4. 18,6 TWh tenka šildymui
ir 4,8 TWh karštam
vandeniui ruošti
Šaltinis: Energijos efektyvumo veiksmų planas
UKM 2008 m. gruodžio 4 d. įsakymu Nr. 4-620
24. Šildymas
Šilumos atidavimo būdas- Vandeninis grindinis šildymas
Šilumos šaltinis - Šiluminis siurblys “Stiebel Eltron
WPF 16”
su vertikaliais grunto kolektoriais
25. Rezultatas
Specific Demands with Reference to the Treated Floor Area
Treated Floor Area: 598,6 m2
Applied: Annual method PH Certificate: Fulfilled?
kWh/(m2
Specific Space Heating Demand: 14 a)
15kWh/(m²a)
Yes
Heating Load: 9 W/m² 10W/m²
Pressurization Test Result: 0,5 h-1 0,6h-1 Yes
Specific Primary Energy Demand
(DHW, Heating, Cooling, Auxiliary and Household Electricity): 85 kWh/(m2a) 120kWh/(m²a) Yes
Specific Primary Energy Demand
(DHW, Heating and Auxiliary Electricity): 43 kWh/(m2a)
Specific Primary Energy Reduction
through Solar Electricity: kWh/(m2a)
Frequency of Overheating: 0 % over 25 °C
Specific Useful Cooling Energy Demand: kWh/(m2a) 15kWh/(m²a)
2
Cooling Load: 3 W/m
www.passivhausprojekte.de ID:2399