Understanding of
REDI




 Kamal Raj Krishnan
AGENDA
 INTRODUCTION To REDI
 FORM FACTORS
 INTRODUCTION - Air Cool Design
    Design Considerations
    Important Rules to remember
 INTRODUCTION – Conduction Cool Design
    Design Considerations
    Important Rules to remember
 Any Questions..
INTRODUCTION - REDI
 REDI is the Mechanical specification of ruggedized electronics system
  and it is defined by VITA48 Standard.
 REDI – Ruggedized Enhanced Design Implementation
 This REDI standard defines the mechanical design Implementation for
  Plug in Units in VPX system Environment
 REDI defines Various Thermal Management Mechanical Design
  implementations namely the Air Cooling, Conduction Cooling, Liquid
  Cooling based on classified standards VITA 48.1, 48.2, 48.3..
 REDI defines two types of Plug In Units namely TYPE1 and TYPE2
 TYPE1 Plug-In Units are compatible for handling in 2 Level
  Maintenance Environments where TYPE2 Plug-In Units requires
  required precaution in handling
 Primary Difference between TYPE1 & TYPE2 units is the presence of
  External covers
 REDI supports the 0.8”, 0.85” and 1.0” Pitch Plugging on Back Plane
REDI – FORM FACTORS
 REDI recommends two Board Sizes as 3U [100mm X 160mm] and 6U
  [233.35mm X 160mm] for circuit Boards & plug-in units with AIR or
  Conduction cool mechanism
 The base Mechanical specifications of PCB & Plug-In units are defined
  by VITA46
 The Allowable Standoff Height for PMC/XMC is 10mm where 0.8” &
  0.85” plug-in unit scheme. It is 12mm where 1.0” pitch Plug-in unit
  scheme. In this Sufficient Package area to be planned for protective
  cover for TYPE1 Card
REDI – Introduction to Air Cool Mechanism

 REDI Air cool mechanism defined by VITA48.1 standard specification
 For Conductive elements such as Frame Covers - Need not to connect to
PCB electrically except connecting to Safety Ground
REDI –Air Cool Mechanism
 This STD VITA48.1 defines Minimum PCB thickness as 0.06”
 It defines the mechanical interface specifications of components
  namely Main PCB, Main Frame, PMC/XMC, PMC/XMC Cover, and
  Secondary cover as it is indicated in the Image
 For main board Connector Protection, Primary Cover, PMC/XMC Cover
  and Secondary cover can be extended up to connector Edge
REDI –Air Cool Mechanism
 Cover Thickness & extension specification is indicated in following
  table
NF – Not Feasible, FwR-Feasible with Risk, F-Feasible
REDI –Air Cool Mechanism
 3U Air Cooled Plug-in Unit – Form factors
REDI –Air Cool Mechanism
 Primary side Cover provides following
     Accepts PMC/XMC and Cover for PMC/XMC
     EMC Compatibility & ESD Protection
     Maintains the managed Air flow paths in air-cooled applications
     Can contain Insertion / Extraction Features
 Secondary Side Cover provides following
     EMC Compatibility & ESD Protection
     Provides protection for secondary side components
     Maintains the managed Air flow paths in air-cooled applications
REDI –Air Cool Mechanism
 Secondary Side Cooling should be carefully evaluated particularly for
  0.8” & 0.85” because of limited Gap between Secondary cover to PCB.
  This is likely to be High Pressure Flow path where cooling air
  requirements are high
 Component Layout can be critical to proper plug-in unit Cooling. The
  Layout should consider the flow direction, shadowing effect, air
  preheating, re-circulation etc..
 The Direction of Airflow should be as shown in image
REDI –Air Cool Mechanism – Important Rules to Remember
 Rule 7-4: Thickness of Plu-in unit that interface with sub Rack’s Card
  Guide shall be 1.6mm +-0.2mm. But if Thicker PCB is recommended,
  then the distance from Primary side of PCB to Outside of Secondary
  cover is to be maintained as per Pitch of Plug-in units
 Rule 7-5: Covers shall be electrically connected to safety ground with
  resistance not to exceed 100mohm
 Rule 7-9: Maximum Plug-in Width is defined by following Table




