eNodeB
Basic Moshell Commands for RF
Engineer
S1-UP, S1-CP, S1, X2 Links
and Handover
How to verify connection between eNodeB an MME (S1-Control
Plane) after eNB or MME restart >st mme or st termpointtomme
• DFWe0600037> st mme
• 100727-13:22:42 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy Adm State Op. State MO
• ===================================================================================
• 886 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MME010012008226
• ===================================================================================
• Total: 1 MOs
• DFWe0600037> st termpointtomme
• 100727-13:23:01 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy Adm State Op. State MO
• ===================================================================================
• 886 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MME010012008226
• ===================================================================================
• Total: 1 MOs
To find out IP address for MME
>get <proxy#>
How to Verify connection between eNodeB to SGW S1-UP (S1 – User
Plane) after eNB or SGW restart
To verify S1-UP (link from eNodeB to S-GW), you have to run ping command from
UE to application server.
Ping <IP address> -t
How to verify connection X2 link (Links between eNB)
• DFWe0600037> st termpointtoenb
• 100727-14:28:05 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy Adm State Op. State MO
• ===================================================================================
• 684 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600671,TermPointToENB=DFWe0600671
• 692 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600008,TermPointToENB=DFWe0600008
• 694 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600029,TermPointToENB=DFWe0600029
• 703 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600607,TermPointToENB=DFWe0600607
• 708 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600049,TermPointToENB=DFWe0600049
• 712 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600674,TermPointToENB=DFWe0600674
• 718 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600055,TermPointToENB=DFWe0600055
• 722 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600007,TermPointToENB=DFWe0600007
• 725 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600036,TermPointToENB=DFWe0600036
• 730 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600044,TermPointToENB=DFWe0600044
This command will verify X2 links. A
maximum of 64 host MOs
(IpAccessHostGpb, IpAccessHostSpb
and IpAccessHostEt) can be
configured in a node.
A maximum of 64 host MOs
(IpAccessHostGpb, IpAccessHostSpb
and IpAccessHostEt) can be
connected to IpInterface MOs on one
board.
How to list relation
• DFWe0600037> pr relat
• 100727-14:44:06 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy MO
• ===================================================================================
• 633 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1
• 634 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000021
• 635 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06004332
• 636 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000061
• 637 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000443
• 638 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000482
• 639 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06004592
• 640 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000351
• 641 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000471
• 642 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000373
• 643 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000291
• 644 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06056744
• 645 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000072
• 646 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000492
• 647 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000062
• 648 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06050506
• 649 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000551
• 650 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000363
• 651 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06006742
How to check HO feature is ACTIVATED. If the feature doesn’t
activate, eNB will not able to do HO
• DFWe0600037> get intralte
• 100727-14:41:30 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• =========================================================================================================
========
• 21 SystemFunctions=1,Licensing=1,OptionalFeatures=1,IntraLTEHandover=1
• =========================================================================================================
========
• IntraLTEHandoverId 1
• featureStateIntraLTEHandover 1 (ACTIVATED)
• keyIdIntraLTEHandover CXC4010612
• licenseStateIntraLTEHandover 0 (DISABLED)
• serviceStateIntraLTEHandover 1 (OPERABLE)
• =========================================================================================================
========
• 30 SystemFunctions=1,Licensing=1,OptionalFeatures=1,IntraLTEHODataFwd=1
• =========================================================================================================
========
• IntraLTEHODataFwdId 1
• featureStateIntraLTEHODataFwd 0 (DEACTIVATED)
• keyIdIntraLTEHODataFwd CXC4010613
• licenseStateIntraLTEHODataFwd 0 (DISABLED)
• serviceStateIntraLTEHODataFwd 0 (INOPERABLE)
• =========================================================================================================
========
• Total: 2 MOs
How to Verify ipaccesshost for source eNB. Ipaccesshost is IP
> get ipaccesshostet
• DFWe0600037> get ipaccesshostet
• 100727-14:11:52 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• =============================================================================
====================================
• 620 IpSystem=1,IpAccessHostEt=1
• =============================================================================
====================================
• IpAccessHostEtId 1
• administrativeState 1 (UNLOCKED)
• availabilityStatus 0 (NO_STATUS)
• ipAddress 10.26.4.170
• ipDefaultTtl 64
• ipInterfaceMoRef
Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=2
• ntpDscp 54
• ntpServerMode 0 (DISABLED)
• operationalState 1 (ENABLED)
• reservedBy [1] =
• >>> reservedBy = IpSystem=1,IpAccessSctp=1
• userLabel
• =============================================================================
====================================
• Total: 1 MOs
To get ipaccesshost
For target eNB, from
X2 link. Select eNB
You want to get
Ipaccesshost and
type
>get <proxy>
eNB at Site Level
and and Cell Level
How to check status of cell and sector, lock/unlock cell
• DFWe0600037> st fdd
• 100727-14:46:20 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy Adm State Op. State MO
• ===================================================================================
• 628 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DFWe06000372
• 842 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DFWe06000373
• 889 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DFWe06000371
• ===================================================================================
• Total: 3 MOs
• DFWe0600037> st sec
• 100727-14:46:26 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy Adm State Op. State MO
• ===================================================================================
• 938 1 (UNLOCKED) 1 (ENABLED) SectorEquipmentFunction=S1
• 939 1 (UNLOCKED) 1 (ENABLED) SectorEquipmentFunction=S2
• 944 1 (UNLOCKED) 1 (ENABLED) SectorEquipmentFunction=S3
• ===================================================================================
• Total: 3 MOs
• DFWe0600531> bl cellfdd
• 100809-16:20:22 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/28360
• Block following MOs ?
• ===================================================================================
• 629 ENodeBFunction=1,EUtranCellFDD=DFWe06005311
• 903 ENodeBFunction=1,EUtranCellFDD=DFWe06005312
• 957 ENodeBFunction=1,EUtranCellFDD=DFWe06005313
• ===================================================================================
• Are you Sure [y/n] ?
• Yes for lock cell and No for unlock cell
• DFWe0600531> deb cellfdd
• 100809-16:27:04 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/28360
• Deblock following MOs ?
• ===================================================================================
• 629 ENodeBFunction=1,EUtranCellFDD=DFWe06005311
• 903 ENodeBFunction=1,EUtranCellFDD=DFWe06005312
• 957 ENodeBFunction=1,EUtranCellFDD=DFWe06005313
• ===================================================================================
• Are you Sure [y/n] ?
• Yes for l unlock cell and No for lock cell
How to verify eNodeB health check
• DFWe0600037> acc 0 starthealthcheck
• 100727-15:06:22 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• Call Action starthealthcheck on following MOs ?
• ===================================================================================
• 0 ManagedElement=1
• ===================================================================================
• Are you Sure [y/n] ? y
• =================================================================================================================
• Proxy MO Action Nr of Params
• =================================================================================================================
• 0 ManagedElement=1 startHealthCheck 0
• >>> Return value = 0 (STARTED)
• =================================================================================================================
• Total: 1 MOs attempted, 1 MOs actioned
How to show log status of cell
• DFWe0600037> llog
• 100727-15:07:20 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• $ llog
• --------------------------------------------------------------------------------
• 1. [00-00-00 00:00:00] 0x00000003 (2) Error log was cleared at last restart..
• --------------------------------------------------------------------------------
• 2. [70-01-01 00:00:12] 0xB0AD0001 (2) Board manager restart.. Reset aft
• --------------------------------------------------------------------------------
• 3. [10-07-04 00:23:52] 0xF0F0F0F2 (2) Recovery action, faultId: 0x203, (SwDow
• --------------------------------------------------------------------------------
• 4. [10-07-04 00:23:52] 0xB0AD0005 (2) Board manager restart escalate..
• --------------------------------------------------------------------------------
• 5. [10-07-10 14:42:49] 0xB0AD0002 (2) Board manager restart.. .
How to restart eNB
DFWe0600531> acc 0 manualrestart
100809-17:23:20 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/28638
Call Action manualrestart on following MOs ?
===================================================================================
0 ManagedElement=1
INFO: The RBS node DFWE0600531 will be restarted on CV: EnclosureProductDataMismatch_Fix
===================================================================================
Are you Sure [y/n] ? ….
How to check the software package of eNodeB
• DFWe0600037> pr upgrade
• 100727-14:49:14 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy MO
• ===================================================================================
• 205 SwManagement=1,UpgradeTrace=1
• 207 SwManagement=1,UpgradePackage=R20BT
• 233 SwManagement=1,UpgradePackage=CXP102051/1_R20DN
• 278 SwManagement=1,Repertoire=CPP_Control_Upgrade_2
• 436 SwManagement=1,UpgradePackage=CXP102051/1_R20GY
• 442 SwManagement=1,Repertoire=CPP_IP_Tran_Upgrade_2
• 490 SwManagement=1,UpgradePackage=InitialUP
• 597 SwManagement=1,UpgradePackage=CXP102051/1_R20EM
• ===================================================================================
• Total: 8 MOs
How to check CV
• DFWe0600037> cvcu
• 100727-14:50:13 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• =========================================================================================================
==========
• 100727-14:50 CV Name Upgrade Package Release
• =========================================================================================================
==========
• Startable: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1)
• Loaded: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1)
• Executing: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1)
• Last created: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1)
• -------------------------------------------------------------------------------------------------------------------
• Current UpgradePkg: UpgradePackage=CXP102051/1_R20GY CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1)
• AutoCreatedCV: Disabled
• Ongoing CV activity: 0 (IDLE)
• Rollback status: Rollback is on
• Rollback init timer: 30
• Rollback init counter: 2
• Rollback counter: 2
• Rollback list: s[2] = Internal_Relation_add_0607 Fi_CXP102051%1_R20DN_100428_0106
• =========================================================================================================
=============================
To delete old cv :
>cvrm <cv name>
To set new cv from the list:
>cvset <cv name>
To create cv after any change make:
>cvms <cv name> (Have to be a new name, can’t overwrite the old name).
Current CV
eNB Related Hardware
To List of RF ports, RI ports
• DFWe0600037> lpr rfport
• 100727-17:24:57 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy MO
