2. WhyWhy DaikinDaikin promotes inverter technologypromotes inverter technology
1982 : Daikin started Launching of VRV first in the world
AND have used inverter technology since early days andhave used inverter technology since early days and
has gained much trust.has gained much trust.
2009 : Daikin still use Inverter for new model
3. How does it work?How does it work?
Mechanical
Compressor discharge volume adjustment
Loading/Unloading system Inverter system
Electrical
ConfidentialConfidential
To release some portion of
refrigerant gas mechanically
without compression.
Digital scroll compressor used in YDSDigital scroll compressor used in YDS
To change compressor speed
electrically.
Technology used in VRVTechnology used in VRV
4. Comparison of compressorsComparison of compressors
TypeType Digital scrollDigital scroll DC inverter scrollDC inverter scroll
Capacity controlCapacity control Loading/Unloading systemLoading/Unloading system Inverter systemInverter system
EfficiencyEfficiency FullFull
capacitycapacity
[100%Loa[100%Loa
ding]ding]
GoodGood
(because of low(because of low
compression loss)compression loss)
○○ High efficiency.High efficiency. ○○
MediumMedium
capacitycapacity
PoorPoor
(because of big(because of big
compression loss)compression loss)
△△ ExcellentExcellent ◎◎
LowLow
capacitycapacity
Continuous operationContinuous operation
control is rathercontrol is rather
difficult (Especially indifficult (Especially in
heating)heating)
×× ExcellentExcellent ◎◎
ConfidentialConfidential
5. Comparison of compressorsComparison of compressors
TypeType Digital scrollDigital scroll DC inverter scrollDC inverter scroll
CapacityCapacity
controlcontrol
Loading/Unloading systemLoading/Unloading system Inverter systemInverter system
NoiseNoise Very noisyVery noisy
(due to solenoid valve(due to solenoid valve
switching noise)switching noise)
×× Noisy at high speedNoisy at high speed
operation.operation.
△△
Weight SizeWeight Size Bigger size and heavier.Bigger size and heavier. ○○ Smaller size and lighterSmaller size and lighter ◎◎
ConstructionConstruction complicated mechanismcomplicated mechanism
(solenoid valve and(solenoid valve and
control pressure piping)control pressure piping)
○○ Simple mechanism withSimple mechanism with
inverter controllerinverter controller
○○
ConfidentialConfidential
6. INVERTER control.INVERTER control.
Low efficiency because of constant speed.Low efficiency because of constant speed.
Slow response because of solenoid valves.Slow response because of solenoid valves.
Heavy mechanical burden.Heavy mechanical burden.
Troublesome complicated mechanism.Troublesome complicated mechanism.
Solution: smoothSolution: smooth
and variableand variable
compressor speed.compressor speed.
Target: Smooth control of refrigerant flow to follow actual load variationTarget: Smooth control of refrigerant flow to follow actual load variation
with as little inertia as possible.with as little inertia as possible.
ConfidentialConfidential
Negative point of unloading system.
7. Solution the case of inverter.Solution the case of inverter.
Target: Smooth control of refrigerant flow to follow actualTarget: Smooth control of refrigerant flow to follow actual
load variation with as little inertia as possible.load variation with as little inertia as possible.
Motor speed direct control.Motor speed direct control.
Quick response by electronics control.Quick response by electronics control.
Simple mechanism.Simple mechanism.
Benefits of inverterBenefits of inverter
Perfect solutionPerfect solution
ConfidentialConfidential
8. 0
5
1 0
1 5
20
25
30
35
VRV
YDS
Starting electrical current levelStarting electrical current level
TT
No rush currentNo rush current
ConfidentialConfidential
Low electric facility cost.Low electric facility cost.
