Enviar pesquisa
Carregar
Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing
•
7 gostaram
•
4,332 visualizações
Muhammad Sarfraz
Seguir
Denunciar
Compartilhar
Denunciar
Compartilhar
1 de 26
Baixar agora
Baixar para ler offline
Recomendados
PLC Control Panel for Tobacco Filling Station
PLC Control Panel for Tobacco Filling Station
Muhammad Sarfraz
PLC Control Panel for HVACR System
PLC Control Panel for HVACR System
Muhammad Sarfraz
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Thorne & Derrick International
Sld for pmcc
Sld for pmcc
Avneet Monga
Visio-BMS
Visio-BMS
Muhammad Sarfraz
Electrical substation (one and half breaker scheme)
Electrical substation (one and half breaker scheme)
Sourabh sharma
Invt gd100-user-manual
Invt gd100-user-manual
Toàn Huỳnh
Iec 62271 200 (edition 2011)
Iec 62271 200 (edition 2011)
Michellelelelele Galicia
Recomendados
PLC Control Panel for Tobacco Filling Station
PLC Control Panel for Tobacco Filling Station
Muhammad Sarfraz
PLC Control Panel for HVACR System
PLC Control Panel for HVACR System
Muhammad Sarfraz
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Thorne & Derrick International
Sld for pmcc
Sld for pmcc
Avneet Monga
Visio-BMS
Visio-BMS
Muhammad Sarfraz
Electrical substation (one and half breaker scheme)
Electrical substation (one and half breaker scheme)
Sourabh sharma
Invt gd100-user-manual
Invt gd100-user-manual
Toàn Huỳnh
Iec 62271 200 (edition 2011)
Iec 62271 200 (edition 2011)
Michellelelelele Galicia
Copper Cable Lugs and Terminals Catalogue
Copper Cable Lugs and Terminals Catalogue
Grey Hawk Electricals
Single line diagram ats apfc
Single line diagram ats apfc
Sajeewa Lakmal
ppt on industrial training of final year studen from ptcul 132kv substation ...
ppt on industrial training of final year studen from ptcul 132kv substation ...
surendra rawat
220kv substation
220kv substation
Anbarasu Balakrishnan
Cpc 100 user manual
Cpc 100 user manual
SARAVANAN A
220 66 kv nrs sub report
220 66 kv nrs sub report
Mayur Dhanaji Rane
PLC and Industrial Automation - Technology Overview
PLC and Industrial Automation - Technology Overview
Nereus Fernandes
Gis basics
Gis basics
Satish Kumar
SPS Heat Shrink Cable Terminations 11kV 33kV - Minimum Air Clearances (Cable...
SPS Heat Shrink Cable Terminations 11kV 33kV - Minimum Air Clearances (Cable...
Thorne & Derrick International
MCC PANEL WIRING, GA and BOM Sample
MCC PANEL WIRING, GA and BOM Sample
Shashi Kant
UHF partial discharge detection system for GIS Application guide for sensitiv...
UHF partial discharge detection system for GIS Application guide for sensitiv...
Power System Operation
Plc project report
Plc project report
Umair Rashid
220 KV Switchyard general overview
220 KV Switchyard general overview
Thien Huynh
SWITCHYARD EQUIPMENTS & PROTECTION SYSTEMS
SWITCHYARD EQUIPMENTS & PROTECTION SYSTEMS
Partha Parida
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...
AKBAR TRADING
Schneider RM6 - MV Medium Voltage Compact Switchboard (Ring Main Unit) up to ...
Schneider RM6 - MV Medium Voltage Compact Switchboard (Ring Main Unit) up to ...
Thorne & Derrick International
Photovoltaic IV Curve Analysis
Photovoltaic IV Curve Analysis
Dimas Kaharudin
Pfisterer Cable Fittings 11kV 33kV 52kV - Pfisterer MV-CONNEX Inner Cone Plug...
Pfisterer Cable Fittings 11kV 33kV 52kV - Pfisterer MV-CONNEX Inner Cone Plug...
Thorne & Derrick International
Presentacion arco interno
Presentacion arco interno
jahkurt
Honeywell PLC TRAINING GUIDE created by deepak gorai
Honeywell PLC TRAINING GUIDE created by deepak gorai
DEEPAK GORAI
PLC based load managment
PLC based load managment
manishkumarm
Electrical Control Panels | Variable Frequency Drives | Hazardous Location Pa...
Electrical Control Panels | Variable Frequency Drives | Hazardous Location Pa...
Jazz Matharu
Mais conteúdo relacionado
Mais procurados
Copper Cable Lugs and Terminals Catalogue
Copper Cable Lugs and Terminals Catalogue
Grey Hawk Electricals
Single line diagram ats apfc
Single line diagram ats apfc
Sajeewa Lakmal
ppt on industrial training of final year studen from ptcul 132kv substation ...
ppt on industrial training of final year studen from ptcul 132kv substation ...
surendra rawat
220kv substation
220kv substation
Anbarasu Balakrishnan
Cpc 100 user manual
Cpc 100 user manual
SARAVANAN A
220 66 kv nrs sub report
220 66 kv nrs sub report
Mayur Dhanaji Rane
PLC and Industrial Automation - Technology Overview
PLC and Industrial Automation - Technology Overview
Nereus Fernandes
Gis basics
Gis basics
Satish Kumar
SPS Heat Shrink Cable Terminations 11kV 33kV - Minimum Air Clearances (Cable...
SPS Heat Shrink Cable Terminations 11kV 33kV - Minimum Air Clearances (Cable...
Thorne & Derrick International
MCC PANEL WIRING, GA and BOM Sample
MCC PANEL WIRING, GA and BOM Sample
Shashi Kant
UHF partial discharge detection system for GIS Application guide for sensitiv...
UHF partial discharge detection system for GIS Application guide for sensitiv...
Power System Operation
Plc project report
Plc project report
Umair Rashid
220 KV Switchyard general overview
220 KV Switchyard general overview
Thien Huynh
SWITCHYARD EQUIPMENTS & PROTECTION SYSTEMS
SWITCHYARD EQUIPMENTS & PROTECTION SYSTEMS
Partha Parida
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...
AKBAR TRADING
Schneider RM6 - MV Medium Voltage Compact Switchboard (Ring Main Unit) up to ...
Schneider RM6 - MV Medium Voltage Compact Switchboard (Ring Main Unit) up to ...
Thorne & Derrick International
Photovoltaic IV Curve Analysis
Photovoltaic IV Curve Analysis
Dimas Kaharudin
Pfisterer Cable Fittings 11kV 33kV 52kV - Pfisterer MV-CONNEX Inner Cone Plug...
Pfisterer Cable Fittings 11kV 33kV 52kV - Pfisterer MV-CONNEX Inner Cone Plug...
Thorne & Derrick International
Presentacion arco interno
Presentacion arco interno
jahkurt
Honeywell PLC TRAINING GUIDE created by deepak gorai
Honeywell PLC TRAINING GUIDE created by deepak gorai
DEEPAK GORAI
Mais procurados
(20)
Copper Cable Lugs and Terminals Catalogue
Copper Cable Lugs and Terminals Catalogue
Single line diagram ats apfc
Single line diagram ats apfc
ppt on industrial training of final year studen from ptcul 132kv substation ...
ppt on industrial training of final year studen from ptcul 132kv substation ...
220kv substation
220kv substation
Cpc 100 user manual
Cpc 100 user manual
220 66 kv nrs sub report
220 66 kv nrs sub report
PLC and Industrial Automation - Technology Overview
PLC and Industrial Automation - Technology Overview
Gis basics
Gis basics
SPS Heat Shrink Cable Terminations 11kV 33kV - Minimum Air Clearances (Cable...
SPS Heat Shrink Cable Terminations 11kV 33kV - Minimum Air Clearances (Cable...
MCC PANEL WIRING, GA and BOM Sample
MCC PANEL WIRING, GA and BOM Sample
UHF partial discharge detection system for GIS Application guide for sensitiv...
UHF partial discharge detection system for GIS Application guide for sensitiv...
Plc project report
Plc project report
220 KV Switchyard general overview
220 KV Switchyard general overview
SWITCHYARD EQUIPMENTS & PROTECTION SYSTEMS
SWITCHYARD EQUIPMENTS & PROTECTION SYSTEMS
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...
Schneider RM6 - MV Medium Voltage Compact Switchboard (Ring Main Unit) up to ...
Schneider RM6 - MV Medium Voltage Compact Switchboard (Ring Main Unit) up to ...
Photovoltaic IV Curve Analysis
Photovoltaic IV Curve Analysis
Pfisterer Cable Fittings 11kV 33kV 52kV - Pfisterer MV-CONNEX Inner Cone Plug...
Pfisterer Cable Fittings 11kV 33kV 52kV - Pfisterer MV-CONNEX Inner Cone Plug...
Presentacion arco interno
Presentacion arco interno
Honeywell PLC TRAINING GUIDE created by deepak gorai
Honeywell PLC TRAINING GUIDE created by deepak gorai
Destaque
PLC based load managment
PLC based load managment
manishkumarm
Electrical Control Panels | Variable Frequency Drives | Hazardous Location Pa...
Electrical Control Panels | Variable Frequency Drives | Hazardous Location Pa...