• ===================================================================================
• 158 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=B
• 159 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=A
• 163 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=A
• 166 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=B
• 177 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=B
• 178 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=A
• ===================================================================================
• Total: 6 MOs
• DFWe0600037> lpr riport
• 100727-17:26:57 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy MO
• ===================================================================================
• 76 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=B
• 77 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=C
• 84 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=E
• 86 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=A
• 88 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=D
• 103 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=F
• 153 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_1
• 154 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_2
• 167 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_1
• 168 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_2
• 173 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_1
• 174 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_2
• ===================================================================================
• Total: 12 MOs
DUL
How to list of antennagroup (see attached diagram for all related MOs
• DFWe0600037> lpr antennaunitgroup
• 100727-17:28:00 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy MO
• ===================================================================================
• 123 Equipment=1,AntennaUnitGroup=1
• 124 Equipment=1,AntennaUnitGroup=1,RfBranch=2
• 125 Equipment=1,AntennaUnitGroup=1,RfBranch=1
• 126 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1
• 127 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1
• 128 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1,AuPort=2
• 129 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1,AuPort=1
• 182 Equipment=1,AntennaUnitGroup=3
• 183 Equipment=1,AntennaUnitGroup=3,RfBranch=2
• 184 Equipment=1,AntennaUnitGroup=3,RfBranch=1
• 185 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1
• 186 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1
• 187 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1,AuPort=2
• 188 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1,AuPort=1
• 196 Equipment=1,AntennaUnitGroup=2
• 197 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1
• 198 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1
• 199 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1,AuPort=1
• 200 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1,AuPort=2
• 201 Equipment=1,AntennaUnitGroup=2,RfBranch=2
• 202 Equipment=1,AntennaUnitGroup=2,RfBranch=1
• ===================================================================================
• Total: 21 MOs
How to verify IPinterdace (IP for GigB port)
• DFWe0600037> get interface addressactive
• 100727-15:02:46 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• =======================================================================
==========================================
• MO Attribute Value
• =======================================================================
==========================================
• Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=1
ownIpAddressActive xx.xx.xx.xx
• Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=2
ownIpAddressActive xx.xx.xx.xx
• =======================================================================
==========================================
• Total: 2 MOs
How to list radio board unit
• DFWe0600037> lst ru
• 100727-15:28:17 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy Adm State Op. State MO
• ===================================================================================
• 52 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,GeneralProcessorUnit=1
• 53 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,GeneralProcessorUnit=1,MediumAccessUnit=1
• 152 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5
• 153 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_1
• 154 0 (DISABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_2
• 155 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru
• 158 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=B
• 159 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=A
• 161 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1
• 162 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru
• 163 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=A
• 166 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=B
• 167 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_1
• 168 0 (DISABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_2
• 172 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3
• 173 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_1
• 174 0 (DISABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_2
• 175 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru
• 177 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=B
• 178 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=A
• ===================================================================================
• Total: 20 MOs
• DFWe0600037> st device
• 100727-15:04:15 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ===================================================================================
• Proxy Adm State Op. State MO
• ===================================================================================
• 71 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,DeviceGroup=dul
• 155 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru
• 162 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru
• 175 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru
• ===================================================================================
• Total: 4 MOs
Shows all RUS boards installed in the ENodeB
• DFWe0600531> cabx
• 100804-11:26:30 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/11419
• .
• =====================================================================================================
• SMN APN BOARD GREEN YELLOW RED PRODUCT NR REV DATE SERIAL NR TEMP COREMGR
• =====================================================================================================
• 0 1 DUL 20 01 ON OFF OFF KDU 137 533/3 R2C 20100406 C823455278
• -----------------------------------------------------------------------------------------------------
• ================================================================
• SMN ProductNr Rev Name Date SerialNr
• ================================================================
• 0 ROJ 999 999 * BACKPLANE
• ----------------------------------------------------------------
• =========================================================================================================
=======================
• SMN APN PORT BOARD GREEN YELLOW RED PRODUCT NR REV DATE SERIAL NR
• =========================================================================================================
=======================
• 0 1 BXP_0_1 RUS steady 16 off KRC 118 59/1 R2B 20100329 CC40857143
• 0 1 BXP_1_1 RUS steady 16 off KRC 118 59/1 R2B 20100331 CC40865276
• 0 1 BXP_2_1 RUS steady 16 off KRC 118 59/1 R2B 20100329 CC40857167
• ----------------------------------------------------------------------------------------------------------------------------
Synchronization
How to verify the sync
>get sync
• DFWe0600037> get sync
• 100727-15:09:42 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• =================================================================================================================
• 39 TransportNetwork=1,Synchronization=1
• =================================================================================================================
• SynchronizationId 1
• degradationIsFault 0 (DEGR_NOT_FAULT)
• nodeSystemClock 2 (LOCKED_MODE)
• syncRefActivity i[8] = 2 1 1 1 1 1 1 1
• syncRefPriority i[8] = 1 0 0 0 0 0 0 0
• syncRefStatus i[8] = 3 0 0 0 0 0 0 0
• syncReference [8] =
• >>> syncReference = Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1,TuSyncRef=1
• >>> syncReference =
• >>> syncReference =
• >>> syncReference =
• >>> syncReference =
• >>> syncReference =
• >>> syncReference =
• >>> syncReference =
• userLabel
• =================================================================================================================
• 95 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1,TuSyncRef=1
• =================================================================================================================
• TuSyncRefId 1
• administrativeState 1 (UNLOCKED)
• availabilityStatus 0 (NO_STATUS)
• operationalState 1 (ENABLED)
• reservedBy [1] =
• >>> reservedBy = TransportNetwork=1,Synchronization=1
• userLabel
• =================================================================================================================
• Total: 2 MOs
To verify status of sync device
• DFWe0600037> st sync
• 100727-15:10:29 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2
stopfile=/tmp/18164
• ===========================================================
========================
• Proxy Adm State Op. State MO
• ===========================================================
========================
• 95 1 (UNLOCKED) 1 (ENABLED)
Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1,TuSyncRef=1
• ===========================================================
========================
• Total: 1 MOs
To Verify handling of sync
• DFWe0600531> get . clock
• 100804-09:44:51 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2
stopfile=/tmp/11419
• ===========================================================
===================== =================================
• MO Attribute Value
• ===========================================================
===================== =================================
• Synchronization=1 nodeSystemClock 2 (LOC
KED_MODE)
• Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1 tuSystemClock 2
(LOC KED_MODE)
• ===========================================================
===================== =================================
0 UNKNOWN_MODE
1
STARTUP_MODE
The system clock is starting up.
2
LOCKED_MODE
The system clock signal on the Timing Unit is locked: a
synchronization reference is used to generate the system clock,
the clock accuracy is 50 ppb or better.
3
HOLD_OVER_MODE
The system clock signal on the Timing Unit has holdover quality: no
synchronization reference is used to generate the system clock,
the clock accuracy is 50 ppb or better.
4
FREE_RUNNING_MODE
The system clock signal on the Timing Unit is free-running: no
synchronization reference is used to generate the system clock,
the clock accuracy is 4.6 ppm or better.
5
FAILED_MODE
The system clock signal on the Timing Unit is failed: there is fault in
generating the system clock, no guarantee of clock accuracy
level.
6
LOSS_OF_TRACKING_MODE
The frequency of the system clock is at its upper or lower limit.
7
NOT_APPLICABLE
The system clock signal on Timing Unit is not applicable: the TUB or
the CBU is not present.
Alarm
How to check cell alarm
• DFWe0600037> alt
• 100727-15:13:11 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• Connecting to 10.26.4.174:56834 (CorbaSecurity=OFF, corba_class=2, java=1.6.0_13, jacoms=R71CD02, jacorb=R71AN04)
• Trying file=/var/opt/ericsson/amos/moshell_logfiles/edonngu/logs_moshell/tempfiles/20100727-131859_18123/ior18123
• Resolving the alarm service in OMS...
• Simple Alarm Client initialized...
• Starting to retrieve active alarms
• Nr of active alarms are: 4
• ================================================================================================
• Date & Time (Local) S Specific Problem Cause Mo-Reference
• ================================================================================================
• 2010-07-10 09:43:51 M TemperatureSensorFailure equipment_malfunction BatteryBackup=1
• 2010-07-10 09:43:51 M BatteryMissing configuration_or_customizing_error BatteryBackup=1
• 2010-07-10 09:44:41 C License Key File Fault configuration_or_customizing_error Licensing=1
• 2010-07-27 15:06:55 M Upgrade Package Corrupt file_error UpgradePackage=R20BT
• >>> Total: 4 Alarms (1 Critical, 3 Major)
How to check more detail on each alarm
• DFWe0600037> ala
• 100727-16:30:22 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• Connecting to 10.26.4.174:56834 (CorbaSecurity=OFF, corba_class=2, java=1.6.0_13, jacoms=R71CD02, jacorb=R71AN04)
• Trying file=/var/opt/ericsson/amos/moshell_logfiles/edonngu/logs_moshell/tempfiles/20100727-131859_18123/ior18123
• Resolving the alarm service in OMS...
• Simple Alarm Client initialized...
• Starting to retrieve active alarms
• Nr of active alarms are: 4
• ================================================================================================
• Sever Specific Problem Cause Mo-Reference
• ================================================================================================
• Crit License Key File Fault configuration_or_customizing_error Licensing=1