10. Advantage of CDU betweenAdvantage of CDU between
VRVIII&YDSVRVIII&YDS
Save EnergySave Energy
Save SpaceSave Space
ElectricalElectrical
Noise of CDUNoise of CDU
PipingPiping
High Static FanHigh Static Fan
Easy Installation and MaintenanceEasy Installation and Maintenance
16. Case Study Energy SavingCase Study Energy Saving
DESCRIPTION DAIKIN " V R V system" YDS
(Baht) (Baht)
1 INITIAL COST 4,160,000 2,912,000
( Machine, Equipment & System )
2 OPREATING COST / YEAR
2.1 Electical Expense 784,896 1,049,798
(Avg.0.8~1.1 Kw/TR X 64 TR at 70 % Usage x15Hrs/Day x 365
Days/Yr x 3.0 ฿/kWHr)
(Avg.1.0~1.2 Kw/TR X 125 TR at 70 % Usage x15Hrs/Day x
365 Days/Yr x 3.0 ฿/kWHr)
Sum 2.1~2.3 784,896 1,049,798
3 Life Time (Years) 20 15
(Because this system is scrol compressor
and inverter system)
Daikin Save Electric 265,000 Baht/YearDaikin Save Electric 265,000 Baht/Year
Pay Back Period 4.7 YearsPay Back Period 4.7 Years
23. Installation space comparisonInstallation space comparison
Space
47% Space saved47% Space savedW
L
Installation: installation spaceInstallation: installation space (10HP unit)(10HP unit)
York Digital ScrollYork Digital Scroll DaikinDaikin
LL WW surfacesurface LL WW surfacesurface
16301630 830830 1.351.35 930930 765765 0.7170.717
ConfidentialConfidential
25. NOISE OF CDU
York Digital Scroll [YDS]
6262626262626262626260606060585858585858
----
YDSYDS
64646262626262626363606060606060585857575454VRV IIIVRV III
2626242422222020181816161414121210108855
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
26. NOISE OF CDU
York Digital Scroll [YDS]
64646464646464646464646464646464626262626262YDSYDS
67676767676765656464656566666565636365656464VRV IIIVRV III
48484646444442424040383836363434323230302828
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
27. NOISE OF CDU
York Digital Scroll [YDS]
6565656565656565656565656565YDSYDS
--------------------686867676767VRV IIIVRV III
64646262606058585656545452525050
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
6565
32. VRV better than YDSVRV better than YDS
Daikin VRV III SystemDaikin VRV III System York Digital Scroll SystemYork Digital Scroll System
Connectable No.Connectable No. of IUof IU 64 Units64 Units 64 Units64 Units
Refrigerant Piping LengthRefrigerant Piping Length 1000 m1000 m 200-300 m200-300 m
Level differenceLevel difference 50-90 m50-90 m 50 m50 m
Max Pipe Length between FCU&CDUMax Pipe Length between FCU&CDU 165 m165 m 150 m150 m
Different Ventical Indoor UnitDifferent Ventical Indoor Unit 15 m15 m 15 m15 m
Improved Specs. for Large Building UseImproved Specs. for Large Building Use
35. No 1 High Static FanNo 1 High Static Fan
78.4 Pa E.S.P.78.4 Pa E.S.P.
Suitable for floor bySuitable for floor by
floor installationfloor installation
36. Easy installation and maintenance
1 Auto test
Back-up function3
2 Auto storage of operating data
37. Indoor Addressing Indoor Addressing
Automatic
Manual
Requires DIP
Switch Setting
DAIKIN VRV Digital Scroll
1. Automatic test
38. Automatic
operation data
storage of last
3 minutes just
before the
trouble
3 min.
2. Automatic storage of operating data
Service checker
to identify location
of problem and
cause of
malfunction
Implementation of
measures to
eliminate cause of
malfunction
Operating
MalfunctionMalfunction
The operation data can
be retrieved by the
service checker.
