PLAN VIEW
1180
Splitter block at outlet
750
150
900
150
900
SECTION
150
150
600
Stone Pitched
150
2250
OUTLET STRUCTURE
650
Road Finished Level
200Min.520300150
275 275
NotLessThan820
1000
TYPICAL TRENCH SECTION
Road Finished Level
Min.420300
Min.920
Compacted Fill (Should Not Contain
Stones Greater Than 50mm)
Compacted Selected Backfill Sieved
Material (Should Not Contain Stones
Greater Than 10mm)
TYPICAL TRENCH SECTION UNDER VEHICLE AREA
RoadLayer
Works
Compacted Fill (Should Not Contain
Stones Greater Than 50mm)
Compacted Selected Backfill Sieved
Material (Should Not Contain Stones
Greater Than 10mm)
4-6 Granular Bedding Material
450
150
275 275
4-6 Granular Bedding Material
450
Joint sealed with min. 200thk
mass concrete all round
UPVC Pipe
from Road Gully
Hole cut through wall of concrete storm water pipe
- to be as neat and small as possible
JOINT BETWEEN STORM DRAIN & GULLY OUTLET
SECTION X - X
XX
constraint requires larger angle
Flexible sealing membrane like
ABE ecofelt membrane impregnated
with superlacryl emulsion
Flexible sealing membrane like
ABE ecofelt membrane impregnated
with superlacryl emulsion
750
150mm Thick Concrete
G25 Base And Surround
TYPICAL ROAD GULLY DETAIL (ON ROAD 4)
375
Proprietory Road Gully Pot
To be approved by Engineer
Insitu concrete ring beam min
100mm thk, set to correct
level to receive grating base
Mortar Fillet
D400 Heavy Duty Grating 430 x 370
Base 525 x 525
Bedded On Mortar
600mm Long 150mm Removable
Stopper
Top of Grating to be set within the range
+0 to -5mm relative to finished road level
150 150700
1000
DISH DRAIN DETAILS
200
50mm Blinding Layer
Grade 30MPA Concrete
Road Finished Levels
12175
25x25mm Chamfer
Y8 at 150 c/c - B1
Y8 at 150 c/c - B2
50
75
Job No
Drawing Status
Discipline
Scale at A1
Drawing No Rev
Drawing Title
Job Title
Client
Date By Chkd Appd
A1
1
2
3
4
5
6
7
8
9
10
11
A B C D E F G H I J K L M N
Do not scale
Rev
CD-302 C22878
1:10
FOR CONSTRUCTION
Civil
TYPICAL STORMWATER DETAILS
/ /C1 20 02 13 Reza B. P.G P.G
ISSUED FOR CONSTRUCTION
/ /C2 25 02 13 Reza B. P.G P.G
REINF. TO DISH DRAIN ADDED

Mais conteúdo relacionado

Mais procurados

accelerated bridge construction(ABC)
accelerated bridge construction(ABC)accelerated bridge construction(ABC)
accelerated bridge construction(ABC)varun km
 
Precast concrete structures
Precast concrete structuresPrecast concrete structures
Precast concrete structuresAglaia Connect
 
Sub Structure Construction.pptx
Sub Structure Construction.pptxSub Structure Construction.pptx
Sub Structure Construction.pptxAnanthakumar75
 
Underwater construction
Underwater constructionUnderwater construction
Underwater constructionHetviPatel58
 
Jensen Precast Redi-Rock Retaining Walls
Jensen Precast Redi-Rock Retaining WallsJensen Precast Redi-Rock Retaining Walls
Jensen Precast Redi-Rock Retaining WallsJensen Precast
 
Load analysis and structural consideration
Load analysis and structural considerationLoad analysis and structural consideration
Load analysis and structural considerationBee Key Verma
 
Detailed design of portal frames
Detailed design of portal framesDetailed design of portal frames
Detailed design of portal frameskaran prabhakar
 
Foundation Rehabilitation
Foundation RehabilitationFoundation Rehabilitation
Foundation RehabilitationAani4
 