• Maj BatteryMissing configuration_or_customizing_error BatteryBackup=1
• Maj TemperatureSensorFailure equipment_malfunction BatteryBackup=1
• Maj Upgrade Package Corrupt file_error UpgradePackage=R20BT
• Alarm Id : SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-ENB,MeContext=DFWe0600037_5
• Event Time : Jul 10, 2010 9:44:41 AM
• Perceived Severity : Critical
• Managed Object Class : Licensing
• Managed Object Instance : SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-
ENB,MeContext=DFWe0600037,ManagedElement=1,SystemFunctions=1,Licensing=1
• Specific Problem : License Key File Fault
• Probable Cause : configuration_or_customizing_error
• Additional Text : No license key file installed
• Acknowledged by :
• Acknowledgement Time : 0
• Acknowledgement State: 2
• System DN : SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-ENB,MeContext=DFWe0600037
• Notification Id : 7
• Additional Info :
How to check cell alarm log
>lga or lga –xxd (number of days)
• DFWe0600531> lga -2d
• 100804-09:59:24 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/11419
• Trying password from ipdatabase file: /opt/ericsson/amos/moshell/sitefiles/ipdatabase...
• Startdate=19661031.081320, Enddate=20100805.145924
• ........Get /c/logfiles/alarm_event/ALARM_LOG.xml /var/opt/ericsson/amos/moshell_logfiles/edonngu/logs_moshell/tempfiles/20100803-162851_11377/alarmLog11419.xml
... OK
• ====================================================================================================================
• Timestamp (UTC) S Problem Cause MO-reference
• ====================================================================================================================
• 2010-03-28 21:49:57 AL m Password File Fault configuration_or_customizing_error Security=1
• 2010-03-28 21:50:00 AL C License Key File Fault configuration_or_customizing_error Licensing=1
• 2010-04-29 14:49:00 AL * License Key File Fault configuration_or_customizing_error Licensing=1
• 2010-04-29 14:49:36 AL m Password File Fault configuration_or_customizing_error Security=1
• 2010-04-29 14:49:40 AL C License Key File Fault configuration_or_customizing_error Licensing=1
• 2010-04-29 14:52:46 AL M Invalid Ethernet Optical Module replaceable_unit_type_mismatch
Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1
• 2010-04-29 14:52:52 AL * Invalid Ethernet Optical Module replaceable_unit_type_mismatch
Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1
• 2010-04-29 14:52:52 AL M Gigabit Ethernet Link Fault loss_of_signal Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1
• 2010-04-29 14:52:54 AL * Gigabit Ethernet Link Fault loss_of_signal Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1
• 2010-04-29 14:53:16 AL m Password File Fault configuration_or_customizing_error Security=1
• 2010-04-29 14:53:16 AL C License Key File Fault configuration_or_customizing_error Licensing=1
• 2010-04-29 19:54:32 AL M EnclosureProductDataMismatch configuration_or_customizing_error Cabinet=1
• 2010-04-29 19:54:53 AL * License Key File Fault configuration_or_customizing_error Licensing=1
• 2010-04-29 19:54:57 AL M LossOfMains commerical_power_failure HwUnit=PSU-1
• 2010-04-29 19:55:02 AL M TemperatureSensorFailure equipment_malfunction BatteryBackup=1
• 2010-04-29 19:55:02 AL M CircuitBreakerTripped fuse_failure HwUnit=BFU-1
• 2010-04-29 19:55:03 AL * CircuitBreakerTripped fuse_failure HwUnit=BFU-1
• 2010-04-29 19:55:03 AL M BatteryMissing configuration_or_customizing_error BatteryBackup=1
• 2010-04-29 19:55:05 AL M Disconnected equipment_malfunction HwUnit=PSU-3
• 2010-04-29 19:55:06 AL M Disconnected equipment_malfunction HwUnit=PDU-2
• 2010-04-29 19:55:06 AL M Disconnected equipment_malfunction HwUnit=SAU
• 2010-04-29 19:57:45 AL M LinkFailure link_failure Subrack=1,Slot=1,PlugInUnit=1,RiPort=A
How to check cell alarm log
>lgae or lgae –xxd (number of days)
• RNING - During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-
ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=PSU-1. =. =
• 2010-06-09 19:04:28 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected.
currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:28.580. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING -
During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-
ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=PSU-2. =. =
• 2010-06-09 19:04:30 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected.
currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:30.707. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING -
During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-
ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=PDU-1. =. =
• 2010-06-09 19:04:32 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected.
currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:32.915. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING -
During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-
ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=BFU-1. =. =
• 2010-06-09 19:04:34 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected.
currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:34.779. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING -
During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-
ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=SCU. =. =
• 2010-06-24 18:19:28 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
• 2010-06-24 18:19:41 EV Synchronization=1 NssSynchronization_SynchRefChanged
• 2010-06-24 18:19:41 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
• 2010-07-19 22:56:11 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
• 2010-07-19 22:56:22 EV Synchronization=1 NssSynchronization_SynchRefChanged
• 2010-07-19 22:56:22 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
• 2010-07-20 19:31:35 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
• 2010-07-20 19:31:46 EV Synchronization=1 NssSynchronization_SynchRefChanged
• 2010-07-20 19:31:46 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
• 2010-07-22 23:46:42 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
• 2010-07-22 23:46:53 EV Synchronization=1 NssSynchronization_SynchRefChanged
• 2010-07-22 23:46:53 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
eNB Power Setting, PCI, and
Miscellaneous
How to check eNB power seting
• DFWe0600037> get . power
• 100727-15:29:48 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• =================================================================================================================
• MO Attribute Value
• =================================================================================================================
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt CapacityOutputPowerId 60Watt
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt capacityUnitOutputPower Number of 60 Watt Licenses
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt keyIdOutputPower CXC4010626
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt licenseCapacityOutputPower 0
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt licenseStateOutputPower 0 (DISABLED)
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt CapacityOutputPowerId 40Watt
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt capacityUnitOutputPower Number of 40 Watt Licenses
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt keyIdOutputPower CXC4010625
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt licenseCapacityOutputPower 0
• Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt licenseStateOutputPower 0 (DISABLED)
• SubrackProdType=ROJ999999_* maxPowerDissipation 2000
• EUtranCellFDD=DFWe06000372 maximumTransmissionPower 406
• EUtranCellFDD=DFWe06000372 partOfRadioPower 100
• EUtranCellFDD=DFWe06000373 maximumTransmissionPower 406
• EUtranCellFDD=DFWe06000373 partOfRadioPower 100
• EUtranCellFDD=DFWe06000371 maximumTransmissionPower 406
• EUtranCellFDD=DFWe06000371 partOfRadioPower 100
• SectorEquipmentFunction=S1 confOutputPower 20
• SectorEquipmentFunction=S2 confOutputPower 20
• PowerSupply=1 PowerSupplyId 1
• PowerDistribution=1 PowerDistributionId 1
• SectorEquipmentFunction=S3 confOutputPower 20
• =================================================================================================================
• Total: 11 MOs
These are 3 key eNB power parameters
– partOfRadioPower
– confOutputPower
– maximumTransmissionPower
Detail on eNB power seting
Power per Radio Unit [W]:
H/W Capability
– Power capability limited by the RU hardware.
License Power Available
– Power capability as limited by power license management.
partOfRadioPower= 100 {0..100}
– Specifies fraction of power for LTE in case of shared RU.
confOutputPower= 20 {20, 40, 60, 80, 120} [W]
– Used to restrict power in the sector
How to change power setting
Example: change power on confoutputpower
• DFWe0600037> set SectorEquipmentFunction=S1 confoutputpower
40
• 100727-15:32:56 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2
stopfile=/tmp/18164
• Set confoutputpower on following MOs ?
• ===================================================
================================
• 938 SectorEquipmentFunction=S1
• ===================================================
================================
• Are you Sure [y/n] ?
• y
How to lock and un-lock cell
• DFWe0600037> bl cellfdd
• 100727-16:43:42 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• Block following MOs ?
• ===================================================================================
• 628 ENodeBFunction=1,EUtranCellFDD=DFWe06000372
• 842 ENodeBFunction=1,EUtranCellFDD=DFWe06000373
• 889 ENodeBFunction=1,EUtranCellFDD=DFWe06000371
• ===================================================================================
• Are you Sure [y/n] ? Y
• DFWe0600037> deb cellfdd
• 100727-16:45:02 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• Deblock following MOs ?
• ===================================================================================
• 628 ENodeBFunction=1,EUtranCellFDD=DFWe06000372
• 842 ENodeBFunction=1,EUtranCellFDD=DFWe06000373
• 889 ENodeBFunction=1,EUtranCellFDD=DFWe06000371
• ===================================================================================
• Are you Sure [y/n] ?
How to check Physical-layer Cell Identity (PCI)
• DFWe0600037> get utrancellfdd=dfwe0600037 cellid
• 100727-16:52:40 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• ============================================================================================
=====================
• MO Attribute Value
• ============================================================================================
=====================
• EUtranCellFDD=DFWe06000372 cellId 2
• EUtranCellFDD=DFWe06000372 physicalLayerCellIdGroup 145
• EUtranCellFDD=DFWe06000372 physicalLayerSubCellId 2
• EUtranCellFDD=DFWe06000373 cellId 3
• EUtranCellFDD=DFWe06000373 physicalLayerCellIdGroup 148
• EUtranCellFDD=DFWe06000373 physicalLayerSubCellId 1
• EUtranCellFDD=DFWe06000371 cellId 1
• EUtranCellFDD=DFWe06000371 physicalLayerCellIdGroup 143
• EUtranCellFDD=DFWe06000371 physicalLayerSubCellId 0
• ============================================================================================
=====================
• Total: 3 MOs
PCI sector 2 = 145*3 + 2 = 437. This is PCI UE detect and collection tool reports
Physical-layer Cell Identity (PCI)
• PSS signal: 3 different sequences called Physical-Layer Identities
(0-2)
• SSS signal: 168 different sequences called Physical-Layer Cell-
Identity groups (0-167)
• Because of 168 Physical-Layer Cell-Identity groups with 3
Physical-Layer, we will have 504 PCIs
168 × 3 = 504 Physical-Layer Cell Identities
• For each cell, PCIi = 3Sj + Pk
(Where i = 0 … 503; Group j = 0 … 167; ID k = 0 … 2)
How to check eNB parameters
• You need to dump the kget file from eNB
1. > l+ filenam
2. > kget all
3. >l-
Kget file will be stored in the location of current directory.
• Compare two eNB parameters
1. Take kget dump from eNB1, call it “kget_eNB1.log”
2. Moshell into eNB2
3. Do: diff . Kget_eNB1.log
How to Verify timer from active to idle
• DFWe0600037> get . tinactivity
• 100727-15:22:46 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• =======================================================================================
==========================
• MO Attribute Value
• =======================================================================================
==========================
• Rcs=1 tInactivityTimer 10
• =======================================================================================
==========================
• Total: 1 MOs
• DFWe0600037> set rcs=1 tinactivitytimer 60
• 100727-15:34:28 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164
• Set tinactivitytimer on following MOs ?
• ===================================================================================
• 935 ENodeBFunction=1,Rcs=1
• ===================================================================================
• Are you Sure [y/n] ?
• y
How to check numbers of active UE (not IMSI) only MME can look up
IMSI
• DFWe0600037> ue print -ue -allcell
• 100727-15:17:22 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2
stopfile=/tmp/18164
• $ ue print -ue -allcell
• CellId RacUeRef BbUeRef {traceRef,interfaces,traceDepth,ipAddress}
TypeOfActiveTrace SetByColi
• $
E nodeb useful commands for rf engineer