Jazz Matharu
PLC Circuit Design And Basic Programming By Manish kumar
PLC Circuit Design And Basic Programming By Manish kumar
manishkumarm
Panel designing
Panel designing
AKANSHA GURELE
Report - PLC Based Electrical Load Management System
Report - PLC Based Electrical Load Management System
Ijlal Siddiqui
Ppt of PGCIL by d.p.yadav( 91 8432379261)
Ppt of PGCIL by d.p.yadav( 91 8432379261)
Dharmpal Yadav
Agent based Load Management for Microgrid
Agent based Load Management for Microgrid
Mohamed Abbas
Environmental Protectionand Industrial Policy1(Ab)
Environmental Protectionand Industrial Policy1(Ab)
abtabussam
Tourism potential of hazara region A Presentation By Mr Allah Dad Khan Agri...
Tourism potential of hazara region A Presentation By Mr Allah Dad Khan Agri...
Mr.Allah Dad Khan
Lahore Garment City Pakistan Textile Export Import Opportunity
Lahore Garment City Pakistan Textile Export Import Opportunity
Hassan Yousufzai
Retail sector-report
Retail sector-report
Muhammad Luqman Noor
Lahore City Pakistan Economy view
Lahore City Pakistan Economy view
Layan Kanishaka Asiri Wijekoon
Tourism sites in pakistan
Tourism sites in pakistan
fauzia samreen
Business planEntrepreneurship Business Plan of Travel Agency for local and in...
Business planEntrepreneurship Business Plan of Travel Agency for local and in...
AFAAQSALEEM
Test Bench
Test Bench
Muhammad Sarfraz
PI&T Conceptual Drawing
PI&T Conceptual Drawing
Muhammad Sarfraz
Industrial Automation Using B&R PLC.
Industrial Automation Using B&R PLC.
Government Engineering College, Gandhinagar
Atlas Honda Buner
Atlas Honda Buner
Muhammad Sarfraz
ITM_KDF-TPU600
ITM_KDF-TPU600
Muhammad Sarfraz
Background of Pakistan Economy a historical perspective
Background of Pakistan Economy a historical perspective
Ayesha Majid
Destaque
(20)
PLC based load managment
PLC based load managment
Electrical Control Panels | Variable Frequency Drives | Hazardous Location Pa...
Electrical Control Panels | Variable Frequency Drives | Hazardous Location Pa...
PLC Circuit Design And Basic Programming By Manish kumar
PLC Circuit Design And Basic Programming By Manish kumar
Panel designing
Panel designing
Report - PLC Based Electrical Load Management System
Report - PLC Based Electrical Load Management System
Ppt of PGCIL by d.p.yadav( 91 8432379261)
Ppt of PGCIL by d.p.yadav( 91 8432379261)
Agent based Load Management for Microgrid
Agent based Load Management for Microgrid
Environmental Protectionand Industrial Policy1(Ab)
Environmental Protectionand Industrial Policy1(Ab)
Tourism potential of hazara region A Presentation By Mr Allah Dad Khan Agri...
Tourism potential of hazara region A Presentation By Mr Allah Dad Khan Agri...
Lahore Garment City Pakistan Textile Export Import Opportunity
Lahore Garment City Pakistan Textile Export Import Opportunity
Retail sector-report
Retail sector-report
Lahore City Pakistan Economy view
Lahore City Pakistan Economy view
Tourism sites in pakistan
Tourism sites in pakistan
Business planEntrepreneurship Business Plan of Travel Agency for local and in...
Business planEntrepreneurship Business Plan of Travel Agency for local and in...
Test Bench
Test Bench
PI&T Conceptual Drawing
PI&T Conceptual Drawing
Industrial Automation Using B&R PLC.
Industrial Automation Using B&R PLC.
Atlas Honda Buner
Atlas Honda Buner
ITM_KDF-TPU600
ITM_KDF-TPU600
Background of Pakistan Economy a historical perspective
Background of Pakistan Economy a historical perspective
Semelhante a Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing
Amp servo products_brochure
Amp servo products_brochure
Electromate
Arauco ServoSistemas Presentation
Arauco ServoSistemas Presentation
Eduardo Condemarin
Project #1 - Water Pumping Station - Switchboard Upgrade
Project #1 - Water Pumping Station - Switchboard Upgrade
David List
Appron feeder common ckt-diagram
Appron feeder common ckt-diagram
yogagivananda
Advanced motion controls_azbdc10a4ic
Advanced motion controls_azbdc10a4ic
Electromate
Advanced motion controls zdcr300ee12a8ldc
Advanced motion controls zdcr300ee12a8ldc
Electromate
Be siemens price list 03 02-2012
Be siemens price list 03 02-2012
bhumi_ent2007
Lv power distribution_products_pricelist_w.e.f_1st_oct_2016
Lv power distribution_products_pricelist_w.e.f_1st_oct_2016
Maxpromotion
S 1647
S 1647
George Romero Tadeu Carvalho Nunes
1500V String Inverter Utility PV System Solution 2021.pdf
1500V String Inverter Utility PV System Solution 2021.pdf
goangagoanga99
Advanced motion controls 10a8dd
Advanced motion controls 10a8dd
Electromate
Dienhathe.com lv72 k-en_xx_2005
Dienhathe.com lv72 k-en_xx_2005
Dien Ha The
Advanced motion controls 10a8
Advanced motion controls 10a8
Electromate
PLC-updated.pptx
PLC-updated.pptx
Sachiv3
dn542fa_web
dn542fa_web
Yingyi Yan
qsfp-40g-5m-aoc-cable-data-sheet-171014.pdf
qsfp-40g-5m-aoc-cable-data-sheet-171014.pdf
GLsun Mall
QSFP-40G-A05-T01#171014.pdf
QSFP-40G-A05-T01#171014.pdf
GLsun Mall
qsfp-40g-3m-active-optical-cable-data-sheet-171013.pdf
qsfp-40g-3m-active-optical-cable-data-sheet-171013.pdf
GLsun Mall
QSFP-40G-A03-T01#171013.pdf
QSFP-40G-A03-T01#171013.pdf
GLsun Mall
1429498303wpdm product print 4 201408r
1429498303wpdm product print 4 201408r
google.com
Semelhante a Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing
(20)
Amp servo products_brochure
Amp servo products_brochure
Arauco ServoSistemas Presentation
Arauco ServoSistemas Presentation
Project #1 - Water Pumping Station - Switchboard Upgrade
Project #1 - Water Pumping Station - Switchboard Upgrade
Appron feeder common ckt-diagram
Appron feeder common ckt-diagram
Advanced motion controls_azbdc10a4ic
Advanced motion controls_azbdc10a4ic
Advanced motion controls zdcr300ee12a8ldc
Advanced motion controls zdcr300ee12a8ldc
Be siemens price list 03 02-2012
Be siemens price list 03 02-2012
Lv power distribution_products_pricelist_w.e.f_1st_oct_2016
Lv power distribution_products_pricelist_w.e.f_1st_oct_2016
S 1647
S 1647
1500V String Inverter Utility PV System Solution 2021.pdf
1500V String Inverter Utility PV System Solution 2021.pdf
Advanced motion controls 10a8dd
Advanced motion controls 10a8dd
Dienhathe.com lv72 k-en_xx_2005
Dienhathe.com lv72 k-en_xx_2005
Advanced motion controls 10a8
Advanced motion controls 10a8
PLC-updated.pptx
PLC-updated.pptx
dn542fa_web
dn542fa_web
qsfp-40g-5m-aoc-cable-data-sheet-171014.pdf
qsfp-40g-5m-aoc-cable-data-sheet-171014.pdf
QSFP-40G-A05-T01#171014.pdf
QSFP-40G-A05-T01#171014.pdf
qsfp-40g-3m-active-optical-cable-data-sheet-171013.pdf
