SlideShare uma empresa Scribd logo
1 de 53
Baixar para ler offline
Summer Training Report
Delhi Metro Rail Corporation (DMRC)
Submitted by:
ANOOP KUMAR
Workshop Sections of DMRC
CERTIFICATE
This is to certify that the summer Training Report entitled “DELHI
METRO RAIL CORPORATIO LTD.” done by Mr. Anoop kumar, Roll No
1371931011 to the Electronics and Communication Engineering is
an authentic work carried out by him at Axis Institute of Technology and
Management, under my guidance.
Date: Signature of the Guide
Workshop Sections of DMRC
Made in Indian Metro
A $590 million contract for over 400 coaches for phase II has been awarded to BOMBARDIER.
While initial trains will be manufactured in Germany and Sweden, the remainder will be built at
Bombardier's Indian factory in Savli, near Vadodara (Gujrat).
Current Routes
LINE 1 (Dilshad Garden to Rithala via Kashmeri Gate)
LINE 2 (HUDA City Centre (Gurgaon) to Jahangirpuri via Rajiv Chowk & Kashmere Gate)
LINE 3 (Noida City Centre to Dwarka Sector 21 via Rajiv Chowk and Yamuna Bank)
LINE 4 (Yamuna Bank to Anand Vihar ISBT)
LINE 5 (Inderlok to Mundka)
LINE 6 (Central Secretariat to Badarpur)
LINE 7 (Airport METRO Express Line)
TRAIN FORMATION
At present each train-set consists of four cars. Both ends of the train-set are driving trailer car
and middle cars are motor cars. The trailer cars are defined as "DT" car and motor cars are
defined as "M" car.
The train-set can be controlled as a complete unit or as separate units for various maintenance
activities at the depot.
1) 4 car - DT-M-M-DT
2) 6 Car – DT-M-M-T-M-DT
3) 8 Car – DT-M-M-T-M-T-M-DT
SALIENT FEATURE
1. Broad Gauge
2. 25 KV Supply Voltage System
3. Light Weight Stainless Steel Structure
4. Three phase A.C. Induction Motor
5. Fail safe braking system with regenerative Braking
6. VVVF Control
7. Reinforced conical rubber primary suspension
8. Secondary Air Suspension
9. Uniform Floor Height
10. Jerk Controlled Braking
11. Slip/Slide protection
12. Train Integrated Management System
13. PLC based saloon Air-conditioning system
14. Electrically Operated and electronically controlled Saloon Doors
Workshop Sections of DMRCAxis Institute of Technology & Management
15. Emergency Door
16. ATP/ATO
HIGH TENSION SYSTEM
The high tension system consists of the following system/equipments.
1. Pantograph
2. Vacuum Circuit Breaker
3. Surge Arrestor
4. Main Transformer
5. Potential Transformer
The pantograph connects the train electrical system to the overhead current (OHC) supply. The 25000V
AC is supplied to the Main Transformer through VCB. The flow of power becomes as under.
Flow of Power:
OHE Pantograph VCB
Main
Transformer
C/I SIV
Traction Motor
Aircon Main
compressor
110 V
load
220V
Load
Gear case
Power to
Wheels
Oil pump and
blower
Workshop Sections of DMRCAxis Institute of Technology & Management
 PANTOGRAPH
Location:
The Pantograph is located on top of the Vehicle roof structure to allow unhindered access to the
overhead lines.
Function:
The function is to collect the current from the overhead wire by the carbons, which is carried by the
structural members of the unit to the power take off points on the base frame. The insulated bearings,
are by passed by the flexible shunts. The pantograph is attached via 4 foot insulators that support and
insulate the pantograph on the vehicle roof. The Pantograph receives an air supply from the vehicle via
the control panel and air feed insulator allowing the pantograph to be raised and lowered on demand
and maintain contact force with the overhead wire when in the raised operational mode.
Workshop Sections of DMRCAxis Institute of Technology & Management
Operating principles:
The Control panel of the pantograph combines the raising and lowering functions with the over height
detection valve and air cylinder. The air system is very simple and is suitable for air supply pressures up
to 10 bars. The control panel is located inside the vehicle. The Control panel of the pantograph combines
the raising and lowering functions with the over height detection valve and air cylinder. To raise the
pantograph a minimum air supply of 3.8 bars is required though for guaranteed full contact wire force a
minimum pressure of 5.5 bars is required. To raise the pantograph the pan raise switch is operated
allowing air to the raising cylinder to operate the pantograph articulation and raise the pantograph
head. To lower, the pan lower switch is operated removing air supply to the cylinder, and exhausting
the system to lower the pantograph.
Workshop Sections of DMRCAxis Institute of Technology & Management
Pantograph Control Panel
Performance & Design Data:
Approximate Mass 128kg (Excluding foot insulators)
Pan Head Mass <11kg
Min Pressure to Raise 3.8 bar
Normal Pressure to Operate 5.5 bar
Workshop Sections of DMRCAxis Institute of Technology & Management
Pantograph
 VACCUM CIRCUIT BREAKER
The Vacuum Circuit Breaker (VCB) is a single pole, bi-directional high-speed AC circuit breaker. The
Vacuum Circuit Breaker consist of two porcelain weather-proof insulators mounted vertically, one
above the other, on a base plate which is fitted in the roof of the vehicle.
Location:
The Vacuum Circuit Breaker is located in the Roof of each DT car.
Function:
Its function is to isolate (open contacts) or connect (close contacts) the 25KV line to the train mounted
equipment. Being a circuit breaker, the VCB also isolates the train mounted equipment when an over
Carbon strip
thickness
should not be
less than 2mm
Raising and lowering
cylinder
Upper arm
Lower arm it
contains 4th
bar
inside it
Base
Insulators
Air feed
insulator
Potential
Transformer
Workshop Sections of DMRCAxis Institute of Technology & Management
current condition occurs due to a fault on the train or on the 25KV line. The fault detection is
determined by the Gate Control Unit.
Operating principles:
VCB Pneumatic Supply
Air enters the reservoir, via the air filter and the air pressure regulator. The supply air is then fed to the
relay-valve assembly and control governor pressure switch.
The pressure of the compressed air is regulated to 483 kPa by the regulator. The VCB control
governor switch contact is connected electrically in series with the magnet valve solenoid;
therefore the VCB will open automatically if the supply air pressure falls below the range of 345
kPa to 358 kPa. To close the VCB, the supply air pressure must exceed the range of 434 kPa to
448 kPa.
Workshop Sections of DMRCAxis Institute of Technology & Management
To close the main contacts of the VCB, the magnet valve is energized; this operates the relay valve. A
parallel air-supply is then fed directly through the relay valve into the cylinder.
As the main VCB piston moves, it operates the auxiliary contacts drive mechanism; which operates the
auxiliary contact block. The contact block comprise of three normally closed contacts and three
normally open contacts; these are connected as shown in the wiring diagram.
The actuator rod pushes against the mechanism below the vacuum interrupter. As the actuator rod
moves upwards, so does the drive plate and the spacers. This in turn moves the spring plate and
compresses the springs. The moving contact closes under the influence of atmospheric pressure acting
on the bellows. As soon as the contacts touch, the springs are compressed, giving an immediate increase
in contact force through the connector block, thereby minimizing contact bounce.
Simplified Air system diagram
Workshop Sections of DMRCAxis Institute of Technology & Management
The process continues until the drive plate bears against the connector block with the piston face
against the contacts. The mechanism is now charged, so that when air is discharged from the cylinder at
the start of the opening cycle, the springs force the spring plate to hit the connector block. This snatch
effect breaks any contact weld. Flexible shunts carry the current out from the moving contact to the
chromium-copper lower terminal casting.
Internal Structure of VCB
Technical Specifications:
Manufacturer ALSTOM
Voltage Rating 25,000 volts
Rated Current 1,000 amp
Short Circuit Breaking Current: 6,000 amp
Overall Height 700.5 mm
Workshop Sections of DMRCAxis Institute of Technology & Management
Overall Length 940 mm
Overall Width 430 mm
Weight 107 kg
 AC SURGE ARRESTOR
The Arrestor is described as a Gapless type, using a Zinc Oxide element. It is fully enclosed in porcelain
housing.
Location:
The AC Arrestor is located in the roof of each DT car.
Function:
The AC Arrestor is a device that protects the train-mounted equipment from excessive high voltage
transient conditions. Lightning strikes on the 25KV line usually causes these transient conditions.
Workshop Sections of DMRCAxis Institute of Technology & Management
Operating principles:
When a transient condition occurs, the AC Arrestor quickly becomes a low resistance path to earth and
the energy of the transient spike is absorbed. Once the spike is absorbed the AC Arrestor becomes a
high resistance path to earth. At system voltage levels the leakage current is less than 2mA.
Technical Specifications:
Manufacturer: OTOWA Electric
Nominal Voltage: 25,000 volts
Continuous Voltage: 33,000 volts
Rated Frequency: 50/60 Hz
Nominal Discharge Current: 10,000 A
Overall Height: 570 mm
Mass: 52 kg
Workshop Sections of DMRCAxis Institute of Technology & Management
 MAIN TRANSFORMER
The Main Transformer type ATM6 is 1170kVA, single phase, 50Hz, shell form type. The silicone oil,
which has excellent fire retardant characteristics, is used. This shell form type transformer has form fit
tank. The transformer cooling method is oil cooling. The oil absorbs the heat generated by the coil. An
oil pump circulates the oil around the windings to the radiator where it dissipates the absorbed heat.
Additional cooling is provided by a blower motor that forces cooling air through the radiator. Windings
are cooled by silicone oil that is circulated by oil pump. The rating of the transformer is specified at a line
voltage of 22.5kV.
Location:
Main transformer is located on the under frame of each trailer car.
Function:
The main transformer is utilized to supply all the electrical power requirements for the train.
Its purpose is to step down the 25kV catenary traction supply to voltage levels suitable for use by each
of the train supply system e.g. traction power and auxiliary power supplies.
Operating Principles:
The transformer comprises a single primary winding, connected to the over head line. Two secondary
windings stepping down to 1058V at a line voltage of 22.5kV are provided to feed the converter /
inverters. One tertiary winding stepping down to 470V at a line voltage of 22.5kV is provided to feed the
auxiliary static inverters.
Technical Specifications:
Windings Capacity Voltage Current
Workshop Sections of DMRCAxis Institute of Technology & Management
Primary 1170 KVA 22500 V 52 A
Secondary 976KVA 1058 V 513 A X 2 G
Tertiary 194 KVA 470 V 459 A
Oil Pump
Dial Type
Oil Cooler
Oil Pump
Exhaust
Filter
Breath
Shut
Workshop Sections of DMRCAxis Institute of Technology & Management
Main Pats of Main Transformer:
1. Oil Cooler:
Oil cooler is made of aluminium. Element of cooler consists of aluminium tube plate and corrugated fins.
The oil cooler is located at the side of main transformer's tank. The function of the oil cooler is to cool
the heated oil. The oil heated in the transformer is sent to the oil cooler by oil pump. In the oil cooler,
the heated oil is cooled by the heat exchange between oil and air flowed by blower.
2. Blower:
Blower is centrifugal and axial flow type. It consist of squirrel cage three phase induction motor, casing
and blade wheel. Blade wheel is directly attached to the motor axis, and simple construction. The
blower is located at the side of oil cooler of main transformer. The function of the blower is to blow air
to the oil cooler. The blower is used to blow air to the oil cooler. Blower's fan driven by a 3-phase motor
is used.
General Specifications:
 Cooling method used is Forced Oil, Forced Air KDAF
 Silicon Oil is used for cooling due to its fire retardant properties
 Oil volume of Transformer is 205 Litres
Workshop Sections of DMRCAxis Institute of Technology & Management
Technical specifications:
Power source: 3-phase, 415V, 50Hz
Revolution: 1430 r/min
Motor output: 1.5kW
3. Oil Pump
The oil pump is centrifugal type, direct coupled with the driving motor and fully enclosed in a housing.
The transformer oil serves for lubrication, cooling and insulation of the motor. The oil pump is located at
the pipe between transformer's tank and oil cooler. The function of the oil pump is to circulate oil of
transformer. The oil pump is used to circulate oil of transformer. Pump driven by a 3-phase motor is
used.
Technical specifications:
Power source: 3-phase, 415V, 50Hz
Oil circulation: 700 L/min
Operating oil temperature: 82 deg.C
Rated output: 1.5kW
Oil capacity: Approx. 7L
4. Dial Type Thermometer:
A dial type thermometer consists of bimetallic thermosensitive part and indicating part with electrical
alarm contact. A dial type thermometer indicates oil temperature. Because the well is a double tube,
thermometer can be replaced without draining the oil of transformer. A dial type thermometer is
located at the tank wall of main transformer. The function of the dial type thermometer is to detect an
abnormal temperature rise of oil. The dial type thermometer is mounted on the position where the oil
temperature can be accurately measured. The temperature element is composed by a spiral bimetal,
and changes the expansion into the rotation of the axis. When oil temperature exceeds the setting
value, the contact is closed.
Workshop Sections of DMRCAxis Institute of Technology & Management
Technical specifications:
Temperature range: -30 ~ 120 deg.C
Alarm value (with contact): 95 ± 2 deg.C
5. Oil Flow Relay
The winding temperature rises abnormally because the cooling performance of the winding decreases
when oil flow stops. When oil flow stops, it is not possible to protect the main transformer with the
thermometer because heat does not diffuse. Therefore, oil flow relay is mounted on the pipe between
oil pump and oil cooler.
When oil flow stops by oil pump failure, oil flow relay detects the stop of oil flow. It consists of driving
mechanism and alarm contact. When oil temperature exceeds the setting value, the contact is closed.
The function of oil flow relay is to detect the stop of oil flow.
6. Pressure Relief Valve
A self resetting type pressure relief valve is mounted on the tank wall. It is used to relieve abnormal
pressure which may occur due to abnormal operation of the traction converter and an accidental failure
of the transformer windings. The pressure relief valve is mounted on the tank wall of main transformer.
The function of pressure relief valve is to relieve abnormal pressure. This device is composed by the
valve, the link mechanism, and the spring. When inner pressure exceeds the setting value, the valve
operates immediately and discharges over-pressure. And when inner pressure become lower, the valve
closes automatically. Therefore, extra oil is prevented from flowing out.
Technical specifications:
Operating pressure: 0.1 ± 0.015 Mpa
7. Filter Breather
The transformer is always breathing as the oil level of conservator rise or falls with temperature changes,
and atmospheric moisture and dust are thereby drawn into the conservator. To prevent this, a filter
breather is installed on the air side connection type of conservator. There is an adsorbent and silicone
Workshop Sections of DMRCAxis Institute of Technology & Management
barthed glass cup. Because air goes in and out through this part, dust in air is removed. Therefore,