In case of malfunction, the system is storing the operation
data for the last 3 min of operation
40. Advantage of FCU betweenAdvantage of FCU between
VRVIII&YDSVRVIII&YDS
Daikin have more line upDaikin have more line up
[New] Middle/High ESP Duct Type[New] Middle/High ESP Duct Type
[New] Cassette Round Flow[New] Cassette Round Flow
Noise of FCUNoise of FCU
42. Indoor units line UP
11 types
York Digital Scroll [YDS]
79 models
10 types
49 models
Big four Way CassetteBig four Way Cassette
Compact Four Way Cassette
Duct Type
Low Static Pressure Duct Type
10HP Mid&High Static Pressure Duct Unit
Wall Mounted Type
Ceilling & Floor Type
High Static Pressure Duct
Type
Slim Duct Type
One Way Cassette Type
43. Middle/High ESP Duct TypeMiddle/High ESP Duct Type
Daikin Only OneDaikin Only One
44. Special Feature for Installer !
Middle/High ESP Duct Type FCUMiddle/High ESP Duct Type FCU
14 Steps Airflow Adjustment !!
By Remote control
45. [New] Ceilling Mounted Cassette[New] Ceilling Mounted Cassette
Round FlowRound Flow
Daikin Only OneDaikin Only One
46. TypeType
INDEXINDEX
2525 3232 4040 5050 6363 8080 100100 125125
Ceiling MountedCeiling Mounted
Cassette TypeCassette Type
FXFQ-PVEFXFQ-PVE
NewNew NewNew NewNew NewNew
Ceiling Mounted Cassette Type (Round Flow)Ceiling Mounted Cassette Type (Round Flow)
•Market expansion by launching Daikin unique product.Market expansion by launching Daikin unique product.
•Complete shift from Multi-flow to Round-flowComplete shift from Multi-flow to Round-flow
( VRV R-410A series)( VRV R-410A series)
NewNewNewNewNewNewNewNew
The Aim of development / INDEX RangeThe Aim of development / INDEX Range
IDU FXFQ25-125P
48. NOISE OF FCU
York Digital Scroll [YDS]
Big four Way Cassette TypeBig four Way Cassette Type
Compact Four Way Cassette Type
Ceiling mounted Cassette Type
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 200200 250250
VRV IIIVRV III 30/2730/27 30/2730/27 31/2731/27 32/2732/27 33/2833/28 36/3136/31 39/3339/33 42/3642/36
YDSYDS
41/38/341/38/3 41/38/341/38/3 44/42/344/42/3 44/42/344/42/3 46/44/446/44/4 46/44/446/44/4 48/46/448/46/4 48/46/448/46/4
[Round & Muilti Flow]
49. York Digital Scroll [YDS]
Ceiling mounted Cassette Type [Double Flow]
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 200200 250250
VRV IIIVRV III 32/2732/27 34/2834/28 34/2834/28 34/2934/29 34/2934/29 37/3237/32 39/3439/34 44/3844/38
YDSYDS
50. York Digital Scroll [YDS]
Ceiling mounted Cassette Corner Type
One Way Cassette Type
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 200200 250250
VRV IIIVRV III 38/3338/33 38/3338/33 40/3440/34 42/3742/37
YDSYDS
42/40/342/40/3 42/40/342/40/3 47/45/447/45/4 47/45/447/45/4 48/45/448/45/4
51. York Digital Scroll [YDS]
Slim Ceiling Mounted Duct Type
Low Static Pressure Duct Type
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 200200 250250
VRV IIIVRV III 33/2933/29 33/2933/29 33/2933/29 34/3034/30 35/3135/31 36/3236/32
YDSYDS
42/40/342/40/3 42/40/342/40/3 47/45/447/45/4 47/45/447/45/4 47/45/447/45/4
52. York Digital Scroll [YDS]
Duct Type
Ceiling Mounted Built-in
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 140140 --
VRV IIIVRV III 37/3237/32 37/3237/32 38/3238/32 38/3238/32 41/3641/36 42/3542/35 43/3743/37 43/3743/37 46/4146/41
YDSYDS
41/38/341/38/3 41/38/341/38/3 41/38/341/38/3 43/40/343/40/3 43/40/343/40/3 46/44/446/44/4 46/44/446/44/4 48/46/448/46/4 48/46/448/46/4 49/46/449/46/4