qsfp-40g-3m-active-optical-cable-data-sheet-171013.pdf
QSFP-40G-A03-T01#171013.pdf
QSFP-40G-A03-T01#171013.pdf
1429498303wpdm product print 4 201408r
1429498303wpdm product print 4 201408r
Mais de Muhammad Sarfraz
HMI_1
HMI_1
Muhammad Sarfraz
PLC_1
PLC_1
Muhammad Sarfraz
CPU
CPU
Muhammad Sarfraz
SIEMENS Certification
SIEMENS Certification
Muhammad Sarfraz
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Muhammad Sarfraz
xxxQxxx Quotation Estimate for Electrical Work of Poultry Processing Plant
xxxQxxx Quotation Estimate for Electrical Work of Poultry Processing Plant
Muhammad Sarfraz
merged
merged
Muhammad Sarfraz
Visio-Drawing
Visio-Drawing
Muhammad Sarfraz
BMS-walls
BMS-walls
Muhammad Sarfraz
OutE62
OutE62
Muhammad Sarfraz
OLV1 (Short-Circuit Analysis) on Wapda
OLV1 (Short-Circuit Analysis) on Wapda
Muhammad Sarfraz
OLV1 (Load Flow Analysis) in Synch Mod
OLV1 (Load Flow Analysis) in Synch Mod
Muhammad Sarfraz
Visio-Tobacco Box Tilt Unit
Visio-Tobacco Box Tilt Unit
Muhammad Sarfraz
HMI_1
HMI_1
Muhammad Sarfraz
ActiveReports Document
ActiveReports Document
Muhammad Sarfraz
Plishing Plant Drawing
Plishing Plant Drawing
Muhammad Sarfraz
merged
merged
Muhammad Sarfraz
LOGO!Soft Comfort - Condensate Water Tank
LOGO!Soft Comfort - Condensate Water Tank
Muhammad Sarfraz
Mais de Muhammad Sarfraz
(18)
HMI_1
HMI_1
PLC_1
PLC_1
CPU
CPU
SIEMENS Certification
SIEMENS Certification
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
xxxQxxx Quotation Estimate for Electrical Work of Poultry Processing Plant
xxxQxxx Quotation Estimate for Electrical Work of Poultry Processing Plant
merged
merged
Visio-Drawing
Visio-Drawing
BMS-walls
BMS-walls
OutE62
OutE62
OLV1 (Short-Circuit Analysis) on Wapda
OLV1 (Short-Circuit Analysis) on Wapda
OLV1 (Load Flow Analysis) in Synch Mod
OLV1 (Load Flow Analysis) in Synch Mod
Visio-Tobacco Box Tilt Unit
Visio-Tobacco Box Tilt Unit
HMI_1
HMI_1
ActiveReports Document
ActiveReports Document
Plishing Plant Drawing
Plishing Plant Drawing
merged
merged
LOGO!Soft Comfort - Condensate Water Tank
LOGO!Soft Comfort - Condensate Water Tank
Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing
1.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 1/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Title Page D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 Electrical Schematic Drawing for Efficient Load Management System (ELMS) With ATS_AMF Generator Control UNILEVER HPC FACTORY PAKISTAN Ltd. WATT N VOLT Industrial Automation & Engineering
2.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 2/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Main Incoming Supply Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 EARTH LEAKAGE PROTECTION CIRCUIT BREAKER (RCCB) (Q) MAIN CIRCUIT BREAKER (MCCB) Magnetic & Thermal Protection. (Q) Miniature Circuit Breaker (F) Magnetic Contactor (KM) Relay or Contactor Coil (KA) Panel Light (H) Panel cooling Fan (V) Socket outlet 230vac 1 phase (P) Indication Light (H) Panel Door Switch (S) <I <I <I Normally Close Contact Normally Open Contact 123 Line up Terminal (X) 123 Fusible Terminal (X) PLC Module Terminals LEGEND 9 CODING 12 R 1 SEQUENCE OF NUMBRING/Column FUNCTION SHEET NUMBER Q = CIRCUIT BREAKER M = CONTACTOR R = AUXILIARY RELAY H = SIGNAL LIGHT I = PLC INPUT Q = PLC OUTPUT WIRE COLORS 3 Phase Supply 415VAC = Black Earth = Green/Yellow Control Supply 24VDC = Blue Analog/Digital Signal = White/Blue Interlocking = Orange COMPONENTS ACB/MCCB = SCHENIDER CONTROL RELAYS = OMRON TERMINAL BLOCKS = LEGRAND CONTACTOR = SCHENIDER ANALYZER = JANITZA CURRENT TRANSDUCER = VERIS CT’s = EFEN
3.
PANEL FRONT VIEW 4400.00 0 Company
Name:Client Name: WATT N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 3/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Panel External Layout D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 6“ Fan Filter 2100 100 5H3.2 5H3 5H3.1 5H7 5H7.15H7.2 5EM8 6“ Fan Filter ACB 1250A 6“ Fan Filter 6“ Fan Filter ACB 1250A 6“ Fan Filter 6“ Fan Filter 6“ Fan Filter 6“ Fan Filter 800.00 800.00 1000.00 800.00 6“ Fan Filter 6“ Fan Filter 1000.00 DSE7320 KTP600 PN 5ES1 5H8.2 5H8 5H8.1 5Q7 5Q2 5U5 14A1 Maintenance Alarm Reset 5S4
4.
COMPONENTS ARRANGEMENT 0 Company Name:Client
Name: WATT N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 4/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Panel Internal Layout D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 2000 715 100 715 915 715 Mains Incoming 3~415vac Supply ACB 1250A NW12H1 40x60 40x60 40x60 40x60 40x60 Generator Incoming 3~415vac Supply ACB 1250A NW12H1 6F6 40x60 40x60 6F45F7 5F8 40x60 40x60 15F0 40x60 40x60 40x60 40x60 60x60 60x60 60x60 915 8CT8.1 8CT8 8CT8.2 9CT1.1 9CT1 9CT1.2 9CT8.1 9CT8 9CT8.2 LC1F265 LC1F265 40x60 40x60 40x60 40x60 40x60 NSX100F NSX100F NSX100F NSX100F 60x60 NSX100F 60x60 NSX100F NSX100F 60x60 60x60 40x60 60x60 60x60 60x60 60x60 250.00 60x60 220.00 Interposing Relay’s 14F0 40x60 220.00 40x60 220.00 Interposing Relay’s PLC S7-1200 Rack 220.00 60x60 60x60 595.00 Battery Charger 7F3 7F0 Power Pack Charger 620.00 7P7 TENBY PLC Bypass Switch 40x60 40x60 475.00 620.00 3975.00 5Q7 5Q2 X00E X00N 5F9 CT 1200/5A CT 1200/5A CT 1200/5A CT 1200/5A CT 1200/5A CT 1200/5A5CT9 5CT9.1 5CT9.2 5CT10.2 5CT10.1 5CT10 6U7 6BT5 X200 X100 5F3 5F6 6F3 6F5 6F1 6F65F1 X00E X00N 5R4 5R5 5R2 5R2.1 5R3 6U1 7F87F7 7TH3 14S0 16R2 X500 X300 X444 X400 X600 14N0 14N1 14N2 14N2.1 14N3 14N4 14N5 14N6 14N7 14N8 14N9 14N9.1 X300 16R2.1 16R3 16R3.1 16R4 16R4.1 16R5 16R5.1 16R6 16R6.1 18R1 18R1.1 18R2 18R2.1 18R3 18R3.1 18R4 18R4.1 18R5 18R5.1 18R6 18R6.1 18R7 18R7.1 18R8 18R8.1 20R1 20R1.1 10K1 10K4 7S0 11Q1 11Q4 11Q8 12Q1 13Q1 13Q4 13Q8 LC1F400 LC1F400LC1F265 8K1 8K49K4 NSX400N NSX400N NSX250F 8Q1 8Q4 9Q4 8CT1.1 8CT1 8CT1.2 8CT4.1 8CT4 8CT4.2 9CT4.1 9CT4 9CT4.2 LC1F400 LC1F400LC1F265 8K8 9K19K8 NSX400N NSX400N NSX250F 8Q8 9Q1 9Q8 14R1 14R1.1 14R1.2 14R1.3 40x60 40x60 40x60 40x60 LC1D115 LC1D115 LC1D115 LC1D115 11K1 11K4 11K8 12K1 11CT1.1 11CT1 11CT1.2 11CT4.1 11CT411CT4.2 11CT8.1 11CT8 11CT8.2 12CT1.1 12CT1 12CT1.2 13CT1.1 13CT1 13CT1.2 13CT4.1 13CT4 13CT4.1 13CT8.1 13CT8 13CT8.2 LC1D80 LC1D65 LC1D25 13K1 13K4 13K8 10CT1.1 10CT1 10CT1.2 10CT4.1 10CT4 10CT4.2 10Q1 NSX250F NSX250F 10Q4 25x60 X666