clean air is sent in the metallic bellows. A filter breather is installed on the air side connection pipe of
conservator. The function of filter breather is to send the clean air in the metallic bellows
 POTENTIAL TRANSFORMER
Location:
The Potential Transformer is located in the roof of each DT car.
Function:
The Potential Transformer PT is used to measure the voltage of the 25kv catenary line. The output of
the Potential Transformer PT is used as a control signal for the C/I Box control circuit. and the SIV box
control circuit.
Technical Specifications:
Manufacturer ALSTOM
Overall Height 533 mm
Overall Dia 326 mm
Weight 53 kg
Workshop Sections of DMRCAxis Institute of Technology & Management
PROPULSION SYSTEM
The Propulsion or traction system provides the tractive effort to accelerate the train and also provides
the electrical braking effort, which assists in the deceleration of the train. The propulsion system is
controlled by means of train line commands and a pulse width modulation (PWM) signal. The train line
commands and the PWM signal is controlled either by the driver using the master controller mounted in
the driver’s console. The PWM signal is an input torque demand signal into the Variable Voltage
Variable Frequency (VVVF) Inverter control unit. The output power to the Traction Motors is controlled
to match the PWM signal demand. In this way all the motorcars in the train will produce the same
tractive effort.
The traction system comprises the following main components:
a. AC Reactors (M car)
b. Converter / Inverter Box (M car)
c. Traction Motors.
The traction system can be described as a "Three-phase Drive" with VVVF control. The Converter carries
out the constant DC output voltage control and constant AC-side power factor control. The VVVF
Inverter output voltage waveform is a PWM type using Insulated Gate Bipolar Transistors (IGBT).
The traction command flows in the following manner –
TBC
PWM Generator
Converter/Inverter
Workshop Sections of DMRCAxis Institute of Technology & Management
PWM Signal
 AC REACTOR
The ac reactor operates in conjunction with the AC capacitor to provide the main line current filtering.
The ac reactor is air- cored type. The AC reactor and the AC Capacitor values have been chosen to have a
resonant value. The impedence of the circuit increases to reduce the level of harmonic currents flowing
in the circuit.
Location:
It is mounted on the under frame of M Car.
Technical specifications:
Manufacturer: Mitsubishi Electric
Voltage Rating: 952V ac
Inductance: 800 μH 15%
Continuous rating: 513A ac
Insulation
Cooling System: Natural cooling enhanced by train movement
(2m/second)
Overall Length: 765 mm
Traction Motor
Traction Power from MTR
Workshop Sections of DMRCAxis Institute of Technology & Management
 CONVERTER/INVERTER
Location:
The Converter / Inverter box is located in the middle of the under frame of each motor car. Access to
the Converter / Inverter unit is only possible from underneath the car.
Function:
The 25000V AC is supplied to the Main Transformer through VCB. Main Transformer supplies 1058V AC
to Converter unit. The converter converts 1058V ac obtained in the secondary windings of the main
transformer to a constant DC voltage of 1900V. This converter consists of the IGBT module with control
and self-protection function. The converter carries out PWM control, making it possible to make the
phase difference between the primary voltage and current of the main transformer a zero. In other
words, a power factor of 1.0 can be obtained. During regenerative brake operation, the converter is
also capable of inversely converting 1900V dc to 1058V ac, providing efficient powering and
regenerative operation without switching the main circuit. This 1900V DC is converted into 3 phase AC
variable voltage variable frequency by the inverter and supplied to Traction Motors. The inverter
controls the voltage applied to the Traction Motors to modify the tractive effort and controls the
frequency to change motor speed.
A constant slow speed operation is included into the VVVF control functions, which allows the driver to
select a desired train speed around 5 Km/h. The train will maintain this speed once selected until the
constant slow speed operation is cancelled. The Converter / Inverter responds to the train line
commands originating at the Master controller and Mode selector.
Overall Height: 600 mm
Overall Width: 700 mm
Mass: 230 kg
Workshop Sections of DMRCAxis Institute of Technology & Management
Block Diagram of Converter/Inverter:
Secondary winding
of MT
Converter
unit
Central block
contains OVCRf and
GR unit
Inverter unit
Traction
Motor
AC
Contactor
Gate control unit gives command to
all the indicated blocks as per the
parameters already set and input
coming from different sensors
DC link
Capacitor
Workshop Sections of DMRCAxis Institute of Technology & Management
CI Major Components:
This Converter / Inverter box consists of the following main equipment items,
 Converter unit (For conversion of a.c. input into 1900 V dc)
 Inverter unit (For inversion of 1900 V dc into three phase VVVF ac)
 Control unit (For controlling all the functions of C/I)
 AC contactor (It connects the input supply to the converter)
 Current transformer (For monitoring purpose)
 OVCRf unit (For quick discharging in case of over voltage, when MS
is OFF)
 GR control unit (For detecting the ground current)
 Charging parts (Charging diode, Charging transformer,
Charging AC contactor)
(For initial charging of converter IGBT’s)
 Power supply unit (For supplying power to the equipments inside
the C/I box)
 AC capacitor (For stabilising and filtering purpose)
Workshop Sections of DMRCAxis Institute of Technology & Management
CI Working Flow Chart:
Supply from M.T. secondary winding (952V-
1058V)
Supply from M.T. tertiary winding
(470V)
Charging circuit which contains step
up transformer and rectifier unit
Charging of filter capacitor up to
1500v
Contactor k1 closes if proper input is
available and there is no fault condition
Converter unit for conversion of AC to 1900V
DC
Filter reactor
DC link circuit, which consists of filter capacitor unit
Inverter unit, which changes 1900V DC to three phase variable voltage and variable
frequency output for the speed and torque control
Workshop Sections of DMRCAxis Institute of Technology & Management
Bolted Covers For
GR Unit Resistor
K Contactor
Inspection Cover Converter Power
Unit
Converter Power
Unit
1.1.1.1.1.1 Variable voltage and variable frequency to traction motor
Workshop Sections of DMRCAxis Institute of Technology & Management
MASTER CONTROLLER
Location:
The Master Controller is located in the driver’s console.
Function:
Gate Control Unit
Inspection Cover
Inverter Power
Unit
Inverter Power
Unit
Gate Control Units
Workshop Sections of DMRCAxis Institute of Technology & Management
(a) Selects the operational mode
(b) Generates the motoring and braking signals.
(c) Generates the PWM signal according to the position of the Master Controller handle.
(d) Provides the Deadman safety device.
System Controls:
The Mode Selector Switch is used to select the train-operating mode. There are five selectable positions,
which are:
 Off (OFF)
 Reverse (REV)
 Stand-By (STANBY)
 Forward (FOR)
 Automatic Train Protection (ATP)
Operating Principles:
To operate the Master Controller the driver’s key must be inserted and rotated to the unlocked
position. This releases the locking mechanism from the Mode Selector Switch and allows it to
be moved to the desired operating mode. Once the Mode Selector Switch has been moved
away from the Off position the driver’s key cannot be removed. The Master Controller Handle
can only be operated when the Mode Selector Switch is in one of the following positions:
 Reverse
 Stand-By (Only service braking and emergency braking)
 Forward
 ATP
The Mode Selector can only be moved when the Master Controller Handle is in the Bmax (full service
brake) position.
Design and Performance Data:
Manufacturer: Mitsubishi Electric
Workshop Sections of DMRCAxis Institute of Technology & Management
Overall Length: 310 mm
Overall Height: 166.5 mm
Overall Width 300 mm
Weight: 13 Kg
Regeneration of Power:
As soon as the train operator generates the braking command, the proportionate command also
goes to C/I. The inverter changes the stator frequency in such a way that the same motor starts
working as the generator and the energy generated is used in the retardation of the train. But
Electric braking effort varies in different speed range so to achieve the necessary retardation the
remaining braking effort is supplemented by the pneumatic brakes. This is known as brake
blending. This is made possible by intercommunication between C/I and BECU. The C/I
generates an equivalent analogue command for the electric braking effort and sends it to the
BECU of M-car, which further calculates the remaining braking effort.
The electric braking is available up to 5 kmph below this full braking effort is supplied as
friction brake. However this transition cannot occur instantaneously so a changeover period is
required as shown in the figure
C/I Brake Blending Characteristic
Speed
Braking
Effort
Electric
Brake
Pneumatic
Brake
0 km/h5 km/h10 km/h
Workshop Sections of DMRCAxis Institute of Technology & Management
 TRACTION MOTOR
Rotor Assembly
Speed
Sensor
Workshop Sections of DMRCAxis Institute of Technology & Management
The Traction Motor is a 220 kW, 4 pole, squirrel-cage, 3-phase self-ventilated induction motor. The
Traction Motor employs a Class 200 insulation system. The Traction Motor exterior is a frame-less type
with linking iron core clamps and a coupling plate. The motor frame is equipped with a vehicle fitting
nose and fitting seat.
A fan is mounted to the rotor shaft to draw air into the motor to provide cooling air to the rotor and
stator. The air enters the motor through the air inlet on the top of the non-drive end of the motor and
exits through the vents in the motor frame at the drive end of the motor. A Roller bearing is used on the
drive side of the rotor and Ball bearing is used on the non-drive side of the rotor.
Location:
Two 220kW Traction Motors are mounted on the transom of each motor car bogie
Function:
The Traction Motor provides the necessary torque to move the train. This torque is applied to each
wheel set in the motor cars via an axle-mounted gearbox, which is connected to the motor via a
coupling. The Traction Motor has the capacity to reduce the speed of the train by acting as a generator.
The momentum of the train causes the motor to rotate, and by adjusting the slip frequency in the
stator, the motor generates power back into the overhead supply. This causes a braking effect on the
train, which reduces the wear rate of the pneumatic brakes.
System controls:
Each motor car has four traction motors (two per bogie), with all four Traction Motors controlled by a
Variable Voltage Variable Frequency controller (VVVF).
Workshop Sections of DMRCAxis Institute of Technology & Management
Technical Specification:
Capacity 220KW
Voltage 1040V
Current 150A
Speed 2135 r/min
Freq 72.5 Hz
Poles 4
Mass 695kg
TRAIN INTEGRATED MANAGEMENT SYSTEM
The Train Integrated Management System (TIMS) provides a centralized function to monitor the train
borne systems and devices. It also provides the operators interface via a Video Display Unit mounted on
the operator desk. This display unit shows relevant information to the operator about the status of On
board equipment as well as commanded functions.
The Train Information Management System interfaces with the following systems located throughout
the train, these systems are:
 Traction Inverter (CI)
 Auxiliary Power Supply (SIV)
 Brake Electronic Control Unit (Brake System)
 Door Control Units
 Air conditioners
 AVAS & PA
Workshop Sections of DMRCAxis Institute of Technology & Management
 Train Radio
 ATC System
The Train Integrated Management System also monitors Train Line status, switch and circuit breaker
positions.
 FAULT DETECTION LEVELS
Fault detection is classified into five critically levels-
Level 1: Critical Fault
Faults that require the immediate action/attention of the train operator are classified as critical fault.
Level 2: Operating Event
An event which is triggered by the train operator.
Level 3: Maintenance Event
An event that requires the attention of maintenance staff, after the train has completed the scheduled
service operation.
Level 4: Record
A maintenance record that requires the attention of the maintenance staff during scheduled routine
maintenance
Level 5: Notice
Information or reminder to aid the train operator during normal service under defined conditions.
Notification and Recording of Events:
Fault Criticality Level
Level – I Level – II Level – III Level – IV Level – V
Pop Up X X
Departure X X
Workshop Sections of DMRCAxis Institute of Technology & Management
Current
Fault
X X
History X X
Memory X X X X X
 TIMS OPERATION MODES
Operator Mode Functions:
The TIMS system has the following functions which are accessible to the driver.
 System Check Screens - On this screen, TIMS will display on the main window a list of
Train faults that have been detected.
Workshop Sections of DMRCAxis Institute of Technology & Management
Additional information about other systems can be checked by driver by touching the soft keys at
the bottom of the screen display. The available soft keys and corresponding train systems are:
DOOR The status of Door system is displayed.
BRAKES The status of the Pneumatic Brake system is displayed.
POWER The status of the High Tension circuit and equipment is displayed.
AUX The status of the Auxiliary Power Supply System is displayed.
AIR CON The status of the Air Conditioning system is displayed.
HISTORY A list of previously record critical faults are displayed.
DEPARTURE The departure check screen is displayed.
MAIN The LOGOFF screen is displayed.
Workshop Sections of DMRCAxis Institute of Technology & Management
Maintenance Mode Functions:
The TIMS system functions available to the operator are also accessible to Maintenance staff. In
addition maintenance staff can also access the following functions.
 Data download / upload by TIMS Maintenance Terminal
 Data and status check on VDU
When the maintenance staff log on to the TIMS system, the Maintenance Menu screen is displayed.
From this screen maintenance staff can check or view the status of the TIMS system or equipment sub
system.
Workshop Sections of DMRCAxis Institute of Technology & Management
TIMS Equipment Locations:
Car Type
Equipment DT M
Central Unit X
Local Unit X
Display Unit X
Display Controller X
 TIMS EQUIPMENT DESCRIPTION
The Train Integrated Management System consists of the following equipment boxes located on
the Driving Trailer car and Motor car.
Central Unit:
The Central Unit carries out the application programs for the overall control and administration
of the TIMS system. The Central Unit has two central processor units (CPU1 & CPU2) Both
CPU's are operational and in case of one CPU failure the other CPU can continue the data
transmission function.
Workshop Sections of DMRCAxis Institute of Technology & Management
One central unit is provided in every DT car. The Central Unit is comprised of the following components:
 Sub Rack
 CPU 4 PCB
 CIF 4 PCB
 DIS2 PCB
 DIS 3 PCB
 AIO PCB
 PSG PCB
Local Unit:
The Local Unit is provided in each car to interface with various devices and intelligent train subsystems
such as Air Conditioning, Propulsion System, Auxiliary Supply System, Brake Electronic Control Unit and
Door Control Units. The Local Unit is comprised of the following components:
 Sub Rack
 CPU 4 PCB
 TRC 4 PCB
 DIS 2 PCB
