Flow rate
(l/h)
working
pressure
range
(bar)
water passage
dimensions
width-depth-length
(mm)
filtration
area
(mm2)
constant
K
Model inside Ø (mm) wall thickness (mm) outside Ø (mm) max. workingpressure(bar) KD
Wide filtration area to ensure optimal
performance even under harsh water
conditions
Injected silicon diaphragm
UniRam™ facets
Drippers technical data
Dripperlines technical data
Large , deep and wide cross-section
improves clogging resistance
Root physical barrier – improves resistance
to root penetration
PC system ensuring exact flow rate in
all field conditions
Injection molded
dripper construction, ensuring
uniform drippers and very low CV
*At working pressure range
16012, 16010, 16009
Anti-drain & Anti-siphonUniRam™ CNL
• TurboNet™ labyrinth assures wide water passage
• PC system for uniform flow rate from 1.0 - 4.0 bar
• Anti-siphon & self-flushing systems prevent dirt
penetration and improve clogging resistance
• Anti-drain (CNL) system for efficient pulse
irrigation, prevents water drainage and eliminates
need for refill
• Root physical barrier improves resistance to
clogging caused by root penetration
exponent*
X
For greenhouses, sub-surface, decidious & tree irrigation
shut-off
pressure
(bar)
Flow rate
(l/h)
Flow rate
(l/h)
Wall thickness
(mm)
Coil length
(m)
Distance between
drippers
(m)
Coil weight*
average
(kg)
Coils in a 40 feet
container
(units)
Total in a 40 feet
container
(m)
* According to drippers spacing
Packaging Data
Performance Data
Website: www.netafim.com
E-mail: postmaster@netafim.com
UniRam™ CNL 16012 • I.D. Ø 13.70 mm • Inlet pressure 3.0 bar
Max. lateral length (m) • spacing between drippers (m)
UniRam™ CNL
16012, 16010, 16009
Anti-drain & Anti-siphonUniRam™ CNL
For greenhouses, sub-surface, decidious & tree irrigation
Minimum pressure considered = 1.0 bar, calculated in a plain area.
For more information, please contact Netafim Technical Department or connect to our website at www.netafim.com
06-0707-DRP-PS-0049-EN
21.2
22.1
20.3
UniRam™ CNL 16010 & 16009 • I.D. Ø 14.10 mm • Inlet pressure 3.0 bar
Max. lateral length (m) • spacing between drippers (m)

Mais conteúdo relacionado

Mais procurados

waste water treatment.
waste water treatment.waste water treatment.
waste water treatment.aounali72
 
Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...
Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...
Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...India Water Portal
 
ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...
ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...
ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...ACQUEAU, EUREKA Cluster for Water
 
Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)
Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)
Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)Pure Aqua, Inc.
 
Terafil Water Filter S Khuntia Nov 11
Terafil Water Filter  S Khuntia Nov 11Terafil Water Filter  S Khuntia Nov 11
Terafil Water Filter S Khuntia Nov 11khuntias
 
Enzotech web site Presentation
Enzotech web site PresentationEnzotech web site Presentation
Enzotech web site Presentationenzotechslides
 
Basic Difference Between Pipes and Tubes
Basic Difference Between Pipes and TubesBasic Difference Between Pipes and Tubes
Basic Difference Between Pipes and TubesThe Piping Mart
 
Drain water heat recovery in a nutshell 102. How it works, different designs...
Drain water heat recovery in a nutshell 102.  How it works, different designs...Drain water heat recovery in a nutshell 102.  How it works, different designs...
Drain water heat recovery in a nutshell 102. How it works, different designs...Daniel Beauchemin
 
HVAC - Ducting system by Chidanand
HVAC - Ducting system by ChidanandHVAC - Ducting system by Chidanand
HVAC - Ducting system by ChidanandChidanandaChandrashe
 
MBRs the low down - prof. Simon Judd
MBRs the low down -  prof. Simon JuddMBRs the low down -  prof. Simon Judd
MBRs the low down - prof. Simon JuddBerghofKevin
 
The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...
The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...
The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...BerghofKevin
 
Marking and coding 22 03 2011
Marking and coding 22 03 2011Marking and coding 22 03 2011
Marking and coding 22 03 2011SHRIKANT ATHAVALE
 

Mais procurados (20)

waste water treatment.
waste water treatment.waste water treatment.
waste water treatment.
 
Unit 3
Unit 3Unit 3
Unit 3
 
Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...
Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...
Terafil Water filters_Sri Sai water treatment pvt ltd._Indovation 2015_23 Jan...
 
ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...
ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...
ACQUEAU Workshop Helsinki 2015_SMEs&wastewater session_Ville Hakala_Sofi Filt...
 
Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)
Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)
Containerized Membrane BioReactor Wastewater Treatment System (MBR-C)
 
Terafil Water Filter S Khuntia Nov 11
Terafil Water Filter  S Khuntia Nov 11Terafil Water Filter  S Khuntia Nov 11
Terafil Water Filter S Khuntia Nov 11
 
Enzotech web site Presentation
Enzotech web site PresentationEnzotech web site Presentation
Enzotech web site Presentation
 
Basic Difference Between Pipes and Tubes
Basic Difference Between Pipes and TubesBasic Difference Between Pipes and Tubes
Basic Difference Between Pipes and Tubes
 
SUNTEC DSA technical data_sp1000c_2014
SUNTEC DSA technical data_sp1000c_2014SUNTEC DSA technical data_sp1000c_2014
SUNTEC DSA technical data_sp1000c_2014
 
Drain water heat recovery in a nutshell 102. How it works, different designs...
Drain water heat recovery in a nutshell 102.  How it works, different designs...Drain water heat recovery in a nutshell 102.  How it works, different designs...
Drain water heat recovery in a nutshell 102. How it works, different designs...
 
Unit 3
Unit 3Unit 3
Unit 3
 
Eba 1123
Eba 1123Eba 1123
Eba 1123
 
Unit 4
Unit  4Unit  4
Unit 4
 
HVAC - Ducting system by Chidanand
HVAC - Ducting system by ChidanandHVAC - Ducting system by Chidanand
HVAC - Ducting system by Chidanand
 
MBRs the low down - prof. Simon Judd
MBRs the low down -  prof. Simon JuddMBRs the low down -  prof. Simon Judd
MBRs the low down - prof. Simon Judd
 
The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...
The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...
The role of AnMBR LEtm Anaerobic MBR in environmental improvements at the Gle...
 
Residential microfiltration catalogue
Residential microfiltration catalogueResidential microfiltration catalogue
Residential microfiltration catalogue
 
Residential microfiltration catalogue
Residential microfiltration catalogueResidential microfiltration catalogue
Residential microfiltration catalogue
 
Marking and coding 22 03 2011
Marking and coding 22 03 2011Marking and coding 22 03 2011
Marking and coding 22 03 2011
 
Water Presentation
Water PresentationWater Presentation
Water Presentation
 

Semelhante a UNIRAM-CNL Φ16

Dynasonics dfx datasheet badger meter doppler ultrasonic flow meter
Dynasonics dfx datasheet badger meter doppler ultrasonic flow meterDynasonics dfx datasheet badger meter doppler ultrasonic flow meter
Dynasonics dfx datasheet badger meter doppler ultrasonic flow meterENVIMART
 
SPC HDPE BROCHURE NEW
SPC HDPE BROCHURE NEWSPC HDPE BROCHURE NEW
SPC HDPE BROCHURE NEWLia Collatz
 
Utilizing Tubular UF Membrane Filtration for Wastewater Reuse
Utilizing Tubular UF Membrane Filtration for Wastewater ReuseUtilizing Tubular UF Membrane Filtration for Wastewater Reuse
Utilizing Tubular UF Membrane Filtration for Wastewater ReuseBerghof Membranes
 
Commercial Micron Fibreglass Filters 20 01 09
Commercial Micron Fibreglass Filters 20 01 09Commercial Micron Fibreglass Filters 20 01 09
Commercial Micron Fibreglass Filters 20 01 09bryan_goh
 
DRIPNET PC16390-17390-20390
DRIPNET PC16390-17390-20390DRIPNET PC16390-17390-20390
DRIPNET PC16390-17390-20390???????? ?.?.?.
 
999C1400_De NoraGWSBrochure_Sept15-EMAIL
999C1400_De NoraGWSBrochure_Sept15-EMAIL999C1400_De NoraGWSBrochure_Sept15-EMAIL
999C1400_De NoraGWSBrochure_Sept15-EMAILAlfredo Romanelli
 
Corrosion Resistant Level and Flow Measurement and Control Instruments
Corrosion Resistant Level and Flow Measurement and Control InstrumentsCorrosion Resistant Level and Flow Measurement and Control Instruments
Corrosion Resistant Level and Flow Measurement and Control InstrumentsM.S. Jacobs & Associates
 
