2. Overview of New Features
• Integration of Nonin 3150 WristOx
What you’ll see
Reports
• Express Issue
Automatically issues recorder(s) with one click
Scheduled to patient for default of two days (inventory
management)
• Automated Interpretation Text
SleepImage will automatically include a paragraph on the
report that summarizes the results of the study.
The Only Simple and Objective Measure of Sleep Quality
3. Issuing to a Patient
• During the Issue process simply connect both the
SleepImage recorder and the Oximeter to the
computer
• Make sure you check the correct button on the
schedule screen
The Only Simple and Objective Measure of Sleep Quality
4. Issuing cont.
• During the Issue process the window will tell you
that both an Oximeter and SleepImage recorder
are being issued to the patient.
The Only Simple and Objective Measure of Sleep Quality
5. Upload
• Connect both recorders and select Upload.
• A screen will give you a summary of the tests
The Only Simple and Objective Measure of Sleep Quality
6. Example of Study With Oximetry
The Only Simple and Objective Measure of Sleep Quality
7. Integration of WristOx cont’d
• SpO2 information
can now be viewed
under the CPC
Spectrogram with
Actigraphy, Body
Position and Snore.
The Only Simple and Objective Measure of Sleep Quality
8. Integration of WristOx cont’d
Double click on the area
of interest, marked by the
blue indication bar
The Only Simple and Objective Measure of Sleep Quality
9. Integration of WristOx cont’d
Signals can be
viewed in 10s,
30s, 1m or 4m
windows
4m windows
reveal relationship
between Oximetry,
snore and
respiratory effort
The Only Simple and Objective Measure of Sleep Quality
10. Integration of WristOx cont’d
• Select the Report tab to view the report
• Choose type of report: Short, Comprehensive, or Multi-Night
• Select Oximetry from the Additional Display drop down
The Only Simple and Objective Measure of Sleep Quality
11. Integration of WristOx cont’d
An adjunct to the
report will include a
summary of the
SpO2 data in one
hour strips
The Only Simple and Objective Measure of Sleep Quality
12. Express Issue
1. Go to Patient Page
2. Connect the Sleep Recorder and/or Oximeter to the PC
3. Highlight the patient
4. Select Issue
The Only Simple and Objective Measure of Sleep Quality
13. Synch Button
• The clock of the recorder automatically synchs with the computer
when the recorders are issued
• If the batteries are removed the actual date/time may be lost
• To synchronize the recorder connect the recorder, go to the
Recorder page, and select Sync
The Only Simple and Objective Measure of Sleep Quality
14. Automated Interpretation Text
• While viewing patient study, select the Interpretation icon on the top
left of the screen
The Only Simple and Objective Measure of Sleep Quality
15. Automated Interpretation Text
• Select the Automated Text checkbox, and a summary of the
results will automatically populate. Select Save Interpretation
• Add or edit additional comments as required
The Only Simple and Objective Measure of Sleep Quality
17. Patient Detail Page
• Highlight Patient, select Data
• Select Patient Detail tab
The Only Simple and Objective Measure of Sleep Quality
18. Patient Detail Screen
• Select Add
• Enter Patient Height and Weight to automatically calculate BMI
• Select Epworth or Stop-Bang to enter subjective data from Patient
The Only Simple and Objective Measure of Sleep Quality
19. Patient Detail Screen
• Assign a study associated with the information
The Only Simple and Objective Measure of Sleep Quality
20. Why is this important? Trending!
• Select the Trends tab
• Select the dates you wish to compare data for
• Select the parameters you wish to compare over time
The Only Simple and Objective Measure of Sleep Quality
23. Best Practices
Press the button before giving recorder to patient
Batteries last about 90 hours but check the battery light
Application Instructions to patient:
clean/dry application area
loose EKG cable (exact placement not required),
sleep with garment over recorder
green light will be very dim, not to disrupt sleep but
recorder will automatically start recording
remove and discard electrode after use
The Only Simple and Objective Measure of Sleep Quality
25. FAQ’s
• Unable to click on or view the Upload or Issue button
Ensure SleepImage Manager is installed
Automatic Adobe Updates can cause this. See Support
Page for instructions also depends on the browser
• No Data message when uploading
Connect the sleep recorder to the PC
Open folder on your computer called M1-CXXXXXX (will
be recognized as a thumb drive on PC)
Open the Identity.DAT folder with Notepad
Look for DataFileUsed line – if this number = 0, there is
no data on the recorder (due to mis-application or
batteries). If the number is >0 you have data
The Only Simple and Objective Measure of Sleep Quality
26. Open Q&A
Please type your Technical
questions in the Chat Section
Please reserve Clinical questions for
the Clinical Spreecast coming soon
The Only Simple and Objective Measure of Sleep Quality