Workshop Sections of DMRCAxis Institute of Technology & Management
 DIS 3 PCB
 PSG PCB
Display Controller
The Display Controller (DC)) is installed in DT car. The Display Controller is comprised of the
following:
 Line Filter
 DC – DC converter
 Connector
Video Display Unit:
The Video Display Unit has two main functions.
 To provide the Operator with information regarding the status of the various systems
throughout the train.
 To enable the Operator to quickly determine the nature of any subsystem failure and perform
the required actions to either rectify or isolate the fault.
Workshop Sections of DMRCAxis Institute of Technology & Management
PA/PIS SYSTEM
Circuit diagram
The PA and PIS System is powered up by input voltage of DC110V. The system is consisted of AVAU,
MOP, AOP, TNI and DIF which are installed in driver cabin PAMP, Loudspeaker, ETU, PAB, PIB which are
installed in saloon car.
Workshop Sections of DMRCAxis Institute of Technology & Management
Location:
The PA & PIS system location can be divided by two parts, the driver cabin and passenger saloon area.
The PA/PIS system consists of two basic systems
1. Visual System – Passenger Information System
2. Audio System – Automatic Voice announcement System
 VISUAL SYSTEM
 PASSENGER INFORMATION BOARD (PIB)
Location:
There are three PIB’s installed in each passenger saloon. All three are powered from the train battery
110V DC supply and continues to operate when traction power is lost.
Function:
The main function of the PIB’s is to provide information to the passengers. The PIB provides the
following information:
Workshop Sections of DMRCAxis Institute of Technology & Management
1. Next station is …. - inside train, on the PIB’s
2. This station is … - inside train, on the PIB’s
3. Journey message …..inside train, on the PIB’s
4. Real time information (visual only) - inside train, on the PIB’s (generated by OCC)
The Passenger Information Board (PIB) has a display matrix 32 (H) x 160(W) pixels. Both Hindi and
English messages can be scrolled on the display simultaneously and in synchronism. It is recommended
that for the automatic route announcements Hindi Characters are displayed in yellow and the English
characters in green. Emergency announcements may be displayed in red.
PIB consists of three main cards:
a) Interface Card: Used for communication between two cards within PIB.
b) Power Supply Card: It converts 110V DC to 5V DC by using SMPS(Switched Mode Power
Supply), now this 5V is send to interface card which further sends it to the third card i.e.
Control Card.
c) Control Card: It decodes the information given by AVAU (Automatic Voice
Announcement Unit) and displays on PIB.
Driver enters station AVAU PAMP information is
Code in MOP Displayed on PIB
Flow diagram
 DESTINATION IN FRONT OF TRAIN DISPLAY (DIF)
Location:
The single DIF is installed in each driver’s cab left window.
Function:
Workshop Sections of DMRCAxis Institute of Technology & Management
It displays train destination.
The LED matrix is 48 LED’s high by 96 LED’s wide. The matrix shall be used for two distinct lines, the
upper line for Hindi characters, and the lower line for English characters. The display shall check the
message to be displayed, independently for the Hindi line, and automatically size the message to make
the best fit.
The LED’s shall be yellow ultra bright types for sunlight legibility. The LED brightness shall be
automatically varied according to ambient light level measured by a light sensor at the front of the
display. The displays are powered by the train battery 110V DC supply.
 TRAIN NUMBER INDICATOR (TNI)
Location:
The single TNI is installed in each driver’s cab right window.
Function:
It is displays a four digit code. First two digits signify destination code and last two digits signify train no.
(E.g. 1234 here ‘12’ is the destination code and ‘34’ is train no).
The TNI is powered from 110V DC. The LED matrix is 32 LED’s high by 96 LED’s wide. The number shall
be four digit displayed with leading zero’s. The numeric characters shall be ‘multiple strike’ for
maximum visibility. The LED’s shall be yellow ultra bright types for sunlight legibility. The LED
Workshop Sections of DMRCAxis Institute of Technology & Management
brightness shall be automatically varied according to ambient light level measured by a light sensor at
the front of the display. The display area is 127 mm high by 383 mm wide
 Automatic Voice Announcement System (AVAU)
It is the heart of PA & PIS System and all functions are controlled by AVAU.
Location:
It is located in behind of the back wall in driver main console.
Function:
The system closely integrates the audio and visual (PIS) functions. The AVAU processor deals with the
basic audio.
Audio System:
The main functionality of the audio system is summarized in the following bullet points:
Workshop Sections of DMRCAxis Institute of Technology & Management
 Public Address – driver (active cab) to passengers (broadcast)
 Public Address – rear cab (inactive cab) to passengers (broadcast)
 Public Address – OCC (EPA) to passengers (broadcast)
 Public Address – Automatic announcement triggered automatically by the PIC, as a
result of input from ATO/ATP (including door open chime)
 Public Address – Automatic announcement manually triggered by driver on the MOP
 Public Address – Automatic Announcement manually triggered from rear cab MOP
 Cab to Cab communication (simplex) – Driver to all other cabs (including coupled
trains)
 Cab to cab communication (simplex) – Any cab to all other cabs (including coupled
trains)
 Passenger alarm warning tone
 Passenger Communication (simplex) – Driver to individual passenger, call set up as a
consequence of PAB operation.
 Door open/ closing chime
Workshop Sections of DMRCAxis Institute of Technology & Management
AVAU consists of following cards:
 Vehicle Communication Card
It is located at the first in upper card row of AVAU. The Vehicle Communications card is the serial
communications interface that is used by the AVAU.
 Cab Audio Communications Unit CPU Card
It is located at the fourth in upper card row of AVAU. This card is the central part of the AVAU system;
the processor on this card controls all AVAU functions. It comprises a memory card adapter and a solid-
state announcement record/ playback device for digitally stored announcements.
 Expanded Serial I/O Card
It is located at the 3rd in upper card row of AVAU. The Expanded serial I/O card provides additional
serial interfaces using the spare serial interface UART’s of the Vehicle Communications module.
Workshop Sections of DMRCAxis Institute of Technology & Management
 Audio Control Matrix Card
It is located at the 5th from left hand side in upper card row of AVAU. The Audio control matrix is a
central part of the AVAU; the card is responsible for switching and routing all of the audio signals.
 Front Panel Communications Card
It is located at the 2nd from right hand side in upper card row of AVAU. This card contains all of the
interface circuits to the AOP & MOP units.
 Analogue Train Wire Interface Card
It is located the 3rd from right hand side in upper card row of AVAU. This card is the major
external interface for signals from/ to the AVAU. The card includes audio line drivers and
receivers.
 Digital Train Wire Interface Card
It is located at the first from right hand side in upper card row of AVAU. This card is the major external
interface for digital signals from/ to the AVAU.
 Power Supply Interface Module
It is located at the 2nd from right hand side in lower card row of AVAU. This module takes the incoming
power supply from the train and provides filtering and transient suppression before the power is
provided to the main DC-DC converter.
 Main Power Supply DC-DC Converter Module
It is located at the first from right hand side in lower card row of AVAU. This is a proprietary DC-DC
converter. Power supply operates from the train battery supply (nominal 110V DC) and provides a
stable 24V DC output.
Workshop Sections of DMRCAxis Institute of Technology & Management
 Main Power Supply DC-DC Converter Module
It is located at the 3rd
from right hand side in lower card row of AVAU. This power supply card uses the
stable 24V output main supply to create multiple supply rails.
 Passenger Information System Control Card (PIC)
It is located at the 2nd
from left hand side in upper card row of
AVAU/PIC Rack. This card is the heart of the PIS system comprising
the communication control software for all PIS communications
equipment. Its primary function is the storage of a route database
complete with references for the audio system solid-state
announcements and visual messages for displays. These messages
are released in a controlled manner at specific trigger points
determined either by the input from ATO/ATP, or through manual
command via the MOP
 AUDIO SYSTEM
The main Components of audio system are as following :
 MAIN OPERATING PANEL (MOP)
The front panel is a polyester membrane over a steel plate, with apertures in the steel plate for button
caps, the loudspeaker and the LCD display .The membrane has a transparent window for the LCD display
and the membrane is acoustically transparent, allowing sound to be transmitted from the loud speaker
and protecting it from dust and moisture. Areas under the buttons have a transparent ring, allowing the
rear illumination to identify the location of each button at night.
It gives information about train ID. Command is send from MOP by driver to let the passengers know
about the next station which gets displayed on PIB. The MOP panel is connected in parallel with the
AOP panel.
Location:
It is installed on left hand side in the driver cabin.
Workshop Sections of DMRCAxis Institute of Technology & Management
The panel includes the following functional components:
- Keypad – 16 buttons
- Mode selection buttons, each with an associated with LED
- Backlighting for all the MOP buttons
- LCD graphics display – 64 X 192 pixels with LED back-light
- Loudspeaker
- 24V DC Power supply
- Red Button (PEA i.e. Passenger emergency alarm)
- Yellow Button(PA i.e. announcement in train)
- Blue Button(CC i.e. Cab to Cab communication) MOP
- Keypad Assembly
Functions:
a) Initialisation of Manual broadcasting such as special messages, emergency messages, station
name by train operator.
b) The train operator can talk to desired passenger who activated passenger Alarm System.
c) LCD Display for major function of operation.
d) For PAB indication, MOP Display shows the actual car number with PAB no.
e) Initialisation of Cab-to-Cab intercom.
Workshop Sections of DMRCAxis Institute of Technology & Management
 AOP (Auxiliary Operating Panel)
The AOP has a subset of the functions provided by the MOP. The
AOP comprises the mode selection controls for PA and Cab to
Cab.There is no keypad or LCD display. Passenger emergency
communication shall be controlled from the MOP only. A
loudspeaker is included on the AOP and this produces the same
audio that is produced by the MOP. It is connected with MOP in
parallel.
Location:
It is installed on right hand side in the driver cabin.
AOP
 EMERGENCY TALK BACK UNIT (ETU) & PASSENGER ALARM BUTTON
(PAB)
ETU PAB
Workshop Sections of DMRCAxis Institute of Technology & Management
In case of emergency if a passenger wants to talk to the driver he can do so with the help of ETU i.e.
EMERGENCY TALK BACK UNIT and PAB i.e. PASSENGER ALARM BUTTON.
The PAB is installed at each passenger exterior doorway. There are four PAB’s in each vehicle, associated
to doors L1 L2 R1 and R2. ETU is installed at each door position, with the microphone/loudspeaker
positioned approx 1.5m from the vehicle floor. We have four ETU’s in each car. It is provided as an
interface between the passenger and the driver. The Passenger can talk to the driver through the ETU.
As soon as the passenger presses PAB, ETU detects that PAB has been operated, and will identify this
condition to the PAMP. The PAMP then send signal to AVAU which further informs the driver by sending
information at MOP. Now driver is ready to talk to the passenger. The position of that particular ETU is
also displayed on MOP. The large red circular button is mechanically latched and is reset by inserting
and turning a square Carriage Key in a clockwise direction. The button is red in colour, having a central
part with the square key-hole; this central part is silver in colour.
ETU is installed at each door position, with the microphone/ loudspeaker positioned approx. 1.5m from
the vehicle floor. The ETU shall identify when a PAB has been activated.
Flow diagram:
PAB ETU PAMP AVAU MOP
 Loudspeaker & 100V line transformer
The loudspeaker can be driven with 4Watts of power, provided by the PAMP over the 100V line
distribution system.
Location:
It is installed with 6 sets in each saloon.
Workshop Sections of DMRCAxis Institute of Technology & Management
 PA Amplifier (PAMP)
The PAMP contains the audio power amplifier to drive the loudspeakers at 100V line level, and
monitors/ controls the four ETU’s in the same vehicle. The interfaces to the Train bus and saloon data-
bus (RS485) are through 3.5mm versions. It also controls the Vehicle data bus in that car, providing PIB’s
with data – received from the Train Data bus.
PAMP
Location:
PAMP is installed in the “Gangway Cubicle” in passenger saloon each.
Functions:
The PAMP contains the audio power amplifier to drive the loudspeakers at 100V line level, and
monitors/ controls the four ETU’s in the same vehicle. The PAMP is to be configured with the Car ID
(sequence number from the A end cab), as this is used as a WELNET system address. The PA power
amplifier incorporates the Whiteley SOALAS (Sound Operated Automatic Level Adjusting System)
whereby the loudspeaker system is used as a microphone when PA is not enabled, allowing the gain to
be set at the sampled ambient level in the 3 second period before the PA announcement commences.
 Switched Mode Power Supply (SMPS)
Workshop Sections of DMRCAxis Institute of Technology & Management
Like a linear power supply, the switched mode power supply too converts the available
unregulated ac or dc input voltage to a regulated dc output voltage. However in case of
SMPS with input supply drawn from the ac mains, the input voltage is first rectified and
filtered using a capacitor at the rectifier output. The unregulated dc voltage across the
capacitor is then fed to a high frequency dc-to-dc converter. Most of the dc-to-dc converters
used in SMPS circuits have an intermediate high frequency ac conversion stage to facilitate
the use of a high frequency transformer for voltage scaling and isolation. In contrast, in linear
power supplies with input voltage drawn from ac mains, the mains voltage is first stepped
down (and isolated) to the desired magnitude using a mains frequency transformer, followed
by rectification and filtering. The high frequency transformer used in a SMPS circuit is much
smaller in size and weight compared to the low frequency transformer of the linear power
supply circuit.
The ‘Switched Mode Power Supply’ owes its name to the dc-to-dc switching converter for
conversion from unregulated dc input voltage to regulated dc output voltage. The switch employed
is turned ‘ON’ and ‘OFF’ (referred as switching) at a high frequency. During ‘ON’ mode the switch is
in saturation mode with negligible voltage drop across the collector and emitter terminals of the
switch where as in ‘OFF’ mode the switch is in cut-off mode with negligible current through the
collector and emitter terminals. On the contrary the voltage-regulating switch, in a linear regulator
circuit, always remains in the active region.
Workshop Sections of DMRCAxis Institute of Technology & Management