Commercial_Filter_brochure_SinglePage_en.pdf
Commercial_Filter_brochure_SinglePage_en.pdfCommercial_Filter_brochure_SinglePage_en.pdf
Commercial_Filter_brochure_SinglePage_en.pdfKroeusnaMak
 
Harsha filters catalog
Harsha filters catalogHarsha filters catalog
Harsha filters catalogHarsha Filters
 
METZER ENGINEERING | New Production-Lines
METZER ENGINEERING  | New Production-LinesMETZER ENGINEERING  | New Production-Lines
METZER ENGINEERING | New Production-LinesMoran Yadid
 
Apie kapiliarinį drėkinimą ir tręšimą skystomis trąšomis
Apie kapiliarinį drėkinimą ir tręšimą skystomis trąšomisApie kapiliarinį drėkinimą ir tręšimą skystomis trąšomis
Apie kapiliarinį drėkinimą ir tręšimą skystomis trąšomisRamunas Rederis
 
Water Mist Systems - Akshay Jangam.
Water Mist Systems - Akshay Jangam. Water Mist Systems - Akshay Jangam.
Water Mist Systems - Akshay Jangam. Akshay Jangam
 
Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...
Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...
Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...A.T.E. Private Limited
 

Semelhante a UNIRAM-CNL Φ16 (20)

UniTechline_AS16_low
UniTechline_AS16_lowUniTechline_AS16_low
UniTechline_AS16_low
 
Dynasonics dfx datasheet badger meter doppler ultrasonic flow meter
Dynasonics dfx datasheet badger meter doppler ultrasonic flow meterDynasonics dfx datasheet badger meter doppler ultrasonic flow meter
Dynasonics dfx datasheet badger meter doppler ultrasonic flow meter
 
MATAF
MATAFMATAF
MATAF
 
SPC HDPE BROCHURE NEW
SPC HDPE BROCHURE NEWSPC HDPE BROCHURE NEW
SPC HDPE BROCHURE NEW
 
Utilizing Tubular UF Membrane Filtration for Wastewater Reuse
Utilizing Tubular UF Membrane Filtration for Wastewater ReuseUtilizing Tubular UF Membrane Filtration for Wastewater Reuse
Utilizing Tubular UF Membrane Filtration for Wastewater Reuse
 
Commercial Micron Fibreglass Filters 20 01 09
Commercial Micron Fibreglass Filters 20 01 09Commercial Micron Fibreglass Filters 20 01 09
Commercial Micron Fibreglass Filters 20 01 09
 
CATALOGE-PP AQUATECH.jpg
CATALOGE-PP AQUATECH.jpgCATALOGE-PP AQUATECH.jpg
CATALOGE-PP AQUATECH.jpg
 
DRIPNET PC16390-17390-20390
DRIPNET PC16390-17390-20390DRIPNET PC16390-17390-20390
DRIPNET PC16390-17390-20390
 
Diffuser1
Diffuser1Diffuser1
Diffuser1
 
999C1400_De NoraGWSBrochure_Sept15-EMAIL
999C1400_De NoraGWSBrochure_Sept15-EMAIL999C1400_De NoraGWSBrochure_Sept15-EMAIL
999C1400_De NoraGWSBrochure_Sept15-EMAIL
 
Corrosion Resistant Level and Flow Measurement and Control Instruments
Corrosion Resistant Level and Flow Measurement and Control InstrumentsCorrosion Resistant Level and Flow Measurement and Control Instruments
Corrosion Resistant Level and Flow Measurement and Control Instruments
 
LANDLINE 8mm
LANDLINE 8mmLANDLINE 8mm
LANDLINE 8mm
 
Commercial_Filter_brochure_SinglePage_en.pdf
Commercial_Filter_brochure_SinglePage_en.pdfCommercial_Filter_brochure_SinglePage_en.pdf
Commercial_Filter_brochure_SinglePage_en.pdf
 
Harsha filters catalog
Harsha filters catalogHarsha filters catalog
Harsha filters catalog
 
METZER ENGINEERING | New Production-Lines
METZER ENGINEERING  | New Production-LinesMETZER ENGINEERING  | New Production-Lines
METZER ENGINEERING | New Production-Lines
 
UNIBIOLINE
UNIBIOLINEUNIBIOLINE
UNIBIOLINE
 
Apie kapiliarinį drėkinimą ir tręšimą skystomis trąšomis
Apie kapiliarinį drėkinimą ir tręšimą skystomis trąšomisApie kapiliarinį drėkinimą ir tręšimą skystomis trąšomis
Apie kapiliarinį drėkinimą ir tręšimą skystomis trąšomis
 
Water Mist Systems - Akshay Jangam.
Water Mist Systems - Akshay Jangam. Water Mist Systems - Akshay Jangam.
Water Mist Systems - Akshay Jangam.
 