Mais conteúdo relacionado

Mais procurados

2 g parameters_guidelines1
2 g parameters_guidelines12 g parameters_guidelines1
2 g parameters_guidelines1James Mutuku
 
Ericsson optimization opti
Ericsson optimization optiEricsson optimization opti
Ericsson optimization optiTerra Sacrifice
 
Ericsson LTE Commands.pdf
Ericsson LTE Commands.pdfEricsson LTE Commands.pdf
Ericsson LTE Commands.pdfMbBot
 
Ericsson commond list, BSS+NSS=OSS
Ericsson commond list, BSS+NSS=OSSEricsson commond list, BSS+NSS=OSS
Ericsson commond list, BSS+NSS=OSSMd Shameem
 
Routing over ericsson mini link
Routing over ericsson mini linkRouting over ericsson mini link
Routing over ericsson mini linkAhmed Nabeeh
 
LTE KPI Optimization - A to Z Abiola.pptx
LTE KPI Optimization - A to Z Abiola.pptxLTE KPI Optimization - A to Z Abiola.pptx
LTE KPI Optimization - A to Z Abiola.pptxssuser574918
 
E2 e+call+setup+time+(cst)+enhacenments p3_benchmarking
E2 e+call+setup+time+(cst)+enhacenments p3_benchmarkingE2 e+call+setup+time+(cst)+enhacenments p3_benchmarking
E2 e+call+setup+time+(cst)+enhacenments p3_benchmarkingOtseakemhe
 
216506756-Moshell-Basic-Command-v1-0.ppt
216506756-Moshell-Basic-Command-v1-0.ppt216506756-Moshell-Basic-Command-v1-0.ppt
216506756-Moshell-Basic-Command-v1-0.pptssuser9e63c0
 
01 lte radio_parameters_lte_overview_rl1
01 lte radio_parameters_lte_overview_rl101 lte radio_parameters_lte_overview_rl1
01 lte radio_parameters_lte_overview_rl1Md.Akm Sahansha
 
Lte kpi accessability
Lte kpi accessabilityLte kpi accessability
Lte kpi accessabilityDheeraj Yadav
 
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2Mohamed Abd El Razek Bakry
 
RET configuration .ppt
RET configuration .pptRET configuration .ppt
RET configuration .pptRakeshPanda48
 
3 g rf_opt_process_ppt
3 g rf_opt_process_ppt3 g rf_opt_process_ppt
3 g rf_opt_process_pptHatim100
 
3 g parameter ericsson
3 g parameter ericsson3 g parameter ericsson
3 g parameter ericssonMitul Shah
 
LTE Review - Load Balancing and Interfreq HO
LTE Review - Load Balancing and Interfreq HOLTE Review - Load Balancing and Interfreq HO
LTE Review - Load Balancing and Interfreq HOpaulo_campolina
 

Mais procurados (20)

2 g parameters_guidelines1
2 g parameters_guidelines12 g parameters_guidelines1
2 g parameters_guidelines1
 
Evo bsc-8200
Evo bsc-8200Evo bsc-8200
Evo bsc-8200
 
Ericsson optimization opti
Ericsson optimization optiEricsson optimization opti
Ericsson optimization opti
 
Ericsson LTE Commands.pdf
Ericsson LTE Commands.pdfEricsson LTE Commands.pdf
Ericsson LTE Commands.pdf
 
Ericsson commond list, BSS+NSS=OSS
Ericsson commond list, BSS+NSS=OSSEricsson commond list, BSS+NSS=OSS
Ericsson commond list, BSS+NSS=OSS
 
Umts call-flows
Umts call-flowsUmts call-flows
Umts call-flows
 
Routing over ericsson mini link
Routing over ericsson mini linkRouting over ericsson mini link
Routing over ericsson mini link
 
LTE KPI Optimization - A to Z Abiola.pptx
LTE KPI Optimization - A to Z Abiola.pptxLTE KPI Optimization - A to Z Abiola.pptx
LTE KPI Optimization - A to Z Abiola.pptx
 
E2 e+call+setup+time+(cst)+enhacenments p3_benchmarking
E2 e+call+setup+time+(cst)+enhacenments p3_benchmarkingE2 e+call+setup+time+(cst)+enhacenments p3_benchmarking
E2 e+call+setup+time+(cst)+enhacenments p3_benchmarking
 
216506756-Moshell-Basic-Command-v1-0.ppt
216506756-Moshell-Basic-Command-v1-0.ppt216506756-Moshell-Basic-Command-v1-0.ppt
216506756-Moshell-Basic-Command-v1-0.ppt
 
UMTS/WCDMA Call Flows for Handovers
UMTS/WCDMA Call Flows for HandoversUMTS/WCDMA Call Flows for Handovers
UMTS/WCDMA Call Flows for Handovers
 
01 lte radio_parameters_lte_overview_rl1
01 lte radio_parameters_lte_overview_rl101 lte radio_parameters_lte_overview_rl1
01 lte radio_parameters_lte_overview_rl1
 
Lte signaling
Lte signalingLte signaling
Lte signaling
 
Lte kpi accessability
Lte kpi accessabilityLte kpi accessability
Lte kpi accessability
 
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2Ericsson RBS RET Alarms Troubleshooting Guide   Flow Chart v2
Ericsson RBS RET Alarms Troubleshooting Guide Flow Chart v2
 
RET configuration .ppt
RET configuration .pptRET configuration .ppt
RET configuration .ppt
 
3 g rf_opt_process_ppt
3 g rf_opt_process_ppt3 g rf_opt_process_ppt
3 g rf_opt_process_ppt
 
Irat handover basics
Irat handover basicsIrat handover basics
Irat handover basics
 
3 g parameter ericsson
3 g parameter ericsson3 g parameter ericsson
3 g parameter ericsson
 
LTE Review - Load Balancing and Interfreq HO
LTE Review - Load Balancing and Interfreq HOLTE Review - Load Balancing and Interfreq HO
LTE Review - Load Balancing and Interfreq HO
 

Destaque

Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...
Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...
Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...Ericsson
 
Dmcr lte trial feature
Dmcr lte trial featureDmcr lte trial feature
Dmcr lte trial featureAbhijeet Kumar
 
Lte power control
Lte power controlLte power control
Lte power controlPranay Akul
 
Ericsson License Assisted Access (LAA) January 2015
Ericsson License Assisted Access (LAA) January 2015Ericsson License Assisted Access (LAA) January 2015
Ericsson License Assisted Access (LAA) January 2015Ericsson
 
ดนตรีสากล
ดนตรีสากลดนตรีสากล
ดนตรีสากลKan Directioner
 
Hindi kavita laal tamatar
Hindi kavita  laal tamatarHindi kavita  laal tamatar
Hindi kavita laal tamatarRakhi Sharma
 
SMX Melbourne 2012 - Auditing PPC Campaigns - Leigh Hanney
SMX Melbourne 2012 - Auditing PPC Campaigns - Leigh HanneySMX Melbourne 2012 - Auditing PPC Campaigns - Leigh Hanney
SMX Melbourne 2012 - Auditing PPC Campaigns - Leigh HanneyLeigh Hanney
 
Tugas plkj
Tugas plkjTugas plkj
Tugas plkjhanif003
 
сравнение десятичных дробей
сравнение десятичных дробейсравнение десятичных дробей
сравнение десятичных дробейlena3357
 
E 12 bsp1779_pankajkumarvisualcv
E 12 bsp1779_pankajkumarvisualcvE 12 bsp1779_pankajkumarvisualcv
E 12 bsp1779_pankajkumarvisualcvPankaj Kumar
 
El aguila (2) vicente aj
El aguila (2) vicente ajEl aguila (2) vicente aj
El aguila (2) vicente ajESCO
 

Destaque (20)

Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...
Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...
Machine Learning Based Session Drop Prediction in LTE Networks and its SON As...
 
Pci group audit
Pci group auditPci group audit
Pci group audit
 
Dmcr lte trial feature
Dmcr lte trial featureDmcr lte trial feature
Dmcr lte trial feature
 
Lte power control
Lte power controlLte power control
Lte power control
 
Lte epc kp is and signalling (sf)
Lte epc kp is and signalling (sf)Lte epc kp is and signalling (sf)
Lte epc kp is and signalling (sf)
 
Ericsson License Assisted Access (LAA) January 2015
Ericsson License Assisted Access (LAA) January 2015Ericsson License Assisted Access (LAA) January 2015
Ericsson License Assisted Access (LAA) January 2015
 
Стимулирование органов местного самоуправления в Москве по итогам первого пол...
Стимулирование органов местного самоуправления в Москве по итогам первого пол...Стимулирование органов местного самоуправления в Москве по итогам первого пол...
Стимулирование органов местного самоуправления в Москве по итогам первого пол...
 
ดนตรีสากล
ดนตรีสากลดนตรีสากล
ดนตรีสากล
 
Green Jobs in Hawaii
Green Jobs in HawaiiGreen Jobs in Hawaii
Green Jobs in Hawaii
 
Spm report
Spm reportSpm report
Spm report
 
Государственная программа "Стимулирование экономической активности города Мос...
Государственная программа "Стимулирование экономической активности города Мос...Государственная программа "Стимулирование экономической активности города Мос...
Государственная программа "Стимулирование экономической активности города Мос...
 
