarm if rod is
dipped in material at
high switch point.
When switch no. 4
is on (failsafe low /
minimum).
output status shows
alarm when there is
no material at low
switch point or rod
is out of the material.
When switch no. 4
is on (failsafe low /
minimum).
output status shows
normal if rod is
dipped in material at
low switch point.
Series Relay Status
Alarm/
Normal
lsvr-manual-annexure-4 www.trumen.in Page 2
Annexure-4
Operation Matrix - LSVR-AR (EIAR)
High
level
/
overflow
detection
Low
level
/
underflow
detection
Power ON Power OFF
1 2 3 4
ON
min failsafe
Series relay
on
Series relay
off (due to
power
failure)
Red
Green
On
Red
Off
Green
1 2 3 4
ON
min failsafe
Normal
or
healthy
Off
On
Red
Green
On
Red
Off
Green
Series relay
off
Series relay
off
(as it is)
Series relay
off
Series relay
off
(as it is)
Series relay
on
Series relay
off (due to
power
failure)
1 2
L N
1 2
L N
1 2
L N
1 2
L N
1 2
L N
1 2
L N
1 2
L N
1 2
L N
Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must.
lsvr-manual-annexure-4 www.trumen.in
Annexure-4
Electrical Connections - LSVR-AR (EIAR)
electrical connections (AC)
Page 3
x
dry delay
wet delay
to set
turn-on
LSVR-AR
5 sec
alarm
normal
U 18... 260V AC
1 2 3 4 5 6 7 8 9
ON
min failsafe
2 wire AC series Relay
(<5mA holding current)
x
dry delay
wet delay
to set
turn-on
LSVR-AR
5 sec
alarm
normal
U 18... 260V AC
1 2 3 4 5 6 7 8 9
ON
min failsafe
2 wire AC series Relay
(<5mA holding current)
Not Used
L
N
AC Supply
18 to 260 VAC
Specified AC Series Relay
Use AC relay / contactor having maximum 150mA to
magnetize and holding current should not be less than 4mA.
Voltage rating of AC relay should be as per input supply voltage.
1 sensitivity control
sensitive setting for low density materials
(turn-on for fluffy / low density materials etc.)
(keep turned-off for normal density materials)
2 “dry” (or uncovered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod out of material confirmation)
3 “wet” (or covered) delay (5 second delay) setting
(turn-on when 5 second more time is needed for
rod dipped in the material confirmation)
4 minimum failsafe select
Failsafe means alarm is same as power failure.
Turn on for underflow detection (min. failsafe)
Keep turned off for overflow detection (max. failsafe)
configuration switches
OFF Position ON Position
Example of Switch in On and Off Positions
1 (+) of DC Supply input
2 (-) of DC Supply input
DC Supply: 12 to 60VDC
3 Earth terminal for safety
4,5,6,7,8,9 Not used
A Alarm Indicating LED
B Configuration Switches
C Power ON LED Indicator
D Connecting Terminals
E External Earthing Terminal
controls & indicators
connection terminals
sensitive
dry delay
wet delay
min failsafe
to set
turn-on
LSVR-DL-8/16
5 sec
ON Position
OFF Position
lsvr-manual-annexure-5 www.trumen.in
Annexure-5
Introduction - LSVR-DL (EIDL)
8/16 mA Output
Page 1
sensitive
dry delay
wet delay
min
failsafe
to set
turn-on
LSVR-DL-8/16
5 sec
alarm
power
U 12 to 60V DC
1 2 3 4 5 6 7 8 9
D
B
C
A
E
ON
Loop powered
8mA ± 1mA (alarm)
16mA ± 1mA (normal)
Miliampere output 16 is supplied in normal or healthy condition. Miliampere output 8
is supplied in alarm condition. Failsafe defines that the alarm and power failure /
device failure conditions are same to the external system. Failsafe operation is best
understood with the type of installation and following matrix.
Normal
Off
Off
Alarm
On
On
Failsafe
Setting
Material &
Installation
Status
LED
1 2 3 4
ON
min failsafe
1 2 3 4
ON
min failsafe
Switching
Operation
When switch no. 4
is off (failsafe high /
maximum).
output status shows
normal when there
is no material at high
switch point or rod
is out of the material.
When switch no. 4
is off (failsafe high /
maximum).
output status shows
alarm if rod is
dipped in material
at high switch point.
When switch no. 4
is on (failsafe low /
minimum).
output status shows
alarm when there is
no material at low
switch point or rod
is out of the material.
When switch no. 4
is on (failsafe low /
minimum).
output status shows
normal if rod is
dipped in material
at low switch point.
Miliampere Output
Status
lsvr-manual-annexure-5 www.trumen.in Page 2
Annexure-5
Operation Matrix - LSVR-DL (EIDL)
High
level
/
overflow
detection
Low
level
/
underflow
detection
1 2 3 4
ON
min failsafe
1 2 3 4
ON
min failsafe
1 2
DC
IL IL
IL = 16mA
1 2
DC
IL IL
IL = 8mA
1 2
DC
IL IL
IL = 8mA
1 2
DC
IL IL
IL = 16mA
Normal
Alarm
Electrical Connections - LSVR-DL (EIDL)
Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must.
electrical connections (DC)
lsvr-manual-annexure-5 www.trumen.in Page 3
Annexure-5
Not used
1 2 3 4 5 6 7 8 9
sensitive
dry delay
wet delay
min
failsafe
to set
turn-on
LSVR-DL-8/16
5 sec
alarm
power
U 12 to 60V DC
ON
Loop powered
8mA ± 1mA (alarm)
16mA ± 1mA (normal)
sensitive
dry delay
wet delay
min
failsafe
to set
turn-on
LSVR-DL-8/16
5 sec
alarm
power
U 12 to 60V DC
1 2 3 4 5 6 7 8 9
ON
Loop powered
8mA ± 1mA (alarm)
16mA ± 1mA (normal)
Supply
12 to 60 VDC
mA
Meter/Indicator/PLC/SCADA

Mais conteúdo relacionado

Semelhante a Vibrating Rod Point Level Switch for Solids India

I s7 eng_101201
I s7 eng_101201I s7 eng_101201
I s7 eng_101201Chan Suk
 
Hướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tầnHướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tầnHồng Trọng
 