53. York Digital Scroll [YDS]
Ceiling mounted Duct Type
High Static Pressure Duct Type
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 140140 200200 250250
VRVVRV
IIIIII
48/44/4248/44/42 48/44/4248/44/42 53/50/4753/50/47 53/50/4753/50/47 53/50/4753/50/47
YDSYDS 33/31/2933/31/29 33/31/2933/31/29 34/32/3034/32/30 39/37/3539/37/35 41/39/3741/39/37 42/40/3842/40/38 43/41/3943/41/39 43/41/3943/41/39 44/42/4044/42/40 48/4548/45 48/4548/45
54. York Digital Scroll [YDS]
Ceiling Suspended
Ceilling & Floor Type
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 140140 --
VRV IIIVRV III 36/3136/31 39/3439/34 45/3745/37
YDSYDS
43/41/343/41/3 43/41/343/41/3 43/41/343/41/3 43/41/343/41/3 45/43/445/43/4 45/43/445/43/4 47/46/447/46/4 47/46/447/46/4
55. York Digital Scroll [YDS]
Wall Mounted
Type
Wall Mounted Type
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 200200 250250
VRVVRV 35/2935/29 36/2936/29 37/2937/29 39/3439/34 42/3642/36 46/3946/39
YDSYDS
46/44/446/44/4 46/44/446/44/4 46/44/446/44/4 46/44/446/44/4 48/46/448/46/4 48/46/448/46/4 50/49/450/49/4 50/49/450/49/4
56. York Digital Scroll [YDS]
Floor Standing & Concealed F
Floor Standing & Concealed Floor Standing
NOISE OF FCU
capacitycapacity
[hp][hp]
PRODUCTPRODUCT
2020 2525 31.2531.25 4040 5050 62.562.5 8080 100100 125125 200200 250250
VRV IIIVRV III 35/3235/32 35/3235/32 35/3235/32 38/3338/33 39/3439/34 40/3540/35
YDSYDS
42/39/342/39/3 42/39/342/39/3 42/39/342/39/3 46.43/346.43/3 46/43/346/43/3
60. Controls Controls
Advanced user friendly Touch
Screen (i-Touch) with superior
functions with programmable
schedule and interlocking.
York Intelligent Network Air-
condition control & monitor
system
DAIKIN VRV Digital Scroll
i-Touch
61. Stand Alone Controls Stand Alone Controls
I-Touch can be interfaced via
internet and accessed from a
remote PC (web browser
enable)
Not possible to be accessed
via internet.
INTERNET INTERNET
DAIKIN VRV Digital Scroll
62. Light
Fan
Pump
Fire alarm
Electricity
measurement
Daikin Central
Air Conditioning
System
DAM602B51
Ai unit
Dio unit
DIII-NET
DIII-NET
DIII-NET
DIII-NET
Sub PC
Ethernet
Web Access
Intranet/Internet
Web Access
Via Internet
Air Conditioning
Network Service System
(Optional Maintenance Service)
VRV System
HRV
Local monitoring
& control
Malfunction
report by E-Mail
Ⅲ
BMS
63. Engineering & Service TeamEngineering & Service Team
MORE THAN 20 YEAR EXPERIENCEMORE THAN 20 YEAR EXPERIENCE
How does it change the refrigerant flow? It changes the emission quantity of the refrigerant from the compressor. ① Compression is controlled ②Rpm is controlled In order not to compress, refrigerant gas is allowed to escape through things such as the solenoid valve. Because of the changes in the rotary speed of the compressor motor, the flow is changed. どのようにして冷媒循環量を変えるか? 圧縮機からの冷媒の吐出量を変化させる。 ① 圧縮を制御する ②回転数を制御する 圧縮しないように電磁弁などで冷媒ガスを逃がす。 圧縮機モーターの回転速度を変化させることで、流量を変化させる。
In the case of: Digital Scroll DC Inverter Scroll Full capacity High efficiency due to low compression loss High efficiency despite more compression loss due to high revolution rate, because DC motor is very efficient Medium capacity Low efficiency due to high compression loss Both compressor and motor have small loss and are efficient in energy conservation. Low capacity Compression loss is quite high because continuous Motor efficiency decreases but the DC motor’s efficiency decrease is small. Thus operation is difficult ( especially in heating) efficiency is achieved. デジタルスクロール DCインバータースクロール 最大能力時 圧縮ロス少なく高効率 高回転による圧縮ロス多いがDCモータ効率が高いので高効率 中間能力時 圧縮ロス多く、効率低い 圧縮、モータ共にロス少なく、高効率省エネ 最小能力時 圧縮ロス極めて多く連続運転が難しい。 モータ効率低下するが、DCモーターは効率低下が少なく、高効率 (特に暖房運転)