Mais conteúdo relacionado

Mais procurados

Articulo subestaciones-bn
Articulo   subestaciones-bnArticulo   subestaciones-bn
Articulo subestaciones-bnjhonny_padilla
 
Halderman ch043 lecture
Halderman ch043 lectureHalderman ch043 lecture
Halderman ch043 lecturemcfalltj
 
On load tap changer in a.c. locomotive transformer &amp; air blast circuit b...
On load tap changer in a.c. locomotive transformer  &amp; air blast circuit b...On load tap changer in a.c. locomotive transformer  &amp; air blast circuit b...
On load tap changer in a.c. locomotive transformer &amp; air blast circuit b...vishalgohel12195
 
Vocational training Report (Train Lighting)
Vocational training Report (Train Lighting)Vocational training Report (Train Lighting)
Vocational training Report (Train Lighting)shovandey07
 
Electro hydraulic system Components and their operation
Electro hydraulic system Components and their operationElectro hydraulic system Components and their operation
Electro hydraulic system Components and their operationSrichandan Subudhi
 
Fire Pump Transfer Switch Basics
Fire Pump Transfer Switch BasicsFire Pump Transfer Switch Basics
Fire Pump Transfer Switch BasicsJames S Nasby
 
SUMMER TRAINNING REPORT ELECTRIC LOCOSHED KANPUR
SUMMER TRAINNING  REPORT ELECTRIC LOCOSHED  KANPURSUMMER TRAINNING  REPORT ELECTRIC LOCOSHED  KANPUR
SUMMER TRAINNING REPORT ELECTRIC LOCOSHED KANPURShivesh Ranjan
 
Pantograph I - Analysis on Pantographs & Traction Control
Pantograph I - Analysis on Pantographs & Traction ControlPantograph I - Analysis on Pantographs & Traction Control
Pantograph I - Analysis on Pantographs & Traction ControlKelvin Lam
 
Motor protection principles
Motor protection principlesMotor protection principles
Motor protection principlesAtiq Sayal
 
Diagnosing crd faults with a pressure tester
Diagnosing crd faults with a pressure testerDiagnosing crd faults with a pressure tester
Diagnosing crd faults with a pressure testerMas Tikno
 
4 hydraulic servo system
4 hydraulic servo system4 hydraulic servo system
4 hydraulic servo systemDr.R. SELVAM
 
Power Point Presentation For Symcom 2012
Power Point Presentation For Symcom 2012Power Point Presentation For Symcom 2012
Power Point Presentation For Symcom 2012Steve Johnson
 
WCR Kota junction internship ppt
WCR Kota junction internship pptWCR Kota junction internship ppt
WCR Kota junction internship pptSiddhantMishra43
 
Electric traction system
Electric traction systemElectric traction system
Electric traction systemAmitKumar6931
 
Chittaranjan locomotive works (Summer Training Report)
Chittaranjan locomotive works (Summer Training Report)Chittaranjan locomotive works (Summer Training Report)
Chittaranjan locomotive works (Summer Training Report)Deo Nath Jha
 
NWR summer training ppt
NWR summer training pptNWR summer training ppt
NWR summer training pptKaushu Deshwal
 

Mais procurados (20)

Articulo subestaciones-bn
Articulo   subestaciones-bnArticulo   subestaciones-bn
Articulo subestaciones-bn
 
Halderman ch043 lecture
Halderman ch043 lectureHalderman ch043 lecture
Halderman ch043 lecture
 
Ch11
Ch11Ch11
Ch11
 
On load tap changer in a.c. locomotive transformer &amp; air blast circuit b...
On load tap changer in a.c. locomotive transformer  &amp; air blast circuit b...On load tap changer in a.c. locomotive transformer  &amp; air blast circuit b...
On load tap changer in a.c. locomotive transformer &amp; air blast circuit b...
 
Vocational training Report (Train Lighting)
Vocational training Report (Train Lighting)Vocational training Report (Train Lighting)
Vocational training Report (Train Lighting)
 
Hydraulics training
Hydraulics trainingHydraulics training
Hydraulics training
 
Electro hydraulic system Components and their operation
Electro hydraulic system Components and their operationElectro hydraulic system Components and their operation
Electro hydraulic system Components and their operation
 
Fire Pump Transfer Switch Basics
Fire Pump Transfer Switch BasicsFire Pump Transfer Switch Basics
Fire Pump Transfer Switch Basics
 
SUMMER TRAINNING REPORT ELECTRIC LOCOSHED KANPUR
SUMMER TRAINNING  REPORT ELECTRIC LOCOSHED  KANPURSUMMER TRAINNING  REPORT ELECTRIC LOCOSHED  KANPUR
SUMMER TRAINNING REPORT ELECTRIC LOCOSHED KANPUR
 
Electrical traction
Electrical traction Electrical traction
Electrical traction
 
Pantograph I - Analysis on Pantographs & Traction Control
Pantograph I - Analysis on Pantographs & Traction ControlPantograph I - Analysis on Pantographs & Traction Control
Pantograph I - Analysis on Pantographs & Traction Control
 
Motor protection principles
Motor protection principlesMotor protection principles
Motor protection principles
 
Diagnosing crd faults with a pressure tester
Diagnosing crd faults with a pressure testerDiagnosing crd faults with a pressure tester
Diagnosing crd faults with a pressure tester
 
4 hydraulic servo system
4 hydraulic servo system4 hydraulic servo system
4 hydraulic servo system
 
Pneumatic c5
Pneumatic c5Pneumatic c5
Pneumatic c5
 
Power Point Presentation For Symcom 2012
Power Point Presentation For Symcom 2012Power Point Presentation For Symcom 2012
Power Point Presentation For Symcom 2012
 
WCR Kota junction internship ppt
WCR Kota junction internship pptWCR Kota junction internship ppt
WCR Kota junction internship ppt
 
Electric traction system
Electric traction systemElectric traction system
Electric traction system
 
Chittaranjan locomotive works (Summer Training Report)
Chittaranjan locomotive works (Summer Training Report)Chittaranjan locomotive works (Summer Training Report)
Chittaranjan locomotive works (Summer Training Report)
 
NWR summer training ppt
NWR summer training pptNWR summer training ppt
NWR summer training ppt
 