 Rule 7-11, 7-12: Primary & Secondary Side Cover is mandatory for
  TYPE1 and it is not required for TYPE2 implementations
 Rule 13-1: In Order to achieve 2 Level maintenance, Type1 Plu-in units
  shall comply with ESD requirements of VITA 47
REDI –Conduction Cool Mechanism
 REDI conduction Cool mechanism is defined by VITA 48.1
 It defines the detailed mechanical implementation for conduction cool
  mechanism for PCB/Plug-In Units which is defined by VITA 46
 In Conduction Cooled System, there are two important components
  namely Frame and Cover. Frame used to transfer the heat from
  PCB/components to Sub rack and Cover is used to cover the Both side
  of Plug-In units with support of ESD suppression
 Cover Plate differentiates the TYPE1 & TYPE2 Cards
 The PCB thickness can be variable from 0.06” [1.5mm] to
  0.12”[3.048mm] and Even Thicker PCB also can be accommodated
  based on considering the Guide Rail Thickness and so PCB is limited on
  following
     For Primary Side Retainer design – 0.137”[3.48mm]MAX
     For secondary side Retainer Design – 0.112”[2.85mm]MAX
REDI –Conduction Cool Mechanism
 REDI conduction Cool mechanism defines 2 way implementation the Design based
  on retainer placement.
     Primary Side Retainer
     Secondary side Retainer
REDI –Conduction Cool Mechanism
 REDI conduction Cool mechanism Supports Connector Side Protections
  as it is indicated by image
REDI –Conduction Cool Mechanism
 REDI conduction Cool mechanism – Primary Side Retainer
REDI –Conduction Cool Mechanism
 REDI conduction Cool mechanism – Secondary Side Retainer
REDI –Conduction Cool Mechanism
 REDI conduction Cool mechanism – Retainer Position
     Plug-In Unit along with Retainer plugged on Guide Rail of Chassis with Gap of 13.34mm
     In Retainer Relaxed State, thermal interface side should not have any gap with Rack Wall and
      Retainer side will have 0.76mm gap. Total Plug-in unit Thickness on Guide Rail is 12.57mm
     In Retainer tightened state, Total Plug-in Unit Thickness will be 13.3mm
     Card Guide Depth is 9.19mm to 10.41mm
REDI –Conduction Cool Mechanism – Guidance on Cooling
 Component Layout can be critical to proper plug-in unit cooling. The
  layout should consider the how each component cooling, length and
  cross sectional area of heat transfer paths etc..
 The conduction contact area for heat transfer from plug-in unit is
  dependant on several factors, including the depth of card, the presence
  of air cooled card guide projection.
REDI –Conduction Cool Mechanism – Important Rules to
                     Remember
 Rule 6-1: For Type1 Implementations, Both Primary & Secondary side
  covers shall be required
 Rule 6-12: Covers shall be electrically connected to safety ground with
  resistance not to exceed 100mohm
 Rule 6-11: Maximum Plug-in Width is defined by following Table




 Rule 7-11, 7-12: Primary & Secondary Side Cover is mandatory for
  TYPE1 and it is not required for TYPE2 implementations
 Rule 13-1: In Order to achieve 2 Level maintenance, Type1 Plu-in units
  shall comply with ESD requirements of VITA 47
REDI - VPX
 Any Questions for Discussion..........

More Related Content

What's hot

OODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface Solutions
OODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface SolutionsOODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface Solutions
OODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface SolutionsODSA Workgroup
 
Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...
Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...
Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...Leah Wilkinson
 
Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...
Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...
Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...Yole Developpement
 
Optical Network Unit - ONU
Optical Network Unit - ONUOptical Network Unit - ONU
Optical Network Unit - ONUAzam Udayar
 
Status of Panel Level Packaging 2018 Report by Yole Developpement
Status of Panel Level Packaging 2018 Report by Yole Developpement Status of Panel Level Packaging 2018 Report by Yole Developpement
Status of Panel Level Packaging 2018 Report by Yole Developpement Yole Developpement
 
Study of 5G FAPI Specification
Study of 5G FAPI SpecificationStudy of 5G FAPI Specification
Study of 5G FAPI SpecificationImamNurBaniYusuf
 
MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...
MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...
MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...MIPI Alliance
 
High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...
High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...
High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...Ran Ding
 
Premarket Notification The 510(k) Process
Premarket Notification The 510(k) ProcessPremarket Notification The 510(k) Process
Premarket Notification The 510(k) ProcessMichael Swit
 
GaN RF Market: Applications, Players, Technology and Substrates 2020
GaN RF Market: Applications, Players, Technology and Substrates 2020GaN RF Market: Applications, Players, Technology and Substrates 2020
GaN RF Market: Applications, Players, Technology and Substrates 2020Yole Developpement
 