Hindi kavita laal tamatar
Hindi kavita  laal tamatarHindi kavita  laal tamatar
Hindi kavita laal tamatar
 
Sec Presentation
Sec  PresentationSec  Presentation
Sec Presentation
 
Ihm2
Ihm2Ihm2
Ihm2
 
SMX Melbourne 2012 - Auditing PPC Campaigns - Leigh Hanney
SMX Melbourne 2012 - Auditing PPC Campaigns - Leigh HanneySMX Melbourne 2012 - Auditing PPC Campaigns - Leigh Hanney
SMX Melbourne 2012 - Auditing PPC Campaigns - Leigh Hanney
 
Tugas plkj
Tugas plkjTugas plkj
Tugas plkj
 
сравнение десятичных дробей
сравнение десятичных дробейсравнение десятичных дробей
сравнение десятичных дробей
 
T pack presentation
T pack presentationT pack presentation
T pack presentation
 
E 12 bsp1779_pankajkumarvisualcv
E 12 bsp1779_pankajkumarvisualcvE 12 bsp1779_pankajkumarvisualcv
E 12 bsp1779_pankajkumarvisualcv
 
El aguila (2) vicente aj
El aguila (2) vicente ajEl aguila (2) vicente aj
El aguila (2) vicente aj
 

Semelhante a E nodeb useful commands for rf engineer

E node b_useful_commands_for_rf_engineer
E node b_useful_commands_for_rf_engineerE node b_useful_commands_for_rf_engineer
E node b_useful_commands_for_rf_engineerMohamed Msuya
 
Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...
Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...
Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...Gera Shegalov
 
A deep dive about VIP,HAIP, and SCAN
A deep dive about VIP,HAIP, and SCAN A deep dive about VIP,HAIP, and SCAN
A deep dive about VIP,HAIP, and SCAN Riyaj Shamsudeen
 
OSMC 2008 | Monitoring MySQL by Geert Vanderkelen
OSMC 2008 | Monitoring MySQL by Geert VanderkelenOSMC 2008 | Monitoring MySQL by Geert Vanderkelen
OSMC 2008 | Monitoring MySQL by Geert VanderkelenNETWAYS
 
Formal Verification of Web Service Interaction Contracts
Formal Verification of Web Service Interaction ContractsFormal Verification of Web Service Interaction Contracts
Formal Verification of Web Service Interaction ContractsGera Shegalov
 
Compare mysql5.1.50 mysql5.5.8
Compare mysql5.1.50 mysql5.5.8Compare mysql5.1.50 mysql5.5.8
Compare mysql5.1.50 mysql5.5.8Philip Zhong
 
A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn...
 A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn... A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn...
A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn...Pooyan Jamshidi
 
421 Ch
421 Ch421 Ch
421 Chanjaan
 
Session 6 sv_randomization
Session 6 sv_randomizationSession 6 sv_randomization
Session 6 sv_randomizationNirav Desai
 
Mdp plus 2.1
Mdp plus 2.1Mdp plus 2.1
Mdp plus 2.1boedax
 
Altitude SF 2017: Debugging Fastly VCL 101
Altitude SF 2017: Debugging Fastly VCL 101Altitude SF 2017: Debugging Fastly VCL 101
Altitude SF 2017: Debugging Fastly VCL 101Fastly
 
Performance measurement and tuning
Performance measurement and tuningPerformance measurement and tuning
Performance measurement and tuningAOE
 
Labs_BT_20221017.pptx
Labs_BT_20221017.pptxLabs_BT_20221017.pptx
Labs_BT_20221017.pptxssuserb4d806
 
Writing efficient sql
Writing efficient sqlWriting efficient sql
Writing efficient sqlj9soto
 
glance replicator
glance replicatorglance replicator
glance replicatoririx_jp
 

Semelhante a E nodeb useful commands for rf engineer (20)

E node b_useful_commands_for_rf_engineer
E node b_useful_commands_for_rf_engineerE node b_useful_commands_for_rf_engineer
E node b_useful_commands_for_rf_engineer
 
Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...
Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...
Integrated Data, Message, and Process Recovery for Failure Masking in Web Ser...
 
A deep dive about VIP,HAIP, and SCAN
A deep dive about VIP,HAIP, and SCAN A deep dive about VIP,HAIP, and SCAN
A deep dive about VIP,HAIP, and SCAN
 
Advanced Cassandra
Advanced CassandraAdvanced Cassandra
Advanced Cassandra
 
OSMC 2008 | Monitoring MySQL by Geert Vanderkelen
OSMC 2008 | Monitoring MySQL by Geert VanderkelenOSMC 2008 | Monitoring MySQL by Geert Vanderkelen
OSMC 2008 | Monitoring MySQL by Geert Vanderkelen
 
Formal Verification of Web Service Interaction Contracts
Formal Verification of Web Service Interaction ContractsFormal Verification of Web Service Interaction Contracts
Formal Verification of Web Service Interaction Contracts
 
CodeIgniter 3.0
CodeIgniter 3.0CodeIgniter 3.0
CodeIgniter 3.0
 
Compare mysql5.1.50 mysql5.5.8
Compare mysql5.1.50 mysql5.5.8Compare mysql5.1.50 mysql5.5.8
Compare mysql5.1.50 mysql5.5.8
 
Ieee 1149.1-2013-tutorial-ijtag
Ieee 1149.1-2013-tutorial-ijtagIeee 1149.1-2013-tutorial-ijtag
Ieee 1149.1-2013-tutorial-ijtag
 
A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn...
 A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn... A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn...
A Framework for Robust Control of Uncertainty in Self-Adaptive Software Conn...
 
421 Ch
421 Ch421 Ch
421 Ch
 
Marat-Slides
Marat-SlidesMarat-Slides
Marat-Slides
 
3
33
3
 
Session 6 sv_randomization
Session 6 sv_randomizationSession 6 sv_randomization
Session 6 sv_randomization
 
Mdp plus 2.1
Mdp plus 2.1Mdp plus 2.1
Mdp plus 2.1
 
Altitude SF 2017: Debugging Fastly VCL 101
Altitude SF 2017: Debugging Fastly VCL 101Altitude SF 2017: Debugging Fastly VCL 101
Altitude SF 2017: Debugging Fastly VCL 101
 
Performance measurement and tuning
Performance measurement and tuningPerformance measurement and tuning
Performance measurement and tuning
 
Labs_BT_20221017.pptx
Labs_BT_20221017.pptxLabs_BT_20221017.pptx
Labs_BT_20221017.pptx
 
Writing efficient sql
Writing efficient sqlWriting efficient sql
Writing efficient sql
 
glance replicator
glance replicatorglance replicator
glance replicator
 

Último

System Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event SchedulingSystem Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event SchedulingBootNeck1
 
Energy Awareness training ppt for manufacturing process.pptx
Energy Awareness training ppt for manufacturing process.pptxEnergy Awareness training ppt for manufacturing process.pptx
Energy Awareness training ppt for manufacturing process.pptxsiddharthjain2303
 
welding defects observed during the welding
welding defects observed during the weldingwelding defects observed during the welding
welding defects observed during the weldingMuhammadUzairLiaqat
 
Virtual memory management in Operating System
Virtual memory management in Operating SystemVirtual memory management in Operating System
Virtual memory management in Operating SystemRashmi Bhat
 
Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...121011101441
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)Dr SOUNDIRARAJ N
 
Vishratwadi & Ghorpadi Bridge Tender documents
Vishratwadi & Ghorpadi Bridge Tender documentsVishratwadi & Ghorpadi Bridge Tender documents
Vishratwadi & Ghorpadi Bridge Tender documentsSachinPawar510423
 
Transport layer issues and challenges - Guide
Transport layer issues and challenges - GuideTransport layer issues and challenges - Guide
Transport layer issues and challenges - GuideGOPINATHS437943
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
Class 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm SystemClass 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm Systemirfanmechengr
 
US Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of ActionUS Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of ActionMebane Rash
 
Indian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.pptIndian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.pptMadan Karki
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort servicejennyeacort
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...Chandu841456
 
Earthing details of Electrical Substation
Earthing details of Electrical SubstationEarthing details of Electrical Substation
Earthing details of Electrical Substationstephanwindworld
 
Steel Structures - Building technology.pptx
Steel Structures - Building technology.pptxSteel Structures - Building technology.pptx
Steel Structures - Building technology.pptxNikhil Raut
 
Risk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfRisk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfROCENODodongVILLACER
 

Último (20)

System Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event SchedulingSystem Simulation and Modelling with types and Event Scheduling
System Simulation and Modelling with types and Event Scheduling
 
Energy Awareness training ppt for manufacturing process.pptx
Energy Awareness training ppt for manufacturing process.pptxEnergy Awareness training ppt for manufacturing process.pptx
Energy Awareness training ppt for manufacturing process.pptx
 
welding defects observed during the welding
welding defects observed during the weldingwelding defects observed during the welding
welding defects observed during the welding
 
Virtual memory management in Operating System
Virtual memory management in Operating SystemVirtual memory management in Operating System
Virtual memory management in Operating System
 
Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...Instrumentation, measurement and control of bio process parameters ( Temperat...
Instrumentation, measurement and control of bio process parameters ( Temperat...
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
 
Vishratwadi & Ghorpadi Bridge Tender documents
Vishratwadi & Ghorpadi Bridge Tender documentsVishratwadi & Ghorpadi Bridge Tender documents
Vishratwadi & Ghorpadi Bridge Tender documents
 
Transport layer issues and challenges - Guide
Transport layer issues and challenges - GuideTransport layer issues and challenges - Guide
Transport layer issues and challenges - Guide
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 
Class 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm SystemClass 1 | NFPA 72 | Overview Fire Alarm System
Class 1 | NFPA 72 | Overview Fire Alarm System
 
US Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of ActionUS Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of Action
 
Indian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.pptIndian Dairy Industry Present Status and.ppt
Indian Dairy Industry Present Status and.ppt
 
Design and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdfDesign and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdf
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...
 