67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 smtecxel
 
V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08Cara Bereck Levy
 
Catalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.com
Catalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.comCatalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.com
Catalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.comBeeteco
 
Catalog FR-D700 instruction manual (basic)-Beeteco.com
Catalog FR-D700 instruction manual (basic)-Beeteco.comCatalog FR-D700 instruction manual (basic)-Beeteco.com
Catalog FR-D700 instruction manual (basic)-Beeteco.comBeeteco
 
Mitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailedMitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailedawatori
 
Fuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manualFuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manualToàn Huỳnh
 
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetDrager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Manual osciloscopio GDS-800
Manual osciloscopio GDS-800Manual osciloscopio GDS-800
Manual osciloscopio GDS-800Armando Uribe Jr
 
Extech EX330 Mini Multimeter User Manual
Extech EX330 Mini Multimeter User ManualExtech EX330 Mini Multimeter User Manual
Extech EX330 Mini Multimeter User ManualTim Miller
 
I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131lenguyen277
 
K49 Controller
K49 ControllerK49 Controller
K49 ControllerJoseph
 

Semelhante a Vibrating Rod Point Level Switch for Solids India (20)

Magnetic Flowmeter Selection Model Zero Instrument.pdf
Magnetic Flowmeter Selection Model Zero Instrument.pdfMagnetic Flowmeter Selection Model Zero Instrument.pdf
Magnetic Flowmeter Selection Model Zero Instrument.pdf
 
I s7 eng_101201
I s7 eng_101201I s7 eng_101201
I s7 eng_101201
 
I s7 eng_101201
I s7 eng_101201I s7 eng_101201
I s7 eng_101201
 
Hướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tầnHướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tần
 
67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm
 
V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08V350-35-RA22_INSTAL-GUIDE_10-08
V350-35-RA22_INSTAL-GUIDE_10-08
 
Catalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.com
Catalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.comCatalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.com
Catalog Inverter FR-E700 instruction manual (basic) Mitsubishi-Beeteco.com
 
Catalog FR-D700 instruction manual (basic)-Beeteco.com
Catalog FR-D700 instruction manual (basic)-Beeteco.comCatalog FR-D700 instruction manual (basic)-Beeteco.com
Catalog FR-D700 instruction manual (basic)-Beeteco.com
 
Mitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailedMitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailed
 
Catalog biến tần Inovance MD310
Catalog biến tần Inovance MD310Catalog biến tần Inovance MD310
Catalog biến tần Inovance MD310
 
MAN0824-01
MAN0824-01MAN0824-01
MAN0824-01
 
Vfd l m-en_20030522
Vfd l m-en_20030522Vfd l m-en_20030522
Vfd l m-en_20030522
 
Fuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manualFuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manual
 
Fvr e11 manual
Fvr e11 manualFvr e11 manual
Fvr e11 manual
 
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetDrager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
 
Manual osciloscopio GDS-800
Manual osciloscopio GDS-800Manual osciloscopio GDS-800
Manual osciloscopio GDS-800
 
Extech EX330 Mini Multimeter User Manual
Extech EX330 Mini Multimeter User ManualExtech EX330 Mini Multimeter User Manual
Extech EX330 Mini Multimeter User Manual
 
I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131
 
Ex rc1 spec-en_1215
Ex rc1 spec-en_1215Ex rc1 spec-en_1215
Ex rc1 spec-en_1215
 
K49 Controller
K49 ControllerK49 Controller
K49 Controller
 

Mais de Trumen Technologies Pvt. Ltd. India

Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...
Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...
Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...Trumen Technologies Pvt. Ltd. India
 
Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...
Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...
Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...Trumen Technologies Pvt. Ltd. India
 
Trumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in India
Trumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in IndiaTrumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in India
Trumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in IndiaTrumen Technologies Pvt. Ltd. India
 

Mais de Trumen Technologies Pvt. Ltd. India (16)

Vibrating Rod Level Switch for Solids.pdf
Vibrating Rod Level Switch for Solids.pdfVibrating Rod Level Switch for Solids.pdf
Vibrating Rod Level Switch for Solids.pdf
 
Frequency Sweep Level Switch LMFS.pdf
Frequency Sweep Level Switch LMFS.pdfFrequency Sweep Level Switch LMFS.pdf
Frequency Sweep Level Switch LMFS.pdf
 
Flush Diaphragm Pressure Transmitter in India.pdf
Flush Diaphragm Pressure Transmitter in India.pdfFlush Diaphragm Pressure Transmitter in India.pdf
Flush Diaphragm Pressure Transmitter in India.pdf
 
Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...
Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...
Capacitance Head Level Sensor Type Rate of Flow Calculator, Indicator, Contro...
 
Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...
Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...
Capacitance Head Level Sensor Type Loss of Head Indicator, Controller, and Tr...
 
Instruction-Manual-ICT India.pdf
Instruction-Manual-ICT India.pdfInstruction-Manual-ICT India.pdf
Instruction-Manual-ICT India.pdf
 
Indicator Controller Cum Transmitter.pdf
Indicator Controller Cum Transmitter.pdfIndicator Controller Cum Transmitter.pdf
Indicator Controller Cum Transmitter.pdf
 
Vibrating Rod Point Level Switch for Solids
Vibrating Rod Point Level Switch for SolidsVibrating Rod Point Level Switch for Solids
Vibrating Rod Point Level Switch for Solids
 
Vibrating Rod Level Switch | Trumen Technologies Pvt Ltd
Vibrating Rod Level Switch | Trumen Technologies Pvt LtdVibrating Rod Level Switch | Trumen Technologies Pvt Ltd
Vibrating Rod Level Switch | Trumen Technologies Pvt Ltd
 
Vibrating Fork Level Switch | Trumen Technologies Pvt Ltd
Vibrating Fork Level Switch | Trumen Technologies Pvt LtdVibrating Fork Level Switch | Trumen Technologies Pvt Ltd
Vibrating Fork Level Switch | Trumen Technologies Pvt Ltd
 
Ultrasonic Level Transmitter
Ultrasonic Level TransmitterUltrasonic Level Transmitter
Ultrasonic Level Transmitter
 
Rotating Paddle Level Switch for Solids & Powders
Rotating Paddle Level Switch for Solids & PowdersRotating Paddle Level Switch for Solids & Powders
Rotating Paddle Level Switch for Solids & Powders
 