5.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 5/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Mains & Generator Power and Control Supply Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 Generator Incoming Supply 3~ 415Vac Neutral + Earth GROUND NEUTRAL W V U N E NE N PE 51 52 53 55 54 43 44 45 46 41 42 39 40 47 48 49 50 7 24 22 23 27 25 269 10 1166 67 863 64 6560 61 6218 19 1516 171 2 3 4 5 DSE-7320 V12.0 A B SCR USB Programming Port L H SCR Engine ECU Plant +VE 4 FET Output 8 Digital Input -VE Battery -VE +VE FUEL CRANK OIL WATER FUEL FLEXIBLE SENDER COMMON RS-485 RS232 CT1 CT2 CT3 N COM L1 L2 L3 N GEN. CURRENT GEN. VOLTS GENERATOR ACB CLOSE MAINS ACB CLOSE 28 29 30 + DSE NET SPEED - SCR R S T N MAINS VOLTS SCR MPU 21 22 + - 24VENGINE BATTERY 2A 5F2 6 CHG.ALT. 5A 5F3 5ES1 Charge ALT. WL A1 A2 5R2.1 (1) (3) 4X100 A1 A2 5R3 (1) (3) X100 5 A1 A2 5R2 LOWOILPRESSURE HIGHCOOLANTTEMP. FUELLEVELSENDER FUELLEVELSENDER -VEINPUTA -VEINPUTB -VEINPUTC -VEINPUTD -VEINPUTE -VEINPUTF -VEINPUTG -VEINPUTH MaintenanceAlarmReset USERCONFIGURABLE USERCONFIGURABLE USERCONFIGURABLE USERCONFIGURABLE USERCONFIGURABLE USERCONFIGURABLE USERCONFIGURABLE USERCONFIGURABLE+VEOUTPUTE USERCONFIGURABLE+VEOUTPUTF USERCONFIGURABLE+VEOUTPUTG USERCONFIGURABLE+VEOUTPUTH L1 L2 L3 2124C1C21112A1A2D1D2 B1B2 4284823431 4144 Mains Incoming Supply 3~ 415Vac Neutral + Earth R S T NEUTRAL GROUND X100 16 17 18 196X1001X100 1A 2X100 2A 5Q7 Mains ACB 1250A MN Under Voltage Trip MCH Spring Charging Motor XF ACB Shunt Close MX AUX. OF1 AUX. OF2 AUX. OF3 AUX. SDE AUX. OF4 ACB Shunt Open 2124C1C21112A1A2D1D2 B1B2 4284823431 4144 5Q2 Generator ACB 1250A MN Under Voltage Trip MCH Spring Charging Motor XF ACB Shunt Close MX AUX. OF1 AUX. OF2 AUX. OF3 AUX. SDE AUX. OF4 ACB Shunt Open L1 L2 L3 Mechanical Interlock 24vdc 24vdc 24vdc 5H8 5H8.25H8.1 X1 X2 X1 X2 X1 X2 +24vdc 2X200 1 -24vdc From Power Pack Battery ACB Trip ACB ON/OFFACB Trip ACB ON/OFF 5H3 5H3.25H3.1 X1 X2 X1 X2 X1 X2 +24vdc 2X200 1 -24vdc From Power Pack Battery 2A 5F0 1200/5A 5CT0 1200/5A 5CT0.1 1200/5A 5CT0.2 (51) (52) (53) (54) 3A 5F1 Neutral (73) L1 L2 L3 Neutral (75) (83) (85) 21 22 5ES1 (70) X00NX00E1 2 3 4 5 1 2 3 4 X00EX00N1 2 3 4 5 1 2 3 4 5 In Generator Panel In Generator Panel In Mains Panel In Mains Panel 5 1 X00N 2 X00N A2 A1 5R4 220vac (5) (6) 5R5 A2 A1 5R5 220vac (5) (6) 5R4 Electrical Interlock 2A 5F9 Neutral X00N 21 22 5ES1 4A 5F8 (45) (44) (43) (46) (42) (39) (47) (48) (49) (3) (1) (4) 5R4 (3) (1) (4) 5R5 1 (8) (11) 5R5 (8) (11)5R4 (40) (40) (2)(-) (3) (6) (4) (5) (16) (17) (18) (19) (15) (4A) (5A)(-) (-) (-) (70) (70) (70)(71) (41) (76)(74) (77) (78) (79) (77)(80) (-) (41) (41) (41) (40) (40) (81) (81) (81) (81)(82) (84) (86) (87) (87)(88) (89) (90) (-) (70) (81) (42A) (39A) 4 1 2 3 VN V1 V2 V3 5 6 7 8 9 10 I1 I2 I3 UMG-96L Digital Power Analyzer Measuring Voltage Measuring Current Janitza 5EM8 1200/5A 5CT9.21200/5A 5CT9.11200/5A 5CT9 2A 5F7 (91) (92) (93) 5H7 X1 X2 5H7.1 X1 X2 5H7.2 X1 X2 120 Terminating Resistor for trouble- free data traffic To page 6.7 5U5 5R2.1 (8) (5) 21 PFI Signal To page 19.9 (I13.7) X100 24 22 23 13 14 5S4 5ES1.1 At Gen. 21 22
6.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 6/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Battery Chargers Power and Control Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/7.0 L2/7.0 L3/7.0 N PE L1/5.9 L2/5.9 L3/5.9 N/5.9 PE/5.9 + - 12VENGINE BATTERY + - 12VENGINE BATTERY NTC DSE-9470 MKII V3.1 OP- OP+ NO COM NC NTC LK1 LK1 USB Programming Port N L E SCR A BCF DSE-9701 OP- OP+ CF E N LBOOST 10A 6F4 6A 6F3 16A 6F5 6A 6F0 + - 12VENGINE BATTERY -VEDCOUTPUT +VEDCOUTPUT LINK FOR BOOST CHARGE CLOSE UPON CHARGER FAILURE Input Supply 110…...230vac @ 1.5A Input Supply 110…...230vac @ 2.3A -VEDCOUTPUT +VEDCOUTPUT CHARGER FAILURE RELAY PT1000 TEMPERATURE SENSOR DIGITAL INPUT SELECTION 12 OR 24VDC OUTPUT RS-485 I4.0 PLC input channel at page 15.8 I4.1 PLC input channel at page 15.8 16A 6F1 1 2 3 4 5 X100 1 2 3 4 5 X100 +VE 24VDC -VE 24VDC 16A 6F6 1 2 3 4 5 X200 1 2 3 4 5 X200 +VE 24VDC -VE 24VDC From 5U5 page 5.3 To page 14.1 6U1 6U7 (94) (95) (96) (97) (96) (97) (108) (I4.0) (100) (101) (102) (103) (104) (105) (106) (107) (107)(106) (108) (109) -VE (I4.1) (108) -VE 6BT1 6BT5 (8) (5) 5R2 (1) (4) + - 12VENGINE BATTERY Power Pack Battery Charger for PLC/HMI Control Supply Generator Battery Charger for ATS/AMF Control Supply
7.
220VAC 7F3 (4A) 0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 7/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Panel Cooling Fan, Light and Socket Power Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/8.0 L2/8.0 L3/8.0 N PE L1/6.9 L2/6.9 L3/6.9 N/6.9 PE/6.9 7777HHHH0000 7777SSSS0000 PANEL DOOR SWITCH Panel Light 7F0 (3A) 7TH3 1 2 Panel Cooling Fan PE PE 7777CFCFCFCF1111....1111 7777CFCFCFCF1111 Panel Cooling Fan PE PE 7777CFCFCFCF3333....1111 7777CFCFCFCF3333 Panel Cooling Fan PE PE 7777CFCFCFCF2222....1111 7777CFCFCFCF2222 Panel Cooling Fan PE PE 7777CFCFCFCF4444....1111 7777CFCFCFCF4444 Panel Cooling Fan PE PE 7777CFCFCFCF5555....1111 7777CFCFCFCF5555 7F7 (3A) 7P7 Computer Socket (112) (113) (114) (115) (117) (116) (117)(116) (117)(116) (117)(116) (117)(116) (117)(116) (116) (117) (118) (119) 7F8 (10A) X500 3 4 5 6 7 In PLC Panel (501) 21 X500 3 4 5 6 7 (500) 21
8.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 8/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Outgoing Feeder Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/7.0 L2/7.0 L3/7.0 N PE L1/7.9 L2/7.9 L3/7.9 N/5.9 PE/5.9 109/6.7 109/9.0 108/6.7 108/9.0 8Q1 8K1 I>I>I> (21) (22) FEEDER CIRCUIT 220KW NSX400N ML2.3 Molded Case Circuit Breaker with Adjustable Rating 160-400A Triple Pole 50kA LC1F400 Magnetic Contactor 400A_220KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB A1 A2 Bungalow 9-15 (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Outgoing Feeder Circuit 220KW for Bungalow 9-15 (L1) (L2) (L3) I0.2 (109) (108) A1 A2 (11) 16R2 (14) Q0.0 (109) (120) (108) I0.0 I0.1 (E) R Y B N E (N) (109) (109) 400/4...20mA 8CT1 + PIW128To PLC AI Channel At page 21.1 400/4...20mA + To PLC AI Channel At page 21.2 To PLC AI Channel At page 21.3 (109) (109) 8CT1.1 PIW130 400/4...20mA 8CT1.2 + PIW132 8Q4 8K4 I>I>I> (21) (22) FEEDER CIRCUIT 220KW NSX400N ML2.3 Molded Case Circuit Breaker with Adjustable Rating 160-400A Triple Pole 50kA LC1F400 Magnetic Contactor 400A_220KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB A1 A2 SPARE (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Spare (L1) (L2) (L3) (109) A1 A2 (11) (14) Q0.1 (109) (121) I0.3 I0.4 (E) R Y B N E (N) (109) (109) 400/4...20mA 8CT4 + PIW134To PLC AI Channel At page 21.4 400/4...20mA + To PLC AI Channel At page 21.5 To PLC AI Channel At page 21.6 (109) (109) 8CT4.1 PIW136 400/4...20mA 8CT4.2 + PIW138 8Q8 8K8 I>I>I> (21) (22) FEEDER CIRCUIT 220KW NSX400N ML2.3 Molded Case Circuit Breaker with Adjustable Rating 160-400A Triple Pole 50kA LC1F400 Magnetic Contactor 400A_220KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB A1 A2 M-TYPE (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Outgoing Feeder Circuit 220KW for M-Type (L1) (L2) (L3) (109) A1 A2 (11) (14) Q0.2 (109) (122) I0.6 I0.7 (E) R Y B N E (N) (109) (109) 400/4...20mA 8CT8 + PIW140To PLC AI Channel At page 21.7 400/4...20mA + To PLC AI Channel At page 21.8 To PLC AI Channel At page 22.1 (109) (109) 8CT8.1 PIW142 400/4...20mA 8CT8.2 + PIW144 OF SD OF SD OF SD X500 1 (501) (500) X500 1 (108) (108) X500 1 (501) (500) X500 1 16R2.1 I0.5 (108) (108) X500 2 (501) (500) X500 2 I1.0 16R3
