This document summarizes NetCeler, a French company that has provided automated disturbance analysis software called IVPower to utilities for 20 years. IVPower is a modular system that can be customized with different modules. It has been implemented by various transmission and distribution system operators around the world. IVPower provides automated fault location, asset monitoring, power quality monitoring, and wide area monitoring capabilities. It integrates data from existing utility systems. IVPower supports real-time network supervision to quickly identify faults and post-mortem analysis to improve system efficiency. It automatically analyzes events, locates faults accurately, monitors protection performance, and makes recommendations to utilities.
2. Presentation of NetCeler
2
French company, since 1997
Based in France (Two main offices)
50-people staff
20 years of experience
Creator of Innovative Monitoring Solutions
IVPower : Real-time Monitoring Solution Software for Power Utilities
3. IVPower : A Modular System
3
Any combinations of modules for the best application requirement fit
6. Localisation of our References
6
Our Global Reach: Wherever our Clients are located
• France
• Italy
• Switzerland
• Germany
• Portugal
• Romania
• Turkey
• Saudi Arabia
• Canada
• Singapore
• China
• South Africa
• Mexico
• Chile
• Belgium
• Netherlands
• Spain
• Denmark
7. ROI : Customer Voice
7
RTE example
Brochure prepared
by RTE for CIGRE
2016
8.
9. IVPower : Decision Support Tool for Utilities
9
Support network control
Accurate and reliable fault
location
Automated Conclusions
presented to the Operator (with
suggestions)
AFA+
PQ WAM
Flicker&Harmonics Grid Instability
Streamline the event analysis
Event sequence timeline
automated
Characterization on the
Disturbance
Perform verifications
systematically
Support conditional maintenance
Monitor breakers and relay performance
Pinpoint abnormal events : e.g late tripping
Record correct operation to postpone
maintenance, if unnecessary
DST = Real-time & Automated Fault Location,
Asset Operational Monitoring, PQ, WAM
10. Legacy from Existing Environment
10
Meters DPR/DFR PMU SAS
Dispatching
(fault location)
Asset
management
Maintenance
Power
Quality
Substation
Information
Data
An Integrated Decision Support Tool, IVPower
takes into account existing systems and leverages their data
12. Power Grid Monitoring
12
1. Real Time Supervision
• Goal: quickly & reliably identify faulty scenario
Deploy Emergency crew in a targeted small area
Reduce outage time
2. Post-mortem Analysis
• Goal: improve efficiency and system quality
Fault analysis & characterization – type, duration, fault impedance, distance
Voltage Quality and Stability – power quality
Asset mulfunctioning with root cause analysis
Data archival for statistical analysis
Frequency Stability - Wide Area Monitoring
1 Platform : 2 Types of Monitoring, 2 Systems…
13. Automated Fault Analysis
13
Use of oscillographic records (COMTRADE format)
Time saving: automatic collection and classification
of various event-related following any disturbance.
Fast indication (within a few minutes) of healthy /
faulty lines
Fast indication of accurate and reliable fault location
to optimize crew interventions:
Presentation of the sequence of events,
measurements and key performance indicators to
facilitate and speed up the post mortem analysis
Providing of fault statistics regarding lines,
transformers, breakers and protection devices.
Main Benefits
Boasts productivity of both dispatching crews and post-mortem analysts
14. Automated Fault Analysis
14
Fault position in km from substation
Fault accuracy: 5% of line length, (98%
prob.)
Geographical view with the fault position
Graphical representation of the fault
Red rectangle : tolerance zone
Geo-located indication of the fault position
15. Automated Fault Analysis
15
L1-G short circuit on line Klm-WOL 536
The short circuit is located at 4.77 km [Mast356;Mast355] +/- 1.27 km from station Wolmirstedt
Line Klm-Wol 536 is surely faulty
L1-G short circuit on line Eu-Wd 208
The short circuit is located at 62.35 km [Mast181;Mast182] +/- 3.36 km from station Eula
Line EU-WD is surely faulty
Manual reclosing suggestion
According to the analyzed
elements, IVPower suggests
to reclose the line manually
According to the analyzed
elements, IVPower suggests NOT
to reclose the line manually
16. Automated Fault Analysis
16
Presented in a relative time scale
The time origin : start of fault
Located faults and relay trips shown
by default
Additionally, feeder, station binary
signals or additional (secondary) fault
locations may be added to the event
timeline
Sequence of fault event
17. Protection Performance Monitoring
17
Detection of latent defects in the protection system
Every disturbance event will trigger an automated performance analysis of the
concerned IED
Maintenance inspections planned according to IED performances, not time
Main Benefits
18. Protection Performance Monitoring
18
Selection of the device type:
relays, CB’s
Upon every disturbance event is
an automated performance test
for concerned IED’s and CB’s
Statistical data can be linked to
external data historian systems
Custom protection monitoring
rules can be added through a
development environment
Asset Management : Protection statistics
Columns show:
-Latest observed behavior during an event, corresponding to a binary signal transition from the device
-Device ID
-Bay on which the device is installed-Number of observations
-Percentage of correct behaviors
-Number of correct behaviors