Outrigger belt trusses design - الجائز الشبكي المركزي والحزام المحيطي مع جد...
Outrigger belt  trusses design - الجائز الشبكي المركزي  والحزام المحيطي مع جد...Outrigger belt  trusses design - الجائز الشبكي المركزي  والحزام المحيطي مع جد...
Outrigger belt trusses design - الجائز الشبكي المركزي والحزام المحيطي مع جد...Dr.Youssef Hammida
 
Constructions Et Batiments
Constructions Et BatimentsConstructions Et Batiments
Constructions Et BatimentsOURAHOU Mohamed
 

Mais procurados (20)

accelerated bridge construction(ABC)
accelerated bridge construction(ABC)accelerated bridge construction(ABC)
accelerated bridge construction(ABC)
 
Sr. Larbi Sennour
Sr. Larbi SennourSr. Larbi Sennour
Sr. Larbi Sennour
 
Precast concrete structures
Precast concrete structuresPrecast concrete structures
Precast concrete structures
 
Monolithic dome ppt
Monolithic dome pptMonolithic dome ppt
Monolithic dome ppt
 
Sub Structure Construction.pptx
Sub Structure Construction.pptxSub Structure Construction.pptx
Sub Structure Construction.pptx
 
Roofing members
Roofing membersRoofing members
Roofing members
 
Underwater construction
Underwater constructionUnderwater construction
Underwater construction
 
Jensen Precast Redi-Rock Retaining Walls
Jensen Precast Redi-Rock Retaining WallsJensen Precast Redi-Rock Retaining Walls
Jensen Precast Redi-Rock Retaining Walls
 
Load analysis and structural consideration
Load analysis and structural considerationLoad analysis and structural consideration
Load analysis and structural consideration
 
Ferrocement
FerrocementFerrocement
Ferrocement
 
Special structure
Special structureSpecial structure
Special structure
 
Quality Control for Masonry
Quality Control for MasonryQuality Control for Masonry
Quality Control for Masonry
 
Detailed design of portal frames
Detailed design of portal framesDetailed design of portal frames
Detailed design of portal frames
 
EC3 MANUAL FOR SAP2000
EC3 MANUAL FOR SAP2000EC3 MANUAL FOR SAP2000
EC3 MANUAL FOR SAP2000
 
Foundation Rehabilitation
Foundation RehabilitationFoundation Rehabilitation
Foundation Rehabilitation
 
Outrigger belt trusses design - الجائز الشبكي المركزي والحزام المحيطي مع جد...
Outrigger belt  trusses design - الجائز الشبكي المركزي  والحزام المحيطي مع جد...Outrigger belt  trusses design - الجائز الشبكي المركزي  والحزام المحيطي مع جد...
Outrigger belt trusses design - الجائز الشبكي المركزي والحزام المحيطي مع جد...
 
Etabs multistory-steel
Etabs multistory-steelEtabs multistory-steel
Etabs multistory-steel
 
Concrete cloth
Concrete clothConcrete cloth
Concrete cloth
 
Constructions Et Batiments
Constructions Et BatimentsConstructions Et Batiments
Constructions Et Batiments
 
Prestressed construction
Prestressed constructionPrestressed construction
Prestressed construction
 

Semelhante a 2878-CD-302 TYPICAL STORMWATER DETAILS

Semelhante a 2878-CD-302 TYPICAL STORMWATER DETAILS (20)

FBP_1200 Series details-1213
FBP_1200 Series details-1213FBP_1200 Series details-1213
FBP_1200 Series details-1213
 
OCHAI 002
OCHAI 002OCHAI 002
OCHAI 002
 
House Carol Submission
House Carol SubmissionHouse Carol Submission
House Carol Submission
 
Ktrimbee A-4
Ktrimbee A-4Ktrimbee A-4
Ktrimbee A-4
 
Ktrimbee A-4
Ktrimbee A-4Ktrimbee A-4
Ktrimbee A-4
 
2878-CR-201 TYPICAL ROAD SECTION
2878-CR-201 TYPICAL ROAD SECTION2878-CR-201 TYPICAL ROAD SECTION
2878-CR-201 TYPICAL ROAD SECTION
 