9.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 9/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Outgoing Feeder Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/10.0 L2/10.0 L3/10.0 N PE L1/8.9 L2/8.9 L3/8.9 N/8.9 PE/8.9 109/8.9 109/10.0 108/8.9 108/10.0 9Q1 9K1 I>I>I> (21) (22) FEEDER CIRCUIT 220KW NSX400N ML2.3 Molded Case Circuit Breaker with Adjustable Rating 160-400A Triple Pole 50kA LC1F400 Magnetic Contactor 400A_220KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB A1 A2 C-TYPE (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Outgoing Feeder Circuit 220KW for C-Type (L1) (L2) (L3) (109) A1 A2 (11) (14) Q0.3 (109) (123) I1.1 I1.2 (E) R Y B N E (N) (109) (109) 400/4...20mA 9CT1 + PIW146To PLC AI Channel At page 22.2 400/4...20mA + To PLC AI Channel At page 22.3 To PLC AI Channel At page 22.4 (109) (109) 9CT9.1 PIW148 400/4...20mA 9CT1.2 + PIW150 OF SD 9Q4 9K4 I>I>I> (21) (22) FEEDER CIRCUIT 140KW NSX250F TM-D Molded Case Circuit Breaker with Adjustable Rating 175-250A Triple Pole 36kA LC1F265 Magnetic Contactor 265A_140KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB A1 A2 A-TYPE (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Outgoing Feeder Circuit 140KW for A-Type (L1) (L2) (L3) (109) A1 A2 (11) (14) Q0.4 (109) (124) I1.4 I1.5 (E) R Y B N E (N) (109) (109) 250/4...20mA 9CT4 + PIW152To PLC AI Channel At page 22.5 250/4...20mA + To PLC AI Channel At page 22.6 To PLC AI Channel At page 22.7 (109) (109) 9CT4.1 PIW154 250/4...20mA 9CT4.2 + PIW156 OF SD 9Q8 9K8 I>I>I> (21) (22) A1 A2 Bungalow 4-8 (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Outgoing Feeder Circuit 140KW for Bungalow 4-8 (L1) (L2) (L3) (109) A1 A2 (11) (14) Q0.5 (109) (125) I8.1 I8.2 (E) R Y B N E (N) (109) (109) 250/4...20mA 9CT8 + PIW158To PLC AI Channel At page 22.8 250/4...20mA + To PLC AI Channel At page 23.1 To PLC AI Channel At page 23.2 (109) (109) 9CT8.1 PIW160 250/4...20mA 9CT8.2 + PIW162 OF SD FEEDER CIRCUIT 140KW NSX250F TM-D Molded Case Circuit Breaker with Adjustable Rating 175-250A Triple Pole 36kA LC1F265 Magnetic Contactor 265A_140KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB (108) (108) X500 3 (501) (500) X500 3 16R4 I8.0 (108) (108) X500 2 (501) (500) X500 2 16R3.1 I1.3 (108) (108) X500 3 (501) (500) X500 3 16R4.1 I8.3
10.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 10/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Outgoing Feeder Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/11.0 L2/11.0 L3/11.0 N PE L1/9.0 L2/9.0 L3/9.0 N/9.0 PE/9.0 109/9.0 109/11.0 108/9.0 108/11.0 10Q1 10K1 I>I>I> (21) (22) A1 A2 SPARE (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Outgoing Feeder Circuit 140KW for Spare (L1) (L2) (L3) (109) A1 A2 (11) (14) Q0.6 (109) (126) I8.4 I8.5 (E) R Y B N E (N) (109) (109) 250/4...20mA 10CT1 + PIW164To PLC AI Channel At page 23.3 250/4...20mA + To PLC AI Channel At page 23.4 To PLC AI Channel At page 23.5 (109) (109) 10CT1.2 PIW166 250/4...20mA 10CT1.3 + PIW168 OF SD FEEDER CIRCUIT 140KW NSX250F TM-D Molded Case Circuit Breaker with Adjustable Rating 175-250A Triple Pole 36kA LC1F265 Magnetic Contactor 265A_140KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB 10Q4 10K4 I>I>I> (21) (22) A1 A2 SPARE (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) Outgoing Feeder Circuit 140KW for Spare (L1) (L2) (L3) (109) A1 A2 (11) (14) Q0.7 (109) (127) I8.7 I9.0 (E) R Y B N E (N) (109) (109) 250/4...20mA 10CT4 + PIW170To PLC AI Channel At page 23.6 250/4...20mA + To PLC AI Channel At page 23.7 To PLC AI Channel At page 23.8 (109) (109) 10CT4.1 PIW172 250/4...20mA 10CT4.2 + PIW174 OF SD FEEDER CIRCUIT 140KW NSX250F TM-D Molded Case Circuit Breaker with Adjustable Rating 175-250A Triple Pole 36kA LC1F265 Magnetic Contactor 265A_140KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB (108) (108) X500 4 (501) (500) X500 4 I8.6 16R5 (108) (108) X500 4 (501) (500) X500 4 16R5.1 I9.1
11.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 11/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Outgoing Feeder Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/12.0 L2/12.0 L3/12.0 N PE L1/10.0 L2/10.0 L3/10.0 N/10.9 PE/10.9 109/10.9 109/12.0 108/10.9 108/12.0 11Q1 11K1 I>I>I> (21) (22) A1 A2 Bungalow-3 (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) (L1) (L2) (L3) (109) A1 A2 (11) (14) Q1.0 (109) (128) I9.2 I9.3 (E) R Y B N E (N) (109) (109) 100/4...20mA 11CT1 + PIW176To PLC AI Channel At page 24.1 100/4...20mA + To PLC AI Channel At page 24.2 To PLC AI Channel At page 24.3 (109) (109) 11CT1.1 PIW178 100/4...20mA 11CT1.2 + PIW180 OF SD FEEDER CIRCUIT 59KW NSX100F TM-D Molded Case Circuit Breaker with Adjustable Rating 70-100A Triple Pole 36kA LC1D115 Magnetic Contactor 115A_59KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB Outgoing Feeder Circuit 59KW for Bungalow-3 11Q4 11K4 I>I>I> (21) (22) A1 A2 Bungalow-2 (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) (L1) (L2) (L3) (109) A1 A2 (11) (14) Q1.1 (109) (129) I9.5 I9.6 (E) R Y B N E (N) (109) (109) 100/4...20mA 11CT4 + PIW182To PLC AI Channel At page 24.4 100/4...20mA + To PLC AI Channel At page 24.5 To PLC AI Channel At page 24.6 (109) (109) 11CT4.1 PIW184 100/4...20mA 11CT4.2 + PIW186 OF SD FEEDER CIRCUIT 59KW NSX100F TM-D Molded Case Circuit Breaker with Adjustable Rating 70-100A Triple Pole 36kA LC1D115 Magnetic Contactor 115A_59KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB Outgoing Feeder Circuit 59KW for Bungalow-2 11Q8 11K8 I>I>I> (21) (22) A1 A2 Tubewell (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) (L1) (L2) (L3) (109) A1 A2 (11) (14) Q8.0 (109) (130) I12.0 I12.1 (E) R Y B N E (N) (109) (109) 100/4...20mA 11CT8 + PIW188To PLC AI Channel At page 24.7 100/4...20mA + To PLC AI Channel At page 24.8 To PLC AI Channel At page 25.1 (109) (109) 11CT8.1 PIW190 100/4...20mA 11CT8.2 + PIW192 OF SD FEEDER CIRCUIT 59KW NSX100F TM-D Molded Case Circuit Breaker with Adjustable Rating 70-100A Triple Pole 36kA LC1D115 Magnetic Contactor 115A_59KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB Outgoing Feeder Circuit 59KW for Tubewell (108) (108) X500 5 (501) (500) X500 5 (108) (108) X500 5 (501) (500) X500 5 (108) (108) X500 4 (501) (500) X500 4 I9.4 16R6 16R6.1 I9.7 18R1 I12.2
