O slideshow foi denunciado.
Seu SlideShare está sendo baixado. ×

VSD by Sandeep Sengar

Anúncio
Anúncio
Anúncio
Anúncio
Anúncio
Anúncio
Anúncio
Anúncio
Anúncio
Anúncio
Anúncio
Anúncio

Confira estes a seguir

1 de 12 Anúncio

Mais Conteúdo rRelacionado

Diapositivos para si (20)

Semelhante a VSD by Sandeep Sengar (20)

Anúncio

Mais recentes (20)

VSD by Sandeep Sengar

  1. 1. PRESENTED BY :- SANDEEP SENGAR VENTRICULAR SEPTAL DEFECT
  2. 2. Ventricular septal defect (VSD), is a hole between your heart’s lower chambers, or ventricles that allow shunting of blood between the left and the right ventricles. The defect can occur anywhere in the muscle that divides the two sides of the heart. It is most common congenital cardiac anomaly in children and is the second most common congenital abnormality in adults.
  3. 3. Types Of VSD MUSCULA R VSD CONAL SEPTAL VSD PERI MEMBRANO US VSD ATRIO VENTRICUL R CANAL VSD
  4. 4. ACQUIREDCONGENITAL CAUSE Congenital heart defect ,present at birth can be see nearly 2 per 1000 live births. 1 Chest Trauma 2 Myocardial Infection Well known cause
  5. 5. VSD In 2D Echo The VSD may be small or large in size and single or multiple. The septal defect may be in the upper membranous portion (base) or in the lower muscular septum (apex). An infundibular (supracristal) VSD is located below the pulmonary valve (subpulmonary). An atrioventricular defect is located in the posterior portion of the septum around the tricuspid valve. An infundibular (supracristal) VSD is located below the pulmonary valve (subpulmonary). An atrioventricular defect is located in the posterior portion of the septum around the tricuspid valve. 2 3 1
  6. 6. No echo drop-out is observed if the defect is too small (< 3 mm) in size. If it is muscular in location, which shuts off during contraction in systole. 4 5 Multiple and small defects give the septum a “sieve-like” Or “Swiss-cheese” appearance.
  7. 7. VSD In Doppler Echo On color flow mapping, there is an abnormal flow pattern from the left to right ventricle The width of the color flow map approximates the size of The defect and helps in quantitative assessment. On continuous wave (CW) Doppler, a high velocity jet is identified across the septal defect High velocity jet with a high pressure gradient is suggestive of a small restrictive VSD in the muscular portion. With a significant volume of left-to-right shunt, there are features of right ventricular volume overload such as right ventricular dilatation beyond 23 mm and paradoxical motion of the IV septum. 1 3 2
  8. 8. Doppler Calculation The pulmonary artery pressure can be estimated from the transtricuspid peak flow velocity and pulmonary hypertension can be identified (see Pulmonary Hypertension). The quantity of left-to-right shunt can be estimated from the ratio between pulmonary and systemic stroke volume, which is the Qp : Qs ratio Qs is aortic outflow and Qp is pulmonary outflow. Qp is greater than Qs since a portion of the left ventricular output goes to the right ventricle 1 2 3
  9. 9. Cath Procedure Summary AMPLATZER® Duct Occluder Device used for VSD On the day of the procedure, pediatric cardiac anesthesiologist will place patient under sedation. He or she will be asleep during the procedure and not feel any pain. The anesthesiologist continues to monitor your child the entire time During the procedure Insert a catheter (a long, thin tube) into a blood vessel near your patient groin. Measure pressure and oxygen in heart and size of opening.2 Place the occluder onto a special catheter and advance it to the VSD opening in the patient heart. 1 3
  10. 10. Push the device out of catheter and implant it over the opening. The device fills the opening and seals it closed. Remove the catheter and close the incision. Transfer patient to Cardiac Procedure Recovery Unit (CPRU) ,patient will need to stay overnight in the hospital after the procedure. Patient will be transferred to the inpatient unit from the recovery room. Cardiologist do an echocardiogram the next morning to check the placement of the device. 4 6 5 7 The cardiologist will let you know when the patient can go home. 8
  11. 11. RISK 01 02 03 04 There is a small risk of heart rhythm problems Complications may occur with the closure device The catheter may break through a blood vessel INFECTIO N
  12. 12. Thanks

×