Destaque

Edificaciones Industriales
Edificaciones IndustrialesEdificaciones Industriales
Edificaciones Industrialesmileydis24
 
supreme broucher
supreme brouchersupreme broucher
supreme broucherEnda Conboy
 
Megan Luft Resume December
Megan Luft Resume DecemberMegan Luft Resume December
Megan Luft Resume DecemberMegan Luft
 
NUS Teaching Assistant Feedback: CS1010E (Andre Lim)
NUS Teaching Assistant Feedback: CS1010E (Andre Lim)NUS Teaching Assistant Feedback: CS1010E (Andre Lim)
NUS Teaching Assistant Feedback: CS1010E (Andre Lim)Andre Lim
 
Balantzea enpresa
Balantzea enpresaBalantzea enpresa
Balantzea enpresaautoa app
 
Como subir una presentación a slide share
Como subir una presentación a slide shareComo subir una presentación a slide share
Como subir una presentación a slide shareElyzabetth73
 
Rapidly variying flow
Rapidly variying flowRapidly variying flow
Rapidly variying flowMilan Sheta
 
องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้
องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้
องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้พัชรพล สุขาบูรณ์
 
Balantzea enpresa
Balantzea enpresaBalantzea enpresa
Balantzea enpresaautoa app
 
Jim McMullen Resume - 2017
Jim McMullen Resume - 2017Jim McMullen Resume - 2017
Jim McMullen Resume - 2017Jim McMullen
 
How to style the perfect lazy bun
How to style the perfect lazy bunHow to style the perfect lazy bun
How to style the perfect lazy bunDamion23
 

Destaque (16)

Edificaciones Industriales
Edificaciones IndustrialesEdificaciones Industriales
Edificaciones Industriales
 
supreme broucher
supreme brouchersupreme broucher
supreme broucher
 
Megan Luft Resume December
Megan Luft Resume DecemberMegan Luft Resume December
Megan Luft Resume December
 
NUS Teaching Assistant Feedback: CS1010E (Andre Lim)
NUS Teaching Assistant Feedback: CS1010E (Andre Lim)NUS Teaching Assistant Feedback: CS1010E (Andre Lim)
NUS Teaching Assistant Feedback: CS1010E (Andre Lim)
 
Balantzea enpresa
Balantzea enpresaBalantzea enpresa
Balantzea enpresa
 
Como subir una presentación a slide share
Como subir una presentación a slide shareComo subir una presentación a slide share
Como subir una presentación a slide share
 
Rapidly variying flow
Rapidly variying flowRapidly variying flow
Rapidly variying flow
 
Portafolio OAPE
Portafolio OAPEPortafolio OAPE
Portafolio OAPE
 
Inflación Diciembre 2015
Inflación Diciembre 2015Inflación Diciembre 2015
Inflación Diciembre 2015
 
องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้
องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้
องค์ประกอบคอมพิวเตอร์ งานสอนพรุ่งนี้
 
Balantzea enpresa
Balantzea enpresaBalantzea enpresa
Balantzea enpresa
 
Solar Power
Solar PowerSolar Power
Solar Power
 
Ibm SoMw
Ibm SoMwIbm SoMw
Ibm SoMw
 
Actividad 4 b
Actividad 4 bActividad 4 b
Actividad 4 b
 
Jim McMullen Resume - 2017
Jim McMullen Resume - 2017Jim McMullen Resume - 2017
Jim McMullen Resume - 2017
 
How to style the perfect lazy bun
How to style the perfect lazy bunHow to style the perfect lazy bun
How to style the perfect lazy bun
 

Semelhante a summer training report at dmrc by anoop

To design and fabrication of automatic pneumatic welding2
To design and fabrication of automatic pneumatic welding2To design and fabrication of automatic pneumatic welding2
To design and fabrication of automatic pneumatic welding2SANDEEP KUMAR
 
Noida Metro Rail Corporation
Noida Metro Rail CorporationNoida Metro Rail Corporation
Noida Metro Rail CorporationAnkit Chaudhary
 
Circuit breaker pert. 3
Circuit breaker pert. 3Circuit breaker pert. 3
Circuit breaker pert. 3Novia Putri
 
Railway workshop jodhpur
Railway workshop jodhpurRailway workshop jodhpur
Railway workshop jodhpurMAHESH SONI
 
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vnLs catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vnDien Ha The
 
60015688 ashish-loco-summer (1)
60015688 ashish-loco-summer (1)60015688 ashish-loco-summer (1)
60015688 ashish-loco-summer (1)99sunilkumar
 
railway workshop jodhpur
railway workshop jodhpurrailway workshop jodhpur
railway workshop jodhpurkalumutha
 
railway workshop jodhpur
railway workshop jodhpur railway workshop jodhpur
railway workshop jodhpur kalumutha
 
Automatic voltage regulator(avr)
Automatic voltage regulator(avr)Automatic voltage regulator(avr)
Automatic voltage regulator(avr)JoeChueng
 
Automatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage boosterAutomatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage boosterJestem Zhou
 
TC-MODULE – 2.pdf
TC-MODULE – 2.pdfTC-MODULE – 2.pdf
TC-MODULE – 2.pdfNayan351985
 
IRJET - Design of Semiautomatic Vacuum Elevators
IRJET - Design of Semiautomatic Vacuum ElevatorsIRJET - Design of Semiautomatic Vacuum Elevators
IRJET - Design of Semiautomatic Vacuum ElevatorsIRJET Journal
 
Catalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji ElectricCatalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji ElectricCTY TNHH HẠO PHƯƠNG
 
Electric Traction System benefits and different types of electric traction sy...
Electric Traction System benefits and different types of electric traction sy...Electric Traction System benefits and different types of electric traction sy...
Electric Traction System benefits and different types of electric traction sy...ravi9898000178
 
1550091 634842733511023750
1550091 6348427335110237501550091 634842733511023750
1550091 634842733511023750Mdtarique Anwar
 
牵引变流器(CI).ppt
牵引变流器(CI).ppt牵引变流器(CI).ppt
牵引变流器(CI).pptNajihah Ab.
 

Semelhante a summer training report at dmrc by anoop (20)

To design and fabrication of automatic pneumatic welding2
To design and fabrication of automatic pneumatic welding2To design and fabrication of automatic pneumatic welding2
To design and fabrication of automatic pneumatic welding2
 
Noida Metro Rail Corporation
Noida Metro Rail CorporationNoida Metro Rail Corporation
Noida Metro Rail Corporation
 
Doorpneu plc 2014
Doorpneu  plc 2014Doorpneu  plc 2014
Doorpneu plc 2014
 
Circuit breaker pert. 3
Circuit breaker pert. 3Circuit breaker pert. 3
Circuit breaker pert. 3
 
Railway workshop jodhpur
Railway workshop jodhpurRailway workshop jodhpur
Railway workshop jodhpur
 
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vnLs catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
 
60015688 ashish-loco-summer (1)
60015688 ashish-loco-summer (1)60015688 ashish-loco-summer (1)
60015688 ashish-loco-summer (1)
 
Air engine 2014
Air engine 2014Air engine 2014
Air engine 2014
 
railway workshop jodhpur
railway workshop jodhpurrailway workshop jodhpur
railway workshop jodhpur
 
railway workshop jodhpur
railway workshop jodhpur railway workshop jodhpur
railway workshop jodhpur
 
Automatic voltage regulator(avr)
Automatic voltage regulator(avr)Automatic voltage regulator(avr)
Automatic voltage regulator(avr)
 
Automatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage boosterAutomatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage booster
 
TC-MODULE – 2.pdf
TC-MODULE – 2.pdfTC-MODULE – 2.pdf
TC-MODULE – 2.pdf
 
IRJET - Design of Semiautomatic Vacuum Elevators
IRJET - Design of Semiautomatic Vacuum ElevatorsIRJET - Design of Semiautomatic Vacuum Elevators
IRJET - Design of Semiautomatic Vacuum Elevators
 
Catalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji ElectricCatalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji Electric
 
Electric Traction System benefits and different types of electric traction sy...
Electric Traction System benefits and different types of electric traction sy...Electric Traction System benefits and different types of electric traction sy...
Electric Traction System benefits and different types of electric traction sy...
 
Moisture controller report total
Moisture controller report totalMoisture controller report total
Moisture controller report total
 
ceiling fan
 ceiling fan  ceiling fan
ceiling fan
 
1550091 634842733511023750
1550091 6348427335110237501550091 634842733511023750
1550091 634842733511023750
 