12.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 12/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Outgoing Feeder Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/13.0 L2/13.0 L3/13.0 N PE L1/11.0 L2/11.0 L3/11.0 N/11.9 PE/11.9 109/11.9 109/13.0 108/11.9 108/13.0 12Q1 12K1 I>I>I> (21) (22) A1 A2 Bungalow-1 (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) (L1) (L2) (L3) (109) A1 A2 (11) (14) Q8.1 (109) (131) I12.3 I12.4 (E) R Y B N E (N) (109) (109) 100/4...20mA 12CT1 + PIW194To PLC AI Channel At page 25.2 100/4...20mA + To PLC AI Channel At page 25.3 To PLC AI Channel At page 25.4 (109) (109) 12CT1.1 PIW196 100/4...20mA 12CT1.2 + PIW198 OF SD FEEDER CIRCUIT 59KW NSX100F TM-D Molded Case Circuit Breaker with Adjustable Rating 70-100A Triple Pole 36kA LC1D115 Magnetic Contactor 115A_59KW with built in Auxiliary Contact (2N/O + 2N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB Outgoing Feeder Circuit 59KW for Bungalow-1 (108) (108) X500 6 (501) (500) X500 6 18R1.1 I12.5
13.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 13/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing Outgoing Feeder Circuits D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 L1/14.0 L2/14.0 L3/14.0 N PE L1/12.0 L2/12.0 L3/12.0 N/12.9 PE/12.9 109/12.9 109/14.0 108/12.9 108/14.0 13Q1 13K1 I>I>I> (21) (22) A1 A2 Servant Quarter-2 (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) (L1) (L2) (L3) (109) A1 A2 (11) (14) Q8.2 (109) (132) I12.6 I12.7 (E) (N) (109) (109) 100/4...20mA 13CT1 + PIW200To PLC AI Channel At page 25.5 100/4...20mA + To PLC AI Channel At page 25.6 To PLC AI Channel At page 25.7 (109) (109) 13CT1.1 PIW202 100/4...20mA 13CT1.2 + PIW204 OF SD FEEDER CIRCUIT 45KW NSX100F TM-D Molded Case Circuit Breaker with Adjustable Rating 56-80A Triple Pole 36kA LC1D80 Magnetic Contactor 80A_45KW with built in Auxiliary Contact (1N/O + 1N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB Outgoing Feeder Circuit 45KW for Servant Quarter-2 300X300 301 302 N E 13Q4 13K4 I>I>I> (21) (22) A1 A2 Welding Socket, DB (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) (L1) (L2) (L3) (109) A1 A2 (11) (14) Q8.3 (109) (133) I13.1 I13.2 (E) (N) (109) (109) 100/4...20mA 13CT4 + PIW206To PLC AI Channel At page 25.8 100/4...20mA + To PLC AI Channel At page 26.1 To PLC AI Channel At page 26.2 (109) (109) 13CT4.1 PIW208 100/4...20mA 13CT4.2 + PIW210 OF SD FEEDER CIRCUIT 37KW NSX100F TM-D Molded Case Circuit Breaker with Adjustable Rating 44-63A Triple Pole 36kA LC1D65 Magnetic Contactor 65A_37KW with built in Auxiliary Contact (1N/O + 1N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB Outgoing Feeder Circuit 37KW for Welding Socket, Local DB 303X300 304 305 N E 13Q8 13K8 I>I>I> (21) (22) A1 A2 Servant Quarter-1 (13) (14) (13) (14) (1/L1) (3/L2) (5/L3) (2/T1) (4/T2) (6/T3) (L1) (L2) (L3) (109) A1 A2 (11) (14) Q8.4 (109) (134) I13.4 I13.5 (E) (N) (109) (109) 40/4...20mA 13CT8 + PIW212To PLC AI Channel At page 26.3 40/4...20mA + To PLC AI Channel At page 26.4 To PLC AI Channel At page 26.5 (109) (109) 13CT8.1 PIW214 40/4...20mA 13CT8.2 + PIW216 OF SD FEEDER CIRCUIT 11KW NSX100F TM-D Molded Case Circuit Breaker with Adjustable Rating 18-25A Triple Pole 36kA LC1D25 Magnetic Contactor 25A_11KW with built in Auxiliary Contact (1N/O + 1N/C) Coil Voltage 220VAC ACCESSORIES OF & SD Auxiliary Switch "OF" & "SD" for MCCB Outgoing Feeder Circuit 11KW for Servant Quarter-1 306X300 307 308 N E (108) (108) X500 7 (501) (500) X500 7 I13.0 18R2 (108) (108) X500 7 (501) (500) X500 7 I13.3 18R2.1 (108) (108) X500 7 (501) (500) X500 7 I13.6 18R3
14.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 14/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing PLC I/O’s Address Detail and Layout D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 109/13.9 109/15.0 CSM 1277 SIMATIC NET 6GK7277- 1AA10-0AA0 P1 P2 P3 P4 CM 1241 RS422/485 6ES7241- 1CH31-0XB0 Tx Rx S7-1200 PLC RACK MODULE ARRANGEMENT 9 8 7 6 5 4 3 2 1 14A1 HMI TOUCH DISPLAY 6AV6647-0AD11-3AX0 SIMATIC HMI KTP600 BASIC COLOR PN CPU 1214C DC/DC/Rly 6ES7214-1HG31-0XB0 RUN ERRO R MAINT SB 1221 DI 4 x 24 VDC 6ES7221-3BD30-0XB0 SIMATIC S7-1200 L+ M GND 24VDC L+ M GND 24VDC IN L+ M 24VDC OUT 1M I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 I1.0 I1.1 I1.2 I1.3 IW64 IW672MI1.4 I1.5 0-10V 1L Q0.0 Q0.1 Q0.2 Q0.3 Q0.4 2L Q0.5 Q0.6 Q0.7 Q1.0 Q1.1 L+ 24VDC IN M I4.0 I4.1 I4.2 I4.3 -VE SOURCING INPUTS +VE SINKING INPUTS SM 1223 DC/Rly 6ES7223-1PL32-0XB0 L+ M GND 24VDC IN 1M I8.0 I8.1 I8.2 I8.3 I8.4 I8.5 I8.6 I8.7 2M I9.0 I9.1 I9.2 I9.3 I9.4 I9.5 I9.6 I9.7+VE SINKING INPUTS 3L Q9.0 Q9.1 Q9.2 Q9.3 4L Q9.4 Q9.5 Q9.6 1L Q8.0 Q8.1 Q8.2 Q8.3 2L Q8.4 Q8.5 Q8.6 Q8.7 Q9.7 SM 1223 DC/Rly 6ES7223-1PL32-0XB0 L+ M GND 24VDC IN 1M I12.0 I12.1 I12.2 I12.3 I12.4 I12.5 I12.6 I12.7 2M I13.0 I13.1 I13.2 I13.3 I13.4 I13.5 I13.6 I13.7+VE SINKING INPUTS 3L Q13.0 Q13.1Q13.2 Q13.3 4L Q13.4 Q13.5Q13.6 1L Q12.0 Q12.1Q12.2 Q12.3 2L Q12.4Q12.5 Q12.6 Q12.7 Q13.7 SM 1231 AI 6ES7231-4HF32-0XB0 L+ M GND 24VDC IN IW128 0+ 0- IW130 1+ 1- IW132 2+ 2- IW134 3+ 3- IW138 5+ 5- IW136 4+ 4- IW140 6+ 6- IW142 7+ 7- SM 1231 AI 6ES7231-4HF32-0XB0 L+ M GND 24VDC IN IW144 0+ 0- IW146 1+ 1- IW148 2+ 2- IW150 3+ 3- IW154 5+ 5- IW152 4+ 4- IW156 6+ 6- IW158 7+ 7- SM 1231 AI 6ES7231-4HF32-0XB0 L+ M GND 24VDC IN IW160 0+ 0- IW162 1+ 1- IW164 2+ 2- IW166 3+ 3- IW170 5+ 5- IW168 4+ 4- IW172 6+ 6- IW174 7+ 7- SM 1231 AI 6ES7231-4HF32-0XB0 L+ M GND 24VDC IN IW176 0+ 0- IW178 1+ 1- IW180 2+ 2- IW182 3+ 3- IW186 5+ 5- IW184 4+ 4- IW188 6+ 6- IW190 7+ 7- SM 1231 AI 6ES7231-4HF32-0XB0 L+ M GND 24VDC IN IW192 0+ 0- IW194 1+ 1- IW196 2+ 2- IW198 3+ 3- IW202 5+ 5- IW200 4+ 4- IW204 6+ 6- IW206 7+ 7- SM 1231 AI 6ES7231-4HF32-0XB0 L+ M GND 24VDC IN IW208 0+ 0- IW210 1+ 1- IW212 2+ 2- IW214 3+ 3- IW218 5+ 5- IW216 4+ 4- IW220 6+ 6- IW222 7+ 7- 14N0 14N1 14N2 14N3 14N4 14N5 14N6 14N7 14N8 14N9 14N9.1 14F0 (4A) 108/13.9 108/15.0 PEPE/13.9 24vdc (150) (151) (150A) (150) (151) (151) (150A) (151) (150) (151) (150) (151) (150) (151) (150) (151) (150) (151) (150) (151) (150) (151) (150) (151) (150) (151)(151) 14S0 13 14 444/15.0 (444) 14N2.1 21 22 14S0 (150A) (150A) (150A) (150) Pin 3 RxD/TxD- Signal A Pin 8 RxD/TxD+ Signal B Pin 5 GND RS-485 5U7 from page 6.9 A1 A2 14R1 A1 A2 14R1.1 A1 A2 14R1.2 A1 A2 14R1.3 1 2 3 4 X666 1 2 3 4 5 X666 (150) (151) 3 3 2 2 1 1 4 4 5 5 6 6 7 7 8 8 9 9 10 10 5 6 7 8 9 10 6 7 8 9 10 X666