Capacitance Type Level Switch Manufacturers in Indiia
Capacitance Type Level Switch Manufacturers in IndiiaCapacitance Type Level Switch Manufacturers in Indiia
Capacitance Type Level Switch Manufacturers in Indiia
 
Capacitance Continuous Level Transmitter.pdf
Capacitance Continuous Level Transmitter.pdfCapacitance Continuous Level Transmitter.pdf
Capacitance Continuous Level Transmitter.pdf
 
Trumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in India
Trumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in IndiaTrumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in India
Trumen Vibrating Rod Point Level Switch Supplier Manufacturer Exporter in India
 
Trumen vibrating fork point level switch in India | LFV
Trumen vibrating fork point level switch in India | LFV Trumen vibrating fork point level switch in India | LFV
Trumen vibrating fork point level switch in India | LFV
 

Último

一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理
一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理
一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理bd2c5966a56d
 
如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一
如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一
如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一opyff
 
Why Does My Porsche Cayenne's Exhaust Sound So Loud
Why Does My Porsche Cayenne's Exhaust Sound So LoudWhy Does My Porsche Cayenne's Exhaust Sound So Loud
Why Does My Porsche Cayenne's Exhaust Sound So LoudRoyalty Auto Service
 
Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...
Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...
Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...gajnagarg
 
一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理
一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理
一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理ezgenuh
 
Is Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's Why
Is Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's WhyIs Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's Why
Is Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's WhyBavarium Autoworks
 
Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...
Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...
Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...Hyderabad Escorts Agency
 
Muslim Call Girls Churchgate WhatsApp +91-9930687706, Best Service
Muslim Call Girls Churchgate WhatsApp +91-9930687706, Best ServiceMuslim Call Girls Churchgate WhatsApp +91-9930687706, Best Service
Muslim Call Girls Churchgate WhatsApp +91-9930687706, Best Servicemeghakumariji156
 
Vip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime Begusarai
Vip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime BegusaraiVip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime Begusarai
Vip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime Begusaraimeghakumariji156
 
SEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVE
SEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVESEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVE
SEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVEZhandosBuzheyev
 
+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}
+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}
+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}Health
 
在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一
在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一
在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一qh1ao5mm
 
Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...gajnagarg
 
❤️Panchkula Enjoy 24/7 Escort Service sdf
❤️Panchkula Enjoy 24/7 Escort Service sdf❤️Panchkula Enjoy 24/7 Escort Service sdf
❤️Panchkula Enjoy 24/7 Escort Service sdfvershagrag
 
Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...nirzagarg
 
如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一
如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一
如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一avy6anjnd
 
John deere 7200r 7230R 7260R Problems Repair Manual
John deere 7200r 7230R 7260R Problems Repair ManualJohn deere 7200r 7230R 7260R Problems Repair Manual
John deere 7200r 7230R 7260R Problems Repair ManualExcavator
 
Changodar Call Girls Book Now 7737669865 Top Class Escort Service Available
Changodar Call Girls Book Now 7737669865 Top Class Escort Service AvailableChangodar Call Girls Book Now 7737669865 Top Class Escort Service Available
Changodar Call Girls Book Now 7737669865 Top Class Escort Service Availablegargpaaro
 
Is Your BMW PDC Malfunctioning Discover How to Easily Reset It
Is Your BMW PDC Malfunctioning Discover How to Easily Reset ItIs Your BMW PDC Malfunctioning Discover How to Easily Reset It
Is Your BMW PDC Malfunctioning Discover How to Easily Reset ItEuroService Automotive
 
一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证
一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证
一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证62qaf0hi
 

Último (20)

一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理
一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理
一比一原版(Greenwich毕业证书)格林威治大学毕业证如何办理
 
如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一
如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一
如何办理多伦多大学毕业证(UofT毕业证书)成绩单原版一比一
 
Why Does My Porsche Cayenne's Exhaust Sound So Loud
Why Does My Porsche Cayenne's Exhaust Sound So LoudWhy Does My Porsche Cayenne's Exhaust Sound So Loud
Why Does My Porsche Cayenne's Exhaust Sound So Loud
 
Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...
Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...
Top profile Call Girls In dewas [ 7014168258 ] Call Me For Genuine Models We ...
 
一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理
一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理
一比一原版(PU学位证书)普渡大学毕业证学历认证加急办理
 
Is Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's Why
Is Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's WhyIs Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's Why
Is Your Volvo XC90 Displaying Anti-Skid Service Required Alert Here's Why
 
Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...
Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...
Housewife Call Girl in Faridabad ₹7.5k Pick Up & Drop With Cash Payment #8168...
 
Muslim Call Girls Churchgate WhatsApp +91-9930687706, Best Service
Muslim Call Girls Churchgate WhatsApp +91-9930687706, Best ServiceMuslim Call Girls Churchgate WhatsApp +91-9930687706, Best Service
Muslim Call Girls Churchgate WhatsApp +91-9930687706, Best Service
 
Vip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime Begusarai
Vip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime BegusaraiVip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime Begusarai
Vip Begusarai Escorts Service Girl ^ 9332606886, WhatsApp Anytime Begusarai
 
SEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVE
SEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVESEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVE
SEM 922 MOTOR GRADER PARTS LIST, ALL WHEEL DRIVE
 
+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}
+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}
+97470301568>>buy vape oil,thc oil weed,hash and cannabis oil in qatar doha}}
 
在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一
在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一
在线定制(UBC毕业证书)英属哥伦比亚大学毕业证成绩单留信学历认证原版一比一
 
Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Mangalore [ 7014168258 ] Call Me For Genuine Models...
 
❤️Panchkula Enjoy 24/7 Escort Service sdf
❤️Panchkula Enjoy 24/7 Escort Service sdf❤️Panchkula Enjoy 24/7 Escort Service sdf
❤️Panchkula Enjoy 24/7 Escort Service sdf
 
Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...
Top profile Call Girls In Darbhanga [ 7014168258 ] Call Me For Genuine Models...
 