Japanse Medical Device Submission Requirements
Japanse Medical Device Submission RequirementsJapanse Medical Device Submission Requirements
Japanse Medical Device Submission RequirementsKuldeep Badoniya
 
Gpon Fundamentals
Gpon FundamentalsGpon Fundamentals
Gpon Fundamentalsmansoor_gr8
 
Scaling Beyond 100G With 400G and 800G
Scaling Beyond 100G With 400G and 800GScaling Beyond 100G With 400G and 800G
Scaling Beyond 100G With 400G and 800GAPNIC
 
Raspberry Pi Technology
Raspberry Pi TechnologyRaspberry Pi Technology
Raspberry Pi TechnologyRavi Basil
 
High-end Performance Packaging 2020
High-end Performance Packaging 2020High-end Performance Packaging 2020
High-end Performance Packaging 2020Yole Developpement
 
Qorvo QPF4006 39GHz GaN MMIC Front End Module
Qorvo QPF4006 39GHz GaN MMIC Front End ModuleQorvo QPF4006 39GHz GaN MMIC Front End Module
Qorvo QPF4006 39GHz GaN MMIC Front End Modulesystem_plus
 
Cambium networks prensent
Cambium networks prensentCambium networks prensent
Cambium networks prensentjmmypham
 

What's hot (20)

OODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface Solutions
OODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface SolutionsOODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface Solutions
OODSA - BoW: Basic, Fast, Turbo Die-to Die Open Interface Solutions
 
Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...
Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...
Co-Packaged Optics: The OIF’s Work to Standardize Higher Integration Levels f...
 
Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...
Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...
Fan-Out Packaging: Technologies and Market Trends 2019 report by Yole Dévelop...
 
Optical Network Unit - ONU
Optical Network Unit - ONUOptical Network Unit - ONU
Optical Network Unit - ONU
 
Status of Panel Level Packaging 2018 Report by Yole Developpement
Status of Panel Level Packaging 2018 Report by Yole Developpement Status of Panel Level Packaging 2018 Report by Yole Developpement
Status of Panel Level Packaging 2018 Report by Yole Developpement
 
400G/800G High Speed Networking product guide
400G/800G High Speed Networking product guide400G/800G High Speed Networking product guide
400G/800G High Speed Networking product guide
 
Study of 5G FAPI Specification
Study of 5G FAPI SpecificationStudy of 5G FAPI Specification
Study of 5G FAPI Specification
 
MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...
MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...
MIPI DevCon 2021: MIPI I3C Application and Validation Models for IoT Sensor N...
 
High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...
High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...
High-Speed Optical Modulators and Data Communication Systems in Silicon Photo...
 
Premarket Notification The 510(k) Process
Premarket Notification The 510(k) ProcessPremarket Notification The 510(k) Process
Premarket Notification The 510(k) Process
 
GaN RF Market: Applications, Players, Technology and Substrates 2020
GaN RF Market: Applications, Players, Technology and Substrates 2020GaN RF Market: Applications, Players, Technology and Substrates 2020
GaN RF Market: Applications, Players, Technology and Substrates 2020
 
Japanse Medical Device Submission Requirements
Japanse Medical Device Submission RequirementsJapanse Medical Device Submission Requirements
Japanse Medical Device Submission Requirements
 
Gpon Fundamentals
Gpon FundamentalsGpon Fundamentals
Gpon Fundamentals
 
1 4 фізичний рівень
1 4 фізичний рівень1 4 фізичний рівень
1 4 фізичний рівень
 
Scaling Beyond 100G With 400G and 800G
Scaling Beyond 100G With 400G and 800GScaling Beyond 100G With 400G and 800G
Scaling Beyond 100G With 400G and 800G
 
Raspberry Pi Technology
Raspberry Pi TechnologyRaspberry Pi Technology
Raspberry Pi Technology
 
High-end Performance Packaging 2020
High-end Performance Packaging 2020High-end Performance Packaging 2020
High-end Performance Packaging 2020
 
Qorvo QPF4006 39GHz GaN MMIC Front End Module
Qorvo QPF4006 39GHz GaN MMIC Front End ModuleQorvo QPF4006 39GHz GaN MMIC Front End Module
Qorvo QPF4006 39GHz GaN MMIC Front End Module
 
CAN- controlled area network
CAN- controlled area networkCAN- controlled area network
CAN- controlled area network
 