牵引变流器(CI).ppt
牵引变流器(CI).ppt牵引变流器(CI).ppt
牵引变流器(CI).ppt
 

summer training report at dmrc by anoop

  • 1. Summer Training Report Delhi Metro Rail Corporation (DMRC) Submitted by: ANOOP KUMAR Workshop Sections of DMRC
  • 2. CERTIFICATE This is to certify that the summer Training Report entitled “DELHI METRO RAIL CORPORATIO LTD.” done by Mr. Anoop kumar, Roll No 1371931011 to the Electronics and Communication Engineering is an authentic work carried out by him at Axis Institute of Technology and Management, under my guidance. Date: Signature of the Guide Workshop Sections of DMRC
  • 3. Made in Indian Metro A $590 million contract for over 400 coaches for phase II has been awarded to BOMBARDIER. While initial trains will be manufactured in Germany and Sweden, the remainder will be built at Bombardier's Indian factory in Savli, near Vadodara (Gujrat). Current Routes LINE 1 (Dilshad Garden to Rithala via Kashmeri Gate) LINE 2 (HUDA City Centre (Gurgaon) to Jahangirpuri via Rajiv Chowk & Kashmere Gate) LINE 3 (Noida City Centre to Dwarka Sector 21 via Rajiv Chowk and Yamuna Bank) LINE 4 (Yamuna Bank to Anand Vihar ISBT) LINE 5 (Inderlok to Mundka) LINE 6 (Central Secretariat to Badarpur) LINE 7 (Airport METRO Express Line) TRAIN FORMATION At present each train-set consists of four cars. Both ends of the train-set are driving trailer car and middle cars are motor cars. The trailer cars are defined as "DT" car and motor cars are defined as "M" car. The train-set can be controlled as a complete unit or as separate units for various maintenance activities at the depot. 1) 4 car - DT-M-M-DT 2) 6 Car – DT-M-M-T-M-DT 3) 8 Car – DT-M-M-T-M-T-M-DT SALIENT FEATURE 1. Broad Gauge 2. 25 KV Supply Voltage System 3. Light Weight Stainless Steel Structure 4. Three phase A.C. Induction Motor 5. Fail safe braking system with regenerative Braking 6. VVVF Control 7. Reinforced conical rubber primary suspension 8. Secondary Air Suspension 9. Uniform Floor Height 10. Jerk Controlled Braking 11. Slip/Slide protection 12. Train Integrated Management System 13. PLC based saloon Air-conditioning system 14. Electrically Operated and electronically controlled Saloon Doors Workshop Sections of DMRCAxis Institute of Technology & Management
  • 4. 15. Emergency Door 16. ATP/ATO HIGH TENSION SYSTEM The high tension system consists of the following system/equipments. 1. Pantograph 2. Vacuum Circuit Breaker 3. Surge Arrestor 4. Main Transformer 5. Potential Transformer The pantograph connects the train electrical system to the overhead current (OHC) supply. The 25000V AC is supplied to the Main Transformer through VCB. The flow of power becomes as under. Flow of Power: OHE Pantograph VCB Main Transformer C/I SIV Traction Motor Aircon Main compressor 110 V load 220V Load Gear case Power to Wheels Oil pump and blower Workshop Sections of DMRCAxis Institute of Technology & Management
  • 5.  PANTOGRAPH Location: The Pantograph is located on top of the Vehicle roof structure to allow unhindered access to the overhead lines. Function: The function is to collect the current from the overhead wire by the carbons, which is carried by the structural members of the unit to the power take off points on the base frame. The insulated bearings, are by passed by the flexible shunts. The pantograph is attached via 4 foot insulators that support and insulate the pantograph on the vehicle roof. The Pantograph receives an air supply from the vehicle via the control panel and air feed insulator allowing the pantograph to be raised and lowered on demand and maintain contact force with the overhead wire when in the raised operational mode. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 6. Operating principles: The Control panel of the pantograph combines the raising and lowering functions with the over height detection valve and air cylinder. The air system is very simple and is suitable for air supply pressures up to 10 bars. The control panel is located inside the vehicle. The Control panel of the pantograph combines the raising and lowering functions with the over height detection valve and air cylinder. To raise the pantograph a minimum air supply of 3.8 bars is required though for guaranteed full contact wire force a minimum pressure of 5.5 bars is required. To raise the pantograph the pan raise switch is operated allowing air to the raising cylinder to operate the pantograph articulation and raise the pantograph head. To lower, the pan lower switch is operated removing air supply to the cylinder, and exhausting the system to lower the pantograph. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 7. Pantograph Control Panel Performance & Design Data: Approximate Mass 128kg (Excluding foot insulators) Pan Head Mass <11kg Min Pressure to Raise 3.8 bar Normal Pressure to Operate 5.5 bar Workshop Sections of DMRCAxis Institute of Technology & Management
  • 8. Pantograph  VACCUM CIRCUIT BREAKER The Vacuum Circuit Breaker (VCB) is a single pole, bi-directional high-speed AC circuit breaker. The Vacuum Circuit Breaker consist of two porcelain weather-proof insulators mounted vertically, one above the other, on a base plate which is fitted in the roof of the vehicle. Location: The Vacuum Circuit Breaker is located in the Roof of each DT car. Function: Its function is to isolate (open contacts) or connect (close contacts) the 25KV line to the train mounted equipment. Being a circuit breaker, the VCB also isolates the train mounted equipment when an over Carbon strip thickness should not be less than 2mm Raising and lowering cylinder Upper arm Lower arm it contains 4th bar inside it Base Insulators Air feed insulator Potential Transformer Workshop Sections of DMRCAxis Institute of Technology & Management
  • 9. current condition occurs due to a fault on the train or on the 25KV line. The fault detection is determined by the Gate Control Unit. Operating principles: VCB Pneumatic Supply Air enters the reservoir, via the air filter and the air pressure regulator. The supply air is then fed to the relay-valve assembly and control governor pressure switch. The pressure of the compressed air is regulated to 483 kPa by the regulator. The VCB control governor switch contact is connected electrically in series with the magnet valve solenoid; therefore the VCB will open automatically if the supply air pressure falls below the range of 345 kPa to 358 kPa. To close the VCB, the supply air pressure must exceed the range of 434 kPa to 448 kPa. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 10. To close the main contacts of the VCB, the magnet valve is energized; this operates the relay valve. A parallel air-supply is then fed directly through the relay valve into the cylinder. As the main VCB piston moves, it operates the auxiliary contacts drive mechanism; which operates the auxiliary contact block. The contact block comprise of three normally closed contacts and three normally open contacts; these are connected as shown in the wiring diagram. The actuator rod pushes against the mechanism below the vacuum interrupter. As the actuator rod moves upwards, so does the drive plate and the spacers. This in turn moves the spring plate and compresses the springs. The moving contact closes under the influence of atmospheric pressure acting on the bellows. As soon as the contacts touch, the springs are compressed, giving an immediate increase in contact force through the connector block, thereby minimizing contact bounce. Simplified Air system diagram Workshop Sections of DMRCAxis Institute of Technology & Management
  • 11. The process continues until the drive plate bears against the connector block with the piston face against the contacts. The mechanism is now charged, so that when air is discharged from the cylinder at the start of the opening cycle, the springs force the spring plate to hit the connector block. This snatch effect breaks any contact weld. Flexible shunts carry the current out from the moving contact to the chromium-copper lower terminal casting. Internal Structure of VCB Technical Specifications: Manufacturer ALSTOM Voltage Rating 25,000 volts Rated Current 1,000 amp Short Circuit Breaking Current: 6,000 amp Overall Height 700.5 mm Workshop Sections of DMRCAxis Institute of Technology & Management
  • 12. Overall Length 940 mm Overall Width 430 mm Weight 107 kg  AC SURGE ARRESTOR The Arrestor is described as a Gapless type, using a Zinc Oxide element. It is fully enclosed in porcelain housing. Location: The AC Arrestor is located in the roof of each DT car. Function: The AC Arrestor is a device that protects the train-mounted equipment from excessive high voltage transient conditions. Lightning strikes on the 25KV line usually causes these transient conditions. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 13. Operating principles: When a transient condition occurs, the AC Arrestor quickly becomes a low resistance path to earth and the energy of the transient spike is absorbed. Once the spike is absorbed the AC Arrestor becomes a high resistance path to earth. At system voltage levels the leakage current is less than 2mA. Technical Specifications: Manufacturer: OTOWA Electric Nominal Voltage: 25,000 volts Continuous Voltage: 33,000 volts Rated Frequency: 50/60 Hz Nominal Discharge Current: 10,000 A Overall Height: 570 mm Mass: 52 kg Workshop Sections of DMRCAxis Institute of Technology & Management
  • 14.  MAIN TRANSFORMER The Main Transformer type ATM6 is 1170kVA, single phase, 50Hz, shell form type. The silicone oil, which has excellent fire retardant characteristics, is used. This shell form type transformer has form fit tank. The transformer cooling method is oil cooling. The oil absorbs the heat generated by the coil. An oil pump circulates the oil around the windings to the radiator where it dissipates the absorbed heat. Additional cooling is provided by a blower motor that forces cooling air through the radiator. Windings are cooled by silicone oil that is circulated by oil pump. The rating of the transformer is specified at a line voltage of 22.5kV. Location: Main transformer is located on the under frame of each trailer car. Function: The main transformer is utilized to supply all the electrical power requirements for the train. Its purpose is to step down the 25kV catenary traction supply to voltage levels suitable for use by each of the train supply system e.g. traction power and auxiliary power supplies. Operating Principles: The transformer comprises a single primary winding, connected to the over head line. Two secondary windings stepping down to 1058V at a line voltage of 22.5kV are provided to feed the converter / inverters. One tertiary winding stepping down to 470V at a line voltage of 22.5kV is provided to feed the auxiliary static inverters. Technical Specifications: Windings Capacity Voltage Current Workshop Sections of DMRCAxis Institute of Technology & Management
  • 15. Primary 1170 KVA 22500 V 52 A Secondary 976KVA 1058 V 513 A X 2 G Tertiary 194 KVA 470 V 459 A Oil Pump Dial Type Oil Cooler Oil Pump Exhaust Filter Breath Shut Workshop Sections of DMRCAxis Institute of Technology & Management
  • 16. Main Pats of Main Transformer: 1. Oil Cooler: Oil cooler is made of aluminium. Element of cooler consists of aluminium tube plate and corrugated fins. The oil cooler is located at the side of main transformer's tank. The function of the oil cooler is to cool the heated oil. The oil heated in the transformer is sent to the oil cooler by oil pump. In the oil cooler, the heated oil is cooled by the heat exchange between oil and air flowed by blower. 2. Blower: Blower is centrifugal and axial flow type. It consist of squirrel cage three phase induction motor, casing and blade wheel. Blade wheel is directly attached to the motor axis, and simple construction. The blower is located at the side of oil cooler of main transformer. The function of the blower is to blow air to the oil cooler. The blower is used to blow air to the oil cooler. Blower's fan driven by a 3-phase motor is used. General Specifications:  Cooling method used is Forced Oil, Forced Air KDAF  Silicon Oil is used for cooling due to its fire retardant properties  Oil volume of Transformer is 205 Litres Workshop Sections of DMRCAxis Institute of Technology & Management
  • 17. Technical specifications: Power source: 3-phase, 415V, 50Hz Revolution: 1430 r/min Motor output: 1.5kW 3. Oil Pump The oil pump is centrifugal type, direct coupled with the driving motor and fully enclosed in a housing. The transformer oil serves for lubrication, cooling and insulation of the motor. The oil pump is located at the pipe between transformer's tank and oil cooler. The function of the oil pump is to circulate oil of transformer. The oil pump is used to circulate oil of transformer. Pump driven by a 3-phase motor is used. Technical specifications: Power source: 3-phase, 415V, 50Hz Oil circulation: 700 L/min Operating oil temperature: 82 deg.C Rated output: 1.5kW Oil capacity: Approx. 7L 4. Dial Type Thermometer: A dial type thermometer consists of bimetallic thermosensitive part and indicating part with electrical alarm contact. A dial type thermometer indicates oil temperature. Because the well is a double tube, thermometer can be replaced without draining the oil of transformer. A dial type thermometer is located at the tank wall of main transformer. The function of the dial type thermometer is to detect an abnormal temperature rise of oil. The dial type thermometer is mounted on the position where the oil temperature can be accurately measured. The temperature element is composed by a spiral bimetal, and changes the expansion into the rotation of the axis. When oil temperature exceeds the setting value, the contact is closed. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 18. Technical specifications: Temperature range: -30 ~ 120 deg.C Alarm value (with contact): 95 ± 2 deg.C 5. Oil Flow Relay The winding temperature rises abnormally because the cooling performance of the winding decreases when oil flow stops. When oil flow stops, it is not possible to protect the main transformer with the thermometer because heat does not diffuse. Therefore, oil flow relay is mounted on the pipe between oil pump and oil cooler. When oil flow stops by oil pump failure, oil flow relay detects the stop of oil flow. It consists of driving mechanism and alarm contact. When oil temperature exceeds the setting value, the contact is closed. The function of oil flow relay is to detect the stop of oil flow. 6. Pressure Relief Valve A self resetting type pressure relief valve is mounted on the tank wall. It is used to relieve abnormal pressure which may occur due to abnormal operation of the traction converter and an accidental failure of the transformer windings. The pressure relief valve is mounted on the tank wall of main transformer. The function of pressure relief valve is to relieve abnormal pressure. This device is composed by the valve, the link mechanism, and the spring. When inner pressure exceeds the setting value, the valve operates immediately and discharges over-pressure. And when inner pressure become lower, the valve closes automatically. Therefore, extra oil is prevented from flowing out. Technical specifications: Operating pressure: 0.1 ± 0.015 Mpa 7. Filter Breather The transformer is always breathing as the oil level of conservator rise or falls with temperature changes, and atmospheric moisture and dust are thereby drawn into the conservator. To prevent this, a filter breather is installed on the air side connection type of conservator. There is an adsorbent and silicone Workshop Sections of DMRCAxis Institute of Technology & Management