Radar Level Transmitters
Radar Level TransmittersRadar Level Transmitters
Radar Level Transmitters
 
Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...
Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...
Reduce your sludge and increase your profits with A.T.E. HUBER sludge managem...
 

Mais de ???????? ?.?.?. (11)

COMPANY PROFILE
COMPANY PROFILECOMPANY PROFILE
COMPANY PROFILE
 
MACHINE
MACHINEMACHINE
MACHINE
 
MixRite Catalgue
MixRite Catalgue   MixRite Catalgue
MixRite Catalgue
 
VENTURI
VENTURIVENTURI
VENTURI
 
ΒΑΛΒΙΔΑ ΚΑΘΑΡΙΣΜΟΥ
ΒΑΛΒΙΔΑ ΚΑΘΑΡΙΣΜΟΥΒΑΛΒΙΔΑ ΚΑΘΑΡΙΣΜΟΥ
ΒΑΛΒΙΔΑ ΚΑΘΑΡΙΣΜΟΥ
 
ΒΑΛΒΙΔΑ ΕΞΑΕΡΙΣΜΟΥ
ΒΑΛΒΙΔΑ ΕΞΑΕΡΙΣΜΟΥΒΑΛΒΙΔΑ ΕΞΑΕΡΙΣΜΟΥ
ΒΑΛΒΙΔΑ ΕΞΑΕΡΙΣΜΟΥ
 
PCJ (+12L H)
PCJ (+12L H)PCJ (+12L H)
PCJ (+12L H)
 
PCJ
PCJPCJ
PCJ
 
ARKAL SPIN KLIN 2''-2UNITS
ARKAL SPIN KLIN 2''-2UNITSARKAL SPIN KLIN 2''-2UNITS
ARKAL SPIN KLIN 2''-2UNITS
 
ARKAL SPIN KLIN 2''
ARKAL SPIN KLIN 2''ARKAL SPIN KLIN 2''
ARKAL SPIN KLIN 2''
 
ARKAL-2
ARKAL-2ARKAL-2
ARKAL-2
 

UNIRAM-CNL Φ16

  • 1. Flow rate (l/h) working pressure range (bar) water passage dimensions width-depth-length (mm) filtration area (mm2) constant K Model inside Ø (mm) wall thickness (mm) outside Ø (mm) max. workingpressure(bar) KD Wide filtration area to ensure optimal performance even under harsh water conditions Injected silicon diaphragm UniRam™ facets Drippers technical data Dripperlines technical data Large , deep and wide cross-section improves clogging resistance Root physical barrier – improves resistance to root penetration PC system ensuring exact flow rate in all field conditions Injection molded dripper construction, ensuring uniform drippers and very low CV *At working pressure range 16012, 16010, 16009 Anti-drain & Anti-siphonUniRam™ CNL • TurboNet™ labyrinth assures wide water passage • PC system for uniform flow rate from 1.0 - 4.0 bar • Anti-siphon & self-flushing systems prevent dirt penetration and improve clogging resistance • Anti-drain (CNL) system for efficient pulse irrigation, prevents water drainage and eliminates need for refill • Root physical barrier improves resistance to clogging caused by root penetration exponent* X For greenhouses, sub-surface, decidious & tree irrigation shut-off pressure (bar)
  • 2. Flow rate (l/h) Flow rate (l/h) Wall thickness (mm) Coil length (m) Distance between drippers (m) Coil weight* average (kg) Coils in a 40 feet container (units) Total in a 40 feet container (m) * According to drippers spacing Packaging Data Performance Data Website: www.netafim.com E-mail: postmaster@netafim.com UniRam™ CNL 16012 • I.D. Ø 13.70 mm • Inlet pressure 3.0 bar Max. lateral length (m) • spacing between drippers (m) UniRam™ CNL 16012, 16010, 16009 Anti-drain & Anti-siphonUniRam™ CNL For greenhouses, sub-surface, decidious & tree irrigation Minimum pressure considered = 1.0 bar, calculated in a plain area. For more information, please contact Netafim Technical Department or connect to our website at www.netafim.com 06-0707-DRP-PS-0049-EN 21.2 22.1 20.3 UniRam™ CNL 16010 & 16009 • I.D. Ø 14.10 mm • Inlet pressure 3.0 bar Max. lateral length (m) • spacing between drippers (m)