Cambium networks prensent
Cambium networks prensentCambium networks prensent
Cambium networks prensent
 

Similar to Understanding The Vpx Redi

5 Things to Know About Conduction Cooling
5 Things to Know About Conduction Cooling5 Things to Know About Conduction Cooling
5 Things to Know About Conduction CoolingAngela Hauber
 
5 Things to Know About Conduction Cooling (CCA)
5 Things to Know About Conduction Cooling (CCA)5 Things to Know About Conduction Cooling (CCA)
5 Things to Know About Conduction Cooling (CCA)MEN Micro
 
5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)MEN Micro
 
5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)MEN Mikro Elektronik GmbH
 
Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers Raptor Power Systems
 
10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management  10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management Kamal Karimanal
 
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)IJERD Editor
 
WP-59 The Different Types of Air Conditioning Equipment for IT Environments
WP-59 The Different Types of Air Conditioning Equipment for IT EnvironmentsWP-59 The Different Types of Air Conditioning Equipment for IT Environments
WP-59 The Different Types of Air Conditioning Equipment for IT Environmentszain kirmani
 
PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...
PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...
PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...Ingeteam Wind Energy
 
IJSRED-V2I3P92
IJSRED-V2I3P92IJSRED-V2I3P92
IJSRED-V2I3P92IJSRED
 
IJSRED-V2I3P92
IJSRED-V2I3P92IJSRED-V2I3P92
IJSRED-V2I3P92IJSRED
 
48 tc 04-16-03pd paquete carrier
48 tc 04-16-03pd paquete carrier48 tc 04-16-03pd paquete carrier
48 tc 04-16-03pd paquete carrierRios Luis
 
Catalog Mitsubishi Inverter FR D700 Global-Beeteco.com
Catalog Mitsubishi Inverter FR D700 Global-Beeteco.comCatalog Mitsubishi Inverter FR D700 Global-Beeteco.com
Catalog Mitsubishi Inverter FR D700 Global-Beeteco.comBeeteco
 
Cfd thermal analysis on laptop cooling system using loop heat pipe technology
Cfd thermal analysis on laptop cooling system using loop heat pipe technologyCfd thermal analysis on laptop cooling system using loop heat pipe technology
Cfd thermal analysis on laptop cooling system using loop heat pipe technologyeSAT Publishing House
 
Standard boiler 500 mwerection manual (boiler auxiliaries)
Standard boiler 500 mwerection manual (boiler auxiliaries)Standard boiler 500 mwerection manual (boiler auxiliaries)
Standard boiler 500 mwerection manual (boiler auxiliaries)Ashutosh Sachan
 
DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...
DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...
DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...IRJET Journal
 
General Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space ApplicationsGeneral Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space ApplicationsBelilove Company-Engineers
 
Industrial Housings Paper and Presentation
Industrial Housings Paper and PresentationIndustrial Housings Paper and Presentation
Industrial Housings Paper and PresentationMike Nager
 

Similar to Understanding The Vpx Redi (20)

5 Things to Know About Conduction Cooling
5 Things to Know About Conduction Cooling5 Things to Know About Conduction Cooling
5 Things to Know About Conduction Cooling
 
5 Things to Know About Conduction Cooling (CCA)
5 Things to Know About Conduction Cooling (CCA)5 Things to Know About Conduction Cooling (CCA)
5 Things to Know About Conduction Cooling (CCA)
 
5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)
 
5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)5 Things to Know about Conduction Cooling (CCA)
5 Things to Know about Conduction Cooling (CCA)
 
Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers
 
RLKN.pdf
RLKN.pdfRLKN.pdf
RLKN.pdf
 
10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management  10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management
 
Military and aerospace pcb assembly
Military and aerospace pcb assemblyMilitary and aerospace pcb assembly
Military and aerospace pcb assembly
 
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)
 
WP-59 The Different Types of Air Conditioning Equipment for IT Environments
WP-59 The Different Types of Air Conditioning Equipment for IT EnvironmentsWP-59 The Different Types of Air Conditioning Equipment for IT Environments
WP-59 The Different Types of Air Conditioning Equipment for IT Environments
 
PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...
PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...
PES Wind Magazine - New-generation DFIG power converters for 6-8 MW wind turb...
 