15.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 15/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing CPU 1214C and SB 1221 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/14.9 444/14.9 444/16.0 108/14.9 108/16.0 .1 .2 .3 .4 .5 .6 .7 .0 I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 I1.0 8Q1 MCCB ON 8Q1 MCCB TRIP 8K1 CONTACTOR ON FEED BACK .1 I1.1 .0 .2 .3 .4 .5 I1.2 I1.3 I1.4 I1.5 8Q4 MCCB ON 8Q4 MCCB TRIP 8K4 CONTACTOR ON FEED BACK 8Q8 MCCB ON 8Q8 MCCB TRIP 8K8 CONTACTOR ON FEED BACK 9Q1 MCCB ON 9Q1 MCCB TRIP 9K1 CONTACTOR ON FEED BACK 9Q4 MCCB ON 9Q4 MCCB TRIP .0 .1 .2 .3 I4.0 I4.1 I4.2 I4.3 6U1 CHARGER FAILURE 6U7 CHARGER FAILURE SPARE SPARE 109/14.9 109/16.0 (109) 8K1SD8Q1OF8Q1 (I0.1) 21 22 13 14 (I0.0) 13 14 (I0.2) (109) 8K4SD8Q4OF8Q4 (I0.4) 21 22 13 14 (I0.3) 13 14 (I0.5) (109) 8K8SD8Q8OF8Q8 (I0.7) 21 22 13 14 (I0.6) 13 14 (I1.0) (109) 9K1SD9Q1OF9Q1 (I1.2) 21 22 13 14 (I1.1) 13 14 (I1.3) 14N2 14N2.1 (109) SD9Q4OF9Q4 (I1.5) 21 22 13 14 (I1.4) 13 14 13 14 6U1 6U7 (I4.0) (I4.1) (I4.2) (108) X400 1 (I4.2) 2
16.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 16/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing CPU 1214C Outputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/15.9 109/15.9 109/17.0 108/15.9 108/17.0 .1 .2 .3 .4 .5 .6 8.7 .0 Q1.1Q1.0Q0.7Q0.6Q0.5Q0.4Q0.3Q0.2Q0.1 11K4 CONTACTOR ON OUTPUT 11K1 CONTACTOR ON OUTPUT 10K4 CONTACTOR ON OUTPUT 10K1 CONTACTOR ON OUTPUT 9K8 CONTACTOR ON OUTPUT 9K1 CONTACTOR ON OUTPUT 8K4 CONTACTOR ON OUTPUT 8K8 CONTACTOR ON OUTPUT 8K1 CONTACTOR ON OUTPUT .1 Q0.0 .0 9K4 CONTACTOR ON OUTPUT A1 A2 16R2 (Q0.0) A1 A2 16R2.1 (Q0.1) A1 A2 16R3 (Q0.2) A1 A2 16R3.1 (Q0.3) A1 A2 16R4 (Q0.4) A1 A2 16R4.1 (Q0.5) A1 A2 16R5 (Q0.6) A1 A2 16R5.1 (Q0.7) A1 A2 16R6 (Q1.0) A1 A2 16R6.1 (Q1.1) (108) (108) (108) (108) (108) (108) (108) (108) (108) (108) 444/15.9 444/17.0 14N2 (444) X444 X444 3 4 5 6 721 X444 10 11 12 13 1498 X444 15 16 17 18 19 9 5 14R1 10 6 14R1 11 7 14R1 12 8 14R1 9 5 14R1.1 10 6 14R1.1 11 7 14R1.1 12 8 14R1.1 9 5 14R1.2 10 6 14R1.2 1 2 3 4 5 6 7 8 9 10
17.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 17/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1223 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/16.9 444/16.9 444/18.0 108/16.9 108/18.0 .1 .2 .3 .4 .5 .6 .7 .0 I8.0 I8.1 I8.2 I8.3 I8.4 I8.5 I8.6 I8.7 I9.0 9K4 CONTACTOR ON FEED BACK 9Q8 MCCB ON 9Q8 MCCB TRIP .1 I9.1 .0 .2 .3 .4 .5 I9.2 I9.3 I9.4 I9.5 9K8 CONTACTOR ON FEED BACK 10Q1 MCCB ON 10Q1 MCCB TRIP 10K1 CONTACTOR ON FEED BACK 10Q4 MCCB ON 10Q4 MCCB TRIP 10K4 CONTACTOR ON FEED BACK 11Q1 MCCB ON 11Q1 MCCB TRIP 11K1 CONTACTOR ON FEED BACK 11Q4 MCCB ON .6 .7 I9.6 I9.7 11Q4 MCCB TRIP 11K4 CONTACTOR ON FEED BACK 109/16.9 109/18.0 (109) 9K4 13 14 (I8.0) 14N3 (109) 9K8SD9Q8OF9Q8 (I8.2) 21 22 13 14 (I8.1) 13 14 (I8.3) (109) 10K1SD10Q1OF10Q1 (I8.5) 21 22 13 14 (I8.4) 13 14 (I8.6) (109) 10K4SD10Q4OF10Q4 (I9.0) 21 22 13 14 (I8.7) 13 14 (I9.1) (109) 11K1SD11Q1OF11Q1 (I9.3) 21 22 13 14 (I9.2) 13 14 (I9.4) (109) 11K4SD11Q4OF11Q4 (I9.6) 21 22 13 14 (I9.5) 13 14 (I9.7)
18.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 18/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1223 Outputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/13.9 108/13.9 108/15.0 109/15.9 109/17.0 444/15.9 444/17.0 .1 .2 .3 .4 .5 .6 8.7 Q8.7Q8.6Q8.5Q8.4Q8.3Q8.2Q8.1 SPARESPARESPARE 13K4 CONTACTOR ON OUTPUT 12K1 CONTACTOR ON OUTPUT 13K1 CONTACTOR ON OUTPUT 11K8 CONTACTOR ON OUTPUT Q8.0 .0 13K8 CONTACTOR ON OUTPUT A1 A2 18R1 (Q8.0) A1 A2 18R1.1 (Q8.1) A1 A2 18R2 (Q8.2) A1 A2 18R2.1 (Q8.3) A1 A2 18R3 (Q8.4) A1 A2 18R3.1 (Q8.5) A1 A2 18R4 (Q8.6) A1 A2 18R4.1 (Q8.7) (108) (108) (108) (108) (108) (108) (108) (108) .1 .2 .3 .4 .5 .6 8.7 Q9.7Q9.6Q9.5Q9.4Q9.3Q9.2Q9.1 SPARESPARESPARESPARESPARE SPARESPARE Q9.0 .0 SPARE A1 A2 18R5 (Q9.0) A1 A2 18R5.1 (Q9.1) A1 A2 18R6 (Q9.2) A1 A2 18R6.1 (Q9.3) A1 A2 18R7 (Q9.4) A1 A2 18R7.1 (Q9.5) A1 A2 18R8 (Q9.6) A1 A2 18R8.1 (Q9.7) (108) (108) (108) (108) (108) (108) (108) (108) (444) X444 14N3 11 7 14R1.2 12 8 14R1.2 9 5 14R1.3 10 6 14R1.3 11 12 13 14 11 7 14R1.3 15 12 8 14R1.3 16
19.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 19/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1223 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/18.9 444/18.9 444/20.0 108/18.9 108/20.0 .1 .2 .3 .4 .5 .6 .7 .0 I12.0 I12.1 I12.2 I12.3 I12.4 I12.5 I12.6 I12.7 I13.0 11Q8 MCCB ON 11Q8 MCCB TRIP .1 I13.1 .0 .2 .3 .4 .5 I13.2 I13.3 I13.4 I13.5 11K8 CONTACTOR ON FEED BACK 12Q1 MCCB ON 12Q1 MCCB TRIP 12K1 CONTACTOR ON FEED BACK 13Q1 MCCB ON 13Q1 MCCB TRIP 13K1 CONTACTOR ON FEED BACK 13Q4 MCCB ON 13Q4 MCCB TRIP 13K4 CONTACTOR ON FEED BACK 13Q8 MCCB ON .6 .7 I13.6 I13.7 13Q8 MCCB TRIP 13K8 CONTACTOR ON FEED BACK 109/18.9 109/20.0 14N4 (109) 13K8SD13Q8OF13Q8 21 22 13 14 13 14 (109) 11K8SD11Q8OF11Q8 (I12.1) 21 22 13 14 (I12.0) 13 14 (109) 12K1SD12Q1OF12Q1 21 22 13 14 13 14 (109) 13K1SD13Q1OF13Q1 21 22 13 14 13 14 (109) 13K4SD13Q4OF13Q4 21 22 13 14 13 14 (I12.2) (I12.3) (I12.4) (I12.5) (I12.6) (I12.7) (I13.0) (I13.1) (I13.2) (I13.3) (I13.4) (I13.5) (I13.6) (I13.7) GENERATOR ACB CLOSE From page 5.4
20.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 20/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1223 Outputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/19.9 108/19.9 108/21.0 109/19.9 109/21.0 444/19.9 .1 .2 .3 .4 .5 .6 8.7 Q12.7Q12.6Q12.5Q12.4Q12.3Q12.2Q12.1 SPARESPARESPARESPARESPARE SPARESPARE Q12.0 .0 SPARE A1 A2 20R1 (Q12.0) A1 A2 20R1.1 (Q12.1) (108) (108) .1 .2 .3 .4 .5 .6 8.7 Q13.7Q13.6Q13.5Q13.4Q13.3Q13.2Q13.1 SPARESPARESPARESPARESPARE SPARESPARE Q13.0 .0 SPARE 14N4 X400 4 (Q12.2) 5 (Q12.3) 6 (Q12.4) 7 (Q12.5) 8 (Q12.6) 9 (Q12.7) 10 (Q13.0) 11 (Q13.1) 12 (Q13.2) 13 (Q13.3) 14 (Q13.4) 15 (Q13.5) 16 (Q13.6) 17 (Q13.7)
