SlideShare uma empresa Scribd logo
1 de 4
Baixar para ler offline
David Roller
2705 2nd Street South
Cranbrook, BC V1C 5B5
Cell Number: 250-426-7671
Email: wec1@telus.net
Career Objective:​ To be a part of a production and electrical team that will utilize my technical
training, education, experience and will provide ongoing professional development.
Safety minded team player that uses logical and long range vision to face the
challenges of today and has a proven track record of meeting those challenges.
Experienced electrical foreman
Seasoned electrician
Excellent troubleshooting capabilities
Mechanically inclined
Clean safety record
Certified Thermographer
Work History
● Cenovus (sub Dynamysk) 2013- Dec. 2015
CSU/Maintenance Commissioned - function tested 120/208/600 4160 volt motors to 200 HP
also associated drives, DCS. Control, Thermon HT Controllers, HVAC and heating systems,
UPS systems,Emergency Generator Units, HV and LV Transformers all HV switch gear,
including Multilins,600 Volt MCCs, also various other LV. devices and equipment, closed out
work orders, entered defects on Maximo, researched pulled up drawings, also able to work off
commissioning packages effectively.
● MMR Canada 2012-2013
CSU/project support- worked at the Hydro Transportations and Tailings Area.
Filled out and signing out job specifics daily (permit to work).
Attended and joined in on daily crew safety meetings. Specific equipment check sheet, single
line diagrams, and prints, statistic check sheets or “B” sheets, DCD (Dynamic Commission
Documents)
Performed appropriate equipment tests: HI potting, Ductor meggering (DLRO), EZ-CT
Ratio/Saturation Testing (EZCT-10), Digital Transformer Ratio Meter (DTR model 85100),
5000V Megger (Fluke 1550C) 5KV Insulation Tester, Multi Meter (Fluke 1587) 1000V insulation,
Rotation Meter (AECMC model 6609), and Impedance Meter. Brady Wire Marker (ID Expert).
Equipment tested: 20 MVA/10 MVA/5MVA- 72 KV/ 4160 Oil Filled Power Transformers, 2
MVA 5KV/600 V Oiled Filled Transformers, 500 KVA Dry Type Transformers, NGRs, assisted
ABB. Rep. to test 72.5 KV Gas Filled (C6) Main Breaker, 5KV (SWG) Buckets, Breakers,
Busses, CTs, PTs, Point to Point Associated Small Pwr. Ups, Control Circuitry, Racked in and
out Breakers, Test Mechanical Lock Out, Shutters, Linkages, 4160 VFDs Circuitry Busses,
Capacitors, Motor Feeds, and Motors. Assisted Baker Hughes with startups of 47HP/85HP,
Back Up Supply Water Down Hole Pumps,600V Distribution (SWG) Buckets, Breaker MCCs,
Motors, VFDs, Rotor Feeds Busses, Breaker
Stabs, CTs, PTs, Mech. Lock Out Shutters, and Rack In/Out Linkages. 600V-120/208V 75, 45,
30KVA Transformers, 120/208 Ltg. Panels and Circuitry, UPDP. Pwr. Panels and Circuitry, and
Ups Pwr/ Hayley Charging Systems. Batteries/ Battery Banks, Contactor Panels and Circuitry.
Studon Electric 2012
● Studon Electric & Controls
Forman on Suncor Well Pad #116 SAGD for Project Startup and
Temp Power for Jackfish #3. Duties included: entering Manpowers daily time on Citrix.
Monitored safety, sign and doubled checked FLRHAs. Checked safety tickets, checked scaffold
tags, and tie off points. Delegate daily job tasks to workers. Tracked and located tools and
material for appointed jobs.
● Independent Electric & Controls Ltd. / Tarpon Energy Services Ltd 2009-2012
Oil and gas field electrical foreman- Worked with a variety of oil field equipment including
compressors, dehydration systems, line heaters, separator packages, pump jacks. Worked with
natural gas/ diesel powered generators, utility systems, oil battery facilities, water injection
pumps and SCADA automation on plant and well sites. Other experience includes programming
of VFD parameters, installation and testing of analog and digital equipment, charging systems,
current, voltage and continuity testing. Maintained records, ordered materials, inventory control
and instructed apprentices.
● Wolverine Electric and Controls Ltd. 2007 – 2009
OWNER/OPERATOR - Worked directly for Petro Canada in well site and facility consulting,
construction and maintenance.