IJSRED-V2I3P92
IJSRED-V2I3P92IJSRED-V2I3P92
IJSRED-V2I3P92
 
IJSRED-V2I3P92
IJSRED-V2I3P92IJSRED-V2I3P92
IJSRED-V2I3P92
 
48 tc 04-16-03pd paquete carrier
48 tc 04-16-03pd paquete carrier48 tc 04-16-03pd paquete carrier
48 tc 04-16-03pd paquete carrier
 
Catalog Mitsubishi Inverter FR D700 Global-Beeteco.com
Catalog Mitsubishi Inverter FR D700 Global-Beeteco.comCatalog Mitsubishi Inverter FR D700 Global-Beeteco.com
Catalog Mitsubishi Inverter FR D700 Global-Beeteco.com
 
Cfd thermal analysis on laptop cooling system using loop heat pipe technology
Cfd thermal analysis on laptop cooling system using loop heat pipe technologyCfd thermal analysis on laptop cooling system using loop heat pipe technology
Cfd thermal analysis on laptop cooling system using loop heat pipe technology
 
Standard boiler 500 mwerection manual (boiler auxiliaries)
Standard boiler 500 mwerection manual (boiler auxiliaries)Standard boiler 500 mwerection manual (boiler auxiliaries)
Standard boiler 500 mwerection manual (boiler auxiliaries)
 
DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...
DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...
DESIGN AND FABRICATION OF AN EFFICIENT COLD CONTAINER FOR MEDICINE WHICH CAN ...
 
General Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space ApplicationsGeneral Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space Applications
 
Industrial Housings Paper and Presentation
Industrial Housings Paper and PresentationIndustrial Housings Paper and Presentation
Industrial Housings Paper and Presentation
 