21.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 21/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1231 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/20.9 109/20.9 109/22.0 108/20.9 108/22.0 0+ 0- PIW128 PIW128 CH0 8CT1 0….400A/4….20mA 600 601 X600 14N5 - + 8CT1 0-400/4-20mA 603 1+ 1- PIW130 PIW130 CH1 8CT1.1 0….400A/4….20mA 602 - + 8CT1.1 0-400/4-20mA 605 2+ 2- PIW132 PIW132 CH2 8CT1.2 0….400A/4….20mA 604 - + 8CT1.2 0-400/4-20mA (PIW128) (109) (108) (109) (108) (109) (108) (108) (PIW130) (108) (PIW132) (108) 607 3+ 3- PIW134 PIW134 CH3 8CT4 0….400A/4….20mA 606 - + 8CT4 0-400/4-20mA (109) (108) (PIW134) (108) 609 4+ 4- PIW136 PIW136 CH4 8CT4.1 0….400A/4….20mA 608 - + 8CT4.1 0-400/4-20mA 611 5+ 5- PIW138 PIW138 CH5 8CT4.2 0….400A/4….20mA 610 - + 8CT4.2 0-400/4-20mA 613 6+ 6- PIW140 PIW140 CH6 8CT8 0….400A/4….20mA 612 - + 8CT8 0-400/4-20mA 615 7+ 7- PIW142 PIW142 CH7 8CT8.1 0….400A/4….20mA 614 - + 8CT8.1 0-400/4-20mA (PIW136) (108) (PIW138) (108) (PIW140) (108) (PIW142) (108) (109) (108) (109) (108) (109) (108) (109) (108)
22.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 22/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1231 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/21.9 109/21.9 109/23.0 108/21.9 108/23.0 0+ 0- PIW144 PIW144 CH0 8CT8.2 0….400A/4….20mA 616 617 X600 14N6 - + 8CT8.2 0-400/4-20mA 619 1+ 1- PIW146 PIW146 CH1 9CT1 0….400A/4….20mA 618 - + 9CT1 0-400/4-20mA 621 2+ 2- PIW148 PIW148 CH2 9CT1.1 0….400A/4….20mA 620 - + 9CT1.1 0-400/4-20mA (PIW144) (109) (108) (109) (108) (109) (108) (108) (PIW146) (108) (PIW148) (108) 623 3+ 3- PIW150 PIW150 CH3 9CT1.2 0….400A/4….20mA 622 - + 9CT1.2 0-400/4-20mA (109) (108) (PIW150) (108) 625 4+ 4- PIW152 PIW152 CH4 9CT4 0….250A/4….20mA 624 - + 9CT4 0-250/4-20mA 627 5+ 5- PIW154 PIW154 CH5 9CT4.1 0….250A/4….20mA 626 - + 9CT4.1 0-250/4-20mA 629 6+ 6- PIW156 PIW156 CH6 9CT4.2 0….250A/4….20mA 628 - + 9CT4.2 0-250/4-20mA 631 7+ 7- PIW158 PIW158 CH7 9CT8 0….250A/4….20mA 630 - + 9CT8 0-250/4-20mA (PIW152) (108) (PIW154) (108) (PIW156) (108) (PIW158) (108) (109) (108) (109) (108) (109) (108) (109) (108)
23.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 23/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1231 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/21.9 109/21.9 109/23.0 108/21.9 108/23.0 0+ 0- PIW160 PIW160 CH0 9CT8.1 0….250A/4….20mA 632 633 X600 14N7 - + 9CT8.1 0-250/4-20mA 635 1+ 1- PIW162 PIW162 CH1 9CT8.2 0….250A/4….20mA 634 - + 9CT8.2 0-250/4-20mA 637 2+ 2- PIW164 PIW164 CH2 10CT1 0….250A/4….20mA 636 - + 10CT1 0-250/4-20mA (PIW160) (109) (108) (109) (108) (109) (108) (108) (PIW162) (108) (PIW164) (108) 639 3+ 3- PIW166 PIW166 CH3 10CT1.1 0….250A/4….20mA 638 - + 10CT1.1 0-250/4-20mA (109) (108) (PIW166) (108) 641 4+ 4- PIW168 PIW168 CH4 10CT1.2 0….250A/4….20mA 640 - + 10CT1.2 0-250/4-20mA 643 5+ 5- PIW170 PIW170 CH5 10CT4 0….250A/4….20mA 642 - + 10CT4 0-250/4-20mA 645 6+ 6- PIW172 PIW172 CH6 10CT4.1 0….250A/4….20mA 644 - + 10CT4.1 0-250/4-20mA 647 7+ 7- PIW174 PIW174 CH7 10CT4.2 0….250A/4….20mA 646 - + 10CT4.2 0-250/4-20mA (PIW168) (108) (PIW170) (108) (PIW172) (108) (PIW174) (108) (109) (108) (109) (108) (109) (108) (109) (108)
24.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 24/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1231 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/23.9 109/23.9 109/25.0 108/23.9 108/25.0 0+ 0- PIW176 PIW176 CH0 11CT1 0….100A/4….20mA 648 649 X600 14N8 - + 11CT1 0-100/4-20mA 651 1+ 1- PIW178 PIW178 CH1 11CT1.1 0….100A/4….20mA 650 - + 11CT1.1 0-100/4-20mA 653 2+ 2- PIW180 PIW180 CH2 11CT1.2 0….100A/4….20mA 652 - + 11CT1.2 0-100/4-20mA (PIW176) (109) (108) (109) (108) (109) (108) (108) (PIW178) (108) (PIW180) (108) 655 3+ 3- PIW182 PIW182 CH3 11CT4 0….100A/4….20mA 654 - + 11CT4 0-100/4-20mA (109) (108) (PIW182) (108) 657 4+ 4- PIW184 PIW184 CH4 11CT4.1 0….100A/4….20mA 656 - + 11CT4.1 0-100/4-20mA 659 5+ 5- PIW186 PIW186 CH5 11CT4.2 0….100A/4….20mA 658 - + 11CT4.2 0-100/4-20mA 661 6+ 6- PIW188 PIW188 CH6 11CT8 0….100A/4….20mA 660 - + 11CT8 0-100/4-20mA 663 7+ 7- PIW190 PIW190 CH7 11CT8.1 0….100A/4….20mA 662 - + 11CT8.1 0-100/4-20mA (PIW184) (108) (PIW186) (108) (PIW188) (108) (PIW190) (108) (109) (108) (109) (108) (109) (108) (109) (108)
25.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 25/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1231 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PEPE/24.9 109/24.9 109/26.0 108/24.9 108/26.0 0+ 0- PIW192 PIW192 CH0 11CT8.2 0….100A/4….20mA 664 665 X600 14N9 - + 11CT8.2 0-100/4-20mA 667 1+ 1- PIW194 PIW194 CH1 12CT1 0….100A/4….20mA 666 - + 12CT1 0-100/4-20mA 669 2+ 2- PIW196 PIW196 CH2 12CT1.1 0….100A/4….20mA 668 - + 12CT1.1 0-100/4-20mA (PIW192) (109) (108) (109) (108) (109) (108) (108) (PIW194) (108) (PIW196) (108) 671 3+ 3- PIW198 PIW198 CH3 12CT1.2 0….100A/4….20mA 670 - + 12CT1.2 0-100/4-20mA (109) (108) (PIW198) (108) 673 4+ 4- PIW200 PIW200 CH4 13CT1 0….100A/4….20mA 672 - + 13CT1 0-100/4-20mA 675 5+ 5- PIW202 PIW202 CH5 13CT1.1 0….100A/4….20mA 674 - + 13CT1.1 0-100/4-20mA 677 6+ 6- PIW204 PIW204 CH6 13CT1.2 0….100A/4….20mA 676 - + 13CT1.2 0-100/4-20mA 679 7+ 7- PIW206 PIW206 CH7 13CT4 0….100A/4….20mA 678 - + 13CT4 0-100/4-20mA (PIW200) (108) (PIW202) (108) (PIW204) (108) (PIW206) (108) (109) (108) (109) (108) (109) (108) (109) (108)
26.
0 Company Name:Client Name: WATT
N VOLT Industrial Automation & Engineering 18th-km. Ferozepur Road, Lahore Pakistan. Tel: +92 42 35401829 ,35401830 Fax: +92 42 35820830 E-mail: wnv@wattnvolt.com.pk Visit us: http://www.wattnvolt.com.pk Unilever Pakistan Limited HPC Factory, Leghari Road, Rahim Yar Khan PABX +92 68 5874906 – 12 Fax +92 68 58775162 - 68 Dated by: Folio: Revised: 19-03-2015 26/26 0 Drawing by: Checked by: DWG #: SARFRAZ Tahir Rasool WNV_UNI_003 Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing SM 1231 Inputs Wiring Diagram D:DocumentsUnilever RYKELMSEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing.vsdFile & Directory Name: Circuit Description: Title: 1 2 3 4 5 6 7 8 9 PE/25.9 109/25.9 108/25.9 0+ 0- PIW208 PIW208 CH0 13CT4.1 0….100A/4….20mA 680 681 X600 14N9.1 - + 13CT4.1 0-100/4-20mA 683 1+ 1- PIW210 PIW210 CH1 13CT4.2 0….100A/4….20mA 682 - + 13CT4.2 0-100/4-20mA 685 2+ 2- PIW212 PIW212 CH2 13CT8 0….40A/4….20mA 684 - + 13CT8 0-40/4-20mA (PIW208) (109) (108) (109) (108) (109) (108) (108) (PIW210) (108) (PIW212) (108) 687 3+ 3- PIW214 PIW214 CH3 13CT8.1 0….40A/4….20mA 686 - + 13CT8.1 0-40/4-20mA (109) (108) (PIW214) (108) 689 4+ 4- PIW216 PIW216 CH4 13CT8.2 0….40A/4….20mA 688 - + 13CT8.2 0-40/4-20mA 691 5+ 5- PIW218 PIW218 CH5 SPARE 690 693 6+ 6- PIW220 PIW220 CH6 SPARE 692 695 7+ 7- PIW222 PIW222 CH7 SPARE 694 (PIW216) (108) (109) (108)
Baixar agora