Digital Scroll DC Inverter Scroll Noise As low as Standard Type because of a fixed revolution rate. Our scrolls are designed to be low noise and high revolution. Weight Depends on the maximum ability because of a fixed revolution rate. Smaller, light-weight mechanism because max ability is gained by higher revolution. Structure Complicated mechanical structure Simple mechanical structure デジタルスクロール DCインバータースクロール 騒音 回転数一定なのでメカ騒音は標準機並み 高速回転する当社スクロールは低騒音設計のため静粛 重量 回転数一定なので最大能力に合わせた母体サイズ 最大能力は高速回転で得るため、小さい母体サイズ、軽量 構造 基本的に複雑なメカ構造 シンプルなメカ構造
Refrigerant flow Control with Load-Sensitive and High Response Speed Because the motor works with a constant speed, it is not efficient from an energy-saving viewpoint. Because of the solenoid valve, response is not instantaneous. Not smooth resulting in heavy mechanical burden. Mechanically complicated →cause of breakdown. 負荷に応じた滑らかで、応答速度の速い冷媒流量制御 モーターが一定速で回るため省エネ的見地から好ましくない 電磁弁による制御のため要求に即座に答えられない。 滑らかでなく、機械的に大きな負荷がかかる。 機械的に複雑になる→故障の原因
It is possible to control the motor speed directly. With electronic control it respond to request instantaneously. Simple structure - Compressor is the only mechanical part . モーターの回転を直接制御する事が出来る。 電子制御のため要求に即座に答えることが出来る。 機械的にはコンプレッサーのみで単純な構造である。
Inverter technology allows soft start control, which reduces starting current level and reduces installation costs. But digital compressor cannot achieve such a control, as compressor is starting at full load. インバーター圧縮機は回転を少しずつ上げるソフト起動で、起動電流を少なくできるが、デジタルコンプレッサーはフルロードで起動するため、起動電流が非常に大きい。
Outstanding feature of VRVIII is its wide and affluent model range. Not only increase the capacity up to 54 HP with 2 HP increment, but also we provide 2 series, compact and light weight Normal and high performance Energy saving Type to satisfy various customer’s demands. VRVⅢは5馬力~54馬力の広い能力レンジをほぼ2馬力きざみでカバ-するとともに、お客様の要望に応じて コンパクトで軽い標準シリ-ズと、省エネを重視したHタイプの2つのシリ-ズを用意しております。
As a new base model, 18 HP is added and system capacity is increased up to 54 HP in one system. システムを構成するベ-スユニットに18馬力の室外機を加えることにより、 最大54馬力の大容量を実現しました。
To cover large capacity, maximum piping length is extended up to 165 m and total length 1000 m. VRVⅡでは最大配管長150m,総配管長510mであったものが今回VRVⅢでは 最大配管長165m,総配管長1000mと許容冷媒配管を大幅に延長しました。
VRVIII also have excellent function in case of trouble. Operation data such as compressor speed, high and low pressure and running current of last 5 minutes before the trouble are stored to find the cause of the trouble. So you can take countermeasure quickly. 故障時には故障発生前5分間の運転デ-タ(圧縮機の回転数,高圧,低圧,等)を記憶していますので、 原因究明が早く迅速な対応が出来ます。
For plural units system, back up operation is provided for emergency operation. In case of trouble, alarm is indicated on a remote controller. Then the troubled unit is stopped and the other units are operated continuously by a remote controller. 複数室外機のシステムの場合、リモコンスイッチで故障した機械を停止し、 残りの機械の運転を続けられます。
We offer you 11 types and 79 models for various usage and interior design. また室内機は、部屋のインテリア,用途に応じて使い分けられるようカセット,ダクト,壁掛形等11種類形状、 79機種を用意しております。
Operation is very easy. All you have to do is to touch eyecon by a pen.