Project1
Project1Project1
Project1
 
House Odendahl (SECTIONS&ELEVATIONS)-A1 (2)
House Odendahl (SECTIONS&ELEVATIONS)-A1 (2)House Odendahl (SECTIONS&ELEVATIONS)-A1 (2)
House Odendahl (SECTIONS&ELEVATIONS)-A1 (2)
 
House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1
 
Bo q for shelter
Bo q  for shelterBo q  for shelter
Bo q for shelter
 
section and detail sheet1
section and detail sheet1section and detail sheet1
section and detail sheet1
 
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILSMill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
 
Plastech Titan
Plastech TitanPlastech Titan
Plastech Titan
 
Jack_Lambourne - Portfolio
Jack_Lambourne - PortfolioJack_Lambourne - Portfolio
Jack_Lambourne - Portfolio
 
Diaphragm wall
Diaphragm wallDiaphragm wall
Diaphragm wall
 
Structural glazing details
Structural glazing detailsStructural glazing details
Structural glazing details
 
Knife Edge Gate Valve
Knife Edge Gate ValveKnife Edge Gate Valve
Knife Edge Gate Valve
 
Masonry-Special-Features (1).pdf
Masonry-Special-Features (1).pdfMasonry-Special-Features (1).pdf
Masonry-Special-Features (1).pdf
 
Masonry-Special-Features.pdf
Masonry-Special-Features.pdfMasonry-Special-Features.pdf
Masonry-Special-Features.pdf
 
011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan
 

Mais de Reza Bassawon

2878-CR-002 ROAD MARKING
2878-CR-002 ROAD MARKING2878-CR-002 ROAD MARKING
2878-CR-002 ROAD MARKINGReza Bassawon
 
2878-CD-001 STORMWATER NETWORK
2878-CD-001 STORMWATER NETWORK2878-CD-001 STORMWATER NETWORK
2878-CD-001 STORMWATER NETWORKReza Bassawon
 
2878-CR-402 FINISHED ROAD LEVELS
2878-CR-402 FINISHED ROAD LEVELS2878-CR-402 FINISHED ROAD LEVELS
2878-CR-402 FINISHED ROAD LEVELSReza Bassawon
 
2878-CR-305 ROAD STATIONAL CROSS SECTION
2878-CR-305 ROAD STATIONAL CROSS SECTION2878-CR-305 ROAD STATIONAL CROSS SECTION
2878-CR-305 ROAD STATIONAL CROSS SECTIONReza Bassawon
 
2878-CR-102 LONG SECTION along ROAD
2878-CR-102 LONG SECTION along ROAD2878-CR-102 LONG SECTION along ROAD
2878-CR-102 LONG SECTION along ROADReza Bassawon
 
2878-CC-002 COORDINATED SERVICES LAYOUT
2878-CC-002 COORDINATED SERVICES LAYOUT2878-CC-002 COORDINATED SERVICES LAYOUT
2878-CC-002 COORDINATED SERVICES LAYOUTReza Bassawon
 
2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELS
2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELS2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELS
2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELSReza Bassawon
 
2878-CC-001 COORDINATED SERVICES LAYOUT
2878-CC-001 COORDINATED SERVICES LAYOUT2878-CC-001 COORDINATED SERVICES LAYOUT
2878-CC-001 COORDINATED SERVICES LAYOUTReza Bassawon
 
2759-SW-101 LS Along Sewer Line
2759-SW-101 LS Along Sewer Line2759-SW-101 LS Along Sewer Line
2759-SW-101 LS Along Sewer LineReza Bassawon
 

Mais de Reza Bassawon (11)

Bagatelle Earthwork
Bagatelle EarthworkBagatelle Earthwork
Bagatelle Earthwork
 
Choisy Platform
Choisy PlatformChoisy Platform
Choisy Platform
 
2878-CR-002 ROAD MARKING
2878-CR-002 ROAD MARKING2878-CR-002 ROAD MARKING
2878-CR-002 ROAD MARKING
 
2878-CD-001 STORMWATER NETWORK
2878-CD-001 STORMWATER NETWORK2878-CD-001 STORMWATER NETWORK
2878-CD-001 STORMWATER NETWORK
 
2878-CR-402 FINISHED ROAD LEVELS
2878-CR-402 FINISHED ROAD LEVELS2878-CR-402 FINISHED ROAD LEVELS
2878-CR-402 FINISHED ROAD LEVELS
 
