Explain the technique used in Flame-AAS that will prevent loss of sensitivity of analyte through ionization. (e) (3 marks)
Solution
In flame AAS ( Atomic Absorption Spectroscopy) the sample is ionised by heating by source of flame and the atoms of the sample gets converted into gaseous ground state which absorbs energy (light) of a particular wavelength from source of light and the amount of light absorbed tells about the concentration of the metal in the sample .
A nebulizer is used to spray the gaseous atoms (vapour) of the metal .
The source of light (hollow cathode lamp ) is most specific one and made up of the same metal which is to be analysed ang highly specific and thus maintain the sensitivity of the technique.
.

Explain the technique used in Flame-AAS that will prevent loss of sensitivity of analyte through ionization. (e) (3 marks)
Solution
In flame AAS ( Atomic Absorption Spectroscopy) the sample is ionised by heating by source of flame and the atoms of the sample gets converted into gaseous ground state which absorbs energy (light) of a particular wavelength from source of light and the amount of light absorbed tells about the concentration of the metal in the sample .
A nebulizer is used to spray the gaseous atoms (vapour) of the metal .
The source of light (hollow cathode lamp ) is most specific one and made up of the same metal which is to be analysed ang highly specific and thus maintain the sensitivity of the technique.
.

Anúncio
Anúncio

Mais Conteúdo rRelacionado

Mais de rtodd432 (20)

Mais recentes (20)

Anúncio

Explain the technique used in Flame-AAS that will prevent loss of sens (1).docx

  1. 1. Explain the technique used in Flame-AAS that will prevent loss of sensitivity of analyte through ionization. (e) (3 marks) Solution In flame AAS ( Atomic Absorption Spectroscopy) the sample is ionised by heating by source of flame and the atoms of the sample gets converted into gaseous ground state which absorbs energy (light) of a particular wavelength from source of light and the amount of light absorbed tells about the concentration of the metal in the sample . A nebulizer is used to spray the gaseous atoms (vapour) of the metal . The source of light (hollow cathode lamp ) is most specific one and made up of the same metal which is to be analysed ang highly specific and thus maintain the sensitivity of the technique.

×