如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一
如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一
如何办理(NCL毕业证书)纽卡斯尔大学毕业证毕业证成绩单原版一比一
 
John deere 7200r 7230R 7260R Problems Repair Manual
John deere 7200r 7230R 7260R Problems Repair ManualJohn deere 7200r 7230R 7260R Problems Repair Manual
John deere 7200r 7230R 7260R Problems Repair Manual
 
Changodar Call Girls Book Now 7737669865 Top Class Escort Service Available
Changodar Call Girls Book Now 7737669865 Top Class Escort Service AvailableChangodar Call Girls Book Now 7737669865 Top Class Escort Service Available
Changodar Call Girls Book Now 7737669865 Top Class Escort Service Available
 
Is Your BMW PDC Malfunctioning Discover How to Easily Reset It
Is Your BMW PDC Malfunctioning Discover How to Easily Reset ItIs Your BMW PDC Malfunctioning Discover How to Easily Reset It
Is Your BMW PDC Malfunctioning Discover How to Easily Reset It
 
一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证
一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证
一比一原版(Deakin毕业证书)迪肯大学毕业证成绩单留信学历认证
 

Vibrating Rod Point Level Switch for Solids India

  • 1. Instruction Manual LSVR: Vibrating Rod Level Switch for Solids 39 Mangal Nagar, Behind Sai Ram Plaza, Near Rajiv Gandhi Circle, AB Road, Indore, MP 452 001, India Phone: +91-731-497 2065 Trumen Technologies Pvt. Ltd. Customer Support Phone: +91-731-656 2425 email: sales@trumen.in email: support@trumen.in web:www.trumen.in ® sensing matters
  • 2. List of content Introduction - LSVR-UD (Order code EIUD / ERUD)................................................... controls & indicators, connection terminals, configuration switches......................... Electrical Connections - LSVR-UD (EIUD / ERUD)....................................................... Operating Principle..................................................................................................................... Technical Specification................................................................................................................ Do's and Don'ts............................................................................................................................ Troubleshooting........................................................................................................................... Maintenance & Spares............................................................................................... Operation Matrix - LSVR-UD (EIUD / ERUD)............................................................... 1 Page1 2 3 4 4 Page Annexure-1 Page1 Page2 Page3 Introduction - LSVR-DP (Order code EIDP / ERDP)..................................................... controls & indicators, connection terminals, configuration switches......................... Electrical Connections - LSVR-DP (EIDP / ERDP)......................................................... Operation Matrix - LSVR-DP (EIDP / ERDP)................................................................. Page1 Annexure-2 Page1 Page2 Page3 Introduction - LSVR-U(S+P) (Order code EIUSP / ERUSP)......................................... controls & indicators, connection terminals, configuration switches......................... Electrical Connections - LSVR-U(S+P) (EIUSP / ERUSP)............................................. Operation Matrix - LSVR-U(S+P) (EIUSP / ERUSP)..................................................... Page1 Annexure-3 Page1 Page2 Page3 Introduction - LSVR-AR (Order code EIAR).................................................................. controls & indicators, connection terminals, configuration switches......................... Electrical Connections - LSVR-AR (EIAR)..................................................................... Operation Matrix - LSVR-AR (EIAR)............................................................................. Page1 Annexure-4 Page1 Page2 Page3 Introduction - LSVR-DL (Order code EIDL).................................................................. controls & indicators, connection terminals, configuration switches......................... Electrical Connections - LSVR-DL (EIDL)...................................................................... Operation Matrix - LSVR-DL (EIDL).............................................................................. Page1 Annexure-5 Page1 Page2 Page3 ® sensing matters
  • 3. Operating Principle LSVR Vibrating rod is a single element tuned mechanical element-type level sensing device. When the material touches the rod, vibration stops as resonance gets disturbed. Electronics of LSVR excites the piezo-electric-crystals inside the tuning rod, which makes the rod vibrate at it's natural resonance frequency in free air. Amplitudes of vibration are above threshold when the rod is free to vibrate. Amplitude of vibration, as sensed by the electronics falls below the threshold, material presence is thus detected by observing the amplitude of vibration. lsvr-manual-page01 www.trumen.in 1
  • 4. Technical Specification Features Specifications Applications Specifications are subject to change without prior notice 1. Free flowing powders and granules 2. Suitable for side as well as top mounting 3. Minimum and maximum failsafe field selectable 4. Process temperature max 200°C 5. Process pressure max. 15 bar Typical Mountings 1. Fast Switching Response 2. 1" screw mountings available 3. High pressure 15 bar 4. High Tempreture up-to 250°C available 5. Calibration-less operation 6. Remote electronics with std 10 meters cable length 7. Tropicalized & potted electronics module 8. Threaded & Flanged Mountings 9. Electronic Inserts support all requirements 10. Ingress protection : IP 68/66 (as per IS-13947) 11. Ex-proof (Ex d T6 IP-66 IIC ) - Flameproof as per IS/IEC 60079-1:2007 - Weatherproof (IP-66) as per IS/IEC 60529:2001 - Suitable for Gas Group : IIC - Suitable for Zone 1 & 2 atmospheres 12. Compact size 13. Low power consumption (0.5 to 0.7 VA) 14. Settable switching delay as a standard feature Integral / Remote Electronics Universal Power Supply, DPDT Relay Output 15 to 80 VDC and 15 to 260 VAC 50/60Hz Potential Free DPDT Relay Output 5 A each @ 24VDC or 220VAC Integral / Remote Electronics for PNP Output 12 to 60 VDC, PNP 250mA max. Short Circuit Safe Integral / Remote Electronics SPDT + PNP Output Universal Supply for SPDT Output 15 to 80 VDC 15 to 260 VAC 50/60Hz DC Supply for PNP Output 15 to 60 VDC Potential Free DPDT Relay Output 5 A each @ 24VDC or 220VAC 250mA max. Short Circuit Safe Integral Electronics AC series relay Two Wire 18 to 260 VAC, Series Relay not less than 4mA to release external relay maximum 150mA to magnetize relay Use relays/contactors will more than 4mA holding current Integral Electronics 4-20mA Loop Powered Two Wire DC 8 / 16 mA 15 to 60 VDC 8mA (±1mA max) / 16mA (±1mA max) Remote electronics require special cable from rod to controller. 