  1. 1. RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM SUBMITTED BY : ROHAN VERMA SUBMITTED TO : DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING BIRLA INSTITUTE OF TECHNOLOGY, MESRA
  2. 2. RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LIMITED • Rajasthan Rajya Vidyut Prasaran Nigam Limited (RVPN) a company under the Companies Act, 1956 and registered with Registrar of Companies as "RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LIMITED" vide No. 17-016485 of 2000-2001 (Corporate Identity Number (CIN) : U40109RJ2000SGC016485) with its Registered Office at VIDYUT BHAWAN, JYOTI NAGAR, JAIPUR-302005 has been established on 19 July, 2000 by Govt. of Rajasthan under the provisions of the Rajasthan Power Sector Reforms Act, 1999 as the successor company of RSEB. The RERC has granted RVPN a license for transmission and bulk supply vide RERC/Transmission and Bulk Supply License 4/2001 dated 30.4.2001 to function as Transmission and Bulk Supply Licensee in the State. • RVPN provides the pathway for power within whole of Rajasthan. RVPN owns, builds, maintains and operates the high- voltage electric transmission system that helps to keep the lights on, businesses running and communities strong. RVPN also owns the shared generating projects as representative of erstwhile RSEB.
  3. 3. RVPNL aim is to provide reliable electric transmission service to these customers. As a public utility whose infrastructure serves as the link in transporting electricity to millions of electricity users, RVPN has following duties and responsibilities: • Intra state transmission of electricity through Intra-State Transmission System; • New creation of EHV lines and Grid Sub Stations of 765 kV/400 kV/220 kV/132 kV rating including their maintenance and augmentations; • Planning and co-ordination relating to intra-state transmission with all concerned agencies such as CTU, State Govt., generating companies, licensees, Regional Power Committees etc. • Ensuring development of an efficient, coordinate and economical system of intra-state transmission of electricity from generating stations to Load Centers. AIM:
  4. 4. • GSS - GRID SUB STATION : A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels. A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. • Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control • The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. INTRODUCTIO N
  5. 5. 220 kv GSS, Kunda ki Dhani , Jaipur • The 220 KV GSS is situated in KUNDA ki Dhani, Jaipur. In the GSS single main and auxillary scheme is used. There are total three incoming feeder and many outgoing feeders which are mentioned in the next section. • The GSS step down the voltage level from 220KV to 132 KV and 132 KV to 33 KV or 11 KV in different manner. • There are three bus bar arrangement, main bus bar used at a time and auxillary bus bar are connected through bus coupler. In case of main bus or other equipment are out of order or other maintenance purpose than supply should be given through auxiliary bus bar without interruption in supply.
  6. 6. FEEDERS : Incoming Feeders: • 220 KV PGCIL-KKD • 132 KV KUKAS-KKD 1st • 132 KV KUKAS-KKD 2nd Outgoing Feeders: • 220 KV KKD- KUKAS • 132 KV KKD-PURANGHAT • 33KV • Achrol • Amber • Bund Gate 1 • Bund Gate 2 • JDA • Hotel Indana • 11 KV Natata • Kunda water works • Kukas
  7. 7. BUS BARS : • Bus bars are common electrical component through which a large number of feeders operating at some voltage have to be connected. • Electrical Busbar consists the number of lines electrically, which are operating at the same voltage and frequencies. Generally, copper or aluminum conducting material is used in the construction of bus bars.
  8. 8. POWER TRANSFORMER: • The Power transformer is one type of transformer that is used to transmit electrical energy in any component of the electronic or electrical circuit between the distribution primary circuits and the generator. These transformers are utilized in distribution networks to interface step down and step up voltages. The usual form of power transformer is fluid immersed, and the life cycle of these instruments is approximately 30 years. Power transformers can be divided into three types according to the ranges. They are large power transformers, medium power transformers, and small power transformers.
  9. 9. FIRE PROTECTION SYSTEM: • Transformer fire is a fearsome thing to experience and witness. Transformers are of many sizes and are found at power stations, electricity grid distribution centers and near our homes. Nevertheless, they pose a serious and grave situation when they catch fire. According to the firefighting professionals, handling such cases is one of the toughest scenarios that they can handle. • Major causes of fire in the transformer are Excessive heating, severe Short Circuits, Faulty coils and Oil leakage. So if any of the following factors are at play then chances of a transformer catching fire become big.
  10. 10. REMOTE TERMINAL UNITS: • The RTU is a microprocessor-based device that interfaces with a SCADA system by transmitting telemetry data to the master station and changing the state of connected switchgear based on control messages received from the master station or commands generated by the RTU itself. The RTU provides data to the master station and enables the master station to issue controls to the field equipment. Typical RTUs have physical hardware inputs to interface with field equipment and one or more communication ports.
  11. 11. SINGLE LINE DIAGRAM OF KKD GSS
  12. 12. CONCLUSION : • We think that our training was successful and we think that the 220KV sub- station at RVPN, KUNDA KI DHANI ,KUKA, JAIPUR is an excellent training centre for inquisitive emerging electrical engineers to learn about the transmission and distribution of high voltage electricity and all other protective devices. In the training session we came to know about the fundamentals of power system which may be quite useful for our fore coming studies.
  13. 13. THANK YOU

×