● Westwood Electric Company 2004 - 2005
INDUSTRIAL ELECTRICIAN - Peace Valley OSB Plant start up. Installed underground
raceway cable. Installed and terminated high voltage transformers. Installed and tested high
voltage PDC breakers. Installed stress cones and grounding. At end of construction
commissioned with plant programmer.
Trouble-shot Allen Bradly MCCs/PLCs, Device Net and various field devices.
● Tarpon Energy Limited / Syndicated Technologies Limited 2000 - 2007
Oil and gas field electrical foreman- Worked with a variety of oil field
equipment including compressors, dehydration systems, line heaters, separator packages,
pump jacks.
Worked with natural gas/ diesel powered generators, utility systems, oil battery facilities,
water injection pumps and SCADA automation on plant and well sites. Other experience
includes programming of VFD parameters, installation and testing of analog and digital
equipment, charging systems, current, voltage and continuity testing. Maintained records,
ordered materials, Syndicated Technologies Limited inventory control and instructed
apprentices.
● Houle Electric Company 1992 - 2000
COMMERCIAL/INDUSTRIAL ELECTRICIAN - Maintenance shutdowns, high voltage
transformers and switching. Maintained 13.8kV to 480V transformer banks, lockout load break
switches, and high voltage cables. Blueprint reading and asbuilt upgrading. Merging of cables
and motors. Operated bucket truck. Lockout procedures.
Education
● BCIT Certificate of Qualification: Journeyman Electrician Red Seal
● BCIT Certificate of Apprenticeship: Fourth Year
Courses and Certificates
● Leadership For Safety Excellence
(LSE) Reg.#11193877
● OSSA. Fall Protection (#20110705-26)
● Construction Safety Training System
(CSTS) Reg.#11188356
● Holder Training Program (Global Training)
● St. John Ambulance (OFA. Level #1
First Aid) Ref.# 1-2ABYV3
● OSSA Regional Orientation Program
(AGD-2006-02) C#2012-150
● Programmable Logical Controllers
● Blueprint Reading
● WHMIS
● Aerial Platform Safety Ticket
● Computers for Electricians
● T.G.D.
● Welding for Electricians
● Fire Alarm Systems
● H2S Alive (ID.#2235486)
● ATV Safe Rider
● Electrical Code 2010
● Thermal/ Infrared Thermography Level 1
● Crane Operator Certificate
● Elevated Work Platform (7183)
● CSTS-09 Construction Safety Training System (#11188356)
References available upon request

Daves 2017 updated resume

  • 1. David Roller 2705 2nd Street South Cranbrook, BC V1C 5B5 Cell Number: 250-426-7671 Email: wec1@telus.net Career Objective:​ To be a part of a production and electrical team that will utilize my technical training, education, experience and will provide ongoing professional development. Safety minded team player that uses logical and long range vision to face the challenges of today and has a proven track record of meeting those challenges. Experienced electrical foreman Seasoned electrician Excellent troubleshooting capabilities Mechanically inclined Clean safety record Certified Thermographer Work History ● Cenovus (sub Dynamysk) 2013- Dec. 2015 CSU/Maintenance Commissioned - function tested 120/208/600 4160 volt motors to 200 HP also associated drives, DCS. Control, Thermon HT Controllers, HVAC and heating systems, UPS systems,Emergency Generator Units, HV and LV Transformers all HV switch gear, including Multilins,600 Volt MCCs, also various other LV. devices and equipment, closed out work orders, entered defects on Maximo, researched pulled up drawings, also able to work off commissioning packages effectively. ● MMR Canada 2012-2013 CSU/project support- worked at the Hydro Transportations and Tailings Area. Filled out and signing out job specifics daily (permit to work). Attended and joined in on daily crew safety meetings. Specific equipment check sheet, single line diagrams, and prints, statistic check sheets or “B” sheets, DCD (Dynamic Commission Documents) Performed appropriate equipment tests: HI potting, Ductor meggering (DLRO), EZ-CT Ratio/Saturation Testing (EZCT-10), Digital Transformer Ratio Meter (DTR model 85100), 5000V Megger (Fluke 1550C) 5KV Insulation Tester, Multi Meter (Fluke 1587) 1000V insulation, Rotation Meter (AECMC model 6609), and Impedance Meter. Brady Wire Marker (ID Expert). Equipment tested: 20 MVA/10 MVA/5MVA- 72 KV/ 4160 Oil Filled Power Transformers, 2 MVA 5KV/600 V Oiled Filled Transformers, 500 KVA Dry Type Transformers, NGRs, assisted ABB. Rep. to test 72.5 KV Gas Filled (C6) Main Breaker, 5KV (SWG) Buckets, Breakers,