10 meter standard length more available on demand >=350 gram/litre, not fluidized -20°C ... 70°C (-4°F ... 158 °F) -20°C ... 80°C (-4°F ... 176 °F) -30°C ... 250°C (-22°F ... 482 °F) (extensions & heat sinks required) absolute / max. 15 bar SS 316 or SS 316L NPT / BSP 1", 1¼", 1½", 2" etc Flanged : ANSI/JIS/DIN/ASA/custom SS 304, SS 316, SS 316L 250mm to 3,000mm 0.5 VA max. EIUD / ERUD Supply & Output Relay Type and Rating EIDP / ERDP Supply & Output Output Limit EIUSP / ERUSP Supply & Output Relay Type and Rating EIAR Supply & Output Output Limit EIDL Supply & Output Output Limit Sensor Cable Min. Density Ambient Temp. Process Temp. Extended Process Temperature Process Pressure Wetted Parts Mountings Extensions Tube Material & Length Power Consumption lsvr-manual-page02 2 www.trumen.in wall/pipe mounting remote electronics special interconnection cable
  • 5. Features Installation Precaution Do's and Don'ts 1. Always connect the "Earth" to the external "Earthing" screw 2. Tighten the cable entries & glands properly 3. Secure the top aluminium cover at its place properly once the electrical connections and other settings are completed 4. Always tighten the process connection using proper wrench never try to tight by rotating the aluminium housing 5. Make sure process connection is same as that in hopper/tank 6. Vibrating rod probe:- 6.1 Should never be bent 6.2 Should never be held from thin part 6.3 Should never be cut or machined in any way 6.4 Should never be extended by welding or machining 7. Cable entries must face downwards only 8. Nozzles should never be longer than the rod sense 9. If mounted directly under the material entry, always install a cannopy of suitable strength at proper height from the rod 10. Never climb either by gripping or stepping over either the rod sense or its aluminium housing 11. Obeserve other safety precautions as required at the place of application 3 2 4 5 1 6 6.2 lsvr-manual-page03 3 www.trumen.in
  • 6. Troubleshooting Maintenance and Spares Top Cover Electronic Insert connection terminals electronic insert fixing screw 4-way male connector for sensor (rod) 4-way female connector from sensor (rod) Cable glands Thermal spacer (where needed) Process connection Extension Sense Device enclosure Shown on the left are various parts of LSVR level switch. Separatable parts are 1. Electronic insert in short called 'electronics' 2. Rod + Enclosure + Cover + Glands collectively called 'mechanical' For maintenance issues involving replacement of 'electronics', just a single fixing screw is needed to be released. Lift the electronics slowly by holding electronics with one hand and mechanical with other, as wires are connected using rigid 4-way connectors to it. Disconnect 4-way connector by holding electronics with one hand and female of connector by other hand, while the rest of the device is at rest. Connect the new replaced sensor. 4-way connector is unidirectional and only connects in proper direction. Set the electronics properly to its position. Match the mounting screw hole of electronics with that of enclosure and fix the screw. For mechanical issues please send the entire device back to Trumen. Applications Indication Probable cause Work-around Solution No switching output or sensor is permanently in alarm If proper voltage is available but 'power' LED is still OFF Power is not available Sensor electronic insert internal power section is failed Sensor electronic insert rod oscillator circuit failed Sensor electronic insert evaluation section failure See if 'power' LED is ON If power LED is OFF check voltage on terminal 1 and 2 Sensor electronic insert is needed to be replaced. Abrupt switching Material is agitated Set time delay to 5 second in both dry and wet condition (turn switch 2, 3 ON) Time delay solves switching issues in agitated materials. Device shows no material after some time even when rod is inside the material Material fluffy or rod rate-holes the material due to its own vibrations Set device in sensitive mode (turn switch 1 ON) Sensitive setting reduces vibrational strength and makes switching point at lower amplitude. Rod settings are all OK but rod fails to switch to 'no material' at random times Power supply carrying extra noise and rod amplifier picking the noise Make necessary arrangements to filter the noise in power-line before being fed to the device Provide an exclusive earthing to terminal# 3, rod enclosure earthing screw and rod process connection (device mounting screw) Device contains sufficient filtering of power supply noise inside, but sometimes external earth is needed to make filters sink the extra power supply noise back to earth. Device worked for few months / years but now fails to switch with respect to material while power conditions are all same Device senses rod frequency and amplitude to ascertain presence / absence of Material. Possible reasons are 1. Rod frequency shift due to rod wear / errosion by service material 2. Material deposition on rod leads 3. Over temperature of service material causing rod drive damage Select proper rod surface while ordering as per service material to mitigate rod errosion as well as deposition Order device of proper thermal grade for proper service life of device Clean up deposited materials on rod sense as a part of maintenance schedule Care is needed to be taken while ordering. Scheduled cleaning of rod sense in sticky material application is recommended. In case of temperature stress, rod sensor is needed to be replaced. Rod is not vibrating when rod sense are touched by hand Rod is vibrating but no switching output when for rod sense are touched by hand Sensor electronic insert is needed to be replaced. lsvr-manual-page04 4 www.trumen.in
