2. Product Testing – As per IS1391 Part 1 and IS1391 Part 2 standards
ON/OFF or Fixed Speed (SAC/WAC/CAC/Packaged AC)
DC Inverter AC (SAC/WAC)
Refrigerant (R410A, R32, R290, R22)
Testing SCOPE – As per IS Standard (Psychometric lab/Enthalpy Lab)
Cooling Capacity/ Performance Testing
Power Consumption, EER and ISEER as per BEE 2018 Standards.
Power Factor, Frequency
Max. Operating Condition Test (Low and High Voltage as per IS Conditions)
Freeze up Test
Sweat & Closure Test
Air Flow Measurement
Noise Testing can be done as per IS1391 Part 2 (2018 Amendment 1) in Psychrometric lab
Heating Capacity
Heating Overload condition testing
2
www.coterd.com
3. Psychrometric Laboratory Details:
Lab Type: Psychrometric/ Enthalpy Lab
Rated cooling capacity (T1, T2, T3)
Capacity of Lab: 5 HP
Cooling capacity 9000Btu/hr to 60000 Btu/hr
Heating capacity 9000Btu/hr to 60000 Btu/hr
Air flower rate(Indoor): 250~5000m3/h
Power:
1ф 100~300V/50/60Hz 60A continuous rating (Rating 230V).
3ф 200~500V50/60Hz 30A continuous rating (Rating 415V).
Other test conditions
Indoor ﹢10~50℃ 20~90%RH (dew point ≥8℃)
Outdoor -5~55℃ 20~90%RH (dew point ≥8℃)Size:
Window type: W-under 1000mm; D-under 900mm; H-under 800mm
Split type: W-under 1800mm; D-under 1000mm; H-under 2000mm
Working Capability (24*7) as per customer requirement
3
www.coterd.com
4. NABL Accredited:
All IS and ISO standard covered as per NABL ISO 17025; 2005 & 2017.
4
SCOPE OF NABL (ISO/IEC 17025:2005)
ELECTRICAL TESTING
DOMESTIC ELECTRICAL APPLIANCES
Room Air Condition
(Window, Split and
Inverter Type)
Cooling Capacity
IS 1391 (Part 1) CI. 10. 10
2500 W to 12000 WIS 1391 (Part 2) CI. 9. 9
Power Consumption for
cooling
IS 1391 (Part 1) CI. 10. 8
100 W to 5000 W
IS 1391 (Part 2) CI. 9.7
Maximum operating
Conditions
IS 1391 (Part 1) CI. 10. 4 Qualititative (2500 W
to 12000 W)IS 1391 (Part 2) CI. 9.4
Enclosure Sweat
IS 1391 (Part 1) CI. 10. 6 Qualitative (2500 W to
12000 W)IS 1391 (Part 2) CI. 9.6
Condensate Disposal
IS 1391 (Part 1) CI. 10. 7 Qualitative (2500 W to
12000 W)
Freeze UP
IS 1391 (Part 1) CI. 10. 5 Qualitative (2500 W to
12000 W)IS 1391 (Part 2) CI. 9.5
www.coterd.com
5. Our Project Execution Process:
5
AC
Manufacturer COTERD
Lab
Availability
All AC Testing
Report
Generation
Send to
Customer