  • 2. Busses, CTs, PTs, Point to Point Associated Small Pwr. Ups, Control Circuitry, Racked in and out Breakers, Test Mechanical Lock Out, Shutters, Linkages, 4160 VFDs Circuitry Busses, Capacitors, Motor Feeds, and Motors. Assisted Baker Hughes with startups of 47HP/85HP, Back Up Supply Water Down Hole Pumps,600V Distribution (SWG) Buckets, Breaker MCCs, Motors, VFDs, Rotor Feeds Busses, Breaker Stabs, CTs, PTs, Mech. Lock Out Shutters, and Rack In/Out Linkages. 600V-120/208V 75, 45, 30KVA Transformers, 120/208 Ltg. Panels and Circuitry, UPDP. Pwr. Panels and Circuitry, and Ups Pwr/ Hayley Charging Systems. Batteries/ Battery Banks, Contactor Panels and Circuitry. Studon Electric 2012 ● Studon Electric & Controls Forman on Suncor Well Pad #116 SAGD for Project Startup and Temp Power for Jackfish #3. Duties included: entering Manpowers daily time on Citrix. Monitored safety, sign and doubled checked FLRHAs. Checked safety tickets, checked scaffold tags, and tie off points. Delegate daily job tasks to workers. Tracked and located tools and material for appointed jobs. ● Independent Electric & Controls Ltd. / Tarpon Energy Services Ltd 2009-2012 Oil and gas field electrical foreman- Worked with a variety of oil field equipment including compressors, dehydration systems, line heaters, separator packages, pump jacks. Worked with natural gas/ diesel powered generators, utility systems, oil battery facilities, water injection pumps and SCADA automation on plant and well sites. Other experience includes programming of VFD parameters, installation and testing of analog and digital equipment, charging systems, current, voltage and continuity testing. Maintained records, ordered materials, inventory control and instructed apprentices. ● Wolverine Electric and Controls Ltd. 2007 – 2009 OWNER/OPERATOR - Worked directly for Petro Canada in well site and facility consulting, construction and maintenance. ● Westwood Electric Company 2004 - 2005 INDUSTRIAL ELECTRICIAN - Peace Valley OSB Plant start up. Installed underground raceway cable. Installed and terminated high voltage transformers. Installed and tested high voltage PDC breakers. Installed stress cones and grounding. At end of construction commissioned with plant programmer. Trouble-shot Allen Bradly MCCs/PLCs, Device Net and various field devices. ● Tarpon Energy Limited / Syndicated Technologies Limited 2000 - 2007 Oil and gas field electrical foreman- Worked with a variety of oil field equipment including compressors, dehydration systems, line heaters, separator packages, pump jacks. Worked with natural gas/ diesel powered generators, utility systems, oil battery facilities,
  • 3. water injection pumps and SCADA automation on plant and well sites. Other experience includes programming of VFD parameters, installation and testing of analog and digital equipment, charging systems, current, voltage and continuity testing. Maintained records, ordered materials, Syndicated Technologies Limited inventory control and instructed apprentices. ● Houle Electric Company 1992 - 2000 COMMERCIAL/INDUSTRIAL ELECTRICIAN - Maintenance shutdowns, high voltage transformers and switching. Maintained 13.8kV to 480V transformer banks, lockout load break switches, and high voltage cables. Blueprint reading and asbuilt upgrading. Merging of cables and motors. Operated bucket truck. Lockout procedures. Education ● BCIT Certificate of Qualification: Journeyman Electrician Red Seal ● BCIT Certificate of Apprenticeship: Fourth Year Courses and Certificates ● Leadership For Safety Excellence (LSE) Reg.#11193877 ● OSSA. Fall Protection (#20110705-26) ● Construction Safety Training System (CSTS) Reg.#11188356 ● Holder Training Program (Global Training) ● St. John Ambulance (OFA. Level #1 First Aid) Ref.# 1-2ABYV3 ● OSSA Regional Orientation Program (AGD-2006-02) C#2012-150 ● Programmable Logical Controllers ● Blueprint Reading ● WHMIS ● Aerial Platform Safety Ticket ● Computers for Electricians ● T.G.D. ● Welding for Electricians ● Fire Alarm Systems ● H2S Alive (ID.#2235486) ● ATV Safe Rider ● Electrical Code 2010 ● Thermal/ Infrared Thermography Level 1 ● Crane Operator Certificate ● Elevated Work Platform (7183) ● CSTS-09 Construction Safety Training System (#11188356)