2. BETTER ACP, BETTER LIFE
Index
Introduction to LITONG OSTER
Why use LITONG OSTER
Series & Technical Details
Products Showcase
LITONG OSTER Applications
OSTER Standard Color Chart
General Information
Contact Us
3
4
6
8
11
14
18
24
2
3. Hong Kong Litong Int’l
Holdings(Group)Ltd. Is a large-scale
diversified enterprise by integrating
industry, trading, investment, import
and export. It invested to set up 16
enterprises in mainland of China such
as Shanghai, Guangdong, Jiangsu,
SHANDONG, Henan, and Heilongjiang,
etc., it also set up two joint venture
enterprises abroad and five overseas
agencies in Moscow, Vancouver,
Valencia, Dubai, and Bombay. The
company developed a series of
products comprising the color-coated
aluminum composite panels,
aluminum ceilings; specialized color-
coating production line, aluminum
composite panel production line and
manufacturing machines for venetian
blinds; pains for hardware and civil
building application, wide spectrum of
resins and chemical agents for pre-
treatment; wooden and aluminum
venetian blinds.
All the companies invested by Litong
Group have been entitled with
ISO9001 Quality System certificate,
and part of which have passed
ISO14000 Environment System
Certificate. Based on its advanced
technologies, good qualities, excellent
techniques and sincere services, so far
Litong has built a good cooperation
relationship with over 200 enterprises
in China and nearly 100 purchasers
from more than 60 countries and
regions overseas.
Foshan Shunde Litong Oster
Building Material Co., Ltd, a
modern enterprise specialized in
producing and marketing updated
materials for advance construction
and decoration, is invested by
Hong Kong Litong Int’l Holdings
(Group) Ltd. With a dominative
share holding. Our company is
dedicated to the development of
advance construction and
decoration sector in China, base on
the management philosophy –
“Science and technology create the
future. Talents are the key factor”.
Our company has adopted most
advanced ACP production lines.
Supposed by sophisticate
workforce, our company created
top quality “Oster” brand ACP with
the most competitive price. Our
products are recommended by
China Construction Materials
Association as most preferential
and are rewarded as “Excellent
Environmental Protection in China”
by China Light Industry Centre for
Quality Super Vision due to the
excellent quality.
Our annual capacity is over
360,000 ㎡, half of which have
been exported to overseas.
3
4. 10 Reasons to Use
OSTER
2 Dimensionally Stable. Minimal expansion and contraction rates.
3 High quality, fully certified product.
4 High UV Resistance.
5 15 year product guarantee.
6 Incredibly flat, smooth surface.
7 Simple to cut, router, fold and bend!
8 One of the largest color ranges on the market, available globally.
9 Suitable for digital printing, screen printing, vinyl application and painting.
10 The most competitively priced, high quality ACP on the market.
1 Incredibly rigid with an impressive weight advantage.
Clients Around the World
4
5. Certificates:
1 LITONG OSTER ACP approved by authoritative organizations, like SGS,
UL, EXOVA, etc.
2 Fir- resistance ACP coincidence to the fire resistance requirements of
Singapore, English, Australia, etc.
3 LITONG OSTER operates a recycling policy that make sure clients can
select recycle raw material or new raw material freely, which based on
the clients’ local policy.
5
7. Test Items and Results
Test Results[3mm]
Test Items Standard Value Test Results
Coating thickness,μ m ≥16 20
Gloss deviation Extreme value error≤5 3
Pencilhardness ≥HB 3HB
Coating flexibiligy,T ≤3 1
Cohesive force,grad Grid drawing method grade 1 Grade 1
Comoact resitance,50kg.cm No peeling,no cracks No peeling, no cracks
Bend strength,Mpa ≥60 83.4
Bend flexibolilty modulus, Mpa ≥1.5x104
2.1x104
Penetrating resistance,KN ≥5.0 6.5
Cut strength,Mpa ≥20.0 23.2
180℃ Peel strength,N/mm ≥5.0 5.0
Temperature difference resistance No change No change
Heat expansion coefficient,℃-1
≤4.00x10-5
3.20x10-5
Heat deformation temperature,℃ ≥105 119.6
Acetonic acid resistance(500h) No less than grade 2 No change
Boiled water resistance No change No change
Chemical
Resistance
Acid resistance No change No change
Alkali resistance No change No change
Oil resistance No change No change
Solvent resistance No bottom appearing No bottom appearing
Washing resistance ≥10000 times 11500
Artificial
aging
resistance,50
0h
Chromatic aberration
CIELAB ≤3.0 0.42
Pulverization grade 0 Non-pulverization
Light loss grade No less than grade 2 No less than grade 2
Test Results[4mm]
Test Items Standard Value Test Results
Coating thickness,μ m ≥25 28
Gloss deviation Extreme value error≤5 3
Pencilhardness ≥HB 3HB
Coating flexibiligy,T ≤2 0
Cohesive force,grad Grid drawing method grade 1 Grade 1
Comoact resitance,50kg.cm No peeling,no cracks No peeling, no cracks