2878-CR-305 ROAD STATIONAL CROSS SECTION
2878-CR-305 ROAD STATIONAL CROSS SECTION2878-CR-305 ROAD STATIONAL CROSS SECTION
2878-CR-305 ROAD STATIONAL CROSS SECTION
 
2878-CR-102 LONG SECTION along ROAD
2878-CR-102 LONG SECTION along ROAD2878-CR-102 LONG SECTION along ROAD
2878-CR-102 LONG SECTION along ROAD
 
2878-CC-002 COORDINATED SERVICES LAYOUT
2878-CC-002 COORDINATED SERVICES LAYOUT2878-CC-002 COORDINATED SERVICES LAYOUT
2878-CC-002 COORDINATED SERVICES LAYOUT
 
2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELS
2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELS2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELS
2878-CR-404 FUTURE ACCESS FINISHED ROAD LEVELS
 
2878-CC-001 COORDINATED SERVICES LAYOUT
2878-CC-001 COORDINATED SERVICES LAYOUT2878-CC-001 COORDINATED SERVICES LAYOUT
2878-CC-001 COORDINATED SERVICES LAYOUT
 
2759-SW-101 LS Along Sewer Line
2759-SW-101 LS Along Sewer Line2759-SW-101 LS Along Sewer Line
2759-SW-101 LS Along Sewer Line
 

2878-CD-302 TYPICAL STORMWATER DETAILS

  • 1. PLAN VIEW 1180 Splitter block at outlet 750 150 900 150 900 SECTION 150 150 600 Stone Pitched 150 2250 OUTLET STRUCTURE 650 Road Finished Level 200Min.520300150 275 275 NotLessThan820 1000 TYPICAL TRENCH SECTION Road Finished Level Min.420300 Min.920 Compacted Fill (Should Not Contain Stones Greater Than 50mm) Compacted Selected Backfill Sieved Material (Should Not Contain Stones Greater Than 10mm) TYPICAL TRENCH SECTION UNDER VEHICLE AREA RoadLayer Works Compacted Fill (Should Not Contain Stones Greater Than 50mm) Compacted Selected Backfill Sieved Material (Should Not Contain Stones Greater Than 10mm) 4-6 Granular Bedding Material 450 150 275 275 4-6 Granular Bedding Material 450 Joint sealed with min. 200thk mass concrete all round UPVC Pipe from Road Gully Hole cut through wall of concrete storm water pipe - to be as neat and small as possible JOINT BETWEEN STORM DRAIN & GULLY OUTLET SECTION X - X XX constraint requires larger angle Flexible sealing membrane like ABE ecofelt membrane impregnated with superlacryl emulsion Flexible sealing membrane like ABE ecofelt membrane impregnated with superlacryl emulsion 750 150mm Thick Concrete G25 Base And Surround TYPICAL ROAD GULLY DETAIL (ON ROAD 4) 375 Proprietory Road Gully Pot To be approved by Engineer Insitu concrete ring beam min 100mm thk, set to correct level to receive grating base Mortar Fillet D400 Heavy Duty Grating 430 x 370 Base 525 x 525 Bedded On Mortar 600mm Long 150mm Removable Stopper Top of Grating to be set within the range +0 to -5mm relative to finished road level 150 150700 1000 DISH DRAIN DETAILS 200 50mm Blinding Layer Grade 30MPA Concrete Road Finished Levels 12175 25x25mm Chamfer Y8 at 150 c/c - B1 Y8 at 150 c/c - B2 50 75 Job No Drawing Status Discipline Scale at A1 Drawing No Rev Drawing Title Job Title Client Date By Chkd Appd A1 1 2 3 4 5 6 7 8 9 10 11 A B C D E F G H I J K L M N Do not scale Rev CD-302 C22878 1:10 FOR CONSTRUCTION Civil TYPICAL STORMWATER DETAILS / /C1 20 02 13 Reza B. P.G P.G ISSUED FOR CONSTRUCTION / /C2 25 02 13 Reza B. P.G P.G REINF. TO DISH DRAIN ADDED