3. Next Generation DiagnostX
US Patents: 8565096, 8948022, 9282482, 8600371,
8825042, 9432866. Other patents pending.
TM
4. DiagnostX is an over-the-air radio analyzer –
the only one on the market.
DiagnostX monitors the base station
RECEIVE frequency, analyzing all control
channel transmissions from the subscriber
radios on the system.
4
5. Operation
• Connect to an AC power
source (100-240V, 50-60 Hz)
• Connect to an antenna:
RX antenna at the multi-coupler or
stand-alone antenna
• Enter Control Channel
frequencies
• Define Thresholds
5
Registration
Group Affiliation
PTT
DiagnostX Viewer Console
6. Stand-alone or System-wide Coverage
• DiagnostX DX-2002 can be used as a stand-alone
unit, or it can be extended with up to three NX-200
remote receivers
• Data from the NX-200 units are sent to the DX-2002
via IP connectivity
6
8. DiagnostX is Protocol and Frequency
Band Specific
Available Protocols:
• P25 Trunked
• P25 Conventional
• SmartNet™/SmartZone™
• MOTOTRBO
• EDACS
• NXDN
Available Frequencies:
• VHF (136-174)
• UHF (380-430 or 450-470 or 470-512)
• 700 MHz
• 800 MHz
• 900 MHz
8
9. P25 Metrics and Measurements
1. Frequency Error
2. Symbol Error 600, Symbol Error 1800
3. Maximum Frequency Deviation
4. Modulation Fidelity
5. BER (on a per transmission basis, %)
6. RSSI (on a per transmission basis, dBm)
7. SNR (on a per transmission basis)
8. Reserve Gain at the multi-coupler (dBm)
9
14. Benefits of DiagnostX
1. Ensures operational readiness - measures radio alignment
constantly
2. Reduces maintenance costs by addressing only radios out of
specification
3. The ideal complement to an auto-tune service monitor
4. Indispensible P25 migration tool
5. Completely autonomous from the radio system
14