Comoact resistance,L/μ m ≥5.0 8
Bend strength,Mpa ≥100 135.7
Bend flexibolilty modulus, Mpa ≥2.0x104
2.9x104
Penetrating resistance,KN ≥9.0 10.8
Cut strength,Mpa ≥28.0 32.2
180℃ Peel strength,N/mm ≥7.0 7.0
Temperature difference resistance No change No change
Heat expansion coefficient,℃-1
≤4.00x10-5
3.00x10-5
Heat deformation temperature,℃ ≥105 121.6
Acetonic acid resistance(500h) No less than grade 2 No change
Boiled water resistance No change No change
Chemical
Resistance
Acid resistance No change No change
Alkali resistance No change No change
Oil resistance No change No change
Solvent resistance No bottom appearing No bottom appearing
Washing resistance ≥10000 times 13000
Artificial
aging
resistance,50
0h
Chromatic aberration
CIELAB ≤3.0 0.52
Pulverization grade 0 Non-pulverization
Light loss grade No less than grade 2 No less than grade 2
7
13. A selection of the many applications for OSTER ACP:
• Shop Fitting and Design
• Exhibition Stand Designs
• Wayfinding Solutions
• Partitioning, Wall Linings and Suspended Ceilings
• Curtain wall decoration for buildings, such as airports, hospitals
and research centers
• Curtain wallboards for outside walls of normal buildings
• Renovations of old buildings and movable houses
• Reformation and decoration for indoor walls, ceilings,
bathrooms, kitchens and balconies
• Facades
• Billboards and notice boards
• Wallboards and ceilings for tunnels
• Materials for industrial application, car and ship bodies
• Gas piping, cables, building materials, etc (this product fills
a gap in the domestic construction materials field, with
performance indexes superior to panels manufactured overseas)
13
20. OSTER ACP
Processing techniques
4 Flap the edges
7.A.3 Aluminum profiles of the
stent structure
1 Sawing and cutting with
trapezoidal / flat tooth
blade
2 Drilling
3 Slot with grooving
machine
5 On a fixed angle code6 Insert rivets
7.A.1 Aluminum embedded parts
of the installation structure
7.A.2 Embedded parts of the
aluminum profiles method
7.B.1 Embedded parts of the iron
structure of the installation
7.B.2 Iron embedded parts of and
link the link with the profile method
7.B.3 Iron profiles of the
stent structure 20
21. OSTER ACP
Processing techniques
8 Install aluminum composite
panel
9 Tear the protective film
Filling Gaps
1 Paste tapes , avoiding panel
surface be glued by sealant
2 Fill the bubble in the gaps 3 Filled gaps with sealant
4 Sealant gapping 14 Sealant gapping 25 Tear the tape
6 Tear another tape 7 Finished
21
22. Storage,
Handling and Colors
Storage
Instructions:
OSTER panels should be stored in a clean, dry
area. Before use, ensure panels are at a
minimum temperature of 15°C. It is important
that when sheets are not in use they are stored
correctly. A protective layer between sheets is
advised to prevent damage occurring and
stacking on a level, horizontal surface is
recommended.
Protective
Equipment:
In all cases you should follow the safety
practices of your workplace. However, we
advise you to handle any sheet with gloves, and
strictly follow the instructions of your machining
equipment manufacturer.
Protective Films:
The clear film on both sides of
the panel is a protective measure whilst the
panel is being processed, transported and
installed. This protective film should remain
on the panel for the duration of the
installation only. You must remove this film
once the panel has been fixed and set in
place. Due to the nature of the finishing
process the paint has a directional quality.
Care must be taken when using multiple
sheets to ensure that the panel is installed in
the same direction. This can be done by
following the direction of the printed
arrows on the protective film.
Handling
OSTER Sheets:
OSTER sheets should be handled with care.
If large sheet sizes must be handled it is
recommended that a suitable number of
staff should assist in the process. When
removing panels from a pallet/stack never
drag the panel, always lift clear above the
remaining panels on the stack. This will
require two or more operatives.
Cleaning:
Regular cleaning may be required depending
on where the panel has been used.
• A moderate amount of pressure is all
that’s needed in order to clean the surface.
• It is important that you avoid
any alkaline, acidic and abrasive cleaning
products as this can have an adverse effect
on the panels PE coating.
• When the panel has been cleaned you
should rinse off with clean water and rub
down with an absorbent cloth/leather to
remove any residue left behind.
Colors:
As OSTER panel is coated in the factory, we
have the flexibility to provide a full range of
non-standard colors to match almost any
RAL and Pantone color.
Special orders will be subject to a minimum
order quantity, and a marginally longer lead
time than standard product.
If you have a requirement for a specific
color match, please contact us to discuss
your needs. 22