  • 7. 1 sensitivity control sensitive setting for low density materials (turn-on for fluffy/low density powders etc) (keep turned-off for normal density materials) 2 “dry” (or uncovered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod out of solid confirmation) 3 “wet” (or covered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod dipped in the material confirmation) 4 minimum failsafe select Failsafe means alarm is same as power failure. Turn on for underflow detection (min. failsafe) Keep turned off for overflow detection (max. failsafe) configuration switches OFF Position ON Position Example of Switch in On and Off Positions 1 + of DC or Live of AC Supply input 2 - of DC or Neutral of AC Supply input Supply: 15 to 80VDC or 15 to 260VAC 50/60Hz 3 Earth terminal for safety 4 Normally connected terminal of contact 1 5 Common terminal of contact 1 6 Normally open terminal of contact 1 7 Normally connected terminal of contact 2 8 Common terminal of contact 2 9 Normally open terminal of contact 2 A Alarm Indicating LED B Configuration Switches C Power ON LED Indicator D Connecting Terminals E External Earthing Terminal controls & indicators connection terminals sensitive dry delay wet delay min failsafe to set turn-on LSVR-UD 5 sec ON Position OFF Position sensitive dry delay wet delay min failsafe to set turn-on LSVR-UD 5 sec status power L1 N U 15... 80V DC 15... 260V AC 1 2 3 4 5 6 7 8 9 D B C A ON E lsvr-manual-annexure-1 www.trumen.in Annexure-1 Introduction - LSVR-UD (EIUD / ERUD) Page 1
  • 8. Vibrating rod is a single element tuned mechanical element type level sensing device. Failsafe defines that the alarm and power failure / device failure conditions are same to the external system. Failsafe operation is best understood with the type of installation and following matrix. Off Off On On Failsafe Setting Material & Installation Status LED Power ON 1 2 3 4 ON min failsafe 1 2 3 4 ON min failsafe 4 5 6 7 8 9 Material Status No material at high level. DPDT Relay Contacts Power OFF Switch no. 4 is off, failsafe high/maximum. Indicating normal or healthy status. 4 5 6 7 8 9 Relay ON normal or healthy contacts. Relay OFF alarm contacts. (due to power failure) No material at low level. Switch no. 4 is on, failsafe low/minimum. Indicating alarm status. 4 5 6 7 8 9 Relay OFF alarm contacts. 4 5 6 7 8 9 1 2 3 4 ON min failsafe Indicating alarm status. 4 5 6 7 8 9 Relay OFF alarm contacts. 4 5 6 7 8 9 Relay OFF alarm contacts. (as it is) Material is above the low level or rod is covered with material 1 2 3 4 ON min failsafe Switch no. 4 is on, failsafe low/minimum. 4 5 6 7 8 9 4 5 6 7 8 9 Material is above the high level or rod is covered with material. Indicating normal or healthy status. Relay ON normal or healthy contacts. High level / overflow detection Low level / underflow detection lsvr-manual-annexure-1 www.trumen.in Annexure-1 Operation Matrix - LSVR-UD (EIUD / ERUD) Page 2 Switch no. 4 is off, failsafe high/maximum. Relay OFF alarm contacts. (as it is) Relay OFF alarm contacts. (due to power failure)
  • 9. Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must. electrical connections (AC) lsvr-manual-annexure-1 www.trumen.in electrical connections (DC) DC 15 to 80 VDC output contact 1 output contact 2 sensitive dry delay wet delay min failsafe to set turn-on LSVR-UD status power L1 N U 15... 80V DC 15... 260V AC 1 2 3 4 5 6 7 8 9 ON output contact 1 output contact 2 Live Neutral 15 to 260 VAC 50/60 Hz sensitive dry delay wet delay min failsafe to set turn-on LSVR-UD status power L1 N U 15... 80V DC 15... 260V AC 1 2 3 4 5 6 7 8 9 ON Electrical Connections - LSVR-UD (EIUD / ERUD) Annexure-1 1 2 3 Red White Black Page 3 sensitive dry delay wet delay min failsafe to set turn-on LSVR-UD 5 sec status power L1 N U 15... 80 VDC 15... 260 VAC 1 2 3 4 5 6 7 8 9 ON Remote probe connections for LSVR-UD (ERUD)
  • 10. 1 sensitivity control sensitive setting for low density materials (turn-on for fluffy/low density powders etc) (keep turned-off for normal density materials) 2 “dry” (or uncovered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod out of material confirmation) 3 “wet” (or covered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod dipped in the material confirmation) 4 minimum failsafe select Failsafe means alarm is same as power failure. Turn on for underflow detection (min. failsafe) Keep turned off for overflow detection (max. failsafe) configuration switches OFF Position ON Position Example of Switch in On and Off Positions 1 + of DC Supply input 2 - of DC Supply input Supply: 12 to 60VDC 3 Earth terminal for safety 4 PNP output is supplied with voltage 12 to 60VDC A Alarm Indicating LED B Configuration Switches C Power ON LED Indicator D Connecting Terminals E External Earthing Terminal controls & indicators connection terminals sensitive dry delay wet delay min failsafe to set turn-on LSVR-DP 5 sec ON Position OFF Position sensitive dry delay wet delay min failsafe to set turn-on LSVR-DP 5 sec status power U 12 to 60V DC 1 2 3 4 5 6 7 8 9 D B C A PNP (alarm=float) ON E lsvr-manual-annexure-2 www.trumen.in Annexure-2 Introduction - LSVR-DP (EIDP / ERDP) Page 1
  • 11. Vibrating rod is a single element tuned mechanical element type level sensing device. Failsafe defines that the alarm and power failure / device failure conditions are same to the external system. Failsafe operation is best understood with the type of installation and following matrix. Off Off On On Failsafe Setting Material & Installation Status LED Power ON 1 2 3 4 ON min failsafe 1 2 3 4 ON min failsafe Material Status No material at high level. PNP Output Power OFF Switch no. 4 is off, failsafe high/maximum. Indicating normal or healthy status. Normal or healthy output. Alarm output. (due to power failure) No material at low level. Switch no. 4 is on, failsafe low/minimum. Indicating alarm status. 1 2 3 4 ON min failsafe Indicating alarm status. Material is above the low level or rod is covered with material. 1 2 3 4 ON min failsafe Material is above the high level or rod is covered with material. Indicating normal or healthy status. High level / overflow detection Low level / underflow detection 1 2 3 4 IL IL(max) = 250mA Ileak ≤ 0.1mA 1 2 3 4 Ileak Ileak ≤ 0.1mA 1 2 3 4 Ileak Ileak ≤ 0.1mA 1 2 3 4 Ileak Ileak ≤ 0.1mA 1 2 3 4 Ileak Ileak ≤ 0.1mA 1 2 3 4 Ileak 1 2 3 4 IL IL(max) = 250mA Ileak ≤ 0.1mA 1 2 3 4 Ileak Alarm output. (as it is) Alarm output. Alarm output. (as it is) Alarm output. Normal or healthy output. lsvr-manual-annexure-2 www.trumen.in Annexure-2 Operation Matrix - LSVR-DP (EIDP / ERDP) Page 2 Alarm output. (due to power failure) Switch no. 4 is off, failsafe high/maximum. Switch no. 4 is on, failsafe low/minimum.