Earthing details of Electrical Substation
Earthing details of Electrical SubstationEarthing details of Electrical Substation
Earthing details of Electrical Substation
 
Steel Structures - Building technology.pptx
Steel Structures - Building technology.pptxSteel Structures - Building technology.pptx
Steel Structures - Building technology.pptx
 
Risk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfRisk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdf
 

E nodeb useful commands for rf engineer

  • 2. S1-UP, S1-CP, S1, X2 Links and Handover
  • 3. How to verify connection between eNodeB an MME (S1-Control Plane) after eNB or MME restart >st mme or st termpointtomme • DFWe0600037> st mme • 100727-13:22:42 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy Adm State Op. State MO • =================================================================================== • 886 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MME010012008226 • =================================================================================== • Total: 1 MOs • DFWe0600037> st termpointtomme • 100727-13:23:01 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy Adm State Op. State MO • =================================================================================== • 886 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MME010012008226 • =================================================================================== • Total: 1 MOs To find out IP address for MME >get <proxy#>
  • 4. How to Verify connection between eNodeB to SGW S1-UP (S1 – User Plane) after eNB or SGW restart To verify S1-UP (link from eNodeB to S-GW), you have to run ping command from UE to application server. Ping <IP address> -t
  • 5. How to verify connection X2 link (Links between eNB) • DFWe0600037> st termpointtoenb • 100727-14:28:05 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy Adm State Op. State MO • =================================================================================== • 684 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600671,TermPointToENB=DFWe0600671 • 692 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600008,TermPointToENB=DFWe0600008 • 694 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600029,TermPointToENB=DFWe0600029 • 703 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600607,TermPointToENB=DFWe0600607 • 708 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600049,TermPointToENB=DFWe0600049 • 712 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600674,TermPointToENB=DFWe0600674 • 718 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600055,TermPointToENB=DFWe0600055 • 722 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600007,TermPointToENB=DFWe0600007 • 725 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600036,TermPointToENB=DFWe0600036 • 730 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtraNetwork=1,ExternalENodeBFunction=DFWe0600044,TermPointToENB=DFWe0600044 This command will verify X2 links. A maximum of 64 host MOs (IpAccessHostGpb, IpAccessHostSpb and IpAccessHostEt) can be configured in a node. A maximum of 64 host MOs (IpAccessHostGpb, IpAccessHostSpb and IpAccessHostEt) can be connected to IpInterface MOs on one board.
  • 6. How to list relation • DFWe0600037> pr relat • 100727-14:44:06 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy MO • =================================================================================== • 633 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1 • 634 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000021 • 635 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06004332 • 636 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000061 • 637 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000443 • 638 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000482 • 639 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06004592 • 640 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000351 • 641 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000471 • 642 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000373 • 643 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000291 • 644 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06056744 • 645 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000072 • 646 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000492 • 647 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000062 • 648 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06050506 • 649 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000551 • 650 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06000363 • 651 ENodeBFunction=1,EUtranCellFDD=DFWe06000372,EUtranFreqRelation=1,EUtranCellRelation=DFWe06006742
  • 7. How to check HO feature is ACTIVATED. If the feature doesn’t activate, eNB will not able to do HO • DFWe0600037> get intralte • 100727-14:41:30 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ========================================================================================================= ======== • 21 SystemFunctions=1,Licensing=1,OptionalFeatures=1,IntraLTEHandover=1 • ========================================================================================================= ======== • IntraLTEHandoverId 1 • featureStateIntraLTEHandover 1 (ACTIVATED) • keyIdIntraLTEHandover CXC4010612 • licenseStateIntraLTEHandover 0 (DISABLED) • serviceStateIntraLTEHandover 1 (OPERABLE) • ========================================================================================================= ======== • 30 SystemFunctions=1,Licensing=1,OptionalFeatures=1,IntraLTEHODataFwd=1 • ========================================================================================================= ======== • IntraLTEHODataFwdId 1 • featureStateIntraLTEHODataFwd 0 (DEACTIVATED) • keyIdIntraLTEHODataFwd CXC4010613 • licenseStateIntraLTEHODataFwd 0 (DISABLED) • serviceStateIntraLTEHODataFwd 0 (INOPERABLE) • ========================================================================================================= ======== • Total: 2 MOs
  • 8. How to Verify ipaccesshost for source eNB. Ipaccesshost is IP > get ipaccesshostet • DFWe0600037> get ipaccesshostet • 100727-14:11:52 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ============================================================================= ==================================== • 620 IpSystem=1,IpAccessHostEt=1 • ============================================================================= ==================================== • IpAccessHostEtId 1 • administrativeState 1 (UNLOCKED) • availabilityStatus 0 (NO_STATUS) • ipAddress 10.26.4.170 • ipDefaultTtl 64 • ipInterfaceMoRef Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=2 • ntpDscp 54 • ntpServerMode 0 (DISABLED) • operationalState 1 (ENABLED) • reservedBy [1] = • >>> reservedBy = IpSystem=1,IpAccessSctp=1 • userLabel • ============================================================================= ==================================== • Total: 1 MOs To get ipaccesshost For target eNB, from X2 link. Select eNB You want to get Ipaccesshost and type >get <proxy>
  • 9. eNB at Site Level and and Cell Level
  • 10. How to check status of cell and sector, lock/unlock cell • DFWe0600037> st fdd • 100727-14:46:20 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy Adm State Op. State MO • =================================================================================== • 628 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DFWe06000372 • 842 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DFWe06000373 • 889 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DFWe06000371 • =================================================================================== • Total: 3 MOs • DFWe0600037> st sec • 100727-14:46:26 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy Adm State Op. State MO • =================================================================================== • 938 1 (UNLOCKED) 1 (ENABLED) SectorEquipmentFunction=S1 • 939 1 (UNLOCKED) 1 (ENABLED) SectorEquipmentFunction=S2 • 944 1 (UNLOCKED) 1 (ENABLED) SectorEquipmentFunction=S3 • =================================================================================== • Total: 3 MOs • DFWe0600531> bl cellfdd • 100809-16:20:22 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/28360 • Block following MOs ? • =================================================================================== • 629 ENodeBFunction=1,EUtranCellFDD=DFWe06005311 • 903 ENodeBFunction=1,EUtranCellFDD=DFWe06005312 • 957 ENodeBFunction=1,EUtranCellFDD=DFWe06005313 • =================================================================================== • Are you Sure [y/n] ? • Yes for lock cell and No for unlock cell • DFWe0600531> deb cellfdd • 100809-16:27:04 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/28360 • Deblock following MOs ? • =================================================================================== • 629 ENodeBFunction=1,EUtranCellFDD=DFWe06005311 • 903 ENodeBFunction=1,EUtranCellFDD=DFWe06005312 • 957 ENodeBFunction=1,EUtranCellFDD=DFWe06005313 • =================================================================================== • Are you Sure [y/n] ? • Yes for l unlock cell and No for lock cell
  • 11. How to verify eNodeB health check • DFWe0600037> acc 0 starthealthcheck • 100727-15:06:22 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • Call Action starthealthcheck on following MOs ? • =================================================================================== • 0 ManagedElement=1 • =================================================================================== • Are you Sure [y/n] ? y • ================================================================================================================= • Proxy MO Action Nr of Params • ================================================================================================================= • 0 ManagedElement=1 startHealthCheck 0 • >>> Return value = 0 (STARTED) • ================================================================================================================= • Total: 1 MOs attempted, 1 MOs actioned How to show log status of cell • DFWe0600037> llog • 100727-15:07:20 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • $ llog • -------------------------------------------------------------------------------- • 1. [00-00-00 00:00:00] 0x00000003 (2) Error log was cleared at last restart.. • -------------------------------------------------------------------------------- • 2. [70-01-01 00:00:12] 0xB0AD0001 (2) Board manager restart.. Reset aft • -------------------------------------------------------------------------------- • 3. [10-07-04 00:23:52] 0xF0F0F0F2 (2) Recovery action, faultId: 0x203, (SwDow • -------------------------------------------------------------------------------- • 4. [10-07-04 00:23:52] 0xB0AD0005 (2) Board manager restart escalate.. • -------------------------------------------------------------------------------- • 5. [10-07-10 14:42:49] 0xB0AD0002 (2) Board manager restart.. . How to restart eNB DFWe0600531> acc 0 manualrestart 100809-17:23:20 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/28638 Call Action manualrestart on following MOs ? =================================================================================== 0 ManagedElement=1 INFO: The RBS node DFWE0600531 will be restarted on CV: EnclosureProductDataMismatch_Fix =================================================================================== Are you Sure [y/n] ? ….
  • 12. How to check the software package of eNodeB • DFWe0600037> pr upgrade • 100727-14:49:14 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy MO • =================================================================================== • 205 SwManagement=1,UpgradeTrace=1 • 207 SwManagement=1,UpgradePackage=R20BT • 233 SwManagement=1,UpgradePackage=CXP102051/1_R20DN • 278 SwManagement=1,Repertoire=CPP_Control_Upgrade_2 • 436 SwManagement=1,UpgradePackage=CXP102051/1_R20GY • 442 SwManagement=1,Repertoire=CPP_IP_Tran_Upgrade_2 • 490 SwManagement=1,UpgradePackage=InitialUP • 597 SwManagement=1,UpgradePackage=CXP102051/1_R20EM • =================================================================================== • Total: 8 MOs
  • 13. How to check CV • DFWe0600037> cvcu • 100727-14:50:13 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ========================================================================================================= ========== • 100727-14:50 CV Name Upgrade Package Release • ========================================================================================================= ========== • Startable: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1) • Loaded: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1) • Executing: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1) • Last created: Pre_Launch_Samsung_settings CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1) • ------------------------------------------------------------------------------------------------------------------- • Current UpgradePkg: UpgradePackage=CXP102051/1_R20GY CXP102051/1_R20GY L10 (EP19-CPP_7.0.3.10.1) • AutoCreatedCV: Disabled • Ongoing CV activity: 0 (IDLE) • Rollback status: Rollback is on • Rollback init timer: 30 • Rollback init counter: 2 • Rollback counter: 2 • Rollback list: s[2] = Internal_Relation_add_0607 Fi_CXP102051%1_R20DN_100428_0106 • ========================================================================================================= ============================= To delete old cv : >cvrm <cv name> To set new cv from the list: >cvset <cv name> To create cv after any change make: >cvms <cv name> (Have to be a new name, can’t overwrite the old name). Current CV
