Russian Call Girls in Jaipur Riya WhatsApp ❤8445551418 VIP Call Girls Jaipur
Intramedullary nailing vs volar plating for distal radius fractures
1. Intramedullary Nailing for
Distal Radius Fractures: A
Systematic Review
RW Jordan, A Saithna
Southport and Ormskirk Hospitals
NHS Trust, Merseyside, UK
2. Introduction
Distal radius fractures are common injuries
No clear consensus regarding optimal
management of unstable fractures
Open reduction and internal fixation with volar
plates had become increasingly popular
Recent studies suggested K-wires as effective as
plate fixation
Intramedullary nails are an alternative
Reduced risk of tendon injury
Reduced risk of intra-articular screw penetration
This article systematically reviews the biomechanics,
outcomes and complications of intramedullary nails
3. Methods
Systematic review of the literature using the
online databases Medline and EMBASE
performed on the 1st of August 2014
All studies assessed adults who had
sustained any type of distal radius fracture
treated with an IM nail
Data regarding clinical outcomes and
complications were extracted
These studies were appraised independently
by both authors using a validated quality
assessment scale
4. Results
16 studies were included for review
The biomechanical studies concluded that
intramedullary nails had at least comparable
strength to locking plates
The clinical studies reported that IM nailing was
associated with comparable ROM, functional
outcome and grip strength to alternative fixation
techniques.
However, the mean complication rate was 17.6%
(range 0 to 50%) with the most common
complication being neurapraxia of the superficial
radial nerve in 9.5%.
5. Conclusion
IM nailing can give comparable clinical results to
current treatment modalities in extra-articular
and simple intra-articular distal radius fractures.
However the evidence is insufficient to
determine whether IM nailing has any clinically
important advantage over well-established
alternatives.
The complication rate reported is higher than
that in contemporary studies for volar plating
Further adequately powered RCTs comparing
the technique to volar plates and K-wire fixation
are required