  • 12. Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must. lsvr-manual-annexure-2 www.trumen.in electrical connections (DC) sensitive dry delay wet delay min failsafe to set turn-on LSVR-DP 5 sec status power U 12 to 60V DC 1 2 3 4 5 6 7 8 9 PNP (alarm=float) output unused terminals DC 12 to 60 VDC ON Electrical Connections - LSVR-DP (EIDP / ERDP) Annexure-2 1 2 3 Red White Black sensitive dry delay wet delay min failsafe to set turn-on LSVR-DP 5 sec status power U 12 to 60V DC 1 2 3 4 5 6 7 8 9 PNP (alarm=float) ON Page 3 Remote probe connections for LSVR-DP (ERDP)
  • 13. Introduction - LSVR-U(S+P) (EIUSP / ERUSP) 1 sensitivity control sensitive setting for low density materials (turn-on for fluffy/low density materials) (keep turned-off for normal materials) 2 “dry” (or uncovered) delay (5 second delay) (turn-on when 5 second more time is needed for rod out of material confirmation) 3 “wet” (or covered) delay (5 second delay) (turn-on when 5 second more time is needed for rod dipped in the material confirmation) 4 minimum failsafe select Failsafe means alarm is same as power failure. Turn on for underflow detection (min. failsafe) Keep turned off for overflow detection (max. failsafe) configuration switches OFF Position ON Position Example of Switch in On and Off Positions 1 (+) of DC or Live of AC Supply input 2 (-) of DC or Neutral of AC Supply input Supply: 15 to 80VDC or 15 to 260VAC 50/60Hz 3 Earth terminal for safety 4 Normally connected terminal of SPDT contact 5 Common terminal of SPDT contact 6 Normally open terminal of SPDT contact 7 (-) of DC for PNP output 8 (+) of DC for PNP output 9 DC PNP output with respect to -ve of DC Supply should be within 15 to 60VDC for PNP output A Alarm Indicating LED B Configuration Switches C Power ON LED Indicator D Connecting Terminals E External Earthing Terminal controls & indicators connection terminals sensitive dry delay wet delay min failsafe to set turn-on LSVR-U(S+P) 5 Sec ON Position OFF Position lsvr-manual-annexure-3 www.trumen.in Page 1 Annexure-3 ! sensitive dry delay wet delay min failsafe to set turn-on LSVR-U(S+P) 5 Sec status power L1 N U 15... 80V DC 15... 260V AC 1 2 3 4 5 6 7 8 9 D B C A E ON U 15... 60V DC PNP o/p ! less than 60VDC only
  • 14. Failsafe defines that the alarm and power failure / device failure conditions are same to the external system. Failsafe operation is best understood with the type of installation and following matrix. Operation Matrix - LSVR-U(S+P) (EIUSP / ERUSP) lsvr-manual-annexure-3 www.trumen.in Annexure-3 Page 2 Off Off On On Failsafe Setting Material & Installation Status LED 1 2 3 4 ON min failsafe 1 2 3 4 ON min failsafe Material Status No material at high level. Switch no. 4 is off, failsafe high/maximum Relay Contacts & PNP Output Indicating normal or healthy status. Power ON Power OFF 1 2 3 4 ON min failsafe Switch no. 4 is off, failsafe high/maximum Material is above the high level or rod is covered with material. Indicating alarm status. No material at low level. Switch no. 4 is on, failsafe low/minimum Indicating alarm status. Material is above the low level or rod is covered with material. 1 2 3 4 ON min failsafe Switch no. 4 is on, failsafe low/minimum Indicating normal or healthy status. High level / overflow detection Low level / underflow detection 4 5 6 4 5 6 Relay ON normal or healthy contacts. Relay OFF alarm contacts. (due to power failure) Relay OFF alarm contacts. Relay OFF alarm contacts. (as it is) Ileak ≤ 0.1mA 7 8 9 Ileak 7 8 9 IL IL(max) = 250mA 7 8 9 Ileak Ileak ≤ 0.1mA 7 8 9 Ileak Ileak ≤ 0.1mA 7 8 9 Ileak Ileak ≤ 0.1mA 7 8 9 Ileak Ileak ≤ 0.1mA 4 5 6 4 5 6 Relay OFF alarm contacts. Relay OFF alarm contacts. (as it is) 4 5 6 4 5 6 4 5 6 4 5 6 Relay ON normal or healthy contacts. Relay OFF alarm contacts. (due to power failure) Ileak ≤ 0.1mA 7 8 9 Ileak 7 8 9 IL IL(max) = 250mA
  • 15. Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must. lsvr-manual-annexure-3 www.trumen.in Electrical Connections - LSVR-U(S+P) (EIUSP / ERUSP) Annexure-3 1 2 3 Red White Black Page 3 output contact Live Neutral 15 to 260 VAC 50/60 Hz sensitive dry delay wet delay min failsafe to set turn-on LSVR-U(S+P) 5 Sec status power L1 N U 15... 80V DC 15... 260V AC 1 2 3 4 5 6 7 8 9 ON U 15... 60V DC PNP o/p ! less than 60VDC only PNP output DC 15 to 60 VDC output contact sensitive dry delay wet delay min failsafe to set turn-on LSVR-U(S+P) 5 Sec status power L1 N U 15... 80V DC 15... 260V AC 1 2 3 4 5 6 7 8 9 ON U 15... 60V DC PNP o/p ! less than 60VDC only PNP output electrical connections (AC) electrical connections (DC) sensitive dry delay wet delay min failsafe to set turn-on LSVR-U(S+P) 5 Sec status power L1 N U 15... 80V DC 15... 260V AC 1 2 3 4 5 6 7 8 9 ON U 15... 60V DC PNP o/p ! less than 60VDC only Remote probe connections for LSVR-U(S+P) (ERUSP)
  • 16. 1 Not used 2 “dry” (or uncovered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod out of material confirmation) 3 “wet” (or covered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod dipped in the material confirmation) 4 minimum failsafe select Failsafe means alarm is same as power failure. Turn on for underflow detection (min. failsafe) Keep turned off for overflow detection (max. failsafe) configuration switches OFF Position ON Position Example of Switch in On and Off Positions 1 Live of AC Supply through fuse 2 Neutral of AC Supply input through specified series relay 18 to 260VAC 50/60 Hz series 3 Earth terminal for safety 4,5,6,7,8,9 Not used A Alarm Indicating LED B Configuration Switches C Normal LED Indicator D Connecting Terminals E External Earthing Terminal controls & indicators connection terminals x dry delay wet delay min failsafe to set turn-on LSVR-AR 5 sec ON Position OFF Position lsvr-manual-annexure-4 www.trumen.in Annexure-4 Introduction - LSVR-AR (EIAR) Page 1 x dry delay wet delay to set turn-on LSVR-AR 5 sec alarm normal U 18... 260V AC 1 2 3 4 5 6 7 8 9 D B C A E ON min failsafe 2 wire AC series Relay (<5mA holding current)