  • 15. To List of RF ports, RI ports • DFWe0600037> lpr rfport • 100727-17:24:57 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy MO • =================================================================================== • 158 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=B • 159 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=A • 163 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=A • 166 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=B • 177 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=B • 178 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=A • =================================================================================== • Total: 6 MOs • DFWe0600037> lpr riport • 100727-17:26:57 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy MO • =================================================================================== • 76 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=B • 77 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=C • 84 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=E • 86 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=A • 88 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=D • 103 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,RiPort=F • 153 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_1 • 154 Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_2 • 167 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_1 • 168 Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_2 • 173 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_1 • 174 Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_2 • =================================================================================== • Total: 12 MOs DUL
  • 16. How to list of antennagroup (see attached diagram for all related MOs • DFWe0600037> lpr antennaunitgroup • 100727-17:28:00 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy MO • =================================================================================== • 123 Equipment=1,AntennaUnitGroup=1 • 124 Equipment=1,AntennaUnitGroup=1,RfBranch=2 • 125 Equipment=1,AntennaUnitGroup=1,RfBranch=1 • 126 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1 • 127 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1 • 128 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1,AuPort=2 • 129 Equipment=1,AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1,AuPort=1 • 182 Equipment=1,AntennaUnitGroup=3 • 183 Equipment=1,AntennaUnitGroup=3,RfBranch=2 • 184 Equipment=1,AntennaUnitGroup=3,RfBranch=1 • 185 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1 • 186 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1 • 187 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1,AuPort=2 • 188 Equipment=1,AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1,AuPort=1 • 196 Equipment=1,AntennaUnitGroup=2 • 197 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1 • 198 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1 • 199 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1,AuPort=1 • 200 Equipment=1,AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1,AuPort=2 • 201 Equipment=1,AntennaUnitGroup=2,RfBranch=2 • 202 Equipment=1,AntennaUnitGroup=2,RfBranch=1 • =================================================================================== • Total: 21 MOs
  • 17. How to verify IPinterdace (IP for GigB port) • DFWe0600037> get interface addressactive • 100727-15:02:46 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ======================================================================= ========================================== • MO Attribute Value • ======================================================================= ========================================== • Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=1 ownIpAddressActive xx.xx.xx.xx • Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1,IpInterface=2 ownIpAddressActive xx.xx.xx.xx • ======================================================================= ========================================== • Total: 2 MOs
  • 18. How to list radio board unit • DFWe0600037> lst ru • 100727-15:28:17 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy Adm State Op. State MO • =================================================================================== • 52 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,GeneralProcessorUnit=1 • 53 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,GeneralProcessorUnit=1,MediumAccessUnit=1 • 152 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5 • 153 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_1 • 154 0 (DISABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,RiPort=DATA_2 • 155 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru • 158 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=B • 159 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru,RfPort=A • 161 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1 • 162 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru • 163 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=A • 166 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru,RfPort=B • 167 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_1 • 168 0 (DISABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,RiPort=DATA_2 • 172 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3 • 173 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_1 • 174 0 (DISABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,RiPort=DATA_2 • 175 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru • 177 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=B • 178 1 (UNLOCKED) 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru,RfPort=A • =================================================================================== • Total: 20 MOs • DFWe0600037> st device • 100727-15:04:15 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =================================================================================== • Proxy Adm State Op. State MO • =================================================================================== • 71 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,DeviceGroup=dul • 155 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=5,AuxPlugInUnit=RU-1-5,DeviceGroup=ru • 162 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=1,AuxPlugInUnit=RU-1-1,DeviceGroup=ru • 175 1 (ENABLED) Equipment=1,RbsSubrack=1,RbsSlot=3,AuxPlugInUnit=RU-1-3,DeviceGroup=ru • =================================================================================== • Total: 4 MOs
  • 19. Shows all RUS boards installed in the ENodeB • DFWe0600531> cabx • 100804-11:26:30 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/11419 • . • ===================================================================================================== • SMN APN BOARD GREEN YELLOW RED PRODUCT NR REV DATE SERIAL NR TEMP COREMGR • ===================================================================================================== • 0 1 DUL 20 01 ON OFF OFF KDU 137 533/3 R2C 20100406 C823455278 • ----------------------------------------------------------------------------------------------------- • ================================================================ • SMN ProductNr Rev Name Date SerialNr • ================================================================ • 0 ROJ 999 999 * BACKPLANE • ---------------------------------------------------------------- • ========================================================================================================= ======================= • SMN APN PORT BOARD GREEN YELLOW RED PRODUCT NR REV DATE SERIAL NR • ========================================================================================================= ======================= • 0 1 BXP_0_1 RUS steady 16 off KRC 118 59/1 R2B 20100329 CC40857143 • 0 1 BXP_1_1 RUS steady 16 off KRC 118 59/1 R2B 20100331 CC40865276 • 0 1 BXP_2_1 RUS steady 16 off KRC 118 59/1 R2B 20100329 CC40857167 • ----------------------------------------------------------------------------------------------------------------------------
  • 21. How to verify the sync >get sync • DFWe0600037> get sync • 100727-15:09:42 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ================================================================================================================= • 39 TransportNetwork=1,Synchronization=1 • ================================================================================================================= • SynchronizationId 1 • degradationIsFault 0 (DEGR_NOT_FAULT) • nodeSystemClock 2 (LOCKED_MODE) • syncRefActivity i[8] = 2 1 1 1 1 1 1 1 • syncRefPriority i[8] = 1 0 0 0 0 0 0 0 • syncRefStatus i[8] = 3 0 0 0 0 0 0 0 • syncReference [8] = • >>> syncReference = Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1,TuSyncRef=1 • >>> syncReference = • >>> syncReference = • >>> syncReference = • >>> syncReference = • >>> syncReference = • >>> syncReference = • >>> syncReference = • userLabel • ================================================================================================================= • 95 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1,TuSyncRef=1 • ================================================================================================================= • TuSyncRefId 1 • administrativeState 1 (UNLOCKED) • availabilityStatus 0 (NO_STATUS) • operationalState 1 (ENABLED) • reservedBy [1] = • >>> reservedBy = TransportNetwork=1,Synchronization=1 • userLabel • ================================================================================================================= • Total: 2 MOs
  • 22. To verify status of sync device • DFWe0600037> st sync • 100727-15:10:29 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • =========================================================== ======================== • Proxy Adm State Op. State MO • =========================================================== ======================== • 95 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1,TuSyncRef=1 • =========================================================== ======================== • Total: 1 MOs To Verify handling of sync • DFWe0600531> get . clock • 100804-09:44:51 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/11419 • =========================================================== ===================== ================================= • MO Attribute Value • =========================================================== ===================== ================================= • Synchronization=1 nodeSystemClock 2 (LOC KED_MODE) • Subrack=1,Slot=1,PlugInUnit=1,TimingUnit=1 tuSystemClock 2 (LOC KED_MODE) • =========================================================== ===================== ================================= 0 UNKNOWN_MODE 1 STARTUP_MODE The system clock is starting up. 2 LOCKED_MODE The system clock signal on the Timing Unit is locked: a synchronization reference is used to generate the system clock, the clock accuracy is 50 ppb or better. 3 HOLD_OVER_MODE The system clock signal on the Timing Unit has holdover quality: no synchronization reference is used to generate the system clock, the clock accuracy is 50 ppb or better. 4 FREE_RUNNING_MODE The system clock signal on the Timing Unit is free-running: no synchronization reference is used to generate the system clock, the clock accuracy is 4.6 ppm or better. 5 FAILED_MODE The system clock signal on the Timing Unit is failed: there is fault in generating the system clock, no guarantee of clock accuracy level. 6 LOSS_OF_TRACKING_MODE The frequency of the system clock is at its upper or lower limit. 7 NOT_APPLICABLE The system clock signal on Timing Unit is not applicable: the TUB or the CBU is not present.
  • 23. Alarm
  • 24. How to check cell alarm • DFWe0600037> alt • 100727-15:13:11 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • Connecting to 10.26.4.174:56834 (CorbaSecurity=OFF, corba_class=2, java=1.6.0_13, jacoms=R71CD02, jacorb=R71AN04) • Trying file=/var/opt/ericsson/amos/moshell_logfiles/edonngu/logs_moshell/tempfiles/20100727-131859_18123/ior18123 • Resolving the alarm service in OMS... • Simple Alarm Client initialized... • Starting to retrieve active alarms • Nr of active alarms are: 4 • ================================================================================================ • Date & Time (Local) S Specific Problem Cause Mo-Reference • ================================================================================================ • 2010-07-10 09:43:51 M TemperatureSensorFailure equipment_malfunction BatteryBackup=1 • 2010-07-10 09:43:51 M BatteryMissing configuration_or_customizing_error BatteryBackup=1 • 2010-07-10 09:44:41 C License Key File Fault configuration_or_customizing_error Licensing=1 • 2010-07-27 15:06:55 M Upgrade Package Corrupt file_error UpgradePackage=R20BT • >>> Total: 4 Alarms (1 Critical, 3 Major) How to check more detail on each alarm • DFWe0600037> ala • 100727-16:30:22 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • Connecting to 10.26.4.174:56834 (CorbaSecurity=OFF, corba_class=2, java=1.6.0_13, jacoms=R71CD02, jacorb=R71AN04) • Trying file=/var/opt/ericsson/amos/moshell_logfiles/edonngu/logs_moshell/tempfiles/20100727-131859_18123/ior18123 • Resolving the alarm service in OMS... • Simple Alarm Client initialized... • Starting to retrieve active alarms • Nr of active alarms are: 4 • ================================================================================================ • Sever Specific Problem Cause Mo-Reference • ================================================================================================ • Crit License Key File Fault configuration_or_customizing_error Licensing=1 • Maj BatteryMissing configuration_or_customizing_error BatteryBackup=1 • Maj TemperatureSensorFailure equipment_malfunction BatteryBackup=1 • Maj Upgrade Package Corrupt file_error UpgradePackage=R20BT • Alarm Id : SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-ENB,MeContext=DFWe0600037_5 • Event Time : Jul 10, 2010 9:44:41 AM • Perceived Severity : Critical • Managed Object Class : Licensing • Managed Object Instance : SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW- ENB,MeContext=DFWe0600037,ManagedElement=1,SystemFunctions=1,Licensing=1 • Specific Problem : License Key File Fault • Probable Cause : configuration_or_customizing_error • Additional Text : No license key file installed • Acknowledged by : • Acknowledgement Time : 0 • Acknowledgement State: 2 • System DN : SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW-ENB,MeContext=DFWe0600037 • Notification Id : 7 • Additional Info :