Understanding The Vpx Redi

  • 2. AGENDA  INTRODUCTION To REDI  FORM FACTORS  INTRODUCTION - Air Cool Design  Design Considerations  Important Rules to remember  INTRODUCTION – Conduction Cool Design  Design Considerations  Important Rules to remember  Any Questions..
  • 3. INTRODUCTION - REDI  REDI is the Mechanical specification of ruggedized electronics system and it is defined by VITA48 Standard.  REDI – Ruggedized Enhanced Design Implementation  This REDI standard defines the mechanical design Implementation for Plug in Units in VPX system Environment  REDI defines Various Thermal Management Mechanical Design implementations namely the Air Cooling, Conduction Cooling, Liquid Cooling based on classified standards VITA 48.1, 48.2, 48.3..  REDI defines two types of Plug In Units namely TYPE1 and TYPE2  TYPE1 Plug-In Units are compatible for handling in 2 Level Maintenance Environments where TYPE2 Plug-In Units requires required precaution in handling  Primary Difference between TYPE1 & TYPE2 units is the presence of External covers  REDI supports the 0.8”, 0.85” and 1.0” Pitch Plugging on Back Plane
  • 4. REDI – FORM FACTORS  REDI recommends two Board Sizes as 3U [100mm X 160mm] and 6U [233.35mm X 160mm] for circuit Boards & plug-in units with AIR or Conduction cool mechanism  The base Mechanical specifications of PCB & Plug-In units are defined by VITA46  The Allowable Standoff Height for PMC/XMC is 10mm where 0.8” & 0.85” plug-in unit scheme. It is 12mm where 1.0” pitch Plug-in unit scheme. In this Sufficient Package area to be planned for protective cover for TYPE1 Card
  • 5. REDI – Introduction to Air Cool Mechanism  REDI Air cool mechanism defined by VITA48.1 standard specification  For Conductive elements such as Frame Covers - Need not to connect to PCB electrically except connecting to Safety Ground
  • 6. REDI –Air Cool Mechanism  This STD VITA48.1 defines Minimum PCB thickness as 0.06”  It defines the mechanical interface specifications of components namely Main PCB, Main Frame, PMC/XMC, PMC/XMC Cover, and Secondary cover as it is indicated in the Image  For main board Connector Protection, Primary Cover, PMC/XMC Cover and Secondary cover can be extended up to connector Edge
  • 7. REDI –Air Cool Mechanism  Cover Thickness & extension specification is indicated in following table NF – Not Feasible, FwR-Feasible with Risk, F-Feasible
  • 8. REDI –Air Cool Mechanism  3U Air Cooled Plug-in Unit – Form factors
  • 9. REDI –Air Cool Mechanism  Primary side Cover provides following  Accepts PMC/XMC and Cover for PMC/XMC  EMC Compatibility & ESD Protection  Maintains the managed Air flow paths in air-cooled applications  Can contain Insertion / Extraction Features  Secondary Side Cover provides following  EMC Compatibility & ESD Protection  Provides protection for secondary side components  Maintains the managed Air flow paths in air-cooled applications
  • 10. REDI –Air Cool Mechanism  Secondary Side Cooling should be carefully evaluated particularly for 0.8” & 0.85” because of limited Gap between Secondary cover to PCB. This is likely to be High Pressure Flow path where cooling air requirements are high  Component Layout can be critical to proper plug-in unit Cooling. The Layout should consider the flow direction, shadowing effect, air preheating, re-circulation etc..  The Direction of Airflow should be as shown in image
  • 11. REDI –Air Cool Mechanism – Important Rules to Remember  Rule 7-4: Thickness of Plu-in unit that interface with sub Rack’s Card Guide shall be 1.6mm +-0.2mm. But if Thicker PCB is recommended, then the distance from Primary side of PCB to Outside of Secondary cover is to be maintained as per Pitch of Plug-in units  Rule 7-5: Covers shall be electrically connected to safety ground with resistance not to exceed 100mohm  Rule 7-9: Maximum Plug-in Width is defined by following Table  Rule 7-11, 7-12: Primary & Secondary Side Cover is mandatory for TYPE1 and it is not required for TYPE2 implementations  Rule 13-1: In Order to achieve 2 Level maintenance, Type1 Plu-in units shall comply with ESD requirements of VITA 47
  • 12. REDI –Conduction Cool Mechanism  REDI conduction Cool mechanism is defined by VITA 48.1  It defines the detailed mechanical implementation for conduction cool mechanism for PCB/Plug-In Units which is defined by VITA 46  In Conduction Cooled System, there are two important components namely Frame and Cover. Frame used to transfer the heat from PCB/components to Sub rack and Cover is used to cover the Both side of Plug-In units with support of ESD suppression  Cover Plate differentiates the TYPE1 & TYPE2 Cards  The PCB thickness can be variable from 0.06” [1.5mm] to 0.12”[3.048mm] and Even Thicker PCB also can be accommodated based on considering the Guide Rail Thickness and so PCB is limited on following  For Primary Side Retainer design – 0.137”[3.48mm]MAX  For secondary side Retainer Design – 0.112”[2.85mm]MAX
  • 13. REDI –Conduction Cool Mechanism  REDI conduction Cool mechanism defines 2 way implementation the Design based on retainer placement.  Primary Side Retainer  Secondary side Retainer
  • 14. REDI –Conduction Cool Mechanism  REDI conduction Cool mechanism Supports Connector Side Protections as it is indicated by image
  • 15. REDI –Conduction Cool Mechanism  REDI conduction Cool mechanism – Primary Side Retainer
  • 16. REDI –Conduction Cool Mechanism  REDI conduction Cool mechanism – Secondary Side Retainer
  • 17. REDI –Conduction Cool Mechanism  REDI conduction Cool mechanism – Retainer Position  Plug-In Unit along with Retainer plugged on Guide Rail of Chassis with Gap of 13.34mm  In Retainer Relaxed State, thermal interface side should not have any gap with Rack Wall and Retainer side will have 0.76mm gap. Total Plug-in unit Thickness on Guide Rail is 12.57mm  In Retainer tightened state, Total Plug-in Unit Thickness will be 13.3mm  Card Guide Depth is 9.19mm to 10.41mm
  • 18. REDI –Conduction Cool Mechanism – Guidance on Cooling  Component Layout can be critical to proper plug-in unit cooling. The layout should consider the how each component cooling, length and cross sectional area of heat transfer paths etc..  The conduction contact area for heat transfer from plug-in unit is dependant on several factors, including the depth of card, the presence of air cooled card guide projection.
  • 19. REDI –Conduction Cool Mechanism – Important Rules to Remember  Rule 6-1: For Type1 Implementations, Both Primary & Secondary side covers shall be required  Rule 6-12: Covers shall be electrically connected to safety ground with resistance not to exceed 100mohm  Rule 6-11: Maximum Plug-in Width is defined by following Table  Rule 7-11, 7-12: Primary & Secondary Side Cover is mandatory for TYPE1 and it is not required for TYPE2 implementations  Rule 13-1: In Order to achieve 2 Level maintenance, Type1 Plu-in units shall comply with ESD requirements of VITA 47
  • 20. REDI - VPX  Any Questions for Discussion..........