  • 19. barthed glass cup. Because air goes in and out through this part, dust in air is removed. Therefore, clean air is sent in the metallic bellows. A filter breather is installed on the air side connection pipe of conservator. The function of filter breather is to send the clean air in the metallic bellows  POTENTIAL TRANSFORMER Location: The Potential Transformer is located in the roof of each DT car. Function: The Potential Transformer PT is used to measure the voltage of the 25kv catenary line. The output of the Potential Transformer PT is used as a control signal for the C/I Box control circuit. and the SIV box control circuit. Technical Specifications: Manufacturer ALSTOM Overall Height 533 mm Overall Dia 326 mm Weight 53 kg Workshop Sections of DMRCAxis Institute of Technology & Management
  • 20. PROPULSION SYSTEM The Propulsion or traction system provides the tractive effort to accelerate the train and also provides the electrical braking effort, which assists in the deceleration of the train. The propulsion system is controlled by means of train line commands and a pulse width modulation (PWM) signal. The train line commands and the PWM signal is controlled either by the driver using the master controller mounted in the driver’s console. The PWM signal is an input torque demand signal into the Variable Voltage Variable Frequency (VVVF) Inverter control unit. The output power to the Traction Motors is controlled to match the PWM signal demand. In this way all the motorcars in the train will produce the same tractive effort. The traction system comprises the following main components: a. AC Reactors (M car) b. Converter / Inverter Box (M car) c. Traction Motors. The traction system can be described as a "Three-phase Drive" with VVVF control. The Converter carries out the constant DC output voltage control and constant AC-side power factor control. The VVVF Inverter output voltage waveform is a PWM type using Insulated Gate Bipolar Transistors (IGBT). The traction command flows in the following manner – TBC PWM Generator Converter/Inverter Workshop Sections of DMRCAxis Institute of Technology & Management
  • 21. PWM Signal  AC REACTOR The ac reactor operates in conjunction with the AC capacitor to provide the main line current filtering. The ac reactor is air- cored type. The AC reactor and the AC Capacitor values have been chosen to have a resonant value. The impedence of the circuit increases to reduce the level of harmonic currents flowing in the circuit. Location: It is mounted on the under frame of M Car. Technical specifications: Manufacturer: Mitsubishi Electric Voltage Rating: 952V ac Inductance: 800 μH 15% Continuous rating: 513A ac Insulation Cooling System: Natural cooling enhanced by train movement (2m/second) Overall Length: 765 mm Traction Motor Traction Power from MTR Workshop Sections of DMRCAxis Institute of Technology & Management
  • 22.  CONVERTER/INVERTER Location: The Converter / Inverter box is located in the middle of the under frame of each motor car. Access to the Converter / Inverter unit is only possible from underneath the car. Function: The 25000V AC is supplied to the Main Transformer through VCB. Main Transformer supplies 1058V AC to Converter unit. The converter converts 1058V ac obtained in the secondary windings of the main transformer to a constant DC voltage of 1900V. This converter consists of the IGBT module with control and self-protection function. The converter carries out PWM control, making it possible to make the phase difference between the primary voltage and current of the main transformer a zero. In other words, a power factor of 1.0 can be obtained. During regenerative brake operation, the converter is also capable of inversely converting 1900V dc to 1058V ac, providing efficient powering and regenerative operation without switching the main circuit. This 1900V DC is converted into 3 phase AC variable voltage variable frequency by the inverter and supplied to Traction Motors. The inverter controls the voltage applied to the Traction Motors to modify the tractive effort and controls the frequency to change motor speed. A constant slow speed operation is included into the VVVF control functions, which allows the driver to select a desired train speed around 5 Km/h. The train will maintain this speed once selected until the constant slow speed operation is cancelled. The Converter / Inverter responds to the train line commands originating at the Master controller and Mode selector. Overall Height: 600 mm Overall Width: 700 mm Mass: 230 kg Workshop Sections of DMRCAxis Institute of Technology & Management
  • 23. Block Diagram of Converter/Inverter: Secondary winding of MT Converter unit Central block contains OVCRf and GR unit Inverter unit Traction Motor AC Contactor Gate control unit gives command to all the indicated blocks as per the parameters already set and input coming from different sensors DC link Capacitor Workshop Sections of DMRCAxis Institute of Technology & Management
  • 24. CI Major Components: This Converter / Inverter box consists of the following main equipment items,  Converter unit (For conversion of a.c. input into 1900 V dc)  Inverter unit (For inversion of 1900 V dc into three phase VVVF ac)  Control unit (For controlling all the functions of C/I)  AC contactor (It connects the input supply to the converter)  Current transformer (For monitoring purpose)  OVCRf unit (For quick discharging in case of over voltage, when MS is OFF)  GR control unit (For detecting the ground current)  Charging parts (Charging diode, Charging transformer, Charging AC contactor) (For initial charging of converter IGBT’s)  Power supply unit (For supplying power to the equipments inside the C/I box)  AC capacitor (For stabilising and filtering purpose) Workshop Sections of DMRCAxis Institute of Technology & Management
  • 25. CI Working Flow Chart: Supply from M.T. secondary winding (952V- 1058V) Supply from M.T. tertiary winding (470V) Charging circuit which contains step up transformer and rectifier unit Charging of filter capacitor up to 1500v Contactor k1 closes if proper input is available and there is no fault condition Converter unit for conversion of AC to 1900V DC Filter reactor DC link circuit, which consists of filter capacitor unit Inverter unit, which changes 1900V DC to three phase variable voltage and variable frequency output for the speed and torque control Workshop Sections of DMRCAxis Institute of Technology & Management
  • 26. Bolted Covers For GR Unit Resistor K Contactor Inspection Cover Converter Power Unit Converter Power Unit 1.1.1.1.1.1 Variable voltage and variable frequency to traction motor Workshop Sections of DMRCAxis Institute of Technology & Management
  • 27. MASTER CONTROLLER Location: The Master Controller is located in the driver’s console. Function: Gate Control Unit Inspection Cover Inverter Power Unit Inverter Power Unit Gate Control Units Workshop Sections of DMRCAxis Institute of Technology & Management
  • 28. (a) Selects the operational mode (b) Generates the motoring and braking signals. (c) Generates the PWM signal according to the position of the Master Controller handle. (d) Provides the Deadman safety device. System Controls: The Mode Selector Switch is used to select the train-operating mode. There are five selectable positions, which are:  Off (OFF)  Reverse (REV)  Stand-By (STANBY)  Forward (FOR)  Automatic Train Protection (ATP) Operating Principles: To operate the Master Controller the driver’s key must be inserted and rotated to the unlocked position. This releases the locking mechanism from the Mode Selector Switch and allows it to be moved to the desired operating mode. Once the Mode Selector Switch has been moved away from the Off position the driver’s key cannot be removed. The Master Controller Handle can only be operated when the Mode Selector Switch is in one of the following positions:  Reverse  Stand-By (Only service braking and emergency braking)  Forward  ATP The Mode Selector can only be moved when the Master Controller Handle is in the Bmax (full service brake) position. Design and Performance Data: Manufacturer: Mitsubishi Electric Workshop Sections of DMRCAxis Institute of Technology & Management
  • 29. Overall Length: 310 mm Overall Height: 166.5 mm Overall Width 300 mm Weight: 13 Kg Regeneration of Power: As soon as the train operator generates the braking command, the proportionate command also goes to C/I. The inverter changes the stator frequency in such a way that the same motor starts working as the generator and the energy generated is used in the retardation of the train. But Electric braking effort varies in different speed range so to achieve the necessary retardation the remaining braking effort is supplemented by the pneumatic brakes. This is known as brake blending. This is made possible by intercommunication between C/I and BECU. The C/I generates an equivalent analogue command for the electric braking effort and sends it to the BECU of M-car, which further calculates the remaining braking effort. The electric braking is available up to 5 kmph below this full braking effort is supplied as friction brake. However this transition cannot occur instantaneously so a changeover period is required as shown in the figure C/I Brake Blending Characteristic Speed Braking Effort Electric Brake Pneumatic Brake 0 km/h5 km/h10 km/h Workshop Sections of DMRCAxis Institute of Technology & Management
  • 30.  TRACTION MOTOR Rotor Assembly Speed Sensor Workshop Sections of DMRCAxis Institute of Technology & Management
  • 31. The Traction Motor is a 220 kW, 4 pole, squirrel-cage, 3-phase self-ventilated induction motor. The Traction Motor employs a Class 200 insulation system. The Traction Motor exterior is a frame-less type with linking iron core clamps and a coupling plate. The motor frame is equipped with a vehicle fitting nose and fitting seat. A fan is mounted to the rotor shaft to draw air into the motor to provide cooling air to the rotor and stator. The air enters the motor through the air inlet on the top of the non-drive end of the motor and exits through the vents in the motor frame at the drive end of the motor. A Roller bearing is used on the drive side of the rotor and Ball bearing is used on the non-drive side of the rotor. Location: Two 220kW Traction Motors are mounted on the transom of each motor car bogie Function: The Traction Motor provides the necessary torque to move the train. This torque is applied to each wheel set in the motor cars via an axle-mounted gearbox, which is connected to the motor via a coupling. The Traction Motor has the capacity to reduce the speed of the train by acting as a generator. The momentum of the train causes the motor to rotate, and by adjusting the slip frequency in the stator, the motor generates power back into the overhead supply. This causes a braking effect on the train, which reduces the wear rate of the pneumatic brakes. System controls: Each motor car has four traction motors (two per bogie), with all four Traction Motors controlled by a Variable Voltage Variable Frequency controller (VVVF). Workshop Sections of DMRCAxis Institute of Technology & Management
  • 32. Technical Specification: Capacity 220KW Voltage 1040V Current 150A Speed 2135 r/min Freq 72.5 Hz Poles 4 Mass 695kg TRAIN INTEGRATED MANAGEMENT SYSTEM The Train Integrated Management System (TIMS) provides a centralized function to monitor the train borne systems and devices. It also provides the operators interface via a Video Display Unit mounted on the operator desk. This display unit shows relevant information to the operator about the status of On board equipment as well as commanded functions. The Train Information Management System interfaces with the following systems located throughout the train, these systems are:  Traction Inverter (CI)  Auxiliary Power Supply (SIV)  Brake Electronic Control Unit (Brake System)  Door Control Units  Air conditioners  AVAS & PA Workshop Sections of DMRCAxis Institute of Technology & Management
  • 33.  Train Radio  ATC System The Train Integrated Management System also monitors Train Line status, switch and circuit breaker positions.  FAULT DETECTION LEVELS Fault detection is classified into five critically levels- Level 1: Critical Fault Faults that require the immediate action/attention of the train operator are classified as critical fault. Level 2: Operating Event An event which is triggered by the train operator. Level 3: Maintenance Event An event that requires the attention of maintenance staff, after the train has completed the scheduled service operation. Level 4: Record A maintenance record that requires the attention of the maintenance staff during scheduled routine maintenance Level 5: Notice Information or reminder to aid the train operator during normal service under defined conditions. Notification and Recording of Events: Fault Criticality Level Level – I Level – II Level – III Level – IV Level – V Pop Up X X Departure X X Workshop Sections of DMRCAxis Institute of Technology & Management
  • 34. Current Fault X X History X X Memory X X X X X  TIMS OPERATION MODES Operator Mode Functions: The TIMS system has the following functions which are accessible to the driver.  System Check Screens - On this screen, TIMS will display on the main window a list of Train faults that have been detected. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 35. Additional information about other systems can be checked by driver by touching the soft keys at the bottom of the screen display. The available soft keys and corresponding train systems are: DOOR The status of Door system is displayed. BRAKES The status of the Pneumatic Brake system is displayed. POWER The status of the High Tension circuit and equipment is displayed. AUX The status of the Auxiliary Power Supply System is displayed. AIR CON The status of the Air Conditioning system is displayed. HISTORY A list of previously record critical faults are displayed. DEPARTURE The departure check screen is displayed. MAIN The LOGOFF screen is displayed. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 36. Maintenance Mode Functions: The TIMS system functions available to the operator are also accessible to Maintenance staff. In addition maintenance staff can also access the following functions.  Data download / upload by TIMS Maintenance Terminal  Data and status check on VDU When the maintenance staff log on to the TIMS system, the Maintenance Menu screen is displayed. From this screen maintenance staff can check or view the status of the TIMS system or equipment sub system. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 37. TIMS Equipment Locations: Car Type Equipment DT M Central Unit X Local Unit X Display Unit X Display Controller X  TIMS EQUIPMENT DESCRIPTION The Train Integrated Management System consists of the following equipment boxes located on the Driving Trailer car and Motor car. Central Unit: The Central Unit carries out the application programs for the overall control and administration of the TIMS system. The Central Unit has two central processor units (CPU1 & CPU2) Both CPU's are operational and in case of one CPU failure the other CPU can continue the data transmission function. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 38. One central unit is provided in every DT car. The Central Unit is comprised of the following components:  Sub Rack  CPU 4 PCB  CIF 4 PCB  DIS2 PCB  DIS 3 PCB  AIO PCB  PSG PCB Local Unit: The Local Unit is provided in each car to interface with various devices and intelligent train subsystems such as Air Conditioning, Propulsion System, Auxiliary Supply System, Brake Electronic Control Unit and Door Control Units. The Local Unit is comprised of the following components:  Sub Rack  CPU 4 PCB  TRC 4 PCB  DIS 2 PCB Workshop Sections of DMRCAxis Institute of Technology & Management