  • 25. How to check cell alarm log >lga or lga –xxd (number of days) • DFWe0600531> lga -2d • 100804-09:59:24 10.26.66.110 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/11419 • Trying password from ipdatabase file: /opt/ericsson/amos/moshell/sitefiles/ipdatabase... • Startdate=19661031.081320, Enddate=20100805.145924 • ........Get /c/logfiles/alarm_event/ALARM_LOG.xml /var/opt/ericsson/amos/moshell_logfiles/edonngu/logs_moshell/tempfiles/20100803-162851_11377/alarmLog11419.xml ... OK • ==================================================================================================================== • Timestamp (UTC) S Problem Cause MO-reference • ==================================================================================================================== • 2010-03-28 21:49:57 AL m Password File Fault configuration_or_customizing_error Security=1 • 2010-03-28 21:50:00 AL C License Key File Fault configuration_or_customizing_error Licensing=1 • 2010-04-29 14:49:00 AL * License Key File Fault configuration_or_customizing_error Licensing=1 • 2010-04-29 14:49:36 AL m Password File Fault configuration_or_customizing_error Security=1 • 2010-04-29 14:49:40 AL C License Key File Fault configuration_or_customizing_error Licensing=1 • 2010-04-29 14:52:46 AL M Invalid Ethernet Optical Module replaceable_unit_type_mismatch Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1 • 2010-04-29 14:52:52 AL * Invalid Ethernet Optical Module replaceable_unit_type_mismatch Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1 • 2010-04-29 14:52:52 AL M Gigabit Ethernet Link Fault loss_of_signal Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1 • 2010-04-29 14:52:54 AL * Gigabit Ethernet Link Fault loss_of_signal Subrack=1,Slot=1,PlugInUnit=1,ExchangeTerminalIp=1,GigaBitEthernet=1 • 2010-04-29 14:53:16 AL m Password File Fault configuration_or_customizing_error Security=1 • 2010-04-29 14:53:16 AL C License Key File Fault configuration_or_customizing_error Licensing=1 • 2010-04-29 19:54:32 AL M EnclosureProductDataMismatch configuration_or_customizing_error Cabinet=1 • 2010-04-29 19:54:53 AL * License Key File Fault configuration_or_customizing_error Licensing=1 • 2010-04-29 19:54:57 AL M LossOfMains commerical_power_failure HwUnit=PSU-1 • 2010-04-29 19:55:02 AL M TemperatureSensorFailure equipment_malfunction BatteryBackup=1 • 2010-04-29 19:55:02 AL M CircuitBreakerTripped fuse_failure HwUnit=BFU-1 • 2010-04-29 19:55:03 AL * CircuitBreakerTripped fuse_failure HwUnit=BFU-1 • 2010-04-29 19:55:03 AL M BatteryMissing configuration_or_customizing_error BatteryBackup=1 • 2010-04-29 19:55:05 AL M Disconnected equipment_malfunction HwUnit=PSU-3 • 2010-04-29 19:55:06 AL M Disconnected equipment_malfunction HwUnit=PDU-2 • 2010-04-29 19:55:06 AL M Disconnected equipment_malfunction HwUnit=SAU • 2010-04-29 19:57:45 AL M LinkFailure link_failure Subrack=1,Slot=1,PlugInUnit=1,RiPort=A
  • 26. How to check cell alarm log >lgae or lgae –xxd (number of days) • RNING - During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW- ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=PSU-1. =. = • 2010-06-09 19:04:28 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected. currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:28.580. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING - During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW- ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=PSU-2. =. = • 2010-06-09 19:04:30 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected. currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:30.707. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING - During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW- ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=PDU-1. =. = • 2010-06-09 19:04:32 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected. currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:32.915. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING - During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW- ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=BFU-1. =. = • 2010-06-09 19:04:34 EV UpgradePackage=CXP102051/1_R20GY UpgradePackage Warning: Unexpected condition detected. currentStepLabel=HardINITIATE. TimeStamp=Date: 2010-06-09, Time: 19:04:34.779. Version=SU_SW: DeltaUPs - R71CD04. Slogan=WARNING - During reconfiguration of programs, no SwAllocation found for PlugInUnit: SubNetwork=ONRM_ROOT_MO_R,SubNetwork=DFW- ENB,MeContext=DFWe0600037,ManagedElement=1,Equipment=1,HwUnit=SCU. =. = • 2010-06-24 18:19:28 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged • 2010-06-24 18:19:41 EV Synchronization=1 NssSynchronization_SynchRefChanged • 2010-06-24 18:19:41 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged • 2010-07-19 22:56:11 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged • 2010-07-19 22:56:22 EV Synchronization=1 NssSynchronization_SynchRefChanged • 2010-07-19 22:56:22 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged • 2010-07-20 19:31:35 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged • 2010-07-20 19:31:46 EV Synchronization=1 NssSynchronization_SynchRefChanged • 2010-07-20 19:31:46 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged • 2010-07-22 23:46:42 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged • 2010-07-22 23:46:53 EV Synchronization=1 NssSynchronization_SynchRefChanged • 2010-07-22 23:46:53 EV Synchronization=1 NssSynchronization_SystemClockStatusChanged
  • 27. eNB Power Setting, PCI, and Miscellaneous
  • 28. How to check eNB power seting • DFWe0600037> get . power • 100727-15:29:48 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ================================================================================================================= • MO Attribute Value • ================================================================================================================= • Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt CapacityOutputPowerId 60Watt • Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt capacityUnitOutputPower Number of 60 Watt Licenses • Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt keyIdOutputPower CXC4010626 • Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt licenseCapacityOutputPower 0 • Licensing=1,CapacityLicenses=1,CapacityOutputPower=60Watt licenseStateOutputPower 0 (DISABLED) • Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt CapacityOutputPowerId 40Watt • Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt capacityUnitOutputPower Number of 40 Watt Licenses • Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt keyIdOutputPower CXC4010625 • Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt licenseCapacityOutputPower 0 • Licensing=1,CapacityLicenses=1,CapacityOutputPower=40Watt licenseStateOutputPower 0 (DISABLED) • SubrackProdType=ROJ999999_* maxPowerDissipation 2000 • EUtranCellFDD=DFWe06000372 maximumTransmissionPower 406 • EUtranCellFDD=DFWe06000372 partOfRadioPower 100 • EUtranCellFDD=DFWe06000373 maximumTransmissionPower 406 • EUtranCellFDD=DFWe06000373 partOfRadioPower 100 • EUtranCellFDD=DFWe06000371 maximumTransmissionPower 406 • EUtranCellFDD=DFWe06000371 partOfRadioPower 100 • SectorEquipmentFunction=S1 confOutputPower 20 • SectorEquipmentFunction=S2 confOutputPower 20 • PowerSupply=1 PowerSupplyId 1 • PowerDistribution=1 PowerDistributionId 1 • SectorEquipmentFunction=S3 confOutputPower 20 • ================================================================================================================= • Total: 11 MOs These are 3 key eNB power parameters – partOfRadioPower – confOutputPower – maximumTransmissionPower
  • 29. Detail on eNB power seting Power per Radio Unit [W]: H/W Capability – Power capability limited by the RU hardware. License Power Available – Power capability as limited by power license management. partOfRadioPower= 100 {0..100} – Specifies fraction of power for LTE in case of shared RU. confOutputPower= 20 {20, 40, 60, 80, 120} [W] – Used to restrict power in the sector
  • 30. How to change power setting Example: change power on confoutputpower • DFWe0600037> set SectorEquipmentFunction=S1 confoutputpower 40 • 100727-15:32:56 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • Set confoutputpower on following MOs ? • =================================================== ================================ • 938 SectorEquipmentFunction=S1 • =================================================== ================================ • Are you Sure [y/n] ? • y
  • 31. How to lock and un-lock cell • DFWe0600037> bl cellfdd • 100727-16:43:42 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • Block following MOs ? • =================================================================================== • 628 ENodeBFunction=1,EUtranCellFDD=DFWe06000372 • 842 ENodeBFunction=1,EUtranCellFDD=DFWe06000373 • 889 ENodeBFunction=1,EUtranCellFDD=DFWe06000371 • =================================================================================== • Are you Sure [y/n] ? Y • DFWe0600037> deb cellfdd • 100727-16:45:02 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • Deblock following MOs ? • =================================================================================== • 628 ENodeBFunction=1,EUtranCellFDD=DFWe06000372 • 842 ENodeBFunction=1,EUtranCellFDD=DFWe06000373 • 889 ENodeBFunction=1,EUtranCellFDD=DFWe06000371 • =================================================================================== • Are you Sure [y/n] ?
  • 32. How to check Physical-layer Cell Identity (PCI) • DFWe0600037> get utrancellfdd=dfwe0600037 cellid • 100727-16:52:40 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ============================================================================================ ===================== • MO Attribute Value • ============================================================================================ ===================== • EUtranCellFDD=DFWe06000372 cellId 2 • EUtranCellFDD=DFWe06000372 physicalLayerCellIdGroup 145 • EUtranCellFDD=DFWe06000372 physicalLayerSubCellId 2 • EUtranCellFDD=DFWe06000373 cellId 3 • EUtranCellFDD=DFWe06000373 physicalLayerCellIdGroup 148 • EUtranCellFDD=DFWe06000373 physicalLayerSubCellId 1 • EUtranCellFDD=DFWe06000371 cellId 1 • EUtranCellFDD=DFWe06000371 physicalLayerCellIdGroup 143 • EUtranCellFDD=DFWe06000371 physicalLayerSubCellId 0 • ============================================================================================ ===================== • Total: 3 MOs PCI sector 2 = 145*3 + 2 = 437. This is PCI UE detect and collection tool reports
  • 33. Physical-layer Cell Identity (PCI) • PSS signal: 3 different sequences called Physical-Layer Identities (0-2) • SSS signal: 168 different sequences called Physical-Layer Cell- Identity groups (0-167) • Because of 168 Physical-Layer Cell-Identity groups with 3 Physical-Layer, we will have 504 PCIs 168 × 3 = 504 Physical-Layer Cell Identities • For each cell, PCIi = 3Sj + Pk (Where i = 0 … 503; Group j = 0 … 167; ID k = 0 … 2)
  • 34. How to check eNB parameters • You need to dump the kget file from eNB 1. > l+ filenam 2. > kget all 3. >l- Kget file will be stored in the location of current directory. • Compare two eNB parameters 1. Take kget dump from eNB1, call it “kget_eNB1.log” 2. Moshell into eNB2 3. Do: diff . Kget_eNB1.log
  • 35. How to Verify timer from active to idle • DFWe0600037> get . tinactivity • 100727-15:22:46 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • ======================================================================================= ========================== • MO Attribute Value • ======================================================================================= ========================== • Rcs=1 tInactivityTimer 10 • ======================================================================================= ========================== • Total: 1 MOs • DFWe0600037> set rcs=1 tinactivitytimer 60 • 100727-15:34:28 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • Set tinactivitytimer on following MOs ? • =================================================================================== • 935 ENodeBFunction=1,Rcs=1 • =================================================================================== • Are you Sure [y/n] ? • y
  • 36. How to check numbers of active UE (not IMSI) only MME can look up IMSI • DFWe0600037> ue print -ue -allcell • 100727-15:17:22 10.26.4.174 8.0d ERBS_NODE_MODEL_A_9_2 stopfile=/tmp/18164 • $ ue print -ue -allcell • CellId RacUeRef BbUeRef {traceRef,interfaces,traceDepth,ipAddress} TypeOfActiveTrace SetByColi • $