  • 17. Series relay will be energized in normal or healthy condition. Series relay will be de- energized in alarm condition. Failsafe defines that the alarm and power failure / device failure conditions are same to the external system. Failsafe operation is best understood with the type of installation and following matrix. Normal or healthy Off Alarm Alarm On Failsafe Setting Material & Installation Status LED 1 2 3 4 ON min failsafe 1 2 3 4 ON min failsafe Switching Operation When switch no. 4 is off (failsafe high / maximum). output status shows normal when there is no material at high switch point or rod is out of the material. When switch no. 4 is off (failsafe high / maximum). output status shows alarm if rod is dipped in material at high switch point. When switch no. 4 is on (failsafe low / minimum). output status shows alarm when there is no material at low switch point or rod is out of the material. When switch no. 4 is on (failsafe low / minimum). output status shows normal if rod is dipped in material at low switch point. Series Relay Status Alarm/ Normal lsvr-manual-annexure-4 www.trumen.in Page 2 Annexure-4 Operation Matrix - LSVR-AR (EIAR) High level / overflow detection Low level / underflow detection Power ON Power OFF 1 2 3 4 ON min failsafe Series relay on Series relay off (due to power failure) Red Green On Red Off Green 1 2 3 4 ON min failsafe Normal or healthy Off On Red Green On Red Off Green Series relay off Series relay off (as it is) Series relay off Series relay off (as it is) Series relay on Series relay off (due to power failure) 1 2 L N 1 2 L N 1 2 L N 1 2 L N 1 2 L N 1 2 L N 1 2 L N 1 2 L N
  • 18. Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must. lsvr-manual-annexure-4 www.trumen.in Annexure-4 Electrical Connections - LSVR-AR (EIAR) electrical connections (AC) Page 3 x dry delay wet delay to set turn-on LSVR-AR 5 sec alarm normal U 18... 260V AC 1 2 3 4 5 6 7 8 9 ON min failsafe 2 wire AC series Relay (<5mA holding current) x dry delay wet delay to set turn-on LSVR-AR 5 sec alarm normal U 18... 260V AC 1 2 3 4 5 6 7 8 9 ON min failsafe 2 wire AC series Relay (<5mA holding current) Not Used L N AC Supply 18 to 260 VAC Specified AC Series Relay Use AC relay / contactor having maximum 150mA to magnetize and holding current should not be less than 4mA. Voltage rating of AC relay should be as per input supply voltage.
  • 19. 1 sensitivity control sensitive setting for low density materials (turn-on for fluffy / low density materials etc.) (keep turned-off for normal density materials) 2 “dry” (or uncovered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod out of material confirmation) 3 “wet” (or covered) delay (5 second delay) setting (turn-on when 5 second more time is needed for rod dipped in the material confirmation) 4 minimum failsafe select Failsafe means alarm is same as power failure. Turn on for underflow detection (min. failsafe) Keep turned off for overflow detection (max. failsafe) configuration switches OFF Position ON Position Example of Switch in On and Off Positions 1 (+) of DC Supply input 2 (-) of DC Supply input DC Supply: 12 to 60VDC 3 Earth terminal for safety 4,5,6,7,8,9 Not used A Alarm Indicating LED B Configuration Switches C Power ON LED Indicator D Connecting Terminals E External Earthing Terminal controls & indicators connection terminals sensitive dry delay wet delay min failsafe to set turn-on LSVR-DL-8/16 5 sec ON Position OFF Position lsvr-manual-annexure-5 www.trumen.in Annexure-5 Introduction - LSVR-DL (EIDL) 8/16 mA Output Page 1 sensitive dry delay wet delay min failsafe to set turn-on LSVR-DL-8/16 5 sec alarm power U 12 to 60V DC 1 2 3 4 5 6 7 8 9 D B C A E ON Loop powered 8mA ± 1mA (alarm) 16mA ± 1mA (normal)
  • 20. Miliampere output 16 is supplied in normal or healthy condition. Miliampere output 8 is supplied in alarm condition. Failsafe defines that the alarm and power failure / device failure conditions are same to the external system. Failsafe operation is best understood with the type of installation and following matrix. Normal Off Off Alarm On On Failsafe Setting Material & Installation Status LED 1 2 3 4 ON min failsafe 1 2 3 4 ON min failsafe Switching Operation When switch no. 4 is off (failsafe high / maximum). output status shows normal when there is no material at high switch point or rod is out of the material. When switch no. 4 is off (failsafe high / maximum). output status shows alarm if rod is dipped in material at high switch point. When switch no. 4 is on (failsafe low / minimum). output status shows alarm when there is no material at low switch point or rod is out of the material. When switch no. 4 is on (failsafe low / minimum). output status shows normal if rod is dipped in material at low switch point. Miliampere Output Status lsvr-manual-annexure-5 www.trumen.in Page 2 Annexure-5 Operation Matrix - LSVR-DL (EIDL) High level / overflow detection Low level / underflow detection 1 2 3 4 ON min failsafe 1 2 3 4 ON min failsafe 1 2 DC IL IL IL = 16mA 1 2 DC IL IL IL = 8mA 1 2 DC IL IL IL = 8mA 1 2 DC IL IL IL = 16mA Normal Alarm
  • 21. Electrical Connections - LSVR-DL (EIDL) Proper connection to supply earth terminal (3) and the external earth terminal (screw) is must. electrical connections (DC) lsvr-manual-annexure-5 www.trumen.in Page 3 Annexure-5 Not used 1 2 3 4 5 6 7 8 9 sensitive dry delay wet delay min failsafe to set turn-on LSVR-DL-8/16 5 sec alarm power U 12 to 60V DC ON Loop powered 8mA ± 1mA (alarm) 16mA ± 1mA (normal) sensitive dry delay wet delay min failsafe to set turn-on LSVR-DL-8/16 5 sec alarm power U 12 to 60V DC 1 2 3 4 5 6 7 8 9 ON Loop powered 8mA ± 1mA (alarm) 16mA ± 1mA (normal) Supply 12 to 60 VDC mA Meter/Indicator/PLC/SCADA