8. A
A
C
C
D
D
2,850
150
3,000
1,050
1,600
1,250
1,750
350
Concrete gutter with wall
master finish to approval
150mm thick concrete slab on 500gauge approved
damp proof membrane 50mm aprroved murram blinding
treated with anti-termite on 300mm well compacted
hardcore.
ROOF PITCH
IT5/BP950 profiled sheets on
timber rafters and trusses to
se's details.
Heavy duty bronze & natural
anodized alluminium windows
frames(glass & ironmongery m/s)
Reinforced concrete sunshading beam with
wall master finish to approval .
SECTION-01 X-X