  • 39.  DIS 3 PCB  PSG PCB Display Controller The Display Controller (DC)) is installed in DT car. The Display Controller is comprised of the following:  Line Filter  DC – DC converter  Connector Video Display Unit: The Video Display Unit has two main functions.  To provide the Operator with information regarding the status of the various systems throughout the train.  To enable the Operator to quickly determine the nature of any subsystem failure and perform the required actions to either rectify or isolate the fault. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 40. PA/PIS SYSTEM Circuit diagram The PA and PIS System is powered up by input voltage of DC110V. The system is consisted of AVAU, MOP, AOP, TNI and DIF which are installed in driver cabin PAMP, Loudspeaker, ETU, PAB, PIB which are installed in saloon car. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 41. Location: The PA & PIS system location can be divided by two parts, the driver cabin and passenger saloon area. The PA/PIS system consists of two basic systems 1. Visual System – Passenger Information System 2. Audio System – Automatic Voice announcement System  VISUAL SYSTEM  PASSENGER INFORMATION BOARD (PIB) Location: There are three PIB’s installed in each passenger saloon. All three are powered from the train battery 110V DC supply and continues to operate when traction power is lost. Function: The main function of the PIB’s is to provide information to the passengers. The PIB provides the following information: Workshop Sections of DMRCAxis Institute of Technology & Management
  • 42. 1. Next station is …. - inside train, on the PIB’s 2. This station is … - inside train, on the PIB’s 3. Journey message …..inside train, on the PIB’s 4. Real time information (visual only) - inside train, on the PIB’s (generated by OCC) The Passenger Information Board (PIB) has a display matrix 32 (H) x 160(W) pixels. Both Hindi and English messages can be scrolled on the display simultaneously and in synchronism. It is recommended that for the automatic route announcements Hindi Characters are displayed in yellow and the English characters in green. Emergency announcements may be displayed in red. PIB consists of three main cards: a) Interface Card: Used for communication between two cards within PIB. b) Power Supply Card: It converts 110V DC to 5V DC by using SMPS(Switched Mode Power Supply), now this 5V is send to interface card which further sends it to the third card i.e. Control Card. c) Control Card: It decodes the information given by AVAU (Automatic Voice Announcement Unit) and displays on PIB. Driver enters station AVAU PAMP information is Code in MOP Displayed on PIB Flow diagram  DESTINATION IN FRONT OF TRAIN DISPLAY (DIF) Location: The single DIF is installed in each driver’s cab left window. Function: Workshop Sections of DMRCAxis Institute of Technology & Management
  • 43. It displays train destination. The LED matrix is 48 LED’s high by 96 LED’s wide. The matrix shall be used for two distinct lines, the upper line for Hindi characters, and the lower line for English characters. The display shall check the message to be displayed, independently for the Hindi line, and automatically size the message to make the best fit. The LED’s shall be yellow ultra bright types for sunlight legibility. The LED brightness shall be automatically varied according to ambient light level measured by a light sensor at the front of the display. The displays are powered by the train battery 110V DC supply.  TRAIN NUMBER INDICATOR (TNI) Location: The single TNI is installed in each driver’s cab right window. Function: It is displays a four digit code. First two digits signify destination code and last two digits signify train no. (E.g. 1234 here ‘12’ is the destination code and ‘34’ is train no). The TNI is powered from 110V DC. The LED matrix is 32 LED’s high by 96 LED’s wide. The number shall be four digit displayed with leading zero’s. The numeric characters shall be ‘multiple strike’ for maximum visibility. The LED’s shall be yellow ultra bright types for sunlight legibility. The LED Workshop Sections of DMRCAxis Institute of Technology & Management
  • 44. brightness shall be automatically varied according to ambient light level measured by a light sensor at the front of the display. The display area is 127 mm high by 383 mm wide  Automatic Voice Announcement System (AVAU) It is the heart of PA & PIS System and all functions are controlled by AVAU. Location: It is located in behind of the back wall in driver main console. Function: The system closely integrates the audio and visual (PIS) functions. The AVAU processor deals with the basic audio. Audio System: The main functionality of the audio system is summarized in the following bullet points: Workshop Sections of DMRCAxis Institute of Technology & Management
  • 45.  Public Address – driver (active cab) to passengers (broadcast)  Public Address – rear cab (inactive cab) to passengers (broadcast)  Public Address – OCC (EPA) to passengers (broadcast)  Public Address – Automatic announcement triggered automatically by the PIC, as a result of input from ATO/ATP (including door open chime)  Public Address – Automatic announcement manually triggered by driver on the MOP  Public Address – Automatic Announcement manually triggered from rear cab MOP  Cab to Cab communication (simplex) – Driver to all other cabs (including coupled trains)  Cab to cab communication (simplex) – Any cab to all other cabs (including coupled trains)  Passenger alarm warning tone  Passenger Communication (simplex) – Driver to individual passenger, call set up as a consequence of PAB operation.  Door open/ closing chime Workshop Sections of DMRCAxis Institute of Technology & Management
  • 46. AVAU consists of following cards:  Vehicle Communication Card It is located at the first in upper card row of AVAU. The Vehicle Communications card is the serial communications interface that is used by the AVAU.  Cab Audio Communications Unit CPU Card It is located at the fourth in upper card row of AVAU. This card is the central part of the AVAU system; the processor on this card controls all AVAU functions. It comprises a memory card adapter and a solid- state announcement record/ playback device for digitally stored announcements.  Expanded Serial I/O Card It is located at the 3rd in upper card row of AVAU. The Expanded serial I/O card provides additional serial interfaces using the spare serial interface UART’s of the Vehicle Communications module. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 47.  Audio Control Matrix Card It is located at the 5th from left hand side in upper card row of AVAU. The Audio control matrix is a central part of the AVAU; the card is responsible for switching and routing all of the audio signals.  Front Panel Communications Card It is located at the 2nd from right hand side in upper card row of AVAU. This card contains all of the interface circuits to the AOP & MOP units.  Analogue Train Wire Interface Card It is located the 3rd from right hand side in upper card row of AVAU. This card is the major external interface for signals from/ to the AVAU. The card includes audio line drivers and receivers.  Digital Train Wire Interface Card It is located at the first from right hand side in upper card row of AVAU. This card is the major external interface for digital signals from/ to the AVAU.  Power Supply Interface Module It is located at the 2nd from right hand side in lower card row of AVAU. This module takes the incoming power supply from the train and provides filtering and transient suppression before the power is provided to the main DC-DC converter.  Main Power Supply DC-DC Converter Module It is located at the first from right hand side in lower card row of AVAU. This is a proprietary DC-DC converter. Power supply operates from the train battery supply (nominal 110V DC) and provides a stable 24V DC output. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 48.  Main Power Supply DC-DC Converter Module It is located at the 3rd from right hand side in lower card row of AVAU. This power supply card uses the stable 24V output main supply to create multiple supply rails.  Passenger Information System Control Card (PIC) It is located at the 2nd from left hand side in upper card row of AVAU/PIC Rack. This card is the heart of the PIS system comprising the communication control software for all PIS communications equipment. Its primary function is the storage of a route database complete with references for the audio system solid-state announcements and visual messages for displays. These messages are released in a controlled manner at specific trigger points determined either by the input from ATO/ATP, or through manual command via the MOP  AUDIO SYSTEM The main Components of audio system are as following :  MAIN OPERATING PANEL (MOP) The front panel is a polyester membrane over a steel plate, with apertures in the steel plate for button caps, the loudspeaker and the LCD display .The membrane has a transparent window for the LCD display and the membrane is acoustically transparent, allowing sound to be transmitted from the loud speaker and protecting it from dust and moisture. Areas under the buttons have a transparent ring, allowing the rear illumination to identify the location of each button at night. It gives information about train ID. Command is send from MOP by driver to let the passengers know about the next station which gets displayed on PIB. The MOP panel is connected in parallel with the AOP panel. Location: It is installed on left hand side in the driver cabin. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 49. The panel includes the following functional components: - Keypad – 16 buttons - Mode selection buttons, each with an associated with LED - Backlighting for all the MOP buttons - LCD graphics display – 64 X 192 pixels with LED back-light - Loudspeaker - 24V DC Power supply - Red Button (PEA i.e. Passenger emergency alarm) - Yellow Button(PA i.e. announcement in train) - Blue Button(CC i.e. Cab to Cab communication) MOP - Keypad Assembly Functions: a) Initialisation of Manual broadcasting such as special messages, emergency messages, station name by train operator. b) The train operator can talk to desired passenger who activated passenger Alarm System. c) LCD Display for major function of operation. d) For PAB indication, MOP Display shows the actual car number with PAB no. e) Initialisation of Cab-to-Cab intercom. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 50.  AOP (Auxiliary Operating Panel) The AOP has a subset of the functions provided by the MOP. The AOP comprises the mode selection controls for PA and Cab to Cab.There is no keypad or LCD display. Passenger emergency communication shall be controlled from the MOP only. A loudspeaker is included on the AOP and this produces the same audio that is produced by the MOP. It is connected with MOP in parallel. Location: It is installed on right hand side in the driver cabin. AOP  EMERGENCY TALK BACK UNIT (ETU) & PASSENGER ALARM BUTTON (PAB) ETU PAB Workshop Sections of DMRCAxis Institute of Technology & Management
  • 51. In case of emergency if a passenger wants to talk to the driver he can do so with the help of ETU i.e. EMERGENCY TALK BACK UNIT and PAB i.e. PASSENGER ALARM BUTTON. The PAB is installed at each passenger exterior doorway. There are four PAB’s in each vehicle, associated to doors L1 L2 R1 and R2. ETU is installed at each door position, with the microphone/loudspeaker positioned approx 1.5m from the vehicle floor. We have four ETU’s in each car. It is provided as an interface between the passenger and the driver. The Passenger can talk to the driver through the ETU. As soon as the passenger presses PAB, ETU detects that PAB has been operated, and will identify this condition to the PAMP. The PAMP then send signal to AVAU which further informs the driver by sending information at MOP. Now driver is ready to talk to the passenger. The position of that particular ETU is also displayed on MOP. The large red circular button is mechanically latched and is reset by inserting and turning a square Carriage Key in a clockwise direction. The button is red in colour, having a central part with the square key-hole; this central part is silver in colour. ETU is installed at each door position, with the microphone/ loudspeaker positioned approx. 1.5m from the vehicle floor. The ETU shall identify when a PAB has been activated. Flow diagram: PAB ETU PAMP AVAU MOP  Loudspeaker & 100V line transformer The loudspeaker can be driven with 4Watts of power, provided by the PAMP over the 100V line distribution system. Location: It is installed with 6 sets in each saloon. Workshop Sections of DMRCAxis Institute of Technology & Management
  • 52.  PA Amplifier (PAMP) The PAMP contains the audio power amplifier to drive the loudspeakers at 100V line level, and monitors/ controls the four ETU’s in the same vehicle. The interfaces to the Train bus and saloon data- bus (RS485) are through 3.5mm versions. It also controls the Vehicle data bus in that car, providing PIB’s with data – received from the Train Data bus. PAMP Location: PAMP is installed in the “Gangway Cubicle” in passenger saloon each. Functions: The PAMP contains the audio power amplifier to drive the loudspeakers at 100V line level, and monitors/ controls the four ETU’s in the same vehicle. The PAMP is to be configured with the Car ID (sequence number from the A end cab), as this is used as a WELNET system address. The PA power amplifier incorporates the Whiteley SOALAS (Sound Operated Automatic Level Adjusting System) whereby the loudspeaker system is used as a microphone when PA is not enabled, allowing the gain to be set at the sampled ambient level in the 3 second period before the PA announcement commences.  Switched Mode Power Supply (SMPS) Workshop Sections of DMRCAxis Institute of Technology & Management
  • 53. Like a linear power supply, the switched mode power supply too converts the available unregulated ac or dc input voltage to a regulated dc output voltage. However in case of SMPS with input supply drawn from the ac mains, the input voltage is first rectified and filtered using a capacitor at the rectifier output. The unregulated dc voltage across the capacitor is then fed to a high frequency dc-to-dc converter. Most of the dc-to-dc converters used in SMPS circuits have an intermediate high frequency ac conversion stage to facilitate the use of a high frequency transformer for voltage scaling and isolation. In contrast, in linear power supplies with input voltage drawn from ac mains, the mains voltage is first stepped down (and isolated) to the desired magnitude using a mains frequency transformer, followed by rectification and filtering. The high frequency transformer used in a SMPS circuit is much smaller in size and weight compared to the low frequency transformer of the linear power supply circuit. The ‘Switched Mode Power Supply’ owes its name to the dc-to-dc switching converter for conversion from unregulated dc input voltage to regulated dc output voltage. The switch employed is turned ‘ON’ and ‘OFF’ (referred as switching) at a high frequency. During ‘ON’ mode the switch is in saturation mode with negligible voltage drop across the collector and emitter terminals of the switch where as in ‘OFF’ mode the switch is in cut-off mode with negligible current through the collector and emitter terminals. On the contrary the voltage-regulating switch, in a linear regulator circuit, always remains in the active region. Workshop Sections of DMRCAxis Institute of Technology & Management